1-5835-005 MontgomeryParkADA Drawings IFB.pdf

PDF 4 MB Posted

Attached to
Montgomery Park ADA Bathroom – Interior Improvement Project
Solicitation number
US.258297
Issued by
Lycoming County, Pennsylvania

About this file

This file contains architectural bidding drawings for the Montgomery Park ADA Bathroom – Interior Improvement Project prepared by Larson Design Group for Montgomery Borough, Pennsylvania, located at 119 1st Street, Montgomery, PA 17752. The drawings, issued for bidding on October 19, 2026, depict interior improvements for bathroom accessibility modifications in compliance with Americans with Disabilities Act (ADA) standards. The document includes general notes and legends detailing specific ADA compliance requirements for casework, appliances, doors, hardware, shelves, closets, thresholds, level changes, protruding objects, and reach requirements. Key specifications include storage accessibility standards (ANSI 804.5), appliance accessibility requirements (ANSI 804.6), fixture height limitations not to exceed 34 inches, door hardware specifications requiring lever-type devices mounted at 34 to 48 inches above finished floor with maximum 5-pound effort to operate interior doors, and detailed ramp specifications with minimum 36-inch clear width and maximum 38-inch height. The drawings establish precise measurements for reach requirements, clear floor spaces, and accessible routes throughout the facility.

The bidding drawings reference Project No. 5835-005 and include detailed dimensional specifications and compliance standards necessary for contractors to prepare accurate construction bids. These technical drawings serve as the basis for the sealed bid solicitation, with bids due electronically via PennBid by 11:00 A.M. on November 20, 2026, and a pre-bid conference scheduled for November 5, 2026, at the Montgomery Borough Office. The drawings confirm that this is an interior improvement project focused exclusively on ADA bathroom accessibility compliance, with no exterior construction or site work elements included.

View the file

Other files

File Type Posted
2-5835-005 MontgomeryParkADA Project Manual IFB.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MA

RK

DA

TE

CO

MM

EN

TS

© Larson Design Group 2026

P:

\58

\58

-0

\P ar k B ath ro om A

DA

P ro jec t\D W

G\

-0

_C

-1

.dw g, G-

1 -

IN

T, /19 /20

7:

:33

A M, F os ter , K ay ley

Project No.:

Sheet No.:

Date:

1 2 3 4 5 6 7 8 9 10

G

F

E

D

C

B

A

SEAL

3000 WESTINGHOUSE DRIVE

SUITE 400

CRANBERRY TWP, PA 16066

(877) 323-6603

Larson Design Group

5835-005

MO

NT

GO

ME

RY

P

AR

K

BA

TH

RO

OM

A

DA

9 F

IR

ST

S

TR

EE

, M

ON

TG

OM

ER

Y, P

A

10-19-2026

IS

SU

ED

F

OR

B

ID

DI

NG

MO

NT

GO

ME

RY

B

OR

OU

GH

S

OU

TH

M

AI

N

ST

RE

ET

MO

NT

GO

ME

RY

, P A

-1 9-

IS

SU

ED

F

OR

B

ID

DI

NG

IN

TE

R

IO

R

IM

PR

O

VE

M

EN

TS

G-001

C O

VE

R

S H

EE

T

MONTGOMERY BOROUGH

35 SOUTH MAIN STREET

MONTGOMERY, PA 17752

BIDDING DRAWINGS

MONGOMERY PARK BATHROOM ADA - INTERIOR IMPROVEMENTS

119 1ST STREET, MONTGOMERY, PA 17752

5835-005

MA

RK

DA

TE

CO

MM

EN

TS

© Larson Design Group 2026

P:

\58

\58

-0

\P ar k B ath ro om A

DA

P ro jec t\D W

G\

-0

_C

-1

.dw g, G-

2, /19 /20

7:

:10

A M, F os ter , K ay ley

Project No.:

Sheet No.:

Date:

1 2 3 4 5 6 7 8 9 10

G

F

E

D

C

B

A

SEAL

3000 WESTINGHOUSE DRIVE

SUITE 400

CRANBERRY TWP, PA 16066

(877) 323-6603

Larson Design Group

5835-005

MO

NT

GO

ME

RY

P

AR

K

BA

TH

RO

OM

A

DA

9 F

IR

ST

S

TR

EE

, M

ON

TG

OM

ER

Y, P

A

10-19-2026

IS

SU

ED

F

OR

B

ID

DI

NG

MO

NT

GO

ME

RY

B

OR

OU

GH

S

OU

TH

M

AI

N

ST

RE

ET

MO

NT

GO

ME

RY

, P A

-1 9-

IS

SU

ED

F

OR

B

ID

DI

NG

IN

TE

R

IO

R

IM

PR

O

VE

M

EN

TS

G-002

G

EN

ER

A

L N

O

TE

S A

N D

L

EG

EN

D

FEMA FIRM MAP

MAP NUMBER:

USGS QUADRANGLE MAP

MAP SCALE:

MAP SCALE:

MAP SCALE:

X

FM

G

S

W

SFF

LOD

PERMIT

E

T

V

CS-8

CS-12

CS-18

CS-24

OH

1" = 2000'

1" = 500' 42081C0516F

MUNCY

NOTES:

1. 50% OF ALL STORAGE MUST BE ACCESSIBLE AND MEET REACH

REQUIREMENTS (ANSI 804.5).

2. FORWARD APPROACH KNEE AND TOE CLEARANCE NOT REQUIRED

FOR KITCHEN SINKS WHERE A COOK TOP OR RANGE IS NOT

PROVIDED OR AT WET BARS (ANSI 606.2).

3. APPLIANCES MUST BE ACCESSIBLE (ANSI 804.6).

4. LAVATORY, SINK AND OTHER FIXTURES MUST NOT EXCEED 34" IN

HEIGHT. VERIFY EXACT FIXTURE DIMENSIONS PRIOR TO

FABRICATION & INSTALLATION OF CABINETRY AND COUNTERTOP.

SEE NOTE #1

SEE NOTE #3 SEE NOTE #4

FORWARD APPROACH

REQUIREMENTS (SEE NOTE #2)

50% OF REFRIGERATOR/FREEZER

MUST BE 54% MAX HEIGHT AFF

(ANSI 804.6.6)

" M

AX

" M

AX

30" CLR

" M

AX

" M

AX

" M

AX

CASEWORK AND APPLIANCES DOORS AND HARDWARE

DOOR TYPE:

1. MINIMUM 10" HIGH SMOOTH SURFACE AT DOOR BOTTOM, EITHER ATTACHED PANEL OR

BOTTOM RAIL.

HARDWARE:

1. OPENABLE FROM INSIDE WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT.

2. OPENABLE BY SINGLE EFFORT LEVER-TYPE DEVICE (NOT REQUIRING GRASPING).

3. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE HARDWARE TO BE MOUNTED

AT 34"

4. MAXIMUM 8.5 LBS EFFORT TO OPERATE EXTERIOR DOOR; 5 LBS FOR INTERIOR DOOR.

(WHERE INDICATED)

A NARROW FRAME WITH A

BEVELED TOP EDGE

(60) DEGREE MAXIMUM BEVEL TO

HORIZONTAL PLANE)

INSTALLED AT THE BOTTOM OF A

GLASS DOOR

(WITH NO SIDE FRAMES) MAY BE

USED IN LIEU OF PROVIDING THE

REQUIRES 10-INCH

UNINTERRUPTED SURFACE AT THE

BOTTOM OF THE DOOR.

LEVER OR U

SHAPED HANDLE

MOUNTED AT 34"

TO 48" AFF

BO

T

R

AI

L

" M

IN

21" MAX 21" MAX

M

IN

9"

" M

AX

> 10"

SHELVES AND CLOSETS

THRESHOLD AND LEVEL CHANGES

COMPRESSED CARPET 1/4"

MAX BELOW THRESHOLD

THRESHOLD

FIN FLOOR

LEVEL

PI

LE

H

EI

G H

T 1/

2" M

IN

TRANSITION BETWEEN FLOOR FINISHES

DOOR THRESHOLD

1/ 4"

M

AX

1/ 2"

M

AX

11/

4" M

AX

1/ 2"

M

AX

LEVEL CHANGES

NOTES:

1. 1/2" MAXIMUM TOTAL HEIGHT WITH 1.4" MAXIMUM VERTICAL

CHANGE AT EDGE.

2. 1:2 SLOPED BEVEL REQUIRED IF LEVEL CHANGE IS OVER 1/4"

VERTICAL.

3. LEVEL CHANGES OF MORE THAN 1/2" MUST BE RAMPED AND

COMPLY WITH RAMP REQUIREMENTS.

PROTRUDING OBJECTS

" M

IN

4" MAX

>2 7"

FIG (A)

" M

AX

FIG (B)

WIDTH

ACCESSIBLE AMOUNT

ANY

FIG (C)

" M

AX

CANE RANGE

FIG (D)

" M

AX

CANE RANGE

POST

12" MAX

REACH REQUIREMENTS

" M

AX

48"

" M

IN

HIGH FORWARD REACH LIMIT

48"

NOTES:

1. X MUST BE < 25 INCHES; Z MUST BE > X.

2. WHEN X < 20 INCHES, THEN Y MUST BE 48 INCHES MAX.

3. WHEN X IA > 20 TO 25 INCHES, THEN Y MUST BE 44 INCHES MAX.

MAXIMUM FORWARD REACH OVER AN OBSTRUCTION

(X)

(Y

(Z)

(Z)

30"

" M

IN

" M

AX

CLEAR FLOOR SPACE PARALLEL APPROACH HIGH AND LOW SIDE REACH LIMITS

" M

AX

SIDE REACH OVER AN OBSTRUCTION

" M

AX

10" MAX 30"

" M

AX

" M

AX

24" MAX

>10" MIN

30"

RAMPS

PLACE BOTTOM RAIL SO THAT

A 4" DIA SPHERE CANNOT

PASS THROUGH THE RAILING

UP TO 4" ABOVE RAMP

" M

IN

36" MIN CLEAR

" M

AX

" M

IN

<4

NO BOTTOM RAIL IS

REQUIRED WHEN EDGES OF

RAMP EXTEND 12" MIN FROM

THE INSIDE OF THE RAILING

" M

IN

36" MIN CLEAR

" M

AX

" M

IN

12" MIN

RAMP SECTIONSTRAIGHT RAMP RUN

NOTE:

ALL RAMPS MUST MEET HANDRAIL AND CURB REQUIREMENTS.

WHEN DOOR, DISTANCES

MUST COMPLY WITH ADA

DOOR CLEARANCES

60" MIN

60" MIN

60"

MIN

60"

MIN

360" INTERVAL MAX

VARIES

360" INTERVAL MAX

VARIES

AS REQUIRED

30" MAX

RISE, TYP

WHEN DOOR, DISTANCES

MUST COMPLY WITH ADA

DOOR CLEARANCES

60" MIN

60" MIN

60"

MIN

AS REQUIRED

RAMP WITH INTERMEDIATE

SWITCH-BACK PLATFORM

30" MAX RISE, TYP

60" MIN

WHEN DOOR, DISTANCES

MUST COMPLY WITH ADA

DOOR CLEARANCES

60" MIN

60" MIN

60"

MIN

60"

MIN

360" INTERVAL MAX

VARIES

360" INTERVAL MAX

VARIES

60" MIN LANDING

30" MAX RISE, TYP

INTERMEDIATE

TURNING POSITION

RAMP WITH TURNING PLATFORM

AS REQ'D

60" MIN

INTERMEDIATE

PLATFORM

SIDEWALK DETAIL

POLE

CURB,

TYP

STREET,

TYP

SIDEWALKSIDEWALK

CLEAR

36" MIN

CLEAR

48" MIN

CLEAR

48" MIN

CLEAR

36" MIN

" M

AX

" M

IN 38

" M

AX

" M

IN

MIN

12" MIN

12"

RAMP HANDRAIL EXTENSIONS

" M

AX

(X)

360" INTERVAL

MAX VARIES, TYP

N O

TE

N O

T

AL

L

AC

C

ES

SA

BL

E C

O M

PO

N

EN

TS

M

AY

B E

U

SE

D

IN

T H

IS

P

R O

JE

C

T.

T

H

IS

S H

EE

T

IS

P

R O

VI

D

ED

F

O R

G

EN

ER

AL

R

EF

ER

EN

C E

O N

LY

Project No.:

Sheet No.:

M

AR

K D

AT

E

C O

M M

EN

TS

Date:

A

3000 WESTINGHOUSE DRIVE

SUITE 400

CRANBERRY TWP, PA 16066

(877) 323-6603

© Larson Design Group 2026

2 3 4 5 6 7 8 9 10

B

C

D

E

F

G

SEAL

Larson Design Group

/1 9/

9:

:0

A

M P

:\5

5\

5-

\P ar k B at hr oo m

A D

A P ro je ct \D

W G

\R ev it\

-0

5_

M o n tg om er y P a rk

_A

IS

.r vt

5835-005

G-003

M O

N

TG

O M

ER

Y

PA

R

K B

A

TH

R O

O M

A D

A

IN

TE

R

IO

R

IM

PR

O

VE

M

EN

TS

1S T

ST

, M

O N

TG

O

M

ER

Y, P

A

10-19-2026

A C

C

ES

SI

B

IL

IT

Y D

IA

G

R A

M S

IS

SU

ED

F

O R

B

ID

D

IN

G

M O

N

TG

O M

ER

Y

B O

R O

U G

H

S M

AI

N

S

TR

EE

T

M O

N

TG

O M

ER

Y, P A

0-

-2

IS

S U

E D

F O

R B

ID

D

G

TOILET ROOM FIXTURE HEIGHTS AND CLEARANCES

NOTES:

1. DIMS SHOWN ARE TO FACE OF FINISHED WALL/FLOOR/CEILING. VERIFY EXACT CLEARANCE PRIOR

TO INSTALLATION.

2. PROVIDE NON-ABSORBENT SURFACE MATERIAL UP TO 48" AND BASE UP TO 6" AFF UNO (TYP).

3. INSULATE EXPOSED WASTE AND WATER LINES BELOW LAVATORY (TYP).

4. 40" MIRROR MOUNTING HEIGHT MUST BE FROM FLOOR TO REFLECTIVE SURFACE.

5. TOILET TRIP LEVER MUST BE ON APPROACH SIDE OF FIXTURE. VERIFY PRIOR TO ORDERING.

6. GRAB BARS MUST HAVE A 250 LB WEIGHT CAPACITY.

" M

IN

30" MIN

VERIFY KNEE & TOE

CLEARANCES WITH

SPECIFIED FIXTURE

RE: MECH

NO FIXTURE

MAY OVERLAP

CLEARANCE

60" MIN

*5 9"

M

IN

* 56" AT WALL-HUNG TOILETS

URINAL CLEARANCE WATER CLOSET

CLEARANCE

WATER CLOSET

STALL CLEARANCE

" M

IN

*5

9" M

IN

60" MIN

SPACE (TYP)

6" TOE KICK

" M

IN

" M

IN

54" MIN

VERIFY KNEE & TOE

CLEARANCES WITH

SPECIFIED FIXTURE

RE: MECH

30" MIN

AMBULATORY STALL WATER CLOSET STALL

TOE CLEARANCE

LAVATORY

CLEARANCE

WATER FOUNTAINS

30"x48" CLEAR FLOOR SPACE

18" MIN24" MAX

17" - 19"

30" CLEAR

FOR SINGLE

6" MIN

15" MIN

5" MAX

9" MIN

1' -1

/2

" M

IN

HANDRAIL AND GRAB BAR MOUNTING

1 1/2" MAX

1 1/4" MIN

1 1/2"

4"-6 1/4"

PERIMETER

MAX

M

1/

2"

1 1/12" MAX

1 1/4" MIN

1 1/2"

" M

IN

1 1/2" MAX

1 1/4" MIN

1 1/2"

1 1/2"

" M

IN

1/ 2"

M

IN

HANDRAILS GRAB BARS NOTE:

NOT ALL ACCESSABLE COMPONENTS

MAY BE USED IN THIS PROJECT. THIS

SHEET IS PROVIDED FOR GENERAL

REFERENCE ONLY.

12" 42"

40" CL

CL

" M

AX

" M

IN

9" MAX

7" MIN

CL

" M

AX

" M

IN

15" 15"CL

URINALS WATER CLOSETS

18"

CL

24" 12"CL

CL

LAVATORIES

CLEARANCE

8" MIN KNEE

CLEARANCE

6" MAX TOE

" M

AX

R

EF

LE

C

TI

VE

S U

R

FA

C E

" M

AX

T

O

CL

15"

MAX

12" 24" MIN 24" MAX

EQ EQ

CL

5"

CL

ADJUSTABLE HGT HAND SHOWER W/

59" MIN LENGTH HOSE

BATHTUBS WITHOUT PERMANENT SEATS

" M

IN

MAX

12" 24" MIN 24" MAX

" M

6"

REMOVABLE SEAT

" M

IN

" M

IN

8" MAX

6" MAX

" M

AX

36"

" M

AX

" M

IN

17" MIN

9" M

IN

" M

IN

" M

IN

" M

AX

" M

AX

STAIRWAYS

STAIR HANDRAILS

PROVIDE SECOND SET OF

HANDRAILS AT 24" AFF WHEN

CHILDREN ARE PRIMARY USERS

12"

" M

AX

" M

IN

WIDTH

TREAD 12"

" M

AX

" M

IN

H

EA

D H

EI

G

H T

6' -8

" M

IN

TOP

LANDING

BOTTOM

LANDING

THE LEADING 2" (51 MM) OF THE

TREAD MUST HAVE VISUAL

CONTRAST OF DARK-ON-LIGHT OR

LIGHT-ON-DARK FROM THE

REMAINDER OF THE TREAD

(ICC/ANSI SECTION 504.5)

11" MIN

7" M

AX

4" M

IN

MAX

30°

1-1/2" MAX

1-1/2" MAX

STAIR RISERS AND TREAD

CURVED

NOSING

BEVELED

NOSING

1/2" RADIUS MAX

NOTE:

ALL HANDRAILS MUST RETURN TO POST, WALL OR FLOOR

3" MAX

PROTRUSION

4" MAX

8" MAX

4" M

AX

" M

IN

" M

AX

H

AN

D

R

AI

L

" M

IN

G

U

AR

D R

AI

L

OPEN STAIRS

SITE ELEMENTS

SEE CIVIL DRAWINGS FOR ALL SITE

RELATED ACCESSIBLE ELEMENTS

Project No.:

Sheet No.:

M

AR

K D

AT

E

C O

M M

EN

TS

Date:

A

3000 WESTINGHOUSE DRIVE

SUITE 400

CRANBERRY TWP, PA 16066

(877) 323-6603

© Larson Design Group 2026

2 3 4 5 6 7 8 9 10

B

C

D

E

F

G

SEAL

Larson Design Group

/1 9/

9:

:0

A

M P

:\5

5\

5-

\P ar k B at hr oo m

A D

A P ro je ct \D

W G

\R ev it\

-0

5_

M o n tg om er y P a rk

_A

IS

.r vt

5835-005

G-004

M O

N

TG

O M

ER

Y

PA

R

K B

A

TH

R O

O M

A D

A

IN

TE

R

IO

R

IM

PR

O

VE

M

EN

TS

1S T

ST

, M

O N

TG

O

M

ER

Y, P

A

10-19-2026

A C

C

ES

SI

B

IL

IT

Y D

IA

G

R A

M S

IS

SU

ED

F

O R

B

ID

D

IN

G

M O

N

TG

O M

ER

Y

B O

R O

U G

H

S M

AI

N

S

TR

EE

T

M O

N

TG

O M

ER

Y, P A

0-

-2

IS

S U

E D

F O

R B

ID

D

TACTILE SIGNAGE AND SYMBOLS

LETTERS AND NUMBERS:

1. LETTERS AND NUMERALS MUST BE RAISED 1/32" (0.8 MM) MINIMUM, UPPERCASE,

SANS-SERIF OR SIMPLE SERIF AND MUST BE ACCOMPANIED WITH GRADE 2 BRAILLE.

RAISED CHARACTERS MUST BE AT LEAST 5/8" (16 MM) HEIGHT, BUT NO HIGHER THAN

2" (50 MM). PICTOGRAMS MUST BE ACCOMPANIED BY THE EQUIVALENT VERBAL

DESCRIPTION PLACES DIRECTLY BELOW THE PICTOGRAM. THE BORDER

DIMENSIONS OF THE PICTOGRAM MUST BE 6" (152 MM) MINIMUM IN HEIGHT. (ADAAG

SEC. 4.30.4)

2. LETTERS AND NUMBERS ON SIGNS MUST HAVE A WIDTH-TO-HEIGHT RATIO BETWEEN

3:5 AND 1:1 AND A STROKE WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND 1:10. (ADAAG

SEC. 4.30.2)

3. THE CHARACTERS AND BACKGROUND OF SIGNS MUST BE EGGSHELL, MATTE, OR

OTHER NON-GLARE FINISH. CHARACTERS AND SYMBOLS MUST CONTRAST WITH

THEIR BACKGROUND - EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR

DARK CHARACTERS ON A LIGHT BACKGROUND. (ADAAG SEC. 4.30.5)

4. CHARACTERS AND NUMBERS ON SIGNS MUST BE SIZED ACCORDING TO THE

VIEWING DISTANCE FROM WHICH THEY ARE TO BE READ. THE MINIMUM HEIGHT IS

MEASURED USING AN UPPER CASE X. LOWER CASE CHARACTERS ARE PERMITTED.

(ADAAG SEC. 4.30.3)

5. BRAILLE MUST BE CONTRACTED (GRADE 2) BRAILLE AND MUST COMPLY WITH

SECTION 703.4. (ICC/ANSI SCE. 703.4.1)

6. BRAILLE MUST BE BELOW THE CORRESPONDING TEXT. IF TEXT IS MULTILINED,

BRAILLE MUST BE PLACED BELOW THE ENTIRE TEXT. BRAILLE MUST BE SEPARATED

3/8" (9.5 MM) MIN FROM ANY OTHER TACTILE CHARACTERS AND 3/8" (9.5 MM) MIN

FROM RAISED BORDERS AND DECORATIVE ELEMENTS. BRAILLE PROVIDED ON

ELEVATOR CAR CONTROLS MUST BE SEPARATED 3/16" (4.8 MM) MIN EITHER

DIRECTLY BELOW OR ADJACENT TO THE CORRESPONDING RAISED CHARACTERS OR

SYMBOLS. (ICC/ANSI SEC. 703.4.4)

SIGN LOCATIONS:

1. ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY PERSONS

WITH DISABILITIES AND AT EVERY MAJOR JUNCTION ALONG OR LEADING TO AN

ACCESSIBLE ROUTE OR TRAVEL MUST BE IDENTIFIED WITH A SIGN DISPLAYING THE

INTERNATIONAL SYMBOL OF ACCESSIBILITY AND WITH ADDITIONAL DIRECTIONAL

SIGNS, AS REQUIRED, TO BE VISIBLE TO PERSONS ALONG APPROACHING

PEDESTRIAN WAYS. (ICC/IBC SEC. 1110)

2. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, SIGNS

MUST BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR.

WHERE THERE IS NO WALL SPACE TO THE LATCH SIDE OF THE DOOR, INCLUDING AT

DOUBLE LEAF DOORS, SIGNS MUST BE PLACED ON THE NEAREST ADJACENT WALL.

MOUNTING HEIGHT MUST BE 60" (1525 MM) ABOVE THE FINISH FLOOR TO THE

CENTERLINE OF THE SIGN MOUNTING LOCATION FOR SUCH SIGNAGE MUST BE SO

THAT A PERSON MAY APPROACH WITHIN 3" (76 MM) OF THE SIGNAGE WITHOUT

ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A

DOOR. (ADAAG SEC. 4.30.6)

3. ADDITIONAL DIRECTIONAL SIGNS ALONG ACCESSIBLE PATH OF TRAVEL ARE

REQUIRED. (ICC/IBC SEC. 1110)

4. BUILDINGS REMODELED TO PROVIDE ACCESSIBLE SANITARY FACILITIES FOR PUBLIC

USE MUST HAVE INFORMATION POSTED IN THE LOBBY AS PART OF THE BUILDING

DIRECTORY.

INTERNATIONAL SYMBOL OF ACCESSIBILITY:

1. STANDARD USED TO IDENTIFY ACCESSIBLE FACILITIES.

2. WHITE FIGURE ON BLUE BACKGROUND, COLOR: #15090, ON FEDERAL STANDARD #

595A.

3. WHEN ENFORCING AGENCY DETERMINES, IF APPROPRIATE, SPECIAL DESIGNS AND

COLORS MAY BE APPROVED.

BRAILLE:

1. DOTS TO BE 0.09" (2.2 MM) TO 0.1" (2.5 MM) ON CENTER IN EACH CELL.

2. 0.241" (6.1 MM) TO 0.3" (7.6 MM) SPACE BETWEEN CELLS HORIZONTALLY.

3. 0.395" (10 MM) TO 0.4" (10.2 MM) SPACE BETWEEN CELLS VERTICALLY.

4. DOTS RAISED 0.025" (0.6 MM) TO 0.037" (0.9 MM) ABOVE BACKGROUND.

5. DOTS BASE DIAMETER TO BE 0.059" (1.5 MM) TO 0.063" (1.6 MM).

PROVIDE TACTILE SIGNAGE AS

PER ANSI CODE SECTION 703

EQEQ

CLEAR

18" MIN

C

LE

AR

" M

IN

EQEQ

" M

IN

" M

AX

DOOR LATCH SIDE

TACTILE SIGNAGE MOUNTING HEIGHTS

INTERNATIONAL SYMBOLS FOR ACCESSIBILITY

RAISED

1/

GENERAL RESTROOM SIGNAGE

MEN WOMEN

INTERNATIONAL

TDD SYMBOL

INTERNATIONAL

SYMBOL OF

ACCESS FOR

HEARING IMPAIRED

PROPORTIONS FOR

INTERNATIONAL

SYMBOLS FOR

ACCESSIBILITY

DOORWAYS

Z

CLEAR

32" MIN YX

REQUIRED CLEAR

SPACE PUSH SIDE

FRONT APPROACH

* 12" WITH BOTH

CLOSER AND LATCH

X= 48" MIN

Y= 0" *

LATCH APPROACH

* 48" MIN WITH BOTH

CLOSER AND LATCH

X= 42" MIN *

Y= 24" MIN

HINGE APPROACH

* 48" MIN WITH BOTH

CLOSER AND LATCH

** 12" MIN WITH BOTH

CLOSER AND LATCH

X= 42" MIN *

Y= 0" **

Z= 22" MIN

PUSH SIDE DOOR

CLEARANCE PLAN

REQUIRED CLEAR

SPACE PULL SIDE

LATCH APPROACH

* 54" MIN WITH BOTH

CLOSER AND LATCH

X= 48" MIN *

Y= 24" MIN

HINGE APPROACH

X= 60" MIN

Y= 36" MIN

X= 54" MIN

Y= 42" MIN

OR X

Y

FRONT APPROACH

X= 60" MIN

Y= 18" MIN

PULL SIDE DOOR

CLEARANCE PLAN

18" MIN INTERIOR

24" MIN EXTERIOR &

" M

IN

60" MIN

RAMP LANDING AT

DOORWAY PLAN

32" CLEAR 24" MIN EXT

18" MIN INT

60" MIN

" M

IN

VESTIBULE PLAN TWO DOORS IN SERIES

" M

IN

NOTES:

1. CLEAR SPACES MUST BE LEVEL TO PREVENT WHEELCHAIRS FROM

ROLLING WHEN THE OCCUPANT RELEASES THE WHEEL GRIPS TO REACH

FOR THE DOOR. 1/4" PER FOOT IS ALLOWED FOR DRAINAGE.

2. WHERE DOORS OPEN ONTO, BUT NOT INTO, A CORRIDOR THE REQUIRED

LEVEL AREA BEYOND THE DOORS MAY BE A MINIMUM OF 48"

RESTROOMS

N O

TE

N O

T

AL

L

AC

C

ES

SA

BL

E C

O M

PO

N

EN

TS

M

AY

B E

U

SE

D

IN

T H

IS

P

R O

JE

C

T.

T

H

IS

S H

EE

T

IS

P

R O

VI

D

ED

F

O R

G

EN

ER

AL

R

EF

ER

EN

C E

O N

LY

Project No.:

Sheet No.:

M

AR

K D

AT

E

C O

M M

EN

TS

Date:

A

3000 WESTINGHOUSE DRIVE

SUITE 400

CRANBERRY TWP, PA 16066

(877) 323-6603

© Larson Design Group 2026

2 3 4 5 6 7 8 9 10

B

C

D

E

F

G

SEAL

Larson Design Group

/1 9/

9:

:0

A

M P

:\5

5\

5-

\P ar k B at hr oo m

A D

A P ro je ct \D

W G

\R ev it\

-0

5_

M o n tg om er y P a rk

_A

IS

.r vt

5835-005

G-005

M O

N

TG

O M

ER

Y

PA

R

K B

A

TH

R O

O M

A D

A

IN

TE

R

IO

R

IM

PR

O

VE

M

EN

TS

1S T

ST

, M

O N

TG

O

M

ER

Y, P

A

10-19-2026

A C

C

ES

SI

B

IL

IT

Y D

IA

G

R A

M S

IS

SU

ED

F

O R

B

ID

D

IN

G

M O

N

TG

O M

ER

Y

B O

R O

U G

H

S M

AI

N

S

TR

EE

T

M O

N

TG

O M

ER

Y, P A

0-

-2

IS

S U

E D

F O

R B

ID

D

CONCRETE BLOCK

SECTIONS/ SECTIONAL DETAILS

CAST-IN-PLACE-CONCRETE

STRUCTURAL/MISCELLANEOUS

STEEL

EARTH

GRAVEL/ENGINEERED

FILL

STONE, OR NATURAL

BUILDING STONE

PLASTER OR GYPSUM BOARD,

OR EXTERIOR SHEATHING

BATT INSULATION

ROOF, TAPERED, CAVITY OR

RIGID INSULATION

FINISHED WOOD TRIM

PLYWOOD

CAVITY DRAINAGE MATERIAL

N

PLAN

NORTH

1i

Room name

X

1A2.2

W1

NORTH ARROW

SECTION

MARKER

ELEVATION

STAIR TAG

ROOM TAG

KEY TAG(s)

WALL TYPE

WINDOW TYPE

VIEW NAME,

NUMBER AND

SCALE

STAIR TAG

DOOR NUMBER

EXTERIOR ELEVATION

INTERIOR ELEVATION

0 GRID LOCATION

REVISION TAG

A101

SIM

A101

A101

XX

SYMBOLS

KEY NOTE TAGXX.XX

PLANS / PLAN DETAIL GRAPHICS

CONCRETE BLOCK WALLS

CAST-IN-PLACE-

CONCRETE WALLS

STUD WALLS

BRICK WALLS

CONCRETE SLABS AND/OR

CONCRETE SIDEWALKS

EXISTING WALLS

DOOR DESIGNATIONS

EXISTING DOOR AND/OR FRAME TO

REMAIN - SEE DOOR SCHEDULE FOR ANY

ADDITIONAL WORK

NEW DOOR AND/OR FRAME TO BE

PROVIDED - SEE DOOR SCHEDULE

GENERAL NOTES

1. CONTRACTORS MUST NOT SCALE THESE DRAWINGS

FOR CONSTRUCTION PURPOSES. IN THE EVENT OF

OMISSION OF NECESSARY DIMENSIONS OR

INFORMATION, CONTRACTOR MUST NOTIFY

ARCHITECT/ENGINEER. DETAILED DRAWINGS AND

LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER

SMALLER SCALE DRAWINGS.

2. CONTRACTOR SHALL VERIFY ALL COLUMN

COORDINATES AND CHECK THEM AGAINST DIMENSIONS

SHOWN ON PLANS AND DETAILS. NOTIFY ARCHITECT OF

ANY DISCREPANCY DURING STAKING.

3. ALL FINISHED FLOOR ELEVATIONS RE: TO

ARCHITECTURAL DRAWINGS ONLY. RE: CIVIL DRAWINGS

FOR RELATIONSHIP TO PROJECT BENCHMARK(S).

4. VERIFY ALL DIMENSIONS, CONDITIONS, AND GRADES AT

JOB SITE. ALL CONTRACTORS MUST COORDINATE THEIR

WORK WITH OTHER TRADES AND REPORT

DISCREPANCIES, PRIOR TO THEIR CONSTRUCTION, TO

THE ARCHITECT FOR REVIEW AND CLARIFICATION OR

ACTION.

5. VERIFY SIZE, LOCATIONS CHARACTERISTICS AND

INSTALLATION REQUIREMENTS OF ALL EQUIPMENT TO

BE FURNISHED WITH MANUFACTURERS OR SUPPLIERS

BEFORE BEGINNING CONSTRUCTION.

6. VERIFY SIZE AND LOCATION OF ALL OPENINGS FOR

MECHANICAL AND ELECTRICAL EQUIPMENT AND

RELATED WORK WITH CONTRACTORS INVOLVED AND

EQUIPMENT TO BE FURNISHED. FOR CONSTRUCTION

DETAILS NOT SHOWN, USE THE MANUFACTURER'S

STANDARD DETAILS OR APPROVED SHOP DRAWINGS /

DATA SHEETS IN ACCORDANCE WITH THE PROJECT

SPECIFICATIONS.

7. VERIFY ALL ELEVATIONS AND DIMENSIONS OF

STRUCTURAL ELEMENTS WITH ARCHITECTURAL

DRAWINGS. IN CASE OF CONFLICT, NOTIFY

ARCHITECT/ENGINEER. THE CONTRACTORS MUST

VERIFY ALL DIMENSIONS AND BE RESPONSIBLE FOR

THEM. ALL DIMENSIONAL DISCREPANCIES ARE TO BE

BROUGHT TO THE ATTENTION OF THE

ARCHITECT/ENGINEER.

8. ADD SUFFICIENT BLOCKING IN STUD WALLS TO

SUPPORT ALL ITEMS OR EQUIPMENT SHOWN OR

SPECIFIED TO BE ATTACHED TO THE WALLS. PROVIDE

ADDITIONAL STRUCTURAL SUPPORT (ANGLES,

CHANNELS, ETC.) WITHIN WALLS WHERE THE WEIGHT OF

ATTACHED ITEMS OR EQUIPMENT IS TOO GREAT TO BE

SUPPORTED BY METAL STUDS. PROVIDE BLOCKING FOR

OWNER FURNISHED AND/ OR INSTALLED ITEMS, IF ANY.

9. ALL INTERIOR DIMENSIONS TO FACE OF STUD, FACE OF

MASONRY, CENTERLINE OF COLUMN, OR EDGE OF SLAB

UNLESS NOTED OTHERWISE.

10. ALL MATERIALS ARE TO BE INSTALLED IN ACCORDANCE

WITH MANUFACTURER BEST PRACTICE

RECOMMENDATIONS UNLESS NOTED OTHERWISE.

11. THE ARCHITECTURAL FLOOR PLANS, REFLECTED

CEILING PLANS, SECTIONS, AND ELEVATIONS SHOW THE

EXACT LOCATION OF MANY, BUT NOT ALL, EXPOSED

PARTS OF THE WORK. FOR TYPICAL DIMENSIONING

CONVENTIONS, INCLUDING RULES FOR LOCATING

DOORS AND OTHER ITEMS WHICH HAVE NOT BEEN

DIMENSIONED OR LOCATED EXACTLY, APPLY THE RULES

INDICATED BY THE "GENERAL CONVENTIONS" SHEET TO

DETERMINE THE EXACT LOCATION OF EACH EXPOSED

PART OF THE WORK.

12. 3/4" FIRE-RETARDANT TREATED PLYWOOD BACKING 8'-0"

HIGH SHALL BE PROVIDED AND INSTALLED ON ALL

WALLS OF TELEPHONE AND ELECTRICAL ROOMS AS

REQUIRED UNLESS SPECIFICALLY SHOWN OTHERWISE

ON ELECTRICAL DRAWINGS.

13. PROVIDE AND INSTALL ACCESS PANELS, WHERE

REQUIRED BY BUILDING CODE OR FOR THE PROPER

OPERATION OF MECHANICAL OR ELECTRICAL

EQUIPMENT, AND AS SHOWN ON THE DRAWINGS.

CONTRACTOR SHALL COORDINATE SIZE, LOCATION, AND

TYPE OF ACCESS PANEL WITH OTHER CONTRACTORS'

WORK AND RECEIVE APPROVAL OF THE ARCHITECT.

ACCESS PANEL SHALL BE AS SPECIFIED.

14. ALL METAL STUDS WALLS WHERE PLUMBING OCCURS

OR STRUCTURAL COLUMNS ARE LOCATED WITH SHALL

BE MINIMUM 6" METAL STUDS. NOTIFY ARCHITECT OF

ANY DISCREPANCIES OR CONFLICTS.

15. SIZES OF HOUSEKEEPING PADS AND BASES FOR

MECHANICAL EQUIPMENT ARE APPROXIMATE.

CONTRACTOR SHALL VERIFY EXACT LOCATION AND

REQUIRED SIZE OF ALL CONCRETE PADS AND BASES

WITH EQUIPMENT MANUFACTURERS BEFORE POURING.

ALL PADS TO BE PROVIDED BY THE CONTRACTOR.

DEMOLITION LEGEND

EXISTING WINDOW AND/OR FRAME TO BE

REMOVED - SEE DEMO PLAN/NOTES

EXISTING DOOR AND/OR FRAME TO BE

REMOVED - SEE DEMO PLAN/NOTES

EXISTING WALL TO BE REMOVED - SEE

DEMO PLAN/NOTES

Project No.:

Sheet No.:

M

AR

K D

AT

E

C O

M M

EN

TS

Date:

A

3000 WESTINGHOUSE DRIVE

SUITE 400

CRANBERRY TWP, PA 16066

(877) 323-6603

© Larson Design Group 2026

2 3 4 5 6 7 8 9 10

B

C

D

E

F

G

SEAL

Larson Design Group

/1 9/

9:

:0

A

M P

:\5

5\

5-

\P ar k B at hr oo m

A D

A P ro je ct \D

W G

\R ev it\

-0

5_

M o n tg om er y P a rk

_A

IS

.r vt

5835-005

A-001

M O

N

TG

O M

ER

Y

PA

R

K B

A

TH

R O

O M

A D

A

IN

TE

R

IO

R

IM

PR

O

VE

M

EN

TS

1S T

ST

, M

O N

TG

O

M

ER

Y, P

A

10-19-2026

G

EN

ER

A

L N

O

TE

S, S

YM

B

O

LS

IS

SU

ED

F

O R

B

ID

D

IN

G

M O

N

TG

O M

ER

Y

B O

R O

U G

H

S M

AI

N

S

TR

EE

T

M O

N

TG

O M

ER

Y, P A

12" = 1'-0"

NAME

0-

-2

IS

S U

E D

F O

R B

ID

D

DEMOLISH AND REMOVE EXISTING CMU

PARTITION WALLS AND STALL DOORS,

INCLUDING ALL ASSOCIATED

COMPONENTS (TYP.).

EXISTING WINDOWS

TO BE REMOVED AND REPLACED (TYP.).

REMOVE EXISTING DOOR AND

FRAME. SAVE FOR REINSTALL

REMOVE EXISTING DOOR AND

FRAME. SAVE FOR REINSTALL

PLAN NOTES - DEMOLITION PLAN

A. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE

MANNER AND IN STRICT ACCORDANCE WITH OSHA

REGULATIONS.

B. THE CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF

DEMOLITION. THE WORK INCLUDES, BUT IS NOT LIMITED

TO, THE DEMOLITION AND REMOVAL OF WALLS, DOORS,

PLUMBING, PAVING, MECHANICAL AND ELECTRICAL

ITEMS INCLUDING CONDUITS AND DUCTWORK AS

SHOWN ON DRAWINGS OR AS REQUIRED FOR THE

INSTALLATION OF THE NEW WORK FOR A COMPLETE

JOB.

C. WHEN UTILITIES ARE REMOVED, CAP AND SEAL A

MINIMUM OF 8" BELOW FINISH FLOOR OR BACK TO

PRIMARY RUNS WHEN ABOVE SLAB. ALL UNUSED

SUPPORTS, HANGERS, AND ACCESSORIES ARE TO BE

REMOVED.

D. WHEN REMOVING EXISTING STRUCTURAL ITEMS, IT IS

THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE

ADEQUATE SHORING, BRACING, AND SUPPORT SYSTEMS

TO KEEP THE EXISTING STRUCTURE INTACT AND IN

SAFE CONDITION.

E. NOTES INDICATING DEMOLITION WORK ARE NOT

CONFINED SOLELY TO THE DEMOLITION PLANS. THE

GENERAL CONTRACTOR SHALL REVIEW ALL

CONSTRUCTION DOCUMENTS, INCLUSIVE OF

SCHEDULES AND SPECIFICATIONS, TO DETERMINE FULL

EXTENT OF DEMOLITION SCOPE OF WORK.

F. CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL

EXISTING BUILDING MATERIALS TO REMAIN AT ALL

TIMES.

G. PREP AND PATCH AREAS OF DEMOLITION TO RECEIVE

NEW CONSTRUCTION OR COATINGS.

H. REFER TO MEP SHEETS FOR ADDITIONAL DEMOLITION

INFORMATION NOT SHOWN.

I. STORE AND PROTECT ALL EXISTING HAND HELD

EXTINGUISHERS, INVENTORIED AND REPORTED TO

OWNER. AT OWNER'S OPTION THE CONTRACTOR IS TO

EITHER TURN OVER THE EXISTING EXTINGUISHER FOR

OWNER'S USE OR DISPOSE OF THEM AS PART OF THE

DEMOLITION SCOPE.

J. AT ALL LOCATIONS OF SURFACE MOUNTED ELECTRICAL

ITEMS, CONTRACTOR IS TO REMOVE AND DISPOSE OF

ALL J-BOXES, BACK BOXES, CONDUITS, STRAPS,

HANGERS, AND ALL ASSOCIATED ITEMS.

K. REFER TO FLOOR PLANS, EXTERIOR ELEVATIONS, AND

SITE PLAN FOR ADDITIONAL INFORMATION OF ITEMS

THAT MAY BE LOCATED ON OPPOSITE SIDE OF WALLS

TO BE DEMOLISHED. CONTRACTOR TO EXERCISE

CAUTION AND AWARENESS AT ALL TIMES OF

DEMOLITION SCOPE.

L. CONTRACTOR TO ENSURE EXISTING PARK BUILDING

ATTACHED TO THE BATHROOMS REMAINS FUNCTIONAL

DURING CONSTRUCTION.

M. AN ATTEMPT HAS BEEN MADE TO SHOW ON THE

DRAWINGS EXISTING BUILDING CONSTRUCTION AND

CONDITIONS, HOWEVER, THE CONTRACTOR SHALL BE

RESPONSIBLE FOR INSPECTING AND VERIFYING ALL

EXISTING CONDITIONS PRIOR TO THE START OF

CONSTRUCTION, AND SHALL REPORT ANY

DISCREPANCIES TO THE ENGINEER FOR CLARIFICATION

BEFORE PROCEEDING WITH THE WORK.

N. ANY DEMOLITION IN ADDITION TO WHAT IS REFERENCED

ON THE DRAWINGS SHALL BE APPROVED BY ARCHITECT

PRIOR TO BEGINNING. ANY ADDITIONAL DEMOLITION

REQUIRED AS A CONVENIENCE TO THE CONTRACTOR

SHALL BE AT THE CONTRACTOR’S EXPENSE AND SHALL

BE REPLACED AT THE CONTRACTOR’S EXPENSE.

N

Project No.:

Sheet No.:

M

AR

K D

AT

E

C O

M M

EN

TS

Date:

A

3000 WESTINGHOUSE DRIVE

SUITE 400

CRANBERRY TWP, PA 16066

(877) 323-6603

© Larson Design Group 2026

2 3 4 5 6 7 8 9 10

B

C

D

E

F

G

SEAL

Larson Design Group

/1 9/

9:

:0

A

M P

:\5

5\

5-

\P ar k B at hr oo m

A D

A P ro je ct \D

W G

\R ev it\

-0

5_

M o n tg om er y P a rk

_A

IS

.r vt

5835-005

AD101

M O

N

TG

O M

ER

Y

PA

R

K B

A

TH

R O

O M

A D

A

IN

TE

R

IO

R

IM

PR

O

VE

M

EN

TS

1S T

ST

, M

O N

TG

O

M

ER

Y, P

A

10-19-2026

A R

C H

IT

EC

TU

R

A L

D

EM

O

LI

TI

O

N P

LA

N

IS

SU

ED

F

O R

B

ID

D

IN

G

M O

N

TG

O M

ER

Y

B O

R O

U G

H

S M

AI

N

S

TR

EE

T

M O

N

TG

O M

ER

Y, P A

3/4" = 1'-0"A1 ARCHITECTURAL - RESTROOM DEMOLITION PLAN

SCALE:

1' - 0" 2' - 0" 4' - 0"

3/4" = 1' - 0"

0-

-2

IS

S U

E D

F O

R B

ID

D

NEW 24" X 36" FIXED VINYL WINDOW WITH

WINDOW PROTECTION ON INTERIOR AND

EXTERIOR (TYP.).

REFER TO DIVISION 08 - OPENINGS.

REFERENCE PLUMBING

DRAWINGS FOR

MOUNTING HEIGHTS

RELOCATED DOOR

AND FRAME.

RELOCATED DOOR

AND FRAME.

PLAN NOTES - FLOOR PLAN

1. ALL DIMENSIONS ON PLAN FOR NEW INTERIOR WALL

LAYOUTS ARE FROM FACE OF STUD, FACE OF MASONRY,

CENTERLINE OF COLUMN OR EDGE OF SLAB, U.N.O..

2. PATCH & FIRESTOP GYP. BD. PARTITIONS AS REQUIRED

BY LOCAL CODES.

3. APPROVED FIRE EXTINGUISHERS MUST BE FURNISHED

AND INSTALLED BY G.C. AS REQUIRED BY LOCAL

AUTHORITY.

4. PROVIDE & INSTALL BROWN PAPER COVERING APPLIED

TO THE STOREFRONT GLAZING DURING FURNISHING.

5. ALL INTERIOR ARTITIONS MUST EXTEND MIN. 6" ABOVE

FINISHED CEILING UNLESS NOTED OTHERWISE.

6. REFER TO BUILDING AND WALL SECTIONS FOR ALL

EXTERIOR WALL CONSTRUCTION.

7. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT

SHOWN WITH THE ARCHITECT PRIOR TO INSTALLATION.

8. DISCONTINUE ALL DRYWALL ON INTERIOR FACE OF

EXTERIOR WALL AT ALL INTERSECTING WALLS, TYP.

9. 3/4" FIRE-RETARDANT TREATED PLYWOOD BACKING 8'-0"

HIGH SHALL BE PROVIDED AND INSTALLED ON ALL

WALLS OF TELEPHONE AND ELECTRICAL ROOMS AS

REQUIRED UNLESS SPECIFICALLY SHOWN OTHERWISE

ON ELECTRICAL DRAWINGS.

3/4" = 1'-0"A1 ARCHITECTURAL - RESTROOM PLAN

N

Project No.:

Sheet No.:

M

AR

K D

AT

E

C O

M M

EN

TS

Date:

A

3000 WESTINGHOUSE DRIVE

SUITE 400

CRANBERRY TWP, PA 16066

(877) 323-6603

© Larson Design Group 2026

2 3 4 5 6 7 8 9 10

B

C

D

E

F

G

SEAL

Larson Design Group

/1 9/

9:

:0

A

M P

:\5

5\

5-

\P ar k B at hr oo m

A D

A P ro je ct \D

W G

\R ev it\

-0

5_

M o n tg om er y P a rk

_A

IS

.r vt

5835-005

A-101

M O

N

TG

O M

ER

Y

PA

R

K B

A

TH

R O

O M

A D

A

IN

TE

R

IO

R

IM

PR

O

VE

M

EN

TS

1S T

ST

, M

O N

TG

O

M

ER

Y, P

A

10-19-2026

A R

C H

IT

EC

TU

R

A L

FL

O

O R

P

LA

N

IS

SU

ED

F

O R

B

ID

D

IN

G

M O

N

TG

O M

ER

Y

B O

R O

U G

H

S M

AI

N

S

TR

EE

T

M O

N

TG

O M

ER

Y, P A

KEY NOTES

1. AREA OF PARTIALLY REMOVED WALL BACKING WITH

EXPOSED FRAMING. PATCH AND RESTORE WALL WITH

MOSITURE-RESISTANT GYPSUM BOARD AND FINISHES

TO MATCH ADJACENT SURFACES.

2. CONTRACTOR SHALL PREPARE ALL EXISTING WALLS,

CEILINGS, AND CONDUIT TO RECEIVE NEW FINISHES.

PREPARATION SHALL INCLUDE CLEANING, PATCHING,

REPAIRING OF CRACKS AND DEFECTS AND REMOVAL

OF DETERIORATED MATERIALS. PROVIDE PRIMER AND

FINISH COATS IN ACCORDANCE WITH SPECIFICATIONS,

REFER TO DIVISION 09 - PAINTINGS/COATINGS. ALL

PAINTED SURFACES SHALL RECEIVE A UNIFORM,

SINGLE COLOR AS SELECTED BY OWNER.

3. CONTRACTOR SHALL PREPARE EXISTING FLOORS TO

RECEIVE NEW EXPOXY, NON-SLIP FLOOR COATING

SYSTEM. PREPARATION SHALL INCLUDE CLEANING,

REPAIRING OF CRACKS AND SPALLS, AND REMOVAL OF

DETERIORATED MATERIALS. APPLY EPOXY COATING

SYSTEM IN ACCORDANCE WITH MANUFACTURERS

RECOMMENDATIONS, REFER TO DIVISION 09 -

PAINTINGS/COATINGS.

4. PROVIDE NEW 24" X 18" LOUVER IN EXTERIOR DOOR.

5. PROVIDE NEW 14" 'WHIRLYBIRD' INTERNALLY BRACED

ALUMINUM WIND TURBINE. CUT NEW TURBINE INTO

EXISTING ROOFING TO REMAIN AND PROVIDE NEW

FLASHING/STORM COLLAR WITH LOWER HALF OF

FLASHING EXTENDING OVER THE EXISTING ROOFING

AND UPPER HALF OF FLASHING EXTENDING UNDER THE

EXISTING ROOFING. PROVIDE ADDITIONAL

BLOCKING/BRACING AT EXISTING ROOF STRUCTURE AS

REQUIRED FOR PROPER INSTALLATION OF NEW

TURBINE.

SCALE:

1' - 0" 2' - 0" 4' - 0"

3/4" = 1' - 0"

0-

-2

IS

S U

E D

F O

R B

ID

D

OS

DL

LC

J

J

F1

DO

M

OS

TC

J

FB

PC

SPD

ELECTRICAL DEVICE TAGS: UPPERCASE LETTER(S) INDICATES

PANEL ID AND CIRCUIT NUMBER. LOWERCASE LETTER INDICATES

DESIGNATION OF CONTROLLING SWITCH (WHERE APPLICABLE).

SWITCH ID INDICATED BY A LOWERCASE LETTER. SWITCH IDS ARE UNIQUE PER

SPACE. A SWITCH WITH AN ID "A" CONTROLS ALL DEVICES WITHIN THE SPACE IN

WHICH IT IS LOCATED TAGGED WITH "A". A SWITCH WITHOUT A TAGGED ID

CONTROLS ALL LIGHTING FIXTURES WITHIN A SPACE. ID TAGS MAY BE USED ON

CONTROL DEVICES OTHER THAN SWITCHES, SUCH AS OCCUPANCY SENSORS

OR CONTACTORS.

EQUIPMENT TAGS: EQUIPMENT ID IS INDICATED BY AN UNDERLINED

TAG ADJACENT TO THE EQUIPMENT. SEE THE EQUIPMENT

CONNECTION SCHEDULE FOR DESCRIPTION, ELECTRICAL

REQUIREMENTS, AND PANEL AND CIRCUIT NUMBER.

SYMBOLS/GRAPHIC APPEARANCE OF EQUIPMENT VARIES.

SOLID, ARCED LINES CONNECTING EQUIPMENT, DEVICES, OR FIXTURES

INDICATE UNSWITCHED POWER CIRCUITING. WIRES ARE ONLY

INTENDED TO INDICATE TO WHAT CIRCUIT DEVICES ARE CONNECTED.

ACTUAL CONNECTIONS, CIRCUIT ROUTING, INSTALLTION, JUNCTION

BOXES, ETC. SHALL BE FIELD-DETERMINED BY THE CONTRACTOR.

HOME RUN TO BRANCH CIRCUIT PANELBOARD. THE EQUIPMENT

NAME AND CIRCUIT NUMBER(S) ARE INDICATED, SEPARATED BY A

HYPHEN. HOMERUNS ARE ONLY INTENDED TO INDICATE PANEL

AND CIRCUIT NUMBER. ACTUAL HOMERUN LOCATION SHALL BE

FIELD-DETERMINED BY THE CONTRACTOR.

POWER SYMBOLS

ELECTRICAL SYMBOL LEGEND

ROOM

EXIT LIGHT, WALL-MOUNTED. SHADING AND ARROWS INDICATE FACES

AND DIRECTIONAL CHEVRONS.

WALL-MOUNTED FIXTURES, TYPICAL (VARIOUS SYMBOLS)

EMERGENCY LIGHTING UNIT, WALL-MOUNTED, REMOTE BATTERY

EMERGENCY LIGHTING UNIT, WALL-MOUNTED, INTEGRAL BATTERY

EMERGENCY LIGHTING UNIT, CEILING-MOUNTED, INTEGRAL BATTERY

EMERGENCY LIGHTING UNIT, CEILING-MOUNTED, REMOTE BATTERY

LIGHTING FIXTURES, TYPICAL, RECTANGULAR(VARIOUS SYMBOLS)

OUTER DOTS INDICATE SUSPENDED.

LIGHTING FIXTURES, TYPICAL, ROUND (VARIOUS SYMBOLS)

CENTER DOT INDICATES PENDANT.

DIAGONAL LINE INDICATES DOWNLIGHT.

CHEVRON INDICATES WALL WASH.

DIRECTIONAL LIGHT, TRACK LIGHT, FLOOD LIGHT

EXIT LIGHT, CEILING-MOUNTED. SHADING AND ARROWS INDICATE

FACES AND DIRECTIONAL CHEVRONS.

LINEAR LIGHT

EXIT LIGHT/EMERGENCY LIGHTING UNIT COMBO

DIAGONAL HATCH INDICATES LIGHT ON A CRITICAL CIRCUIT.

DIAGONAL HATCH INDICATES LIGHT ON AN EMERGENCY OR LIFE SAFETY

CIRCUIT.

EXTERIOR AREA LIGHT AND POLE.

EXTERIOR POST-TOP AREA LIGHT AND POLE.

BOLLARD LIGHT

SINGLE- SWITCH

FOUR-WAY SWITCH

SWITCH MODIFIERS:

K: KEYED

D: DIMMING

T: TIMER

P: PILOT

OS: OCCUPANCY SENSOR

OSD: OCCUPANCY SENSOR DIMMER

VS: VACANCY SENSOR

AC: ABOVE-COUNTER

LV: LOW-VOLTAGE

LIGHTING CONTACTOR

LIGHTING CONTROL STATION

OCCUPANCY SENSOR

DAYLIGHT HARVESTING SENSOR

SIMPLEX RECEPTACLE

DUPLEX RECEPTACLE

QUADRUPLEX RECEPTACLE

SPECIAL RECEPTACLE, TYPE AS INDICATED

W

AL

L C

EI

LI

N G

FL

O

O

R RECEPTACLE MODIFIERS:

##": HEIGHT AFF ON CENTER

AC: ABOVE COUNTER

GFCI: GROUND-FAULT CIRCUIT INTERRUPTER

WP: WEATHERPROOF IN-USE COVER

TR: TAMPER RESISTANT

HALF SHADING INDICATES SPLIT (TYPICALLY SWITCHED)

OUTSIDE SHADING INDICATES EMERGENCY CIRCUIT

CENTER SHADING INDICATES ISOLATED GROUND

CORD REEL, DEVICE VARIES

DROP CORD, DEVICE VARIES

JUNCTION BOX

FLOOR BOX

EMERGENCY POWER OFF

DOOR OPENER PUSH PLATE

POWER METER

SAFETY SWITCH, FUSED

SAFETY SWITCH, UNFUSED

MOTOR STARTER

COMBINATION STARTER/DISCONNECT

GROUND ROD

GROUND ROD WITH TEST WELL

LIGHTNING PROTECTION AIR TERMINAL

LIGHTNING PROTECTION CONDUCTOR SPLICE

STATIC GROUND RECEPTACLE

LIGHTING SYMBOLS

CONTACTOR

TOGGLE SWITCH

SWITCH MODIFIERS:

M: MOTOR-RATED

MS: MANUAL MOTOR STARTER

GROUNDING AND LIGHTNING PROTECTION SYMBOLS

a EQUIPMENT IS TAGGED WITH PANEL NAME AND WITH PANEL ID IN PARENTHESES.

PANEL ID IS INTENDED AS A DESIGN DOCUMENTATION AID ONLY. DO NOT

INCLUDE PANEL ID IN FIELD-APPLIED CIRCUIT DIRECTORIES OR LABELS.

HATCHED FILL INDICATES DISTRIBUTION PANEL OR SWITCHBOARD.

SOLID FILL INDICATES BRANCH PANEL OR LOAD CENTER.

DASHED BOX INDICATES CODE-REQUIRED CLEARANCE (WIDTH AND DEPTH).

DOOR INDICATES FRONT OF RECESSED PANEL.

PANELBOARDS ARE ASSIGNED AN ABBREVIATED INDICATOR (OR PANEL ID)

FOR USE WITH CIRCUIT NUMBERS. PANEL ID IS LISTED WITHIN THE PANEL

SCHEDULE AND IN THE PANEL ABBREVIATION SCHEDULE.

POWER DISTRIBUTION EQUIPMENT

H P1

A( B)

LP

1A

(C

M D

P( A)

SB1(S)

DEVICES AND FIXTURES ARE TAGGED WITH PANEL ID AND CIRCUIT NUMBER.

FOR EXAMPLE, A DEVICE TAGGED WITH "A1" INDICATES THE DEVICE IS

CIRCUITED TO PANEL DESIGNATED "A," CIRCUIT NUMBER 1. THE PANEL

SCHEDULE CIRCUIT NUMBER CONTANS BOTH THE PANEL ABBREVIATION AND

THE CIRCUIT NUMBER.

XX-1

TRANSFORMER: SEE SINGLE-LINE DIAGRAM FOR DESCRIPTION AND

REQUIREMENTS.

DASHED, ARCED LINES CONNECTING EQUIPMENT, DEVICES, OR

FIXTURES INDICATE SWITCHED POWER.

ABSENCE OF A SWITCH DESIGNATION ON A LIGHTING FIXTURE INDICATES

FIXTURE IS CONTROLLED BY THE ONLY SWITCH IN THE SPACE. AN "X" IN

PLACE OF THE SWITCH DESIGNATION INDICATES UNSWITCHED.

LOWERCASE LETTER: SWITCH ID

LIGHTING TAGS

TOP VALUE: FIXTURE TYPE

ID (UNDERLINED)

BOTTOM VALUE, NUMBER(S): CIRCUIT NUMBER

a a

C1a

WIRING

POWER DEVICE AND EQUIPMENT TAGS

CONSTRUCTION PHASING

EXISTING TO BE DEMOLISHED

NEW

(TYPICAL ALL SYMBOLS AND EQUIPMENT)

ROOM NAME / NUMBER

KEYNOTE SYMBOL

CONTINUATION SYMBOL

SHEET NUMBER WHERE DETAIL IS PLACED

DETAIL NUMBER ON SHEET

REVISION

GENERAL PLAN SYMBOLS

AREA NOT IN CONTRACT

SHEET NUMBER WHERE SECTION IS PLACED

SECTION NUMBER ON SHEET

CONSTRUCTION NOTE SYMBOL##

DEMOLITION NOTE SYMBOL##

EXISTING

* NOTE *

ALL GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS IN

THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT

BE USED IN THIS SET OF DRAWINGS.

A,A1a A

AREA BEING DEMOLISHED

TIME CLOCK

JUNCTION BOX

MULTI OUTLET FLOOR BOX

PHOTOCELL

SURGE PROTECTION DEVICE

GROUND BAR

XX.XX

ELECTRICAL GENERAL NOTES

1. THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO INSTALL ALL NEW WIRING

CONCEALED (FISHED THRU OPENINGS IN EXISTING BUILDING CONSTRUCTION) IN FINISH

AREAS OF THE BUILDING CONSTRUCTION. THE USE OF EXPOSED SURFACE RACEWAYS

WILL NOT BE PERMITTED UNLESS NOTED OTHERWISE. WHERE BUILDING

CONSTRUCTION MUST BE CUT TO CONCEAL NEW CONDUIT AND WIRING THE

CONTRACTOR SHALL SAW CUT A CHANNEL IN BUILDING CONSTRUCTION, INSTALL NEW

CONDUIT AND PATCH AND FINISH DISTURBED AREAS TO MATCH ADJACENT SURFACES

AS APPROVED BY THE ARCHITECT.

2. ALL ELECTRICAL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST

NATIONAL ELECTRICAL CODE AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL

CODES.

3. ALL ELECTRICAL WORK, WIRING, CONNECTIONS AND ASSOCIATED EQUIPMENT WITHIN

THE AREA OF WORK SHALL BE AS PER APPLICABLE ARTICLES OF THE NATIONAL

ELECTRICAL CODE. COORDINATE WITH SPECIFICATIONS FOR DEVICE REQUIREMENTS.

4. ALL ELECTRICAL WORK, ELECTRICAL CONTRACTOR RESPONSIBLE TO ARRANGE

INSPECTION OF ELECTRICAL EQUIPMENT, INCLUDING CONDUCTOR TERMINATIONS IN

PANELS, IN A DE-ENERGIZED CONDITION.

5. ELECTRICAL CONTRACTOR RESPONSIBLE TO REVIEW/REPLACE ALL ELECTRICAL WORK

IN SCOPE TO MEET THE CURRENT NEC CODE REQUIREMENTS.

6. FOR SINGLE PHASE CIRCUITS, UNLESS NOTED OTHERWISE, NEW WIRING INDICATED

SHALL BE 2#12,#12GRD IN 3/4" CONDUIT. FOR THREE PHASE CIRCUITS, UNLESS NOTED

OTHERWISE, NEW WIRING INDICATED SHALL BE 3#12,#12GRD IN 3/4" CONDUIT. FOR

CIRCUITS THAT REQUIRE LONG TRAVEL DISTANCES, REFER TO VOLTAGE DROP NOTE

BELOW, ON THIS SHEET.

7. FURNISH AND INSTALL ALL WIRE, CONDUIT, CONNECTORS, OUTLETS BOXES, ETC.

NECESSARY TO ACHIEVE A COMPLETE ELECTRICAL INSTALLATION. WHERE AN

ELECTRICAL DEVICE IS REQUIRED BY CODE BUT NOT SHOWN SHALL BE FURNISHED

AND INSTALLED AS THOUGH FULLY SHOWN AND SPECIFIED.

8. ALL CONDUIT, JUNCTION BOXES, ETC. ABOVE CEILINGS SHALL BE SUPPORTED FROM

THE BUILDING'S STRUCTURAL SYSTEM. LIGHT FIXTURES WHICH ARE INSTALLED IN A

SUSPENDED CEILING SYSTEM MUST ALSO BE MECHANICALLY FASTENED TO THE

BUILDING'S STRUCTURAL SYSTEM.

9. NO CUTTING OF BUILDING CONSTRUCTION SHALL BE DONE WHICH MAY IN ANYWAY

AFFECT THE BUILDING STRUCTURALLY OR ARCHITECTURALLY WITHOUT FIRST

SECURING THE ENGINEER'S CONSENT AND APPROVAL.

10. NO CONDUITS SHALL BE RUN THROUGH OR SUPPORTED FROM DUCTWORK.

11. ALL EXISTING AREAS WHICH ARE DAMAGED BECAUSE OF THE ELECTRICAL WORK

UNDER THIS CONTRACT SHALL BE REPAIRED AND/OR REFINISHED. THE CONTRACTOR

WILL BE RESPONSIBLE FOR ALL CUTTING, PATCHING, PAINTING AND

REMOVING/REPLACING CEILING TILES DAMAGED OR SOILED AS IS NECESSARY.THE

ENTIRE INSTALLATION MUST BE GROUNDED IN COMPLIANCE WITH THE NATIONAL

ELECTRICAL CODE. ALL DEVICES, EQUIPMENT BOXES, ETC. MUST BE CONNECTED TO A

SOLID, INSULATED GREEN, COPPER GROUNDING CONDUCTOR. THIS GROUNDING

CONDUCTOR MUST BE CONTINUOUS WITHOUT SPLICES FROM POINT OF ORIGIN IN

PANELBOARD TO ALL BOXES AND EQUIPMENT ON EACH BRANCH CIRCUIT. VERIFY

GROUNDING VALUES.

12. THE ENTIRE INSTALLATION MUST BE GROUNDED IN COMPLIANCE WITH THE NATIONAL

ELECTRICAL CODE. ALL DEVICES, EQUIPMENT BOXES, ETC. MUST BE CONNECTED TO A

SOLID, INSULATED GREEN, COPPER GROUNDING CONDUCTOR. THIS GROUNDING

CONDUCTOR MUST BE CONTINUOUS WITHOUT SPLICES FROM POINT OF ORIGIN IN

PANELBOARD TO ALL BOXES AND EQUIPMENT ON EACH BRANCH CIRCUIT. VERIFY

GROUNDING VALUES.

13. FIRESTOP ALL NEW AND EXISTING FLOOR SLAB/CEILING AND WALL PENETRATIONS TO

MAINTAIN THE FIRE RATED CONSTRUCTION (REFER TO SPECIFICATIONS).

14. AFTER CONSTRUCTION, ALL UNUSED SPACES IN PANELS INVOLVED IN THE CONTRACT

SHALL BE LABELED AS A 'PROVISIONS', ALL SPARE BREAKERS SHALL BE PLACED IN THE

OFF POSITION AND LABELED AS 'SPARE'.

15. EXISTING REMOVED ELECTRICAL EQUIPMENT, MATERIALS AND OTHER USEFUL

ELECTRICAL ITEMS SHALL REMAIN THE PROPERTY OF THE OWNER AND SHALL BE

TRANSPORTED AND STORED AT THE SITE WHERE DIRECTED BY THE OWNER. THE

OWNER HAS FIRST RIGHT OF REFUSAL OF EXISTING EQUIPMENT AND MATERIALS.

ITEMS NOTED, TO BE RETAINED BY THE OWNER, SHALL REMAIN THE PROPERTY OF THE

OWNER AND SHALL BE STORED AS COMPLETE UNITS WITH ALL ASSOCIATED

ACCESSORIES AND ASSOCIATED EQUIPMENT. THE EQUIPMENT AND MATERIALS SHALL

BE DISCONNECTED AND CAREFULLY REMOVED UNDER THIS CONTRACT AND SHALL BE

TRANSPORTED TO THE STORAGE AREA AS DIRECTED. THE EQUIPMENT SHALL BE

STORED IN A NEAT MANNER, TAGGED AND IDENTIFIED FOR FUTURE USE BY THE

OWNER. REMOVED CONDUIT, WIRING AND OTHER MISCELLANEOUS ELECTRICAL

MATERIALS AND EQUIPMENT NOT TO BE RETAINED BY THE OWNER AND WHICH ARE NO

LONGER REQUIRED AS A PART OF THE NEW SYSTEMS SHALL BECOME THE PROPERTY

OF THE CONTRACTOR AND SHALL BE IMMEDIATELY REMOVED FROM THE SITE.

Project No.:

Sheet No.:

M

AR

K D

AT

E

C O

M M

EN

TS

Date:

A

3000 WESTINGHOUSE DRIVE

SUITE 400

CRANBERRY TWP, PA 16066

(877) 323-6603

© Larson Design Group 2026

2 3 4 5 6 7 8 9 10

B

C

D

E

F

G

SEAL

Larson Design Group

/1 9/

:2 2:

A

M P

:\5

5\

5-

\P ar k B at hr oo m

A D

A P ro je ct \D

W G

\R ev it\

-0

5_

M o n tg om er y P a rk

_M E

P F

.r vt

5835-005

E-001

M O

N

TG

O M

ER

Y

PA

R

K B

A

TH

R O

O M

A D

A

IN

TE

R

IO

R

IM

PR

O

VE

M

EN

TS

1S T

ST

, M

O N

TG

O

M

ER

Y, P

A

10-19-2026

EL

EC

TR

IC

A L

-S

YM

B O

LS

G

EN

ER

A

L N

O

TE

S

IS

SU

ED

F

O R

B

ID

D

IN

G

M O

N

TG

O M

ER

Y

B O

R O

U G

H

S O

U

TH

M

AI

N S

TR

EE

T M

O N

TG

O

M

ER

Y, P

A

0-

-2

IS

S U

E D

F O

R B

ID

D

EXISTING DOME PENDANT LIGHT FIXTURE TO

BE REPLACED WITH PORCELAIN LIGHT SOCKET

(TYP.)

EXISTING PROCELAIN LIGHT

SOCKET TO REMAIN (TYP.)

PLAN NOTES

1. ALL ELECTRICAL WORK SHALL BE INSTALLED IN

ACCORDANCE WITH THE LATEST NATIONAL ELECTRICAL

CODE AND ALL APPLICABLE FEDERAL, STATE, AND

LOCAL CODES.

3/4" = 1'-0"A1 ELECTRICAL DEMO - LIGHTING PLAN

N

Project No.:

Sheet No.:

M

AR

K D

AT

E

C O

M M

EN

TS

Date:

A

3000 WESTINGHOUSE DRIVE

SUITE 400

CRANBERRY TWP, PA 16066

(877) 323-6603

© Larson Design Group 2026

2 3 4 5 6 7 8 9 10

B

C

D

E

F

G

SEAL

Larson Design Group

/1 9/

:2 2:

A

M P

:\5

5\

5-

\P ar k B at hr oo m

A D

A P ro je ct \D

W G

\R ev it\

-0

5_

M o n tg om er y P a rk

_M E

P F

.r vt

5835-005

ED111

M O

N

TG

O M

ER

Y

PA

R

K B

A

TH

R O

O M

A D

A

IN

TE

R

IO

R

IM

PR

O

VE

M

EN

TS

1S T

ST

, M

O N

TG

O

M

ER

Y, P

A

10-19-2026

EL

EC

TR

IC

A L

D

EM

O

LI

G

H

TI

N G

P

LA

N

IS

SU

ED

F

O R

B

ID

D

IN

G

M O

N

TG

O M

ER

Y

B O

R O

U G

H

S O

U

TH

M

AI

N S

TR

EE

T M

O N

TG

O

M

ER

Y, P

A

KEY NOTES

SCALE:

1'-0" 2'-0" 4'-0"

3/4" = 1'-0"

0-

-2

IS

S U

E D

F O

R B

ID

D

NEW PORCELAIN LIGHT SOCKET (TYP.)

EXISTING PROCELAIN LIGHT

SOCKET TO REMAIN (TYP.)

PLAN NOTES

1. ALL ELECTRICAL WORK SHALL BE INSTALLED IN

ACCORDANCE WITH THE LATEST NATIONAL ELECTRICAL

CODE AND ALL APPLICABLE FEDERAL, STATE, AND

LOCAL CODES.

3/4" = 1'-0"

ELECTRICAL LIGHTING PLANA1

N

Project No.:

Sheet No.:

M

AR

K D

AT

E

C O

M M

EN

TS

Date:

A

3000 WESTINGHOUSE DRIVE

SUITE 400

CRANBERRY TWP, PA 16066

(877) 323-6603

© Larson Design Group 2026

2 3 4 5 6 7 8 9 10

B

C

D

E

F

G

SEAL

Larson Design Group

/1 9/

:2 2:

A

M P

:\5

5\

5-

\P ar k B at hr oo m

A D

A P ro je ct \D

W G

\R ev it\

-0

5_

M o n tg om er y P a rk

_M E

P F

.r vt

5835-005

EL111

M O

N

TG

O M

ER

Y

PA

R

K B

A

TH

R O

O M

A D

A

IN

TE

R

IO

R

IM

PR

O

VE

M

EN

TS

1S T

ST

, M

O N

TG

O

M

ER

Y, P

A

10-19-2026

EL

EC

TR

IC

A L

LI

G

H

TI

N G

P

LA

N

IS

SU

ED

F

O R

B

ID

D

IN

G

M O

N

TG

O M

ER

Y

B O

R O

U G

H

S O

U

TH

M

AI

N S

TR

EE

T M

O N

TG

O

M

ER

Y, P

A

KEY NOTES

SCALE:

1'-0" 2'-0" 4'-0"

3/4" = 1'-0"

0-

-2

IS

S U

E D

F O

R B

ID

D

T/P

S

M

S

T/P

EM

TP

W

IR

S

S

CA

CD

CW

F-CW

NPW

S-CW

HW

HW 140°

HW-R

HW-R 140°

GV

GW

G

OV

OW

PD

V

SS

SHWR

SHWS

SD

OSD

PLUMBING SYMBOLS

* NOTE *

ALL GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS IN THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE USED IN THIS SET OF

DRAWINGS.

LP

FLOOR DRAIN

RO

ID

6" SD-1

0" FD-2

3" AD-1

3" FS-1

6" DD-1

3" HD-1

PLUMBING FIXTURE NOTES

FLOOR DRAIN W/ TRAP PRIMER

"P" INDICATES PRIMER CONNECTION

8" SD-12

RAINFALL SURFACE AREA

PIPE ACCESSORY NOTES

FLOOR DRAIN W/ DEEP SEAL TRAP

FLOOR DRAIN W/ INTEGRAL CLEANOUT

2" FD-3P

4" FCO

AREA DRAIN (NO TRAP)

2" CHECK

2" BALANCE

2" CIRC

1" T/V

2" GATE

2" PRV

2" STRAIN

2" QUICK

2" M-CNTRL

2" S/O

TMVTMV-T/P

TMV-EM

PRIMER

2" METER

1 1/2" METER

1" GAS-CNTRL

2" BACKWATER

ALTERNATE CHECK VALVE

1" REG

1" GAS COCK

1" PLUG

DOUBLE CHECK VALVE

REDUCED PRESSURE ZONE

WV

(E)

2"

EXISTING PIPE TO REMAIN

PIPE TO BE DEMOLISHED

ABOVE GROUND PIPING

NOMINAL PIPE SIZE

BELOW GROUND PIPING

PIPE SLOPE (WHEN APPLICABLE)1/8" / 12" SLOPE

CLEANOUT

SWING CHECK

CHECK VALVE

BALANCING VALVE

CIRCUIT SETTER

GATE VALVE

QUICK OPENING VALVE

BALL VALVE

FLUID STRAINER

THERMOSTATIC VALVE

TRAP PRIMER

ELEC. CONTROL VALVE

MIXING VALVE

EMERGENCY MIXER

PRESSURE REDUCING VALVE

WATER METER

IRRIGATION METER

GAS REGULATOR

GAS SHUTOFF COCK

PLUG VALVE

EMERGENCY GAS SHUTOFF

2" CHECK

CWV

2" FD-3

2" FD-1

HUB DRAIN (FUNNEL TYPE)

ABBREVIATIONS

KEYNOTE SYMBOL

CONTINUATION SYMBOL

SHEET NUMBER WHERE DETAIL IS PLACED

DETAIL NUMBER ON SHEET

REVISION

GENERAL PLAN SYMBOLS

ROOM NAME / NUMBER

POINT WHERE NEW CONNECTS TO EXISTING

AREA NOT IN CONTRACT

SHEET NUMBER WHERE SECTION IS PLACED

SECTION NUMBER ON SHEET

CONSTRUCTION NOTE SYMBOL##

POINT WHERE DEMOLITION ENDS

DEMOLITION NOTE SYMBOL##

FLOOR SINK

ROOF DRAIN

DECK DRAIN

ROOM

PIPE RISE / PIPE DROP

PIPE CAP

CONTINUATION BREAK

CONNECT TO EXISTING

DIRECTION OF FLOW

FLEXIBLE CONNECTION

TEE TURNED DOWN / TEE

TURNED UP

2" BFV BUTTERFLY VALVE

2" GLOBE GLOBE VALVE

2" SOL SOLENOID VALVE

EXPANSION JOINT

UNION

2" WH WATER HAMMER

PIPE TYPES

CONSTRUCTION PHASING

EXISTING TO BE DEMOLISHED

NEW

(TYPICAL ALL SYMBOLS AND EQUIPMENT)

EXISTING

AREA BEING DEMOLISHED

DOMESTIC COLD-WATER

NON-POTABLE WATER

SOFT COLD-WATER

FILTERED COLD-WATER

REVERSE OSMOSIS WATER

DOMESTIC HOT-WATER

DOMESTIC HOT-WATER 140°

HOT-WATER RECIRCULATION

HOT-WATER RECIRCULATION 140°

SANITARY DRAIN

SANITARY VENT

SANITARY WET VENT

COMBINATION DWV

CONDENSATE DRAIN

INDIRECT DRAIN

GREASE WASTE

GREASE VENT

OIL WASTE

OIL VENT

PUMP DISCHARGE

SOLAR WATER RETURN

SOLAR WATER SUPPLY

STORM DRAIN

STORM OVERFLOW

COMPRESSED AIR

NATRUAL GAS

LIQUID PROPANE

XX.XX

PLUMBING GENERAL NOTES

1. IT IS INTENDED THAT A COMPLETE PLUMBING SYSTEM BE PROVIDED WITH ALL NECESSARY

EQUIPMENT, APPURTENANCES AND CONTROLS. THE CONTRACTOR MUST CAREFULLY REVIEW ALL

THE CONTRACT DOCUMENTS AND COORDINATE BETWEEN ALL TRADES PRIOR TO SUBMITTING SHOP DRAWINGS. THE CONTRACTOR MUST VERIFY ALL SIZES, MATERIALS, TEMPERATURE AND PRESSURE

RATINGS BEFORE ORDERING OR INSTALLING ANY MATERIALS OR EQUIPMENT.

2. THE CONTRACTOR MUST FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OR PURCHASE OF EQUIPMENT, MATERIALS AND ASSEMBLIES. THERE MAY EXIST FIELD CONDITIONS WHICH DIFFER

FROM THOSE SHOWN ON THESE DRAWINGS. ANY SUCH DEVIATIONS MUST BE BROUGHT TO THE

ATTENTION OF THE OWNER FOR RESOLUTION BEFORE PROCEEDING WITH ANY CONSTRUCTION,

FABRICATION, OR MATERIAL/EQUIPMENT PURCHASE WHICH WOULD BE UNUSABLE UNDER THOSE

CIRCUMSTANCES.

3. UNLESS NOTED OTHERWISE, CONSTRUCTION MATERIAL AND EQUIPMENT REMOVED SHALL BECOME

THE PROPERTY OF THE CONTRACTOR AND SHALL BE LEGALLY DISPOSED OF OFF THE SITE.

4. COORDINATE WORK WITH STRUCTURAL, DUCTWORK, SPRINKLER, ELECTRICAL AND ARCHITECTURAL

FEATURES AND PROVIDE OFFSETS AND FITTINGS AS REQUIRED.

5. COORDINATE WORK WITH ALL OTHER TRADES. CEILING HEIGHTS ON ARCHITECTURAL PLANS ARE

FINAL.

6. INSTALL ALL WORK IN ACCORDANCE WITH ALL APPLICABLE CODES AND REGULATIONS.

7. CONTRACTOR SHALL VERIFY LOCATION OF EXISTING UNDERGROUND UTILITIES AND PIPING BEFORE

COMMENCING WORK.

8. CONTRACTOR IS REQUIRED TO NOTIFY FACILITY OWNERS NOT LESS THAN 3 AND NOT MORE THAN 10

WORKING DAYS PRIOR TO EXCAVATION OR DEMOLITION WORK WHEN USING POWERED EQUIPMENT.

9. COORDINATE LOCATION OF ALL PIPING AND DEVICES BEFORE INSTALLATION WITH THE WORK OF

OTHER TRADES. WHERE A CONFLICT IN AVAILABLE CLEARANCES OCCURS, OBTAIN CLARIFICATION FROM OTHER TRADES OR ARCHITECT, AND PROVIDE WHATEVER ADDITIONAL PIPING, FITTINGS, ETC., ARE REQUIRED TO INSTALL PLUMBING SYSTEM.

10. VERIFY MOUNTING HEIGHTS OF EQUIPMENT FIXTURES W/ARCHITECT DRAWING BEFORE ROUGH-IN.

11. BUILDING STORM WATER, DOMESTIC WATER, SANITARY, & GAS PIPING SHALL BE EXTENDED TO LIMIT

DELINEATION OF CONTRACT LINE AS INDICATED ON DRAWINGS.

12. THE PLUMBING CONTRACTOR SHALL MAKE A COMPLETE WASTE, VENT, HOT & COLD WATER

CONNECTION TO ALL OWNER FURNISHED EQUIPMENT.

13. INSTALL ALL PLUMBING EQUIPMENT AND MATERIALS IN STRICT ACCORDANCE WITH RESPECTIVE

MANUFACTURER'S WRITTEN INSTRUCTIONS.

14. DIMENSIONS AND PIPE SIZES ARE IN INCHES UNLESS NOTED OTHERWISE.

15. RUN PIPING CONCEALED EXCEPT IN MECHANICAL ROOMS OR WHERE NOTED OTHERWISE.

16. RUN CONCEALED PIPING ON ROOM SIDE OF BUILDING INSULATION UNLESS NOTED OTHERWISE.

17. ALL EXPOSED PIPING SHALL BE CLEANED AND HAVE THE SURFACE PREPARED TO RECEIVE PAINTED

FINISH. PRIME AND PAINT THE EXPOSED PIPING IN COLOR AS SELECTED BY THE ARCHITECT.

18. RUN 2" MINIMUM SIZE WASTE PIPING BELOW GROUND INSIDE BUILDING REGARDLESS OF SIZE NOTED

ON FIXTURE SCHEDULE.

19. CONNECT WATER, WASTE, AND VENT PIPING TO FIXTURES IN ACCORDANCE WITH SIZES INDICATED

ON FIXTURE SCHEDULE.

20. SEAL ALL FLOOR AND WALL PENETRATIONS IN FIRE RATED CEILINGS AND PARTITIONS TO MAINTAIN

FIRE RATING. COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS.

21. COORDINATE ACCESS PANELS AND DOORS WITH ARCHITECT FEATURES.

22. CONTRACTOR SHALL PROVIDE PIPE SLEEVES IN ALL FOUNDATION WALLS FOR PIPING

PENETRATIONS.

23. ALL DOMESTIC WATER PIPING SHALL BE INSTALLED AS HIGH AS POSSIBLE, UNLESS OTHERWISE

INDICATED.

24. MAKE ALL FINAL CONNECTIONS TO THE EQUIPMENT AS SHOWN ON THE DRAWINGS. PROVIDE SHUT-

OFF VALVES IN ALL INDIVIDUAL WATER CONNECTIONS. IF APPLICABLE, PROVIDE SHUT-OFF VALVES IN

ALL INDIVIDUAL GAS CONNECTIONS.

25. INSTALL VACUUM BREAKER ON ALL DRAIN VALVES, WALL HYDRANTS, AND ALL HOSE CONNECTIONS.

26. FURNISH AND INSTALL ACCESS PANELS (FIRE-RATED) WHERE REQUIRED, WHERE SHOWN, OR

REQUIRED FOR ACCESS TO ALL CONCEALED VALVES, TRAPS OR OTHER EQUIPMENT FURNISHED

UNDER THIS CONTRACT WHERE NO OTHER MEANS IS PROVIDED.

27. INSTALL UNIONS ON PIPING TO PERMIT EASY DISCONNECTING.

28. THE CONTRACTOR SHALL RIGIDLY SUPPORT ALL EQUIPMENT.

29. ALL SANITARY AND STORM SEWER PIPING SHALL BE RUN AT 1/8" PER FOOT SLOPE UNLESS

OTHERWISE NOTED. ALL GREASE WASTE PIPING AND ALL SANITARY SEWER PIPING 2" AND SMALLER

SHALL BE RUN AT 1/4" PER FOOT SLOPE.

30. PROVIDE AND INSTALL ANGLE SHUTOFF VALVES AT EACH FIXTURE REQUIRING WATER. VALVES FOR

WALL MOUNTED FIXTURES SHALL BE CHROME PLATED, THREADED, HEAVY DUTY TYPE AND HAVE

LOOSE KEY STOPS. VALVES FOR COUNTERTOP FIXTURES SHALL BE 1/4 TURN BALL VALVES. PROVIDE SHUT-OFF VALVE IN ALL HOT WATER SUPPLY BRANCHES AND COMBINATION SHUT-OFF AND BALANCE VALVE IN ALL HOT WATER RETURN BRANCHES. LOCATE IN ACCESSIBLE CEILING SPACE OR IF INSIDE

EQUIPMENT ENCLOSURES, PROVIDE ACCESS DOOR.

31. DO NOT PLACE PIPING ABOVE ELECTRICAL PANELS, COMMUNICATIONS OR DATA EQUIPMENT.

32. COORDINATE THE EXACT LOCATION OF ALL ROOF OPENINGS AND SLAB PENETRATIONS WITH THE

STRUCTURAL DRAWINGS PRIOR TO INSTALLATION OF PLUMBING WORK.

33. UPON COMPLETED INSTALLATION, DRINKING WATER MUST BE TESTED FOR PH, LEAD, COPPER AND

TOTAL COLIFORMS. TESTING MUST BE CONDUCTED PRIOR TO THE CONTRACTOR ACCEPTANCE

INSPECTION.

34. EQUIPMENT SIZES SHOWN ARE BASED UPON TYPICAL MANUFACTURED EQUIPMENT AVAILABLE.

SHOP DRAWINGS MUST BE PROVIDED FOR REVIEW AND APPROVAL, SHOWING SPACE FOR ACCESS, EGRESS, MAINTENANCE AND REQUIRED CODE CLEARANCES PRIOR TO ANY PROCUREMENT, FABRICATION OR INSTALLATION.

Project No.:

Sheet No.:

M

AR

K D

AT

E

C O

M M

EN

TS

Date:

A

3000 WESTINGHOUSE DRIVE

SUITE 400

CRANBERRY TWP, PA 16066

(877) 323-6603

© Larson Design Group 2026

2 3 4 5 6 7 8 9 10

B

C

D

E

F

G

SEAL

Larson Design Group

/1 9/

:2 2:

A

M P

:\5

5\

5-

\P ar k B at hr oo m

A D

A P ro je ct \D

W G

\R ev it\

-0

5_

M o n tg om er y P a rk

_M E

P F

.r vt

5835-005

P-001

M O

N

TG

O M

ER

Y

PA

R

K B

A

TH

R O

O M

A D

A

IN

TE

R

IO

R

IM

PR

O

VE

M

EN

TS

1S T

ST

, M

O N

TG

O

M

ER

Y, P

A

10-19-2026

PL

U

M B

IN

G

G

EN

ER

A L

N O

TE

S, S

YM

B O

LS

A B

B R

EV

IA

TI

O

N S

IS

SU

ED

F

O R

B

ID

D

IN

G

M O

N

TG

O M

ER

Y

B O

R O

U G

H

S O

U

TH

M

AI

N S

TR

EE

T M

O N

TG

O

M

ER

Y, P

A

ABB DESCRIPTION

__________ A __________

& AND

< ANGLE

@ AT

AB CL ABOVE CEILING

AD ACCESS DOOR/AREA DRAIN

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

APPROX APPROXIMATE(LY)

ARCH ARCHITECT OR ARCHITECTURAL

AV ACID VENT, AUTOMATIC AIR VENT,

AUDIO VISUAL

AW ACID WASTE

__________ B __________

B/ BOTTOM OF

BET BETWEEN

BFG BELOW FINISHED GRADE

BFP BACKFLOW PREVENTER

BLW BELOW

BOS BOTTOM OF STRUCTURE

BOT BOTTOM

BTU BRITISH THERMAL UNIT

__________ C __________

CA COMPRESSED AIR

CD CONDENSATED DRAIN/CEILING

DIFFUSER

CF/CI CONTRACTOR FURNISHED,

CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED, OWNER

INSTALLED

CFH CUBIC FEET PER HOUR

CFM CUBIC FEET PER MINUTE

CI CAST IRON

CO CLEAN OUT, CLEAR OPENING

CONC CONCRETE

CW COLD WATER - DOMESTIC

__________ D __________

DDC DIRECT DIGITAL CONTROL, DOUBLE

DETECTOR CHECK VALVE

DF DRINKING FOUNTAIN

DIP DUCTILE IRON PIPE

DN DOWN

DST DEEP SEAL TRAP

__________ E __________

EC ELECTRICAL CONTRACTOR

EES EMERGENCY EYEWASH AND

SHOWER

ENGR ENGINEER

ETR EXISTING TO REMAIN

EWC ELECTRIC WATER COOLER

EXIST EXISTING

__________ F __________

FCO FLOOR CLEANOUT

FD FLOOR DRAIN, FIRE DAMPER

FD/T FLOOR DRAIN WITH TRAP PRIMER

FFE FINISHED FLOOR ELEVATION

FLR FLOOR

ABB DESCRIPTION

FS FLOOR SINK

__________ G __________

GC GENERAL CONTRACTOR

GH GROUND HYDRANT

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GW GREASE WASTE

GWH GAS WATER HEATER

__________ H __________

HB HOSE BIBB

HP HORSEPOWER

HW HOT WATER

HWR HOT WATER RETURN

__________ I __________

INV INVERT

__________ K __________

KVAR KILOVOLT-AMPERE REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

__________ L __________

LAV LAVATORY

LD LINEAR DRAIN

__________ M __________

MB MOP BASIN

MC MECHANICAL CONTRACTOR

__________ N __________

NC NORMALLY CLOSED

NFWH NON-FREEZE WALL HYDRANT

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NTS NOT TO SCALE

__________ O __________

OD OUTSIDE DIAMETER / OVERFLOW

DRAIN

OS&Y OUTSIDE STEM & YOKE

__________ P __________

P PRESSURE GAUGE

PC PLUMBING CONTRACTOR

PD PRESSURE DROP

PRV PRESSURE REDUCING VALVE,

POWER ROOF VENTILATOR

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PVC POLYVINYL CHLORIDE (CONDUIT)

PΔ PRESSURE DIFFERENCE

__________ R __________

RCP REFLECTED CEILING PLAN /

RECIRCULATION PUMP

RD ROOF DRAIN

RPM REVOLUTIONS PER MINUTE

RWC RAIN WATER CONDUCTOR

__________ S __________

S SOUTH, SOIL LINE, STACK, SINK

SD SMOKE DAMPER / SMOKE DETECTOR

/ SHOWER DRAIN

SH SHOWER

SK SERVICE SINK

SS SANITARY SEWER, STAINLESS STEEL

STD STANDARD

__________ T __________

T TREAD / TEMPERATURE /

THERMOMETER

TD TEMPERATURE DROP / TRENCH

DRAIN

TMW THERMAL MIXING VALVE

TYP TYPICAL

TΔ TEMPERATURE DIFFERENCE

__________ U __________

UNO UNLESS NOTED OTHERWISE

UR URINAL

__________ V __________

V VENT, VOLT

VIF VERIFY IN FIELD

VTR VENT THRU ROOF

__________ W __________

W WEST / WASTE

W/ WITH

W/O WITHOUT

WC WATER CLOSET / WATER COLUMN

WF WIDE FLANGE / WATER FOUNTAIN

WH WATER HEATER / WALL HYDRANT

WHA WATER HAMMER ARRESTOR

0-

-2

IS

S U

E D

F O

R B

ID

D

GENERAL REQUIREMENTS

A. GENERAL

1. CONFORM TO ALL GENERAL AND SPECIAL CONDITIONS OF CONTRACT AS SPECIFIED BY SITE ENGINEER’S AND/OR

OWNER.

2. VISIT SITE, CHECK FACILITIES AND CONDITIONS AND MAKE ALL NECESSARY OBSERVATIONS AND MEASUREMENTS. NOTE CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED AND TAKE ALL ITEMS INTO

CONSIDERATION IN BID.

3. SYSTEMS ARE TO BE COMPLETE AND WORKABLE IN ALL RESPECTS, PLACED IN OPERATION AND PROPERLY

ADJUSTED.

4. CONTRACTOR SHALL PROVIDE HIS OWN CLEAN-UP, REMOVAL AND LEGAL DISPOSAL OF ALL RUBBISH DAILY.

5. CONTRACTOR SHALL PROTECT HIS WORK, HIS EXISTING AND ADJACENT PROPERTY AGAINST WEATHER.

6. CONTRACTOR SHALL PROTECT HIS WORK, MATERIALS, APPARATUS AND FIXTURES FROM DAMAGE. ANY WORK DAMAGED BY FAILURE TO PROVIDE PROTECTION REQUIRED, SHALL BE REMOVED AND REPLACED WITH NEW

MATERIAL AT THE CONTRACTOR'S EXPENSE.

7. ARRANGE FOR AND OBTAIN OWNER'S AND INSURANCE REPRESENTATIVE'S PERMISSION FOR ANY SERVICE

SHUTDOWNS.

8. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, SEQUENCES OF

CONSTRUCTION AND THE SAFETY OF WORKMEN.

9. NO PIPING, DUCTWORK, WIRING, ETC. SHALL BE INSTALLED OR ROUTED ABOVE ELECTRICAL…