1. SOW Hi-Vac Industrial Vacuum Model 850.pdf
PDF 235 KB Posted
- Attached to
- Industrial Vacuum
- Solicitation number
- W911KF-24-Q-0029
About this file
This document is a Statement of Work (SOW) for the procurement of four (4) Hi-Vac Model 850 industrial vacuums for the Anniston Army Depot. The SOW establishes the requirements for new industrial grade vacuum systems to remove abrasive and tear down debris from production shops at the Anniston Army Depot. The key details include:
The vacuums must meet the following specifications: 50 horsepower motor, NEMA 4 control panel, two-stage material separation with continuous reverse pulse, and 5-inch material inlet. The contractor must also provide four 2-cubic yard hoppers, support stands with air lift assemblies, and safety features such as a broken bag detector, high temperature shutdown, and vacuum breaker. The contractor is responsible for shipping the equipment to the Anniston Army Depot and providing operator and maintenance manuals. The government will provide installation and unloading of the equipment. The purchase effort must be completed within 180 calendar days upon contract award, and the contractor shall provide a standard commercial warranty.
The related federal contract opportunity is solicitation number W911KF-24-Q-0029 for the Hi-Vac Model 850 Industrial Vacuum, issued by the Department of the Army Materiel Command Contracting Command Detroit Arsenal.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Hi-Vac Model 850 For Bldgs. 114, 400 Tear Down, 409, 433 Statement of Work
1.0 OBJECTIVE: Anniston Army Depot has a need to purchase a quantity of four (4) Hi-Vac Model 850 industrial vacuums for production debris removal.
2.0 SCOPE: This specification establishes a requirement for new industrial grade vacuum systems to remove abrasive and tear down debris from production shops at Anniston Army Depot. The purchase effort shall be completed within 180 calendar days upon contract award.
3.0 REQUIREMENTS:
3.1. Scope Change: The contractor shall not proceed with any verbal or written change(s) to the scope of work from sources other than the Contracting Officer, who will provide changes in writing.
3.2. The contractor shall provide and meet specifications for the following vacuum system, accessories, and quantities listed:
(4) ea. Hi-Vac Model 850s with 50 horsepower motor, NEMA 4 control panel, two stage material separation including continuous reverse pulse, and 5” material inlet.
(4) ea. 2 Cubic yard hopper.
(4) ea. Support stand with air lift assembly.
(4) ea. Safety features: Broken bag detector, high temperature shutdown, Hi- Vac vacuum breaker.
(4) ea. Accessories: 50’ 3” abrasion resistant work hose, 5” female camlock coupler, 5” male camlock coupler, 5”x3” hose adapter, 3” round aluminum nozzle.
3.3. The contractor shall provide shipping for all equipment items to Anniston Army Depot, Bldg 140.
3.4. The contractor shall provide three each compact disc and hard copies of all operator manuals and maintenance manuals for each vacuum.
3.5. The contractor shall provide standard commercial warranty.
3.6. The government will provide installation and unloading of equipment at Anniston Army Depot.