This document contains air cleaner and filter specifications for the Department of State's European Logistics Support Office (ELSO). The key requirements include:

220/240V - 50/60 Hz power with European 'Schuko' plug, a minimum Clean Air Delivery Rate (CADR) of 240 cubic feet per minute, True HEPA filtration, maximum noise levels of 40/60 decibels, replaceable filters, and portability as a free-standing floor model. The air cleaners must also be ENERGY STAR certified and meet ozone emission standards. Specific models required are the Bluair Pro M for 200-400 sq ft rooms and the Bluair 405 for 400-600 sq ft rooms, with proposed models required to cover the contract period.

This specification is associated with a Department of State Request for Information (RFI) for air purification products for overseas use. The RFI is for market research purposes only and does not intend to result in a contract award.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Air Cleaner & Filter Specifications

The Department of State's European Logistics Support Office (ELSO) requires 220/40V, 50/60HZ air cleaners and filters with the following specifications:

No. General Requirements P/F 1 220/240V - 50/60 Hz 2 European 'Schuko' plug (Type F) 3 Clean Air Delivery Rate (CADR) of at least 240 cubic feet per minute (CFM) 4 True High Efficiency Particulate Air (HEPA) filtration (captures 99.97 percent of particles as small as 0.3 microns) or better

5 Not excessively noisy. Operate at maximum 40 decibels on lower setting and maximum of 60 decibels (dB) on highest setting measured 5 feet directly in front of air cleaner

6 A variable switch (preferred) or automatic restart 7 No air cleaners with “permanent” filters. Filters must be replaceable.

8 Portable free standing floor model out of the box (no assembly required). No wall or ceiling units

9 Air cleaners that may emit ozone must be tested for electrical safety and ozone emissions, and meet an ozone emission concentration limit of 0.050 parts per million through tests outlined in UL Standard 867 Section 37.1.20. Certification by the California Environmental Protection Agency Air Resources Board (see http://www.arb.ca.gov/research/indoor/aircleaners/certified.htm ) Listing on this site is considered documentation of this requirement.

10 ENERGY STAR® designation or determined to meet ENERGY STAR® criteria by an organization recognized by the U.S. EPA as a Certification Body (CB) an approved to administer verification testing for purposes of the ENERGY STAR® program. For example, AHAM (see http://ahamverifide.org/search-for-products/room-air-cleaners/ )

No. Specific Requirements P/F 1 The medium air cleaner and associated filters must be able to operate at maximum efficiency and suitable for a room 200-400 square feet (Brand Name or Equal to the Bluair Pro M).

2 The large air cleaner and associated filters must be able to operate at maximum efficiency and suitable for a room 400-600 square feet (Brand Name or Equal to the Bluair 405).

*Proposed models must have a lifecycle that covers the contract period of performance.