Base Year
CHANGES TO THE LINE ITEMS ARE HIGHLIGHTED IN GREEN
DIVISION 2 - SITE WORK
| Item No. | Item of Work | Work | Normal | Non- |
| | Unit | Working | Working |
| GENERAL WORK | | Hours | Hours |
| G-1 | Protective Enclosures | |
| Install the following enclosure types in locations and to the extent directed by the Government (price includes supplying all material and labor to install and remove specified protection methods). | |
| a. | 6 MIL polyethylene suspended from the existing ceiling system and weights applied 4 ft. 0 in. O.C. at floor | SF |
| b. | 6 MIL polyethylene secured to wood studs @ 24 inches O.C. with top and bottom 2 in. X 4 in. wood plates | SF |
| c. | 1/2 inch gypsum wallboard secured (one side) to wood studs @ 24 inches O.C. joints taped (one coat compound). Provide hollow core wood access door (3 ft. 0 in. x 6 ft. 8 in.) where required. | SF |
DIVISION 4 - MASONRY
| Item No. | Item of Work | Work | Normal | Non- |
| | Unit | Working | Working |
| MASONRY | | Hours | Hours |
| B1 | Remove existing masonry partition (cinder block, hollow clay tile, brick) with or without plaster. Includes removal of any doors, windows, frames, and all electrical wiring within the partition to the nearest outlet/junction box; terminate and cap. | |
| a. | 6 inch thickness, 0 ft. to 10 ft. height | SF |
| b. | 6 inch thickness, above 10 ft. height | SF |
| c. | 8 inch thickness, 0 ft. to 10 ft. height | SF |
| d. | 8 inch thickness, above 10 ft. height | SF |
| e. | 12 inch thickness, 0 ft. to 10 ft. height | SF |
| f. | 12 inch thickness, 10 ft. 1 inch to 16 ft. height | SF |
| g. | 12 inch thickness, above 16 ft. height (applies only to that portion in excess of 16 ft. above floor) | SF |
| B2 | Furnish and install concrete block masonry partition, running bond with 8 inch high X 16 inch long units, including precast concrete lintels. | |
| a. | 6 inch thickness, 0 ft. to 10 ft. height | SF |
| b. | 8 inch thickness, 0 ft. to 10 ft. height | SF |
| c. | 8 inch thickness, above 10 ft. (applies only to that portion above 10 ft. in height) | SF |
| d. | 8 inch thickness, above 10 ft. height with 2 hr fire rating | SF |
| e. | 8 inch thickness, above 10 ft. with 2 hr fire rating (applies only to that portion above 10 ft. in height) | SF |
| f. | 12 inch thickness, 0 ft. to 10 ft. height | SF |
| g. | 12 inch thickness, above 10 ft. (applies only to that portion above 10 ft in height) | SF |
| h. | 12 inch thickness, 0 ft. to 10 ft. height with 2 hr fire rating | SF |
| i. | 12 inch thickness, above 10 ft. with 2 hr fire rating (applies only to that portion above 10 ft in height) | SF |
| B3 | Furnish and install standard select common brick masonry units, 8 inch long X 3 inch high X 4 inch wide, includes running bond and preparing openings for doors, windows, etc. | |
| a. | Up to 100 S.F. | SF |
| b. | 101 S.F. to 300 S.F. | SF |
| c. | 301 S.F. or more | SF |
| B4 | Furnish and install standard red brick masonry units, 8 inch long x 3 inch high x 4 inch wide, includes running bond and preparing openings for doors, windows, etc. | |
| a. | Up to 100 S.F. | SF |
| b. | 101 S.F. to 300 S.F. | SF |
| c. | 301 S.F. or more | SF |
| B5 | Furnish and install silicone waterproofing, two coats, sprayed on. | |
| a. | Up to 500 S.F. | SF |
| b. | 501 S.F. to 1500 S.F. | SF |
| c. | 1501 S.F. or more | SF |
B6 RESERVED
B7 RESERVED
B8 RESERVED
| B9 | Furnish and install ready mix concrete 3000 psi, including formwork, reinforcing, finishing of concrete, and site cleanup. | |
| a. | 1 to 7 c.y. | CY |
| b. | 8 to 21 c.y. | CY |
| c. | 22 or more c.y. | CY |
| B10 | Concrete fill or topping up to 3 inches in thickness, including preparation of excavation or existing slab, all necessary formwork and site cleanup. | |
| a. | 0 to 100 S.F. | SF |
| b. | 101 up to 300 S.F. | SF |
| c. | 301 up to 700 S.F. | SF |
| d. | 701 S.F. or more | SF |
DIVISION 8 - DOORS AND HARDWARE
| Item No. | Item of Work | Work | Normal | Non- |
| | Unit | Working | Working |
| DOORS AND FRAMES | | Hours | Hours |
D1 RESERVED
D2 RESERVED
D3 Furnish and install new solid core Dutch door (2/8 to 3/6 X 6/8 to 7/0 X 1-3/4 in.) with 12 inch wide wood shelf, including shelf supports and 4 each 4 1/2 inch X 4 1/2 ball bearing hinges. Door lock not included in this line item. EA
| D4 | Furnish and install new hollow core birch sliding pocket door (3/0 X 6/8 X 1 3/4 in.), including frame, sanitary casing, track, latch and all associated hardware. |
| EA | |
| D5 | Furnish and install new double doors (each 3/0 X 6/8 to 7/9 X 1 3/4 in.) includes hinges, astragal, and metal door frame (use hinge No. H-I from hardware schedule unless otherwise specified). | |
| a. | hollow core wood door (with hinge No. H‑IA) | EA |
| b. | solid core wood door | EA |
| c. | hollow metal door | EA |
| d. | "B" label fire rated frame and wood door | EA |
| e. | "B" label fire rated frame and metal door | EA |
| f. | "C" label fire rated frame and wood door | EA |
| g. | "C" label fire rated frame and metal door | EA |
| D6 | Install government-furnished frame and door (includes door lock, closer and hinges) 3/0 to 3/16 X 6/8 to 7/0 X 1 3/4 in. | |
| a. | hollow core wood door | EA |
| b. | solid core wood door | EA |
| c. | hollow metal door | EA |
| D7 | Install government-furnished door and hardware in existing frame size 3/0 to 3/6 X 6/8 to 7/0 X 1-3/4 inch. | |
| a. | hollow core wood door | EA |
| b. | solid core wood door | EA |
| c. | hollow metal door | EA |
D8 Furnish and install new metal door frame (for government-furnished door) size 3/0 to 3/6 X 6/8 to 7/0 X 1-3/4 in. Wall thickness varies. EA
| D9 | Install metal louver in door (includes cutting opening). See Specification Section 08200. | |
| a. | Government-furnished louver | EA |
| b. | Contractor furnished new louver (2 ft. 0 inch X 2 ft. 0 inch metal | EA |
| D10 | Prepare opening in existing partition to receive new single door and frame. Contractor to prime one coat and paint one coat. Includes all framing and patching. | |
| a. | Drywall partition (wood and metal studs) | EA |
| b. | Plaster partition (wood and metal studs) | EA |
| c. | Masonry partition | EA |
| D11 | Prepare opening in existing partition to receive new double doors and frame (contractor to prime one coat and paint one coat). Includes all framing and patching. | |
| a. | drywall partition (wood and metal studs) | EA |
| b. | plaster partition (wood and metal studs) | EA |
| c. | masonry partition | EA |
| D12 | Provide all labor and materials necessary to undercut or shave an existing door. | |
| a. | wood door | EA |
| b. | metal door | EA |
D13 RESERVED
D14 RESERVED
D15 RESERVED
DOOR HARDWARE
HARDWARE WILL BE NEGOTIATED AS A NON-SCHEDULE LINE ITEM
H1 RESERVED
H2 RESERVED
H3 RESERVED
H4 RESERVED
H5 RESERVED
H6 RESERVED
H7 RESERVED
H10 RESERVED
DIVISION 9 - FINISHES
| Item No. | Item of Work | Work Unit | Normal | Non- |
| | | Working | Working |
| | | Hours | Hours |
DRYWALL CONSTRUCTION
| W1 | Remove existing wood or metal stud drywall partition. This includes the removal of door(s), door frames, electrical outlets and switches, and all wiring back to next junction or outlet box. Furnish and install cap on box if required. Doors, door frames and hardware shall be either returned to the Government or removed from the premises as directed by the Government | |
| a. | thickness 6 inches, height up to 10 ft. L.F. | LF |
| b. | thickness 6 inches, height above 10 ft. (applies only to that portion above 10 ft.) | LF |
| W2 | Remove existing wood or metal stud plaster partition. This includes the removal of door(s), door frames, electrical outlet and switches, and all wiring back to next junction or outlet box. Furnish and install cap on box if required. Doors, door frames and hardware shall be either returned to the government or removed from the premises as directed by the Government. | |
| a. | thickness 6 inches, height up to 10 ft. | LF |
| b. | thickness 6 inches, height above 10 ft. (applies only to that portion above 10 ft.) | LF |
| W3 | Remove drywall from one side of wood or metal stud partition (for soundproofing with fiberglass batts). Furnish and install new drywall when soundproofing completed, includes prime one coat and paint one coat (fiberglass and its installation not included in this line item.) | | |
| a. | taped and compounded joints, height up to 10 ft. | LF | |
| b. | taped and compounded joints, height above 10 ft. (applies only to that portion above 10 ft.) | SF | |
| c. | batten strips at joints, height up to 10 ft. | LF | $98.25 |
| d. | batten strips at joints, height above 10 ft. (applies only to that portion above 10 ft.) | LF | |
W4 Remove existing wood or metal door and door frame from remaining drywall or masonry partition. Door, door frame and all hardware shall be either returned to the Government or removed from the premises as directed by the Government.
| a. | In drywall partition (wood or metal stud) | EA |
| b. | In masonry partition (cinder block, day tile, brick, etc) | EA |
| W5 | Remove door and door frame in existing partition and seal the opening to match the adjacent surface, and paint to match existing wall. Door, door frame and all hardware shall be either returned to the Government or removed from the premises as directed by the Government. | |
| a. | In drywall partition (wood or metal stud) | EA |
| b. | In masonry partition (cinder block, clay tile, brick, etc) | EA |
| c. | In plaster partition (wood or metal stud) | EA |
| W6 | Remove existing wood or metal stud vinyl covered wallboard partition. This includes the removal of door(s), door frames, electrical outlets and switches, and all wiring back to next junction or outlet box. Furnish and install cap on box if required. Doors, doorframes and hardware shall be either returned to the Government or removed from the premises as directed by the Government. Contractor shall carefully remove vinyl covered wallboard and place in storage as directed by the Government. | |
| a. | height up to 10 ft. | LF |
| b. | height above 10 ft. (applies only to that portion above 10 ft.) | SF |
W7 Remove existing bank tope partition. Contractor to return and/or place in storage all hardware, panels and miscellaneous parts as directed by the Government, includes making wall and floor repairs, spot painting wall and replacing damaged floor tile. LF
| W8 | Furnish all labor and material to install wood stud or metal drywall partition (gypsum board both sides of partition) includes cutting and framing openings for doors, windows, etc. Primer one coat and paint one coat; color specified by the Government. | |
| a. | joints taped and compounded, height up to 10 ft. | LF |
| b. | joints taped and compounded, height above 10 ft. (applies only to that portion above 10 ft. above floor) | SF |
| c. | batten strips at joints, height up to 10 ft. | LF |
| d. | batten strips at joints, height above 10 ft. (applies only to that portion above 10 ft. above floor) | SF |
W9 Furnish all labor and materials to install metal stud drywall partition (gypsum board both sides of partition), includes cutting and framing openings for doors, windows, etc. Prime one coat and paint one coat as specified by the Government.
| a. | joints taped and compounded, height up to 10 ft. | LF |
| b. | joints taped and compounded, height above 10 ft. (applies only to that portion above 10 ft.) | SF |
| c. | batten strips at joints, height up to 10 ft. | LF |
| d. | batten strips at joints, height above 10 ft. (applies only to that portion above 10 ft. above floor) | SF |
| e. | one hour fire rating, height up to 10 ft. | LF |
| f. | one hour fire rating, height above 10 ft. (applies only to that portion above 10 ft.) | SF |
| g. | two hour fire rating, height up to 10 ft. | LF |
| h. | two hour fire rating, height above 10 ft. (applies only to that portion above 10 ft.) | SF |
| W10 | Furnish all labor and materials to install metal stud drywall partition ( gypsum board on one side only), includes cutting and framing for doors, windows, etc. Prime one coat and paint one coat; color specified by the Government. | |
| a. | joints taped and compounded, height up to 10 ft. | LF |
| b. | joints taped and compounded, height above 10 ft. (applies only to that portion above 10 ft.) | SF |
| c. | batten strips at joints, height up to 10 ft. | LF |
| d. | batten strips at joints, height above 10 ft. (applies only to that portion above 10 ft.) | SF |
| e. | one hour fire rating, height up to 10 ft. | LF |
| f. | one hour fire rating, height above 10 ft. (applies only to that portion above 10 ft.) | SF |
| W11 | Furnish all labor and materials to install metal furring strip drywall partition (gypsum board on one side only), includes cutting and framing for doors, windows, etc. Prime one coat and paint one coat; color as specified by the Government | |
| a. | joints taped and compounded, height up to 10 ft. | LF |
| b. | joints taped and compounded, height above 10 ft. (applies only to that portion above 10 ft.) | SF |
| c. | batten strips at joints, height up to 10 ft. | LF |
| d. | batten strips at joints, height above 10 ft. (applies only to that portion above 10 ft.) | SF |
| e. | one hour fire rating, height up to 10 ft. | LF |
| f. | one hour fire rating, height above 10 ft. (applies only to that portion above 10 ft.) | SF |
| W12 | Furnish all labor and materials to install second layer of drywall over an existing wall (one side only). Includes cutting for windows, doors, etc. Prime one coat and paint one coat; color to be specified by the Government. | |
| a. | height up to 10 ft. | LF |
| b. | height above 10 ft. (applies only to that portion above 10 ft.) | SF |
| W13 | Furnish all labor and materials to install metal stud, vinyl covered drywall partition (vinyl covered gypsum board both sides of partition), includes cutting and framing for doors, windows, etc. and batten strips at joints. | |
| a. | contractor-furnished, vinyl covered drywall, height up to 10 ft. | LF |
| b. | contractor furnished, vinyl covered drywall, height above 10 ft. (applies only to that portion above 10 ft.) | SF |
| c. | government-furnished, vinyl covered drywall, height up to 10 ft. | LF |
| d. | government-furnished, vinyl covered drywall, height above 10 ft. (applies only to that portion above 10 ft.) | SF |
| W14 | Furnish labor and materials to install vinyl covered drywall on existing partition (glued to drywall, wood, or metal stud), includes batten strips and trim. | |
| a. | height up to 10 ft. | LF |
| b. | height above 10 ft. (applies only to that portion above 10 ft.) | SF |
| W15 | Install Government-furnished vinyl covered drywall on existing partition (glued to drywall, wood, or metal studs). Contractor to furnish all other materials. Includes installation of batten strips and trim. | |
| a. | height up to 10 ft. | LF |
| b. | height above 10 ft. (applies only to that portion above 10 ft.) | SF |
W16 RESERVED
W17 Furnish and install new 3/4 inch X 5 1/2 inch wood baseboard molding #2 pine. LF
W18 Furnish and install new 3/4 inch X 5 1/2 inch clear white pine shoe molding onto baseboard. LF
| W19 | Furnish and install pine crown molding. | |
| a. | 3/4 inch X 3/4 inch | LF |
| b. | 9/16 inch X 1 5/8 inch | LF |
| c. | 9/16 inch X 2 1/4 inch | LF |
| d. | 3/4 inch X 3 1/2 inch | LF |
| e. | 3/4 inch X 4 1/4 inch | LF |
W20 Install Government-furnished (3) piece chair rail. LF
W21 Install Government-furnished (1) piece executive chair rail. LF
W22 Furnish and install 3 1/2 inch thick fiberglass batt insulation in conjunction with partition soundproofing. SF
FINISHES
| F1 | Furnish and install vinyl and/or rubber cove base. | |
| a. | 4 inches high | LF |
| b. | 6 inches high | LF |
| F2 | Remove existing vinyl/rubber cove base, patch and finish to even surfaces. | |
| a. | 4 inches high | LF |
| b. | 6 inches high | LF |
| F3 | Furnish and install edging strips for floor tile. | |
| a. | beveled vinyl plastic | LF |
| b. | aluminum | LF |
| F4 | Furnish and install resilient floor tile. | |
| a. | RESERVED | |
| b. | 12 inch X 12 inch X 1/8 inch vinyl tile | SF |
| c. | RESERVED | |
| d. | 12 inch X 12 inch X 3/32 inch vinyl tile | SF |
F5 Remove resilient floor tile (includes patching floor). SF
| F6 | Remove broken glass and putty or sealant from metal or wood sash. Replace with new clear plate or float glass and sealant, using approved safety hooks on the exterior of the sash. | |
| a. | 3/16 inch thick glass | SF |
| b. | 3/16 inch thick tempered glass | SF |
| c. | 1/4 inch thick glass | SF |
| d. | 1/4 inch thick tempered glass | SF |
| e. | 1/4 inch thick wire glass | SF |
F7 Remove existing carpet, packing and tackless strips including cleanup and disposal of all debris. SY
F8 Remove existing carpeting that is glued to floor. This includes cleaning subsurface of all tackless glue and carpet backing. SY
| F9 | Install Government-furnished carpeting and/or padding. Contractor to supply tackless glue and carpet backing. | |
| a. | tackless strip installation | SY |
| b. | glued down installation | SY |
F10 Furnish and install carpet trim strip at doorways or other edges. LF
F11 Repair carpet where partitions were removed with Government-furnished carpet. LF
CARPET FINISHES
| F12 | BROADLOOP CARPET - Furnish all labor and material to remove existing carpet. Supply and install Broadloom carpet. Supply adhesive or stucco strip and move conventional furniture if necessary. Note: Moving of furniture does not include dismantle of conventional or system furniture. Desk and file cabinets must be empty. All electrical items must be disconnected. | |
| a. | 36 oz. pattern cut pile | SY |
| b. | 30 oz. pattern loop graphics | SY |
| c. | 30 oz. textured loop scroll pattern | SY |
| d. | 32 oz. textured loop scroll pattern | SY |
| e. | 28 oz. textured loop scroll pattern | SY |
| f. | 32 oz. patterned loop graphic | SY |
| g. | 38 oz. patterned cut and loop | SY |
| h. | 38 oz. solution dyed cut pile | SY |
| i. | 32 oz. textured loop graphic | SY |
| j. | 26 oz. textured loop pattern | SY |
| k. | 26 0z. multi-colored textured loop | SY |
| l. | 36 oz. patterned cut pile | SY |
| m. | 67 oz. patterned cut pile graphic | SY |
| n. | 28 oz. pattern loop | SY |
| o. | 28 oz. texture loop pattern | SY |
| p. | 30 oz. interloop pattern | SY |
| q. | 30 oz. pattern loop graphics | SY |
| r. | 32 oz. patterned textured loop | SY |
| s. | 30 oz. multi-color textured loop | SY |
| t. | 30 oz. pattern loop graphics | SY |
| u. | 32 oz. pattern texture loop | SY |
| v. | 26 oz. enhanced loop graphics | SY |
| w. | 28 oz. textured loop pile | SY |
| x. | 28 oz. interloop pattern | SY |
| y. | 26 oz. solid cut pile | SY |
| z. | 28 oz. solid cut pile | SY |
| aa. | 36 oz. solid cut pile | SY |
| ab. | 28 oz. level loop graphic | SY |
| ac. | 26 oz. level loop graphic | SY |
| ad. | 26 oz. multicolored loop graphics | SY |
| ae. | 28 oz. enhanced loop graphics | SY |
| af. | 26 oz. nylon staple soxony | SY |
| ag. | 28 oz. nylon continuous filament | SY |
| ah. | 26 oz. tusted broomloom dyed nylon solution/10 gauge | SY |
| ai. | 28 oz. tusted broomloom dyed nylon solution/10 gauge | SY |
F13 CARPET TILE (18” X 18 “ or 36” X 36”) Furnish all labor and material to remove existing carpet, supply and install carpet tile. Supply adhesive or stucco strip, move conventional furniture and lift systems furniture. NOTE: Moving of furniture does not include dismantle of conventional furniture. Desks and file cabinets must be empty. All electrical items must be disconnected. Course shall be minimum of 1 inch thickness.
| a. | 20 0z. textured patterned loop | SY |
| b. | 20 oz. textured twist loop | SY |
| c. | 26 oz. textured twist loop | SY |
| d. | 11 oz. textured patterned loop | SY |
| e. | RESERVED | |
| f. | RESERVED | |
| g. | RESERVED | |
| h. | RESERVED | |
| i. | 26 oz. textured patterned loop | SY |
| j. | 26 oz. accuflift patterned loop | SY |
| k. | RESERVED | |
| l. | Collins & Aikman Carpet tile 18” x 18” Nomad Kasba ER 3RS | SY |
| F14 | PADDING Supply and install carpet padding. | |
| a. | Scott Carlisle SL ½” 30 S.Y., bonded cushion | YD |
| b. | SCI Competitor 30 S.Y. , 62 oz. rubber cushion | YD |
| c. | Anchor 80500 Royal step III ½ “ , Bonded cushion 30 sy | YD |
| d. | RESERVED | |
| e. | Crest Syntex II 24 oz. 40 SY, Synthetic cushion | YD |
| F15 | STAIR TREAD Furnish all labor and materials to supply and install stair treads. | |
| a. | Johnsonite or equal 3’ rubber tread | EA |
| b. | Johnsonite or equal 4’ rubber tread | EA |
| c. | Johnsonite or equal 3’ vinyl tread | EA |
| d. | Johnsonite or equal 4’ vinyl tread | EA |
| F16 | Remove access/raised flooring, including pedestals associated with hardware, finish floor, etc. |
| a. | Remove and dispose of off-site |
| b. | Install new access/raised flooring with pedestals |
CEILINGS
| C1 | Remove existing suspended ceiling and suspension system, including all accessories (heights up to 10 ft.). | |
| a. | suspended lay-in tile | SF |
| b. | suspended plaster or drywall | SF |
| c. | acoustic tile stapled or cement | SF |
| d. | suspended acoustic tile in grid | SF |
| C2 | Remove existing suspended ceiling tile and suspension system, including all accessories (height above 10 ft.). | |
| a. | suspended lay in tile | SF |
| b. | suspended plaster or drywall | SF |
| c. | acoustic tile stapled or cemented | SF |
| d. | suspended acoustic tile in grid | SF |
C3 Furnish and install new 60 inch x 60 inch modular integrated acoustical ceiling system consisting of: main grid of 60 inch x 60 inch runners with one 30 inch x 60 inch flat acoustical lay-in tile unit and one 30 inch x 60 inch coffered tile unit with a 48 inch long, two lamp unit, including return air through the fixture. Junction is not included. See section 09500 of the specifications. SF
C4 Furnish and install new 60 inch X 6 inch modular integrated acoustical ceiling system consisting of: main grid of 60 inch X 60 inch runners with two 30 inch X 60 inch flat acoustical lay-in units. SF
| C5 | Install and connect government-furnished modular integrated acoustical ceiling system consisting of: main grid of 60 inch X 60 inch (or 62 inch X 62 inch) runners with 30 inch X 60 inch (or 31 inch X 62 inch) flat acoustical lay-in units. | | $10.27 |
| a. | height up to 10 ft. | SF | $37.50 |
| b. | height over 10 ft. | SF | |
| C6 | Furnish and install new 2 ft. X 4 ft. X 5/8 inch acoustical file and new direct hung exposed metal grid suspension system. | |
| a. | height up to 10 ft. | SF |
| b. | height over 10 ft. | SF |
| C7 | Furnish and install new 2 ft. X 4 ft. X 5/8 inch acoustical tile in existing grid system including removal and disposal of existing tile where required. | |
| a. | height up to 10 ft. | SF |
| b. | height over 10 ft. | SF |
| C8 | Furnish and install new 2 ft. X 2ft. X 5/8 inch acoustical tile and new direct hung exposed metal grid suspension system. Exposed to be black or white as ordered. | |
| a. | height up to 10 ft. | SF |
| b. | height over 10 ft. | SF |
| C9 | Furnish and install new 2 ft. X 2 ft. X 5/8 inch rabbetted edge acoustical tile and new direct hung exposed metal grid suspension system. Exposed grid to be black or white as ordered. | |
| a. | height up to 10 ft. | SF |
| b. | height over 10 ft. | SF |
| C10 | Furnish an install new 2 ft. X 4 ft. aluminum pan tile painted white with acoustical insulation pad in existing grid system, including removal and disposal of existing ceiling tile of any type. | |
| a. | height up to 10 ft. | SF |
| b. | height over 10 ft. | SF |
C11 RESERVED
| C12 | Furnish and install gypsum board ceiling on suspended metal furring system. Finish joint with tape and compound. | |
| a. | height up to 10 ft. | SF |
| b. | height over 10 ft. | SF |
| C13 | Furnish and install 1 ft. X 1 ft. X 5/8 inch acoustical tile in accessible concealed grid suspension system. | |
| a. | height up to 10 ft. | SF |
| b. | height over 10 ft. | SF |
C14 Furnish and install 1 ft. X 1 ft. X 5/8 inch acoustical tile on vertical wall or horizontal ceiling surfaces with adhesive. Includes metal trim at edges. SF
C15 Furnish all labor and material to preface/repair acoustical ceiling tile and/or suspension system in areas where partitions have been removed. SF
C16 Install government-furnished ceiling tiles in an existing grid system. Includes removal and disposal of existing tile where required. SF
| C17 | Furnish and install thermal or acoustical batts above ceiling. | |
| a. | 3 1/2 inches thick | SF |
| b. | 6 inches thick | SF |
DIVISION 9 - FINISHES
PLASTER & PAINT
| Item No. | Item of Work | Work | Normal | Non- |
| | Unit | Working | Working |
| REPAIRS | | Hours | Hours |
| P1 | Repair gypsum board cracks and/or joints, tape joints, spackle, and sand smooth. Apply one coat of sealer. | |
| a. | height up to 12 ft. | SF |
| b. | height above 12 ft. | SF |
| P2 | Remove existing defective gypsum board, patch with new gypsum board (including framing), tape joints, spackle, and sand smooth. Apply one coat of sealer. | |
| a. | height up to 12 ft. | SF |
| b. | height above 12 ft. | SF |
| P3 | Remove existing defective gypsum board, patch with new gypsum board, tape joints, spackle and sand smooth. Apply one coat of sealer. | |
| a. | height up to 12 ft. | SF |
| b. | height above 12 ft. | SF |
| P4 | Remove existing corner bead and install new metal corner bead, spackle and sand smooth. Apply one coat of sealer. | |
| a. | plaster wall | LF |
| b. | drywall | LF |
| P5 | Repair plaster cracks in excess of 1/16 inch wide (undercut all cracks and apply bonding agent). Apply one coat of sealer. | SF |
| a. | height up to 12 ft. | SF |
| b. | height above 12 ft. | SF |
| P6 | Remove and replace alligatored white coat (to be used where brown coat is solid and firmly adhered to lath). Apply bonding agent to brown coat before application of white coat. Apply one coat of sealer. (This line item shall be used for patching areas smaller then 10 square feet.) | |
| a. | height up to 12 ft. | SF |
| b. | height above 12 ft. | SF |
| P7 | Remove existing defective plaster and lath backing, replace with new lath, one brown coat (in the 3 coat system), one gypsum plaster scratch coat, and one finishing white coat. Apply one coat of sealer. | |
| a. | rock lath (2 coat system), height up to 12 ft. | SF |
| b. | rock lath (2 coat system), height above 12 ft. | SF |
| c. | metal lath (3 coat system), height up to 12 ft. | SF |
| d. | metal lath (3 coat system), height above 12 ft. | SF |
| P8 | Furnish and apply on existing base one brown coat (in the 3 coat system), one gypsum plaster scratch coat, and one finishing white coat. Apply one coat of sealer. | |
| WALLS | |
| a. | rock lath (2 coat system), height up to 12 ft. | SF |
| b. | rock lath (2 coat system), height above 12 ft. | SF |
| c. | metal lath (3 coat system), height up to 12 ft. | SF |
| d. | metal lath (3 coat system), height above 12 ft. | SF |
| e. | masonry walls (2 coat system), height up to 12 ft. | SF |
| f. | masonry walls (2 coat system), height above 12 ft. | SF |
| CEILINGS | |
| g. | rock lath (2 coat system) | SF |
| h. | metal lath (3 coat system) | SF |
PAINTING
| P9 | Furnish materials, prepare surfaces, and paint with brush or roller walls, ceilings, columns, and/or other miscellaneous flat surfaces of drywall or plaster. | |
| a. | primer - 1 coat, height up to 12 ft. | SF |
| b. | primer - I coat, height above 12 ft. | SF |
| c. | lusterless - 1 coat, height up to 12 ft. | SF |
| d. | lusterless - 1 coat, height above 12 ft. | SF |
| e. | semi-gloss -1 coat, height up to 12 ft. | SF |
| f. | semi-gloss - 1 coat, height above 12 ft. | SF |
| g. | gloss - 1 coat, height up to 12 ft. | SF |
| h. | gloss - 1 coat, height above 12 ft. | SF |
| P10 | Furnish materials, prepare surfaces, and paint with brush or roller shelves, cabinets, molding, window sash and trim, stair risers, doors and frames, and miscellaneous trim. | |
| a. | primer - 1 coat | SF |
| b. | lusterless - 1 coat | SF |
| c. | semi-gloss - 1 coat | SF |
| d. | gloss - 1 coat | SF |
| P11 | Furnish materials, prepare surfaces, and paint with brush only ornamental work, railings, grilles, and steel stairs. | |
| a. | primer - 1 coat | SF |
| b. | lusterless - 1 coat | SF |
| c. | semi-gloss - 1 coat | SF |
| d. | gloss - 1 coat | SF |
| P12 | Furnish materials, prepare surfaces, and paint with brush or roller ductwork, conduit, and piping (over 6 inches in diameter that is not included in wall, ceiling, or column surfaces). | |
| NOTE: Painting of wall or ceiling mounted ductwork, conduit, or piping under 6 inches in diameter shall be included in the surface they are affixed to. | |
| a. | primer - 1 coat, height up to 12 ft. | SF |
| b. | primer - 1 coat, height above 12 ft. | SF |
| c. | lusterless - 1 coat, height up to 12 ft. | SF |
| d. | lusterless - 1 coat, height above 12 ft. | SF |
| e. | semi-gloss - 1 coat, height up to 12 ft. | SF |
| f. | semi-gloss - 1 coat, height above 12 ft. | SF |
| g. | gloss - 1 coat, height up to 12 ft. | SF |
| h. | gloss - 1 coat, height above 12 ft. | SF |
| P13 | Furnish materials, prepare surfaces, and apply the finishes as indicated below. | |
| a. | clear varnish in finish as ordered - 1 coat | SF |
| b. | stain in finish as ordered - 1 coat | SF |
| c. | stain-varnish in finish as ordered - 1 coat | SF |
P14 Furnish, materials, prepare surfaces, and paint radiators (brush only). SF
P15 Paint by stenciling, alpha- or numeric- characters, in size, color, and/or finish as specified by the delivery order. Characters from 2 inches height to 6 inches high. SF
P16 Paint by freehand, alpha- or numeric- characters, in size, color and/or finish as specified by the delivery order. Characters from 2 inches high to 6 inches high. SF
P17 Furnish materials, prepare surfaces, and paint with a brush or roller concrete floors and stair risers. SF
| P18 | Furnish materials, prepare surfaces and install government-furnished vinyl wall covering. | |
| a. | height up to 12 ft. | SF |
| b. | height above 12 ft. | SF |
| P19 | Remove vinyl wall covering from plaster walls. Patch and prime coat the wall as necessary in preparation for painting. | |
| a. | height up to 12 ft. | SF |
| b. | height above 12 ft. | SF |
P20 Remove old paint or varnished finish from doors, frames, or other rim using a liquid paint remover. Includes up to 3 applications of remover. SF
| P21 | Furnish materials and strip surfaces to bare substrate. This line item is to only be used for preparation of the surfaces listed below that are beyond the scope of normal preparation (as specified in the General Conditions). | |
| a. | concrete or masonry, height up to 12 ft. | SF |
| b. | concrete or masonry, height above 12 ft. | SF |
| c. | plaster, height up to 12 ft. | SF |
| d. | plaster, height above 12 ft. | SF |
| e. | metal, height up to 12 ft. | SF |
| f. | metal, height above 12 ft. | SF |
| g. | wood or plywood, height up to 12 ft. | SF |
| h. | wood or plywood, height above 12 ft. | SF |
| P22 | Furnish labor and materials and prepare surfaces for airless spray painting using latex paint only. The contractor shall make all arrangements for providing the necessary fresh air to the area to be painted. All spray painting shall be done outside the normal working hours unless otherwise specified by the Building Manager. This line item is to be used for spray painting of office areas and other finished space (non-mechanical areas). | |
| a. | lusterless | SF |
| b. | semi-gloss | SF |
| c. | gloss | SF |
| d. | gloss for ductwork, conduit, and piping | SF |
| P23 | Furnish labor and materials and prepare surfaces for airless spray painting. This line item is to be used for spray painting of mechanical areas only. Surface preparation shall include covering all identification plates, pipe and equipment labels, gauges, and other equipment and vents as indicated by the Building Manager. The entire room will be painted, including but not limited to, walls, ceilings, windows and frames, doors and frames, vents, grills, registers, railings, ducts, pipes, columns, and partitions as directed. All ductwork, conduit, pipe and pipe covering will be painted identifying colors in accordance with ANSI Standard A13.1. The contractor shall make all arrangements for providing the necessary fresh air to the area to be painted. All spray painting shall be done outside normal working hours unless otherwise specified by the Building Manager. Re-lettering and/or re-banding of equipment, pipes, conduit, etc. shall be accomplished using line item no. P24. | |
| a. | lusterless | SF |
| b. | semi-gloss | SF |
| c. | gloss | SF |
| P24 | Furnish labor and materials to install self-sticking labels, banding tape, flow arrows, and/or markers on piping, as directed. | |
| a. | Pipe up to 3inch diameter-Label characters 1 inch to 2 inches high. | EA |
DIVISION 9 - FINISHES
| Item No. | Item of Work | Work | Normal | Non- |
| | Unit | Working | Working |
| | | Hours | Hours |
Q1 Furnish all labor and materials to remove existing ceramic or quarry tile from wall or floor surfaces. SF
Q2 Furnish all labor and materials to flash patch uneven or defective wall or floor surface areas prior to the installation of new tile. SF
| Q3 | Furnish and install ceramic tile cove base (color to match existing). | |
| a. | 4 1/4 inch X 4 1/4 inch high | LF |
| b. | 6 inch X 4 1/4 inch high | LF |
| Q4 | Furnish and install ceramic tile sanitary cove base (color to match existing). | |
| a. | 4 1/4 inch X 4 1/4 inch high | LF |
| b. | 6 inch X 4 1/4 inch high | LF |
| Q5 | Furnish and install ceramic tile bullnose trim (color to match existing). | |
| a. | 4 1/4 inch X 4 1/4 inch high | LF |
| b. | 6 inch X 4 1/4 inch high | LF |
| c. | pipe greater than 3 inch diameter - label characters 2 1/4 inches to 4 inches | EA |
| Q6 | Furnish and install ceramic floor tiles with non-slip abrasive surface. Tiles sizes: 1 inch X 1 inch, 1 inch X 2 inch, 2 inch X 2 inch. Tile size to be specified on delivery order (color to match existing). | |
| a. | single color | SF |
| b. | 2 color blend | SF |
| c. | 4 color blend | SF |
| Q7 | Furnish and install ceramic wall tiles (color to match existing). | |
| a. | 4 1/4 inch X 4 1/4 inch high | LF |
| b. | 6 inch X 4 1/4 inch high | LF |
| c. | 8 1/2 inch X 4 1/4 inch | LF |
| d. | 6 inch X 6 inch | LF |
Q8 RESERVED
Q9 RESERVED
Q10 RESERVED
| Q11 | Furnish and install quarry tile cove base (color to match existing). | |
| a. | 2 inch high, 1/2 inch thick | LF |
| b. | 5 inch high, 1/2 inch thick | LF |
| Q12 | Furnish and install quarry tile sanitary cove base (color to match existing). | |
| a. | 2 inch high, 1/2 inch thick | LF |
| b. | 5 inch high, 1/2 inch thick | LF |
| Q13 | Furnish and install quarry tile bullnose trim (color to match existing). | |
| a. | 4 inch X 4 inch X 1/2 thick | LF |
| b. | 6 inch X 6 inch X 1/2 thick | LF |
| Q14 | Furnish and install quarry floor tiles with non-slip abrasive surface (color to match existing). | |
| a. | 4 inch X 4 inch X 1/2 thick | LF |
| b. | 6 inch X 6 inch X 1/2 thick | LF |
| c. | 4 inch X 8 inch X 1/2 thick | LF |
Q15 Furnish and install quarry tile wainscot (color to match existing) - 6 inch X 6 inch X 1/2 inch thick SF
Q16 RESERVED
Q17 RESERVED
Q18 RESERVED
Q19 RESERVED
DIVISION ???????
| Item No. | Item of Work | Work | Normal | Non- |
| | Unit | Working | Working |
| | | Hours | Hours |
| NL 1. | FLASH PATCH WORK | |
| Provide all labor and materials to repair spalls and cracks in brick, block or concrete floors. | |
| a. | Less than 1000 SF | SF |
| b. | 1000-2500 SF | SF |
| c. | Over 2500 SF | SF |
| NL 2. | REMOVE ADHESIVE (FLOOR) | |
| Provide all labor and materials to remove all asbestos containing adhesive, cementitious or glue materials from planar surfaces down to the bare substrate. | |
| a. | under 100 SF | SF |
| b. | 100 to 500 SF | SF |
| c. | 500 to 1500 SF | SF |
| NL 3. | REMOVE METAL PARTITIONS | |
| Provide all labor to disassemble and remove metal partitions. | |
| a. | 5' high | SF |
| b. | 8' high and above | SF |
| NL 4. | PANELS (ACOUSTICAL) | |
| Provide all labor and materials to install sound attenuation panels (sound soak). | SF |
| NL 5. | LIGHT FIXTURES (BATTERY) | |
| Provide all labor and materials to install recessed battery packed ceiling light. | EA |
| NL 6. | RECIRCUIT LIGHTS | |
| Provide all labor and materials to recircuit ceiling light fixture. | |
| a. | two by four dropped ceiling | EA |
| b. | metal pan or spline ceiling | EA |
| NL 7. | RETROFIT FOUR LAMP RECESSED LIGHT FIXTURES | |
| Furnish and install electronic ballast, 3M Silverlux Reflector and two T-8 lamps and sockets | |
| a. | dimmable electronic ballast | EA |
| NL 8. | Furnish and install new 2'X 4' recessed light fixtures with electronic ballast, 3 M Silverlux Reflector and two T-8 lamps and sockets. | |
| a. | Dimmable electronic ballast | EA |
DIVISION 15 - MECHANICAL
| Item No. | Item of Work | Work | Normal | Non- |
| | Unit | Working | Working |
| | | Hours | Hours |
M1 Remove existing sheet metal ductwork, including terminals, diffusers, hangers and associated appurtenances. LF
| M2 | Furnish and install sheet metal ductwork with 1 inch sound lining, including hangers and fasteners. | |
| a. | 24 gauge | SF |
| b. | 22 gauge | SF |
| c. | 20 gauge | SF |
| M3 | Furnished and install sheet metal ductwork including hangers and fasteners. | |
| a. | 24 gauge | SF |
| b. | 22 gauge | SF |
| c. | 20 gauge | SF |
| M4 | Furnish and install insulated flexible duct, including hangers and fasteners and tapping into existing ductwork. | |
| a. | 6 inch diameter | LF |
| b. | 8 inch diameter | LF |
| c. | 10 inch diameter | LF |
| d. | 12 inch diameter | LF |
| M5 | Furnish and install uninsulated flexible duct, including hangers and fasteners and tapping into existing ductwork. | |
| a. | 6 inch diameter | LF |
| b. | 8 inch diameter | LF |
| c. | 10 inch diameter | LF |
| d. | 12 inch diameter | LF |
M6 RESERVED
| M7 | Furnish and install ceiling diffuser in grid system, 24 inch X 24 inch finished dimension, (0 900 CFM), with opposed blade volume damper. | |
| a. | 6 inch diameter | EA |
| b. | 8 inch diameter | EA |
| c. | 10 inch diameter | EA |
| d. | 12 inch diameter | EA |
| M8 | Furnish and install ceiling diffuser in grid system, 24 inch X 48 inch finished dimension, (0 900 CFM), with opposed blade volume damper. | |
| a. | 6 inch diameter | EA |
| b. | 8 inch diameter | EA |
| c. | 10 inch diameter | EA |
| d. | 12 inch diameter | EA |
| M9 | Furnish and install return air grilles and/or panel type diffusers in grid system, 24 inch X 24 inch finished dimension (0-1000 CFM). | |
| a. | 8 inch diameter | EA |
| b. | 10 inch diameter | EA |
| c. | 12 inch diameter | EA |
| d. | 14 inch diameter | EA |
| M10 | Furnish and install return air grilles and/or panel type diffusers in grid system, 24 inch X 48 inch finished dimension (0-1000 CFM). | |
| a. | 8 inch diameter | EA |
| b. | 10 inch diameter | EA |
| c. | 12 inch diameter | EA |
| d. | 14 inch diameter | EA |
| M11 | Furnish and install perforated plate in ceiling grid system (either supply or return). | |
| a. | 24 inch X 24 inch | EA |
| b. | 24 inch X 48 inch | EA |
| M12 | Furnish and install opposed blade volume damper in ductwork. | |
| a. | up to 150 sq. in. | EA |
| b. | 151 to 400 sq. in. | EA |
| c. | 401 to 800 sq. in. | EA |
| d. | 801 to 1300 sq. in. | EA |
| M13 | Furnish and install splitter damper with outside controller in main duct. | |
| a. | 200 to 400 sq. in. | EA |
| b. | 401 to 800 sq. in. | EA |
| c. | 801 to 1600 sq in. | EA |
M14 Furnish and install access door in ductwork. Up to 200 sq. in. ( 2 inch X 16 inch) EA
| M15 | Furnish and install fire damper in ductwork (curtain type). Curtain to be located outside of air stream. | |
| a. | up to 180 sq. ft. | EA |
| b. | 181 to 600 sq. ft. | EA |
| c. | 601 to 1300 sq. ft. | EA |
| d. | 1301 to 2400 sq. ft. | EA |
| M16 | Furnish and install lineal supply air diffuser consisting of minimum 6 slot (transverse) tee, air plenum with flexible hose inlet and adjustable ampere. | |
| a. | normal 5 ft. length - 4 inch minimum width | EA |
| b. | normal 6 ft. length - 4 inch minimum width | EA |
M17 Remove an existing ceiling diffuser or return air grille, and cap the opening at the main duct. EA
M18 Relocate an existing ceiling diffuser or return air grille, including capping the existing opening and tapping a new opening into the main duct. EA
| M19 | Provide all necessary labor and equipment to balance the following air systems. | |
| a. | centrifugal fan | EA |
| b. | heating and ventilating unit | EA |
| c. | in-line fan | EA |
| d. | propeller or wall fan | EA |
| e. | room exhaust fan | EA |
| f. | air-conditioning equipment, central station | EA |
| g. | built-up low pressure unit | EA |
| h. | built-up high pressure unit | EA |
| i. | multi-zone AC and heating unit (including one zone only ) | EA |
| j. | multi-zone AC and heating unit (each additional zone over zone ) | EA |
| k. | package A.G. unit | EA |
| l. | rooftop heating and cooling unit | EA |
| m. | supply or return exhaust registers and diffusers, height up to 10 ft. | EA |
| n. | supply or return exhaust registers and diffusers, height above 10 ft | EA |
M20 RESERVED
INSULATION
M21 Furnish and install board type fiberglass insulation (with foil reinforced Kraft vapor barrier) on ducts or other surfaces, 1 1/2 inch thickness, 3 Ibs. density. SF
M22 Furnish and install blanket type flexible fiberglass insulation (with foil reinforced Kraft vapor barrier) on ducts, tanks, etc., 1 1/2 inch thickness, 75 Ibs. density. SF
| M23 | Furnish and install insulation on boilers. | |
| a. | 1-1/2 calcium silicate (asbestos free), with 1/2 cement finish | SF |
| b. | 2 inch fiberglass | SF |
| M24 | Furnish and install insulation on breeching using 2 inches of calcium silicate (asbestos free), with 1/2 inch cement finish. | |
| a. | rectangular | SF |
| b. | round | SF |
M25 Furnish and install insulation finish using 1/2 inch cement over 1 inch wire mesh, including comer bead. SF
| M26 | Furnish and install fiberglass insulation on existing piping, including elbows and expansion joints. | |
| HEIGHT UP TO 12 FEET | |
| a. | up to 1 3/4 inch | LF |
| b. | 2 inch | LF |
| c. | 3 inch | LF |
| d. | 4 inch | LF |
| e. | 5 inch | LF |
| f. | 6 inch | LF |
| g. | 8 inch | LF |
| h. | 10 inch | LF |
| i. | 12 inch | LF |
| j. | 14 inch | LF |
| k. | 16 inch | LF |
| l. | 18 inch | LF |
| m. | 20 inch | LF |
| HEIGHT GREATER THAN 12 FT & UP TO 20 FT | |
| n. | up to 1 3/4 inch | LF |
| o. | 2 inch | LF |
| p. | 3 inch | LF |
| q. | 4 inch | LF |
| r. | 5 inch | LF |
| s. | 6 inch | LF |
| t. | 8 inch | LF |
| u. | 10 inch | LF |
| v. | 12 inch | LF |
| w. | 14 inch | LF |
| x. | 16 inch | LF |
| y. | 18 inch | LF |
| z. | 20 inch | LF |
| M27 | Furnish and install fiberglass insulation and service jackets on pipe flanges, valves, or other service fittings. | |
| a. | up to 1 3/4 inch | LF |
| b. | 2 inch | LF |
| c. | 3 inch | LF |
| d. | 4 inch | LF |
| e. | 5 inch | LF |
| f. | 6 inch | LF |
| g. | 8 inch | LF |
| h. | 10 inch | LF |
| i | 12 inch | LF |
| j. | 14 inch | LF |
| k. | 16 inch | LF |
| l | 18 inch | LF |
| m. | 20 inch | LF |
| HEIGHT GREATER THAN 12 FT & UP TO 20 FT | |
| n. | up to 1 3/4 inch | LF |
| o. | 2 inch | LF |
| p. | 3 inch | LF |
| q. | 4 inch | LF |
| r. | 5 inch | LF |
| s. | 6 inch | LF |
| t. | 8 inch | LF |
| u.. | 10 inch | LF |
| v. | 12 inch | LF |
| w. | 14 inch | LF |
| x. | 16 inch | LF |
| y. | 18 inch | LF |
| z. | 20 inch | LF |
| M28 | Furnish and install 1-inch thick flexible unicellular insulation on new or existing piping systems, including all elbows, fittings, valves, etc. | |
| HEIGHT UP TO 12 FEET | |
| a. | 1/2 inch pipe size | LF |
| b. | 3/4 inch pipe size | LF |
| c. | 1 inch pipe size | LF |
| d. | 1 1/4 inch pipe size | LF |
| HEIGHT GREATER THAN 12 FEET AND UP TO 20 FEET | |
| e. | 1/2 inch pipe size | LF |
| f. | 3/4 inch pipe size | LF |
| g. | 1 inch pipe size | LF |
| h. | 1-1/4 inch pipe size | LF |
M29 Fireproof metal deck and I-beams. SF
DIVISION 16 - ELECTRICAL
| Item No. | Item of Work | Work | Normal | Non- |
| | Unit | Working | Working |
| GENERAL WORK | | Hours | Hours |
| E1 | Remove existing lighting fixtures (all sizes and types of interior lights). Includes disconnecting and removal of wire, raceway or cable to nearest junction or outlet box. Furnish and install cover on outlet box where wiring is removed. | |
| a. | fixture stored on premises as directed by Ordering Official | EA |
| b. | fixture removed from premises | EA |
| E2 | Disconnect and remove telephone/power pole to include removal of power supply wiring and raceway to nearest junction or outlet box. Furnish and install cover on outlet box where wiring is. | |
| a. | pole stored on premises as directed by the Ordering Official | EA |
| b. | pole removed from premises | EA |
| E3 | Disconnect and remove existing electrical conductors from raceway. 600 volt wiring maximum, per linear foot, per conductor. | |
| a. | #10, 12 AWG | LF |
| b. | #10, 8 AWG | LF |
| c. | #6, 4 AWG | LF |
| d. | #3, 2 AWG | LF |
| e. | #0, 00 AWG | LF |
| f. | #000, 000 AWG | LF |
| E4 | Disconnect and remove existing thin wall conduit, rigid conduit, flexible conduit, armored or unarmored cable, surface raceway, i.e., wiremold, pancake molding, etc., include hangers, braces, straps, boxes and fittings (surface mounted and | |
| a. | 1/2 inch thru 3/4 inch diameter | LF |
| b. | 1 inch thru 1 1/2 inch diameter | LF |
| c. | 2 inch thru 2 1/2 inch diameter | LF |
| d. | 3 inch thru 4 inch diameter | LF |
| E5 | Disconnect and remove existing service fitting from under floor duct system. Furnish and install blank cap to match existing (may require return trip). Contractor to store material for possible | |
| a. | electrical service fitting, including wires back to feed sc | EA |
| b. | telephone service fitting | EA |
E6 Disconnect and remove existing wall outlet or light switch and install blank cover plate. EA
| E7 | Furnish, install and secure thin wall conduit (EMT) to include fittings, connectors, bends, supports, hangers, conduits, pull boxes, and outlet junction boxes, not to exceed 4 11/16 in X 2 1/8 inch. | |
| a. | 1/2 inch diameter | LF |
| b. | 3/4 inch diameter | LF |
| c. | 1 inch diameter | LF |
| d. | 1 1/4 inch diameter | LF |
| e. | 1 1/2 inch diameter | LF |
| f. | 2 inch diameter | LF |
| g. | 2 1/2 inch diameter | LF |
| h. | 3 inch diameter | LF |
| i. | 4 inch diameter | LF |
| E8 | Furnish, install and secure rigid steel conduit to include fittings, connectors, bends, supports, hangers, conduits, pull boxes and outlet/junction boxes, not to exceed 4 11/16 inch X 2 1/8 inch. | |
| a. | 1/2 inch diameter | LF |
| b. | 3/4 inch diameter | LF |
| c. | 1 inch diameter | LF |
| d. | 1 1/4 inch diameter | LF |
| e. | 1 1/2 inch diameter | LF |
| f. | 2 inch diameter | LF |
| g. | 2 1/2 inch diameter | LF |
| h. | 3 inch diameter | LF |
| E9 | Furnish, install and secure flexible metal conduit, including fittings, connectors, and outlet/junction boxes, not to exceed 4 11/16 inch X 2 1/8. | |
| a. | 1/2 inch diameter | LF |
| b. | 3/4 inch diameter | LF |
| c. | 1 inch diameter | LF |
| d. | 1 1/4 inch diameter | LF |
| e. | 1 1/2 inch diameter | LF |
| f. | 2 inch diameter | LF |
| g. | 2 1/2 inch diameter | LF |
| h. | 3 inch diameter | LF |
| i. | 4 inch diameter | LF |
| E10 | Furnish, install and secure liquid tight flexible conduit, including fittings, connectors, supports and outlet/junction boxes, not to exceed 4 11/16 inch X 2 1/8 inch maximum. | |
| a. | 1/2 inch diameter | LF |
| b. | 3/4 inch diameter | LF |
| c. | 1 inch diameter | LF |
| d. | 1 1/4 inch diameter | LF |
| e. | 1 1/2 inch diameter | LF |
| f. | 2 inch diameter | LF |
| g. | 2 1/2 inch diameter | LF |
| E11 | Furnish and install plates on existing receptacles. | |
| a. | single gang receptacle or switch plate | EA |
| b. | two gang receptacle or switch plate | EA |
| c. | three gang receptacle or switch plate | EA |
| E12 | Furnish, install and connect outlet box for use with armored cable, EMT, flexible conduit, liquid tight flexible conduit, rigid conduit or surface raceway. Box to be surface or recess mounted, adequate size for specified wiring device and maximum number of wires as allowed. | |
| See NEMA CONFIGURATIONS (Found in Specifications Section 16050) | |
| a. | single pole 20A switch | EA |
| b. | three-way 20A switch | EA |
| c. | receptacle duplex 15A, 2 pole, 3 wire, 125V, NEMA 5-15 | EA |
| d. | receptacle duplex 20A, 2 pole, 3 wire, 125V, NEMA 5-15 | EA |
| e. | receptacle duplex 20A, 2 pole, 3 wire, 125V, NEMA 5 20R, isolated grounded wall outlet | EA |
| f. | receptacle duplex 20A, 2 pole, 3 wire, 250V, NEMA 6- | EA |
| g. | receptacle single 20 A, 3 pole, 4 wire, 125/250V, NEMA 1420 | EA |
| h. | receptacle single 20A, 4 pole, 4 wire, 120/208V, NEMA 18-20 | EA |
| i. | receptacle single 30A, 2 pole, 3 wire, 250V, NEMA 5-: | EA |
| j. | receptacle single 30A, 3 pole, 4 wire, 125/250V, NEMA 14-30 | EA |
| k. | receptacle single 30A, 4 pole, 4 wire, 120/208V, NEMA 18-30 | EA |
| l. | dedicated receptacle 20 or 30A, up to 75 LF | EA |
| E13 | Disconnect and remove existing 2 wire, 15/20 ampere, 120 volt outlet. Furnish, install, and connect new NEMA (ANSI) 5-15 or 5-20 general purpose receptacle, complete with new plastic (brown) plate. No wire included. Assurance of | |
| a. | single | EA |
| b. | duplex | EA |
| E14 | Furnish and install in raceway system, copper electrical conductors. Per linear foot per conductor. To include connectors, terminals, lugs and insulators. 600 V maximum, solid to #10 AWG, larger sizes stranded. | |
| a. | #12 AWG THW insulation | LF |
| b. | #12 AWG THHN insulation | LF |
| c. | #10 AWG THW insulation | LF |
| d. | #10 AWG THHN insulation | LF |
| e. | #8 AWG THW insulation | LF |
| f. | #8 AWG THHN insulation | LF |
| g. | #6 AWG THW insulation | LF |
| h. | #6 AWG THHN insulation | LF |
| i. | #4 AWG THW insulation | LF |
| j. | #4 AWG THHN insulation | LF |
| k. | #2 AWG THW insulation | LF |
| l. | #2 AWG THHN insulation | LF |
| m. | #0 AWG THHN insulation | LF |
| n. | #2/0 AWG THHN insulation | LF |
| o. | #3/0 AWG THHN insulation | LF |
| p. | #4/0 AWG THHN insulation | LF |
| E15 | Furnish, install and connect type (AC) armored flexible cable (BX with ground) in new partitions and dropped ceilings, including connections (mechanical & electrical), fittings supports. | |
| a. | 12-02 | LF |
| b. | 12-03 | LF |
| c. | 12-04 | LF |
| d. | 10-04 | LF |
| e. | 10-05 | LF |
| f. | 10-06 | LF |
| E16 | Furnish, install, and connect type (AC) armored flexible cable (BX with grouncl4 in existing partitions and dropped ceilings, including connections (mechanical and electrical), fittings, supports, straps, and insulators . | |
| a. | 12-02 | LF |
| b. | 12-03 | LF |
| c. | 12-04 | LF |
| d. | 12-05 | LF |
| e. | 12-06 | LF |
| f. | 12-07 | LF |
| E17 | Furnish and install surface metal raceway, including all fittings, couplings, connectors, straps, adapters. When wiring is required, line item E14 must be included on the order. | |
| a. | approximately 3/4 inch wide X 21/32 inch high (ex. wiremold cat. 700 or equal) | LF |
| b. | approximately 3/4 inch wide X 1 3/4 inch high complete with base and cover (ex. Wiremold cat. G- | LF |
| c. | approximately 4 3/4 inch wide X 1 3/4 inch high complete with base and cover (ex. Wiremold cat. G 4000 or equal with or without dividers) | LF |
| d. | approximately 1 9/16 inch wide X 11/32 inch high (ex. Wiremold cat 1500 or equal) | LF |
| e. | approximately 4 3/4 inch X 3 9/16 inch high complete with base and cover (ex. Wiremold G-6000 or equal) | LF |
| E18 | Furnish, install, and connect into raceway system (EMT, flexible, liquidtight, rigid) a NEMA 1galvanized junction box complete with a screw type cover and supports. | |
| a. | 6 inch X 6 inch X 4 inch | EA |
| b. | 8 inch X 8 inch X 4 inch | EA |
| c. | 12 inch X 12 inch X 6 inch | EA |
| d. | 18 inch X 18 inch X 6 inch | EA |
| e. | 18 inch X 18 inch X 8 inch | EA |
| f. | 24 inch X 24 inch X 8 inch | EA |
| g. | 24 inch X 24 inch X 12 inch | EA |
| h. | 36 inch X 36 inch X 12 inch | EA |
| E19 | Furnish, install and connect under floor outlet fittings with duplex receptacle or telephone service fitting into existing insert. Fitting shall match those existing in the building. If wiring is required, line item E 14 must be included on the order. | |
| a. | duplex receptacle and fitting | EA |
| b. | telephone outlet fitting | EA |
| c. | duplex receptacle and fitting with isolated ground | EA |
E20 Furnish and install under floor outlet fitting with 3 or 5 Ampherol connector service fitting into existing insert. Fitting shall match existing in the building where work is to be performed. EA
| E21 | Furnish, install and connect under floor outlet fitting into existing insert to match existing in building (wire not included). If wire is required, line item number E14 must be added to order. | |
| a. | double duplex receptacles | EA |
| b. | double duplex receptacle with isolated ground | EA |
E22 Furnish and install after set insert in under floor duct system to include removal of material to gain access to raceway. Note, if fitting is required, line item number E19, E20, or E21 must be added to order. EA
| E23 | Core drilling reinforced concrete (not to include beams and columns) to 6 inches thick. (The contractor shall locate reinforcing prior to drilling.) No reinforcing shall be cut. The Building Manager shall approve location of core prior to drilling. All holes shall be fire stopped. | |
| a. | 1 inch diameter, up to 6 inches thick | EA |
| b. | 1 inch diameter, each additional inch in thickness over 6 inches | EA |
| c. | 1 1/2 inch diameter, up to 6 inches thick | EA |
| d. | 1 112 inch diameter, each additional inch in thickness over 6 inches | EA |
| e. | 2 inch diameter, up to 6 inches thick | EA |
| f. | 2 inch diameter, each additional inch in thickness over 6 inches | EA |
| g. | 3 inch diameter, up to 6 inches thick | EA |
| h. | 3 inch diameter, each additional inch in thickness over 6 inches | EA |
| i. | 6 inch diameter, up to 6 inches thick | EA |
| j. | 6 inch diameter, each additional inch in thickness over 6 inches | EA |
| E24 | Masonry rotary drilling. Rotary drill clay hollow tile, brick, or cinder block wall. All holes shall be fire stopped. | |
| a. | 2 inch diameter, up to 8 inches thick | EA |
| b. | 2 inch diameter, each additional inch in thickness over 8 inches | EA |
| c. | 4 inch diameter, up to 8 inches thick | EA |
| d. | 4 inch diameter, each additional inch in thickness over 8 inches | EA |
| e. | 6 inch diameter, up to 8 inches thick | EA |
| f. | 6 inch diameter, each additional inch in thickness over 8 inches | EA |
| g. | 8 inch diameter, up to 8 inches thick | EA |
| h. | 8 inch diameter, each additional inch in thickness over 8 inches | EA |
| E25 | Furnish, install, and connect fusible single throw general duty safety switch, complete with time delay fuses up to maximum ampacity of switch. | |
| a. | 2 wire solid neutral, 30A, 1 cartridge fuse 120V | EA |
| b. | 3 wire solid neutral, 30A, 2 cartridge fuses, 120/240V | EA |
| c. | 3 wire solid neutral, 60A, 2 cartridge fuses, 120/240V | EA |
| d. | 4 wire solid neutral, 30A, 3 cartridge fuses, 241)V | EA |
| e. | 4 wire solid neutral, 60A, 3 cartridge fuses, 240V | EA |
| f. | 4 wire solid neutral, 100A, 3 cartridge fuses, 240V | EA |
| g. | 4 wire solid neutral, 200A, 3cartridge fuses, 2 40V | EA |
| E26 | Furnish, install and connect fusible single throw heavy duty safety switch, complete with time delay fuses up to the ampacity of the switch. | |
| a. | 4 wire solid neutral, 30A, 3 cartridge fuses 277/480V | EA |
| b. | 4 wire solid neutral, 60A, 3 cartridge fuses 277/480V | EA |
| c. | 4 wire solid neutral, 100A, 3 cartridge fuses 277/480V | EA |
| E27 | Disconnect and remove safety switch panel, surface mounted or recessed. | |
| a. | 30A to 60A safety switch | EA |
| b. | 100A safety switch | EA |
| c. | 200A safety switch | EA |
| E28 | Furnish and install telephone/power pole 2-314 inch X 1-7116 inch with 2 duplex, 15A, 125V, receptacles, complete with 2-118 inch high feed end, fixed stanchion, and hanger clamp assembly. For wiring use applicable line item(s) to provide power supply. | |
| a. | pole height 10 ft. 5 inches | EA |