03-1N1304 Boiler System Replacement with Associated Utility Work.pdf

PDF 873 KB Posted

Attached to
03-1N1304 Boiler System Replacement with Associated Utility Work
Solicitation number
03-1N1304
Issued by
El Dorado County, California

About this file

This is a Notice to Bidders and Special Provisions document from the California Department of Transportation for a boiler system replacement project with associated utility work at the Kyburz Maintenance Station in El Dorado County. The project involves removal of an existing boiler and controller and installation of new mechanical and electrical equipment in an equipment storage building. Bids are due on Tuesday, December 15, 2026, at 2:00 p.m. via the Bid Express website. The work must be completed within 90 to 125 working days as bid by the contractor. The estimated project cost is $1,120,000. Contractors must hold either a Class A license or a Class C-4 license. The project includes bid items for time-related overhead, job site management, water pollution control program, temporary erosion control measures, and building work. Special provisions address fire safety requirements, environmental compliance, small business enterprise participation goals, prevailing wage requirements, and detailed mechanical specifications for boiler installation, piping systems, valves, and related equipment.

The bid requires a bidder's security deposit equal to at least 10 percent of the bid amount. The Department has established a Disabled Veteran Business Enterprise (DVBE) contract goal of 3 percent and a Small Business Enterprise (SBE) participation goal of 5 percent. This is a non-federal-aid contract subject to California prevailing wage requirements, with general prevailing wage rates available through the California Department of Industrial Relations. Bidders may request either a small business preference (available to certified SBEs offering a 5 percent bid reduction or $50,000, whichever is less) or a non-small business subcontractor preference (requiring commitment to subcontract at least 25 percent to certified SBEs). The Department provides a California company preference for bid comparison purposes. All SBEs must be certified by 5:00 p.m. on the bid opening date. The project is located in a freeze-thaw area with specific environmental and fire safety protocols required, including site safety plan approval by the State Fire Marshal before work begins. Final reports on SBE utilization must be submitted within 10 days of contract acceptance.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bids open Tuesday, December 15, 2026 Dated November 16, 2026 OSD

STATE OF CALIFORNIA

DEPARTMENT OF TRANSPORTATION

NOTICE TO BIDDERS

AND

SPECIAL PROVISIONS

FOR BUILDING CONSTRUCTION IN EL DORADO COUNTY AT THE KYBURZ

MAINTENANCE STATION AT 13561 EL DORADO FREEWAY

In District 03 On Route 5712

Under Bid book dated November 16, 2026 Standard Specifications dated 2026

Project plans approved October 20, 2026 Standard Plans dated 2026

Identified by Contract No. 03-1N1304

03-ED-5712

Project ID 0324000303

SPECIAL NOTICES

• See sections 2 and 3 for contractors' registration requirements.

• The Department advises bidders that potential claim records must be submitted by the contractor using the Department's Internet potential claim system.

• See section 2 for submittal requirements for DVBE quotes and Non–Small Business

Subcontractor Preference.

• For work plan for local material from (1) a noncommercial source or (2) a source not regulated under California jurisdiction, see section 6-1.03B(2).

• See section 7-1.02K(3) for the requirements for electronic submittal of certified payroll records using LCPtracker Pro.

• The flagging and temporary traffic control requirements have been revised. See sections 7-

1.03, 7-1.04, and 12.

• See sections 2-1.11 and 2-1.33B for in-use off-road diesel-fueled vehicle requirements regarding Certificate of Reported Compliance submittals.

• See sections 1-1.06, 1-1.07B, 2-1.23, 2-1.24, 2-1.33B(3), 5-1.13D, and 5-1.13F for “Small

Business Enterprise Participation Goal Requirement” and “Small Business and Non-Small Business Subcontractor Preferences.”

Contract No. 03-1N1304 i

TABLE OF CONTENTS

NOTICE TO BIDDERS

BID ITEM LIST

SPECIAL PROVISIONS

ORGANIZATION

DIVISION I GENERAL PROVISIONS

1 GENERAL

2 BIDDING

5 CONTROL OF WORK

7 LEGAL RELATIONS AND RESPONSIBILITY TO THE PUBLIC

8 PROSECUTION AND PROGRESS

9 PAYMENT

DIVISION II GENERAL CONSTRUCTION

13 WATER POLLUTION CONTROL

DIVISION XII BUILDING CONSTRUCTION

99 BUILDING CONSTRUCTION

ii

STANDARD PLANS LIST

The standard plan sheets applicable to this Contract include those listed below. The applicable revised standard plans (RSPs) listed below are included in the project plans.

A3A Abbreviations (Sheet 1 of 3)

A3B Abbreviations (Sheet 2 of 3)

A3C Abbreviations (Sheet 3 of 3)

A10A Legend - Lines and Symbols (Sheet 1 of 5)

A10B Legend - Lines and Symbols (Sheet 2 of 5)

A10C Legend - Lines and Symbols (Sheet 3 of 5)

A10D Legend - Lines and Symbols (Sheet 4 of 5)

A10E Legend - Lines and Symbols (Sheet 5 of 5)

T1A Temporary Crash Cushion - Sand Filled (Unidirectional)

T1A1 Temporary Crash Cushion - Sand Filled (Unidirectional)

T1B Temporary Crash Cushion - Sand Filled (Bidirectional)

T2 Temporary Crash Cushion - Sand Filled (Shoulder Installations)

T3A Temporary Railing (Type K)

T3B Temporary Railing (Type K)

T3C Temporary Barrier System (Cross Bolt)

T3D Temporary Barrier System (Cross Bolt)

T3E Temporary Barrier System (Cross Bolt)

T3F Temporary Barrier System (Cal F-23)

T3F2 Temporary Barrier System (Cal F-23)

T3G Temporary Barrier System (Staking or Anchoring)

T3G2 Temporary Barrier System (Staking or Anchoring)

RS1 Roadside Signs - Typical Installation Details

RS2 Roadside Signs - Wood Post - Typical Installation Details

RS4 Roadside Signs - Typical Installation - Miscellaneous Details

CANCELED STANDARD PLANS LIST

The standard plan sheets listed below are canceled and not applicable to this contract.

Plan No. Date Canceled Plan No. Date

Canceled Plan No. Date Canceled

No Canceled Standard Plans

NOTICE TO BIDDERS

Bids open Tuesday, December 15, 2026

Dated November 16, 2026

General work description: Boiler system replacement with associated utility work.

The Department will receive electronically sealed bids for the following work: BUILDING

CONSTRUCTION IN EL DORADO COUNTY AT THE KYBURZ MAINTENANCE STATION AT 13561 EL

DORADO FREEWAY.

District-County-Route-Post Mile: 03-ED-5712

Contract No. 03-1N1304

The Contractor must have either a Class A license or the following Class C license which constitutes a majority of the work: C-4.

The DVBE Contract goal is 3 percent.

The SBE Contract goal is 5 percent.

Bids must be on a cost+time basis.

Complete the work within the number of working days bid.

Do not bid less than 90 working days and not more than 125 working days.

The estimated cost of the project is $1,120,000.

The Department will receive bids until 2:00 p.m. on the bid open date via Bid Express website. Bids received after this time will not be accepted. For more information refer to the Electronic Bidding Guide at the Office Engineer's website.

The Department will open and publicly read the bids through webcast/teleconference services immediately after the specified closing time.

For bid results go to:

https://ppmoe.dot.ca.gov/cc

Select Electronic Bidding under the Bidding tab.

District office addresses are provided in the Standard Specifications.

Present bidders' inquiries to the Department and view the Department's responses at:

https://ppmoe.dot.ca.gov/cc?id=cc_bidinquiries

Questions about alleged patent ambiguity of the plans, specifications, or estimate must be asked before bid opening. After bid opening, the Department does not consider these questions as bid protests.

Submit your bid with bidder's security equal to at least 10 percent of the bid.

Under Govt Code § 14835 et seq. and 2 CA Code of Regs § 1896 et seq., the Department gives preference to certified small businesses and non–small businesses who commit to 25 percent certified small business participation.

Under Pub Cont Code § 6107, the Department gives preference to a "California company," as defined, for bid comparison purposes over a nonresident contractor from any state that gives or requires a preference to be given to contractors from that state on its public entity construction contracts.

Prevailing wages are required on this Contract. The Director of the California Department of Industrial Relations determines the general prevailing wage rates. Obtain the wage rates at the DIR website, http://www.dir.ca.gov, or from the Department's Labor Compliance Office of the district in which the work is located.

The Department has made available Notices of Suspension and Proposed Debarment from the Federal Highway Administration. For a copy of the notices, go to https://www.dir.ca.gov/dlse/debar.html.

Additional information is provided in the Excluded Parties List System at https://sam.gov/content/home.

Caltrans and the Construction Industry are committed to making partnering the way we do business. For more information, go to https://dot.ca.gov/programs/construction/partnering.

Department of Transportation

BID ITEM LIST

Item No.

Item Code Item Description Unit of Measure Estimated Quantity

0001 090105 TIME-RELATED OVERHEAD (LS) LS LUMP SUM

0002 130100 JOB SITE MANAGEMENT LS LUMP SUM

0003 130201 WATER POLLUTION CONTROL PROGRAM LS LUMP SUM

0004 130640 TEMPORARY FIBER ROLL LF 1,200

0005 130650 TEMPORARY GRAVEL BAG BERM LF 500

0006 994650 BUILDING WORK LS LUMP SUM

SPECIAL PROVISIONS

ORGANIZATION

Special provisions are under headings that correspond with the main-section headings of the Standard Specifications. A main-section heading is a heading shown in the table of contents of the Standard Specifications.

Each special provision begins with a revision clause that describes or introduces a revision to the Standard Specifications.

Any paragraph added or deleted by a revision clause does not change the paragraph numbering of the Standard Specifications for any other reference to a paragraph of the Standard Specifications.

DIVISION I GENERAL PROVISIONS

1 GENERAL

Add to the table in the 1st paragraph of section 1-1.06:

SBE Small Business Enterprise

Add to section 1-1.07B:

small business enterprise: Small business or small business for the purpose of public works, as certified by the Department of General Services, Office of Small Business and DVBE Services, and as defined in Govt Code § 14835 et seq. and 2 CA Code of Regs § 1896 et seq.

Add to section 1-1.09:

This project is in a freeze-thaw area.

2 BIDDING

Add between the 1st and 2nd paragraphs of section 2-1.06B:

The Department makes the following supplemental project information available:

Supplemental Project Information Means Description

Included in the Information Handout 1. Office of the State Fire Marshal (OSFM) Construction Permit (No. 25-N-5286-C-PI)

2. Form DOT OCR-0003(NEW 04/2024) Final Report - Utilization of Small Business Enterprises

Add to the end of section 2-1.10:

Failing to adequately provide this information may require the bidder to self-perform the work, consistent with Public Contract Code § 4106.

Replace section 2-1.23 with:

2-1.23 SMALL BUSINESS ENTERPRISE PARTICIPATION GOAL REQUIREMENT

2-1.23A General Section 2-1.23 applies if an SBE participation goal requirement is shown on the Notice to Bidders.

The SBE participation goal requirement is in addition to any DVBE goal shown on the Notice to Bidders and the DVBE requirements in section 2-1.22.

Make work available to SBEs and select work parts consistent with the available SBEs, including subcontractors, suppliers, service providers, and truckers.

Meet the SBE participation goal requirement shown on the Notice to Bidders. A bid that demonstrates an SBE participation commitment less than the SBE participation goal requirement is nonresponsive.

Each listed SBE must be certified as a small business or small business for the purpose of public works by 5:00 p.m. on the bid opening date. The complete application and any required substantiating documentation must be received by the Department of General Services by 5:00 p.m. on the bid opening date.

The Department of General Services determines whether an SBE was certified on the bid opening date.

The Department of Transportation confirms an SBE’s certification status.

2-1.23B SBE Submittals Submit SBE information under section 2-1.33.

For the SBE participation goal requirement, submit the following:

1. Completed Small Business Enterprise – Commitment form. Failure to submit the completed form by 4 p.m. on the 4th business day after bid opening may result in a nonresponsive bid.

2. Copy of the quote for each SBE shown on the Small Business Enterprise – Commitment form that describes the type and dollar amount of work shown on the form. Quotes are not required for work that will be completed by SBE prime bidders. Failure to submit a copy of the quote for each SBE listed on the Commitment form by 4 p.m. on the 4th business day after bid opening may result in disallowance of the SBE’s participation.

3. Completed Small Business Enterprise – Confirmation form from each SBE listed on the Commitment form. The form for each SBE is required to establish that the SBE will be participating in the Contract for the type and dollar amount of work shown on the form. Failure to submit completed Confirmation forms for each SBE listed on the Commitment form by 4 p.m. on the 4th business day after bid opening may result in disallowance of the SBE’s participation.

4. If an SBE is participating as a joint venture partner, submit a copy of the joint venture agreement.

The Department may contact you and SBEs to clarify quotes and supporting documentation.

If you elect, at time of bid, to pursue the optional small business or non-small business preference, see section 2-1.24 for the requirements arising from your request for the preference. SBE participation listed to meet the SBE participation goal requirement should not be listed for the preference.

Replace section 2-1.24 with:

2-1.24 SMALL BUSINESS AND NON–SMALL BUSINESS SUBCONTRACTOR PREFERENCES

2-1.24A General Section 2-1.24 applies to a non-federal-aid contract.

The Department applies small business preferences and non–small business preferences under Govt Code § 14835 et seq. and 2 CA Code of Regs § 1896 et seq.

Any contractor, subcontractor, supplier, or service provider who qualifies as a small business or small business for the purpose of public works is encouraged to apply for certification as an SBE by submitting its application to the Department of General Services, Office of Small Business and DVBE Services.

The Department of General Services determines whether an SBE was certified on the bid opening date.

The Department of Transportation confirms an SBE’s certification status before applying the small business or non-small business preference.

Contract award is based on the total bid, not the reduced bid.

Pursuant to Govt Code § 14838, SBE participation listed on the Small Business Enterprise – Commitment form used to meet the SBE participation goal requirement should not be listed on the Certified Small Business Listing for the Non-Small Business Preference form. Listing the same SBE participation on both the Small Business Enterprise – Commitment form and on the Certified Small Business Listing for the Non-Small Business Preference form may result in disallowance of the SBE’s participation toward the small business or non-small business preference.

2-1.24B Small Business Preference The Department allows a bidder certified as an SBE by the Department of General Services, Office of Small Business and DVBE Services, a preference if:

1. Bidder submitted a completed Request for Small Business Preference or Non–Small Business Preference form with its bid

2. Low bidder did not request the preference or is not certified as a small business

The Bidder's signature on the Request for Small Business Preference or Non–Small Business Preference form certifies that the Bidder is certified as an SBE at the date and time of bid or has submitted a complete application to the Department of General Services. The complete application and any required substantiating documentation must be received by the Department of General Services by 5:00 p.m. on the bid opening date.

The small business preference is a reduction for bid comparison in the total bid submitted by the small business contractor by the lesser of the following amounts:

1. 5 percent of the verified total bid of the low bidder

2. $50,000

If the Department determines that a certified small business bidder is the low bidder after the application of the small business preference, the Department does not consider a request for non–small business preference.

2-1.24C Non–Small Business Subcontractor Preference At time of bid, the Department allows a bidder not certified as an SBE by the Department of General Services, Office of Small Business and DVBE Services, the option of requesting the non-small business subcontractor preference. If a bidder elects to pursue that option at the time of bid, the bidder is required to meet the corresponding commitment.

For the non-small business subcontractor preference, submit the following:

1. Completed Request for Small Business Preference or Non–Small Business Preference form with your bid

2. Completed Certified Small Business Listing for the Non–Small Business Preference form which shows you are subcontracting at least 25 percent to certified SBEs

Each listed SBE must be certified as a small business or small business for the purpose of public works by 5:00 p.m. on the bid opening date. The complete application and any required substantiating documentation must be received by the Department of General Services by 5:00 p.m. on the bid opening date.

Failure to submit a completed Certified Small Business Listing for the Non–Small Business Preference form by 4 p.m. on the 4th business day after bid opening will result in a nonresponsive bid.

The non–small business subcontractor preference is a reduction for bid comparison in the total bid submitted by the non–small business contractor requesting the preference by the lesser of the following amounts:

1. 5 percent of the verified total bid of the low bidder

2. $50,000

Replace the table in the 1st paragraph of section 2-1.33B(3)(b)(ii) with:

Bid Form Submittal Schedule for a Non-Federal-Aid Contract with a DVBE Goal

Form Submittal deadline

Bid to the Department of Transportation Time of bid except for the public works contractor registration number for a joint-venture contract

For a joint-venture contract, copy of the Bid to the Department of Transportation as submitted at the time of bid with the public works contractor registration number

10 days after bid opening

Subcontractor List Time of bid In-Use Off-Road Diesel-Fueled Vehicle List 10 days after bid opening Small Business/DVBE/DBE Certification Status Time of bid Opt Out of Payment Adjustments for Price Index Fluctuationsa Time of bid

Certified DVBE Summary No later than 4 p.m. on the 4th business day after bid opening

California Company Preference Time of bid

Small Business Enterprise – Commitment No later than 4 p.m. on the 4th business day after bid opening

Small Business Enterprise – Confirmation No later than 4 p.m. on the 4th business day after bid opening

Request for Small Business Preference or Non– Small Business Preferencea Time of bid

Certified Small Business Listing for the Non– Small Business Preferencea

No later than 4 p.m. on the 4th business day after bid opening aSubmit only if you choose the option or preference.

Replace the table in the 1st paragraph of section 2-1.33B(3)(c)(ii) with:

Bid Form Submittal Schedule for a Non-Federal-Aid Contract without a DVBE Goal

Form Submittal deadline

Bid to the Department of Transportation Time of bid except for the public works contractor registration number for a joint-venture contract

For a joint-venture contract, copy of the Bid to the Department of Transportation as submitted at the time of bid with the public works contractor registration number

10 days after bid opening

Subcontractor List Time of bid In-Use Off-Road Diesel-Fueled Vehicle List 10 days after bid opening Small Business/DVBE/DBE Certification Status Time of bid Opt Out of Payment Adjustments for Price Index Fluctuationsa Time of bid

California Company Preference Time of bid

Certified DVBE Summaryb No later than 4 p.m. on the 4th business day after bid opening

Small Business Enterprise – Commitment No later than 4 p.m. on the 4th business day after bid opening

Small Business Enterprise – Confirmation No later than 4 p.m. on the 4th business day after bid opening

Request for Small Business Preference or Non– Small Business Preferencea Time of bid

Certified Small Business Listing for the Non– Small Business Preferencea

No later than 4 p.m. on the 4th business day after bid opening aSubmit only if you choose the option or preference.

bSubmit only if you obtain DVBE participation or you are the apparent low bidder, 2nd low bidder, or 3rd low bidder and you choose to receive the specified incentive.

Replace the table in the 1st paragraph of section 2-1.33B(3)(b)(ii) with:

Bid Form Submittal Schedule for a Non-Federal-Aid Contract with a DVBE Goal

Form Submittal deadline

Bid to the Department of Transportation Time of bid except for the public works contractor registration number for a joint-venture contract

For a joint-venture contract, copy of the Bid to the Department of Transportation as submitted at the time of bid with the public works contractor registration number

10 days after bid opening

Subcontractor List Time of bid In-Use Off-Road Diesel-Fueled Vehicle List 10 days after bid opening Small Business/DVBE/DBE Certification Status Time of bid Opt Out of Payment Adjustments for Price Index Fluctuationsa Time of bid

Certified DVBE Summary No later than 4 p.m. on the 4th business day after bid opening

California Company Preference Time of bid Request for Small Business Preference or Non– Small Business Preferencea Time of bid

Certified Small Business Listing for the Non– Small Business Preferencea

No later than 4 p.m. on the 4th business day after bid opening aSubmit only if you choose the option or preference.

Replace the table in the 1st paragraph of section 2-1.33B(3)(c)(ii) with:

Bid Form Submittal Schedule for a Non-Federal-Aid Contract without a DVBE Goal

Form Submittal deadline

Bid to the Department of Transportation Time of bid except for the public works contractor registration number for a joint-venture contract

For a joint-venture contract, copy of the Bid to the Department of Transportation as submitted at the time of bid with the public works contractor registration number

10 days after bid opening

Subcontractor List Time of bid In-Use Off-Road Diesel-Fueled Vehicle List 10 days after bid opening Small Business/DVBE/DBE Certification Status Time of bid Opt Out of Payment Adjustments for Price Index Fluctuationsa Time of bid

California Company Preference Time of bid

Certified DVBE Summaryb No later than 4 p.m. on the 4th business day after bid opening

Request for Small Business Preference or Non– Small Business Preferencea Time of bid

Certified Small Business Listing for the Non– Small Business Preferencea

No later than 4 p.m. on the 4th business day after bid opening aSubmit only if you choose the option or preference.

bSubmit only if you obtain DVBE participation or you are the apparent low bidder, 2nd low bidder, or 3rd low bidder and you choose to receive the specified incentive.

5 CONTROL OF WORK

Replace section 5-1.13D with:

5-1.13D Non-Small Business Preference 5-1.13D(1) General Section 5-1.13D applies to a non-federal-aid contract when you have obtained a non-small business subcontractor preference under section 2-1.24.

Use each SBE as shown on the Certified Small Business Listing for the Non-Small Business Preference form unless you receive authorization for a substitution under section 5-1.13D(3).

Maintain records of subcontracts and agreements made with each SBE. Include in the records:

1. SBE subcontract or agreement

2. Name and business address of each business

3. Proof of each payment made to an SBE

Upon reasonable notice and during normal business hours, permit access to the SBE premises for the purpose of:

1. Interviewing employees.

2. Inspecting and copying books, records, accounts, and other material that may be relevant to a matter under investigation.

Upon work completion, complete a Final Report – Utilization of Small Business Enterprise form and submit within 10 days of Contract acceptance. The Department withholds the greater of 10 percent of the SBE work amount or $10,000 until the form is submitted. The Department releases the withhold upon submission of the completed form. If additional payments are made to an SBE after submittal of the completed form, submit an updated form to reflect such payments.

5-1.13D(2) Commercially Useful Function SBEs must perform a commercially useful function under 2 CA Code Regs § 1896.15 when performing tasks listed on the Certified Small Business Listing for the Non-Small Business Preference form and as a Department authorized substitute SBE. The SBE’s value of work will only count toward the non-small business preference if the SBE performs a commercially useful function under 2 CA Code Regs § 1896.15.

Provide written notification to the Engineer at least 15 days in advance of each SBE’s initial performance of work on the Contract. Include the SBE’s name, contract work to be performed, and the location, date, and time of where the SBE’s work will take place.

Monitor each SBE’s performance of a commercially useful function throughout their duration of work on the Contract. Maintain supporting documentation of commercially useful function related records. Provide copies of the following to the Department within 5 business days of a specific SBE request:

1. Subcontract or agreement with the SBE

2. Purchase orders

3. Bills of lading

4. Invoices

5. Proof of payment

You and your SBEs must submit any commercially useful function related records and documents within 5 business days of Department request such as:

1. Proof of ownership or lease and rental agreements for equipment

2. Tax records

3. Employee rosters

4. Certified payroll records

5. Inventory rosters

Notify the Engineer immediately if you believe an SBE may not be performing a commercially useful function.

Failure to submit requested records and documents, or failure of an SBE to perform a commercially useful function, will be a violation of these specifications. Such violations will result in referral to the Department of General Services, and you may be subject to sanctions under Govt Code § 14842 et seq.

5-1.13D(3) Substitutions Substitution of an SBE may be requested for the reasons listed in Pub Cont Code § 4107. The Department will consider your SBE substitution request under 2 CA Code Regs § 1896.10. The substitute must be another SBE.

The requirement that an SBE be certified by the bid opening date does not apply to SBE substitutions after contract award.

Include in your substitution request:

1. Copy of the written notice issued to the SBE with proof of delivery

2. Copy of the SBE response to the notice

3. Your explanation of the reason for the substitution request

4. Names and certification numbers of the listed SBE and the proposed substitute SBE

5. Description of the work to be performed including dollar amount or percentage of overall contract the proposed substitute SBE will perform

6. If an SBE substitution cannot occur, written justification and the steps that were taken to try to acquire a new SBE and how that non-small business preference portion of the Contract will be fulfilled

Upon receipt of the substitution request, the listed SBE will be notified by the Department of the substitution request. The listed SBE will have 5 business days to respond. Where the listed SBE objects to the substitution, the Department will schedule a hearing.

If the Department authorizes your SBE substitution request, it will do so in writing.

Work performed by a firm other than the listed SBE or authorized substitute will be a violation of these specifications. Such violations will result in notification of the Department of General Services, and you may be subject to sanctions under Govt Code § 14842 et seq.

Replace section 5-1.13F with:

5-1.13F Small Business Enterprise Participation Goal Requirement 5-1.13F(1) General Section 5-1.13F applies to a non-federal-aid contract if an SBE participation goal requirement is shown on the Notice to Bidders.

Use each SBE as shown on the Small Business Enterprise – Commitment form unless you receive authorization for a substitution under section 5-1.13F(3).

Maintain records of subcontracts and agreements made with each SBE. Include in the records:

1. SBE subcontract or agreement

2. Name and business address of each business

3. Proof of each payment made to an SBE

Upon reasonable notice and during normal business hours, permit access to the SBE premises for the purpose of:

1. Interviewing employees.

2. Inspecting and copying books, records, accounts, and other material that may be relevant to a matter under investigation.

Upon work completion, complete a Final Report – Utilization of Small Business Enterprise form and submit within 10 days of Contract acceptance. The Department withholds the greater of 10 percent of the SBE work amount or $10,000 until the form is submitted. The Department releases the withhold upon submission of the completed form. If additional payments are made to an SBE after submittal of the completed form, submit an updated form to reflect such payments.

5-1.13F(2) Commercially Useful Function SBEs must perform a commercially useful function under 2 CA Code Regs § 1896.15 when performing tasks listed on the Small Business Enterprise – Commitment form and as a Department authorized substitute SBE. The SBE’s value of work will only count toward the SBE participation goal requirement if the SBE performs a commercially useful function under 2 CA Code Regs § 1896.15.

Provide written notification to the Engineer at least 15 days in advance of each SBE’s initial performance of work on the Contract. Include the SBE’s name, contract work to be performed, and the location, date, and time of where the SBE’s work will take place.

Monitor each SBE’s performance of a commercially useful function throughout their duration of work on the Contract. Maintain supporting documentation of commercially useful function related records. Provide copies of the following to the Department within 5 business days of a specific SBE request:

1. Subcontract or agreement with the SBE

2. Purchase orders

3. Bills of lading

4. Invoices

5. Proof of payment

You and your SBEs must submit any commercially useful function related records and documents within 5 business days of Department request such as:

1. Proof of ownership or lease and rental agreements for equipment

2. Tax records

3. Employee rosters

4. Certified payroll records

5. Inventory rosters

Notify the Engineer immediately if you believe an SBE may not be performing a commercially useful function.

Failure to submit requested records and documents, or failure of an SBE to perform a commercially useful function, will be a violation of these specifications. Such violations will result in referral to the Department of General Services, and you may be subject to sanctions under Govt Code § 14842 et seq.

5-1.13F(3) Substitutions Substitution of an SBE may be requested for the reasons listed in Pub Cont Code § 4107. The Department will consider your SBE substitution request under 2 CA Code Regs § 1896.10. The substitute must be another SBE.

The requirement that an SBE be certified by the bid opening date does not apply to SBE substitutions after contract award.

Include in your substitution request:

1. Copy of the written notice issued to the SBE with proof of delivery

2. Copy of the SBE response to the notice

3. Your explanation of the reason for the substitution request

4. Names and certification numbers of the listed SBE and the proposed substitute SBE

5. Description of the work to be performed including dollar amount or percentage of overall contract the proposed substitute SBE will perform

6. If an SBE substitution cannot occur, written justification and the steps that were taken to try to acquire a new SBE and how that SBE participation goal requirement portion of the Contract will be fulfilled

Upon receipt of the substitution request, the listed SBE will be notified by the Department of the substitution request. The listed SBE will have 5 business days to respond. Where the listed SBE objects to the substitution, the Department will schedule a hearing.

If the Department authorizes your SBE substitution request, it will do so in writing.

Work performed by a firm other than the listed SBE or authorized substitute will be a violation of these specifications. Such violations will result in notification of the Department of General Services, and you may be subject to sanctions under Govt Code § 14842 et seq.

7 LEGAL RELATIONS AND RESPONSIBILITY TO THE PUBLIC

Add to the end of section 7-1.02M(2):

Obtain the emergency phone numbers of El Dorado County Fire District - Station 16 . Submit these phone numbers to the Engineer before the start of job site activities. Post the agencies names and emergency phone numbers at a prominent place at the job site.

Hydrocarbon-fueled engines, both stationary and mobile, must be equipped with spark arresters pursuant to Pub Res Code § 4442 except for either of the following:

1. Motor trucks, truck tractors, buses, or passenger vehicles, if equipped with a muffler as defined in the Vehicle Code

2. Equipment powered by turbocharged engines if:

2.1 Exhausted gases pass through the rotating turbine wheel

2.2 There is no exhaust bypass to the atmosphere

2.3 The turbocharger is in effective mechanical condition

Each toilet must have a metal ashtray at least 6 inches in diameter by 8 inches deep, half-filled with sand, and within easy reach of anyone accessing the facility.

Locate flammable materials at least 50 feet away from equipment service, parking, and gas or oil storage areas. Each small mobile or stationary engine site must be cleared of flammable material for a radius of at least 15 feet from the engine.

Furnish the following fire tools:

1. 1 shovel and 1 fully charged fire extinguisher UL rated at 4B:C or more on each truck, personnel vehicle, tractor, grader, or other heavy equipment.

2. 1 shovel and one 5-gallon water-filled backpack fire pump for each welder.

3. 1 shovel or 1 chemical pressurized fire extinguisher, fully charged, for each gasoline-powered tool, including chain saws, soil augers, and rock drills. The fire tools must always be within 25 feet from the point of operation of the power tool. Each fire extinguisher must be of the type and size required by the California Department of Forestry and Fire Protection.

Each shovel must be size O or larger and at least 46 inches long.

Furnish a pickup truck and operator for the sole purpose of fire control during working hours. The truck must be equipped with:

1. 10 shovels, 5 axes, two 5-gallon water-filled backpack fire pumps

2. 100-gallon tank of water with a gasoline motor powered pump and 100 feet of 3/4-inch hose on a reel

In addition to being available at the site of the work, the truck and operator must patrol the area of construction from noon or the start of job site activities, whichever is later, until at least 1/2 hour after job site activities have ended. If the fire danger rating is "very high" or "extreme" or "fire weather watches" or "red flag warning" is issued, the truck and operator must patrol the area of construction while work is being done and for at least 1/2 hour after job site activities have ended.

Cal Fire, USFS, and BLM have established the following adjective class ratings for 5 levels of fire danger for use in public information releases and fire protection signing: "low," "moderate," "high," "very high," "extreme." Obtain the fire danger rating daily for the project area from the nearest Cal Fire unit headquarters, USFS ranger district office, or BLM field office. Monitor the National Weather Service daily forecasts for "fire weather watches" and "red flag warnings" covering the project’s locations.

If the fire danger rating is "very high" or a "fire weather watch" is issued, then:

1. Falling of dead trees or snags must be discontinued.

2. No open burning is permitted and fires must be extinguished.

3. Welding must be discontinued except in an enclosed building or within an area cleared of flammable material for a radius of 25 feet.

4. Blasting must be discontinued.

5. Smoking is allowed only in automobiles and cabs of trucks equipped with an ashtray or in cleared areas immediately surrounded by a fire break unless prohibited by other authority.

6. Vehicular travel is restricted to cleared areas except in case of emergency.

If the fire danger rating is "extreme" or a "red flag warning" is issued, take the precautions specified for a "very high" fire danger rating or a "fire weather watch" issuance, except:

1. Smoking is only allowed in automobiles and cabs of trucks equipped with an ashtray.

2. Work of a nature that could start a fire requires that properly equipped fire guards be assigned to such operation for the duration of the work.

The Engineer may suspend work wholly or in part due to hazardous fire conditions. If the controlling activity is suspended due to hazardous fire conditions, the associated days are considered adverse weather-related conditions and working days will not be assessed. If field and weather conditions become such that the work is suspended, section 7-1.02M(2) will not be enforced for the period of the suspension.

8 PROSECUTION AND PROGRESS

Replace the row for Schedule in the table in the 2nd paragraph of section 8-1.03 with:

Schedule Baseline schedule and weekly statement of working days report

Replace section 8-1.04C with:

8-1.04C Delayed Start Section 8-1.04B does not apply.

Start job site activities within 185 days after receiving notice that the Contract has been approved by the Attorney General or the attorney appointed and authorized to represent the Department.

Do not start job site activities until the Department authorizes or accepts your submittal for:

1. Biological resource information program

2. WPCP or SWPPP, whichever applies

You may enter the job site only to measure controlling field dimensions and locate utilities.

Do not start other job site activities until all submittals from the above list are authorized or accepted and the following information is received by the Engineer:

1. Notice of Materials To Be Used form.

2. Written statement from the vendor that the order for sign panels has been received and accepted by the vendor. The statement must show the dates that the materials will be shipped.

3. Written statement from the vendor that the order for electrical material has been received and accepted by the vendor. The statement must show the dates that the materials will be shipped.

You may start job site activities before the 185th day after Contract approval if you:

1. Obtain specified authorization or acceptance for each submittal before the 55th day

2. Receive authorization to start

Submit a notice 72 hours before starting job site activities. If the project has more than 1 location of work, submit a separate notice for each location.

9 PAYMENT

Replace the 1st paragraph of section 9-1.11D with:

For progress payments, the total work completed for the TRO bid item is the number of working days shown for the pay period on the weekly statement of working days report.

DIVISION II GENERAL CONSTRUCTION

13 WATER POLLUTION CONTROL

Add between the 4th and 5th paragraphs of section 13-2.01C:

The Central Valley - Region 5 RWQCBs will review the authorized WPCP

DIVISION XII BUILDING CONSTRUCTION

99 BUILDING CONSTRUCTION

Replace "Reserved" in section 99 with:

99-1 GENERAL REQUIREMENTS

99-010000 GENERAL REQUIREMENTS

PART 1 - GENERAL

1.1 SUMMARY

A. Section 99-1 includes general specifications for performing building construction work.

B. The building construction work includes the removal of the existing boiler and controller, and the installation of a new boiler and controller, along with associated mechanical and electrical equipment in the mechanical room located within the existing equipment storage building, as shown on the sheets labeled GP, GI, A, M, and EE.

C. Sections 15 through 98 do not apply to building construction work except where a specific reference is made to one of these sections.

D. The styles of section 99 differ from the styles of the other sections in that:

1. The 5-digit number that follows "99-" and the title of each correlate with the 16-division CSI MasterFormat number and title except as specified below.

2. Within section 99, the Department is gradually changing the specifications to align with CSI's MasterFormat styles and 50-division CSI MasterFormat numbers. Because of this transition, the format, organization, and language may vary between sections. Until the transition is complete, a 50-division section number, that follows "99-" will be located in the division that correlates with the 16-division CSI MasterFormat.

3. Some section 99 specifications are in a streamlined form. In these specifications, interpret a colon as "must be."

E. Section 99 specifications are located in the divisions as shown in the following table of contents:

Section 99 Specifications Table of Contents

99-1 GENERAL REQUIREMENTS

99-010000 - GENERAL REQUIREMENTS

99-2 SITEWORK

99-02071 - REMOVING PORTIONS OF EXISTING FACILITIES

99-3 CONCRETE AND REINFORCEMENT (Not Used)

99-4 MASONRY (Not Used)

99-5 METALS (Not Used)

99-6 WOOD AND PLASTICS (Not Used)

99-7 THERMAL AND MOISTURE PROTECTION (Not Used)

99-8 DOORS AND WINDOWS (Not Used)

99-9 FINISHES (Not Used)

99-10 SPECIALTIES

99-10522 - FIRE EXTINGUISHERS

99-11 EQUIPMENT (Not Used)

99-12 FURNISHINGS (Not Used)

99-13 SPECIAL CONSTRUCTION (Not Used)

99-14 CONVEYING SYSTEMS (Not Used)

99-15 MECHANICAL

99-15050 - MECHANICAL WORK

99-15060 - PIPE, FITTINGS, AND VALVES

99-15250 - MECHANICAL INSULATION

99-15441 - PLUMBING FIXTURES

99-15510 - HYDRONIC HEATING SYSTEM

99-15555 - BOILER

99-16 ELECTRICAL

99-16010 - ELECTRICAL WORK

99-16050 - BASIC MATERIALS AND METHODS

99-16432 - ELECTRICAL EQUIPMENT

1.2 ABBREVIATIONS

A. Industry Organizations: Where abbreviations and acronyms are used in Specifications, they must mean the recognized name of the entities in the following list. The information in this list is subject to change.

AABC - Associated Air Balance Council; www.aabc.com.

AAMA - American Architectural Manufacturers Association; www.aamanet.org.

AAPFCO - Association of American Plant Food Control Officials; www.aapfco.org.

AASHTO - American Association of State Highway and Transportation Officials;

www.transportation.org.

AATCC - American Association of Textile Chemists and Colorists; www.aatcc.org.

ABMA - American Bearing Manufacturers Association; www.americanbearings.org.

ABMA - American Boiler Manufacturers Association; www.abma.com.

ACI - American Concrete Institute; (Formerly: ACI International); www.concrete.org.

ACPA - American Concrete Pipe Association; www.concrete-pipe.org.

ADAAG - ADA Accessibility Guidelines for Buildings and Facilities AEIC - Association of Edison Illuminating Companies, Inc. (The); www.aeic.org.

AF&PA - American Forest & Paper Association; www.afandpa.org.

AGA - American Gas Association; www.aga.org.

AHAM - Association of Home Appliance Manufacturers; www.aham.org.

AHRI - Air-Conditioning, Heating, and Refrigeration Institute (The); www.ahrinet.org.

AI - Asphalt Institute; www.asphaltinstitute.org.

AIA - American Institute of Architects (The); www.aia.org.

AISC - American Institute of Steel Construction; www.aisc.org.

AISI - American Iron and Steel Institute; www.steel.org.

AITC - American Institute of Timber Construction; www.aitc-glulam.org.

ALSC - American Lumber Standard Committee AMCA - Air Movement and Control Association International, Inc.; www.amca.org.

ANSI - American National Standards Institute; www.ansi.org.

AOSA - Association of Official Seed Analysts, Inc.; www.aosaseed.com.

APA - APA - The Engineered Wood Association; www.apawood.org.

APA - Architectural Precast Association; www.archprecast.org.

API - American Petroleum Institute; www.api.org.

ARI - Air-Conditioning & Refrigeration Institute; (See AHRI).

ARI - American Refrigeration Institute; (See AHRI).

ARMA - Asphalt Roofing Manufacturers Association; www.asphaltroofing.org.

ASCE - American Society of Civil Engineers; www.asce.org.

ASCE/SEI - American Society of Civil Engineers/Structural Engineering Institute; (See ASCE).

ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers;

www.ashrae.org.

ASME - ASME International; (American Society of Mechanical Engineers); www.asme.org.

ASSE - American Society of Sanitary Engineering; www.asse-plumbing.org.

ASSP - American Society of Safety Professionals (The); www.assp.org.

ASTM - ASTM International; www.astm.org.

ATIS - Alliance for Telecommunications Industry Solutions; www.atis.org.

AVIXA - Audiovisual and Integrated Experience Association; (Formerly: Infocomm International);

www.soundandcommunications.com.

AWEA - American Wind Energy Association; www.awea.org.

AWI - Architectural Woodwork Institute; www.awinet.org.

AWMAC - Architectural Woodwork Manufacturers Association of Canada; www.awmac.com.

AWPA - American Wood Protection Association; www.awpa.com.

AWS - American Welding Society; www.aws.org.

AWWA - American Water Works Association; www.awwa.org.

BHMA - Builders Hardware Manufacturers Association; www.buildershardware.com.

BIA - Brick Industry Association (The); www.gobrick.com.

BICSI - BICSI, Inc.; www.bicsi.org.

BIFMA - BIFMA International; (Business and Institutional Furniture Manufacturer's Association);

www.bifma.org.

BISSC - Baking Industry Sanitation Standards Committee; www.bissc.org.

BWF - Badminton World Federation; (Formerly: International Badminton Federation);

www.bissc.org.

CBC - California Building Code CCR - California Code of Regulations CFC - California Fire Code CDA - Copper Development Association; www.copper.org.

CE - Conformite Europeenne; www.ec.europa.eu/growth/single-market/ce-marking/.

CEA - Canadian Electricity Association; www.electricity.ca.

CEC - California Electrical Code CFFA - Chemical Fabrics and Film Association, Inc.; www.chemicalfabricsandfilm.com.

CFSEI - Cold-Formed Steel Engineers Institute; www.cfsei.org.

CGA - Compressed Gas Association; www.cganet.com.

CIMA - Cellulose Insulation Manufacturers Association; www.cellulose.org.

CISCA - Ceilings & Interior Systems Construction Association; www.cisca.org.

CISPI - Cast Iron Soil Pipe Institute; www.cispi.org.

CLFMI - Chain Link Fence Manufacturers Institute; www.chainlinkinfo.org.

CMC - California Mechanical Code CPA - Composite Panel Association; www.compositepanel.org.

CPC - California Plumbing Code CRI - Carpet and Rug Institute (The); www.carpet-rug.org.

CRRC - Cool Roof Rating Council; www.coolroofs.org.

CRSI - Concrete Reinforcing Steel Institute; www.crsi.org.

CSA - CSA Group; www.csa-group.org.

CSI - Construction Specifications Institute (The); www.csiresources.org.

CSSB - Cedar Shake & Shingle Bureau; www.cedarbureau.org.

CTA - Consumer Technology Association; www.cta.tech.

CTI - Cooling Technology Institute; (Formerly: Cooling Tower Institute);

www.coolingtechnology.org.

CWC - Composite Wood Council; (See CPA).

DASMA - Door and Access Systems Manufacturers Association; www.dasma.com.

DHA - Decorative Hardwoods Association; (Formerly: Hardwood Plywood & Veneer Association);

www.decorativehardwoods.org.

DHI - Door and Hardware Institute; www.dhi.org.

ECA - Electronic Components Association; (See ECIA).

ECAMA - Electronic Components Assemblies & Materials Association; (See ECIA).

ECIA - Electronic Components Industry Association; www.ecianow.org.

EIA - Electronic Industries Alliance; (See TIA).

EIMA - EIFS Industry Members Association; www.eima.com.

EJMA - Expansion Joint Manufacturers Association, Inc.; www.ejma.org.

EOS/ESD Association; (Electrostatic Discharge Association); www.esda.org.

ESTA - Entertainment Services and Technology Association; (See PLASA).

ESO - Electrical Safety Orders ETL - Intertek (See Intertek); www.intertek.com.

EVO - Efficiency Valuation Organization; www.evo-world.org.

FCI - Fluid Controls Institute; www.fluidcontrolsinstitute.org.

FIBA - Federation Internationale de Basketball; (The International Basketball Federation);

www.fiba.com.

FIVB - Federation Internationale de Volleyball; (The International Volleyball Federation);

www.fivb.org.

FM Approvals - FM Approvals LLC; www.fmglobal.com.

FM Global - FM Global; (Formerly: FMG - FM Global); www.fmglobal.com.

FRSA - Florida Roofing, Sheet Metal Contractors Association, Inc.; www.floridaroof.com.

FS - Federal Specification FSA - Fluid Sealing Association; www.fluidsealing.com.

FSC - Forest Stewardship Council U.S.; www.fscus.org.

GA - Gypsum Association; www.gypsum.org.

GANA - Glass Association of North America; (See NGA).

GS - Green Seal; www.greenseal.org.

HI - Hydraulic Institute; www.pumps.org.

HI/GAMA - Hydronics Institute/Gas Appliance Manufacturers Association; (See AHRI).

HMMA - Hollow Metal Manufacturers Association; (See NAAMM).

HPVA - Hardwood Plywood & Veneer Association; (See DHA).

HPW - H. P. White Laboratory, Inc.; www.hpwhite.com.

IAPSC - International Association of Professional Security Consultants; www.iapsc.org.

IAS - International Accreditation Service; www.iasonline.org.

IBC - International Building Code ICBO - International Conference of Building Officials; (See ICC).

ICC - International Code Council; www.iccsafe.org.

ICEA - Insulated Cable Engineers Association, Inc.; www.icea.net.

ICPA - International Cast Polymer Association; www.theicpa.com.

ICRI - International Concrete Repair Institute, Inc.; www.icri.org.

IEC - International Electrotechnical Commission; www.iec.ch.

IEEE - Institute of Electrical and Electronics Engineers, Inc. (The); www.ieee.org.

IES - Illuminating Engineering Society; (Formerly: Illuminating Engineering Society of North America); www.ies.org.

IESNA - Illuminating Engineering Society of North America; (See IES).

IEST - Institute of Environmental Sciences and Technology; www.iest.org.

IGMA - Insulating Glass Manufacturers Alliance; www.igmaonline.org.

IGSHPA - International Ground Source Heat Pump Association; www.igshpa.org.

II - Infocomm International; (See AVIXA).

ILI - Indiana Limestone Institute of America, Inc.; www.iliai.com.

Intertek - Intertek Group; (Formerly: ETL SEMCO; Intertek Testing Service NA);

www.intertek.com.

ISA - International Society of Automation (The); (Formerly: Instrumentation, Systems, and

Automation Society); www.isa.org.

ISAS - Instrumentation, Systems, and Automation Society (The); (See ISA).

ISFA - International Surface Fabricators Association; (Formerly: International Solid Surface

Fabricators Association); www.isfanow.org.

ISO - International Organization for Standardization; www.iso.org.

ISSFA - International Solid Surface Fabricators Association; (See ISFA).

ITU - International Telecommunication Union; www.itu.int.

KCMA - Kitchen Cabinet Manufacturers Association; www.kcma.org.

LMA - Laminating Materials Association; (See CPA).

LPI - Lightning Protection Institute; www.lightning.org.

MBMA - Metal Building Manufacturers Association; www.mbma.com.

MCA - Metal Construction Association; www.metalconstruction.org.

MFMA - Maple Flooring Manufacturers Association, Inc.; www.maplefloor.org.

MFMA - Metal Framing Manufacturers Association, Inc.; www.metalframingmfg.org.

MHIA - Material Handling Industry of America; www.mhia.org.

MIA - Marble Institute of America; (See NSI).

MMPA - Moulding & Millwork Producers Association; www.wmmpa.com.

MPI - Master Painters Institute; www.paintinfo.com.

MSS - Manufacturers Standardization Society of The Valve and Fittings Industry Inc.; www.mss-hq.org.

NAAMM - National Association of Architectural Metal Manufacturers; www.naamm.org.

NACE - NACE International; (National Association of Corrosion Engineers International);

www.nace.org.

NADCA - National Air Duct Cleaners Association; www.nadca.com.

NAIMA - North American Insulation Manufacturers Association; www.naima.org.

NALP - National Association of Landscape Professionals; www.landscapeprofessionals.org.

NBGQA - National Building Granite Quarries Association, Inc.; www.nbgqa.com.

NBI - New Buildings Institute; www.newbuildings.org.

NCAA - National Collegiate Athletic Association (The); www.ncaa.org.

NCMA - National Concrete Masonry Association; www.ncma.org.

NEBB - National Environmental Balancing Bureau; www.nebb.org.

NECA - National Electrical Contractors…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .