This document is a Site Layout Plan (Sheet CS-102) for a New Administration Building project located at 2002 Holcombe Boulevard, Houston, TX 77030, prepared by H2B, Inc. The plan illustrates the civil and infrastructure design for a 75' x 120' new administrative building with an associated parking facility and utility improvements within the project scope limits.

The site layout specifies construction requirements including new parking with 20 stalls at 9-foot spacing (180 linear feet), 16 stalls at 9-foot spacing (144 linear feet), and additional stalls at varying configurations totaling approximately 135-180 linear feet. Infrastructure improvements include new water lines, sanitary sewer lines, storm sewer systems with junction boxes, electrical lines with pull boxes and vault installations, communication/fiber optic cable conduits, and ADA-compliant access features. Pavement specifications require new 5-inch and 6-inch concrete pavement, new asphalt with 3-foot and 5-foot radii curves, and 5-foot concrete sidewalks. The plan identifies new features such as double and single overhead lighting, fire hydrant assemblies, gate valves, cleanouts, and bollards. Utility connections reference coordination with MEP drawings and notes that some necessary utility connections will occur outside the project scope limit line per VA Project Number 580-16-102. The horizontal and vertical control points are established using NAD83 (2011 ADJ.) coordinate system with NAVD 1988 elevation datum referenced to benchmark D100 BM14 at Braeswood Boulevard and Brays Bayou.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RIM: 43.01'

ELEC MH

RIM: 42.85'

ELEC MH

6" PVC W: 40.13'

18" PVC S: 33.80'

12" PVC E: 33.83'

10" PVC NE: 34.53'

RIM: 43.83'

SAN MH

T E

E

TTRANSFORMER

ELEC PANEL

GATE

A S

P H

A L

T

ELEC PB

E L E C

P B

SHACK

GUARD

ELEC VAULT

ELEC PB

T R

N S

F M

R x

T R

N S

F M

R x

T R

N S

F M

R x

T R

N S

F M

R x

T

TRNSFMR

1.5'x2'

TELE PED

INVERT: 35.56'

CAPPED OFF

RIM: 42.96'

ABANDONED

SAN MH

(TONE MARKS)

FIBER OPTIC CABLE

W/ LIGHT

4" BOLLARD

ICV

P

LA

N

TE

R

WV EB

LP

SA

SA

S T

A L

L

A L

A L

A L

A L

R

R

TYP

19'

5' SIDEWALK

I

D E

W A

L K

5' SIDEWALK

52'

19'

10'

115'24.3'

34' 34'

100.5'

120'

D R I

V I

N G

A

S L

E

I

V I

S L

E

I

V I

S L

E

D E

W A

L K

TYP

19'

TYP

19'

TYP

19'

TYP

19'

TYP

19'

R

3'R

R

3'R

11' 8'5' 5'5'

T Y

P

T Y

P

T Y

P

T Y

P

T Y

P

18'

24'

24'

FF=45.00

ADMIN BLDG

NEW 75'x120'

NEW ELEC LINE

NEW FH

NEW ADMIN BLDG PROJECT LIMIT LINE

NEW ADMIN BLDG PROJECT LIMIT LINE

N E

W A

D M

IN

B

L D

G P

R O J E

C T L

IM

IT

L

IN

E

N E

W A

D M

IN

B

L D

G P

R O J E

C T L

IM

IT

L

IN

E

NEW WL

R 5

R

188'R

SIGN (TYP)

NEW ADA

R

C U

R B

C U

R B

CURB

0.5'

(TYP)

STOPS

NEW PKG

LINE

NEW COMM

N

O T

C O

N T

R A

C

E

F U

T U

R E

E X I

S T I

C E

A D

(NOT IN CONTRACT) RE: NOTE 6

FUTURE/EXISTING ACCESS ROAD

N

O T

N T

R A

C

F U

T U

R E

E X I

S T I

C E

A D

(NOT IN CONTRACT) RE: NOTE 6

FUTURE/EXISTING ACCESS ROAD

5'8' 5'8' 5'8' 5'8' 5'8'

R

NEW BLDG CANOPY

R

R

NEW STM SWR

R

5' R 3'R

R

R

R

5'R

10'

R

C U

R B

C U

R B

CURB

END 6"CURB

BEGIN 6"

C U

R B

A L

(TYP)

STOPS

NEW PKG

A L

SWR

SAN

NEW

NEW ADMINISTRATION BUILDING

ALL ESS

HOUSTON, TX 77030

2002 HOLCOMBE BOULEVARD,

Revision # Date

DRAWING NUMBER

VA PROJECT NUMBER

DATE

PROJECT TITLE

BUILDING NUMBERPROJECT LOCATION

CHECKED DRAWN

APPROVED: CHIEF ENGINEER

o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t

1 2 3 4 5 6 7 8 9

A

VA FORM 08-6231

Management and Facilities

Construction

Office of

Dwg.

CONSULTANTS

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR

APPROVED: CHIEF ENGINEER

F U

L L

Y S

P R

IN

K L

E R

E D

1 2 3 4 5 6 7 8 9

B

C

D

E

F

A

B

C

D

E

F

SHEET TITLE

STRUCTURAL / CIVIL ENGINEER

(713) 864-2900

HOUSTON, TX 77008

1225 N. LOOP WEST, SUITE 800

H2B, INC.

TX ENGR REGISTRATION NO. F-17591

TX ARCH REGISTRATION NO. BR 2171

580-CSI-110

PROJECT KEY MAP

GARAGE

NEW PARKING

HOLC

OMBE

BLVD

C A

M B

R

ID

G E A

V E

C A

M B

R

ID

G E A

V E

E N

G G

R O

U N

D S

E N

G S

H O

P S

C H

IL

L E

R B

U

IL

D

IN

G

B O

IL

E R P

L A

N T

R E

C C

E N

T E

R /G

Y M

R E S

E A

R C

H

S U

B S

T A

N C

E A

B U

S E

MAI

N

BUI

LDI

NG

H O

U S

E

F

IS

H E

R

A L

M E

D A

E A S

T L

E E

SOUTH LEE

W E S

T L

E E

R

IN

G N E S S A

V E

CATE TERRACE

SHEEHAN

AVE

L E C

A P

IT

A N

C A

M B

R

ID

G E

OLD SP

ANISH TRAIL

N H

C U P

K G L

O T

RETE

NTI

ON

POND

V A

N

R A

M P

A

B

C

D

HOLCOMBE RETAIL CENTER

HOLCOMBE BLVD

VA REGIONAL OFFICE

OLD S

PANIS

H T

RAIL

A L

M E

D A

NTS

40'20'10'0'

SCALE 1" = 20'

N

HORIZONTAL CONTROL

VERTICAL CONTROL

of 956-27-17

BID DOCUMENTS

FIRE PROTECTION / TELECOM ENGINEER

ARCHITECT & M.E.P. ENGINEER

713.864.2900

HOUSTON, TX 77008

1225 N Loop W, Suite 800

Texas Fir Registration No. 8856

H2B, INC.

(512) 472-6721

AUSTIN, TX 78701

400 W. CESAR CHAVEZ STREET, SUITE 500

PAGE

6/27/2017

LEGEND:

NEW WATER LINE

NEW SCOPE PROJECT LIMITS

NEW COMMUNICATION LINE

NEW ELEC LINE

NEW 5' CONCRETE SIDEWALK

NEW STM SWR & JUNCTION BOX

NEW SAN SEWER LINE

NEW DOUBLE OVERHEAD LIGHTING

NEW SINGLE OVERHEAD LIGHTING

EXISTING LEGEND:

IR

S

UNDERGROUND POWER LINE

UNDERGROUND GAS LINE

E

FENCE

SANITARY SEWER

STORM DRAIN

OXYGEN LINE

WATER LINE

WROUGHT IRON FENCE

UNDERGROUND ELECTRIC

WATER VALVE

FIRE HYDRANT

ELECTRIC BOX

LIGHT

LIGHT STANDARD

ELECTRIC MANHOLE

SIGN

SANITARY SEWER MANHOLE

IRRIGATION CONTROL BOX

TELECOMMUNICATION LINE

EXIST ROADWAY REPAIR PROJECT

(TO REMAIN)

PROTECT EXIST ASPHALT

NEW ASPHALT

NEW 5" CONCRETE PAVEMENT

NEW 6" CONCRETE PAVEMENT

NEW CLEANOUT

NEW WATER LINE REDUCER

NEW FIRE HYDRANT ASSEMBLY

NEW GATE VALVE & BOX

NOTES:

SITE LAYOUT PLAN

CS-102

DOWLED ON CURB DETAIL.

9. CONTRACTOR SHALL REFERENCE SHEET CS-201 FOR

DEDUCT ALTERNATE.

8. REFER TO SHEET GI-100 FOR WEST PARKING LOT

OTHER ELECTRICAL FEATURES WITH THE MEP DRAWINGS.

7. CONTRACTOR SHALL COORDINATE LIGHTING AND OTHER

AND DESIGN.

HOUSTON ROAD REPAIRS FOR ROADWAY REALIGNMENT

6. REFER TO VA PROJECT NUMBER 580-16-102, VA

CONNECTIONS WILL OCCUR OUTSIDE THIS LINE.

FOR THIS PROJECT. SOME NECESSARY UTILITY

5. SCOPE LIMIT LINE SHOWS GENERAL LIMITS OF SCOPE

4. SOD OR HYDROMULCH ALL DISTURBED AREAS.

NOTED.

3. ALL RADII SHALL BE 3' UNLESS OTHERWISE

UNLESS OTHERWISE NOTED.

2. ALL DIMENSIONS SHOWN ARE TO FACE OF CURB,

NOTED.

LONG AND 9-FEET WIDE, UNLESS OTHERWISE

1. TYPICAL PARKING STALL SHALL BE 19-FEET

BOX

ELEC PULL

PULL BOX

EXIST TELE CONDUIT

BOX w/SPARE 4"

EXIST ELEC PULL

LIMITS

SHEET

T Y

P

C U R B

R

16'

SCALE FACTOR OF 0.999885781.

CONVERTED TO GRID BY APPLYING THE AVERAGE

NAD83 (2011 ADJ.) AND ARE SURFACE AND CAN BE

COORDINATE SYSTEM SOUTH CENTRAL ZONE, 4204,

OBSERVATIONS THE LIECA GPS NETWORK TEXAS

COORDINATES SHOWN HEREON ARE BASED ON GPS

NAVD 1988, 2001 ADJUSTED

NEAR STREAM D100-00-00 ELEV. 43.68 FEET

CENTER IN KEYMAP 533E IN THE BRAYS WATERSHED

DOWNSTREAM, E. SIDEWALK OF BRIDGE, AT STREAM

S. OF HOLCOMBE BOULEVARD LOCATED ON

BRIDGE AT BRAESWOOD BOULEVARD & BRAYS BAYOU,

AN HCFCD BRASS DISK STAMPED D100 BM14 ON

FLOODPLAIN REFERENCE MARK NUMBER 040105 IS

10'

5'

4.5'

DOWLED

0.5'

CURB

DOWLED0.

5'

CURB

DOWLED

0.5'

CURB

DOWLED0.

5'

CURB

File details come from the government source that posted it. Updated .