Sheet1

Bill of Materials for RFQ-NIAID-2132322-SB
Total Small Business Set-aside
New - OEM Brand Name Only
DAWN Ambient Multi-angle Light Scattering (MALS) with ASTRA software
https://www.infors-ht.com/en/shakers/incubator-shakers/multitron/
#DescriptionCatalogQty
1DAWN Ambient Seventh generation multi-angle light scattering instrumentWD31 each
2Optilab - Differential refractive index detector for standard HPLC/GPC/FPLC. Measures differential and absolute Refractive Index (dRI and aRI) with high sensitivity and dynamicWOP11 each
3ASTRA 8 software for characterization of macromolecules and nanoparticles by online multi-angle light scattering, refractometry and viscometryCK28001 each
4Technical SupportY-TECHSUPP1 each
5InstallationY-INSTALL21 each
6Shipping1 each
Warranty information must be included in quote
Estimated delivery time must be listed on the quote.
FOB Shipping destination: NIH/NIAID/Vaccine Research Center (VRC)
9 West Watkins Mill Road, Gaithersburg, MD 20878
Identification of the statutory authority permitting other than full and open competition
41 USC 1901(e)(2) and FAR Part 13.106-1(b): Brand Name Only
Due to continuity protocols, as well as compatibility, the DAWN Ambient brand Multi-angle Light Scattering (MALS) with ASTRA software is required. Experiments in process have been conducted using this instrument and the lab must continue to use this brand through the life cycle of the study to avoid introducing outside variables resulting in corruption of our experiments. The Infors brand is required due to continuity, compatibility, size requirements.
Instrument Specifications - must be compatible with ASTRA 8 software.
Measurements
Molar Mass Range200 Da to 1 Gda
Molecular Size Range (Rg)≈ 10 to 500 nm, up to 1000 nm with shape-specific models
Molecular Size Range (Rh)In flow mode, 0.5 nm to 300 nm2; batch mode 0.5 nm to 1 μm (requires WyattQELS DLS module or DynaPro® NanoStar® + fiber optic connection).
Sensitivity10 ng of 100 kDa polystyrene in THF or 200 ng of BSA in PBS, assuming standard 7.8 mm x 300 mm SEC column
Fluidics
Mobile Phase CompatibilityAll-solvent compatible (aqueous and organic). Wetted materials are 316 stainless steel, fused silica or F2 glass, and Kalrez.
Optics
Detectors
MALS DetectorsHigh-gain, high dynamic range photodiodes at 18 detection angles.
Auxiliary DetectorsLaser monitor for stabilization feedback; forward transmission monitor to correct signals for absorbing samples and to assess data quality.
Dynamic Range3,300,000:1
DLS Detector (optional)WyattQELS dynamic light scattering module installs directly inside the DAWN chassis. Alternatively, the optical fiber pickup of the DynaPro NanoStar cuvette-based DLS instrument or Mobius DLS-ELS instrument may be installed in the DAWN.
Laser Properties
Laser Wavelength658 nm ± 4 nm; 785 nm optional for use with fluorescing samples
Laser Power ControlProgrammable 10% to 100%
Flow CellsFused Silica, optimal for solvent refractive index less than 1.50; F2, optimal for solvent refractive index above 1.50
Temperature OptionsAmbient
Heated/Cooled (HC) -15 °C to +150 °C
Ultra-High-Temperature (UHT) ambient to +210 °C
Electronics
Analog Inputs4 differential analog inputs with 24 bit resolution. Input range -10 V to +10 V
Analog Outputs2 analog outputs from user selectable measurements channels -10 V to +10 V
Other Inputs/OutputsAlarm in, Alarm out/retransmit, Auto-Inject in, Auto inject contact closure retransmit, Recycle In/Out (operates Orbit™ recycle valve)
Computer InterfaceEthernet
Front Panel Display10.1" (257 mm), capacitive high-resolution screen with multi-touch functionality, displays signals, graphs, instrument settings and diagnostics
Dimensions58 cm (L) x 36 cm (W) x 26 cm (H)