This document is a combined synopsis/solicitation for a Request for Quotation (RFQ) from the Department of the Navy Naval Sea Systems Command for chamber ceiling repairs. The requirement involves repairing or altering industrial buildings and is not eligible for a small business set-aside. The government intends to award a sole source contract to Venturedyne, LTD dba Thermontron Industries based on the Statement of Work, as their products are required to avoid additional configuration management, testing, and integration costs. Proposals are due by October 21, 2024, and the contract will be a firm-fixed-price order awarded using Simplified Acquisition Procedures. Award will be based on the lowest price technically acceptable offer. The government is seeking historical data and published pricing from offerors who must be registered in the System for Award Management.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SF1449 - Solicitation (Final).pdf | ||
| N0017825Q6609_ FAR 13.5 Combined Synopsis Solicitation.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
102.88
484.00
3X76.88
HIGH
DOOR
58.00 58.00 58.00
6X 6.00 PORT
8.00
8.00 3X59.88
78.13 78.13 78.13 43.00 85.88 79.88
5.50IN
DEEP PIT
CHAMBERS
CHAMBER
A
CHAMBER
B
CHAMBER
C
CONTROL
STATION
SIDE DOOR
A DOOR
B
DOOR
C
DOOR
BLOWERS
AB
PARTITION
DOOR
CONDITIONERS
76.88
56.00 116.00
91.00
A A
B B
9462 TRIPLE
CHAMBER
DO NOT SCALE DRAWING SHEET 1 OF 4
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:80 WEIGHT:
REVDWG. NO.
B
SIZE
TITLE:
NAME DATE
COMMENTS:
REFER TO "CHAMBER MODELS.DOCX"
FOR NOTES ON MODEL AND DRAWING.
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH BEND
TWO PLACE DECIMAL
THREE PLACE DECIMAL
APPLICATION
USED ONNEXT ASSY
PROPRIETARY AND CONFIDENTIAL
77.00
58.00
108.38
103.00
A
A
BB
85.87 98.00
80.75
77.00
108.00 59.88
91.00
SECTION A-A
154.50
80.75 70.00
142.00
78.13
59.88
SECTION B-B
58.00
77.00
59.88
91.00
FLOOR OF B9462 AND PIT
HIDDEN FOR INDIVIDUAL
CHAMBER DRAWINGS.
TOTAL INTERNAL DIMENSIONS
L: 154.50 " W: 108.00 " H: 98.00 "
USABLE INTERNAL SPACE
L: 154.50 " W: 80.75 " H: 85.87 "
USABLE INTERNAL SPACE IS
DEFINED AS LARGEST SPACE
WITHIN CHAMBER WITHOUT
INTERFERING WITH CHAMBER
COMPONENTS INCLUDING
PLENUM AND BLOWER.
A A
B B
9462 TRIPLE
CHAMBER
DO NOT SCALE DRAWING SHEET 2 OF 4
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:60 WEIGHT:
REV
B
SIZE
TITLE:
NAME DATE
COMMENTS:
REFER TO "CHAMBER MODELS.DOCX"
FOR NOTES ON MODEL AND DRAWING.
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH BEND
TWO PLACE DECIMAL
THREE PLACE DECIMAL
APPLICATION
USED ONNEXT ASSY
CHAMBER A
58.00 161.00
108.38
103.00
CC
D
D
60.00
78.00 91.00
59.88
59.88
78.13
80.75
155.00
108.00
SECTION C-C
80.75 108.00
85.87
78.00
60.00
59.88
88.00 98.00
SECTION D-D
FLOOR OF B9462 AND PIT
HIDDEN FOR INDIVIDUAL
CHAMBER DRAWINGS.
TOTAL INTERNAL DIMENSIONS
L: 155.00 " W: 108.00 " H: 98.00 "
USABLE INTERNAL SPACE
L: 155.00 " W: 80.75 " H: 85.87 "
USABLE INTERNAL SPACE IS
DEFINED AS LARGEST SPACE
WITHIN CHAMBER WITHOUT
INTERFERING WITH CHAMBER
COMPONENTS INCLUDING
PLENUM AND BLOWER.
A A
B B
9462 TRIPLE
CHAMBER
DO NOT SCALE DRAWING SHEET 3 OF 4
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:60 WEIGHT:
REV
B
SIZE
TITLE:
NAME DATE
COMMENTS:
REFER TO "CHAMBER MODELS.DOCX"
FOR NOTES ON MODEL AND DRAWING.
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH BEND
TWO PLACE DECIMAL
THREE PLACE DECIMAL
APPLICATION
USED ONNEXT ASSY
CHAMBER B
161.50
103.00
58.00 F
F
EE
91.00
59.88
108.00 80.75
85.87
59.88
98.00
SECTION F-F
154.50
108.00 80.75
SECTION E-E
FLOOR OF B9462 AND PIT
HIDDEN FOR INDIVIDUAL
CHAMBER DRAWINGS.
TOTAL INTERNAL DIMENSIONS
L: 155.00 " W: 108.00 " H: 98.00 "
USABLE INTERNAL SPACE
L: 155.00 " W: 80.75 " H: 85.87 "
USABLE INTERNAL SPACE IS
DEFINED AS LARGEST SPACE
WITHIN CHAMBER WITHOUT
INTERFERING WITH CHAMBER
COMPONENTS INCLUDING
PLENUM AND BLOWER.
A A
B B
9462 TRIPLE
CHAMBER
DO NOT SCALE DRAWING SHEET 4 OF 4
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:60 WEIGHT:
REV
B
SIZE
TITLE:
NAME DATE
COMMENTS:
REFER TO "CHAMBER MODELS.DOCX"
FOR NOTES ON MODEL AND DRAWING.
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH BEND
TWO PLACE DECIMAL
THREE PLACE DECIMAL
APPLICATION
USED ONNEXT ASSY
CHAMBER C
| OUTSIDE |
| Drawing View1 |
| Drawing View2 |
| Drawing View4 |
| Drawing View5 |
| CHAMBER A |
| Drawing View6 |
| Section View A-A |
| Section View B-B |
| Drawing View12 |
| CHAMBER B |
| Drawing View13 |
| Drawing View16 |
| Section View C-C |
| Section View D-D |
| CHAMBER C |
| Drawing View19 |
| Drawing View22 |
| Section View F-F |
| Section View E-E |
File details come from the government source that posted it. Updated .