0621-04 - Canopy - Specs.xlsx
XLSX spreadsheet 17 KB Posted
- Attached to
- CANOPY Federal contract opportunity
- Solicitation number
- N0017824Q6912
About this file
This document contains the specifications for a canopy to be procured by the Naval Sea Systems Command (NAVSEA) under Solicitation Number N0017824Q6912. The canopy is required to provide cover and insulation from the sun and weather to shield engineering teams working below. It must be a 4 or 6 post design, able to abut the side of an existing building without attaching to it, and cover a concrete pad approximately 23' x 16' at a minimum height of 10 feet. The canopy must be designed to resist the snow and wind loads of the Dahlgren, VA area and be colored white. The government will be responsible for assembly, installation, and integration of the provided canopy hardware. Offers are due by 12:00 PM EST on August 1, 2024, and award will be made on a Lowest Price Technically Acceptable basis to a small business registered in the System for Award Management (SAM).
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| CDRL A001_Redacted.pdf | ||
| N0017824Q6912 SF1449.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Specifications | |
| Description | Quantity |
| Canopy | 1 |
| Canopy shall include: | |
| Engineering drawings stamped by professional engineer accredited in the state of VA (See attached CDRL) | |
| All hardware necessary for installation and construction | |
| Installation instructions if not contained within the engineering drawings | |
| Canopy shall provide cover and insulation from the sun and weather to shield engineering teams working below. | |
| Canopy installation services shall not be provided. The government shall be responsible for assembly, installation, and integration of provided canopy hardware. | |
| Canopy may be a 4 post or 6 post design. | |
| Canopy shall abut the side of an existing building but shall not interface with or attach structurally to said building located at 6443 Jarret’s PL, Dahlgren, VA, 22448 | |
| Canopy shall be designed to cover a concrete pad approximately 23’ in length and 16’ in depth at a minimum height of 10 feet. The Canopy should be sloped to shed water and meet the existing roofline at a height of approximately 11’. | |
| Canopy shall be colored white | |
| Canopy may fasten to existing concrete floor or may be designed with new concrete footings | |
| Canopy shall be designed to resist the snow and wind loads of the area in which it is installed. |
File details come from the government source that posted it. Updated .