0505-01 (036-B55) - HF Test Set - Specs.xlsx

XLSX spreadsheet 12 KB Posted

Attached to
HF Test Set
Solicitation number
N0017821Q6871
Issued by

View the file

Other files

File Type Posted
SF18 - Final.pdf PDF
N0017821Q6871 Synopsis.doc DOC document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

REQUIREMENTS LIST
ItemDescriptionQuantity
0001Portable HF Test Set1
0002Shipping to Dahlgren, VA 224481
Minimum Specifications:
Application:This equipment must be portable and designed for shipboard use.
Weight:Maximum not to exceed 100 lb
Size:Maximum 2’x2’x2’
Effective Isotropic Radiated Power EIRP:100 W continuous-wave (no pulsed or modulation) or 50 dBm with 0 dBi antenna gain so 50 dBm EIRP for each tone. 53 dBm total EIRP
Tones:50 dBm; Two tones at a time; 2.24/4.94, 5.20/8.66, and 11.64/14.82 MHz. Each of those two pairs must be simultaneous.
Eqpt. Transmitting Cap.:Two 100 W continuous-wave radiofrequency tones
Frequencies transmitted in following pairs: 2.24/4.94 MHz, 5.20/8.66 MHz, and 11.64/14.82 MHz
Transmitters will be filtered to ensure only desired frequency pairs are emitted; all other signals must be at least 60 dB below the fundamentals
Equipment Must Include:One or more transmit antennas with at least 0 dBi of gain at specified frequency pairs; omni-directional antenna is acceptable
One or more receive antennas with at least 0 dBi of gain at specified frequency pairs; directional antenna is desired
Through filters or other frequency selective design, receive setup shall:
· Reject fundamental frequency pairs by at least 60 dB
· Minimize filtering of non-fundamental frequencies
All antennas, filters, cabling, and connectors required to meet technical performance specifications.
Intermodulation and harmonic requirement -60dBc

File details come from the government source that posted it. Updated .