1-Bid 26-68-3320 Kentmere Lift Station Modifications and Force Main Design Drawings.pdf
PDF 36 MB Posted
- Solicitation number
- 26-68-3320
- Issued by
- Fayette County, Georgia
About this file
This is a Site Development Plan and Design Drawing set prepared by Carollo Engineers, Inc. and Freese and Nichols, Inc. for the Forsyth County Department of Water and Sewer in Cumming, Georgia. The project encompasses modifications to the existing Kentmere Lift Station and installation of force main and gravity sewer infrastructure. Major components include modifications to pump control logic and wetwell control elevations with two new float switches; two new flow meter vaults with magnetic flow meters (6-inch and 8-inch), actuated plug valves, yard piping, and associated controls; approximately 20 linear feet of 8-inch ceramic epoxy lined ductile iron pipe (DIP) at the lift station site; 2,130 linear feet of 6-inch ceramic epoxy lined DIP force main; and 265 linear feet of 8-inch polyvinyl chloride (PVC) gravity sewer pipe with associated manholes, valves, and appurtenances. The project site is approximately 1.20 acres with 1.20 acres of disturbed area, located in Forsyth County and spanning from the Kentmere Lift Station along Carrick Road and Whitfield Avenue to terminates before Atlanta Highway. The non-mandatory pre-bid meeting is scheduled for 2:00 pm on Monday, June 22, 2026, at the Forsyth County Department of Water and Sewer, Kentmere LS, 3289 Glen Wallace Drive, Cumming, Georgia 30040. All work must be substantially completed within 485 calendar days from issuance of notice to proceed.
The design drawings indicate that all improvements must conform to Forsyth County Construction Standards and Specifications, with the contractor responsible for field verification of all existing utilities and site conditions prior to construction. The project includes stream buffer encroachments requiring a variance and impacts 2,660 square feet of stream buffer area. Contractor responsibilities include utility coordination through Utility Coordinator Manager Damon Stancil at 770-781-2165, compliance with local construction stormwater discharge regulations, protection of existing facilities and utilities, and stabilization of all disturbed areas within 48 hours or prior to expected rainfall events. The design includes detailed erosion and sediment control measures, with the contractor required to maintain all control devices and establish permanent vegetation before final project release, with responsibility for repairs extending twelve months after project acceptance.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
© 2024 Microsoft Corporation © 2024 Maxar ©CNES (2024) Distribution Airbus DS
FORSYTH COUNTY
DEPARTMENT OF WATER AND SEWER
KENTMERE LIFT STATION
MODIFICATIONS AND FORCE MAIN DESIGN
SITE DEVELOPMENT PLANS
VICINITY MAP
CONSULTING ENGINEERS:
MAY 2026
FSY24542
2500 Windy Ridge Parkway, Suite 1200 Atlanta, GA 30339 Phone - (404) 334-4310 Web - www.freese.com
Freese and Nichols, Inc.
Georgia Registered Engineering Firm
PEF-004433
Expires 06/30/2026
DEVELOPER/OWNER (24-HOUR CONTACT):
FORSYTH COUNTY DEPARTMENT OF WATER AND SEWER
110 EAST MAIN STREET, SUITE 150
CUMMING, GA 30040
DANIEL SHAW, P.E.
(470) 487-5873
KENTMERE FORCE MAINFORSYTH COUNTY BOARD OF COMMISSIONERS
KERRY HILL, DISTRICT 1
ALFRED JOHN, DISTRICT 2
TODD LEVENT, DISTRICT 3
MENDY MOORE, DISTRICT 4
LAURA SEMANSON, DISTRICT 5
FORSYTH COUNTY DEPARTMENT OF WATER AND SEWER
SCOTT ADAMS, P.E., DIRECTOR
REVISION LIST
NO. ISSUE BY DATE
1 100% FINAL DESIGN JCS 6/27/2025
2 SITE DEVELOPMENT PLANS JCS 5/15/2026
ATLANTA HIGHWAY
W
HI
TF
IE
LD
A
VE
Carollo Engineers, Inc.
Georgia Registered Engineering Firm
PEF-004701
Expires 06/30/2026
KENTMERE LIFT STATION
2500 Clean Water Court, Building A, Suite 300 Buford, GA 30519 Phone - (470) 422-7982 Web - www.carollo.com
MANHOLE AND
GRAVITY SEWER
CONNECT TO
EX MANHOLE
PROJECT NARRATIVE:
THE PROPOSED PROJECT CONSISTS OF MODIFICATIONS TO THE EXISTING
KENTMERE LIFT STATION AS WELL AS THE INSTALLATION OF FORCE MAIN AND
GRAVITY SEWER LOCATED IN FORSYTH COUNTY, GEORGIA. THE PROJECT BEGINS
AT THE KENTMERE LIFT STATION, FOLLOWS AN EXISTING EASEMENT TOWARDS
CARRICK ROAD, RUNS SOUTH ALONG CARRICK ROAD, CONTINUES SOUTH
ALONG WHITFIELD AVENUE, AND TERMINATES BEFORE ATLANTA HIGHWAY. THE
TOTAL AREA OF THE SITE IS APPROXIMATELY 1.20 ACRES. THE TOTAL DISTURBED
AREA IS 1.20 ACRES.
NOTES:
1. UTILITY PERMIT REQUIRED. CONTACT UTILITY COORDINATOR MANAGER
DAMON STANCIL AT 770-781-2165.
2. CONSTRUCTION WASTE MAY NOT BE BURNED OR BURIED AND MUST BE
TAKEN TO A STATE APPROVED LANDFILL.
3. PER UDC 10-1.13 OUTSIDE CONSTRUCTION SHALL BE LIMITED TO THE
HOURS OF 7:00 AM TO 7:00 PM MONDAY TO FRIDAY, 8:00 AM TO 6:00 PM
SATURDAY, AND THERE WILL BE NO OUTSIDE CONSTRUCTION ON SUNDAY.
SITE ACREAGE: 1.20 AC (52,270 SF)
DISTURBED ACREAGE: 1.20 AC (52,270 SF)
STREAM BUFFER IMPACT: 2,660 SF
5/15/2026
GENERAL NOTES
1. FOLLOWING NOTES ARE GENERAL AND APPLY TO ALL SHEETS OF THESE CONTRACT DOCUMENTS AS IF
THEY WERE WRITTEN IN THEIR ENTIRETY ON EACH SHEET.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE STARTING WORK AND SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY DISCREPANCIES. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING CONDITIONS INCLUDING LOCATION AND DIMENSIONS OF ALL EXISTING CONSTRUCTION AND UTILITIES. CONTRACTOR SHALL NOTIFY ENGINEER IF THERE IS A CONFLICT BETWEEN THE CONTRACT
DOCUMENTS AND EXISTING CONSTRUCTION BEFORE PROCEEDING WITH WORK.
3. UNLESS DETAILED, SPECIFIED, OR OTHERWISE INDICATED ON THE DRAWINGS, CONSTRUCTION SHALL BE AS INDICATED IN THE APPLICABLE TYPICAL DETAILS AND GENERAL NOTES. TYPICAL DETAILS SHALL APPLY
EVEN THOUGH NOT REFERENCED AT SPECIFIC LOCATIONS ON DRAWINGS.
4. WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR ANY PART OF WORK, DETAILS SHALL BE PER FORSYTH COUNTY DEPARTMENT OF WATER AND SEWER STANDARDS OR THE SAME AS FOR OTHER
SIMILAR WORK.
5. CONTRACTOR SHALL COMPLY WITH LOCAL CONSTRUCTION STORM WATER DISCHARGE REGULATIONS
AND REQUIREMENTS.
6. PRIOR TO EXCAVATION FOR NEW STRUCTURES, ELECTRICAL CONDUIT, FABRICATION OF NEW PIPING AND/OR OTHER PROPOSED UTILITIES, CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL EXISTING PIPING AND UTILITIES IN THE CONSTRUCTION AREA. THE CONTRACTOR SHALL TEMPORARILY RELOCATE CONFLICTING EXISTING UTILITIES AT TIE-IN/CONNECTION LOCATIONS AND REINSTALL THEM AS REQUIRED TO ELIMINATE THE CONFLICT AT NO ADDITIONAL COST TO THE
OWNER.
7. ALL PIPELINES SHALL HAVE A MINIMUM COVER OF 48" UNLESS THE COVER DEPTH IS
SPECIFICALLY INDICATED ON THE DRAWINGS. PIPES SHALL BE ROUTED AS SHOWN UNLESS MINOR REVISIONS ARE NECESSARY TO MISS EXISTING PIPES, STRUCTURES, ETC. CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING ALL FITTINGS AND ADAPTERS REQUIRED TO MAKE THE ROUTING CHANGES AT NO
ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL INCLUDE COST FOR THIS IN THE BID.
8. EXISTING FACILITY AND UTILITY INFORMATION SHOWN ON THE DRAWINGS WAS OBTAINED FROM AVAILABLE RECORDS OR ELECTRONIC FILES. NEITHER THE OWNER NOR ENGINEER ASSUMES ANY RESPONSIBILITY FOR FACILITIES AND UTILITIES NOT SHOWN OR NOT IN THE LOCATION SHOWN.
THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS, SIZES, MATERIAL TYPES, AND ELEVATIONS
SHOWN AROUND OR NEAR AREAS OF NEW CONSTRUCTION PRIOR TO START OF CONSTRUCTION.
9. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONARY MEASURES NECESSARY TO PROTECT FROM DAMAGE EXISTING FACILITIES AND UTILITIES SHOWN OR NOT SHOWN THAT ARE TO REMAIN IN PLACE.
ALL FACILITIES DAMAGED BY THE CONTRACTOR'S OPERATIONS SHALL BE EXPEDITIOUSLY REPAIRED
OR RECONSTRUCTED TO THE ORIGINAL OR BETTER CONDITION AT THE CONTRACTOR'S EXPENSE
WITHOUT ADDITIONAL COMPENSATION.
10. CONTRACTOR SHALL MAKE CONNECTIONS TO EXISTING PIPE, EQUIPMENT, ETC. AS REQUIRED AND SHALL PROVIDE ALL FITTINGS, ADAPTERS, AND APPURTENANCES REQUIRED TO MAKE THE CONNECTIONS.
PROVIDE ALL SUPPORTS REQUIRED FOR A RIGIDLY SUPPORTED COMPLETE AND WORKING SYSTEM.
11. ADJUST ALL VALVE BOXES, VAULTS, PULL BOXES, AND MANHOLES TO FINISHED GRADE UNLESS OTHER- WISE SHOWN OR DIRECTED. MANHOLES IN OPEN FIELDS SHALL BE SET TWELVE INCHES ABOVE FINISHED
GRADE AND VAULTS SHALL BE SIX INCHES ABOVE FINISHED GRADE.
12. CONTRACTOR SHALL VERIFY THAT PIPING SHOWN TO BE ABANDONED OR AS ABANDONED PREVIOUSLY IS NO LONGER IN SERVICE. LINES IN SERVICE SHALL BE MAINTAINED UNTIL NO LONGER REQUIRED BY
THE STATION.
13. ALL EXISTING PIPES THAT ARE TO BE ABANDONED IN PLACE OR REMOVED MAY NOT BE SHOWN.
WHERE PIPING IS TO BE ABANDONED AND MUST REMAIN IN SERVICE UNTIL COMPLETION OF OTHER PHASES OF WORK, AND IT CONFLICTS WITH NEW PIPING, TEMPORARILY RELOCATE PIPING AS REQUIRED
TO MAINTAIN SERVICE BY THE STATION.
14. CONTRACTOR SHALL REROUTE THE EXISTING WATER OR SEWER PIPING IF REQUIRED TO MISS THE
PROPOSED STRUCTURES. NATURAL GAS AND OTHER UTILITY RELOCATION IS NOT PERMITTED.
THE EXISTING PIPE SHALL REMAIN IN SERVICE UNTIL NEW PIPING IS READY TO BE PLACED INTO SERVICE.
DOWNTIME SHALL BE A MAXIMUM OF 2 HOURS, UNLESS SPECIFIED OR SHOWN OTHERWISE.
15. ALL SIDEWALKS SHALL MEET FORSYTH COUNTY DEPARTMENT OF WATER AND SEWER STANDARDS.
16. THE CONTRACTOR SHALL TAKE SPECIAL PRECAUTIONS IN THE VICINITY OF ANY OVERHEAD ELECTRIC LINES. CONTRACTOR SHALL ABIDE BY THE NATIONAL ELECTRIC CODE AND ANY REQUIREMENT BY THE
OWNER OF THE ELECTRIC LINES.
17. PROVIDE ALL SHEETING/SHORING REQUIRED TO PROTECT EXISTING STRUCTURES, PIPES AND FACILITIES.
18. CONTRACTOR SHALL VERIFY LOCATION OF ALL MECHANICAL AND ELECTRICAL ITEMS
BEFORE PLACING ANY STRUCTURAL STEEL OR CONCRETE. ALSO, STRUCTURAL DIMENSIONS AND
OPENINGS CONTROLLED BY ARCHITECTURAL, MECHANICAL, OR ELECTRICAL EQUIPMENT SHALL BE
VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION.
19. ALL IMPROVEMENTS TO CONFORM WITH FORSYTH COUNTY CONSTRUCTION STANDARDS AND
SPECIFICATIONS, LATEST EDITION.
20. UTILITY PERMIT REQUIRED. CONTACT UTILITY COORDINATOR MANAGER DAMON STANCIL AT 770-781-2165.
21. APPROVAL OF THESE PLANS DOES NOT CONSTITUTE APPROVAL BY FORSYTH COUNTY OF ANY LAND DISTURBING ACTIVITIES WITHIN WETLAND AREAS. IT IS THE RESPONSIBILITY OF THE PROPERTY OWNER TO CONTACT THE APPROPRIATE REGULATORY AGENCY FOR APPROVAL OF ANY WETLAND AREA DISTURBANCE.
22. MAXIMUM CUT SLOPES SHALL BE 2 HORIZONTAL TO 1 VERTICAL. CONTINUOUS FILL SLOPES TEN (10) FEET IN HEIGHT OR LESS MAY BE 2 HORIZONTAL TO 1 VERTICAL. ALL CONTINUOUS FILL SLOPES THAT EXCEED TEN (10) FEET IN HEIGHT MUST BE 3 HORIZONTAL TO 1 VERTICAL UNLESS: (A) A MECHANICALLY ENGINEERED STABILIZED SLOPE IS APPROVED BY THE FORSYTH COUNTY DIRECTOR OF ENGINEERING; OR (B) THE DESIGNED AND CONSTRUCTED SLOPES ARE CERTIFIED BY A REGISTERED ENGINEER EXPERIENCED IN
GEOTECHNICAL ENGINEERING AND LICENSED IN THE STATE OF GEORGIA.
23. APPROVAL OF THESE PLANS BY FORSYTH COUNTY IS SUBJECT TO AND CONTINGENT UPON THE APPLICANT OBTAINING ANY AND ALL NECESSARY APPROVALS FROM ANY AND ALL APPLICABLE AGENCIES INCLUDING BUT NOT LIMITED TO THE UNITED STATES ARMY CORPS OF ENGINEERS, THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY, AND THE USDA-NRCS, GEORGIA DEPARTMENT OF NATURAL RESOURCES, GEORGIA ENVIRONMENTAL PROTECTION DIVISION, AND THE GEORGIA SOIL AND WATER CONSERVATION COMMISSION.
24. ALL UNDISTURBED BUFFERS SHALL BE IDENTIFIED WITH ORANGE FOUR-FOOT TREE-SAVE FENCING PRIOR TO
ANY LAND DISTURBANCE (UDC SEC. 18-10.1).
25. PER THE APPLICABILITY STANDARDS, STORMWATER MANAGEMENT STANDARDS ARE NOT APPLICABLE TO THIS PROJECT. LESS THAN 5,000 SQUARE FEET OF IMPERVIOUS AREA ADDED. THIS PROJECT IS EXEMPT FROM THE STORMWATER MANAGEMENT STANDARDS PER SECTION 1.5.2 "LAND DISTURBING ACTIVITY THAT CONSISTS SOLELY OF CUTTING A TRENCH FOR UTILITY WORK AND RELATED PAVEMENT REPLACEMENT, WHILE MAINTAINING THE ORIGINAL GRADE."
SHEET
SEQ.
IS
SU
E
NO
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B
NO
FI
LE
N
AM
E
M
AY
AP
PR
OV
ED
CH
EC
KE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 4/29/2026 9:24 AM Plot By: CMiller Filename: C:\pw_working\carollo_200000\d0434328\203558_00G01.dwg
_0
0G
.d w g
La st
S av ed : 4
/2 9/
:2
AM
Sa ve d
By : C
M ill er Fi le na m e:
C :\p w _w or ki ng \c ar ol lo _2
0\ d0
\2
8_
G0 1.
dw g
AC
AD
R el
: 2 4.
3s (L
M S
Te ch
Ba r S ca le is o ne in ch o n or ig in al d ra w in g.
if no t o ne in ch o n th is sh ee t, ad ju st sc al e.
SITE DEVELOPMENT PLANS
.1
FO
RS
YT
H
CO
UN
TY
, G
EO
RG
IA
KE
NT
M
ER
E
LI
FT
S
TA
TI
ON
M
OD
IF
IC
AT
IO
NS
A
ND
F
OR
CE
M
AI
N
DE
SI
GN
Ca ro llo E ng in ee rs
, I nc
Ge or gi a Re gi st er ed
E ng in ee rin g
Fi rm
P
EF
-0
Ex pi re s 6
/3 0/
In te rs ta te N or th
P ar kw ay
Su ite
At la nt a, G
A
Ph on e
4)
-4
W eb w w w .fr ee se
.c om
0% F
IN
AL
D
ES
IG
N
GF
6/
/2
SI
TE
D
EV
EL
OP
M
EN
T
PL
AN
S
GF
5/
5/
GJEPCMM
A
G-1
AN
D
DR
AW
IN
G
IN
DE
X
GE
NE
RA
L N
OT
ES
GE
NE
RA
L
SHEET
NO.
DRAWING
NO. DESCRIPTION
(G) - GENERAL
1 G-0 COVER SHEET
2 G-1 GENERAL NOTES AND DRAWING INDEX
3 G-2 SURVEY NOTES, LEGEND, ABBREVIATIONS AND SYMBOLS
(C) - CIVIL
4 C-1 EXISTING LIFT STATION SITE PLAN AND PROPOSED VAULT SITE PLAN
5 C-2 FORCE MAIN PLAN AND PROFILE STA 0+00 TO 10+00
6 C-3 FORCE MAIN PLAN AND PROFILE STA 10+00 TO 20+00
7 C-4 FORCE MAIN AND GRAVITY PLAN AND PROFILE STA 20+00 TO END
8 C-5 CIVIL STANDARD DETAILS I
9 C-6 CIVIL STANDARD DETAILS II
10 C-7 CIVIL STANDARD DETAILS III
11 C-8 CIVIL STANDARD DETAILS IV
12 C-9 CIVIL STANDARD DETAILS V
(ES) - EROSION AND SEDIMENTATION
13 ES-1 EROSION CONTROL & UNIFORM CODE
14 ES-2 EROSION CONTROL NOTES
15 ES-3 EROSION CONTROL & MAPS
16 ES-4 EROSION CONTROL CHECKLIST
17 ES-5 FORCE MAIN STA 0+00 TO STA 20+00
18 ES-6 FORCE MAIN STA 20+00 TO END
19 ES-7 STANDARD DETAILS I
20 ES-8 STANDARD DETAILS II
(E) - ELECTRICAL
21 E-1 LEGEND I
22 E-2 LEGEND II
23 E-3 SITE PLAN
24 E-4 ONE-LINE DIAGRAM & INTERCONNECTION DIAGRAM
(PI) - PROCESS & INSTRUMENTATION
25 PI-1 LEGEND I
26 PI-2 LEGEND II
27 PI-3 EXISTING PROCESS DIAGRAM
28 PI-4 PROCESS DIAGRAM
DRAWING INDEX
D ig ita lly s ig ne d by G in y
Ja co b C on ta ct In fo : C ar ol lo E ng in ee rs
, I nc
D at e:
6.
.0
:0
8:
-0 4'
X X
REVISION DELTA
SCALE
FENCE
CENTER LINE
REMOVE AND/OR ABANDON
EXISTINGNEW
DETAIL REFERENCES HATCH PATTERNS
100'0 50' 200'
(EXIST)
KEY NOTE
EQUIPMENT/DEVICE
TAG AND NUMBER
PIPE TAG
BREAK LINE
TR
UE
N O
R
TH
PL
AN
T
NO
RT
H
30°
NORTH ARROW/PLANT NORTH
SYMBOLS
SURVEY NOTES
MATCH LINE
HIDDEN LINE
MATCH LINE SEE DWG ##X##
ELEVATION TOC XXXX.XX
EXISTING ELEVATION
PIPE BREAK
PLAN VIEW
PIPE BREAK
CROSS SECTION
CONSTRUCTION
FUTURE CONSTRUCTION
PIPE CONTINUATION
(SINGLE LINE)
BRACKET
EQUIPMENT
(E) = EXISTING EQUIPMENT
(F) = FUTURE EQUIPMENT
SIZE FLOW STREAM
(E) = EXISTING FLOW STREAM
(F) = FUTURE FLOW STREAM
LINE WORK
T.O.W. XXXX.X±
PIPE SIZE FLOW STREAM
XXX-XX-XXXX
X" XXX
TREAD PLATE
LANDSCAPING
GRATING
STEEL
ALUMINUM
BRONZE, BRASS,
OR COPPER
BRICK OR BLOCK
AGGREGATE BASE
COURSE (ABC)
BEDROCK
CAST IRON OR
FIBERGLASS
CLSM
CONCRETE
(ALL CLASSES)
DRAIN ROCK
STRUCTURAL FILL
OR BACKFILL
WOOD
SPAN
ASPHALT PAVING
GRAVEL
EXISTING/
UNDISTURBED SOIL
SAND OR GROUT
KEY TAG X
VIEW
VIEW
DRAWING CUT ORIGINATION
TYPICAL DETAIL #
FILE:
SCALE:
FILE:
SECTION CUT
TYPICAL DETAIL
REFERENCE
EXTERIOR ELEVATION
VIEWS
PHOTO LOCATION
AGRID BUBBLE
ARROW INDICATES
POINT OF VIEW
- = SHOWN ON SAME DRAWING
##X## = SEE INDICATED DRAWING
DRAWING REFERENCE ##X##
DISCIPLINE DESIGNATOR
SEE INDICATED
DRAWING
SHEETS IN
DETAIL
TYPICAL DETAIL NUMBER
TYPICAL DETAIL TITLE
AREA DESIGNATOR
(WHEN APPLICABLE)
DATE CREATED
(REVISED)
PLAN NOT REFERENCED
MODIFICATION NOTE
S = STANDARD
J = JOB SPECIFIC
R = REVISED
N = NOTE TO TYPICAL DETAIL USER
##X##
SHT # OF #MOD
LINE 2
LINE 1
LINE 3
VER DATE
TYP
C/1 ##X##
FILE
SCALE
C
A FILE
INDICATES LOCATED ON
TYPICAL DETAIL SHEETS
(TYP)
(TYP) - INDICATES THE
TYPICAL DETAIL IS USED IN
MULTIPLE LOCATIONS WITHIN
THE DRAWING
DESCRIPTION
SECTION/DETAIL
PLAN
VIEW DESCRIPTION, AS NECESSARY
SHEET NUMBER
DESCRIPTION
VIEW DESCRIPTION, AS NECESSARY
PLAN/VIEW TITLE
SECTION OR DETAIL
VIEW TITLE W/
REFERENCE
DETAIL OR
ENLARGED PLAN
CALL OUT
ALPHA = SECTION
NUMERIC = DETAIL
ALPHA = ENLARGED PLAN
NUMERIC = DETAIL
TYP
A ##X##
##X##
SEE INDICATED
DRAWING
SEE INDICATED
DRAWING
Know what's below.
Callbefore you dig.
(E)or (F)
(E)or (F)
GUARDRAIL
SHEET
SEQ.
IS
SU
E
NO
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B
NO
FI
LE
N
AM
E
M
AY
AP
PR
OV
ED
CH
EC
KE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 4/29/2026 9:30 AM Plot By: CMiller Filename: C:\pw_working\carollo_200000\d0434328\203558_00G02.dwg
_0
0G
.d w g
La st
S av ed : 4
/2 9/
:3 d
By : C
M ill er Fi le na m e:
C :\p w _w or ki ng \c ar ol lo _2
0\ d0
\2
8_
G0 2.
dw g
AC
AD
R el
: 2 4.
3s (L
M S
Te ch
Ba r S ca le is o ne in ch o n or ig in al d ra w in g.
if no t o ne in ch o n th is sh ee t, ad ju st sc al e.
SITE DEVELOPMENT PLANS
.1
FO
RS
YT
H
CO
UN
TY
, G
EO
RG
IA
KE
NT
M
ER
E
LI
FT
S
TA
TI
ON
M
OD
IF
IC
AT
IO
NS
A
ND
F
OR
CE
M
AI
N
DE
SI
GN
Ca ro llo E ng in ee rs
, I nc
Ge or gi a Re gi st er ed
E ng in ee rin g
Fi rm
P
EF
-0
Ex pi re s 6
/3 0/
In te rs ta te N or th
P ar kw ay
Su ite
At la nt a, G
A
Ph on e
4)
-4
W eb w w w .fr ee se
.c om
0% F
IN
AL
D
ES
IG
N
GF
6/
/2
SI
TE
D
EV
EL
OP
M
EN
T
PL
AN
S
GF
5/
5/
GJEPCMM
A
G-2
AB
BR
EV
IA
TI
ON
S
AN
D
SY
M
BO
LS
SU
RV
EY
N
OT
ES
, L
EG
EN
D, GE
NE
RA
L
TREE LEGEND
SYMBOL CODE COMMON NAME
BE BEECH
M MAPLE
K OAK
P PINE
PO POPLAR
EXAMPLE
16K = 16 INCH OAK TREE
TRUNK DIAMETER MEASURED AT
BREAST HEIGHT. TREE SYMBOL
SIZE VARIES BASED ON TREE
DIAMETER.
IRON PIN FOUND (DESCRIPTION)
RIGHT OF WAY MONUMENT
BENCHMARK
SANITARY SEWER MANHOLE
CLEAN OUT
STORM DRAIN MANHOLE
GAS VALVE
WATER METER
WATER VALVE
FIRE HYDRANT
IRRIGATION CONTROL VALVE
UTILITY POLE
LIGHT POLE
TRANSFORMER
ELECTRIC METER
TELEPHONE PEDESTAL
COMMUNICATION HANDHOLE
SIGN (SINGLE POST)
MAILBOX
H
B.O.S. BOTTOM OF STRUCTURE
BW BOTTOM OF WALL
BLDG BUILDING
-C- UNDERGROUND COMMUNICATION LINE
CLF CHAIN LINK FENCE
CMP CORRUGATED METAL PIPE
CONC. CONCRETE
CTP CRIMP TOP PIPE
DB DEED BOOK
DIP DUCTILE IRON PIPE
DIST. DISTURBED
DWCB DOUBLE WING CATCH BASIN
E.N.F. END NOT FOUND
E.N.L. END NOT LOCATED
EP EDGE OF PAVEMENT
EX EXISTING
FES FLARED END SECTION
-FO- FIBER OPTIC
-G- UNDERGROUND GAS LINE
HW HEADWALL
I.I. INVERT IN
I.O. INVERT OUT
I.E. INVERT ELEVATION
JB JUNCTION BOX
LF LINEAR FEET
L.L. LAND LOT
N/F NOW OR FORMERLY
N.T.S. NOT TO SCALE
OCS OUTLET CONTROL STRUCTURE
-OE- OVERHEAD ELECTRIC
PB PLAT BOOK
PG PAGE
P.I.N. PARCEL IDENTIFICATION NUMBER
P/L PROPERTY LINE
PV PLUG VALVE
PVC POLYVINYL CHLORIDE PIPE
RB REBAR
RBC REBAR WITH CAP
RCP REINFORCED CONCRETE PIPE
R/W RIGHT OF WAY
SD STORM DRAIN
-SS- SANITARY SEWER
SSMH SANITARY SEWER MANHOLE
SWCB SINGLE WING CATCH BASIN
-TL- TREE LINE
TW TOP OF WALL
TYP. TYPICAL
-W- UNDERGROUND WATER LINE
-UE- UNDERGROUND ELECTRIC LINE
UNKN UNKNOWN
-UT- UNDERGROUND TELEPHONE LINE
1. HORIZONTAL COORDINATES SHOWN ARE IN U.S. SURVEY FEET, AND ARE BASED UPON THE U.S. STATE PLANE COORDINATE SYSTEM, NORTH AMERICAN DATUM OF 1983, GEORGIA STATE PLANE, WEST ZONE.
2. VERTICAL ELEVATIONS SHOWN ARE IN U.S. SURVEY FEET, AND ARE BASED UPON THE NORTH AMERICAN
VERTICAL DATUM OF 1988.
3. NO EXISTING UNDERGROUND UTILITIES HAVE BEEN LOCATED AND/OR SHOWN ON THIS SURVEY. ONLY
VISIBLE AND APPARENT ABOVE GROUND UTILITY APPURTENANCES ARE SHOWN.
4. THIS SURVEY DOES NOT PROVIDE A DELINEATION OR OPINION CONCERNING THE LOCATION OR
EXISTENCE OF WETLANDS, FAULT LINES, TOXIC OR HAZARDOUS WASTE AREAS, SUBSIDENCE,
SUBSURFACE AND ENVIRONMENTAL CONDITIONS OR GEOLOGICAL ISSUES. NO STATEMENT IS MADE CONCERNING THE SUITABILITY, OF THE SUBJECT TRACT FOR ANY INTENDED USE, PURPOSE OR
DEVELOPMENT.
5. GRAPHICAL DEPICTION OF TOPOGRAPHIC INFORMATION SHOWN ON THIS SURVEY WAS PRODUCED FROM
SURVEY PROVIDED BY LAND ENGINEERING, INC., COMPLETED ON AUGUST 1, 2024.
SURVEY LEGEND ABBREVIATIONS
D ig ita lly s ig ne d by G in y
Ja co b C on ta ct In fo : C ar ol lo E ng in ee rs
, I nc
D at e:
6.
.0
:0
2:
-0 4'
G G
G G
G
UE
UE
UE
UE
UE
UE
UE
8' C
LF
CONC.
GU
Y
W
IR
E
W
AT
ER
O
UT
LE
T
DO
UB
LE
S
W
IN
G
CL
F
GA
TE
GR
AV
EL
X
X
X
X
X
X
X
1109.01
UPW OHE1 -X
63581102.16GV UGL1
1102.44EM UEL1
1102.60
LPM UEL
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
OE
OE
OE
OE
OE
OE
OE
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
W
SS
M
H
TO
P:
.9
I.O
.(A ):1
1.
I.I
.(B ):1
1.
(A
(B
8" D
IP
(A
(B
(C
SS
M
H
TO
P:
.1
I.O
.(A ):1
4.
I.I
.(B ):1
5.
I.I
.(C ):1
4.
SE
W
ER
V
AL
VE
W
AT
ER
CA
BI
NE
T
BLDG
UE
UE
' P
UM
P
ST
AT
IO
N
EA
SE
M
EN
T
PE
R
PB
7, P G
GRAVEL
AS
PH
AL
T
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G G
G G
G
UE
UE
UE
UE
UE
UE
UE
8' C
LF
CONC.
GU
Y
W
IR
E
GR
AV
EL
X
X
X
X
1109.01
UPW OHE1 -X
63581102.16GV UGL1
63931102.44EM UEL1
1102.60
LPM UEL
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
OE
OE
OE
OE
OE
OE
OE
FM
FM
FM
FM
FM
FM
FM
FM
FM
W
SS
M
H
TO
P:
.9
I.O
.(A ):1
1.
I.I
.(B ):1
1.
(A
(B
8" D
IP
(A
(B
(C
SS
M
H
TO
P:
.1
I.O
.(A ):1
4.
I.I
.(B ):1
5.
I.I
.(C ):1
4.
W
AT
ER
CA
BI
NE
T
BLDG
UE
UE
' P
UM
P
ST
AT
IO
N
EA
SE
M
EN
T
PE
R
PB
7, P G
GRAVEL
AS
PH
AL
T
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
0+00
FLOW METER VAULT 2
6" 90° BEND (VERT)
EMERGENCY STUBOUT
WITH 6" PV
FLOW METER
VAULT 1
6"x6" TEE
STA 0+27.47
N 1515747.60 E 2289964.14
X
X
X
X
X X X X X
X X
X X
X X
X X
X X
X X
X X
XX
X
6" 45° BEND
STA 0+16.22
N 1515758.85 E 2289963.83
8" PV
N 1515770.08 E 2289954.84
N 1515717.36 E 2289935.32
N 1515760.05 E 2289910.64
N 1515773.64 E 2289968.12
N 1515737.51 E 2289970.18
6" DIP FM
(CL 350)
8" DIP FM
(CL 350)
8"x6" WYE
STA 0+00.00
N 1515770.00 E 2289952.06
N 1515737.66 E 2289960.75
N 1515745.19 E 2289967.88
N 1515774.03 E 2289965.38
N 1515766.50 E 2289958.25
6" 11.25° BEND (VERT)
STA 0+11.11
N 1515762.36 E 2289960.12
6" 11.25° BEND (VERT)
STA 0+03.00
N 1515767.94 E 2289954.23
6" 45° BEND
STA 0+44.73
N 1515730.35 E 2289964.61
6" DIP FM
(CL 350)
.3
FILE:
PLAN
EXISTING LIFT STATION SITE
GENERAL NOTES:
1. ALL EXISTING UTILITIES ARE SHOWN IN APPROXIMATE
LOCATIONS. THE INFORMATION OBTAINED FROM
AVAILABLE RECORD DRAWINGS, SURVEY INFORMATION,
AND GIS DATA. CONTRACTOR SHALL FIELD VERIFY THE
LOCATION, DEPTH, AND CONDITION OF ALL EXISTING
UTILITIES PRIOR TO BEGINNING WORK. ANY
DISCREPANCIES BETWEEN THE PLAN AND ACTUAL SITE
CONDITIONS MUST BE REPORTED TO THE EOR
IMMEDIATELY.
2. THE CONTRACTOR MUST TAKE ALL NECESSARY
PRECAUTIONS TO PROTECT EXISTING UTILITIES DURING
CONSTRUCTION. ANY DAMAGE TO EXISTING UTILITIES
CAUSED BY THE CONTRACTOR’S OPERATIONS MUST BE
REPAIRED AT THE CONTRACTOR’S EXPENSE.
3. SEE SHEET C-2 FOR FORCE MAIN PLAN AND PROFILE.
4. ALL PIPE JOINTS SHALL BE RESTRAINED USING
MECHANICAL JOINTS AND THRUST BLOCKS PER DETAILS
ON SHEETS C-8 AND C-9.
5. CONTRACTOR TO MAINTAIN DRIVABLE ACCESS ALONG
EXISTING ROADS AT ALL TIMES.
6. ALL MEASUREMENTS OF EXISTING TOPOGRAPHY,
STRUCTURES, COORDINATE POINTS, AND UTILITIES ARE
SUBJECT TO VERIFICATION IN THE FIELD BY THE
CONTRACTOR. THE CONTRACTOR SHALL NOTIFY THE
ENGINEER-OF-RECORD (EOR) OF ANY DISCREPANCIES
ON THE DRAWINGS PRIOR TO THE FABRICATION OR
CONSTRUCTION. THE CONTRACTOR WILL BE
RESPONSIBLE FOR ANY ERRORS WHICH MAY HAVE
BEEN AVOIDED BY FIELD VERIFICATION.
7. DO NOT INTERRUPT EXISTING UTILITIES SERVING
OCCUPIED OR USED FACILITIES EXCEPT WHEN
AUTHORIZED BY THE EOR. PROVIDE TEMPORARY
SERVICES DURING INTERRUPTIONS TO EXISTING
UTILITIES AS REQUIRED.
8. CONTRACTOR TO COORDINATE WITH THE ELECTRICAL
UTILITY OWNER. TEMPORARILY BRACE POWER LINE
POLES FOR CONSTRUCTION PER UTILITY
REQUIREMENTS.
9. LIMITED EXISTING PIPING IS SHOWN, CONTRACTOR
SHALL FIELD VERIFY LOCATION OF EXISTING UTILITIES
PRIOR TO BEGINNING WORK.
# KEY NOTES:
1. EXISTING CHAIN LINK FENCE AND SWING GATE TO BE
REMOVED. NO DEMO TO CONCRETE PAD.
CONTRACTOR TO REPAIR ANY DAMAGE TO
CONCRETE ON PAD FROM FENCE POST REMOVAL.
2. EXISTING 8" DIP FM, VALVES AND BYPASS TO BE
REMOVED.
3. THE CONTRACTOR IS REQUIRED TO VERIFY THE
EXACT LOCATION OF THE EXISTING 8" DIP FM TO
CONNECT WITH 8" DIP FM. THE CURRENT LOCATION IS
DERIVED FROM RECORD DRAWINGS, SURVEY
INFORMATION, AND GIS DATA. ANY DISCREPANCIES
MUST BE REPORTED TO THE ENGINEER-OF-RECORD
(EOR).
4. REMOVED EXISTING ASPHALT DRIVEWAY AND
GRAVEL.
5. CONNECT TO THE EXISTING FORCE MAIN AT THE
VERTICAL 45° BEND.
6. SEE SHEET C-6 FOR FLOW METER VAULT DETAIL.
7. CONSTRUCT 5'x24' CONCRETE PAD FOR FUTURE
CHEMICAL STORAGE TANK.
8. FUTURE CHEMICAL STORAGE TANK (10-FT DIA).
9. INSTALL PIPE UTILITY MARKERS PER DETAIL ON
SHEET C-8.
SHEET
SEQ.
IS
SU
E
NO
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B
NO
FI
LE
N
AM
E
JU
NE
AP
PR
OV
ED
CH
EC
KE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 4/29/2026 8:39 AM Plot By: CMiller Filename: C:\pw_working\carollo_200000\d0434344\203558_00C01.dwg
_0
0C
.d w g
La st
S av ed : 7
/7 /2
1:
P M d
By : C
M ill er Fi le na m e:
C :\p w _w or ki ng \c ar ol lo _2
0\ d0
\2
8_
C0 1.
dw g
AC
AD
R el
: 2 4.
3s (L
M S
Te ch
Ba r S ca le is o ne in ch o n or ig in al d ra w in g.
if no t o ne in ch o n th is sh ee t, ad ju st sc al e.
SITE DEVELOPMENT PLANS
.1
FO
RS
YT
H
CO
UN
TY
, G
EO
RG
IA
KE
NT
M
ER
E
LI
FT
S
TA
TI
ON
M
OD
IF
IC
AT
IO
NS
A
ND
F
OR
CE
M
AI
N
DE
SI
GN
Ca ro llo E ng in ee rs
, I nc
Ge or gi a Re gi st er ed
E ng in ee rin g
Fi rm
P
EF
-0
Ex pi re s 6
/3 0/
In te rs ta te N or th
P ar kw ay
Su ite
At la nt a, G
A
Ph on e
4)
-4
W eb w w w .fr ee se
.c om
0% F
IN
AL
D
ES
IG
N
GF
6/
/2
SI
TE
D
EV
EL
OP
M
EN
T
PL
AN
S
GF
5/
1/
20'10'0 5'
SCALE: 1" = 10'
usanorth811.org
FILE:
PLAN
PROPOSED VAULT
EX 8" DIP FM EX 8" DIP SS
EX LIFT STATION
BUILDING
EX LIFT STATION
BUILDING
EX 30' EASEMENT
EX
0' E
AS
EM
EN
T
EX 20' EASEM
EN
T
EX 30' EASEMENT
EX
0' E
AS
EM
EN
T
EX 20' EASEM
EN
T
GJEPCMM
A
C-1
AN
D
PR
OP
OS
ED
V
AU
LT
S
IT
E
PL
AN
EX
IS
TI
NG
LI
FT
S
TA
TI
ON
S
IT
E
PL
AN
CI
VI
L
14' WIDE
SWING GATE
CHAIN-LINK
FENCE (TYP)
EX CHAIN-LINK
FENCE
TYP
CF160
PROPOSED ±20' OF 8" DIP
(CERAMIC EPOXY) FM
(REPLACE EX 8" DIP FROM
THE HORIZONTAL BEND
AT LIFT STATION TO THE
45° VERTICAL BEND)
PERMANENT EASEMENT
(SEE SHEET C-2)
15'
GUARD
POST
(TYP)
EX 8" DIP FM EX 8" DIP SS
D ig ita lly s ig ne d by G in y
Ja co b C on ta ct In fo : C ar ol lo E ng in ee rs
, I nc
D at e:
6.
.0
:0
6:
-0 4'
-0+50 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00
EX
" D
IP
S S
IN
V
.7
EX
E
LE
C
ST
A.
+9
4.
C L
EL
=1
3.
(2
° M
AX
D
EF
LE
C
TI
O
N
EXISTING GROUND
ST
A
0+
.6
FL
O
W M
ET
ER
V
AU
LT
R
IM
4.
ST
A=
0+
8" x6
" W
YE
C L
EL
=1
6.
ST
A=
0+
.2
6"
5° B
EN
D
C L
EL
=1
8.
ST
A=
0+
.4
6" x6
" T
EE
C L
EL
=1
8.
6" P
V
ST
A 0+
.6
ST
A.
+4
6.
C L
EL
=1
8.
(4
° M
AX
D
EF
LE
C
TI
O
N
ST
A=
0+
.7
6"
5° B
EN
D
C L
EL
=1
8.
ST
A=
0+
.9
6"
5° B
EN
D
C L
EL
=1
9.
ST
A.
+2 3.
C
L
EL
=1
0.
(4 ° M
AX
D
EF
LE
C
TI
O N
ST
A.
+0
5.
C L
EL
=1
3.
(2
° M
AX
D
EF
LE
C
TI
O
N
ST
A=
3+
.5
6"
5° B
EN
D
C L
EL
=1
3.
ST
A=
3+
.6
6"
5° B
EN
D
(V
ER
T) C
L
EL
=1
3.
ST
A=
3+
.8
6"
1.
° B
EN
D C
L
EL
=1
9.
ST
A=
3+
.3
6"
5° B
EN
D
C L
EL
=1
8.
ST
A=
3+
.3
6"
1.
° B
EN
D (V
ER
T)
C L
EL
=1
3.
ST
A=
4+
.3
6"
1.
° B
EN
D (V
ER
T)
C L
EL
=1
3.
ST
A=
4+
.8
6"
1.
° B
EN
D (V
ER
T)
C L
EL
=1
7.
ST
A= 4+
.1
6"
2.
° B
EN
D
C L
EL
=1
7.
ST
A= 4+
.9
6"
5°
B
EN
D C
L
EL
=1
7.
ST
A=
5+
.9
6"
5° B
EN
D
C L
EL
=1
7.
ST
A=
5+
.2
6"
5° B
EN
D
C L
EL
=1
7.
ST
A=
6+
.5
6"
1.
° B
EN
D C
L
EL
=1
0.
ST
A=
6+
.2
6"
2.
° B
EN
D (V
ER
T)
C L
EL
=1
0.
ST
A=
7+
.8
6"
2.
° B
EN
D (V
ER
T)
C L
EL
=1
4.
ST
A.
+6
0.
C L
EL
=1
7.
(4
° M
AX
D
EF
LE
C
TI
O
N
ST
A.
+1
0.
C L
EL
=1
5.
(4
° M
AX
D
EF
LE
C
TI
O
N
0.74%
1.75% 1.74%
0.00%
3.14% 0.25%
2.24%
ST
A.
+5
9.
C O
N C
R
ET
E
AN
C H
O R
ST
A.
+7
9.
C O
N C
R
ET
E
AN
C H
O R
ST
A.
+9
9.
C O
N C
R
ET
E
AN
C H
O R
EX
" D
IP
S S
IN
V
.4
EX
" D
IP
S S
IN
V
.5
.6
4%
ST
A
3+
C
AR
V
R
IM
9.
22.08%
6" DIP FM
(CL 350) (TYP)
ST
A=
0+
6"
1.
° B
EN
D (V
ER
T)
C L
EL
=1
6.
ST
A= 0+
.1
6"
1.
° B
EN
D
(V
ER
T) C
L
EL
=1
8.
2.79%
G G G
UE
8' C
LF
CONC.
GU
Y
W
IR
E
GR
AV
EL GU
Y
W
IR
E
GU
Y
W
IR
E
HW
I.E .:1
6.
" R
CP
" R
CP
JB
TO
P:
.5
I.O
.(A ):1
7.
I.I
.(B ):1
3.
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOODFLOODFLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOODFLOODFLOODFLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOODFLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOODFLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FL
OO
D
FLOODFLOODFLOODFLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD FLOOD
FLOOD
FLOOD
FLOOD
FLO
OD
FLO
OD
FLO
OD
FLO
OD
FL
OO
D
FL
OO
D
FL
OO
D
FL
OO
D
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD
FLOOD FLOOD FLOOD
FLOOD
FLOOD
FLO
OD
FLO
OD
FLO
OD
FLO
OD
FLO
OD
FLO
OD
FLO
OD
FLOOD
FLOOD
FLO
OD
FLO
OD
FLO
OD
FLO
OD
FLO
OD
FL
OO
D
FL
OO
D
FLOOD
FLOOD
FLOOD
FLOOD FLOOD
FLOOD
FLOOD
FLOOD FLOOD FLOOD
FLOOD
FLOOD
FLOOD FLOOD FLOOD
FLO
OD
FLO
OD
FLOOD
FLOOD FLOOD FLOOD FLOOD
FLOOD
FLOOD
FLOOD
FLO
OD
FLO
OD
FL
OO
D
FLO
OD
FLO
OD
FLOOD
FL
OO
D
FL
OO
D
FL
OO
D
FL
OO
D
ZO
NE
A F
LO
OD
PL
AI
N
PE
R
FE
M A
M
AP
C0
7F
ZO
NE
A
FL
OO
DP
LA
IN
PE
R
FE
M
A M
AP
7C
F
BE
NC
HM
AR
K 5/
8" R
BC
EL
EV
. 1
7.
TOP O
F B
ANK
TO
P
OF
B
AN
K
1/ 2"
R B
1/ 2"
R B
2K
24PO
23K
19K
30K
18K
20K 18K
18K
20K
24K
35K
35BE
.10
HW
1122.52
MHSD
1120.34
UPW OHE1 -X
27PO
26PO
27X28PO
25P 1101.69
UPW UTL1 B
27P
26P
1111.98
UPW OHE1 -X
1109.01
UPW OHE1 -X
63581102.16GV UGL1
63931102.44EM UEL1
1102.60
LPM UEL
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS
SS
SS
SS
SS->
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
FM
FM
FM
SS
M
H
TO
P:
.9
I.O
.(A ):1
1.
I.I
.(B ):1
1.
(A
)(B
8" D
IP
8" DIP
E.
N.
L. (A
(B
(C
SS
M
H
TO
P:
.1
I.O
.(A ):1
4.
I.I
.(B ):1
5.
I.I
.(C ):1
4.
8" D
IP
E.
N.
L.
8" DIP
SS
M
H
TO
P:
.8
I.O
.(A ):1
6.
I.I
.(B ):1
6.
(A
(B
8" DIP
8" D
IP
(A
(B
(C
SS
M
H
TO
P:
.7
I.O
.(A ):1
7.
I.I
.(B ):1
7.
I.I
.(C ):1
7.
E.
N.
L.
8"
D
IP
8" DIP
(A ) (B
(C
SS
M
H
TO
P:
.5
I.O
.(A ):1
2.
I.I
.(B ):1
2.
I.I
.(C ):1
2.
E.
N.
L.
8" D
IP
8" DIP
8" D
IP
8" DIP
8" PVC
8" PVC
(A
(B
(C
E.
N.
L.
SS
M
H
TO
P:
.4
I.O
.(A ):1
2.
I.I
.(B ):1
3.
I.I
.(C ):1
4.
SS
M
H
TO
P:
.4
I.O
.(A ):1
3.
I.I
.(B ):1
5.
(A
) (B
(A ) (B
SS
M
H
TO
P:
.3
I.O
.(A ):1
0.
I.I
.(B ):1
0.
E.
N.
L.
RI
P
RA
P
POINT OF
WRESTED
VEGETATION
BI
G
CR
EE
K
TR
IB
UT
AR
Y
K.
C/ L
BI
G
CR
EE
K
TR
IB
UT
AR
Y
K.
C/ L
W
AT
ER
CA
BI
NE
T
TR
EE
LI
NE
TR
EE
LI
NE
TR
EE
LI
NE
TR
EE
LI
NE
TR
EE
LI
NE
TR
EE
LI
NE
TR
EE
LI
NE
TR
EE
LI
NE
CONC.
BLDG
GU
Y
W
IR
E
APPROXIMATE L.L.L. PER PB 18, PG 41
APPROXIMATE L.L.L. PER PB 101, PG 188
N/F
CAROLYN L. PELTIER
AND
GORDON J. PELTIER
P.I.N.:106 053
DB 5871, PG 265
LOT 12
PB 18, PG 41
N/F
BULLS EYE MARKSMAN, LLC
P.I.N.:106 402
DB 3630, PG 255
PB 69, PG 212
N/F
KENTMERE PROPERTY
OWNERS ASSOCIATION, INC.
P.I.N.:083 062
DB 2053, PG 535
N/F
CAROLYN L. PELTIER
AND
GORDON J. PELTIER
P.I.N.:106 798
LOT 13
PB 18, PG 41
N/F
KENTMERE PROPERTY
OWNERS ASSOCIATION, INC.
P.I.N.:083 062
DB 2053, PG 535
1141.49
IPF-4RB
1109.41
IPF-4RB
' S
SE
P
ER
PB
PG
APPARENT 20' SSE
AP
PR
OX
IM
AT
E
W
AT
ER
L
OC
AT
IO
N
PE
R
PB
PG
P/L
P/L
P/L
P/ L
P/L
20' SSE PER PB 67, PG 1
20' SSE PER PB 4112, PG 302
20' SSE PER PB 4112, PG 302
EX
IS
TI
NG
0'
S
SE
PE
R
PB
2, P G
' S
SE
P
ER
P
B
, P G
20' SSE PER PB 67, PG 1
20' SSE PER PB 67, PG 120' SSE PER PB 67, PG 1
' A
CC
ES
S
EA
SE
M
EN
T
PE
R
PB
7, P
G
E.
N.
L.
' P
UM
P
ST
AT
IO
N
EA
SE
M
EN
T
PE
R
PB
7, P G
1 GRAVEL
' D
.E . P
ER
P
B
, P G
' D
.E . P
ER
P
B
, P G
' D
.E . P
ER
P
B
, P G
1AS
PH
AL
T
W
W
W
W
W
W
W
WWWWWWWWW
W
W
W
W
W
W
30'
20'
6" 22.50° BEND
STA 4+84.15
N 1515352.38 E 2289914.63
0+00
1+00 2+00
3+00
4+00
5+00 6+00
7+00
8+00
9+00
10+00
X X
X X
X
6" 11.25° BEND
STA 10+24.81
N 1514874.37 E 2290148.30
6" 45° BEND
STA 4+88.92
N 1515347.68 E 2289913.87
6" 11.25° BEND (VERT)
STA 4+56.39
N 1515376.63 E 2289928.16
6" 11.25° BEND (VERT)
STA 4+73.83
N 1515361.39 E 2289919.66
6" 22.50° BEND (VERT)
STA 6+55.25
N 1515204.86 E 2289983.32
6" 22.50° BEND (VERT)
STA 7+11.84
N 1515152.77 E 2290005.44
8"x6" WYE
STA 0+00.00
N 1515770.00 E 2289952.06
6"x6" TEE
STA 0+27.47
N 1515747.60 E 2289964.14
6" 45° BEND
STA 0+16.22
N 1515758.85 E 2289963.83
6" 45° BEND
STA 0+87.97
N 1515700.62 E 2289996.00
6" 45° BEND
STA 3+09.75
N 1515479.86 E 2290017.22
6" 45° BEND
STA 3+20.52
N 1515471.55 E 2290010.37
6" 11.25° BEND
STA 3+46.88
N 1515469.03 E 2289984.13
6" 45° BEND
STA 5+66.21
N 1515278.71 E 2289933.67
6" 11.25° BEND
STA 6+52.50
N 1515207.39 E 2289982.24
6" 45° BEND
STA 0+44.73
N 1515730.35 E 2289964.61
6" 45° BEND (VERT)
STA 3+31.61
N 1515470.49 E 2289999.33
6" 45° BEND
STA 3+52.38
N 1515467.44 E 2289978.87
6" 11.25° BEND (VERT)
STA 3+74.31
N 1515448.29 E 2289968.17
6" FLOW METER
STA 0+33.21
N 1515741.86 E 2289964.30
CARV
STA 3+00.00
N 1515489.56 E 2290016.29
6" 45° BEND
STA 5+34.99
N 1515309.38 E 2289939.48
6" 11.25° BEND (VERT)
STA 0+11.11
N 1515762.36 E 2289960.12
6" 11.25° BEND (VERT)
STA 0+03.00
N 1515767.94 E 2289954.23
6" DIP FM (CL 350)
6" DIP FM (CL 350)
STA 7+42.98
Δ 2.23° LT
N 1515124.43 E 2290018.32
STA 7+22.99
Δ 2.23° LT
N 1515142.51 E 2290009.80
SHEET
SEQ.
IS
SU
E
NO
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B
NO
FI
LE
N
AM
E
M
AY
AP
PR
OV
ED
CH
EC
KE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 4/30/2026 7:28 AM Plot By: CMiller Filename: C:\pw_working\carollo_200000\d0434344\203558_00C02.dwg
_0
0C
.d w g
La st
S av ed : 4
/2 9/
0:
A d By
: C M ill er
Fi le na m e:
C
:\p w
_w or ki ng
\c ar ol lo
_2
0\ d0
\2
8_
C0
2.
dw g
AC
AD
R el : 2
4.
3s
(L M
S Te ch
Ba r S ca le is o ne in ch o n or ig in al d ra w in g.
if no t o ne in ch o n th is sh ee t, ad ju st sc al e.
SITE DEVELOPMENT PLANS
.1
FO
RS
YT
H
CO
UN
TY
, G
EO
RG
IA
KE
NT
M
ER
E
LI
FT
S
TA
TI
ON
M
OD
IF
IC
AT
IO
NS
A
ND
F
OR
CE
M
AI
N
DE
SI
GN
Ca ro llo E ng in ee rs
, I nc
Ge or gi a Re gi st er ed
E ng in ee rin g
Fi rm
P
EF
-0
Ex pi re s 6
/3 0/
In te rs ta te N or th
P ar kw ay
Su ite
At la nt a, G
A
Ph on e
4)
-4
W eb w w w .fr ee se
.c om
0% F
IN
AL
D
ES
IG
N
GF
6/
/2
SI
TE
D
EV
EL
OP
M
EN
T
PL
AN
S
GF
5/
5/
80'40'0 20'
SCALE: 1" = 40' (HORIZ)
20'10'0 5'
SCALE: 1" = 10' (VERT)
usanorth811.org
GJEPCMM
R
C-2
ST
A
0+
T O
+0
FO
RC
E
M
AI
N
PL
AN
A
ND
P
RO
FI
LE
CI
VI
L
18"
(MIN)
FILE:
PLAN
PROFILE
AT
C H
L
IN
E
ST
A
+0
FO
R
C O
N
TI
N U
AT
IO
N S
EE
C
-3
STREAM CROSSING
STREAM CROSSING
4'
(MIN)
3'
(MIN)
SEE SHEET C-1
FOR MORE DETAIL
35 LF OF 12" STEEL
CASING PIPE
(0.375" MIN WT)
40 LF OF 12" STEEL
CASING PIPE
(0.375" MIN WT)
10'
(MIN)
10'
(MIN)
CONCRETE
ANCHOR
(TYP 3)
C-5
42' PERMANENT
EASEMENT
12' PERMANENT
EASEMENT
10' PERMANENT
EASEMENT
# KEY NOTES:
1. STREAM CROSSING TO BE OPEN CUT PER
DETAIL 16/C-7.
2. CONTRACTOR TO RESTORE RIPRAP TO
EXISTING SIZE OF MATERIAL AND DEPTH.
3. ALL PIPE JOINTS SHALL BE RESTRAINED USING
MECHANICAL JOINTS AND THRUST BLOCKS
PER DETAILS ON SHEETS C-8 AND C-9.
4. INSTALL PIPE UTILITY MARKERS PER DETAIL
ON SHEET C-8.
5. CONTRACTOR SHALL FIELD VERIFY THE
LOCATION, DEPTH, AND CONDITION OF ALL
EXISTING UTILITIES PRIOR TO BEGINNING
WORK. ANY DISCREPANCIES BETWEEN THE
PLAN AND ACTUAL SITE CONDITIONS MUST BE
REPORTED TO THE EOR IMMEDIATELY.
6. STREAM BUFFER VARIANCE REQUIRED PER
GEORGIA ENVIRONMENTAL PROTECTION
DIVISION FOR ENCROACHMENT OF 25-FOOT
STREAM BUFFER.
7. UTILITY PERMIT REQUIRED. CONTACT UTILITY
COORDINATOR MANAGER DAMON STANCIL AT
(770) 781-2165.
18"
(MIN)
18"
(MIN)
4 (TYP)
C-7
MANHOLE VENT
ASSEMBLY
W/ODOR CONTROL
C-8
POINT OF WRESTED
VEGETATION BOUNDARY
25' STREAM BUFFER
ENCROACHMENT EXTENTS
25' STREAM BUFFER
ENCROACHMENT EXTENTS
' S
TREAM BUFFER
POINT OF WRESTED
VEGETATION BOUNDARY
D ig ita lly s ig ne d by G in y
Ja co b C on ta ct In fo : C ar ol lo E ng in ee rs
, I nc
D at e:
6.
.0
:0
3:
-0 4'
10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00
EXISTING GROUND
ST
A=
+2
0.
6"
5° B
EN
D
C L
EL
=1
4.
EX
4" S
D C
M P
IN
V
.3
EX
8" S
D R
C P
IN
V
.6
EX
" D
IP
W
IN
V U
N
KN
EX
G
AS
IN
V U
N
KN
EX
4" S
D
IN
V
.5
EX
F
O
IN
V U
N
KN
EX
T
EL
IN
V U
N
KN
EX
G
AS
IN
V U
N
KN
EX
" D
IP
W
IN
V U
N
KN
EX
W
S
ER
VI
C
E
IN
V U
N
KN
EX
T
EL
IN
V U
N
KN
EX
G
AS
IN
V U
N
KN
EX
W
S
ER
VI
C
E
IN
V U
N
KN
EX
8" S
D R
C P
IN
V
.1
EX
W
S
ER
VI
C
E
IN
V U
N
KN
EX
G
AS
IN
V U
N
KN
EX
W
S
ER
VI
C
E
IN
V U
N
KN
EX
T
EL
IN
V U
N
KN
EX
G
AS
IN
V U
N
KN
EX
8" S
D R
C P
IN
V
.4
6.24% 2.74% 0.13%
ST
A=
+8
6.
6"
2.
° B
EN
D C
L
EL
=1
8.
ST
A=
+5
9.
6"
1.
° B
EN
D C
L
EL
=1
8.
ST
A=
+4
4.
6"
1.
° B
EN
D C
L
EL
=1
1.
ST
A=
+9
4.
6"
5° B
EN
D
C L
EL
=1
3.
ST
A=
+0
9.
6"
5° B
EN
D
C L
EL
=1
4.
ST
A.
7+
.3
C L
EL
=1
4.
(4
° M
AX
D
EF
LE
C
TI
O
N
ST
A.
8+
.2
C
L
EL
=1
8.
(4 ° M
AX
D
EF
LE
C
TI
O N
ST
A.
9+
.0
C
L
EL
=1
3.
(4 ° M
AX
D
EF
LE
C
TI
O N
ST
A=
+4
4.
6"
2.
° B
EN
D C
L
EL
=1
5.
EX
E
LE
C
IN
V
U N
KN
EX
" P
VC
S S
IN
V
.0
ST
A.
4+
.4
C
L
EL
=1
7.
(4 ° M
AX
D
EF
LE
C
TI
O N
ST
A.
5+
.0
C
L
EL
=1
8.
(4 ° M
AX
D
EF
LE
C
TI
O N
8.47% 3.06%
0.20%
EX
" D
IP
S S
IN
V
.3
EX
" D
IP
S S
IN
V
.2
ST
A=
+2
4.
6"
1.
° B
EN
D C
L
EL
=1
8.
ST
A.
4+
.6
C
L
EL
=1
7.
(4 ° M
AX
D
EF
LE
C
TI
O N
ST
A=
+9
4.
6"
1.
° B
EN
D C
L
EL
=1
9.
ST
A=
+1
6.
6"
1.
° B
EN
D C
L
EL
=1
0.
4.21%
ST
A=
+7
8.
6"
1.
° B
EN
D C
L
EL
=1
8.
6" DIP FM
(CL 350) (TYP)
ST
A=
+6
9.
6"
1.
° B
EN
D C
L
EL
=1
2.
ST
A.
8+
.0
C
L
EL
=1
2.
(4 ° M
AX
D
EF
LE
C
TI
O N
2.24%
FO
FO
FO
FO
FO
FO
FO FO FO
FO FO FO FO FO
FO FO
FO FO FO FO FO FO FO FO FO FO
FO FO
FO
FO
FO
FOFO
FOFOFO
FO
FO
FO
FO
FO
G
G
G
G
G G
G G
G
G
G
G
G G G G G G G G G G G G G G G G G
GGGGGG
G
G
G
G
G
G G
UE UE
UE
UE
UE
UE
UE UE UE UE UE UE
UE
UE
UE
UE
UE
UE
UE UE UE
UE UE UE UE UE UE UE UE UE UE
UE UE UE UE UE UE UE UE UE UE UE UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE UE UE UE UE
UE
UE H
1161.41
HHC
1161.41
TPED -X
1161.28
TPED -X
1161.14
WM
1161.16
WM
1160.96
ICV
1160.43
MB-2860
8M
H
1161.13
HHC
1161.60
LPM -X 5231
1161.40
COSS
1160.37
MB - 2865
1159.79
COSS
1158.94
WM
12M
H
1158.86
HHC
1158.64
TPED -X
1158.61
TPED -X
1158.18
WM
1158.57
MHSD
1158.16
MB - 2870
1158.47
COSS
1158.43
MHSD
1156.92
WM
1156.69
WM
1156.59
ICV
H
1157.06
HHC
1153.30
TPED -X
1154.21
TPED -X
1154.60
TPED -X
1155.65
MB - 2880
1157.10
COSS
10M
H
1156.41
HHC
1151.10
MHSD
H
1153.94
HHC
1154.12
COSS
1153.90
TPED -X
1153.66
WM
1153.53
WM
1155.59
COSS
H
1154.57
HHC
1152.84
MB - 2890
1151.39
WM
1151.76
WM
H
1152.05
HHC
1152.42
LPM - X
1152.18
TPED5409
1151.94
TPED
1149.07
MHSD
1152.27
MB - 2895
.7
FH
-X
1152.24
COSS
1150.55
MB - 2910
1148.31
WM
1149.11
TPED
1149.09
MHSD
1150.00
COSS
1148.80
TPED
1148.64
TPEDH
1148.68
HHC
1148.51
WM
1148.52
WM
1148.46
ICV
1148.06
MB - 2925
55181147.33MB - 2920
1146.28
MB - 2935
H
1146.57
HHC
1147.26
COSS
1144.77
MHSD
1145.95
LPM
1145.63
SPS
1145.77
COSS
1144.75
WM
1144.63
WM
H
1145.59
HHC
1145.46
TPED
56451144.29MB - 3015
1144.48
COSS
1145.10
MHSD
.0
SP
S
1142.45
MHSD
.5
FH
-X
1143.83
EM -X
1143.22
MB - 3025
H
1142.48
HHC
1142.46
TPED -X
1142.21
ICV
1143.25
COSS
1142.50
WM
H
1142.65
HHC
1142.63
TPED -X
1142.68
TPED -X
1142.24
WM
1142.03
MB - 3035
1142.17
COSS
1142.49
LPM -X
1142.58
MHSD
1142.74 M
B - 3040
1140.99
MHSD
1140.83
MHSD
L.
L.
L.
L.
L.
L.
L.
L.
L.
L.
WHITFIELD AVENUE
(50' R/W PER PB 101, PG 188)
W
HI
TF
IE
LD
A
VE
NU
E (5
0' R
/W P
ER
P
B
1, P
G
8)
CARRICK ROAD
(50' R/W PER
PB 101, PG 188)
' D
OU
BL
E
SW
IN
G
GA
TE
EL
EC
TR
IC
CA
BI
NE
T
EL
EC
TR
IC
CA
BI
NE
T
W
AL
L
1/ 2"
R B
1/ 2"
R B
1/ 2"
R B
DI
ST
1/ 2"
R B
1/ 2"
R B
1/ 2"
R B
1/ 2"
R B
1/ 2"
R B
1/ 2"
C
TP
CO
NC
CO
NC
CO
NC
.CO
NC
CO
NC
CO
NC
CO
NC
CO
NC
CO
NC
CO
NC
CO
NC
CO
NC
CO
NC
CO
NC
CO
NC
CO
NC
CO
NC
CO
NC
CO
NC
AS
PH
AL
T
ASPHALT
ASPHALT
DW
CB
TO
P:
.9
I.O .(A
.9
I.I
.(B
.6
I.I .(C
.0
I.I
.(D
.8
(A
(B
(C
(D
E.
N.
L.
" C
MP
48" CMP
6" P
VC
DW
CB
TO
P:
.5
I.O .(A
.9
I.I
.(B
.8
I.I .(C
.9
I.I
.(D
.0
48" CMP
DW
CB
TO
P:
.8
I.O .(A
.0
I.I
.(B
.4
SW
CB
TO
P:
.4
I.O .:1
0.
(A
(B
" R
CP
E.
N.
L.
(A ) (B
(C
(D
CM
P
RC
P
42" CMP
E.
N.
L.
DW
CB
TO
P:
.7
I.O .(A
.7
I.I
.(B
.0
I.I .(C
.1
JB TO
P:
.1
I.O .(A
.0
I.I
.(B )1
8.
(A
) (B
" C
M P
30"
CMP
(A
(B
(C
JB TO
P:
.0
I.O .(A
.0
I.I
.(B )1
1.
I.I
.(C
.3
SW
CB
TO
P:
.0
I.O .(A
.8
I.I
.(B
.5
I.I .(C
.9
(A
" C
M P
(A
(B
(C
(A
(B
18" CMP
" C
M P
18"RCP
E.
N.
L.SW
CB
TO
P:
.1
I.O .(A
.7
I.I
.(B
.8
SW
CB
TO
P:
.4
I.O .(A
.2
I.I
.(B
.3
(A
(B
(B
(A
RC
P
" C
M P
E.
N.
L.
SW
CB
TO
P:
.5
I.O .(A
.6
I.I
.(B
.7
APPROXIMATE L.L.L. PER PB 101, PG 188
18" HDPE
FE
S
I.E .:1
5.
CM
P JB
TO
P:
.1
I.O .(A
.7
I.I
.(B
.9
HW
I.E
.:1
1.
OC
S
SE
E
OC
S
DE
TA
IL24
" C
MP
BE
NC
HM
AR
K
NA
IL
IN
C
ON
C.
EL
EV
. 1
7.
BE
NC
HM
AR
K
NA
IL
IN
C
ON
C.
EL
EV
. 1
5.
TOP OF BANK
E.
N.
L.
1/ 2"
R B
1134.13
MHSD
59021126.58HW
27K2K
24PO23K
19K
60171123.96HW
SS->SS->SS->SS->SS->SS->SS->SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS->
SS
SS->
SS->
W
W W
WW WWWWWW
W
W
W
W
WW
W W
W
W W W W W W
W
W
W
W
W
W W
W
W W W
W
WW
W
W W
W
W
W
W
W
W W W W W W W W
W
W
8" PVC
8" PVC
8" DIP
8" D
IP
8" DIP
8" DIP
8" D
IP
8" PVC
(A ) (B
SS
M
H
TO
P:
.3
I.O
.(A
.3
I.I .(B
.5
(A ) (B
SS
M
H
TO
P:
.7
I.O
.(A
.7
I.I .(B
.8
(A
(B
(C
SS
M
H
TO
P:
.8
I.O
.(A
.7
I.I .(B
.9
I.I
.(C
.0
(A
(B
(C
SS
M
H
TO
P:
.7
I.O
.(A
.9
I.I .(B
.0
I.I
.(C
.1
E.
N.
L.
E.
N.
L.
6"
PV
C8" P
VC
SS
M
H
TO
P:
.8
I.O
.(A
.9
I.I .(B
.9
(A
(B
(A
(B
(A
(B
(C
SS
M
H
TO
P:
.8
I.O
.(A
.5
I.I .(B
.6
I.I
.(C
.7
E.
N.
L.
(A ) (B
SS
M
H
TO
P:
.2
I.O
.(A
.0
I.I .(B
.1
8" PVC
8" DIP
6' WOODEN FENCE
6' W
OO
DE
N
FE
NC
E
HW
I.E
.:1
0.
DI
TC
H C/
L
RIP
RA
P
PO
ND
TR
EE
LI
NE
TR
EE
LI
NE
TR
EE
LI
NE
APPROXIMATE L.L.L. PER PB 18, PG 41
AP
PR
OX
IM
AT
E
L.
L.
L.
P
ER
P
B
, P G
1"
B
AR
1/ 2"
R B
G G
UE
G G
N/F
CAROLYN L. PELTIER
AND
GORDON J. PELTIER
P.I.N.:106 053
DB 5871, PG 265
LOT 12
PB 18, PG 41
N/F
WHITFIELD
PROPERTY OWNERS
ASSOCIATION, INC.
P.I.N.:106 628
DB 5373, PG 572
PB 101, PG 188 N/F
WHITFIELD SUBDIVISION
PB 101, PG 188
N/F
WHITFIELD SUBDIVISION
PB 101, PG 188
N/F
WHITFIELD SUBDIVISION
PB 101, PG 188
N/F
WHITFIELD SUBDIVISION
PB 101, PG 188
N/F
WHITFIELD SUBDIVISION
PB 101, PG 188
234567
4948474645
43424140
1158.95
IPF-4RB
1156.24
IPF-4RB
1152.61
IPF-4RB
1154.88
IPF-4RBD
1145.63
IPF-4RB
1144.40
IPF-4RB
1142.22
IPF-4RB
1154.08
IPF-4CTP
1143.74
IPF-4RB
1147.52
IPF-4RB
1145.91
IPF-4RB
1139.61
IPF-1IN BAR
20' SSE PER PB 101, PG 188
P/L
P/ L
P/ L
P/ L
P/
LP/
L
P/
LP/
L
P/
LP/
L
P/
LP/
L
P/L
P/L
P/L
P/
LP/
LP/
LP/
LP/
L
P/LP/LP/L
P/L
P/L
P/ L
P/L
P/ L
P/L
P/ L
P/L
P/L
P/ L
P/L
P/L
P/ L
P/ L
P/ L
P/L P/L
R/ W R/ W
R /W
R/W
R/ W
R/ W
R/W
R/W
R/W
R/W
D.E. PER PB 101, PG 188
D.E. PER PB 101, PG 188
D.E. PE
R PB
1, P
G 18
SS
M
H
TO
P:
.7
I.O
.(A
.5
I.I .(B
.6
" C
M P
E.
N.
L.
(C
(B
20' SSE PER PB 4112, PG 302
6" 45° BEND
STA 13+20.80
N 1514592.00 E 2290236.63
10+00
11+00
12+00
13+00
14+00 15+00 16+00
+00 18+00 19+00 20+00
6" 22.50° BEND
STA 13+44.84
N 1514571.30 E 2290224.39
6" 22.50° BEND
STA 15+86.82
N 1514330.78 E 2290234.86
6" 11.25° BEND
STA 15+59.10
N 1514358.49 E 2290235.47
6" 11.25° BEND
STA 16+44.25
N 1514280.51 E 2290207.64
6" 45° BEND
STA 16+94.22
N 1514231.15 E 2290202.36
6" 45° BEND
STA 17+09.11
N 1514220.71 E 2290212.97
6" DIP FM (CL 350)
6" 11.25° BEND
STA 10+24.81
N 1514874.37 E 2290148.30
6" 11.25° BEND
STA 16+69.02
N 1514256.36 E 2290202.14
6" 11.25° BEND
STA 16+16.85
N 1514305.54 E 2290218.80
6" 11.25° BEND
STA 15+94.21
N 1514324.02 E 2290231.88
6" 11.25° BEND
STA 14+78.32
N 1514438.01 E 2290221.25
STA 11+34.09
Δ 2.92° LT
N 1514769.32 E 2290178.43
STA 12+87.36
Δ 2.98° RT
N 1514624.33 E 2290228.12
STA 13+07.33
Δ 2.98° RT
N 1514605.12 E 2290233.60
STA 13+57.90
Δ 4.21° LT
N 1514558.38 E 2290222.50
STA 13+77.85
Δ 4.19° LT
N 1514538.48 E 2290221.08
6" DIP FM (CL 350)
SHEET
SEQ.
IS
SU
E
NO
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B
NO
FI
LE
N
AM
E
M
AY
AP
PR
OV
ED
CH
EC
KE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 4/29/2026 10:10 AM Plot By: CMiller Filename: C:\pw_working\carollo_200000\d0434344\203558_00C03.dwg
_0
0C
.d w g
La st
S av ed : 4
/2 9/
:4 d
By : C
M ill er Fi le na m e:
C :\p w _w or ki ng \c ar ol lo _2
0\ d0
\2
8_
C0 3.
dw g
AC
AD
R el
: 2 4.
3s (L
M S
Te ch
Ba r S ca le is o ne in ch o n or ig in al d ra w in g.
if no t o ne in ch o n th is sh ee t, ad ju st sc al e.
SITE DEVELOPMENT PLANS
.1
FO
RS
YT
H
CO
UN
TY
, G
EO
RG
IA
KE
NT
M
ER
E
LI
FT
S
TA
TI
ON
M
OD
IF
IC
AT
IO
NS
A
ND
F
OR
CE
M
AI
N
DE
SI
GN
Ca ro llo E ng in ee rs
, I nc
Ge or gi a Re gi st er ed
E ng in ee rin g
Fi rm
P
EF
-0
Ex pi re s 6
/3 0/
In te rs ta te N or th
P ar kw ay
Su ite
At la nt a, G
A
Ph on e
4)
-4
W eb w w w .fr ee se
.c om
0% F
IN
AL
D
ES
IG
N
GF
6/
/2
SI
TE
D
EV
EL
OP
M
EN
T
PL
AN
S
GF
5/
5/
80'40'0 20'
SCALE: 1" = 40' (HORIZ)
20'10'0 5'
SCALE: 1" = 10' (VERT)
M
AT
C H
L
IN
E
ST
A
+0
FO
R
C O
N
TI
N U
AT
IO
N S
EE
C
-4
M
AT
CH
L
IN
E
ST
A
+0
FO
R
CO
NT
IN
UA
TI
O N
SE
E
C-usanorth811.org
GJEPCMM
R
C-3
ST
A
+0
TO
0+
FO
RC
E
M
AI
N
PL
AN
A
ND
P
RO
FI
LE
CI
VI
L
10'
(MIN)
3.5'
18"
(MIN)
2.8'
3.1'
18"
(MIN)
18"
(MIN)4'
(MIN)
10' PERMANENT
EASEMENT
18"
(MIN)
MILL AND
OVERLAY LIMITS
OF PAVING
MILL AND
OVERLAY LIMITS
OF PAVING
PROTECT EX 6'
WOODEN FENCE
REPLACE
WOODEN 10'
SWING GATE
# KEY NOTES:
1. ALL PIPE JOINTS SHALL BE RESTRAINED
USING MECHANICAL JOINTS AND THRUST
BLOCKS PER DETAILS ON SHEETS C-8 AND C-9.
2. INSTALL PIPE UTILITY MARKERS PER DETAIL
ON SHEET C-8.
3. CONTRACTOR SHALL FIELD VERIFY THE
LOCATION, DEPTH, AND CONDITION OF ALL
EXISTING UTILITIES PRIOR TO BEGINNING
WORK. ANY DISCREPANCIES BETWEEN THE
PLAN AND ACTUAL SITE CONDITIONS MUST BE
REPORTED TO THE EOR IMMEDIATELY.
4. UTILITY PERMIT REQUIRED. CONTACT UTILITY
COORDINATOR MANAGER DAMON STANCIL AT
(770) 781-2165.
5. FORCE MAIN PIPE MUST BE INSTALLED IN
POLYETHYLENE ENCASEMENT WITHIN THE
FLOWABLE FILL EXTENTS.
18"
(MIN)
2 (TYP)
18"
(MIN)
C-6
C-6
210 LF OF FLOWABLE FILL ENCASEMENT
SAND FILTER
DIAPHRAM
C-8
SAND FILTER
DIAPHRAM
C-8
FLOWABLE FILL
ENCASEMENT
C-8
ST
A=
+0
ST
A=
+1
25' STREAM BUFFER
D ig ita lly s ig ne d by G in y
Ja co b C on ta ct In fo : C ar ol lo E ng in ee rs
, I nc
D at e:
6.
.0
:0
8:
-0 4'
20+00 21+00 22+00 23+00 24+00 25+00 26+00
EXISTING GROUND
42.0 LF
8" PVC SS (C900) @ 3.45%
EX
G
AS
IN
V U
N
KN
EX
E
LE
C
IN
V
U N
KN
EX
G
AS
IN
V U
N
KN
EX
4" S
D R
C P
IN
V
.9
EX
4" S
D R
C P
IN
V
.9
ST
A
+2
8.
SS
M
H
(B O
LT
ED
D O
W N
L
ID
IN
V
IN
3.
(6
" N
R
IM
0.
IN
V
O U
T
.9
(8
" S
ST
A
+4
6.
SS
M
H
(B O
LT
ED
D O
W N
L
ID
IN
V
IN
0.
(8
" N
R
IM
9.
IN
V
O U
T
.0
(8
" S E)
ST
A
+8
8.
EX
S
SM
H
IN
V
IN
8.
(8
" E
IN
V
IN
8.
(8
" N W
R
IM
8.
IN
V
O U
T
.3
(8
" S W
ST
A
+6
9.
EX
S
SM
H
IN
V
IN
4.
(8
" N E)
R
IM
3.
IN
V
O U
T
.8
(8
" W
180.4 LF EX 8" SS @ 1.88%
218.9 LF 8" PVC SS (C900) @ 5.80%
FLOWABLE FILL
ST
A=
+3
5.
6"
1.
° B
EN
D C
L
EL
=1
3.
ST
A=
+5
5.
6"
1.
° B
EN
D C
L
EL
=1
3.
0.13%
6" DIP FM
(CL 350)
FO
FO
FO
FO
G
G
G G G G G G G G G G G G G G G G G G G
G
G
G G
UE
UE
UE
UE UE UE UE UE UE UE UE UE UE UE
UE
UE
UE
UE
UE UE
UE
UE
.80
HW
.9
SP
S
12M 12M
12M
1151.92
LPM
9M
1157.71
SPS
12M
50931161.00SPS
1160.77
FH -X
1161.79
WM
1161.72
WM
H
1162.54
HHC
1162.48
SPS
1162.25
ICV
1162.23
TPED -X
1162.01
TPED -XH
1162.11
HHC
1162.03
WM
1162.12
WM
1162.42
MB -2850
51551162.35MB -2845
1161.71
MB-2855
1161.73
COSS
1158.75
ICV
H
1161.41
HHC
1161.41
TPED -X
1161.28
TPED -X
1161.14
WM
1161.16
WM
1160.96
ICV
1160.43
MB-2860
8M
H
1161.13
HHC
1161.60
LPM -X
1161.40
COSS
1160.37
MB - 2865
L.
L.
L.
L.
WHITFIELD AVENUE
(50' R/W PER PB 101, PG 188)
4' WOODEN FENCE
1/ 2"
R B
DI
ST
W
AL
L
CO
NC
CO
NC
CO
NC
CO
NC
CO
NC
ASPHALT ASPHALT
24"
RCP 24"
RCP
HW
SS->
.8
HW
SS
SS
SS
SS
SS->
SS->
W
W W
W
W
W
W W W W W W W W W W W W W W W W
W W
W W
W
W
W
SS
M
H
TO
P:
.1
I.O
.(A ):1
8.
I.I
.(B ):1
8.
SS
M
H
TO
P:
.8
I.O
.(A ):1
2.
I.I
.(B ):1
2.
SS
M
H
TO
P:
.9
I.O
.(A ):1
4.
I.I
.(B ):1
4.
(A
(B
(A
(B
(A
(B
E.
N.
L.
E.
N.
L.
E.
N.
L.
(A
(B
8" D
IP
8" D
IP
8"
DI
P
8" D
IP
UE
UE
1/ 2"
O
TP
1/ 2"
R B
SS
M
H
TO
P:
.4
I.O
.(A ):1
8.
I.I
.(B ):1
8.
HW I.E
.:1
3.
I.E
.:1
3.
4' W
OO
DE
N
FE
NC
E
I.E .:1
2.
I.E
.:1
2.
N/ F
SV
S
PL
AZ
A, L
LC
P.
I.N .:1
DB
1, P
G
N/F
WHITFIELD
PROPERTY OWNERS
ASSOCIATION, INC.
P.I.N.:106 628
DB 5373, PG 572
PB 101, PG 188
N/F
FATEMEH ASSARI
P.I.N.:106 074
DB 3349, PG 527
PB 7, PG 6
N/F
WHITFIELD SUBDIVISION
PB 101, PG 188
51 N/F
WHITFIELD
PROPERTY OWNERS
ASSOCIATION, INC.
P.I.N.:106 628
DB 5373, PG 572
PB 101, PG 188
1162.71
IPF-4RBD
1170.44
IPF-4OPT
' S
SE
P
ER
D
B
, P
G
20' D.E.
PE
R
PB
1, PG
' D
.E.
PE
R
PB
1, PG
AP
PA
RE
NT
0'
SS
E
P/L
P/ L
P/ L P/L
P/ L
P/L
P/L
P/L
P/L
P/L
P/L
P/LP/
L
P/ L
P/L
P/L
R /W
R /W R/W
R/W
R/W
R/W
20'
SSMH 1 (BOLTED DOWN LID)
STA 21+28.04
N 1513806.99 E 2290247.60
SSMH 2 (BOLTED DOWN LID)
STA 23+46.98
N 1513598.02 E 2290312.93
EX SSMH 1
STA 23+88.98
N 1513568.03 E 2290342.34
8" PVC SS (C900)
8" PVC SS (C900)
20+00 21+00 22+00 23+00
24+00
25+00
25+69.38
6" 11.25° BEND
STA 20+35.52
N 1513894.34 E 2290217.85
6" 11.25° BEND
STA 20+55.21
N 1513875.00 E 2290221.57
6" DIP FM (CL 350)
SHEET
SEQ.
IS
SU
E
NO
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B
NO
FI
LE
N
AM
E
M
AY
AP
PR
OV
ED
CH
EC
KE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 4/29/2026 10:24 AM Plot By: CMiller Filename: C:\pw_working\carollo_200000\d0434344\203558_00C04.dwg
_0
0C
.d w g
La st
S av ed : 6
/2 7/
1:
d By
: C M ill er
Fi le na m e:
C
:\p w
_w or ki ng
\c ar ol lo
_2
0\ d0
\2
8_
C0
4.
dw g
AC
AD
R el : 2
4.
3s
(L M
S Te ch
Ba r S ca le is o ne in ch o n or ig in al d ra w in g.
if no t o ne in ch o n th is sh ee t, ad ju st sc al e.
SITE DEVELOPMENT PLANS
.1
FO
RS
YT
H
CO
UN
TY
, G
EO
RG
IA
KE
NT
M
ER
E
LI
FT
S
TA
TI
ON
M
OD
IF
IC
AT
IO
NS
A
ND
F
OR
CE
M
AI
N
DE
SI
GN
Ca ro llo E ng in ee rs
, I nc
Ge or gi a Re gi st er ed
E ng in ee rin g
Fi rm
P
EF
-0
Ex pi re s 6
/3 0/
In te rs ta te N or th
P ar kw ay
Su ite
At la nt a, G
A
Ph on e
4)
-4
W eb w w w .fr ee se
.c om
0% F
IN
AL
D
ES
IG
N
GF
6/
/2
SI
TE
D
EV
EL
OP
M
EN
T
PL
AN
S
GF
5/
5/
80'40'0 20'
SCALE: 1" = 40' (HORIZ)
20'10'0 5'
SCALE: 1" = 10' (VERT)
M
AT
C H
L
IN
E
ST
A
+0
FO
R
C O
N
TI
N U
AT
IO
N S
EE
C
-3 usanorth811.org
GJEPCMM
R
C-4
ST
A
+0
TO
E
ND
FO
RC
E M
AI
N
AN
D
GR
AV
IT
Y
PL
AN
A
ND
P
RO
FI
LE
CI
VI
L
5.5'
MILL AND OVERLAY
LIMITS OF PAVING
2'-6"
INSTALL MANHOLE
VENT ASSEMBLY
W/ODOR CONTROL
C-8
# KEY NOTES:
1. SEE DETAIL 14 FOR FORCE MAIN TO GRAVITY
SEWER TRANSITION AND DETAIL CS110 POLYMER
CONCRETE MANHOLE.
2. SEE DETAIL CS110 POLYMER CONCRETE MANHOLE.
3. LIMITS OF FLOWABLE FILL IN PLAN IS THE WIDTH
OF THE TRENCH.
4. ALL PIPE JOINTS SHALL BE RESTRAINED USING
MECHANICAL JOINTS AND THRUST BLOCKS PER
DETAILS ON SHEET C-8 AND C-9.
5. CONTRACTOR SHALL FIELD VERIFY THE LOCATION,
DEPTH, AND CONDITION OF ALL EXISTING UTILITIES
PRIOR TO BEGINNING WORK. ANY DISCREPANCIES
BETWEEN THE PLAN AND ACTUAL SITE
CONDITIONS MUST BE REPORTED TO THE EOR
IMMEDIATELY.
6. CONNECTION TO EXISTING MANHOLE SHALL BE
PERFORMED ONLY BY MEANS OF CORE DRILLING,
IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS FOR INSTALLING A NEOPRENE
BOOT, LINK SEAL, OR EQUAL. FLEXIBLE
CONNECTORS SHALL CONFORM TO ASTM C923,
LATEST REVISION.
7. UTILITY PERMIT REQUIRED. CONTACT UTILITY
COORDINATOR MANAGER DAMON STANCIL AT (770)
781-2165.
C-6
176.43°
152.92°
D ig ita lly s ig ne d by G in y
Ja co b C on ta ct In fo : C ar ol lo E ng in ee rs
, I nc
D at e:
6.
.0
:0
1:
-0 4'
MAXIMUM TRENCH DEPTHS, D.I.P.
FORSYTH COUNTY DEPARTMENT OF WATER AND SEWER
DETAIL TITLE:
DRAWN BY:
DATE:
SCALE: N.T.S.
SEPT. 12, 2005
34.0
DETAIL NO. BEDDING FOR DUCTILE IRON PIPE
FORSYTH COUNTY DEPARTMENT OF WATER AND SEWER
DETAIL TITLE:
DRAWN BY:
DATE:
SCALE: N.T.S.
SEPT. 12, 2005
33.0
DETAIL NO.
SHEET
SEQ.
IS
SU
E
NO
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B
NO
FI
LE
N
AM
E
M
AY
AP
PR
OV
ED
CH
EC
KE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 4/29/2026 10:29 AM Plot By: CMiller Filename: C:\pw_working\carollo_200000\d0434344\203558_00C05.dwg
_0
0C
.d w g
La st
S av ed : 6
/2 7/
1:
d By
: C M ill er
Fi le na m e:
C
:\p w
_w or ki ng
\c ar ol lo
_2
0\ d0
\2
8_
C0
5.
dw g
AC
AD
R el : 2
4.
3s
(L M
S Te ch
Ba r S ca le is o ne in ch o n or ig in al d ra w in g.
if no t o ne in ch o n th is sh ee t, ad ju st sc al e.
SITE DEVELOPMENT PLANS
.1
FO
RS
YT
H
CO
UN
TY
, G
EO
RG
IA
KE
NT
M
ER
E
LI
FT
S
TA
TI
ON
M
OD
IF
IC
AT
IO
NS
A
ND
F
OR
CE
M
AI
N
DE
SI
GN
Ca ro llo E ng in ee rs
, I nc
Ge or gi a Re gi st er ed
E ng in ee rin g
Fi rm
P
EF
-0
Ex pi re s 6
/3 0/
In te rs ta te N or th
P ar kw ay
Su ite
At la nt a, G
A
Ph on e
4)
-4
W eb w w w .fr ee se
.c om
0% F
IN
AL
D
ES
IG
N
GF
6/
/2
SI
TE
D
EV
EL
OP
M
EN
T
PL
AN
S
GF
5/
5/
GJEPBDM
A
C-5
CI
VI
L S
TA
ND
AR
D
DE
TA
IL
S I
CI
VI
L
SCALE:
DETAIL1
- NO SCALE SCALE:
DETAIL2
- NO SCALE SCALE:
DETAIL3
- NO SCALE
SCALE:
DETAIL5
- NO SCALE
6" WALL ANCHOR
THRUST RESTRAINT
NOTES:
1. f'c = 4000 PSI @ 28 DAYS.
2. ALL REINFORCING STEEL TO BE ASTM A-615 GRADE 60.
3. CARRY ALL BEARING SURFACES TO FIRM SUBGRADE. PLACE
CONCRETE ANCHOR AGAINST DOWNGRADE SIDE OF BELL.
6-#5 BARS
6-#5 BARS
4-#5 STIRRUPS
@ 10" C/C/ MAX
40'
"A"
MINIMUM
9" 9"
"B"
MINIMUM
PIPE
DIAMETER
PIPE
SLOPE
MAXIMUM
SPACING
≤ 12"
SLOPE
VARIES
20% TO 35%
20' 18" 18"35% TO 49%
40' 12" 12"
14" TO 24"
20% TO 35%
20' 24" 24"35% TO 49%
2'-0"
1- 0"
(M
IN
(MIN)
1- 0"
(M
IN
TRENCH
WIDTHFINISH
GRADEA
B (MIN)B (MIN)
A (M
IN
A (M
IN
EQ
U
AL
EQ
U
AL
EQUAL EQUAL
3" C
LE
AR
(T
YP
3" CLEAR (TYP)
4-#5 STIRRUPS
@ 10" C/C/ MAX
(2 TOP, 2 BOT)
TYPICAL OF 4
BOTTOM
OF TRENCH
SCALE:
DETAIL6
- NO SCALE
CONCRETE ANCHOR
A SECTION
SCALE:
DETAIL4
- NO SCALE
LOCATING WIRE
(SEE NOTE 4)
LOCATING WIRE
(SEE NOTE 4)
WARNING TAPE
(SEE NOTE 5)
WARNING TAPE
(SEE NOTE 5)
D ig ita lly s ig ne d by G in y
Ja co b C on ta ct In fo : C ar ol lo E ng in ee rs
, I nc
D at e:
6.
.0
:0
3:
-0 4'
SCALE:
DATE:
DRAWN BY:
VALVE BOX
FORSYTH COUNTY DEPARTMENT OF WATER AND SEWER
DETAIL TITLE:
N.T.S.
SEPT. 12, 2005
13.0
DETAIL NO.
SECTION
NOTES:
PAVEMENT TABLE
SHEET
SEQ.
IS
SU
E
NO
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B
NO
FI
LE
N
AM
E
M
AY
AP
PR
OV
ED
CH
EC
KE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 4/29/2026 10:30 AM Plot By: CMiller Filename: C:\pw_working\carollo_200000\d0434344\203558_00C06.dwg
_0
0C
.d w g
La st
S av ed : 6
/2 7/
1:
d By
: C M ill er
Fi le na m e:
C
:\p w
_w or ki ng
\c ar ol lo
_2
0\ d0
\2
8_
C0
6.
dw g
AC
AD
R el : 2
4.
3s
(L M
S Te ch
Ba r S ca le is o ne in ch o n or ig in al d ra w in g.
if no t o ne in ch o n th is sh ee t, ad ju st sc al e.
SITE DEVELOPMENT PLANS
.1
FO
RS
YT
H
CO
UN
TY
, G
EO
RG
IA
KE
NT
M
ER
E
LI
FT
S
TA
TI
ON
M
OD
IF
IC
AT
IO
NS
A
ND
F
OR
CE
M
AI
N
DE
SI
GN
Ca ro llo E ng in ee rs
, I nc
Ge or gi a Re gi st er ed
E ng in ee rin g
Fi rm
P
EF
-0
Ex pi re s 6
/3 0/
In te rs ta te N or th
P ar kw ay
Su ite
At la nt a, G
A
Ph on e
4)
-4
W eb w w w .fr ee se
.c om
0% F
IN
AL
D
ES
IG
N
GF
6/
/2
SI
TE
D
EV
EL
OP
M
EN
T
PL
AN
S
GF
5/
5/
GJEPCMM
A
C-6
CI
VI
L S
TA
ND
AR
D
DE
TA
IL
S
II
CI
VI
L
SCALE:
DETAIL10
- NO SCALE
SCALE:
DETAIL8
- NO SCALE SCALE:
DETAIL9
- NO SCALE
FLOW METER VAULT
6'-0"
6' -0
12"
(MIN)
12"
(MIN)
6" OR 8" RESTRAINED
DISMANTLING JOINT
(TYP)
6" OR 8" MAG METER
2'-0"
(TYP)
3'-6"x3'-6" AL HATCH
(ABOVE)
3'-6"x3'-6" AL HATCH
2' -6
2'-0"
(TYP)
PRECAST
CONC VAULT
MH RUNG
6" OR 8" MAG METER
6" OR 8" RESTRAINED
DISMANTLING JOINT
(TYP)
PRECAST
CONC VAULT
WATERSTOP
GASKET BY PIPE
MFR (TYP)
6" OR 8" FM
6" OR 8" FM
6" OR 8" FM6" OR
8" FM
12"
(MIN)
PLAN
A SECTION
A
FINISHED
GRADE
6" 3'
-0
MH RUNG
NOTES:
1. PROVIDE UPSTREAM AND DOWNSTREAM STRAIGHT
PIPE RUNS AS REQUIRED BY THE METER SUPPLIER.
2. PROVIDE 18" CLEARANCE FROM CENTERLINE OF
PIPE TO FLOOR AND 12" MINIMUM CLEARANCE
BETWEEN FLANGES AND VAULT SIDEWALLS.
3. MAG FLOW METER. FURNISH AND INSTALL 1"C
EMPTY FROM MAG FLOW METER LOCATION TO MAG
METER PIT FOR SENSOR WIRE. VERIFY EXACT
LOCATION PRIOR TO ANY ROUGHING. INSTALL WIRE
FROM SENSOR TO TRANSMITTER AS REQUIRED.
SECTION
PAVEMENT TABLE
SCALE:
DETAIL11
- NO SCALE
LONGITUDINAL ROADWAY CUT FINAL BACKFILL
SCALE:
DETAIL12
- NO SCALE
MILLING AND OVERLAY
12"x12"x12" SUMP PIT
W/ GRATE
1% SLOPE
12"x12"x12" SUMP PIT W/ GRATE
(NOT IN SECTION SHOWN FOR CLARITY)
12"
(MIN) TYP
MP035
4"
3' M
IN
IM
U M
2' X 2'
TOP OF GRADE
RE: CIVIL SHEETS
ACTUATOR (NOTE 1)
T316 SS NECK
EXTENSION (MIN DIAMETER
TO BE SIZED BY MFR)
3000 PSI CONCRETE (CLASS B)
VALVE ACTUATOR PAD
NOTE: REFER TO THE ELECTRICAL SHEETS FOR POWER REQUIREMENTS
#4 REBAR EACH
SIDE
SCALE:
DETAIL7
- NO SCALE
ACTUATOR AND VALVE PAD
D ig ita lly s ig ne d by G in y
Ja co b C on ta ct In fo : C ar ol lo E ng in ee rs
, I nc
D at e:
6.
.0
:0
1:
-0 4'
FORCEMAIN CONNECTION
DETAIL TITLE:
DRAWN BY:
DATE:
SCALE: N.T.S.
SEPT. 12, 2005
45.0
DETAIL NO.
TRAFFIC FRAME AND COVER
FORSYTH COUNTY DEPARTMENT OF WATER AND SEWER
DETAIL TITLE:
DRAWN BY:
DATE:
SCALE: N.T.S.
SEPT. 12, 2005
46.0
DETAIL NO.
AIR/VACUUM RELEASE VALVE
FORSYTH COUNTY DEPARTMENT OF WATER AND SEWER
DETAIL TITLE:
DRAWN BY:
DATE:
SCALE: N.T.S.
SEPT. 12, 2005
20.0
DETAIL NO.
FOR 2" AND SMALLER
SHEET
SEQ.
IS
SU
E
NO
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B
NO
FI
LE
N
AM
E
M
AY
AP
PR
OV
ED
CH
EC
KE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 4/29/2026 10:31 AM Plot By: CMiller Filename: C:\pw_working\carollo_200000\d0434344\203558_00C07.dwg
_0
0C
.d w g
La st
S av ed : 6
/2 7/
1:
d By
: C M ill er
Fi le na m e:
C
:\p w
_w or ki ng
\c ar ol lo
_2
0\ d0
\2
8_
C0
7.
dw g
AC
AD
R el : 2
4.
3s
(L M
S Te ch
Ba r S ca le is o ne in ch o n or ig in al d ra w in g.
if no t o ne in ch o n th is sh ee t, ad ju st sc al e.
SITE DEVELOPMENT PLANS
.1
FO
RS
YT
H
CO
UN
TY
, G
EO
RG
IA
KE
NT
M
ER
E
LI
FT
S
TA
TI
ON
M
OD
IF
IC
AT
IO
NS
A
ND
F
OR
CE
M
AI
N
DE
SI
GN
Ca ro llo E ng in ee rs
, I nc
Ge or gi a Re gi st er ed
E ng in ee rin g
Fi rm
P
EF
-0
Ex pi re s 6
/3 0/
In te rs ta te N or th
P ar kw ay
Su ite
At la nt a, G
A
Ph on e
4)
-4
W eb w w w .fr ee se
.c om
0% F
IN
AL
D
ES
IG
N
GF
6/
/2
SI
TE
D
EV
EL
OP
M
EN
T
PL
AN
S
GF
5/
5/
GJEPCMM
A
C-7
CI
VI
L S
TA
ND
AR
D
DE
TA
IL
S
III
CI
VI
L
SCALE:
DETAIL13
- NO SCALE SCALE:
DETAIL14
- NO SCALE SCALE:
DETAIL15
- NO SCALE
SCALE:
DETAIL16
- NO SCALE
3' -0
D ig ita lly s ig ne d by G in y
Ja co b C on ta ct In fo : C ar ol lo E ng in ee rs
, I nc
D at e:
6.
.0
:0
9:
-0 4'
MANHOLE VENT ASSEMBLY
DETAIL TITLE:
DRAWN BY:
DATE:
SCALE: N.T.S.
SEPT. 12, 2005
43.0
DETAIL NO.
DRAWN BY:
SCALE:
DATE:
PIPE UTILITY MARKER
FORSYTH COUNTY DEPARTMENT OF WATER AND SEWER
N.T.S.
JUNE 13, 2025 DETAIL TITLE:
73.0
DETAIL NO.
2' -0
(M
IN
NOTE:
1. SAND FILTER DIAPHRAGM TO CONFORM WITH ASTM C-33 SAND / GDOT #10 SAND.
SECTION
PLANFORCE MAIN
12"
(MIN)
12"
(MIN)
SAND FILTER DIAPHRAGM
(SEE NOTE 1)
TRENCH WIDTH
12"
(MIN)
12"
(MIN)
(M
IN
2'
-0
(M
IN
(M
IN
SAND FILTER DIAPHRAGM
(SEE NOTE 1)
FINISHED GRADE
FLOWABLE FILL (TYP)
(SEE DETAIL 22)
FORCE MAIN
UNDISTURBED
EARTH (TYP)
UNDISTURBED
EARTH (TYP)
EQUAL TO
12" ALL AROUND
TRENCH WIDTH
UNDISTURBED
EARTH (TYP)
BACKFILL
REQUIREMENTS
(SEE NOTE 2)
NOTES:
1. CONCRETE ENCASEMENT SHALL BE USED ON SANITARY SEWER FORCE MAIN PIPING WHERE
INSTALLATION CANNOT MAINTAIN MINIMUM 10 FEET SEPARATION FROM POTABLE WATER LINES.
2. REMAINING TRENCH DEPTH ABOVE FLOWABLE FILL SHOULD BE BACKFILLED WITH CLAYEY SOIL (USCS TYPE SM, SC, ML, MH, CL, OR CH) WITH A MINIMUM FINES CONTENT OF 30% AND PLASTIC
INDEX 5. THE EARTHFILL SHOULD BE COMPACTED USING A SHEEPSFOOTED VIBRATORY TRENCH
COMPACTOR IN 6-INCH LIFTS TO 95% STANDARD PROCTOR DENSITY AND AT 0 TO 3% ABOVE THE
OPTIMUM MOISTURE CONTENT,
3. DIP FORCE MAIN PIPE MUST BE POLYETHYLENE ENCASED WITHIN FLOWABLE FILL ENCASEMENT.
FLOWABLE FILL
(MIN STRENGTH 100 PSI)
FORCE MAIN
(SEE NOTE 3)
SHEET
SEQ.
IS
SU
E
NO
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B
NO
FI
LE
N
AM
E
M
AY
AP
PR
OV
ED
CH
EC
KE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 5/1/2026 3:00 PM Plot By: CMiller Filename: C:\pw_working\carollo_200000\d0434344\203558_00C08.dwg
_0
0C
.d w g
La st
S av ed : 5
/1 /2
2:
P d
By : C
M ill er Fi le na m e:
C :\p w _w or ki ng \c ar ol lo _2
0\ d0
\2
8_
C0 8.
dw g
AC
AD
R el
: 2 4.
3s (L
M S
Te ch
Ba r S ca le is o ne in ch o n or ig in al d ra w in g.
if no t o ne in ch o n th is sh ee t, ad ju st sc al e.
SITE DEVELOPMENT…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .