This document contains the Minimum and Specific Requirements for an Armed Forces Career Center lease opportunity in Deerfield Beach, FL. The U.S. Army Corps of Engineers is soliciting proposals for a commercial storefront or retail space between 1,492 to 1,865 gross square feet, with specific requirements including private offices, open workstation space, a testing/conference room, and a storage room. Common area requirements include restrooms and a janitorial closet. The space must have 24-hour access, secured parking for 4 government vehicles, and adequate parking for service members and visitors. The lease is for a 5-year term with government termination rights, and a full-service lease is preferred. Proposals are due by 4:00 PM on April 26, 2024, and the government will select a location based on the evaluation factors and lowest overall cost.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

- 1 -

Minimum and Specific Requirements

Armed Forces Career Center

Minimum Usable Square Footage: 1,492 SF

Maximum Usable Square Footage: 1,865 SF

Minimum Requirements for All Offices:

1. Secondary egress for office suite leading away from the main entry door.

2. 24-hour lighted or secured parking within the lessor’s premises for FOUR (4)

Government vehicles.

3. Adequate parking for Service member privately owned vehicles during working hours, as well as for office visitors.

4. 24-hour access to the leased spaces.

5. High-speed data service connection (Fiber is preferred) from the street to the building demarcation point.

Army Specific Requirements:

1. Private Offices: One (1) private office of 100 SF within each individual Armed Forces

Center; see specific requirements detailed within the construction specifications.

2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for 5 workstations of approximately 125 SF.

3. Testing/Conference Room: One (1) testing room of 80 SF with a window or a glass door facing the open area for test monitoring.

4. Storage Room: One (1) storage room of 80 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a communications board. An additional 40 SF shall be allocated if separate

CCTV/Security closet is required.

Minimum and Specific Requirements

- 2 -

Common Area Requirements:

1. Restrooms: A minimum of TWO (2) located within the suite; each restroom meeting

ADA specifications built to accommodate at least one at one time.

2. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications. The janitorial closet must be located in the common area.