1-Emergency Generators for Mountain Branch Buildings Plan Set November 2026.pdf

PDF 2 MB Posted

Attached to
Emergency Generators for Mountain Branch Buildings
Solicitation number
US.261067
Issued by
Clearfield County, Pennsylvania

About this file

This is an Emergency Generators for Mountain Branch Buildings Plan Set prepared by Herbert, Rowland & Grubic, Inc. for the Houtzdale Municipal Authority in Clearfield County, Pennsylvania. The project involves furnishing and installing emergency generators and accessories at three groundwater sources—Well 4, Well 5, and Well 10—located on the Owner's Mountain Branch watershed. Contract 26-04 covers electrical construction work for this initiative. Bids for the project will be received through the PennBid program until Monday, December 21, 2026 at 12:00 PM local time, at which point bids will be opened and read. The plan set contains electrical drawings and specifications indexed for November 2026, including location maps, electrical notes and symbols, proposed plans and details for each well, ductbank sections and schedules, existing and proposed power one-line diagrams, control one-line diagrams for automatic transfer switches and generator control panels, remote terminal unit control diagrams with I/O schedules, and detailed construction drawings for gravel ductbanks, grounding counterpoises, conduit entries, equipment pads, generator pads, and electric handholes.

Bid security in the form of a certified check or bid bond is required in an amount not less than 10% of the bid. All inquiries regarding the meaning or intent of the bidding documents must be submitted through PennBid in accordance with the Instructions to Bidders; telephone inquiries are not acceptable. Bidding documents may be downloaded from the designated PennBid website at https://pennbid.bonfirehub.com/, and prospective bidders are urged to register as plan holders. All official notifications, addenda, and other bidding documents will be offered only through the designated website, and neither the Owner nor Engineer will be responsible for documents obtained from other sources. The project funding source and contract award date are not specified in this plan set document.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EMERGENCY GENERATORS FOR

MOUNTAIN BRANCH BUILDINGS

FOR

HOUTZDALE MUNICIPAL AUTHORITY

CLEARFIELD COUNTY, PENNSYLVANIA

DRAWING INDEX

NOVEMBER 2026

HERBERT, ROWLAND & GRUBIC, INC.

2568 PARK CENTER BLVD.

STATE COLLEGE, PA 16801

814. 238.7117 | hrg-inc.com

CONTRACT 26-04: ELECTRICAL CONSTRUCTION

LOCATION MAP

D A

T E

R E

V

IS

IO

N

S

N O

D

E S

C R

IP

T

IO

N

F O

R

HERBERT, ROWLAND & GRUBIC, INC.

2568 PARK CENTER BLVD.

STATE COLLEGE, PA 16801

814.238.7117 | hrg-inc.com

K

IR

K S

T R

E E

T

H O

U T

Z D

A L

E , P

A

C L

E A

R F

IE

L

D C

O U

N T

Y

P E

N N

S Y

L V

A N

IA

E M

E R

G E

N C

Y G

E N

E R

A T

O R

S F

O R

M O

U N

T A

IN

B

R A

N C

H B

U

IL

D

IN

G S

H O

U T

Z D

A L

E M

U N

IC

IP

A L

A U

T H

O R

IT

Y

ELECTRICAL

NOTES,

ABBREVIATIONS AND

SYMBOLS

E-1 X

INSTRUMENT & FUNCTION TAGGING

PROCESS EQUIPMENT TAGGING

GENERAL NOTES:

TYPICAL ANNOTATION

HVAC

FIRE ALARM SYSTEM

CONDUIT FEEDERS AND BRANCH CIRCUITSLIGHTING

POWER

INTRUSION ALARM SYSTEM

PANELBOARDS

TELECOMMUNICATION

PROCESS & INSTRUMENTATION LEGEND

DUCTBANK SYMBOL KEY

INSTRUMENT IDENTIFICATION TABLE

SWITCHING

T E

R E

V

IS

IO

N

S

N O

D

E S

C R

IP

T

IO

N

F O

R

HERBERT, ROWLAND & GRUBIC, INC.

2568 PARK CENTER BLVD.

STATE COLLEGE, PA 16801

814.238.7117 | hrg-inc.com

K

IR

K S

T R

E E

T

H O

U T

Z D

A L

E , P

A

C L

E A

R F

IE

L

D C

O U

N

N N

S Y

L V

A N

IA

E M

E R

G E

N C

Y G

E N

E R

A T

O R

S F

O R

M O

U N

T A

IN

B

R A

N C

H B

U

IL

D

IN

G S

H O

U T

Z D

A L

E M

U N

IC

IP

A L

A U

T H

O R

IT

Y

ELECTRICAL

WELL TH-10

PROPOSED PLAN

AND DETAILS

E-2 X

WELL TH-10 ELECTRICAL DEMOLITION AND PROPOSED PLAN

WELL TH-10 DUCTBANK SECTIONS AND SCHEDULE

DUCTBANK A-A

DRAWING NOTES:

T E

R E

V

IS

IO

N

S

N O

D

E S

C R

IP

T

IO

N

F O

R

HERBERT, ROWLAND & GRUBIC, INC.

2568 PARK CENTER BLVD.

STATE COLLEGE, PA 16801

814.238.7117 | hrg-inc.com

K

IR

K S

T R

E E

T

H O

U T

Z D

A L

E , P

A

C L

E A

R F

IE

L

D C

O U

N

N N

S Y

L V

A N

IA

E M

E R

G E

N C

Y G

E N

E R

A T

O R

S F

O R

M O

U N

T A

IN

B

R A

N C

H B

U

IL

D

IN

G S

H O

U T

Z D

A L

E M

U N

IC

IP

A L

A U

T H

O R

IT

Y

ELECTRICAL

WELL TH-4

PROPOSED PLAN

AND DETAILS

E-3 X

WELL TH-4 DUCTBANK SECTIONS AND SCHEDULE

WELL TH-4 ELECTRICAL PROPOSED PLAN

DUCTBANK B-B

T E

R E

V

IS

IO

N

S

N O

D

E S

C R

IP

T

IO

N

F O

R

HERBERT, ROWLAND & GRUBIC, INC.

2568 PARK CENTER BLVD.

STATE COLLEGE, PA 16801

814.238.7117 | hrg-inc.com

K

IR

K S

T R

E E

T

H O

U T

Z D

A L

E , P

A

C L

E A

R F

IE

L

D C

O U

N

N N

S Y

L V

A N

IA

E M

E R

G E

N C

Y G

E N

E R

A T

O R

S F

O R

M O

U N

T A

IN

B

R A

N C

H B

U

IL

D

IN

G S

H O

U T

Z D

A L

E M

U N

IC

IP

A L

A U

T H

O R

IT

Y

ELECTRICAL

WELL TH-5

PROPOSED PLAN

AND DETAILS

E-4 X

WELL TH-5 ELECTRICAL PROPOSED PLAN

WELL TH-5 DUCTBANK SECTIONS AND SCHEDULE

DUCTBANK C-C

T E

R E

V

IS

IO

N

S

N O

D

E S

C R

IP

T

IO

N

F O

R

HERBERT, ROWLAND & GRUBIC, INC.

2568 PARK CENTER BLVD.

STATE COLLEGE, PA 16801

814.238.7117 | hrg-inc.com

K

IR

K S

T R

E E

T

H O

U T

Z D

A L

E , P

A

C L

E A

R F

IE

L

D C

O U

N

N N

S Y

L V

A N

IA

E M

E R

G E

N C

Y G

E N

E R

A T

O R

S F

O R

M O

U N

T A

IN

B

R A

N C

H B

U

IL

D

IN

G S

H O

U T

Z D

A L

E M

U N

IC

IP

A L

A U

T H

O R

IT

Y

ELECTRICAL

EXISTING AND

PROPOSED POWER

ONE-LINE DIAGRAMS

E-5 X

WELL TH-10 PROPOSED POWER ONE-LINE DIAGRAM WELL TH-4 PROPOSED POWER ONE-LINE DIAGRAM WELL TH-5 PROPOSED OWER ONE-LINE DIAGRAM

WELL TH-10 EXISTING POWER ONE-LINE DIAGRAM WELL TH-4 EXISTING POWER ONE-LINE DIAGRAM WELL TH-5 EXISTING POWER ONE-LINE DIAGRAM

DRAWING NOTE:

T E

R E

V

IS

IO

N

S

N O

D

E S

C R

IP

T

IO

N

F O

R

HERBERT, ROWLAND & GRUBIC, INC.

2568 PARK CENTER BLVD.

STATE COLLEGE, PA 16801

814.238.7117 | hrg-inc.com

K

IR

K S

T R

E E

T

H O

U T

Z D

A L

E , P

A

C L

E A

R F

IE

L

D C

O U

N

N N

S Y

L V

A N

IA

E M

E R

G E

N C

Y G

E N

E R

A T

O R

S F

O R

M O

U N

T A

IN

B

R A

N C

H B

U

IL

D

IN

G S

H O

U T

Z D

A L

E M

U N

IC

IP

A L

A U

T H

O R

IT

Y

ELECTRICAL

CONTROL ONE-LINE

DIAGRAMS

E-6 X

AUTOMATIC TRANSFER SWITCH

'ATS'

'ATS' CONTROL ONE-LINE DIAGRAM

GENERATOR CONTROL PANEL

'GEN'

'GEN' CONTROL ONE-LINE DIAGRAM

DRAWING NOTE:

REMOTE TERMINAL UNIT

'RTU-1'

'RTU-1' CONTROL ONE-LINE DIAGRAM

I/O LIST SCHEDULE

T E

R E

V

IS

IO

N

S

N O

D

E S

C R

IP

T

IO

N

F O

R

HERBERT, ROWLAND & GRUBIC, INC.

2568 PARK CENTER BLVD.

STATE COLLEGE, PA 16801

814.238.7117 | hrg-inc.com

K

IR

K S

T R

E E

T

H O

U T

Z D

A L

E , P

A

C L

E A

R F

IE

L

D C

O U

N

N N

S Y

L V

A N

IA

E M

E R

G E

N C

Y G

E N

E R

A T

O R

S F

O R

M O

U N

T A

IN

B

R A

N C

H B

U

IL

D

IN

G S

H O

U T

Z D

A L

E M

U N

IC

IP

A L

A U

T H

O R

IT

Y

ELECTRICAL

DETAILS

E-7 X

GD

GRAVEL DUCTBANK DETAIL

GC

GROUNDING COUNTERPOISE DETAIL

CE

CONDUIT ENTRY THRU WALL DETAIL

EP

EQUIPMENT PAD DETAIL

GP

GENERATOR PAD DETAIL

EH

ELECTRIC HANDHOLE DETAIL

E-SI-CV
Sheets and Views
CV
E-SI-1
Sheets and Views
1
E-SI-2
Sheets and Views
2
E-SI-3
Sheets and Views
3
E-SI-4
Sheets and Views
4
E-SI-5
Sheets and Views
5
E-SI-6
Sheets and Views
6
E-SI-7
Sheets and Views
7

File details come from the government source that posted it. Updated .