0DC2416 RLP Ex B - Agency Requirements -- Design Guide.pdf

PDF 7 MB Posted

Attached to
U. S. GOVERNMENT Solicitation Number: 0DC2416 The U. S. General Services Administration seeks to lease the following space:
Solicitation number
0DC2416
Issued by

About this file

This design guide outlines construction requirements for renovating and relocating offices for the U.S. Commodity Futures Trading Commission. It specifies 38 space types including chairman, commissioner, director, and other offices as well as conference rooms, training rooms, and shared workspaces. Requirements cover walls, ceilings, floors, doors, furniture, fixtures, equipment, finishes, electrical and mechanical systems. Audiovisual specifications and IT infrastructure guidelines are included in appendices. Space sketches illustrate example layouts. The document provides detailed product and construction standards to ensure consistency across the agency's headquarters and regional office renovations and relocations.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROPERTY OF THE UNITED STATES GOVERNMENT FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy documents when no longer needed

U.S. COMMODITY FUTURES

TRADING COMMISSION

(CFTC)

DESIGN GUIDE

April 2023

FOR REFERENCE ONLY

Contact DCHQRelo@cftc.gov for information mailto:DCHQRelo@cftc.gov

Page Purposely Left B lank

Page i

Table of Contents

CFTC GENERAL REQUIREMENTS

Type 1 CHAIRMAN OFFICE

Type 2 COMMISSIONER OFFICE

Type 3 DIRECTOR OFFICE

Type 4 SUPERVISORY OFFICE

Type 5 SUPERVISORY OFFICE

Type 6 NON-SUPERVISORY OFFICE

Type 7 WORKSTATION

Type 8 VISITOR’S OFFICE

Type 9 CONFERENCE ROOM

Type 9A CHAIRMAN’S CONFERENCE ROOM

Type 10 TRAINING ROOM

Type 11 TEAMING ROOM

Type 12 DEPOSITION ROOM

Type 13 NON-NETWORK PC & BLOOMBERG

Type 14 PANTRY

Type 14A CHAIRMAN’S PANTRY

Type 15 EMPLOYEE LOUNGE

Type 16 LEADERSHIP RECEPTION AREA

Type 17 RECEPTION AREA

Type 18 FILE ROOM

Type 19 STORAGE (HQ)

Type 20 STORAGE (Regions)

Type 21 MAIL, SUPPLY & PIV

Type 22 MOTHER’S ROOM

Type 22A GENDER NEUTRAL RESTROOM

Type 23 MAIL ROOM (HQ)

Type 24 PRINT / COPY

Type 25 ADP SERVER ROOM

Type 26 IDF SERVER CLOSET

Type 27 CONFERENCE CENTER ANTE ROOM

Type 27 CONFERENCE CENTER MAIN ROOM

Type 27 CONFERENCE CENTER AV CONTROL BOOTH

Type 27 CONFERENCE CENTER KITCHENETTE

Type 27 CONFERENCE CENTER STORAGE

Type 27 CONFERENCE CENTER MULTI-PURPOSE MEETING

Type 28 BADGING OFFICE

Type 29 PERSONNEL SECURITY OFFICE

Type 30 SECURITY GUARD ROOM

Type 31 AUDIO VISUAL STUDIO

Page ii

Type 32 LIBRARY PUBLIC READING ROOM

Type 33 DA IT CUSTOMER SERVICE CENTER HELP DESK

Type 34 CAA – See Separate “DESIGN GUIDE – SECURE SPACE”

Type 35 USER OPERATIONS TEST / DEPLOYMENT LAB

Type 36 NOT USED

Type 37 FORENSICS TRANSACTIONAL MEETING SPACE

Type 37A FORENSICS LAB

Type 38 NOT USED

APPENDIX 1 - IT REQUIREMENTS PROVIDED BY AGENCY

Specification 27 05 00 - INFORMATION TRANSPORT SYSTEMS INFRASTRUCTURE DESIGN

PART 1 GENERAL

PART 2 PRODUCTS

PART 3 EXECUTION

Specification 11 52 00 - AUDIO VISUAL EQUIPMENT

PART 1 TYPICAL ROOM SYSTEM REQUIREMENTS

1. Audio System

2. Video System

3. Control System

4. Rack Mounting System

APPENDIX 2 - FINISHES MATERIAL REFERENCE LIST

APPENDIX 3 - EQUIPMENT / APPLIANCE REFERENCE LIST

APPENDIX 4 – CFTC SIGNAGE STANDARD

ALL

CFTC GENERAL REQUIREMENTS

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 1 of 209 April 2023 - 2023-04-20 CFTC Design Guide

SUMMARY Relocation of CFTC existing regional and headquarters locations to new federal building assignment or lease locations.

LOCATIONS ▪ Headquarters – Washington, DC

▪ Eastern – New York, NY

▪ Central – Chicago, IL

▪ Southwestern – Kansas City, MO

ADJACENCIES

(GENERAL)

▪ Main Reception and the Gender-Neutral Restroom (GNR) should be adjacent to the public entrance / corridor

▪ Chairman, Commissioners, Directors, Leadership Reception should all be adjacent to each other

▪ The Visitor Office, Deposition Room and one (1) Conference Room and should be adjacent to the main Reception Area

▪ All other Conference Rooms, Teaming Rooms, Print Copy Areas and Pantries should be distributed throughout the overall space

▪ The Mail Room (HQ) or Mail – Supply – PIV (Regions), Supply and Storage Rooms should be adjacent to the service entrance and / or freight elevator.

DOORS /

FRAMES

▪ Full height, solid core, building standard wood doors, stained and varnished finish

▪ Manufacturer’s standard aluminum horizontal and vertical framing members for type system specified. Recommended manufacturer Infinium Wall Systems Refine Series or equal

▪ Manufacturer’s standard anchors, seals and miscellaneous trim necessary to complete all work and achieve the specified acoustical performance

HARDWARE All locking doors to be electric lock controlled by a remote card reader (coordinate system requirements with agency). Locking doors to be keyed to CFTC master key as fail safe in event of power outage

Lockset Types

▪ Mortise - Mortised or recessed into the edge of the door

▪ Cylindrical - Often called key-in-knob or key-in-lever locks

▪ Dead-Bolt – may also include Occupied / Vacant indicator

▪ Keypad – has numeric keypad requiring a number code to be entered

Lockset Functions

▪ Passage Function Both interior and exterior levers are always unlocked and free

▪ Office Function Interior push button, exterior key core. Interior push button locks door. Door unlocked with key on exterior or lever is turned on interior

▪ Privacy Function Interior push button locks door. Door unlocked when lever is turned on interior or with narrow tool from outside in case of emergency

▪ Storeroom Function Interior lever, exterior key core, always locked / fixed. Interior level always unlocked and free. Door unlocked only with key on exterior.

▪ Classroom Function Interior lever, exterior key core. Interior level always unlocked and free. Door locked or unlocked with key on exterior.

▪ Institutional Function Interior and exterior levers both fixed with key core. Interior and exterior both must use key to unlock.

FIRE Automatic sprinkler systems in accordance with all required and advisory provisions of NFPA 13 latest edition, by hydraulic calculations for light hazard occupancy with uniform water distribution

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 2 of 209

SUPPRESSION over the design area

ENVIRONMENTAL Separate zones (Variable Air Volume (VAV) with thermostat control), building standard distribution

ELECTRICAL ▪ Power outlets, whether wall or floor mounted, should be placed according to space layout, mounted at standard height unless otherwise noted on drawings

▪ Outlets to be commercial grade, 20Amp, 125Volt, 2 Pole, 3 Wire Grounding, NEMA 5-20R receptacle configuration

▪ Outlets near water source shall have Ground Fault Circuit Interrupter (GFCI) device

▪ Depending upon the space, dedicated circuits for equipment may be necessary, coordinate with CFTC Commission representative to confirm requirements

▪ Coordinate with CFTC Information Technology requirements in APPENDIX 1

LIGHTING ▪ Building standard LED, dimmable lighting as required to meet a minimum of 40 foot-candles at 30” Above Finished Floor (A.F.F.) over desk area or alternate, approved for same foot-candles

▪ In accordance with federal, state and local codes, lighting control to include ability to adjust or power lights in response to occupancy, power consumption and daylight available.

▪ Customize lighting layout and switching and review with Commission

▪ Match building standard lighting color temperature, unless otherwise noted on drawings

▪ Dimmable LED downlights over conference area with supplementary LED wall wash lighting

SECURITY ▪ Coordinate with CFTC Security for building entry and screening at each location

▪ Monitoring cameras will be located throughout the general tenant space

▪ If necessary, specific Space Types requiring additional cameras will be noted in that section

▪ See Table below for Access Control:

COMMUNICATION ▪ Refer to IT requirements chart; APPENDIX 1

▪ Communication Data Outlets and Wireless Access Points (WAPs) locations shall be coordinated with the Commission by the Architect / Engineer (A/E) in the final design

▪ CFTC internal Paging System will be furnished and installed by contractor and locations shall be coordinated with the Commission by the Architect / Engineer (A/E) in the final design

FINISHES

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 3 of 209

WALLS, FLOORS,

DOORS, FRAMES,

MILLWORK,

CEILINGS

Refer to Commission standard finishes in APPENDIX 2 for types and locations

FURNITURE FIXTURES & EQUIPMENT

EQUIPMENT (AGENCY PROVIDED) Refer to each Space Type for recommended equipment

FURNITURE (AGENCY PROVIDED) Refer to each Space Type for recommended furniture

SIGNAGE Refer to Commission standard signage in APPENDIX 4 for types and locations

SKETCHES ▪ Sketches for each space type are for illustration purposes only and are not drawn to scale.

They do not represent final configurations.

▪ Power and data connections and General Contractor provided items are noted in red text

▪ Furniture and equipment furnished by the Commission are noted in blue text

END OF GENERAL REQUIREMENTS

LOCATION: HQ

ROOM NAME: CHAIRMAN OFFICE SQUARE FT: 600

SPACE TYPE: Type 1 OCCUPANTS: 10 maximum ADJACENCIES: Executive Team

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 4 of 209

Type 1 CHAIRMAN OFFICE

CONSTRUCTION INFORMATION

MILLWORK N/A

DOORS / FRAMES ▪ Full height, single leaf, solid core, 36” wide, building standard wood door, stained and varnished finish

▪ Manufacturer’s standard aluminum horizontal and vertical framing members for type system specified. Recommended manufacturer Infinium Wall Systems Refine Series or equal

▪ Color(s) to be reviewed and approved by the Commission

HARDWARE Office Commercial grade hardware to match building standard style and finish. Final hardware to confirmed with Commission and meeting the following minimum requirements:

▪ heavyweight minimum 1 ½ pair butt hinges of quantities recommended by manufacturer for size and weight of door

▪ doorstop; commercial grade

▪ mortise lockset style, office function with interior push button and exterior key core, keyed to CFTC master, lever handles, electric lock controlled by a remote card reader (coordinate system requirements with Commission)

▪ two coat hooks, one installed at standard height, one installed at accessible height

Toilet Room Commercial grade hardware to match building standard style and finish. Final hardware to confirmed with Commission and meeting the following minimum requirements:

▪ heavyweight minimum 1 ½ pair butt hinges of quantities recommended by manufacturer for size and weight of door

▪ doorstop; commercial grade

▪ mortise lockset style, privacy function lockset with interior push button, lever handles

▪ two coat hooks, one installed at standard height, one installed at accessible height

WALLS ▪ Partitioning shall be one layer of ⅝” gypsum board to slab above on each side of 2 ½”, 25-gauge (or equivalent) metal studs at 24” On Center (O.C.)

▪ Adjust stud gauge, spacing and width to meet minimum deflection requirements in spaces with ceilings over 14’-0” in height. Brace partition to structure above with black iron or misc.

metal at 4’-0” O.C.

▪ Provide sound attenuating batt insulation between studs.

▪ Sound Transmission Class (STC) rating of 50 is required, Architect of Record to design or modify wall composition as necessary to meet

▪ Office front walls to be full-height, interior, unitized, double-glazed movable glass as shown and specified

▪ Manufacturer’s standard anchors, seals and miscellaneous trim necessary to complete all work and achieve the specified acoustical performance

▪ For side light windows and frames, recommended manufacturer Infinium Wall Systems

Refine Series or equal

▪ Insert material to be ¼” clear, tempered glass, verify the extent of glass with Commission

▪ Provide translucent film at glass in pattern and translucence selected by the Commission, 3M Matt Crystal1 (70-0709-0293-0) or approved equal

CEILING Office Tile

▪ Lay-in acoustic ceiling tiles, building standard size

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 5 of 209

▪ Light Reflectance Coefficient: 0.90

▪ Noise Reduction Coefficient: 0.75

▪ Ceiling Attenuation Coefficient: 3

Grid

▪ USG Fineline Tegular or equal

▪ Minimum ¾” thick with white enameled metal grid to match building standard

Toilet Room ▪ Gypsum board ceiling, with ⅝” thick gypsum board attached to metal drywall suspension system

▪ Paint ceiling in ceiling white color with low VOC content paint for gypsum board substrates: flat acrylic finish, minimum of two finish coats over primer

ACCESSORIES Toilet room accessories include:

▪ Grab Bars (near both toilet and inside shower)

▪ Toilet Tissue Dispenser

▪ Wall Mirror

▪ Towel Dispenser / Waste Receptacle Unit

▪ Seat Cover Dispenser

▪ Sanitary Napkin Dispenser

▪ Sanitary Napkin Waste Receptacle

Assume upgrade from building standard. All to be maintained by landlord. See APPENDIX 3 for recommended

PLUMBING Assume upgrade from building standard and selected by Commission

▪ One (1) Sink / Lavatory

▪ One (1) Faucet – Automatic

▪ One (1) Soap Dispenser – Automatic

▪ One (1) Toilet – Automatic Flush

▪ One (1) Shower stall with frosted, tempered glass door

All to be maintained by landlord. See APPENDIX 3 for recommended

ENVIRONMENTAL ▪ Separate zone (VAV with thermostat control), building standard distribution

▪ Switched exhaust fan for toilet room

ELECTRICAL ▪ Power outlets, whether wall or floor mounted, should be placed according to space layout,

▪ Outlets to be commercial grade, 20Amp, 125Volt, 2 Pole, 3 Wire Grounding, NEMA 5-20R plug configuration.

▪ Coordinate infrastructure and pathways with CFTC Information Technology requirements in

APPENDIX 1

▪ Outlets near water source shall have Ground Fault Circuit Interrupter (GFCI) device

LIGHTING ▪ Building standard LED dimmable lighting as required to meet a minimum of 40 foot-candles at 30” Above Finished Floor (A.F.F.) over desk area or alternate approved LED lighting to provide same foot-candles

▪ Dimmable LED downlights over seating and conference area with supplementary LED wall wash lighting

▪ Customize layout and review lighting layout and switching with Commission

▪ Match building standard color temperature

COMMUNICATION ▪ Refer to IT requirements in APPENDIX 1

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 6 of 209

WALLS Office ▪ Low VOC content paint for gypsum board substrates, eggshell finish, minimum of two finish coats over primer

▪ Color per Commission specifications

Toilet Room ▪ Porcelain or ceramic wall tile to height of four (4) feet with profile trim; tile to be selected by Commission

▪ Paint above tile with low VOC content paint for gypsum board substrates, eggshell finish, minimum of two finish coats over primer

▪ Color including accent paint or wallcovering, per Commission specifications

FLOOR / BASE Office ▪ Modular carpet tile

▪ Resilient base to be rubber, top set, ⅛” x 4”, with field formed external and internal corners – coved at hard floor finishes, straight at carpet floor finishes

Toilet Room ▪ Porcelain or ceramic floor tile, 12” x 12” or larger format, thin set, latex grout

▪ Matching porcelain or ceramic base; 4” minimum height

EQUIPMENT (AGENCY PROVIDED)

▪ PC or docking station, flat screen monitor(s), telephone handset and printer at desk

▪ Speaker telephone at conference table

▪ Television monitor, verify location and provide blocking as necessary

▪ Coordinate power and telecommunications connections per requirements in APPENDIX 1

FURNITURE (AGENCY PROVIDED)

▪ Desk, credenza and return, return to be height adjustable

▪ Dual monitor arm on the height adjustable table

▪ Laptop cable lock anchor

▪ Task chair (ergonomic with adjustable arms & seat height, mesh back and seat)

▪ Two (2) Guest chairs

▪ Four (4) upholstered chairs with occasional table

▪ Conference table with ten (10) chairs

▪ All files and storage shall be lockable

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 7 of 209

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

END OF SPACE Type 1

Four (4) upholstered chairs with occasional table

Conference table with ten (10) chairs

Two (2) guest chairs

Desk, height adjustable return with dual monitor arm and credenza Task chair

Bench and wardrobe cabinet Paper towel dispenser and waste receptacle

Automatic flush toilet, toilet tissue dispenser and toilet seat cover dispenser Grab Bars

Sink with automatic faucet and automatic soap dispenser

Shower stall with grab bars and frosted, tempered glass door

Television Monitor

Table Top Outlets

ROOM NAME: COMMISSIONER OFFICE SQUARE FT: 475

SPACE TYPE: Type 2 OCCUPANTS: 10 maximum

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 8 of 209

Type 2 COMMISSIONER OFFICE

MILLWORK: N/A

DOORS / FRAMES ▪ Full height, single leaf, solid core, 36” wide, building standard wood door, stained and

▪ Manufacturer’s standard aluminum horizontal and vertical framing members for type system

HARDWARE Office Commercial grade hardware to match building standard style and finish. Final hardware to confirmed with Commission and meeting the following minimum requirements:

▪ heavyweight minimum 1 ½ pair butt hinges of quantities recommended by manufacturer for size and weight of door

▪ doorstop; commercial grade

▪ mortise lockset style, office function lockset with interior push button and exterior key core, keyed to CFTC master, lever handles, electric lock controlled by a remote card reader (coordinate system requirements with

Commission)

▪ two coat hooks, one installed at standard height, one installed at accessible height

Toilet Room Commercial grade hardware to match building standard style and finish. Final hardware to confirmed with Commission and meeting the following minimum requirements:

▪ heavyweight minimum 1 ½ pair butt hinges of quantities recommended by manufacturer for size and weight of door

▪ doorstop; commercial grade

▪ mortise lockset style, privacy function lockset with interior push button, lever handles

▪ two coat hooks, one installed at standard height, one installed at accessible height

▪ Adjust stud gauge, spacing and width to meet minimum deflection requirements in spaces with ceilings over 14’-0” in height. Brace partition to structure above with black iron or misc.

metal at 4’-0” O.C.

▪ Provide sound attenuating batt insulation between studs.

▪ Sound Transmission Class (STC) rating of 50 is required, Architect of Record to design or modify wall composition as necessary to meet

▪ Manufacturer’s standard anchors, seals and miscellaneous trim necessary to complete all work and achieve the specified acoustical performance

▪ Office front walls to be full-height, interior, unitized, double-glazed movable glass as shown and specified

▪ For side light windows and frames, recommended manufacturer Infinium Wall Systems

Refine Series or equal

▪ Insert material to be ¼” clear, tempered glass, verify the extent of glass with Commission

CEILING Office Tile

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 9 of 209

▪ Light Reflectance Coefficient: 0.90

▪ Noise Reduction Coefficient: 0.75

▪ Ceiling Attenuation Coefficient: 3

Grid

▪ USG Fineline Tegular or equal

▪ Minimum ¾” thick with white enameled metal grid to match building standard

Toilet Room ▪ Gypsum board ceiling, with ⅝” thick gypsum board attached to metal drywall suspension system

▪ Paint ceiling in ceiling white color with low VOC content paint for gypsum board substrates: flat acrylic finish, minimum of two finish coats over primer

ACCESSORIES Assume upgrade from building standard. Toilet room accessories include:

▪ Grab Bars (near both toilet and inside shower)

▪ Toilet Tissue Dispenser

▪ Wall Mirror

▪ Towel Dispenser / Waste Receptacle Unit

▪ Seat Cover Dispenser

▪ Sanitary Napkin Dispenser and

▪ Sanitary Napkin Waste Receptacle

PLUMBING Assume upgrade from building standard and selected by Commission

▪ One (1) Sink / Lavatory

▪ One (1) Faucet – Automatic

▪ One (1) Soap Dispenser – Automatic

▪ One (1) Toilet – Automatic Flush

▪ One (1) Shower stall with frosted, tempered glass door

ENVIRONMENTAL ▪ Separate zone (VAV with thermostat control), standard distribution

▪ Switched exhaust fan for toilet room

ELECTRICAL ▪ Power outlets, whether wall or floor mounted, should be placed according to space layout,

▪ Outlets to be commercial grade, 20Amp, 125Volt, 2 Pole, 3 Wire Grounding, NEMA 5-20R plug configuration.

▪ Coordinate infrastructure and pathways with CFTC Information Technology requirements in

▪ Outlets near water source shall have Ground Fault Circuit Interrupter (GFCI) device

LIGHTING ▪ Dimmable building standard LED lighting as required to meet a minimum of 40 foot-candles at 30” Above Finished Floor (A.F.F.) over desk area or alternate approved LED lighting to provide same foot-candles

▪ Dimmable LED downlights over seating and conference area with supplementary LED wall wash lighting

▪ Communication outlet locations shall be coordinated with the Commission by the Architect /

Engineer in the final design

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 10 of 209

WALLS Office ▪ Low VOC content paint for gypsum board substrates, eggshell finish, minimum of two finish coats over primer

▪ Color per Commission specifications

Toilet Room ▪ Porcelain or ceramic wall tile to height of 4 feet with profile trim; tile to be selected by Commission

▪ Paint above tile with low VOC content paint for gypsum board substrates, eggshell finish, minimum of two finish coats over primer

▪ Color including accent paint or wallcovering, per Commission specifications

FLOOR / BASE Office ▪ Modular carpet tile

▪ Resilient base to be rubber, top set, 1/8” x 4”, with field formed external and internal corners – coved at hard floor finishes, straight at carpet floor finishes

▪ Stained and varnished wood base is optional if approved by Commission

Toilet Room ▪ Porcelain or ceramic floor tile, 12” x 12” or larger format, thin set, latex grout

▪ Matching porcelain or ceramic base; 4” minimum height

▪ Speaker telephone at conference table

▪ Dual monitor arm on the height adjustable table

▪ Laptop cable lock anchor

▪ Task chair (ergonomic with adjustable arms & seat height, mesh back and seat)

▪ Two (2) Guest chairs

▪ All files and storage shall be lockable

▪ Two (2) upholstered chairs and one (1) sofa

▪ Conference table with eight (8) chairs

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 11 of 209

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

END OF SPACE Type 2

One (1) upholstered sofa and two (2) upholstered chairs

Conference table with eight (8) chairs

Two (2) guest chairs

Desk, height adjustable return with dual monitor arm and credenza

Task chair

Bench and wardrobe cabinet Paper towel dispenser and waste receptacle

Automatic flush toilet, toilet tissue dispenser and toilet seat cover dispenser Grab Bars

Sink with automatic faucet and automatic soap dispenser

Shower stall with grab bars and frosted, tempered glass door

ROOM NAME: DIRECTOR OFFICE SQUARE FT: 275

SPACE TYPE: Type 3 OCCUPANTS: 8 maximum

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 12 of 209

Type 3 DIRECTOR OFFICE

DOORS / FRAMES ▪ Full height, single leaf, solid core, 36” wide, building standard wood door, stained and

▪ Manufacturer’s standard aluminum horizontal and vertical framing members for type system

HARDWARE Commercial grade hardware to match building standard style and finish. Final hardware to confirmed with Commission and meeting the following minimum requirements:

▪ heavyweight minimum 1 ½ pair butt hinges of quantities recommended by manufacturer for size and weight of door

▪ doorstop; commercial grade

▪ mortise lockset style, office function lockset with interior push button and exterior key core, keyed to CFTC master, lever handles, electric lock controlled by a remote card reader

(coordinate system requirements with Commission)

▪ two coat hooks, one installed at standard height, one installed at accessible height

▪ Adjust stud gauge, spacing and width to meet minimum deflection requirements in spaces with ceilings over 14’-0” in height. Brace partition to structure above with black iron or misc.

metal at 4’-0” O.C.

▪ Provide sound attenuating batt insulation between studs.

▪ Sound Transmission Class (STC) rating of 50 is required, Architect of Record to design or modify wall composition as necessary to meet

▪ Manufacturer’s standard anchors, seals and miscellaneous trim necessary to complete all work and achieve the specified acoustical performance

▪ Office front walls to be full-height, interior, unitized, double-glazed movable glass as shown and specified

▪ For side light windows and frames, recommended manufacturer Infinium Wall Systems

Refine Series or equal

▪ Insert material to be ¼” clear, tempered glass, verify the extent of glass with Commission

CEILING Tile

▪ Light Reflectance Coefficient: 0.90

▪ Noise Reduction Coefficient: 0.75

▪ Ceiling Attenuation Coefficient: 3

Grid

▪ USG Fineline Tegular or equal

▪ Minimum ¾” thick with white enameled metal grid to match building standard

ACCESSORIES N/A

ENVIRONMENTAL Separate zone (VAV with thermostat control), building standard distribution

ELECTRICAL ▪ Power outlets, whether wall or floor mounted, should be placed according to space layout, REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 13 of 209

▪ Outlets to be commercial grade, 20Amp, 125Volt, 2 Pole, 3 Wire Grounding, NEMA 5-20R plug configuration

▪ Coordinate infrastructure and pathways with CFTC Information Technology requirements in

LIGHTING ▪ Building standard 24”x24” LED Dimmable lighting as required to meet a minimum of 40 foot-candles at 30” Above Finished Floor (A.F.F.) over desk area or alternate approved LED lighting to provide same foot-candles

▪ Dimmable LED downlights over conference area with supplementary LED wall wash lighting

WALLS ▪ Low VOC content paint for gypsum board substrates, eggshell finish, minimum of two finish coats over primer

▪ Color per Commission specifications

FLOOR / BASE ▪ Modular carpet tile

▪ Resilient base to be rubber, top set, 1/8” x 4”, with field formed external and internal corners

– coved at hard floor finishes, straight at carpet floor finishes

▪ Stained and varnished wood base is optional if approved by Commission

▪ Speaker telephone at conference table

▪ Dual monitor arm on the height adjustable table

▪ Laptop cable lock anchor

▪ Task chair (ergonomic with adjustable arms & seat height, mesh back and seat)

▪ Two (2) Guest chairs

▪ All files and storage shall be lockable

▪ Conference table with four (4) chairs

▪ Two (2) upholstered chairs with occasional table

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 14 of 209

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

END OF SPACE Type 3

Two (2) upholstered chairs with occasional table

Conference table with four (4) chairs

Two (2) guest chairs

Desk, height adjustable return with dual monitor arm and credenza Task chair

Television Monitor

LOCATION: ALL

ROOM NAME: SUPERVISORY OFFICE CT 16 - 17 SQUARE FT: 150

SPACE TYPE: Type 4 OCCUPANTS: 5 maximum

ADJACENCIES:

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 15 of 209

Type 4 SUPERVISORY OFFICE

DOORS / FRAMES ▪ Full height, single leaf, solid core, 36” wide, building standard wood door, stained and

▪ Manufacturer’s standard aluminum horizontal and vertical framing members for type system

▪ heavyweight minimum 1 ½ pair butt hinges of quantities recommended by manufacturer for size and weight of door

▪ doorstop; commercial grade

▪ mortise lockset style, office function lockset with interior push button and exterior key core, keyed to CFTC master, lever handles, electric lock controlled by a remote card reader

▪ Adjust stud gauge, spacing and width to meet minimum deflection requirements in spaces with ceilings over 14’-0” in height. Brace partition to structure above with black iron or misc.

metal at 4’-0” O.C.

▪ Provide sound attenuating batt insulation between studs.

▪ Sound Transmission Class (STC) rating of 50 is required, Architect of Record to design or modify wall composition as necessary to meet

▪ Manufacturer’s standard anchors, seals and miscellaneous trim necessary to complete all work and achieve the specified acoustical performance

▪ Office front walls to be full-height, interior, unitized, double-glazed movable glass as shown and specified

▪ For side light windows and frames, recommended manufacturer Infinium Wall Systems

Refine Series or equal

▪ Insert material to be ¼” clear, tempered glass, verify the extent of glass with Commission

▪ Light Reflectance Coefficient: 0.90

▪ Noise Reduction Coefficient: 0.75

▪ Ceiling Attenuation Coefficient: 3

Grid

ENVIRONMENTAL Code required, building standard distribution

ELECTRICAL ▪ Power outlets, whether wall or floor mounted, should be placed according to space layout, REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 16 of 209 plug configuration

LIGHTING Building standard (LED preferred) lighting as required to meet a minimum of 40 foot-candles at

30” Above Finished Floor (A.F.F.)

Match building standard color temperature

- coved at hard floor finishes, straight at carpet floor finishes

▪ Speaker telephone at conference table

▪ Desk and return, wood laminate finish, return to be height adjustable

▪ Dual monitor arm on the height adjustable table

▪ Laptop cable lock anchor

▪ Metal lockable lateral file & shelf combo located at the front of the desk

▪ Metal lockable, movable box / file

▪ All files to be lockable

▪ Task chair (ergonomic with adjustable arms & seat height, mesh back and seat)

▪ Desk top power / USB charging module

▪ Four (4) guest chairs

▪ One (1) 36” diameter meeting table (wood laminate finish)

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 17 of 209

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

END OF SPACE Type 4

Two (2) guest chairs with occasional table

Two (2) guest chairs

Desk, height adjustable return with dual monitor arm

Task chair

Bookcase File

Cabinet combination unit

Television

Monitor

ROOM NAME: SUPERVISORY OFFICE CT 15 and below SQUARE FT: 120 SPACE TYPE: Type 5 OCCUPANTS: 1 each

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 18 of 209

Type 5 SUPERVISORY OFFICE

DOORS / FRAMES ▪ Full height, single leaf, solid core, 36” wide, building standard wood door, stained and

▪ Manufacturer’s standard aluminum horizontal and vertical framing members for type system

▪ heavyweight minimum 1 ½ pair butt hinges of quantities recommended by manufacturer for size and weight of door

▪ doorstop; commercial grade

▪ mortise lockset style, office function lockset with interior push button and exterior key core, keyed to CFTC master, lever handles, electric lock controlled by a remote card reader

▪ Adjust stud gauge, spacing and width to meet minimum deflection requirements in spaces with ceilings over 14’-0” in height. Brace partition to structure above with black iron or misc.

metal at 4’-0” O.C.

▪ Provide sound attenuating batt insulation between studs.

▪ Sound Transmission Class (STC) rating of 50 is required, Architect of Record to design or modify wall composition as necessary to meet

▪ Manufacturer’s standard anchors, seals and miscellaneous trim necessary to complete all work and achieve the specified acoustical performance

▪ Office front walls to be full-height, interior, unitized, double-glazed movable glass as shown and specified

▪ For side light windows and frames, recommended manufacturer Infinium Wall Systems

Refine Series or equal

▪ Insert material to be ¼” clear, tempered glass, verify the extent of glass with Commission

▪ Light Reflectance Coefficient: 0.90

▪ Noise Reduction Coefficient: 0.75

▪ Ceiling Attenuation Coefficient: 3

Grid

PLUMBING N/A

ELECTRICAL ▪ Power outlets, whether wall or floor mounted, should be placed according to space layout, REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 19 of 209 plug configuration

LIGHTING ▪ Building standard (LED preferred) lighting as required to meet a minimum of 40 foot-candles at 30” Above Finished Floor (A.F.F.)

▪ Dual monitor arm on the height adjustable table and

▪ Laptop cable lock anchor

▪ Metal lockable lateral file & shelf combo located at the front of the desk

▪ Metal lockable, movable box / file

▪ All files to be lockable

▪ Task chair (ergonomic with adjustable arms & seat height, mesh back and seat)

▪ Desk top power / USB charging module

▪ Two (2) guest chairs

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 20 of 209

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

END OF SPACE Type 5

Two (2) guest chairs

Desk, height adjustable return with dual monitor arm Task chair

Bookcase File

Cabinet combination unit

ROOM NAME: NON-SUPERVISORY OFFICE CT 9 - 18 SQUARE FT: 100

SPACE TYPE: Type 6 OCCUPANTS: 1 each

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 21 of 209

Type 6 NON-SUPERVISORY OFFICE

DOORS / FRAMES ▪ Full height, single leaf, solid core, 36” wide, building standard wood door, stained and

▪ Manufacturer’s standard aluminum horizontal and vertical framing members for type system

▪ heavyweight minimum 1 ½ pair butt hinges of quantities recommended by manufacturer for size and weight of door

▪ doorstop; commercial grade

▪ mortise lockset style, office function lockset with interior push button and exterior key core, keyed to CFTC master, lever handles, electric lock controlled by a remote card reader

▪ Adjust stud gauge, spacing and width to meet minimum deflection requirements in spaces with ceilings over 14’-0” in height. Brace partition to structure above with black iron or misc.

metal at 4’-0” O.C.

▪ Provide sound attenuating batt insulation between studs.

▪ Sound Transmission Class (STC) rating of 50 is required, Architect of Record to design or modify wall composition as necessary to meet

▪ Manufacturer’s standard anchors, seals and miscellaneous trim necessary to complete all work and achieve the specified acoustical performance

▪ Office front walls to be full-height, interior, unitized, double-glazed movable glass as shown and specified

▪ For side light windows and frames, recommended manufacturer Infinium Wall Systems

Refine Series or equal

▪ Insert material to be ¼” clear, tempered glass, verify the extent of glass with Commission

▪ Light Reflectance Coefficient: 0.90

▪ Noise Reduction Coefficient: 0.75

▪ Ceiling Attenuation Coefficient: 3

Grid

ELECTRICAL ▪ Power outlets, whether wall or floor mounted, should be placed according to space layout, REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 22 of 209 plug configuration

LIGHTING ▪ Building standard (LED preferred) lighting as required to meet a minimum of 40 foot-candles

▪ PC or docking station, flat screen monitor(s) and telephone handset

▪ Dual monitor arm on the height adjustable table and

▪ Laptop cable lock anchor

▪ Metal lockable lateral file & shelf combo located at the front of the desk

▪ Metal lockable, movable box / file

▪ All files to be lockable

▪ Task chair (ergonomic with adjustable arms & seat height, mesh back and seat)

▪ One (1) guest chair

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 23 of 209

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

END OF SPACE Type 6

One (1) guest chair

Desk, height adjustable return with dual monitor arm Task chair

Bookcase File

LOCATION ALL

ROOM NAME: WORKSTATION SQUARE FT: 48

SPACE TYPE: Type 7 OCCUPANTS: 1 each

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 24 of 209

Type 7 WORKSTATION

DOORS / FRAMES N/A

HARDWARE N/A

WALLS N/A

▪ Light Reflectance Coefficient: 0.90

▪ Noise Reduction Coefficient: 0.75

▪ Ceiling Attenuation Coefficient: 3

Grid

ELECTRICAL ▪ Systems Furniture to be powered by hard wire connection to panels in a circuit configuration requirement to be provide by Systems Furniture manufacturer.

▪ Outlets mounted in Systems Furniture to be furnished and installed by Systems Furniture installer.

▪ Power outlets, whether wall or floor mounted, should be placed according to space layout, mounted at standard height unless otherwise noted on drawings

▪ Outlets to be commercial grade, 20Amp, 125Volt, 2 Pole, 3 Wire Grounding, NEMA 5-20R plug configuration

LIGHTING ▪ Building standard (LED preferred) lighting as required to meet a minimum of 40 foot-candles

WALLS N/A

LOCATION ALL

ROOM NAME: WORKSTATION SQUARE FT: 48

SPACE TYPE: Type 7 OCCUPANTS: 1 each

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 25 of 209

▪ Solid color systems furniture with low panels & height adjustable desk

▪ Dual monitor arm on the height adjustable table

▪ Laptop cable lock anchor

▪ Desk top power / USB charging module

▪ Task chair (ergonomic with adjustable arms & seat height, mesh back and seat)

▪ Narrow Wardrobe (Approximately 9” wide), (Height range: 48” – 54”)

▪ Metal Storage and lockable files as the space allows

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

END OF SPACE Type 7

Desk, height adjustable return with dual monitor arm

Task chair

Locker, Bookcase

& File Cabinet

ROOM NAME: VISITOR’S OFFICE SQUARE FT: 100

SPACE TYPE: Type 8 OCCUPANTS: 1 each ADJACENCIES: Main Entrance

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 26 of 209

Type 8 VISITOR’S OFFICE

DOORS / FRAMES ▪ Full height, single leaf, solid core, 36” wide, building standard wood door, stained and

▪ Manufacturer’s standard aluminum horizontal and vertical framing members for type system

▪ heavyweight minimum 1 ½ pair butt hinges of quantities recommended by manufacturer for size and weight of door

▪ doorstop; commercial grade

▪ mortise lockset style, office function lockset with interior push button and exterior key core, keyed to CFTC master, lever handles, electric lock controlled by a remote card reader

▪ Adjust stud gauge, spacing and width to meet minimum deflection requirements in spaces with ceilings over 14’-0” in height. Brace partition to structure above with black iron or misc.

metal at 4’-0” O.C.

▪ Provide sound attenuating batt insulation between studs.

▪ Sound Transmission Class (STC) rating of 50 is required, Architect of Record to design or modify wall composition as necessary to meet

▪ Manufacturer’s standard anchors, seals and miscellaneous trim necessary to complete all work and achieve the specified acoustical performance

▪ Office front walls to be full-height, interior, unitized, double-glazed movable glass as shown and specified

▪ For side light windows and frames, recommended manufacturer Infinium Wall Systems

Refine Series or equal

▪ Insert material to be ¼” clear, tempered glass, verify the extent of glass with Commission

▪ Light Reflectance Coefficient: 0.90

▪ Noise Reduction Coefficient: 0.75

▪ Ceiling Attenuation Coefficient: 3

Grid

ELECTRICAL ▪ Power outlets, whether wall or floor mounted, should be placed according to space layout, REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 27 of 209 plug configuration

LIGHTING ▪ Building standard (LED preferred) lighting as required to meet a minimum of 40 foot-candles

▪ Dual monitor arm on the height adjustable table and

▪ Laptop cable lock anchor

▪ Metal lockable lateral file & shelf combo located at the front of the desk

▪ Metal lockable, movable box / file

▪ All files to be lockable

▪ Task chair (ergonomic with adjustable arms & seat height, mesh back and seat)

▪ One (1) guest chair

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 28 of 209

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

END OF SPACE Type 8

One (1) guest chair

Desk, height adjustable return with dual monitor arm Task chair

Bookcase File

ROOM NAME: CONFERENCE ROOM SQUARE FT: 500

SPACE TYPE: Type 9 OCCUPANTS: 14 - 20 ADJACENCIES: Reception, Working Zone

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 29 of 209

Type 9 CONFERENCE ROOM

DOORS / FRAMES ▪ Full height, single leaf, solid core, 36” wide, building standard wood door, stained and

▪ Manufacturer’s standard aluminum horizontal and vertical framing members for type system

▪ heavyweight minimum 1 ½ pair butt hinges of quantities recommended by manufacturer for size and weight of door

▪ doorstop; commercial grade

▪ mortise lockset style, office function lockset with interior push button and exterior key core, keyed to CFTC master, lever handles, electric lock controlled by a remote card reader

▪ provide automatic door bottom and perimeter gasketing as necessary to achieve STC rating

WALLS ▪ Partitioning shall be one layer of ⅝” gypsum board full height to slab above on each side of

2 ½”, 25-gauge (or equivalent) metal studs at 24” O.C.

▪ Adjust stud gauge, spacing and width to meet minimum deflection requirements in spaces with ceilings over 14’-0” in height.

▪ Provide sound attenuating batt insulation between studs

▪ STC rating of 50 is required, Architect of Record to design or modify wall composition as necessary to meet

▪ Light Reflectance Coefficient: 0.90

▪ Noise Reduction Coefficient: 0.75

▪ Ceiling Attenuation Coefficient: 3

Grid

ENVIRONMENTAL Separate zone and controls (separate VAV and thermostat) with code-required ventilation and building distribution designed for occupant load

ELECTRICAL ▪ Power outlets, whether wall or floor mounted, should be placed according to space layout,

▪ Outlets to be commercial grade, 20Amp, 125Volt, 2 Pole, 3 Wire Grounding, NEMA 5-20R plug configuration

▪ Coordinate floor outlet locations with furniture and connect to tabletop as required. Quantity located in table to be confirmed by Commission

▪ Coordinate infrastructure and pathways with CFTC audiovisual requirements, wiring and connections per Commission specifications in APPENDIX 1

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 30 of 209

LIGHTING ▪ Building standard (LED preferred) dimmable lighting or alternate downlights as required to meet a minimum of 40 foot-candles at 30” Above Finished Floor (A.F.F.)

▪ All lighting shall be dimmable to 1% with a simple control

COMMUNICATION Refer to IT requirements chart; APPENDIX 1

Engineer in the final design

▪ For floor receptacles one receptacle is required for every 215 square feet of floor space in meeting rooms that are at least 12 feet wide

▪ Coordinate floor outlet locations with furniture and connect to tabletop module if required.

Verify requirements at each location

▪ Area shall be equipped with sound masking system

▪ Color including accent paint, and one wall of wallcovering, per Commission specifications

▪ Conference telephone handset

▪ Three (3) wall mounted flat screen monitors (controlled from table), provide blocking as necessary

▪ Video conference equipment

▪ One (1) wood laminate conference table sized to fit the dimensions and configuration of the room (power and data outlets mounted on the table shall be non-obtrusive)

▪ White board

▪ Minimum sixteen (16) ergonomic chairs (with fixed arms & height adjustable seat, mesh back and upholstered seat)

▪ Credenza with 30" depth to store IT / AV equipment adequately (with exhaust fan or vent if required) and top surface for serving

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 31 of 209

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

END OF SPACE Type 9

Credenza

Television Monitors Conference

Room Chairs

Marker Board

Table Top Outlets

Television Monitor

Room Scheduler Conference

Table

ROOM NAME: CHAIRMAN’S CONFERENCE ROOM SQUARE FT: 500

SPACE TYPE: Type 9A OCCUPANTS: 14 - 20 ADJACENCIES: Leadership Reception Area, Chairman and Commissioner Offices

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 32 of 209

Type 9A CHAIRMAN’S CONFERENCE ROOM

DOORS / FRAMES ▪ Full height, single leaf, solid core, 36” wide, building standard wood door, stained and

▪ Manufacturer’s standard aluminum horizontal and vertical framing members for type system

▪ heavyweight minimum 1 ½ pair butt hinges of quantities recommended by manufacturer for size and weight of door

▪ doorstop; commercial grade

▪ mortise lockset style, office function lockset with interior push button and exterior key core, keyed to CFTC master, lever handles, electric lock controlled by a remote card reader

▪ Adjust stud gauge, spacing and width to meet minimum deflection requirements in spaces with ceilings over 14’-0” in height.

▪ Provide sound attenuating batt insulation between studs

▪ STC rating of 50 is required, Architect of Record to design or modify wall composition as necessary to meet

▪ Light Reflectance Coefficient: 0.90

▪ Noise Reduction Coefficient: 0.75

▪ Ceiling Attenuation Coefficient: 3

Grid

ENVIRONMENTAL Separate zone and controls (separate VAV and thermostat) with code-required ventilation and

ELECTRICAL ▪ Power outlets, whether wall or floor mounted, should be placed according to space layout,

▪ Outlets to be commercial grade, 20Amp, 125Volt, 2 Pole, 3 Wire Grounding, NEMA 5-20R plug configuration

▪ Coordinate floor outlet locations with furniture and connect to tabletop as required. Quantity located in table to be confirmed by Commission

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 33 of 209

LIGHTING ▪ Building standard (LED preferred) dimmable lighting or alternate downlights as required to

Engineer in the final design

▪ For floor receptacles one receptacle is required for every 215 square feet of floor space in meeting rooms that are at least 12 feet wide

▪ Coordinate floor outlet locations with furniture and connect to tabletop module if required.

Verify requirements at each location

▪ Area shall be equipped with sound masking system

▪ Public Broadcasts and Webcasting Events: the space must accommodate in room participation as well as broadcast capabilities for both in house webcasting services and public broadcasting

▪ Conference telephone handset

▪ Three (3) wall mounted flat screen monitors (controlled from Secretariat Technical Table), provide blocking as necessary

▪ Video conference equipment

▪ Secretariat Technical Table with controls for A/V systems

▪ One (1) wood laminate conference table sized to fit the dimensions and configuration of the room (power and data outlets mounted on the table shall be non-obtrusive)

▪ White board

▪ Minimum sixteen (16) ergonomic chairs (with fixed arms & height adjustable seat, mesh back and upholstered seat)

▪ Credenza with 30" depth to store IT / AV equipment adequately (with exhaust fan or vent if required) and top surface for serving

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 34 of 209

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

Sketches are for illustration purposes only and are not drawn to scale. They do not represent final configurations.

END OF SPACE Type 9A

Television Monitors

Conference Room Chairs

Marker Board

Table Top Outlets

Television Monitor

Room Scheduler

Conference Table

Audio Visual Equipment

Racks

Secretariat Technical

Table

LOCATION: HQ and Kansas City

ROOM NAME: TRAINING ROOM SQUARE FT: 500

SPACE TYPE: Type 10 OCCUPANTS: 30 maximum ADJACENCIES: Entrance, Reception

REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 35 of 209

Type 10 TRAINING ROOM

DOORS / FRAMES ▪ Full height, single leaf, solid core, 36” wide, building standard wood door, stained and

▪ Manufacturer’s standard aluminum horizontal and vertical framing members for type system

▪ heavyweight minimum 1 ½ pair butt hinges of quantities recommended by manufacturer for size and weight of door

▪ doorstop; commercial grade

▪ mortise lockset style, office function lockset with interior push button and exterior key core, keyed to CFTC master, lever handles, electric lock controlled by a remote card reader

▪ Adjust stud gauge, spacing and width to meet minimum deflection requirements in spaces with ceilings over 14’-0” in height.

▪ Provide sound attenuating batt insulation between studs

▪ STC rating of 50 is required, Architect of Record to design or modify wall composition as necessary to meet

▪ Manufacturer’s standard anchors, seals and miscellaneous trim necessary to complete all work and achieve the specified acoustical performance

If Applicable

▪ One wall may be full-height, interior, unitized, double-glazed movable glass as shown and specified

▪ For side light windows and frames, recommended manufacturer Infinium Wall Systems

Refine Series or equal

▪ Insert material to be ¼” clear, tempered glass, verify the extent of glass with Commission

▪ Light Reflectance Coefficient: 0.90

▪ Noise Reduction Coefficient: 0.75

▪ Ceiling Attenuation Coefficient: 3

Grid

ENVIRONMENTAL Separate zone and controls (separate VAV and thermostat) with code-required ventilation and

ELECTRICAL ▪ Power outlets, whether wall or floor mounted, should be placed according to space layout, REQUIREMENTS for: U.S. Commodity Futures Trading Commission (CFTC) Page 36 of 209 plug configuration

▪ Coordinate floor outlet locations with furniture and connect to tabletop as required. Quantity located in table to be confirmed by Commission

▪ Coordinate infrastructure and pathways with CFTC audiovisual requirements, wiring and

▪ Coordinate with Commission requirements for lectern

LIGHTING ▪ Building standard (LED preferred) dimmable lighting or alternate downlights as required to

Engineer in the final design

▪ Coordinate floor outlet locations with furniture and connect to tabletop module if required.

Verify requirements at each location

▪ Area shall be equipped with sound masking system

▪ Specialized Network availability to be provided (Separated from working zone network system)

▪ Conference telephone handset and video tele-conference equipment

▪ Two (2) wall mounted flat screen monitors (control from table), provide…