1 - Bill of Material for RFQ-NIAID-23-2176128.xlsx
XLSX spreadsheet 12 KB Posted
- Solicitation number
- RFQ-NIAID-23-2176128
About this file
This document is a bill of material for RFQ-NIAID-23-2176128 seeking a Luna FX7 automated cell counter or equal product from Logos Biosystems. The National Institutes of Health National Institute of Allergy and Infectious Diseases requires a high-throughput cell counting system that can simultaneously evaluate 8 human samples and determine cell counts with 1.5% accuracy for samples over 5 microliters. The system must include quality control software to validate results, have at least 256GB of storage, and come with a one year manufacturer warranty. It should be compatible with Countwire software and 21 CFR Part 11 compliance. The instrument dimensions cannot exceed 245 x 280 x 240 mm. Offers must meet the salient characteristics and clearly identify any proposed modifications. The contracting officer will evaluate equal products based on information provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 4 - FAR 52.212-5 MARCH 2023.docx | DOCX document | |
| IPP collector-quick-reference-guide.pdf | ||
| 4 - HHSAR 352.docx | DOCX document | |
| 4 - HHSAR 352.232-71.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| RFQ-NIAID-23-2176128 |
| Brand Name or equal |
| Logos Biosystems |
| https://logosbio.com/luna-fx7/ |
| # | Description | Catalog | Qty |
| 1 | Luna FX7 Automated Cell Counter | L70001 | 1 each |
| 2 | Shipping | 1 each | |
| FOB Shipping destination: Bethesda, MD 20892 | |||
| Country of Origin must be included for each line item on quote | |||
| Quotes for equal products must include details that demonstrate in detail being an equal product in order to be considered. | |||
| Quotes will be evaluated per FAR Part 25 | |||
| Quote must list items in the exact order as this bill of material | |||
| Must be compatible with Luna FX7 Automated Cell Counter | |||
| 1. A Luna FX7 automated cell counter system that is able to evaluate human samples and accurately determine the number of cells. | |||
| 2. The cell counting system must be high-throughput and can evaluate 8 human subject samples simultaneously. | |||
| 3. The cell counting system must be accurate within 1.5% cell volume for samples greater than 5 microliters. | |||
| 4. The cell counting system must have quality control software that validate the results of the cell count processed. | |||
| 5. The cell counting system should have at least 256GB of storage. | |||
| 6. The cell counting system should come with a one year manufacturer warranty. | |||
| 7. compatible with Countwire software and - 21 Cfr Part 11 Compliance | |||
| Size Requirements: Instrument cannot exceed these dimensions: | |||
| 245 x 280 x 240 mm |
52.211-6 Brand Name or Equal.
Brand Name or Equal (Aug 1999)
(a) If an item in this solicitation is identified as "brand name or equal," the purchase description reflects the characteristics and level of quality that will satisfy the Government’s needs. The salient physical, functional, or performance characteristics that "equal" products must meet are specified in the solicitation.
(b) To be considered for award, offers of "equal" products, including "equal" products of the brand name manufacturer, must-
(1) Meet the salient physical, functional, or performance characteristic specified in this solicitation;
(2) Clearly identify the item by-
(i) Brand name, if any; and
(ii) Make or model number;
(3) Include descriptive literature such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the Contracting Officer; and
(4) Clearly describe any modifications the offeror plans to make in a product to make it conform to the solicitation requirements. Mark any descriptive material to clearly show the modifications.
(c) The Contracting Officer will evaluate "equal" products on the basis of information furnished by the offeror or identified in the offer and reasonably available to the Contracting Officer. The Contracting Officer is not responsible for locating or obtaining any information not identified in the offer.
(d) Unless the offeror clearly indicates in its offer that the product being offered is an "equal" product, the offeror shall provide the brand name product referenced in the solicitation.
(End of provision) https://logosbio.com/luna-fx7/
File details come from the government source that posted it. Updated .