About this file

The document is a Requirements List for an Amplifier solicitation issued by the Naval Surface Warfare Center, Dahlgren Division (NSWCDD). The specific amplifier requirements include a frequency range of 33-36 GHz, 700W output power, 8% duty cycle, and air-cooled waveguide output connection with remote computer command functionality. Additional integrated features include an input isolator, reverse power protection, driver amplifier, power test points, Ethernet/IEEE-488 remote capabilities, and conformal PCB coating.

The solicitation (N0017826QC600) is a small business set-aside for commercial items using Simplified Acquisition Procedures with a firm fixed-price basis. Key procurement terms include TAA compliance, all-inclusive pricing covering shipping and freight to Dahlgren, VA, with no additional costs permitted after award. Payment terms are Net 30 via Electronic Funds Transfer (EFT), and offerors must be authorized resellers to quote. The opportunity is being processed through the Department of the Navy Naval Sea Systems Command.

View the file

Other files for this federal contract opportunity

Other files attached to AMPLIFIER, newest first.
File Type Posted
N0017826QC600 SF1449.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Description Quantity

· Frequency Range 33-36 GHz

· Output power 700W

· 8% Duty Cycle (Utilizing two each, MEC-3123S TWT)

· Output connection needs to be wave guide, air cooled, capable of having remote control of functionality through computer commands The above includes the following:

Input Isolator Standard Reverse Power Protection Standard Driver Amplifier for 0 dBm In Standard Forward & Reverse Power Test Point Included Ethernet/IEEE-488 Remote Included Conformal PCB Coating Included

Requirements List

MUST BE AN AUTHORIZED RESELLER TO QUOTE