1-5835-005 MontgomeryParkADA Drawings IFB.pdf
PDF 4 MB Posted
- Solicitation number
- US.258297
- Issued by
- Lycoming County, Pennsylvania
About this file
This file contains architectural bidding drawings for the Montgomery Park ADA Bathroom – Interior Improvement Project prepared by Larson Design Group for Montgomery Borough, Pennsylvania, located at 119 1st Street, Montgomery, PA 17752. The drawings, issued for bidding on October 19, 2026, depict interior improvements for bathroom accessibility modifications in compliance with Americans with Disabilities Act (ADA) standards. The document includes general notes and legends detailing specific ADA compliance requirements for casework, appliances, doors, hardware, shelves, closets, thresholds, level changes, protruding objects, and reach requirements. Key specifications include storage accessibility standards (ANSI 804.5), appliance accessibility requirements (ANSI 804.6), fixture height limitations not to exceed 34 inches, door hardware specifications requiring lever-type devices mounted at 34 to 48 inches above finished floor with maximum 5-pound effort to operate interior doors, and detailed ramp specifications with minimum 36-inch clear width and maximum 38-inch height. The drawings establish precise measurements for reach requirements, clear floor spaces, and accessible routes throughout the facility.
The bidding drawings reference Project No. 5835-005 and include detailed dimensional specifications and compliance standards necessary for contractors to prepare accurate construction bids. These technical drawings serve as the basis for the sealed bid solicitation, with bids due electronically via PennBid by 11:00 A.M. on November 20, 2026, and a pre-bid conference scheduled for November 5, 2026, at the Montgomery Borough Office. The drawings confirm that this is an interior improvement project focused exclusively on ADA bathroom accessibility compliance, with no exterior construction or site work elements included.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2-5835-005 MontgomeryParkADA Project Manual IFB.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MA
RK
DA
TE
CO
MM
EN
TS
© Larson Design Group 2026
P:
\58
\58
-0
\P ar k B ath ro om A
DA
P ro jec t\D W
G\
-0
_C
-1
.dw g, G-
1 -
IN
T, /19 /20
7:
:33
A M, F os ter , K ay ley
Project No.:
Sheet No.:
Date:
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
SEAL
3000 WESTINGHOUSE DRIVE
SUITE 400
CRANBERRY TWP, PA 16066
(877) 323-6603
Larson Design Group
5835-005
MO
NT
GO
ME
RY
P
AR
K
BA
TH
RO
OM
A
DA
9 F
IR
ST
S
TR
EE
, M
ON
TG
OM
ER
Y, P
A
10-19-2026
IS
SU
ED
F
OR
B
ID
DI
NG
MO
NT
GO
ME
RY
B
OR
OU
GH
S
OU
TH
M
AI
N
ST
RE
ET
MO
NT
GO
ME
RY
, P A
-1 9-
IS
SU
ED
F
OR
B
ID
DI
NG
IN
TE
R
IO
R
IM
PR
O
VE
M
EN
TS
G-001
C O
VE
R
S H
EE
T
MONTGOMERY BOROUGH
35 SOUTH MAIN STREET
MONTGOMERY, PA 17752
BIDDING DRAWINGS
MONGOMERY PARK BATHROOM ADA - INTERIOR IMPROVEMENTS
119 1ST STREET, MONTGOMERY, PA 17752
5835-005
MA
RK
DA
TE
CO
MM
EN
TS
© Larson Design Group 2026
P:
\58
\58
-0
\P ar k B ath ro om A
DA
P ro jec t\D W
G\
-0
_C
-1
.dw g, G-
2, /19 /20
7:
:10
A M, F os ter , K ay ley
Project No.:
Sheet No.:
Date:
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
SEAL
3000 WESTINGHOUSE DRIVE
SUITE 400
CRANBERRY TWP, PA 16066
(877) 323-6603
Larson Design Group
5835-005
MO
NT
GO
ME
RY
P
AR
K
BA
TH
RO
OM
A
DA
9 F
IR
ST
S
TR
EE
, M
ON
TG
OM
ER
Y, P
A
10-19-2026
IS
SU
ED
F
OR
B
ID
DI
NG
MO
NT
GO
ME
RY
B
OR
OU
GH
S
OU
TH
M
AI
N
ST
RE
ET
MO
NT
GO
ME
RY
, P A
-1 9-
IS
SU
ED
F
OR
B
ID
DI
NG
IN
TE
R
IO
R
IM
PR
O
VE
M
EN
TS
G-002
G
EN
ER
A
L N
O
TE
S A
N D
L
EG
EN
D
FEMA FIRM MAP
MAP NUMBER:
USGS QUADRANGLE MAP
MAP SCALE:
MAP SCALE:
MAP SCALE:
X
FM
G
S
W
SFF
LOD
PERMIT
E
T
V
CS-8
CS-12
CS-18
CS-24
OH
1" = 2000'
1" = 500' 42081C0516F
MUNCY
NOTES:
1. 50% OF ALL STORAGE MUST BE ACCESSIBLE AND MEET REACH
REQUIREMENTS (ANSI 804.5).
2. FORWARD APPROACH KNEE AND TOE CLEARANCE NOT REQUIRED
FOR KITCHEN SINKS WHERE A COOK TOP OR RANGE IS NOT
PROVIDED OR AT WET BARS (ANSI 606.2).
3. APPLIANCES MUST BE ACCESSIBLE (ANSI 804.6).
4. LAVATORY, SINK AND OTHER FIXTURES MUST NOT EXCEED 34" IN
HEIGHT. VERIFY EXACT FIXTURE DIMENSIONS PRIOR TO
FABRICATION & INSTALLATION OF CABINETRY AND COUNTERTOP.
SEE NOTE #1
SEE NOTE #3 SEE NOTE #4
FORWARD APPROACH
REQUIREMENTS (SEE NOTE #2)
50% OF REFRIGERATOR/FREEZER
MUST BE 54% MAX HEIGHT AFF
(ANSI 804.6.6)
" M
AX
" M
AX
30" CLR
" M
AX
" M
AX
" M
AX
CASEWORK AND APPLIANCES DOORS AND HARDWARE
DOOR TYPE:
1. MINIMUM 10" HIGH SMOOTH SURFACE AT DOOR BOTTOM, EITHER ATTACHED PANEL OR
BOTTOM RAIL.
HARDWARE:
1. OPENABLE FROM INSIDE WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT.
2. OPENABLE BY SINGLE EFFORT LEVER-TYPE DEVICE (NOT REQUIRING GRASPING).
3. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE HARDWARE TO BE MOUNTED
AT 34"
4. MAXIMUM 8.5 LBS EFFORT TO OPERATE EXTERIOR DOOR; 5 LBS FOR INTERIOR DOOR.
(WHERE INDICATED)
A NARROW FRAME WITH A
BEVELED TOP EDGE
(60) DEGREE MAXIMUM BEVEL TO
HORIZONTAL PLANE)
INSTALLED AT THE BOTTOM OF A
GLASS DOOR
(WITH NO SIDE FRAMES) MAY BE
USED IN LIEU OF PROVIDING THE
REQUIRES 10-INCH
UNINTERRUPTED SURFACE AT THE
BOTTOM OF THE DOOR.
LEVER OR U
SHAPED HANDLE
MOUNTED AT 34"
TO 48" AFF
BO
T
R
AI
L
" M
IN
21" MAX 21" MAX
M
IN
9"
" M
AX
> 10"
SHELVES AND CLOSETS
THRESHOLD AND LEVEL CHANGES
COMPRESSED CARPET 1/4"
MAX BELOW THRESHOLD
THRESHOLD
FIN FLOOR
LEVEL
PI
LE
H
EI
G H
T 1/
2" M
IN
TRANSITION BETWEEN FLOOR FINISHES
DOOR THRESHOLD
1/ 4"
M
AX
1/ 2"
M
AX
11/
4" M
AX
1/ 2"
M
AX
LEVEL CHANGES
NOTES:
1. 1/2" MAXIMUM TOTAL HEIGHT WITH 1.4" MAXIMUM VERTICAL
CHANGE AT EDGE.
2. 1:2 SLOPED BEVEL REQUIRED IF LEVEL CHANGE IS OVER 1/4"
VERTICAL.
3. LEVEL CHANGES OF MORE THAN 1/2" MUST BE RAMPED AND
COMPLY WITH RAMP REQUIREMENTS.
PROTRUDING OBJECTS
" M
IN
4" MAX
>2 7"
FIG (A)
" M
AX
FIG (B)
WIDTH
ACCESSIBLE AMOUNT
ANY
FIG (C)
" M
AX
CANE RANGE
FIG (D)
" M
AX
CANE RANGE
POST
12" MAX
REACH REQUIREMENTS
" M
AX
48"
" M
IN
HIGH FORWARD REACH LIMIT
48"
NOTES:
1. X MUST BE < 25 INCHES; Z MUST BE > X.
2. WHEN X < 20 INCHES, THEN Y MUST BE 48 INCHES MAX.
3. WHEN X IA > 20 TO 25 INCHES, THEN Y MUST BE 44 INCHES MAX.
MAXIMUM FORWARD REACH OVER AN OBSTRUCTION
(X)
(Y
(Z)
(Z)
30"
" M
IN
" M
AX
CLEAR FLOOR SPACE PARALLEL APPROACH HIGH AND LOW SIDE REACH LIMITS
" M
AX
SIDE REACH OVER AN OBSTRUCTION
" M
AX
10" MAX 30"
" M
AX
" M
AX
24" MAX
>10" MIN
30"
RAMPS
PLACE BOTTOM RAIL SO THAT
A 4" DIA SPHERE CANNOT
PASS THROUGH THE RAILING
UP TO 4" ABOVE RAMP
" M
IN
36" MIN CLEAR
" M
AX
" M
IN
<4
NO BOTTOM RAIL IS
REQUIRED WHEN EDGES OF
RAMP EXTEND 12" MIN FROM
THE INSIDE OF THE RAILING
" M
IN
36" MIN CLEAR
" M
AX
" M
IN
12" MIN
RAMP SECTIONSTRAIGHT RAMP RUN
NOTE:
ALL RAMPS MUST MEET HANDRAIL AND CURB REQUIREMENTS.
WHEN DOOR, DISTANCES
MUST COMPLY WITH ADA
DOOR CLEARANCES
60" MIN
60" MIN
60"
MIN
60"
MIN
360" INTERVAL MAX
VARIES
360" INTERVAL MAX
VARIES
AS REQUIRED
30" MAX
RISE, TYP
WHEN DOOR, DISTANCES
MUST COMPLY WITH ADA
DOOR CLEARANCES
60" MIN
60" MIN
60"
MIN
AS REQUIRED
RAMP WITH INTERMEDIATE
SWITCH-BACK PLATFORM
30" MAX RISE, TYP
60" MIN
WHEN DOOR, DISTANCES
MUST COMPLY WITH ADA
DOOR CLEARANCES
60" MIN
60" MIN
60"
MIN
60"
MIN
360" INTERVAL MAX
VARIES
360" INTERVAL MAX
VARIES
60" MIN LANDING
30" MAX RISE, TYP
INTERMEDIATE
TURNING POSITION
RAMP WITH TURNING PLATFORM
AS REQ'D
60" MIN
INTERMEDIATE
PLATFORM
SIDEWALK DETAIL
POLE
CURB,
TYP
STREET,
TYP
SIDEWALKSIDEWALK
CLEAR
36" MIN
CLEAR
48" MIN
CLEAR
48" MIN
CLEAR
36" MIN
" M
AX
" M
IN 38
" M
AX
" M
IN
MIN
12" MIN
12"
RAMP HANDRAIL EXTENSIONS
" M
AX
(X)
360" INTERVAL
MAX VARIES, TYP
N O
TE
N O
T
AL
L
AC
C
ES
SA
BL
E C
O M
PO
N
EN
TS
M
AY
B E
U
SE
D
IN
T H
IS
P
R O
JE
C
T.
T
H
IS
S H
EE
T
IS
P
R O
VI
D
ED
F
O R
G
EN
ER
AL
R
EF
ER
EN
C E
O N
LY
Project No.:
Sheet No.:
M
AR
K D
AT
E
C O
M M
EN
TS
Date:
A
3000 WESTINGHOUSE DRIVE
SUITE 400
CRANBERRY TWP, PA 16066
(877) 323-6603
© Larson Design Group 2026
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
SEAL
Larson Design Group
/1 9/
9:
:0
A
M P
:\5
5\
5-
\P ar k B at hr oo m
A D
A P ro je ct \D
W G
\R ev it\
-0
5_
M o n tg om er y P a rk
_A
IS
.r vt
5835-005
G-003
M O
N
TG
O M
ER
Y
PA
R
K B
A
TH
R O
O M
A D
A
IN
TE
R
IO
R
IM
PR
O
VE
M
EN
TS
1S T
ST
, M
O N
TG
O
M
ER
Y, P
A
10-19-2026
A C
C
ES
SI
B
IL
IT
Y D
IA
G
R A
M S
IS
SU
ED
F
O R
B
ID
D
IN
G
M O
N
TG
O M
ER
Y
B O
R O
U G
H
S M
AI
N
S
TR
EE
T
M O
N
TG
O M
ER
Y, P A
0-
-2
IS
S U
E D
F O
R B
ID
D
G
TOILET ROOM FIXTURE HEIGHTS AND CLEARANCES
NOTES:
1. DIMS SHOWN ARE TO FACE OF FINISHED WALL/FLOOR/CEILING. VERIFY EXACT CLEARANCE PRIOR
TO INSTALLATION.
2. PROVIDE NON-ABSORBENT SURFACE MATERIAL UP TO 48" AND BASE UP TO 6" AFF UNO (TYP).
3. INSULATE EXPOSED WASTE AND WATER LINES BELOW LAVATORY (TYP).
4. 40" MIRROR MOUNTING HEIGHT MUST BE FROM FLOOR TO REFLECTIVE SURFACE.
5. TOILET TRIP LEVER MUST BE ON APPROACH SIDE OF FIXTURE. VERIFY PRIOR TO ORDERING.
6. GRAB BARS MUST HAVE A 250 LB WEIGHT CAPACITY.
" M
IN
30" MIN
VERIFY KNEE & TOE
CLEARANCES WITH
SPECIFIED FIXTURE
RE: MECH
NO FIXTURE
MAY OVERLAP
CLEARANCE
60" MIN
*5 9"
M
IN
* 56" AT WALL-HUNG TOILETS
URINAL CLEARANCE WATER CLOSET
CLEARANCE
WATER CLOSET
STALL CLEARANCE
" M
IN
*5
9" M
IN
60" MIN
SPACE (TYP)
6" TOE KICK
" M
IN
" M
IN
54" MIN
VERIFY KNEE & TOE
CLEARANCES WITH
SPECIFIED FIXTURE
RE: MECH
30" MIN
AMBULATORY STALL WATER CLOSET STALL
TOE CLEARANCE
LAVATORY
CLEARANCE
WATER FOUNTAINS
30"x48" CLEAR FLOOR SPACE
18" MIN24" MAX
17" - 19"
30" CLEAR
FOR SINGLE
6" MIN
15" MIN
5" MAX
9" MIN
1' -1
/2
" M
IN
HANDRAIL AND GRAB BAR MOUNTING
1 1/2" MAX
1 1/4" MIN
1 1/2"
4"-6 1/4"
PERIMETER
MAX
M
1/
2"
1 1/12" MAX
1 1/4" MIN
1 1/2"
" M
IN
1 1/2" MAX
1 1/4" MIN
1 1/2"
1 1/2"
" M
IN
1/ 2"
M
IN
HANDRAILS GRAB BARS NOTE:
NOT ALL ACCESSABLE COMPONENTS
MAY BE USED IN THIS PROJECT. THIS
SHEET IS PROVIDED FOR GENERAL
REFERENCE ONLY.
12" 42"
40" CL
CL
" M
AX
" M
IN
9" MAX
7" MIN
CL
" M
AX
" M
IN
15" 15"CL
URINALS WATER CLOSETS
18"
CL
24" 12"CL
CL
LAVATORIES
CLEARANCE
8" MIN KNEE
CLEARANCE
6" MAX TOE
" M
AX
R
EF
LE
C
TI
VE
S U
R
FA
C E
" M
AX
T
O
CL
15"
MAX
12" 24" MIN 24" MAX
EQ EQ
CL
5"
CL
ADJUSTABLE HGT HAND SHOWER W/
59" MIN LENGTH HOSE
BATHTUBS WITHOUT PERMANENT SEATS
" M
IN
MAX
12" 24" MIN 24" MAX
" M
6"
REMOVABLE SEAT
" M
IN
" M
IN
8" MAX
6" MAX
" M
AX
36"
" M
AX
" M
IN
17" MIN
9" M
IN
" M
IN
" M
IN
" M
AX
" M
AX
STAIRWAYS
STAIR HANDRAILS
PROVIDE SECOND SET OF
HANDRAILS AT 24" AFF WHEN
CHILDREN ARE PRIMARY USERS
12"
" M
AX
" M
IN
WIDTH
TREAD 12"
" M
AX
" M
IN
H
EA
D H
EI
G
H T
6' -8
" M
IN
TOP
LANDING
BOTTOM
LANDING
THE LEADING 2" (51 MM) OF THE
TREAD MUST HAVE VISUAL
CONTRAST OF DARK-ON-LIGHT OR
LIGHT-ON-DARK FROM THE
REMAINDER OF THE TREAD
(ICC/ANSI SECTION 504.5)
11" MIN
7" M
AX
4" M
IN
MAX
30°
1-1/2" MAX
1-1/2" MAX
STAIR RISERS AND TREAD
CURVED
NOSING
BEVELED
NOSING
1/2" RADIUS MAX
NOTE:
ALL HANDRAILS MUST RETURN TO POST, WALL OR FLOOR
3" MAX
PROTRUSION
4" MAX
8" MAX
4" M
AX
" M
IN
" M
AX
H
AN
D
R
AI
L
" M
IN
G
U
AR
D R
AI
L
OPEN STAIRS
SITE ELEMENTS
SEE CIVIL DRAWINGS FOR ALL SITE
RELATED ACCESSIBLE ELEMENTS
Project No.:
Sheet No.:
M
AR
K D
AT
E
C O
M M
EN
TS
Date:
A
3000 WESTINGHOUSE DRIVE
SUITE 400
CRANBERRY TWP, PA 16066
(877) 323-6603
© Larson Design Group 2026
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
SEAL
Larson Design Group
/1 9/
9:
:0
A
M P
:\5
5\
5-
\P ar k B at hr oo m
A D
A P ro je ct \D
W G
\R ev it\
-0
5_
M o n tg om er y P a rk
_A
IS
.r vt
5835-005
G-004
M O
N
TG
O M
ER
Y
PA
R
K B
A
TH
R O
O M
A D
A
IN
TE
R
IO
R
IM
PR
O
VE
M
EN
TS
1S T
ST
, M
O N
TG
O
M
ER
Y, P
A
10-19-2026
A C
C
ES
SI
B
IL
IT
Y D
IA
G
R A
M S
IS
SU
ED
F
O R
B
ID
D
IN
G
M O
N
TG
O M
ER
Y
B O
R O
U G
H
S M
AI
N
S
TR
EE
T
M O
N
TG
O M
ER
Y, P A
0-
-2
IS
S U
E D
F O
R B
ID
D
TACTILE SIGNAGE AND SYMBOLS
LETTERS AND NUMBERS:
1. LETTERS AND NUMERALS MUST BE RAISED 1/32" (0.8 MM) MINIMUM, UPPERCASE,
SANS-SERIF OR SIMPLE SERIF AND MUST BE ACCOMPANIED WITH GRADE 2 BRAILLE.
RAISED CHARACTERS MUST BE AT LEAST 5/8" (16 MM) HEIGHT, BUT NO HIGHER THAN
2" (50 MM). PICTOGRAMS MUST BE ACCOMPANIED BY THE EQUIVALENT VERBAL
DESCRIPTION PLACES DIRECTLY BELOW THE PICTOGRAM. THE BORDER
DIMENSIONS OF THE PICTOGRAM MUST BE 6" (152 MM) MINIMUM IN HEIGHT. (ADAAG
SEC. 4.30.4)
2. LETTERS AND NUMBERS ON SIGNS MUST HAVE A WIDTH-TO-HEIGHT RATIO BETWEEN
3:5 AND 1:1 AND A STROKE WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND 1:10. (ADAAG
SEC. 4.30.2)
3. THE CHARACTERS AND BACKGROUND OF SIGNS MUST BE EGGSHELL, MATTE, OR
OTHER NON-GLARE FINISH. CHARACTERS AND SYMBOLS MUST CONTRAST WITH
THEIR BACKGROUND - EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR
DARK CHARACTERS ON A LIGHT BACKGROUND. (ADAAG SEC. 4.30.5)
4. CHARACTERS AND NUMBERS ON SIGNS MUST BE SIZED ACCORDING TO THE
VIEWING DISTANCE FROM WHICH THEY ARE TO BE READ. THE MINIMUM HEIGHT IS
MEASURED USING AN UPPER CASE X. LOWER CASE CHARACTERS ARE PERMITTED.
(ADAAG SEC. 4.30.3)
5. BRAILLE MUST BE CONTRACTED (GRADE 2) BRAILLE AND MUST COMPLY WITH
SECTION 703.4. (ICC/ANSI SCE. 703.4.1)
6. BRAILLE MUST BE BELOW THE CORRESPONDING TEXT. IF TEXT IS MULTILINED,
BRAILLE MUST BE PLACED BELOW THE ENTIRE TEXT. BRAILLE MUST BE SEPARATED
3/8" (9.5 MM) MIN FROM ANY OTHER TACTILE CHARACTERS AND 3/8" (9.5 MM) MIN
FROM RAISED BORDERS AND DECORATIVE ELEMENTS. BRAILLE PROVIDED ON
ELEVATOR CAR CONTROLS MUST BE SEPARATED 3/16" (4.8 MM) MIN EITHER
DIRECTLY BELOW OR ADJACENT TO THE CORRESPONDING RAISED CHARACTERS OR
SYMBOLS. (ICC/ANSI SEC. 703.4.4)
SIGN LOCATIONS:
1. ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY PERSONS
WITH DISABILITIES AND AT EVERY MAJOR JUNCTION ALONG OR LEADING TO AN
ACCESSIBLE ROUTE OR TRAVEL MUST BE IDENTIFIED WITH A SIGN DISPLAYING THE
INTERNATIONAL SYMBOL OF ACCESSIBILITY AND WITH ADDITIONAL DIRECTIONAL
SIGNS, AS REQUIRED, TO BE VISIBLE TO PERSONS ALONG APPROACHING
PEDESTRIAN WAYS. (ICC/IBC SEC. 1110)
2. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, SIGNS
MUST BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR.
WHERE THERE IS NO WALL SPACE TO THE LATCH SIDE OF THE DOOR, INCLUDING AT
DOUBLE LEAF DOORS, SIGNS MUST BE PLACED ON THE NEAREST ADJACENT WALL.
MOUNTING HEIGHT MUST BE 60" (1525 MM) ABOVE THE FINISH FLOOR TO THE
CENTERLINE OF THE SIGN MOUNTING LOCATION FOR SUCH SIGNAGE MUST BE SO
THAT A PERSON MAY APPROACH WITHIN 3" (76 MM) OF THE SIGNAGE WITHOUT
ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A
DOOR. (ADAAG SEC. 4.30.6)
3. ADDITIONAL DIRECTIONAL SIGNS ALONG ACCESSIBLE PATH OF TRAVEL ARE
REQUIRED. (ICC/IBC SEC. 1110)
4. BUILDINGS REMODELED TO PROVIDE ACCESSIBLE SANITARY FACILITIES FOR PUBLIC
USE MUST HAVE INFORMATION POSTED IN THE LOBBY AS PART OF THE BUILDING
DIRECTORY.
INTERNATIONAL SYMBOL OF ACCESSIBILITY:
1. STANDARD USED TO IDENTIFY ACCESSIBLE FACILITIES.
2. WHITE FIGURE ON BLUE BACKGROUND, COLOR: #15090, ON FEDERAL STANDARD #
595A.
3. WHEN ENFORCING AGENCY DETERMINES, IF APPROPRIATE, SPECIAL DESIGNS AND
COLORS MAY BE APPROVED.
BRAILLE:
1. DOTS TO BE 0.09" (2.2 MM) TO 0.1" (2.5 MM) ON CENTER IN EACH CELL.
2. 0.241" (6.1 MM) TO 0.3" (7.6 MM) SPACE BETWEEN CELLS HORIZONTALLY.
3. 0.395" (10 MM) TO 0.4" (10.2 MM) SPACE BETWEEN CELLS VERTICALLY.
4. DOTS RAISED 0.025" (0.6 MM) TO 0.037" (0.9 MM) ABOVE BACKGROUND.
5. DOTS BASE DIAMETER TO BE 0.059" (1.5 MM) TO 0.063" (1.6 MM).
PROVIDE TACTILE SIGNAGE AS
PER ANSI CODE SECTION 703
EQEQ
CLEAR
18" MIN
C
LE
AR
" M
IN
EQEQ
" M
IN
" M
AX
DOOR LATCH SIDE
TACTILE SIGNAGE MOUNTING HEIGHTS
INTERNATIONAL SYMBOLS FOR ACCESSIBILITY
RAISED
1/
GENERAL RESTROOM SIGNAGE
MEN WOMEN
INTERNATIONAL
TDD SYMBOL
INTERNATIONAL
SYMBOL OF
ACCESS FOR
HEARING IMPAIRED
PROPORTIONS FOR
INTERNATIONAL
SYMBOLS FOR
ACCESSIBILITY
DOORWAYS
Z
CLEAR
32" MIN YX
REQUIRED CLEAR
SPACE PUSH SIDE
FRONT APPROACH
* 12" WITH BOTH
CLOSER AND LATCH
X= 48" MIN
Y= 0" *
LATCH APPROACH
* 48" MIN WITH BOTH
CLOSER AND LATCH
X= 42" MIN *
Y= 24" MIN
HINGE APPROACH
* 48" MIN WITH BOTH
CLOSER AND LATCH
** 12" MIN WITH BOTH
CLOSER AND LATCH
X= 42" MIN *
Y= 0" **
Z= 22" MIN
PUSH SIDE DOOR
CLEARANCE PLAN
REQUIRED CLEAR
SPACE PULL SIDE
LATCH APPROACH
* 54" MIN WITH BOTH
CLOSER AND LATCH
X= 48" MIN *
Y= 24" MIN
HINGE APPROACH
X= 60" MIN
Y= 36" MIN
X= 54" MIN
Y= 42" MIN
OR X
Y
FRONT APPROACH
X= 60" MIN
Y= 18" MIN
PULL SIDE DOOR
CLEARANCE PLAN
18" MIN INTERIOR
24" MIN EXTERIOR &
" M
IN
60" MIN
RAMP LANDING AT
DOORWAY PLAN
32" CLEAR 24" MIN EXT
18" MIN INT
60" MIN
" M
IN
VESTIBULE PLAN TWO DOORS IN SERIES
" M
IN
NOTES:
1. CLEAR SPACES MUST BE LEVEL TO PREVENT WHEELCHAIRS FROM
ROLLING WHEN THE OCCUPANT RELEASES THE WHEEL GRIPS TO REACH
FOR THE DOOR. 1/4" PER FOOT IS ALLOWED FOR DRAINAGE.
2. WHERE DOORS OPEN ONTO, BUT NOT INTO, A CORRIDOR THE REQUIRED
LEVEL AREA BEYOND THE DOORS MAY BE A MINIMUM OF 48"
RESTROOMS
N O
TE
N O
T
AL
L
AC
C
ES
SA
BL
E C
O M
PO
N
EN
TS
M
AY
B E
U
SE
D
IN
T H
IS
P
R O
JE
C
T.
T
H
IS
S H
EE
T
IS
P
R O
VI
D
ED
F
O R
G
EN
ER
AL
R
EF
ER
EN
C E
O N
LY
Project No.:
Sheet No.:
M
AR
K D
AT
E
C O
M M
EN
TS
Date:
A
3000 WESTINGHOUSE DRIVE
SUITE 400
CRANBERRY TWP, PA 16066
(877) 323-6603
© Larson Design Group 2026
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
SEAL
Larson Design Group
/1 9/
9:
:0
A
M P
:\5
5\
5-
\P ar k B at hr oo m
A D
A P ro je ct \D
W G
\R ev it\
-0
5_
M o n tg om er y P a rk
_A
IS
.r vt
5835-005
G-005
M O
N
TG
O M
ER
Y
PA
R
K B
A
TH
R O
O M
A D
A
IN
TE
R
IO
R
IM
PR
O
VE
M
EN
TS
1S T
ST
, M
O N
TG
O
M
ER
Y, P
A
10-19-2026
A C
C
ES
SI
B
IL
IT
Y D
IA
G
R A
M S
IS
SU
ED
F
O R
B
ID
D
IN
G
M O
N
TG
O M
ER
Y
B O
R O
U G
H
S M
AI
N
S
TR
EE
T
M O
N
TG
O M
ER
Y, P A
0-
-2
IS
S U
E D
F O
R B
ID
D
CONCRETE BLOCK
SECTIONS/ SECTIONAL DETAILS
CAST-IN-PLACE-CONCRETE
STRUCTURAL/MISCELLANEOUS
STEEL
EARTH
GRAVEL/ENGINEERED
FILL
STONE, OR NATURAL
BUILDING STONE
PLASTER OR GYPSUM BOARD,
OR EXTERIOR SHEATHING
BATT INSULATION
ROOF, TAPERED, CAVITY OR
RIGID INSULATION
FINISHED WOOD TRIM
PLYWOOD
CAVITY DRAINAGE MATERIAL
N
PLAN
NORTH
1i
Room name
X
1A2.2
W1
NORTH ARROW
SECTION
MARKER
ELEVATION
STAIR TAG
ROOM TAG
KEY TAG(s)
WALL TYPE
WINDOW TYPE
VIEW NAME,
NUMBER AND
SCALE
STAIR TAG
DOOR NUMBER
EXTERIOR ELEVATION
INTERIOR ELEVATION
0 GRID LOCATION
REVISION TAG
A101
SIM
A101
A101
XX
SYMBOLS
KEY NOTE TAGXX.XX
PLANS / PLAN DETAIL GRAPHICS
CONCRETE BLOCK WALLS
CAST-IN-PLACE-
CONCRETE WALLS
STUD WALLS
BRICK WALLS
CONCRETE SLABS AND/OR
CONCRETE SIDEWALKS
EXISTING WALLS
DOOR DESIGNATIONS
EXISTING DOOR AND/OR FRAME TO
REMAIN - SEE DOOR SCHEDULE FOR ANY
ADDITIONAL WORK
NEW DOOR AND/OR FRAME TO BE
PROVIDED - SEE DOOR SCHEDULE
GENERAL NOTES
1. CONTRACTORS MUST NOT SCALE THESE DRAWINGS
FOR CONSTRUCTION PURPOSES. IN THE EVENT OF
OMISSION OF NECESSARY DIMENSIONS OR
INFORMATION, CONTRACTOR MUST NOTIFY
ARCHITECT/ENGINEER. DETAILED DRAWINGS AND
LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER
SMALLER SCALE DRAWINGS.
2. CONTRACTOR SHALL VERIFY ALL COLUMN
COORDINATES AND CHECK THEM AGAINST DIMENSIONS
SHOWN ON PLANS AND DETAILS. NOTIFY ARCHITECT OF
ANY DISCREPANCY DURING STAKING.
3. ALL FINISHED FLOOR ELEVATIONS RE: TO
ARCHITECTURAL DRAWINGS ONLY. RE: CIVIL DRAWINGS
FOR RELATIONSHIP TO PROJECT BENCHMARK(S).
4. VERIFY ALL DIMENSIONS, CONDITIONS, AND GRADES AT
JOB SITE. ALL CONTRACTORS MUST COORDINATE THEIR
WORK WITH OTHER TRADES AND REPORT
DISCREPANCIES, PRIOR TO THEIR CONSTRUCTION, TO
THE ARCHITECT FOR REVIEW AND CLARIFICATION OR
ACTION.
5. VERIFY SIZE, LOCATIONS CHARACTERISTICS AND
INSTALLATION REQUIREMENTS OF ALL EQUIPMENT TO
BE FURNISHED WITH MANUFACTURERS OR SUPPLIERS
BEFORE BEGINNING CONSTRUCTION.
6. VERIFY SIZE AND LOCATION OF ALL OPENINGS FOR
MECHANICAL AND ELECTRICAL EQUIPMENT AND
RELATED WORK WITH CONTRACTORS INVOLVED AND
EQUIPMENT TO BE FURNISHED. FOR CONSTRUCTION
DETAILS NOT SHOWN, USE THE MANUFACTURER'S
STANDARD DETAILS OR APPROVED SHOP DRAWINGS /
DATA SHEETS IN ACCORDANCE WITH THE PROJECT
SPECIFICATIONS.
7. VERIFY ALL ELEVATIONS AND DIMENSIONS OF
STRUCTURAL ELEMENTS WITH ARCHITECTURAL
DRAWINGS. IN CASE OF CONFLICT, NOTIFY
ARCHITECT/ENGINEER. THE CONTRACTORS MUST
VERIFY ALL DIMENSIONS AND BE RESPONSIBLE FOR
THEM. ALL DIMENSIONAL DISCREPANCIES ARE TO BE
BROUGHT TO THE ATTENTION OF THE
ARCHITECT/ENGINEER.
8. ADD SUFFICIENT BLOCKING IN STUD WALLS TO
SUPPORT ALL ITEMS OR EQUIPMENT SHOWN OR
SPECIFIED TO BE ATTACHED TO THE WALLS. PROVIDE
ADDITIONAL STRUCTURAL SUPPORT (ANGLES,
CHANNELS, ETC.) WITHIN WALLS WHERE THE WEIGHT OF
ATTACHED ITEMS OR EQUIPMENT IS TOO GREAT TO BE
SUPPORTED BY METAL STUDS. PROVIDE BLOCKING FOR
OWNER FURNISHED AND/ OR INSTALLED ITEMS, IF ANY.
9. ALL INTERIOR DIMENSIONS TO FACE OF STUD, FACE OF
MASONRY, CENTERLINE OF COLUMN, OR EDGE OF SLAB
UNLESS NOTED OTHERWISE.
10. ALL MATERIALS ARE TO BE INSTALLED IN ACCORDANCE
WITH MANUFACTURER BEST PRACTICE
RECOMMENDATIONS UNLESS NOTED OTHERWISE.
11. THE ARCHITECTURAL FLOOR PLANS, REFLECTED
CEILING PLANS, SECTIONS, AND ELEVATIONS SHOW THE
EXACT LOCATION OF MANY, BUT NOT ALL, EXPOSED
PARTS OF THE WORK. FOR TYPICAL DIMENSIONING
CONVENTIONS, INCLUDING RULES FOR LOCATING
DOORS AND OTHER ITEMS WHICH HAVE NOT BEEN
DIMENSIONED OR LOCATED EXACTLY, APPLY THE RULES
INDICATED BY THE "GENERAL CONVENTIONS" SHEET TO
DETERMINE THE EXACT LOCATION OF EACH EXPOSED
PART OF THE WORK.
12. 3/4" FIRE-RETARDANT TREATED PLYWOOD BACKING 8'-0"
HIGH SHALL BE PROVIDED AND INSTALLED ON ALL
WALLS OF TELEPHONE AND ELECTRICAL ROOMS AS
REQUIRED UNLESS SPECIFICALLY SHOWN OTHERWISE
ON ELECTRICAL DRAWINGS.
13. PROVIDE AND INSTALL ACCESS PANELS, WHERE
REQUIRED BY BUILDING CODE OR FOR THE PROPER
OPERATION OF MECHANICAL OR ELECTRICAL
EQUIPMENT, AND AS SHOWN ON THE DRAWINGS.
CONTRACTOR SHALL COORDINATE SIZE, LOCATION, AND
TYPE OF ACCESS PANEL WITH OTHER CONTRACTORS'
WORK AND RECEIVE APPROVAL OF THE ARCHITECT.
ACCESS PANEL SHALL BE AS SPECIFIED.
14. ALL METAL STUDS WALLS WHERE PLUMBING OCCURS
OR STRUCTURAL COLUMNS ARE LOCATED WITH SHALL
BE MINIMUM 6" METAL STUDS. NOTIFY ARCHITECT OF
ANY DISCREPANCIES OR CONFLICTS.
15. SIZES OF HOUSEKEEPING PADS AND BASES FOR
MECHANICAL EQUIPMENT ARE APPROXIMATE.
CONTRACTOR SHALL VERIFY EXACT LOCATION AND
REQUIRED SIZE OF ALL CONCRETE PADS AND BASES
WITH EQUIPMENT MANUFACTURERS BEFORE POURING.
ALL PADS TO BE PROVIDED BY THE CONTRACTOR.
DEMOLITION LEGEND
EXISTING WINDOW AND/OR FRAME TO BE
REMOVED - SEE DEMO PLAN/NOTES
EXISTING DOOR AND/OR FRAME TO BE
REMOVED - SEE DEMO PLAN/NOTES
EXISTING WALL TO BE REMOVED - SEE
DEMO PLAN/NOTES
Project No.:
Sheet No.:
M
AR
K D
AT
E
C O
M M
EN
TS
Date:
A
3000 WESTINGHOUSE DRIVE
SUITE 400
CRANBERRY TWP, PA 16066
(877) 323-6603
© Larson Design Group 2026
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
SEAL
Larson Design Group
/1 9/
9:
:0
A
M P
:\5
5\
5-
\P ar k B at hr oo m
A D
A P ro je ct \D
W G
\R ev it\
-0
5_
M o n tg om er y P a rk
_A
IS
.r vt
5835-005
A-001
M O
N
TG
O M
ER
Y
PA
R
K B
A
TH
R O
O M
A D
A
IN
TE
R
IO
R
IM
PR
O
VE
M
EN
TS
1S T
ST
, M
O N
TG
O
M
ER
Y, P
A
10-19-2026
G
EN
ER
A
L N
O
TE
S, S
YM
B
O
LS
IS
SU
ED
F
O R
B
ID
D
IN
G
M O
N
TG
O M
ER
Y
B O
R O
U G
H
S M
AI
N
S
TR
EE
T
M O
N
TG
O M
ER
Y, P A
12" = 1'-0"
NAME
0-
-2
IS
S U
E D
F O
R B
ID
D
DEMOLISH AND REMOVE EXISTING CMU
PARTITION WALLS AND STALL DOORS,
INCLUDING ALL ASSOCIATED
COMPONENTS (TYP.).
EXISTING WINDOWS
TO BE REMOVED AND REPLACED (TYP.).
REMOVE EXISTING DOOR AND
FRAME. SAVE FOR REINSTALL
REMOVE EXISTING DOOR AND
FRAME. SAVE FOR REINSTALL
PLAN NOTES - DEMOLITION PLAN
A. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE
MANNER AND IN STRICT ACCORDANCE WITH OSHA
REGULATIONS.
B. THE CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF
DEMOLITION. THE WORK INCLUDES, BUT IS NOT LIMITED
TO, THE DEMOLITION AND REMOVAL OF WALLS, DOORS,
PLUMBING, PAVING, MECHANICAL AND ELECTRICAL
ITEMS INCLUDING CONDUITS AND DUCTWORK AS
SHOWN ON DRAWINGS OR AS REQUIRED FOR THE
INSTALLATION OF THE NEW WORK FOR A COMPLETE
JOB.
C. WHEN UTILITIES ARE REMOVED, CAP AND SEAL A
MINIMUM OF 8" BELOW FINISH FLOOR OR BACK TO
PRIMARY RUNS WHEN ABOVE SLAB. ALL UNUSED
SUPPORTS, HANGERS, AND ACCESSORIES ARE TO BE
REMOVED.
D. WHEN REMOVING EXISTING STRUCTURAL ITEMS, IT IS
THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE
ADEQUATE SHORING, BRACING, AND SUPPORT SYSTEMS
TO KEEP THE EXISTING STRUCTURE INTACT AND IN
SAFE CONDITION.
E. NOTES INDICATING DEMOLITION WORK ARE NOT
CONFINED SOLELY TO THE DEMOLITION PLANS. THE
GENERAL CONTRACTOR SHALL REVIEW ALL
CONSTRUCTION DOCUMENTS, INCLUSIVE OF
SCHEDULES AND SPECIFICATIONS, TO DETERMINE FULL
EXTENT OF DEMOLITION SCOPE OF WORK.
F. CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL
EXISTING BUILDING MATERIALS TO REMAIN AT ALL
TIMES.
G. PREP AND PATCH AREAS OF DEMOLITION TO RECEIVE
NEW CONSTRUCTION OR COATINGS.
H. REFER TO MEP SHEETS FOR ADDITIONAL DEMOLITION
INFORMATION NOT SHOWN.
I. STORE AND PROTECT ALL EXISTING HAND HELD
EXTINGUISHERS, INVENTORIED AND REPORTED TO
OWNER. AT OWNER'S OPTION THE CONTRACTOR IS TO
EITHER TURN OVER THE EXISTING EXTINGUISHER FOR
OWNER'S USE OR DISPOSE OF THEM AS PART OF THE
DEMOLITION SCOPE.
J. AT ALL LOCATIONS OF SURFACE MOUNTED ELECTRICAL
ITEMS, CONTRACTOR IS TO REMOVE AND DISPOSE OF
ALL J-BOXES, BACK BOXES, CONDUITS, STRAPS,
HANGERS, AND ALL ASSOCIATED ITEMS.
K. REFER TO FLOOR PLANS, EXTERIOR ELEVATIONS, AND
SITE PLAN FOR ADDITIONAL INFORMATION OF ITEMS
THAT MAY BE LOCATED ON OPPOSITE SIDE OF WALLS
TO BE DEMOLISHED. CONTRACTOR TO EXERCISE
CAUTION AND AWARENESS AT ALL TIMES OF
DEMOLITION SCOPE.
L. CONTRACTOR TO ENSURE EXISTING PARK BUILDING
ATTACHED TO THE BATHROOMS REMAINS FUNCTIONAL
DURING CONSTRUCTION.
M. AN ATTEMPT HAS BEEN MADE TO SHOW ON THE
DRAWINGS EXISTING BUILDING CONSTRUCTION AND
CONDITIONS, HOWEVER, THE CONTRACTOR SHALL BE
RESPONSIBLE FOR INSPECTING AND VERIFYING ALL
EXISTING CONDITIONS PRIOR TO THE START OF
CONSTRUCTION, AND SHALL REPORT ANY
DISCREPANCIES TO THE ENGINEER FOR CLARIFICATION
BEFORE PROCEEDING WITH THE WORK.
N. ANY DEMOLITION IN ADDITION TO WHAT IS REFERENCED
ON THE DRAWINGS SHALL BE APPROVED BY ARCHITECT
PRIOR TO BEGINNING. ANY ADDITIONAL DEMOLITION
REQUIRED AS A CONVENIENCE TO THE CONTRACTOR
SHALL BE AT THE CONTRACTOR’S EXPENSE AND SHALL
BE REPLACED AT THE CONTRACTOR’S EXPENSE.
N
Project No.:
Sheet No.:
M
AR
K D
AT
E
C O
M M
EN
TS
Date:
A
3000 WESTINGHOUSE DRIVE
SUITE 400
CRANBERRY TWP, PA 16066
(877) 323-6603
© Larson Design Group 2026
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
SEAL
Larson Design Group
/1 9/
9:
:0
A
M P
:\5
5\
5-
\P ar k B at hr oo m
A D
A P ro je ct \D
W G
\R ev it\
-0
5_
M o n tg om er y P a rk
_A
IS
.r vt
5835-005
AD101
M O
N
TG
O M
ER
Y
PA
R
K B
A
TH
R O
O M
A D
A
IN
TE
R
IO
R
IM
PR
O
VE
M
EN
TS
1S T
ST
, M
O N
TG
O
M
ER
Y, P
A
10-19-2026
A R
C H
IT
EC
TU
R
A L
D
EM
O
LI
TI
O
N P
LA
N
IS
SU
ED
F
O R
B
ID
D
IN
G
M O
N
TG
O M
ER
Y
B O
R O
U G
H
S M
AI
N
S
TR
EE
T
M O
N
TG
O M
ER
Y, P A
3/4" = 1'-0"A1 ARCHITECTURAL - RESTROOM DEMOLITION PLAN
SCALE:
1' - 0" 2' - 0" 4' - 0"
3/4" = 1' - 0"
0-
-2
IS
S U
E D
F O
R B
ID
D
NEW 24" X 36" FIXED VINYL WINDOW WITH
WINDOW PROTECTION ON INTERIOR AND
EXTERIOR (TYP.).
REFER TO DIVISION 08 - OPENINGS.
REFERENCE PLUMBING
DRAWINGS FOR
MOUNTING HEIGHTS
RELOCATED DOOR
AND FRAME.
RELOCATED DOOR
AND FRAME.
PLAN NOTES - FLOOR PLAN
1. ALL DIMENSIONS ON PLAN FOR NEW INTERIOR WALL
LAYOUTS ARE FROM FACE OF STUD, FACE OF MASONRY,
CENTERLINE OF COLUMN OR EDGE OF SLAB, U.N.O..
2. PATCH & FIRESTOP GYP. BD. PARTITIONS AS REQUIRED
BY LOCAL CODES.
3. APPROVED FIRE EXTINGUISHERS MUST BE FURNISHED
AND INSTALLED BY G.C. AS REQUIRED BY LOCAL
AUTHORITY.
4. PROVIDE & INSTALL BROWN PAPER COVERING APPLIED
TO THE STOREFRONT GLAZING DURING FURNISHING.
5. ALL INTERIOR ARTITIONS MUST EXTEND MIN. 6" ABOVE
FINISHED CEILING UNLESS NOTED OTHERWISE.
6. REFER TO BUILDING AND WALL SECTIONS FOR ALL
EXTERIOR WALL CONSTRUCTION.
7. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT
SHOWN WITH THE ARCHITECT PRIOR TO INSTALLATION.
8. DISCONTINUE ALL DRYWALL ON INTERIOR FACE OF
EXTERIOR WALL AT ALL INTERSECTING WALLS, TYP.
9. 3/4" FIRE-RETARDANT TREATED PLYWOOD BACKING 8'-0"
HIGH SHALL BE PROVIDED AND INSTALLED ON ALL
WALLS OF TELEPHONE AND ELECTRICAL ROOMS AS
REQUIRED UNLESS SPECIFICALLY SHOWN OTHERWISE
ON ELECTRICAL DRAWINGS.
3/4" = 1'-0"A1 ARCHITECTURAL - RESTROOM PLAN
N
Project No.:
Sheet No.:
M
AR
K D
AT
E
C O
M M
EN
TS
Date:
A
3000 WESTINGHOUSE DRIVE
SUITE 400
CRANBERRY TWP, PA 16066
(877) 323-6603
© Larson Design Group 2026
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
SEAL
Larson Design Group
/1 9/
9:
:0
A
M P
:\5
5\
5-
\P ar k B at hr oo m
A D
A P ro je ct \D
W G
\R ev it\
-0
5_
M o n tg om er y P a rk
_A
IS
.r vt
5835-005
A-101
M O
N
TG
O M
ER
Y
PA
R
K B
A
TH
R O
O M
A D
A
IN
TE
R
IO
R
IM
PR
O
VE
M
EN
TS
1S T
ST
, M
O N
TG
O
M
ER
Y, P
A
10-19-2026
A R
C H
IT
EC
TU
R
A L
FL
O
O R
P
LA
N
IS
SU
ED
F
O R
B
ID
D
IN
G
M O
N
TG
O M
ER
Y
B O
R O
U G
H
S M
AI
N
S
TR
EE
T
M O
N
TG
O M
ER
Y, P A
KEY NOTES
1. AREA OF PARTIALLY REMOVED WALL BACKING WITH
EXPOSED FRAMING. PATCH AND RESTORE WALL WITH
MOSITURE-RESISTANT GYPSUM BOARD AND FINISHES
TO MATCH ADJACENT SURFACES.
2. CONTRACTOR SHALL PREPARE ALL EXISTING WALLS,
CEILINGS, AND CONDUIT TO RECEIVE NEW FINISHES.
PREPARATION SHALL INCLUDE CLEANING, PATCHING,
REPAIRING OF CRACKS AND DEFECTS AND REMOVAL
OF DETERIORATED MATERIALS. PROVIDE PRIMER AND
FINISH COATS IN ACCORDANCE WITH SPECIFICATIONS,
REFER TO DIVISION 09 - PAINTINGS/COATINGS. ALL
PAINTED SURFACES SHALL RECEIVE A UNIFORM,
SINGLE COLOR AS SELECTED BY OWNER.
3. CONTRACTOR SHALL PREPARE EXISTING FLOORS TO
RECEIVE NEW EXPOXY, NON-SLIP FLOOR COATING
SYSTEM. PREPARATION SHALL INCLUDE CLEANING,
REPAIRING OF CRACKS AND SPALLS, AND REMOVAL OF
DETERIORATED MATERIALS. APPLY EPOXY COATING
SYSTEM IN ACCORDANCE WITH MANUFACTURERS
RECOMMENDATIONS, REFER TO DIVISION 09 -
PAINTINGS/COATINGS.
4. PROVIDE NEW 24" X 18" LOUVER IN EXTERIOR DOOR.
5. PROVIDE NEW 14" 'WHIRLYBIRD' INTERNALLY BRACED
ALUMINUM WIND TURBINE. CUT NEW TURBINE INTO
EXISTING ROOFING TO REMAIN AND PROVIDE NEW
FLASHING/STORM COLLAR WITH LOWER HALF OF
FLASHING EXTENDING OVER THE EXISTING ROOFING
AND UPPER HALF OF FLASHING EXTENDING UNDER THE
EXISTING ROOFING. PROVIDE ADDITIONAL
BLOCKING/BRACING AT EXISTING ROOF STRUCTURE AS
REQUIRED FOR PROPER INSTALLATION OF NEW
TURBINE.
SCALE:
1' - 0" 2' - 0" 4' - 0"
3/4" = 1' - 0"
0-
-2
IS
S U
E D
F O
R B
ID
D
OS
DL
LC
J
J
F1
DO
M
OS
TC
J
FB
PC
SPD
ELECTRICAL DEVICE TAGS: UPPERCASE LETTER(S) INDICATES
PANEL ID AND CIRCUIT NUMBER. LOWERCASE LETTER INDICATES
DESIGNATION OF CONTROLLING SWITCH (WHERE APPLICABLE).
SWITCH ID INDICATED BY A LOWERCASE LETTER. SWITCH IDS ARE UNIQUE PER
SPACE. A SWITCH WITH AN ID "A" CONTROLS ALL DEVICES WITHIN THE SPACE IN
WHICH IT IS LOCATED TAGGED WITH "A". A SWITCH WITHOUT A TAGGED ID
CONTROLS ALL LIGHTING FIXTURES WITHIN A SPACE. ID TAGS MAY BE USED ON
CONTROL DEVICES OTHER THAN SWITCHES, SUCH AS OCCUPANCY SENSORS
OR CONTACTORS.
EQUIPMENT TAGS: EQUIPMENT ID IS INDICATED BY AN UNDERLINED
TAG ADJACENT TO THE EQUIPMENT. SEE THE EQUIPMENT
CONNECTION SCHEDULE FOR DESCRIPTION, ELECTRICAL
REQUIREMENTS, AND PANEL AND CIRCUIT NUMBER.
SYMBOLS/GRAPHIC APPEARANCE OF EQUIPMENT VARIES.
SOLID, ARCED LINES CONNECTING EQUIPMENT, DEVICES, OR FIXTURES
INDICATE UNSWITCHED POWER CIRCUITING. WIRES ARE ONLY
INTENDED TO INDICATE TO WHAT CIRCUIT DEVICES ARE CONNECTED.
ACTUAL CONNECTIONS, CIRCUIT ROUTING, INSTALLTION, JUNCTION
BOXES, ETC. SHALL BE FIELD-DETERMINED BY THE CONTRACTOR.
HOME RUN TO BRANCH CIRCUIT PANELBOARD. THE EQUIPMENT
NAME AND CIRCUIT NUMBER(S) ARE INDICATED, SEPARATED BY A
HYPHEN. HOMERUNS ARE ONLY INTENDED TO INDICATE PANEL
AND CIRCUIT NUMBER. ACTUAL HOMERUN LOCATION SHALL BE
FIELD-DETERMINED BY THE CONTRACTOR.
POWER SYMBOLS
ELECTRICAL SYMBOL LEGEND
ROOM
EXIT LIGHT, WALL-MOUNTED. SHADING AND ARROWS INDICATE FACES
AND DIRECTIONAL CHEVRONS.
WALL-MOUNTED FIXTURES, TYPICAL (VARIOUS SYMBOLS)
EMERGENCY LIGHTING UNIT, WALL-MOUNTED, REMOTE BATTERY
EMERGENCY LIGHTING UNIT, WALL-MOUNTED, INTEGRAL BATTERY
EMERGENCY LIGHTING UNIT, CEILING-MOUNTED, INTEGRAL BATTERY
EMERGENCY LIGHTING UNIT, CEILING-MOUNTED, REMOTE BATTERY
LIGHTING FIXTURES, TYPICAL, RECTANGULAR(VARIOUS SYMBOLS)
OUTER DOTS INDICATE SUSPENDED.
LIGHTING FIXTURES, TYPICAL, ROUND (VARIOUS SYMBOLS)
CENTER DOT INDICATES PENDANT.
DIAGONAL LINE INDICATES DOWNLIGHT.
CHEVRON INDICATES WALL WASH.
DIRECTIONAL LIGHT, TRACK LIGHT, FLOOD LIGHT
EXIT LIGHT, CEILING-MOUNTED. SHADING AND ARROWS INDICATE
FACES AND DIRECTIONAL CHEVRONS.
LINEAR LIGHT
EXIT LIGHT/EMERGENCY LIGHTING UNIT COMBO
DIAGONAL HATCH INDICATES LIGHT ON A CRITICAL CIRCUIT.
DIAGONAL HATCH INDICATES LIGHT ON AN EMERGENCY OR LIFE SAFETY
CIRCUIT.
EXTERIOR AREA LIGHT AND POLE.
EXTERIOR POST-TOP AREA LIGHT AND POLE.
BOLLARD LIGHT
SINGLE- SWITCH
FOUR-WAY SWITCH
SWITCH MODIFIERS:
K: KEYED
D: DIMMING
T: TIMER
P: PILOT
OS: OCCUPANCY SENSOR
OSD: OCCUPANCY SENSOR DIMMER
VS: VACANCY SENSOR
AC: ABOVE-COUNTER
LV: LOW-VOLTAGE
LIGHTING CONTACTOR
LIGHTING CONTROL STATION
OCCUPANCY SENSOR
DAYLIGHT HARVESTING SENSOR
SIMPLEX RECEPTACLE
DUPLEX RECEPTACLE
QUADRUPLEX RECEPTACLE
SPECIAL RECEPTACLE, TYPE AS INDICATED
W
AL
L C
EI
LI
N G
FL
O
O
R RECEPTACLE MODIFIERS:
##": HEIGHT AFF ON CENTER
AC: ABOVE COUNTER
GFCI: GROUND-FAULT CIRCUIT INTERRUPTER
WP: WEATHERPROOF IN-USE COVER
TR: TAMPER RESISTANT
HALF SHADING INDICATES SPLIT (TYPICALLY SWITCHED)
OUTSIDE SHADING INDICATES EMERGENCY CIRCUIT
CENTER SHADING INDICATES ISOLATED GROUND
CORD REEL, DEVICE VARIES
DROP CORD, DEVICE VARIES
JUNCTION BOX
FLOOR BOX
EMERGENCY POWER OFF
DOOR OPENER PUSH PLATE
POWER METER
SAFETY SWITCH, FUSED
SAFETY SWITCH, UNFUSED
MOTOR STARTER
COMBINATION STARTER/DISCONNECT
GROUND ROD
GROUND ROD WITH TEST WELL
LIGHTNING PROTECTION AIR TERMINAL
LIGHTNING PROTECTION CONDUCTOR SPLICE
STATIC GROUND RECEPTACLE
LIGHTING SYMBOLS
CONTACTOR
TOGGLE SWITCH
SWITCH MODIFIERS:
M: MOTOR-RATED
MS: MANUAL MOTOR STARTER
GROUNDING AND LIGHTNING PROTECTION SYMBOLS
a EQUIPMENT IS TAGGED WITH PANEL NAME AND WITH PANEL ID IN PARENTHESES.
PANEL ID IS INTENDED AS A DESIGN DOCUMENTATION AID ONLY. DO NOT
INCLUDE PANEL ID IN FIELD-APPLIED CIRCUIT DIRECTORIES OR LABELS.
HATCHED FILL INDICATES DISTRIBUTION PANEL OR SWITCHBOARD.
SOLID FILL INDICATES BRANCH PANEL OR LOAD CENTER.
DASHED BOX INDICATES CODE-REQUIRED CLEARANCE (WIDTH AND DEPTH).
DOOR INDICATES FRONT OF RECESSED PANEL.
PANELBOARDS ARE ASSIGNED AN ABBREVIATED INDICATOR (OR PANEL ID)
FOR USE WITH CIRCUIT NUMBERS. PANEL ID IS LISTED WITHIN THE PANEL
SCHEDULE AND IN THE PANEL ABBREVIATION SCHEDULE.
POWER DISTRIBUTION EQUIPMENT
H P1
A( B)
LP
1A
(C
M D
P( A)
SB1(S)
DEVICES AND FIXTURES ARE TAGGED WITH PANEL ID AND CIRCUIT NUMBER.
FOR EXAMPLE, A DEVICE TAGGED WITH "A1" INDICATES THE DEVICE IS
CIRCUITED TO PANEL DESIGNATED "A," CIRCUIT NUMBER 1. THE PANEL
SCHEDULE CIRCUIT NUMBER CONTANS BOTH THE PANEL ABBREVIATION AND
THE CIRCUIT NUMBER.
XX-1
TRANSFORMER: SEE SINGLE-LINE DIAGRAM FOR DESCRIPTION AND
REQUIREMENTS.
DASHED, ARCED LINES CONNECTING EQUIPMENT, DEVICES, OR
FIXTURES INDICATE SWITCHED POWER.
ABSENCE OF A SWITCH DESIGNATION ON A LIGHTING FIXTURE INDICATES
FIXTURE IS CONTROLLED BY THE ONLY SWITCH IN THE SPACE. AN "X" IN
PLACE OF THE SWITCH DESIGNATION INDICATES UNSWITCHED.
LOWERCASE LETTER: SWITCH ID
LIGHTING TAGS
TOP VALUE: FIXTURE TYPE
ID (UNDERLINED)
BOTTOM VALUE, NUMBER(S): CIRCUIT NUMBER
a a
C1a
WIRING
POWER DEVICE AND EQUIPMENT TAGS
CONSTRUCTION PHASING
EXISTING TO BE DEMOLISHED
NEW
(TYPICAL ALL SYMBOLS AND EQUIPMENT)
ROOM NAME / NUMBER
KEYNOTE SYMBOL
CONTINUATION SYMBOL
SHEET NUMBER WHERE DETAIL IS PLACED
DETAIL NUMBER ON SHEET
REVISION
GENERAL PLAN SYMBOLS
AREA NOT IN CONTRACT
SHEET NUMBER WHERE SECTION IS PLACED
SECTION NUMBER ON SHEET
CONSTRUCTION NOTE SYMBOL##
DEMOLITION NOTE SYMBOL##
EXISTING
* NOTE *
ALL GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS IN
THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT
BE USED IN THIS SET OF DRAWINGS.
A,A1a A
AREA BEING DEMOLISHED
TIME CLOCK
JUNCTION BOX
MULTI OUTLET FLOOR BOX
PHOTOCELL
SURGE PROTECTION DEVICE
GROUND BAR
XX.XX
ELECTRICAL GENERAL NOTES
1. THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO INSTALL ALL NEW WIRING
CONCEALED (FISHED THRU OPENINGS IN EXISTING BUILDING CONSTRUCTION) IN FINISH
AREAS OF THE BUILDING CONSTRUCTION. THE USE OF EXPOSED SURFACE RACEWAYS
WILL NOT BE PERMITTED UNLESS NOTED OTHERWISE. WHERE BUILDING
CONSTRUCTION MUST BE CUT TO CONCEAL NEW CONDUIT AND WIRING THE
CONTRACTOR SHALL SAW CUT A CHANNEL IN BUILDING CONSTRUCTION, INSTALL NEW
CONDUIT AND PATCH AND FINISH DISTURBED AREAS TO MATCH ADJACENT SURFACES
AS APPROVED BY THE ARCHITECT.
2. ALL ELECTRICAL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST
NATIONAL ELECTRICAL CODE AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL
CODES.
3. ALL ELECTRICAL WORK, WIRING, CONNECTIONS AND ASSOCIATED EQUIPMENT WITHIN
THE AREA OF WORK SHALL BE AS PER APPLICABLE ARTICLES OF THE NATIONAL
ELECTRICAL CODE. COORDINATE WITH SPECIFICATIONS FOR DEVICE REQUIREMENTS.
4. ALL ELECTRICAL WORK, ELECTRICAL CONTRACTOR RESPONSIBLE TO ARRANGE
INSPECTION OF ELECTRICAL EQUIPMENT, INCLUDING CONDUCTOR TERMINATIONS IN
PANELS, IN A DE-ENERGIZED CONDITION.
5. ELECTRICAL CONTRACTOR RESPONSIBLE TO REVIEW/REPLACE ALL ELECTRICAL WORK
IN SCOPE TO MEET THE CURRENT NEC CODE REQUIREMENTS.
6. FOR SINGLE PHASE CIRCUITS, UNLESS NOTED OTHERWISE, NEW WIRING INDICATED
SHALL BE 2#12,#12GRD IN 3/4" CONDUIT. FOR THREE PHASE CIRCUITS, UNLESS NOTED
OTHERWISE, NEW WIRING INDICATED SHALL BE 3#12,#12GRD IN 3/4" CONDUIT. FOR
CIRCUITS THAT REQUIRE LONG TRAVEL DISTANCES, REFER TO VOLTAGE DROP NOTE
BELOW, ON THIS SHEET.
7. FURNISH AND INSTALL ALL WIRE, CONDUIT, CONNECTORS, OUTLETS BOXES, ETC.
NECESSARY TO ACHIEVE A COMPLETE ELECTRICAL INSTALLATION. WHERE AN
ELECTRICAL DEVICE IS REQUIRED BY CODE BUT NOT SHOWN SHALL BE FURNISHED
AND INSTALLED AS THOUGH FULLY SHOWN AND SPECIFIED.
8. ALL CONDUIT, JUNCTION BOXES, ETC. ABOVE CEILINGS SHALL BE SUPPORTED FROM
THE BUILDING'S STRUCTURAL SYSTEM. LIGHT FIXTURES WHICH ARE INSTALLED IN A
SUSPENDED CEILING SYSTEM MUST ALSO BE MECHANICALLY FASTENED TO THE
BUILDING'S STRUCTURAL SYSTEM.
9. NO CUTTING OF BUILDING CONSTRUCTION SHALL BE DONE WHICH MAY IN ANYWAY
AFFECT THE BUILDING STRUCTURALLY OR ARCHITECTURALLY WITHOUT FIRST
SECURING THE ENGINEER'S CONSENT AND APPROVAL.
10. NO CONDUITS SHALL BE RUN THROUGH OR SUPPORTED FROM DUCTWORK.
11. ALL EXISTING AREAS WHICH ARE DAMAGED BECAUSE OF THE ELECTRICAL WORK
UNDER THIS CONTRACT SHALL BE REPAIRED AND/OR REFINISHED. THE CONTRACTOR
WILL BE RESPONSIBLE FOR ALL CUTTING, PATCHING, PAINTING AND
REMOVING/REPLACING CEILING TILES DAMAGED OR SOILED AS IS NECESSARY.THE
ENTIRE INSTALLATION MUST BE GROUNDED IN COMPLIANCE WITH THE NATIONAL
ELECTRICAL CODE. ALL DEVICES, EQUIPMENT BOXES, ETC. MUST BE CONNECTED TO A
SOLID, INSULATED GREEN, COPPER GROUNDING CONDUCTOR. THIS GROUNDING
CONDUCTOR MUST BE CONTINUOUS WITHOUT SPLICES FROM POINT OF ORIGIN IN
PANELBOARD TO ALL BOXES AND EQUIPMENT ON EACH BRANCH CIRCUIT. VERIFY
GROUNDING VALUES.
12. THE ENTIRE INSTALLATION MUST BE GROUNDED IN COMPLIANCE WITH THE NATIONAL
ELECTRICAL CODE. ALL DEVICES, EQUIPMENT BOXES, ETC. MUST BE CONNECTED TO A
SOLID, INSULATED GREEN, COPPER GROUNDING CONDUCTOR. THIS GROUNDING
CONDUCTOR MUST BE CONTINUOUS WITHOUT SPLICES FROM POINT OF ORIGIN IN
PANELBOARD TO ALL BOXES AND EQUIPMENT ON EACH BRANCH CIRCUIT. VERIFY
GROUNDING VALUES.
13. FIRESTOP ALL NEW AND EXISTING FLOOR SLAB/CEILING AND WALL PENETRATIONS TO
MAINTAIN THE FIRE RATED CONSTRUCTION (REFER TO SPECIFICATIONS).
14. AFTER CONSTRUCTION, ALL UNUSED SPACES IN PANELS INVOLVED IN THE CONTRACT
SHALL BE LABELED AS A 'PROVISIONS', ALL SPARE BREAKERS SHALL BE PLACED IN THE
OFF POSITION AND LABELED AS 'SPARE'.
15. EXISTING REMOVED ELECTRICAL EQUIPMENT, MATERIALS AND OTHER USEFUL
ELECTRICAL ITEMS SHALL REMAIN THE PROPERTY OF THE OWNER AND SHALL BE
TRANSPORTED AND STORED AT THE SITE WHERE DIRECTED BY THE OWNER. THE
OWNER HAS FIRST RIGHT OF REFUSAL OF EXISTING EQUIPMENT AND MATERIALS.
ITEMS NOTED, TO BE RETAINED BY THE OWNER, SHALL REMAIN THE PROPERTY OF THE
OWNER AND SHALL BE STORED AS COMPLETE UNITS WITH ALL ASSOCIATED
ACCESSORIES AND ASSOCIATED EQUIPMENT. THE EQUIPMENT AND MATERIALS SHALL
BE DISCONNECTED AND CAREFULLY REMOVED UNDER THIS CONTRACT AND SHALL BE
TRANSPORTED TO THE STORAGE AREA AS DIRECTED. THE EQUIPMENT SHALL BE
STORED IN A NEAT MANNER, TAGGED AND IDENTIFIED FOR FUTURE USE BY THE
OWNER. REMOVED CONDUIT, WIRING AND OTHER MISCELLANEOUS ELECTRICAL
MATERIALS AND EQUIPMENT NOT TO BE RETAINED BY THE OWNER AND WHICH ARE NO
LONGER REQUIRED AS A PART OF THE NEW SYSTEMS SHALL BECOME THE PROPERTY
OF THE CONTRACTOR AND SHALL BE IMMEDIATELY REMOVED FROM THE SITE.
Project No.:
Sheet No.:
M
AR
K D
AT
E
C O
M M
EN
TS
Date:
A
3000 WESTINGHOUSE DRIVE
SUITE 400
CRANBERRY TWP, PA 16066
(877) 323-6603
© Larson Design Group 2026
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
SEAL
Larson Design Group
/1 9/
:2 2:
A
M P
:\5
5\
5-
\P ar k B at hr oo m
A D
A P ro je ct \D
W G
\R ev it\
-0
5_
M o n tg om er y P a rk
_M E
P F
.r vt
5835-005
E-001
M O
N
TG
O M
ER
Y
PA
R
K B
A
TH
R O
O M
A D
A
IN
TE
R
IO
R
IM
PR
O
VE
M
EN
TS
1S T
ST
, M
O N
TG
O
M
ER
Y, P
A
10-19-2026
EL
EC
TR
IC
A L
-S
YM
B O
LS
G
EN
ER
A
L N
O
TE
S
IS
SU
ED
F
O R
B
ID
D
IN
G
M O
N
TG
O M
ER
Y
B O
R O
U G
H
S O
U
TH
M
AI
N S
TR
EE
T M
O N
TG
O
M
ER
Y, P
A
0-
-2
IS
S U
E D
F O
R B
ID
D
EXISTING DOME PENDANT LIGHT FIXTURE TO
BE REPLACED WITH PORCELAIN LIGHT SOCKET
(TYP.)
EXISTING PROCELAIN LIGHT
SOCKET TO REMAIN (TYP.)
PLAN NOTES
1. ALL ELECTRICAL WORK SHALL BE INSTALLED IN
ACCORDANCE WITH THE LATEST NATIONAL ELECTRICAL
CODE AND ALL APPLICABLE FEDERAL, STATE, AND
LOCAL CODES.
3/4" = 1'-0"A1 ELECTRICAL DEMO - LIGHTING PLAN
N
Project No.:
Sheet No.:
M
AR
K D
AT
E
C O
M M
EN
TS
Date:
A
3000 WESTINGHOUSE DRIVE
SUITE 400
CRANBERRY TWP, PA 16066
(877) 323-6603
© Larson Design Group 2026
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
SEAL
Larson Design Group
/1 9/
:2 2:
A
M P
:\5
5\
5-
\P ar k B at hr oo m
A D
A P ro je ct \D
W G
\R ev it\
-0
5_
M o n tg om er y P a rk
_M E
P F
.r vt
5835-005
ED111
M O
N
TG
O M
ER
Y
PA
R
K B
A
TH
R O
O M
A D
A
IN
TE
R
IO
R
IM
PR
O
VE
M
EN
TS
1S T
ST
, M
O N
TG
O
M
ER
Y, P
A
10-19-2026
EL
EC
TR
IC
A L
D
EM
O
LI
G
H
TI
N G
P
LA
N
IS
SU
ED
F
O R
B
ID
D
IN
G
M O
N
TG
O M
ER
Y
B O
R O
U G
H
S O
U
TH
M
AI
N S
TR
EE
T M
O N
TG
O
M
ER
Y, P
A
KEY NOTES
SCALE:
1'-0" 2'-0" 4'-0"
3/4" = 1'-0"
0-
-2
IS
S U
E D
F O
R B
ID
D
NEW PORCELAIN LIGHT SOCKET (TYP.)
EXISTING PROCELAIN LIGHT
SOCKET TO REMAIN (TYP.)
PLAN NOTES
1. ALL ELECTRICAL WORK SHALL BE INSTALLED IN
ACCORDANCE WITH THE LATEST NATIONAL ELECTRICAL
CODE AND ALL APPLICABLE FEDERAL, STATE, AND
LOCAL CODES.
3/4" = 1'-0"
ELECTRICAL LIGHTING PLANA1
N
Project No.:
Sheet No.:
M
AR
K D
AT
E
C O
M M
EN
TS
Date:
A
3000 WESTINGHOUSE DRIVE
SUITE 400
CRANBERRY TWP, PA 16066
(877) 323-6603
© Larson Design Group 2026
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
SEAL
Larson Design Group
/1 9/
:2 2:
A
M P
:\5
5\
5-
\P ar k B at hr oo m
A D
A P ro je ct \D
W G
\R ev it\
-0
5_
M o n tg om er y P a rk
_M E
P F
.r vt
5835-005
EL111
M O
N
TG
O M
ER
Y
PA
R
K B
A
TH
R O
O M
A D
A
IN
TE
R
IO
R
IM
PR
O
VE
M
EN
TS
1S T
ST
, M
O N
TG
O
M
ER
Y, P
A
10-19-2026
EL
EC
TR
IC
A L
LI
G
H
TI
N G
P
LA
N
IS
SU
ED
F
O R
B
ID
D
IN
G
M O
N
TG
O M
ER
Y
B O
R O
U G
H
S O
U
TH
M
AI
N S
TR
EE
T M
O N
TG
O
M
ER
Y, P
A
KEY NOTES
SCALE:
1'-0" 2'-0" 4'-0"
3/4" = 1'-0"
0-
-2
IS
S U
E D
F O
R B
ID
D
T/P
S
M
S
T/P
EM
TP
W
IR
S
S
CA
CD
CW
F-CW
NPW
S-CW
HW
HW 140°
HW-R
HW-R 140°
GV
GW
G
OV
OW
PD
V
SS
SHWR
SHWS
SD
OSD
PLUMBING SYMBOLS
* NOTE *
ALL GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS IN THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE USED IN THIS SET OF
DRAWINGS.
LP
FLOOR DRAIN
RO
ID
6" SD-1
0" FD-2
3" AD-1
3" FS-1
6" DD-1
3" HD-1
PLUMBING FIXTURE NOTES
FLOOR DRAIN W/ TRAP PRIMER
"P" INDICATES PRIMER CONNECTION
8" SD-12
RAINFALL SURFACE AREA
PIPE ACCESSORY NOTES
FLOOR DRAIN W/ DEEP SEAL TRAP
FLOOR DRAIN W/ INTEGRAL CLEANOUT
2" FD-3P
4" FCO
AREA DRAIN (NO TRAP)
2" CHECK
2" BALANCE
2" CIRC
1" T/V
2" GATE
2" PRV
2" STRAIN
2" QUICK
2" M-CNTRL
2" S/O
TMVTMV-T/P
TMV-EM
PRIMER
2" METER
1 1/2" METER
1" GAS-CNTRL
2" BACKWATER
ALTERNATE CHECK VALVE
1" REG
1" GAS COCK
1" PLUG
DOUBLE CHECK VALVE
REDUCED PRESSURE ZONE
WV
(E)
2"
EXISTING PIPE TO REMAIN
PIPE TO BE DEMOLISHED
ABOVE GROUND PIPING
NOMINAL PIPE SIZE
BELOW GROUND PIPING
PIPE SLOPE (WHEN APPLICABLE)1/8" / 12" SLOPE
CLEANOUT
SWING CHECK
CHECK VALVE
BALANCING VALVE
CIRCUIT SETTER
GATE VALVE
QUICK OPENING VALVE
BALL VALVE
FLUID STRAINER
THERMOSTATIC VALVE
TRAP PRIMER
ELEC. CONTROL VALVE
MIXING VALVE
EMERGENCY MIXER
PRESSURE REDUCING VALVE
WATER METER
IRRIGATION METER
GAS REGULATOR
GAS SHUTOFF COCK
PLUG VALVE
EMERGENCY GAS SHUTOFF
2" CHECK
CWV
2" FD-3
2" FD-1
HUB DRAIN (FUNNEL TYPE)
ABBREVIATIONS
KEYNOTE SYMBOL
CONTINUATION SYMBOL
SHEET NUMBER WHERE DETAIL IS PLACED
DETAIL NUMBER ON SHEET
REVISION
GENERAL PLAN SYMBOLS
ROOM NAME / NUMBER
POINT WHERE NEW CONNECTS TO EXISTING
AREA NOT IN CONTRACT
SHEET NUMBER WHERE SECTION IS PLACED
SECTION NUMBER ON SHEET
CONSTRUCTION NOTE SYMBOL##
POINT WHERE DEMOLITION ENDS
DEMOLITION NOTE SYMBOL##
FLOOR SINK
ROOF DRAIN
DECK DRAIN
ROOM
PIPE RISE / PIPE DROP
PIPE CAP
CONTINUATION BREAK
CONNECT TO EXISTING
DIRECTION OF FLOW
FLEXIBLE CONNECTION
TEE TURNED DOWN / TEE
TURNED UP
2" BFV BUTTERFLY VALVE
2" GLOBE GLOBE VALVE
2" SOL SOLENOID VALVE
EXPANSION JOINT
UNION
2" WH WATER HAMMER
PIPE TYPES
CONSTRUCTION PHASING
EXISTING TO BE DEMOLISHED
NEW
(TYPICAL ALL SYMBOLS AND EQUIPMENT)
EXISTING
AREA BEING DEMOLISHED
DOMESTIC COLD-WATER
NON-POTABLE WATER
SOFT COLD-WATER
FILTERED COLD-WATER
REVERSE OSMOSIS WATER
DOMESTIC HOT-WATER
DOMESTIC HOT-WATER 140°
HOT-WATER RECIRCULATION
HOT-WATER RECIRCULATION 140°
SANITARY DRAIN
SANITARY VENT
SANITARY WET VENT
COMBINATION DWV
CONDENSATE DRAIN
INDIRECT DRAIN
GREASE WASTE
GREASE VENT
OIL WASTE
OIL VENT
PUMP DISCHARGE
SOLAR WATER RETURN
SOLAR WATER SUPPLY
STORM DRAIN
STORM OVERFLOW
COMPRESSED AIR
NATRUAL GAS
LIQUID PROPANE
XX.XX
PLUMBING GENERAL NOTES
1. IT IS INTENDED THAT A COMPLETE PLUMBING SYSTEM BE PROVIDED WITH ALL NECESSARY
EQUIPMENT, APPURTENANCES AND CONTROLS. THE CONTRACTOR MUST CAREFULLY REVIEW ALL
THE CONTRACT DOCUMENTS AND COORDINATE BETWEEN ALL TRADES PRIOR TO SUBMITTING SHOP DRAWINGS. THE CONTRACTOR MUST VERIFY ALL SIZES, MATERIALS, TEMPERATURE AND PRESSURE
RATINGS BEFORE ORDERING OR INSTALLING ANY MATERIALS OR EQUIPMENT.
2. THE CONTRACTOR MUST FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OR PURCHASE OF EQUIPMENT, MATERIALS AND ASSEMBLIES. THERE MAY EXIST FIELD CONDITIONS WHICH DIFFER
FROM THOSE SHOWN ON THESE DRAWINGS. ANY SUCH DEVIATIONS MUST BE BROUGHT TO THE
ATTENTION OF THE OWNER FOR RESOLUTION BEFORE PROCEEDING WITH ANY CONSTRUCTION,
FABRICATION, OR MATERIAL/EQUIPMENT PURCHASE WHICH WOULD BE UNUSABLE UNDER THOSE
CIRCUMSTANCES.
3. UNLESS NOTED OTHERWISE, CONSTRUCTION MATERIAL AND EQUIPMENT REMOVED SHALL BECOME
THE PROPERTY OF THE CONTRACTOR AND SHALL BE LEGALLY DISPOSED OF OFF THE SITE.
4. COORDINATE WORK WITH STRUCTURAL, DUCTWORK, SPRINKLER, ELECTRICAL AND ARCHITECTURAL
FEATURES AND PROVIDE OFFSETS AND FITTINGS AS REQUIRED.
5. COORDINATE WORK WITH ALL OTHER TRADES. CEILING HEIGHTS ON ARCHITECTURAL PLANS ARE
FINAL.
6. INSTALL ALL WORK IN ACCORDANCE WITH ALL APPLICABLE CODES AND REGULATIONS.
7. CONTRACTOR SHALL VERIFY LOCATION OF EXISTING UNDERGROUND UTILITIES AND PIPING BEFORE
COMMENCING WORK.
8. CONTRACTOR IS REQUIRED TO NOTIFY FACILITY OWNERS NOT LESS THAN 3 AND NOT MORE THAN 10
WORKING DAYS PRIOR TO EXCAVATION OR DEMOLITION WORK WHEN USING POWERED EQUIPMENT.
9. COORDINATE LOCATION OF ALL PIPING AND DEVICES BEFORE INSTALLATION WITH THE WORK OF
OTHER TRADES. WHERE A CONFLICT IN AVAILABLE CLEARANCES OCCURS, OBTAIN CLARIFICATION FROM OTHER TRADES OR ARCHITECT, AND PROVIDE WHATEVER ADDITIONAL PIPING, FITTINGS, ETC., ARE REQUIRED TO INSTALL PLUMBING SYSTEM.
10. VERIFY MOUNTING HEIGHTS OF EQUIPMENT FIXTURES W/ARCHITECT DRAWING BEFORE ROUGH-IN.
11. BUILDING STORM WATER, DOMESTIC WATER, SANITARY, & GAS PIPING SHALL BE EXTENDED TO LIMIT
DELINEATION OF CONTRACT LINE AS INDICATED ON DRAWINGS.
12. THE PLUMBING CONTRACTOR SHALL MAKE A COMPLETE WASTE, VENT, HOT & COLD WATER
CONNECTION TO ALL OWNER FURNISHED EQUIPMENT.
13. INSTALL ALL PLUMBING EQUIPMENT AND MATERIALS IN STRICT ACCORDANCE WITH RESPECTIVE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
14. DIMENSIONS AND PIPE SIZES ARE IN INCHES UNLESS NOTED OTHERWISE.
15. RUN PIPING CONCEALED EXCEPT IN MECHANICAL ROOMS OR WHERE NOTED OTHERWISE.
16. RUN CONCEALED PIPING ON ROOM SIDE OF BUILDING INSULATION UNLESS NOTED OTHERWISE.
17. ALL EXPOSED PIPING SHALL BE CLEANED AND HAVE THE SURFACE PREPARED TO RECEIVE PAINTED
FINISH. PRIME AND PAINT THE EXPOSED PIPING IN COLOR AS SELECTED BY THE ARCHITECT.
18. RUN 2" MINIMUM SIZE WASTE PIPING BELOW GROUND INSIDE BUILDING REGARDLESS OF SIZE NOTED
ON FIXTURE SCHEDULE.
19. CONNECT WATER, WASTE, AND VENT PIPING TO FIXTURES IN ACCORDANCE WITH SIZES INDICATED
ON FIXTURE SCHEDULE.
20. SEAL ALL FLOOR AND WALL PENETRATIONS IN FIRE RATED CEILINGS AND PARTITIONS TO MAINTAIN
FIRE RATING. COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS.
21. COORDINATE ACCESS PANELS AND DOORS WITH ARCHITECT FEATURES.
22. CONTRACTOR SHALL PROVIDE PIPE SLEEVES IN ALL FOUNDATION WALLS FOR PIPING
PENETRATIONS.
23. ALL DOMESTIC WATER PIPING SHALL BE INSTALLED AS HIGH AS POSSIBLE, UNLESS OTHERWISE
INDICATED.
24. MAKE ALL FINAL CONNECTIONS TO THE EQUIPMENT AS SHOWN ON THE DRAWINGS. PROVIDE SHUT-
OFF VALVES IN ALL INDIVIDUAL WATER CONNECTIONS. IF APPLICABLE, PROVIDE SHUT-OFF VALVES IN
ALL INDIVIDUAL GAS CONNECTIONS.
25. INSTALL VACUUM BREAKER ON ALL DRAIN VALVES, WALL HYDRANTS, AND ALL HOSE CONNECTIONS.
26. FURNISH AND INSTALL ACCESS PANELS (FIRE-RATED) WHERE REQUIRED, WHERE SHOWN, OR
REQUIRED FOR ACCESS TO ALL CONCEALED VALVES, TRAPS OR OTHER EQUIPMENT FURNISHED
UNDER THIS CONTRACT WHERE NO OTHER MEANS IS PROVIDED.
27. INSTALL UNIONS ON PIPING TO PERMIT EASY DISCONNECTING.
28. THE CONTRACTOR SHALL RIGIDLY SUPPORT ALL EQUIPMENT.
29. ALL SANITARY AND STORM SEWER PIPING SHALL BE RUN AT 1/8" PER FOOT SLOPE UNLESS
OTHERWISE NOTED. ALL GREASE WASTE PIPING AND ALL SANITARY SEWER PIPING 2" AND SMALLER
SHALL BE RUN AT 1/4" PER FOOT SLOPE.
30. PROVIDE AND INSTALL ANGLE SHUTOFF VALVES AT EACH FIXTURE REQUIRING WATER. VALVES FOR
WALL MOUNTED FIXTURES SHALL BE CHROME PLATED, THREADED, HEAVY DUTY TYPE AND HAVE
LOOSE KEY STOPS. VALVES FOR COUNTERTOP FIXTURES SHALL BE 1/4 TURN BALL VALVES. PROVIDE SHUT-OFF VALVE IN ALL HOT WATER SUPPLY BRANCHES AND COMBINATION SHUT-OFF AND BALANCE VALVE IN ALL HOT WATER RETURN BRANCHES. LOCATE IN ACCESSIBLE CEILING SPACE OR IF INSIDE
EQUIPMENT ENCLOSURES, PROVIDE ACCESS DOOR.
31. DO NOT PLACE PIPING ABOVE ELECTRICAL PANELS, COMMUNICATIONS OR DATA EQUIPMENT.
32. COORDINATE THE EXACT LOCATION OF ALL ROOF OPENINGS AND SLAB PENETRATIONS WITH THE
STRUCTURAL DRAWINGS PRIOR TO INSTALLATION OF PLUMBING WORK.
33. UPON COMPLETED INSTALLATION, DRINKING WATER MUST BE TESTED FOR PH, LEAD, COPPER AND
TOTAL COLIFORMS. TESTING MUST BE CONDUCTED PRIOR TO THE CONTRACTOR ACCEPTANCE
INSPECTION.
34. EQUIPMENT SIZES SHOWN ARE BASED UPON TYPICAL MANUFACTURED EQUIPMENT AVAILABLE.
SHOP DRAWINGS MUST BE PROVIDED FOR REVIEW AND APPROVAL, SHOWING SPACE FOR ACCESS, EGRESS, MAINTENANCE AND REQUIRED CODE CLEARANCES PRIOR TO ANY PROCUREMENT, FABRICATION OR INSTALLATION.
Project No.:
Sheet No.:
M
AR
K D
AT
E
C O
M M
EN
TS
Date:
A
3000 WESTINGHOUSE DRIVE
SUITE 400
CRANBERRY TWP, PA 16066
(877) 323-6603
© Larson Design Group 2026
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
SEAL
Larson Design Group
/1 9/
:2 2:
A
M P
:\5
5\
5-
\P ar k B at hr oo m
A D
A P ro je ct \D
W G
\R ev it\
-0
5_
M o n tg om er y P a rk
_M E
P F
.r vt
5835-005
P-001
M O
N
TG
O M
ER
Y
PA
R
K B
A
TH
R O
O M
A D
A
IN
TE
R
IO
R
IM
PR
O
VE
M
EN
TS
1S T
ST
, M
O N
TG
O
M
ER
Y, P
A
10-19-2026
PL
U
M B
IN
G
G
EN
ER
A L
N O
TE
S, S
YM
B O
LS
A B
B R
EV
IA
TI
O
N S
IS
SU
ED
F
O R
B
ID
D
IN
G
M O
N
TG
O M
ER
Y
B O
R O
U G
H
S O
U
TH
M
AI
N S
TR
EE
T M
O N
TG
O
M
ER
Y, P
A
ABB DESCRIPTION
__________ A __________
& AND
< ANGLE
@ AT
AB CL ABOVE CEILING
AD ACCESS DOOR/AREA DRAIN
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
APPROX APPROXIMATE(LY)
ARCH ARCHITECT OR ARCHITECTURAL
AV ACID VENT, AUTOMATIC AIR VENT,
AUDIO VISUAL
AW ACID WASTE
__________ B __________
B/ BOTTOM OF
BET BETWEEN
BFG BELOW FINISHED GRADE
BFP BACKFLOW PREVENTER
BLW BELOW
BOS BOTTOM OF STRUCTURE
BOT BOTTOM
BTU BRITISH THERMAL UNIT
__________ C __________
CA COMPRESSED AIR
CD CONDENSATED DRAIN/CEILING
DIFFUSER
CF/CI CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED, OWNER
INSTALLED
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CI CAST IRON
CO CLEAN OUT, CLEAR OPENING
CONC CONCRETE
CW COLD WATER - DOMESTIC
__________ D __________
DDC DIRECT DIGITAL CONTROL, DOUBLE
DETECTOR CHECK VALVE
DF DRINKING FOUNTAIN
DIP DUCTILE IRON PIPE
DN DOWN
DST DEEP SEAL TRAP
__________ E __________
EC ELECTRICAL CONTRACTOR
EES EMERGENCY EYEWASH AND
SHOWER
ENGR ENGINEER
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EXIST EXISTING
__________ F __________
FCO FLOOR CLEANOUT
FD FLOOR DRAIN, FIRE DAMPER
FD/T FLOOR DRAIN WITH TRAP PRIMER
FFE FINISHED FLOOR ELEVATION
FLR FLOOR
ABB DESCRIPTION
FS FLOOR SINK
__________ G __________
GC GENERAL CONTRACTOR
GH GROUND HYDRANT
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GW GREASE WASTE
GWH GAS WATER HEATER
__________ H __________
HB HOSE BIBB
HP HORSEPOWER
HW HOT WATER
HWR HOT WATER RETURN
__________ I __________
INV INVERT
__________ K __________
KVAR KILOVOLT-AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
__________ L __________
LAV LAVATORY
LD LINEAR DRAIN
__________ M __________
MB MOP BASIN
MC MECHANICAL CONTRACTOR
__________ N __________
NC NORMALLY CLOSED
NFWH NON-FREEZE WALL HYDRANT
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
__________ O __________
OD OUTSIDE DIAMETER / OVERFLOW
DRAIN
OS&Y OUTSIDE STEM & YOKE
__________ P __________
P PRESSURE GAUGE
PC PLUMBING CONTRACTOR
PD PRESSURE DROP
PRV PRESSURE REDUCING VALVE,
POWER ROOF VENTILATOR
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PVC POLYVINYL CHLORIDE (CONDUIT)
PΔ PRESSURE DIFFERENCE
__________ R __________
RCP REFLECTED CEILING PLAN /
RECIRCULATION PUMP
RD ROOF DRAIN
RPM REVOLUTIONS PER MINUTE
RWC RAIN WATER CONDUCTOR
__________ S __________
S SOUTH, SOIL LINE, STACK, SINK
SD SMOKE DAMPER / SMOKE DETECTOR
/ SHOWER DRAIN
SH SHOWER
SK SERVICE SINK
SS SANITARY SEWER, STAINLESS STEEL
STD STANDARD
__________ T __________
T TREAD / TEMPERATURE /
THERMOMETER
TD TEMPERATURE DROP / TRENCH
DRAIN
TMW THERMAL MIXING VALVE
TYP TYPICAL
TΔ TEMPERATURE DIFFERENCE
__________ U __________
UNO UNLESS NOTED OTHERWISE
UR URINAL
__________ V __________
V VENT, VOLT
VIF VERIFY IN FIELD
VTR VENT THRU ROOF
__________ W __________
W WEST / WASTE
W/ WITH
W/O WITHOUT
WC WATER CLOSET / WATER COLUMN
WF WIDE FLANGE / WATER FOUNTAIN
WH WATER HEATER / WALL HYDRANT
WHA WATER HAMMER ARRESTOR
0-
-2
IS
S U
E D
F O
R B
ID
D
GENERAL REQUIREMENTS
A. GENERAL
1. CONFORM TO ALL GENERAL AND SPECIAL CONDITIONS OF CONTRACT AS SPECIFIED BY SITE ENGINEER’S AND/OR
OWNER.
2. VISIT SITE, CHECK FACILITIES AND CONDITIONS AND MAKE ALL NECESSARY OBSERVATIONS AND MEASUREMENTS. NOTE CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED AND TAKE ALL ITEMS INTO
CONSIDERATION IN BID.
3. SYSTEMS ARE TO BE COMPLETE AND WORKABLE IN ALL RESPECTS, PLACED IN OPERATION AND PROPERLY
ADJUSTED.
4. CONTRACTOR SHALL PROVIDE HIS OWN CLEAN-UP, REMOVAL AND LEGAL DISPOSAL OF ALL RUBBISH DAILY.
5. CONTRACTOR SHALL PROTECT HIS WORK, HIS EXISTING AND ADJACENT PROPERTY AGAINST WEATHER.
6. CONTRACTOR SHALL PROTECT HIS WORK, MATERIALS, APPARATUS AND FIXTURES FROM DAMAGE. ANY WORK DAMAGED BY FAILURE TO PROVIDE PROTECTION REQUIRED, SHALL BE REMOVED AND REPLACED WITH NEW
MATERIAL AT THE CONTRACTOR'S EXPENSE.
7. ARRANGE FOR AND OBTAIN OWNER'S AND INSURANCE REPRESENTATIVE'S PERMISSION FOR ANY SERVICE
SHUTDOWNS.
8. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, SEQUENCES OF
CONSTRUCTION AND THE SAFETY OF WORKMEN.
9. NO PIPING, DUCTWORK, WIRING, ETC. SHALL BE INSTALLED OR ROUTED ABOVE ELECTRICAL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .