02_Davison_Rd_MP_0.01_signed_10_08_26_Plan_Sheets.pdf
PDF 14 MB Posted
- Attached to
- Davison Rd MP 0.01 Bridge Rehabilitation
- Solicitation number
- CRP 2198
- Issued by
- Kittitas County, Washington
About this file
This document is a comprehensive set of plan sheets for the Davison Road Mile Post 0.01 Bridge Rehabilitation project in Lewis County, Washington, prepared by the Lewis County Department of Public Works Engineering-Design Section in coordination with KPFF Consulting Engineers. The project involves the rehabilitation of an existing steel truss bridge over the Tilton River, including cleaning and painting the steel truss span, repairing and strengthening damaged steel members, replacing rivets with high-strength bolts, repairing pack rust, removing and replacing the deck system, replacing expansion joints, and repairing concrete abutments and wing walls. The project is identified as Federal Aid Project No. BHOS-2021(075) with Federal Aid Agreement No. LA 10545 and County Road Project No. 2198. Sealed bids must be submitted by 12:15 PM on Thursday, November 19, 2026, through the Lewis County procurement portal or in person at the Lewis County Clerk's office. The contract documents are available through Lewis County's website at www.lewiscountywa.gov or by contacting the Lewis County Engineers office at (360) 740-1123 Extension 2. The project encompasses six bridge panels with steel truss strengthening work on bottom and top chords, lateral bracing repairs, rivet replacement, and complete deck replacement using treated timber stringers and deck planks with a waterproof membrane system.
A bid proposal deposit equal to five percent of the bid amount must accompany all proposals in the form of cash, certified check, cashier's check, or surety bond. The project is funded through federal aid with a Federal Aid Contract No. TA-7620. The work is designed for specific live load vehicles including AASHTO Types 3, 3S2, and 3-3, specialized hauling vehicles SU4 through SU7, emergency vehicle type EV2, and the WA-105 vehicle, all with impact. Construction sequencing includes four phases: Phase 1 involves installing below-deck work platforms and performing steel repairs with localized containment while maintaining open roadway; Phase 2 closes the bridge for deck replacement; Phases 3 and 4 involve installing full containment systems and painting each side of the truss while maintaining single-lane traffic. The contractor must submit working drawings, calculations, attachment plans, and a demolition plan for engineer approval prior to construction. All materials and workmanship must conform to the Washington State Department of Transportation Standard Specifications for Road, Bridge and Municipal Construction dated 2026, with all steel surfaces requiring full paint removal prior to applying new paint systems.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DAVISON RD MP 0.01 BRIDGE REHABILITATION
FEDERAL AID PROJECT NO: BHOS-2021(075)
FEDERAL AID AGREEMENT NO: LA 10545
COUNTY ROAD PROJECT NO: 2198
APPROVED FOR CONSTRUCTION:
DEPARTMENT OF PUBLIC WORKS
LEWIS COUNTY
ENGINEERING-
DESIGN SECTION
COMMISSIONERS:
SEAN D. SWOPE, DISTRICT 1
LINDSEY R. POLLOCK, DVM, DISTRICT 2
SCOTT J. BRUMMER, DISTRICT 3
STATE ROUTE 506
NOT TO SCALE
VICINITY MAP
LEWIS COUNTY
STATE ROUTE 508
U.S. HIGHWAY 12
PE ELL
VADER
MORTON
PACKWOOD
RANDLE
MOSSYROCK
CENTRALIA
CHEHALIS
NAPAVINE
WINLOCK
TOLEDO
IN
TE
R S
TA
TE
STATE ROUTE 6
DateAssistant County Engineer
STATE ROUTE 505
INTERSTATE 5
ONALASKA
SHEET NO. DESCRIPTION
SHEET INDEX
G1 COVER SHEET
G2 LEGEND AND QUANTITIES
C1 MAINTENANCE OF TRAFFIC PLAN 1
C2 MAINTENANCE OF TRAFFIC PLAN 2
S1 BRIDGE PLAN AND ELEVATION
S2 TRUSS REPAIR ELEVATION
S3 TRUSS REPAIR PLAN
S4 EXISTING TYPICAL SECTION
S5 CONSTRUCTION SEQUENCE
S6 RIVET INSPECTION
S7 BOTTOM CHORD REPAIR DETAILS 1
S8 BOTTOM CHORD REPAIR DETAILS 2
S9 BOTTOM CHORD REPAIR DETAILS 3
S10 LATERAL BRACING REPAIR DETAILS
S11 TOP CHORD REPAIR DETAILS
S12 ABUTMENT REPAIR DETAILS
S13 DECK REPLACEMENT DETAILS
S14 EXPANSION JOINT REPLACEMENT DETAILS
STATE ROUTE 508
EOP PROJECT LOCATION
END PROJECT: Mile Post 0.03
BOP PROJECT LOCATION
BEGIN PROJECT: Mile Post 0.00
N am e:
k yl e.
h ar ve y
D at e:
A ug
1, 6-
:2
4:
p m
F ile
: V
(D av is o n R d B ri d g e
R eh ab
_D es ig n (v
D
R B
-G 1_
C o ve r
S h ee t.
d w g
10/08/2026
WRAnderson Text Box
FEDERAL AID CONTRACT NO. TA-7620
VHall
PE 01
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:2 6:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -G
2_ Le g en d
Q ua nt iti es .d w g
08-28-20262
GENERAL NOTES
1. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE WASHINGTON STATE DEPARTMENT OF
TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION, DATED 2026, AND AMENDMENTS, AND
PROJECT SPECIAL PROVISIONS.
2. CONSTRUCTION AND WIND LOADING LIMITATIONS DURING PAINTING ACTIVITIES HAVE BEEN DETERMINED IN ACCORDANCE WITH AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, 10TH EDITION AND CHAPTER 6 OF THE WSDOT BRIDGE DESIGN MANUAL M 23-50.24.
3. THE DIMENSIONS SHOWN ON THE PLANS ARE BASED ON ORIGINAL DESIGN DRAWINGS AND INSPECTIONS. ALL RELEVANT DETAILS AND DIMENSIONS SHALL BE FIELD MEASURED AND VERIFIED BY THE CONTRACTOR PRIOR TO ORDERING MATERIALS AND PROCEEDING WITH
CONSTRUCTION.
4. PAINTING SHALL BE COMPLETED IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION SECTION 6-07. ALL STEEL SURFACES REQUIRE FULL PAINT REMOVAL PRIOR TO APPLYING NEW PAINT SYSTEM. SEE WSDOT STANDARD SPECIFICATION SECTION 6-07.3(10)E FOR SURFACE
PREPARATION REQUIREMENTS.
5. EXISTING RIVETS SHALL BE INSPECTED AFTER ABRASIVE BLASTING OPERATIONS ARE COMPLETED AND SHALL BE REMOVED AND REPLACED IN
ACCORDANCE WITH SECTION - LOSS CRITERIA ON SHEET S6.
6. THE CONTRACTOR SHALL PLAN AND CONDUCT THE WORK IN SUCH A MANNER THAT NO OBJECTS OR FOREIGN MATERIALS FALL FROM THE WORK ON THE EXISTING SPANS AND SUPPORTS TO THE RIVER CHANNEL BELOW. THE CONTRACTOR'S PLAN FOR ACCOMPLISHING THIS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO THE START OF CONSTRUCTION. ALL WORK ASSOCIATED WITH THIS CONTAINMENT
SYSTEM SHALL BE CONSIDERED INCIDENTAL TO THE CONTRACT.
7. BRIDGE IMPROVEMENTS ARE DESIGNED FOR THE FOLLOWING LIVE LOAD VEHICLES:
- AASHTO TYPE 3 WITH IMPACT
- AASHTO TYPE 3S2 WITH IMPACT
- AASHTO TYPE 3-3 WITH IMPACT
- SPECIALIZED HAULING VEHICLE SU4 WITH IMPACT
- SPECIALIZED HAULING VEHICLE SU5 WITH IMPACT
- SPECIALIZED HAULING VEHICLE SU6 WITH IMPACT
- SPECIALIZED HAULING VEHICLE SU7 WITH IMPACT
- EMERGENCY VEHICLE TYPE EV2 WITH IMPACT
- WA-105 WITH IMPACT
8. ALL STEEL ELEMENTS SHALL CONFORM TO:
PLATES AND ROLLED SHAPES: ASTM A992 (50 KSI)
BOLTS: ASTM F3125 GRADE A325, TYPE 1
NUTS: ASTM A563
WASHERS: ASTM F436
9. ALL CONCRETE ELEMENTS SHALL CONFORM TO:
CONCRETE: CLASS 4000
REINFORCEMENT: ASTM A706 GRADE 60
CHAMFER 3/4 INCH
VIEW OR DETAIL
THE SAME SHEET
TAKEN OR SHOWN
IDENTIFIES SECTION,
ON SHEET NO S7
LEGEND
TAKEN OR SHOWN ON
S7
ABBREVIATIONS
LEGEND AND QUANTITIES
G2
@ AT
± PLUS OR MINUS
BK BACK
BOT BOTTOM
BTWN BETWEEN
CL CENTERLINE
EX EXISTING
GR GRADE
HMA HOT MIX ASPHALT
MT MAGNETIC PARTICLE TESTING
NO. NUMBER
NTS NOT TO SCALE
OHWM ORDINARY HIGH WATER MARK
PL PLATE
PSF POUNDS PER SQUARE FOOT
TYP TYPICAL
C L
B R
ID
G
E C
L R
O A
D W
A Y
SR 508
SEE NOTE 3
XX
4'
MI
N
TY
P.
WORK
AREA
R11-2
48"
30"
50 TO 100 FTX/2X/2X
W20-301
48"
48"
SHOULDER
CLOSED
W20-1
48"
48"
ROAD
WORK
AHEAD
W21-5
48"
48"
SHOULDER
WORK
W4-1BIKE
48"
48"
BIKES
MERGE WITH
TRAFFIC
4'
MI
N
TY
P.
ROAD
CLOSED
R11-1501
PLACE SIGN 30 DAYS
BEFORE CLOSURE
48"
60"
ROAD
WILL BE
CLOSED
day/mo - day/mo x:xxPM-x:xxAM
B
VARIES SEE NOTE 2
W16-8P VAR" x 8"
DAVIDSON RD
W20-1
48"
48"
ROAD
WORK
AHEAD
W20-3
48"
48"
ROAD
CLOSED
AHEAD
W16-8P VAR" x 8"
DAVIDSON RD
W20-3
48"
48"
ROAD
CLOSED
AHEAD
X
D A
V
IS
O N
R D
W20-3
48"
48"
ROAD
CLOSED
AHEAD
R11-2
48"
30"
W20-1
48"
48"
ROAD
WORK
AHEAD
SET ROAD CLOSURE AT
FIRST DRIVEWAY FROM
BRIDGE
R11-1501
PLACE SIGN 7 DAYS
BEFORE CLOSURE
48"
60"
ROAD
WILL BE
CLOSED
xx/xx - xx/xx x:xxPM-x:xxAM
ROAD
CLOSED
4' MIN
TYP.
X X
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : TES
DRAWN BY : TES
CHECKED BY : KAI
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
t h eo .s ch m itt D at e:
S ep
2, 6-
:3 1:
p m F ile
\k p ff .c o m
\C iv il\
1-
9\
D av is o n
R d
B ri d g e R eh ab ili ta tio n\
C A
D D
\D es ig n\
D R
B -C
1.
d w g
LEGEND
TEMPORARY SIGN LOCATION (1' MIN HEIGHT)
CHANNELIZING DEVICE (SEE NOTE 3)
MAINTENANCE OF TRAFFIC PLAN 1
C1
2'LANE OPEN
TO TRAFFIC
LANE OPEN
TO TRAFFIC
45 50 55 60
150 200 200 200
SPEED (MPH) 65
24010'
SHOULDER CLOSURE TAPER LENGTH = L/3
160 160 160 200
SHOULDER
WIDTH
< 8' 8' L/3 (feet) 120
USE LANE CLOSURE INSTEAD
60 6550SPEED (MPH)
B (feet)
425 495 570 645
LONGITUDINAL BUFFER SPACE = B
Buffer space may be adjusted (192) based on field conditions.
800' * 500' *
60-65 MPH
45-55 MPH
RURAL HIGHWAYS
RURAL ROADS
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE
INTERSECTIONS AND DRIVEWAYS.
RECOMMENDED SIGN SPACING = X (1)
SEE NOTE 3
EXISTING
SHOULDER
SHOULDEREXISTING
LANE
EXISTING
LANE
30 60
TANGENTMPH TAPER
MAXIMUM CHANNELIZATION
DEVICE SPACING (feet)
8050 - 65
172'123'
45-55 MPH 60+ MPH
HOST VEHICLE WEIGHT
LESS THAN 22,000 lbs.
45-55 MPH 60+ MPH
100' 150'
HOST VEHICLE WEIGHT
22,000+ lbs.
STATIONARY TRANSPORTABLE ATTENUATOR
ROLL AHEAD DISTANCE = R
8. PEDESTRIAN ACCOMMODATIONS, WHERE FACILITY OPEN TO PEDESTRIANS:
(A) KEEP ADJACENT SIDEWALK OR PATHWAY OPEN.
(B) CLOSE ADJACENT SIDEWALK OR PATHWAY. PROVIDE PEDESTRIAN DETOUR, ALTERNATE ROUTE, OR
FREE SHUTTLE (WORK TRUCK, VAN, OR BUS OK).
(C) STOP WORK OPS. & ESCORT PEDESTRIANS THROUGH WORK AREA.
(D) ENGINEER TO ACCEPT ANY ALTERNATIVE STRATEGIES.
9. BICYCLIST ACCOMMODATIONS, WHERE FACILITY OPEN TO BICYCLES:
(A) SHARED BICYCLE-VEHICLE LANE. ADD W11-15 MOD & R4-11 SIGNS.
(B) BICYCLES PROHIBITED VIA R5-601 (IF EXIT-RAMP PRESENT) & R5-6 SIGNS. PROVIDE SIGNED DETOUR
OR ALTERNATIVE ROUTE.
(C) BICYCLES PROHIBITED VIA R5-6 SIGN(S). PROVIDE FREE SHUTTLE (WORK TRUCK, VAN, OR BUS OK) +
CONTACT INFORMATION/PHONE BOX/LABORER.
(D) STOP WORK OPS. & ESCORT BICYCLISTS THROUGH SHOULDER CLOSURE.
(E) ENGINEER TO ACCEPT ANY ALTERNATIVE STRATEGIES.
NOTES:
1. IF FEASIBLE, AVOID PLACING SHOULDER CLOSURE TAPER WITHIN OR IMMEDIATELY FOLLOWING
HORIZONTAL AND VERTICAL CREST CURVES.
2. DISTANCE INCREASES AS WORK AREA MOVES DOWNSTREAM.
3. 28" TRAFFIC CONE, 36" TRAFFIC CONES, 42" TALL CHANNELIZING DEVICES, OR TRAFFIC SAFETY
DRUMS ALLOWED ON TAPERS AND TANGENTS. ENCROACHMENT INTO ADJACENT OPEN LANE
PROHIBITED (BASE WEIGHT MAY ENCROACH). USE 5' MIN MOUNTING HEIGHT ON TEMPORARY
SIGNS PLACED BEHIND TRAFFIC SAFETY DRUMS.
4. FOR SIGNS PLACED BEHIND TRAFFIC SAFETY DRUMS, USE 5-FOOT MOUNTING HEIGHT.
5. RED/WHITE OR BLACK/YELLOW CHEVRON PATTERN OK. ADDITIONAL TRANSPORTABLE ATTENUATORS
MAY BE ADDED BEHIND EACH WORK CREW.
6. IF PAVED SHOULDER IS LESS THAN 8 FEET WIDE AT TRANSPORTABLE ATTENUATORS AND WORK
AREA, THEN A LANE CLOSURE SHALL BE IMPLEMENTED.
7. SIGNS ARE BLACK ON ORANGE UNLESS OTHERWISE INDICATED.
LEGEND
TEMPORARY SIGN LOCATION (1' MIN HEIGHT)
CHANNELIZING DEVICE (SEE NOTE 3)
A
A
09/02/26
L
B R
ID
G
E C
L R
O A
D W
A Y
SR 508
SEE NOTE 3
WORK
AREA
10.0'
W20-1
48"
48"
ROAD
WORK
AHEAD
X
B
VARIES SEE NOTE 2
50 TO 100 FTX/2X/2X
W20-301
48"
48"
SHOULDER
CLOSED
W20-1
48"
48"
ROAD
WORK
AHEAD
20 FT
W21-5
48"
48"
SHOULDER
WORK
W4-1BIKE
48"
48"
BIKES
MERGE WITH
TRAFFIC
A
B
4'
MI
N
TY
P.
4'
MI
N
TY
P.
D A
V
IS
O N
R D
10.0'
17.0'
BUFFER SPACE
(OPTIONAL)
50 TO
100 FT
15 FT
100 FT
100 FT
100 FT
TO
ONCOMING
TRAFFIC
R1-2
R1-2AP
W3-2
48"
48"
W20-4
48"
48"
ONE LANE
ROAD
AHEAD
W20-1
48"
48"
ROAD
WORK
AHEAD4' MIN
TYP.
36"
18"
24"
YIELD
75 FT
STAGING AREA
2'LANE OPEN
TO TRAFFIC
LANE OPEN
TO TRAFFIC
45 50 55 60
150 200 200 200
SPEED (MPH) 65
24010'
SHOULDER CLOSURE TAPER LENGTH = L/3
160 160 160 200
SHOULDER
WIDTH
< 8' 8' L/3 (feet) 120
USE LANE CLOSURE INSTEAD
60 6550SPEED (MPH)
B (feet)
425 495 570 645
LONGITUDINAL BUFFER SPACE = B
Buffer space may be adjusted (192) based on field conditions.
800' * 500' *
60-65 MPH
45-55 MPH
RURAL HIGHWAYS
RURAL ROADS
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE
INTERSECTIONS AND DRIVEWAYS.
RECOMMENDED SIGN SPACING = X (1)
SEE NOTE 3
EXISTING
SHOULDER
SHOULDEREXISTING
LANE
EXISTING
LANE
30 60
TANGENTMPH TAPER
MAXIMUM CHANNELIZATION
DEVICE SPACING (feet)
8050 - 65
172'123'
45-55 MPH 60+ MPH
HOST VEHICLE WEIGHT
LESS THAN 22,000 lbs.
45-55 MPH 60+ MPH
100' 150'
HOST VEHICLE WEIGHT
22,000+ lbs.
STATIONARY TRANSPORTABLE ATTENUATOR
ROLL AHEAD DISTANCE = R
8. PEDESTRIAN ACCOMMODATIONS, WHERE FACILITY OPEN TO PEDESTRIANS:
(A) KEEP ADJACENT SIDEWALK OR PATHWAY OPEN.
(B) CLOSE ADJACENT SIDEWALK OR PATHWAY. PROVIDE PEDESTRIAN DETOUR, ALTERNATE ROUTE, OR
FREE SHUTTLE (WORK TRUCK, VAN, OR BUS OK).
(C) STOP WORK OPS. & ESCORT PEDESTRIANS THROUGH WORK AREA.
(D) ENGINEER TO ACCEPT ANY ALTERNATIVE STRATEGIES.
9. BICYCLIST ACCOMMODATIONS, WHERE FACILITY OPEN TO BICYCLES:
(A) SHARED BICYCLE-VEHICLE LANE. ADD W11-15 MOD & R4-11 SIGNS.
(B) BICYCLES PROHIBITED VIA R5-601 (IF EXIT-RAMP PRESENT) & R5-6 SIGNS. PROVIDE SIGNED DETOUR
OR ALTERNATIVE ROUTE.
(C) BICYCLES PROHIBITED VIA R5-6 SIGN(S). PROVIDE FREE SHUTTLE (WORK TRUCK, VAN, OR BUS OK) +
CONTACT INFORMATION/PHONE BOX/LABORER.
(D) STOP WORK OPS. & ESCORT BICYCLISTS THROUGH SHOULDER CLOSURE.
(E) ENGINEER TO ACCEPT ANY ALTERNATIVE STRATEGIES.
NOTES:
1. IF FEASIBLE, AVOID PLACING SHOULDER CLOSURE TAPER WITHIN OR IMMEDIATELY FOLLOWING
HORIZONTAL AND VERTICAL CREST CURVES.
2. DISTANCE INCREASES AS WORK AREA MOVES DOWNSTREAM.
3. 28" TRAFFIC CONE, 36" TRAFFIC CONES, 42" TALL CHANNELIZING DEVICES, OR TRAFFIC SAFETY
DRUMS ALLOWED ON TAPERS AND TANGENTS. ENCROACHMENT INTO ADJACENT OPEN LANE
PROHIBITED (BASE WEIGHT MAY ENCROACH). USE 5' MIN MOUNTING HEIGHT ON TEMPORARY
SIGNS PLACED BEHIND TRAFFIC SAFETY DRUMS.
4. FOR SIGNS PLACED BEHIND TRAFFIC SAFETY DRUMS, USE 5-FOOT MOUNTING HEIGHT.
5. RED/WHITE OR BLACK/YELLOW CHEVRON PATTERN OK. ADDITIONAL TRANSPORTABLE ATTENUATORS
MAY BE ADDED BEHIND EACH WORK CREW.
6. IF PAVED SHOULDER IS LESS THAN 8 FEET WIDE AT TRANSPORTABLE ATTENUATORS AND WORK
AREA, THEN A LANE CLOSURE SHALL BE IMPLEMENTED.
7. SIGNS ARE BLACK ON ORANGE UNLESS OTHERWISE INDICATED.
LEGEND
TEMPORARY SIGN LOCATION (1' MIN HEIGHT)
CHANNELIZING DEVICE (SEE NOTE 3)
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : TES
DRAWN BY : TES
CHECKED BY : KAI
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
t h eo .s ch m itt D at e:
S ep
2, 6-
:3 6:
p m F ile
\k p ff .c o m
\C iv il\
1-
9\
D av is o n
R d
B ri d g e R eh ab ili ta tio n\
C A
D D
\D es ig n\
D R
B -C
2.
d w g
1'10' LANE OPEN
TO TRAFFIC
SEE NOTE 3
6' WORK AREA
BA
MAINTENANCE OF TRAFFIC PLAN 2
C2
TEMPORARY MISC. PAVEMENT
MARKING - LONG DURATION
INSTALL TYPE 1 YIELD LINE
SYMBOL PER WSDOT STD PLAN
M-24.60
09/02/26
CL BRIDGE
CL ROADWAY
103'-31
2" BK TO BK PAVT SEAT
S R
'-0
R
O A
D W
A Y
TI
LT
O N
R
IV
E R
EXISTING STEEL TRUSS BRIDGE NO. 210000001
CLEAN AND PAINT STEEL TRUSS SPAN, REPAIR DAMAGED STEEL, STRENGTHEN STEEL
MEMBERS, REPLACE RIVETS, REPAIR PACK RUST, REMOVE AND REPLACE DECK SYSTEM
EXPANSION JOINT
REPLACEMENT
(SEE S14)
EXPANSION JOINT
REPLACEMENT
(SEE S14)
DAVISON RD
EXISTING FENCE
DEMOLISH AND
REBUILD CONCRETE
WING WALL (SEE S12)
CONCRETE
ABUTMENT, TYP
STEEL TRUSS
ROADWAY
CONCRETE SLAB
100'-0" CL TO CL BEARING
OHWM
EL 844
T/DECK
EL 856± (REPLACEMENT TO MATCH EXISTING)
CONTRACTOR STAGING AREA
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
S ep
2, 6-
:0 9:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
1_ P la n an d
E le va tio n.
d w g
08-28-2026
PLAN
ELEVATION (LOOKING WEST)
0 4' 8' 16'
1/8 inch = 1 foot
24' (96)
0 4' 8' 16'
1/8 inch = 1 foot
24' (96)
SEC. 33, T.13N, R.04E, W.M.
BRIDGE PLAN AND ELEVATION
S1
6' -0
TY
P
8' -8
TY
P 10
'-0
TY
P
L2A L4A L6A L8A L10A
U1A
U2A
U3A U4A
U5A U6A U7A U8A
U9A
U10A
U11A
L12A
CL THRIE BEAM
ROADWAY
STEEL TRUSS MEMBER,
TYP
(6) PANELS @ 16'-8" CL - CL BEARING
INSIDE VIEW OF WEST TRUSS
L0A
EXISTING
CONCRETE
SLAB
REPLACE RIVETS WITH
HIGH STRENGTH BOLTS
AT L4A AND L8A GUSSET
PLATES (SEE S6)
CONCRETE
ABUTMENT, TYP
STRENGTHEN
L2A-L10A (SEE S7)
STRENGTHEN
U3A-U5A (SEE S11)
STRENGTHEN
U7A-U9A (SEE S11)
6' -0
TY
P
8' -8
TY
P 10
'-0
TY
P
L2B L4B L6B L8B L10B
U1B
U2B
U3B U4B
U5B U6B U7B U8B
U9B
U10B
U11B
L12B
CL THRIE BEAM
ROADWAY
STEEL TRUSS MEMBER, TYP
(6) PANELS @ 16'-8" CL - CL BEARING
OUTSIDE VIEW OF EAST TRUSS
L0B
SEAL PACK
RUST U7B
EXISTING
CONCRETE
SLAB
REPLACE RIVETS WITH
HIGH STRENGTH BOLTS
AT L4B AND L8B GUSSET
PLATES (SEE S6)
STEEL REPAIR
L6B-L8B (SEE S8)
SEAL PACK
RUST L10B
CONCRETE
ABUTMENT, TYP
STRENGTHEN
L2B-L8B (SEE S7)
STRENGTHEN
U3B-U5B (SEE S11)
STRENGTHEN
U7B-U9B (SEE S11)
EXISTING BOLSTER
STRENGTHENED
BOTTOM CHORD
STRENGTHENED
BOTTOM CHORD
STEEL REPAIR
L10B-L12B (SEE S9)
STEEL REPAIR
L8A-L10A (SEE S9)
STRENGTHEN
U5A-U7A (SEE S11)
STRENGTHEN
U5A-U7A (SEE S11)
H S4
G S4
I S4
C S4
D S4
J S4
E S4
F S4
STRENGTHENED
TOP CHORD, TYP
STRENGTHENED
TOP CHORD, TYP
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:3 3:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
2_ Tr us s
R ep ai r
E le va tio n.
d w g
08-28-2026
NOTES:
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD.
TRUSS REPAIR ELEVATION
S2
8'4'2'0
1/4 inch = 1 foot
12'
8'4'2'0
1/4 inch = 1 foot
12'
'-4
C
L
C L
TR
U
S S
1' -0
T
Y P
(1 0)
E X
IS
TI
N G
T
IM
B E
R S
TR
IN
G E
R S
P E
R B
A Y
T O
B E
R E
M O
V E
D
CHORD, TYP
FLOOR BEAM, TYP
TIMBER BRACE TO
BE REMOVED, TYP PANEL POINT, TYP
PANEL 3
L3 12x2 12x
16 BRACING, TYP,
REPLACE BRACING AND HEAT STRAIGHTEN GUSSET
PLATE ATTACHMENT POINTS, PANELS 3 THROUGH 6
(8 TOTAL BRACES, SEE S10)A
S4
EXISTING FRAMING PLAN
PANEL 1 PANEL 2 PANEL 4 PANEL 5 PANEL 6
L0 L2 L4 L6 L8 L10 L12
4"
TYP
EXISTING TIMBER
STRINGER SPLICE TO BE
REMOVED, TYP
BELOW DECK FRAMING - EXISTING CONDITION 1
-NTS
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:3 4:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
3_ Tr us s
R ep ai r
P la n.
d w g
08-28-2026
NOTES:
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD.
2. TYPICAL EXISTING STRINGER SPACING IS 2'-0". SPACING
BETWEEN EXTERIOR AND FIRST INTERIOR STRINGER VARIES
BETWEEN BAYS BY THE WIDTH OF THE STRINGER.
3. TIMBER DECK AND STRINGERS TO BE REPLACED. SEE S13
FOR DECK AND STRINGER REPLACEMENT DETAILS.
4. CONTRACTOR TO SUBMIT DEMOLITION PLAN TO ENGINEER.
TRUSS REPAIR PLAN
S3
8'4'2'0
1/4 inch = 1 foot
12'
1'-4"
3"
1/
2"
3/
4"
9 3/4"
3"
5"
9 3/4"
3"
4"
9 3/4"
2 1/2"
1/
2"
7"
5/8"
1' -8
3/
TYPICAL
FLOOR BEAM B
-SCALE: NTS
I20x81.4 BEAM
TOP CHORD: L0-U5
AND U7-L12 E
S2SCALE: NTS
STEEL PL
VERTICALS: ALL G
S2SCALE: NTS
L3x2 1/2x5/16, TYP
DIAGONAL: U1-L2
AND L10-U11 H
S2SCALE: NTS
L5x3x5/16, TYP
DIAGONAL: L2-U3
AND U9-L10 I
S2SCALE: NTS
DIAGONAL: U3-L4,
L4-U5, U5-L6, L6-U7, U7-L8 AND L8-U9 J
S2SCALE: NTS
L3 1/2x2 1/2x5/16, TYPL4x3x5/16, TYP
5/16"
C10x15.3
SEE BOTTOM
CHORD L0-L4 &
L8-L12
DETAIL FOR
DIMENSIONS,
TYP.
5/
" 1'-4"
TOP CHORD: U5-U7 F
S2SCALE: NTS
STEEL PL
C10x15.3
SEE BOTTOM
CHORD L0-L4 &
L8-L12
DETAIL FOR
DIMENSIONS,
TYP.
3/ 8"
9 3/4" 9 3/4"
BOTTOM CHORD:
L0-L4 & L8-L12 C
S2SCALE: NTS
BOTTOM CHORD:
L4-L8 D
S2SCALE: NTS
C10x15.3, TYP C10x20, TYP
2 5/8" 2 3/4"
19'-4" CL TO CL TRUSS
EXISTING ASPHALT
OVERLAY TO BE
REMOVED
EXISTING 4x6
TIMBER BULL
RAIL, TYP
TO BE REMOVED
EXISTING 4x6
TIMBER BULL RAIL
SUPPORT, TYP
TO BE REMOVED
EXISTING (10) 6x16
TIMBER STRINGERS
TO BE REMOVED
EXISTING THRIE BEAM
GUARDRAIL TO BE
TEMPORARILY
REMOVED AND RESET
FOR PAINTING, TYP
EXISTING 2x6
TIMBER BRACE
AT MIDSPAN TO
BE REMOVED
EXISTING 2 1/2" TIMBER
SHIM BETWEEN STRINGERS
AND FLOOR BEAM TO BE
REMOVED
EXISTING STEEL
I20x81.4 FLOOR BEAM
EXISTING STEEL
TRUSS MEMBERS, TYP
EXISTING TYPICAL DECK SECTION A
S3SCALE: 1/2" = 1'-0"
17'-0" CLEAR WIDTH
B
NOTES:
1. PRIMARY MEMBER DIMENSIONS ARE BASED ON ORIGINAL BRIDGE PLANS AND FIELD
DIMENSIONS TAKEN ON 03/25/2024 AND 03/26/2024.
2. STEEL LATTICE PLATES, COVER PLATES, AND BRACE PLATES NOT SHOWN FOR CLARITY.
3. REPLACEMENT DETAILS ARE SHOWN ON S13.
EXISTING TIMBER DECK
PLANKS TO BE REMOVED
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:3 7:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
4_ Ty p ic al S ec tio n.
d w g
08-28-20268
EXISTING TYPICAL SECTION
S4
1. TEMPORARY BARRIERS OTHER THAN THOSE SHOWN ARE NOT ALLOWED ON
THE TRUSS SPAN DURING CONSTRUCTION.
2. THE WEIGHT OF CONTAINMENT SYSTEM AND ABOVE-DECK CONSTRUCTION
LOADS SUCH AS SCAFFOLDING AND PAINTING EQUIPMENT MAY BE
SUPPORTED WITHIN THE WORK AREA SHOWN IN THE TYPICAL SECTION ON
THIS SHEET. CONSTRUCTION LOADS MAY BE PLACED ANYWHERE ALONG THE
LENGTH OF THE BRIDGE AS LONG AS TOTAL LOAD ON BRIDGE DECK AND
BELOW DECK WORK PLATFORM DO NOT EXCEED 25 PSF AND MEET THE
REQUIREMENTS OUTLINED IN NOTE 3. CONSTRUCTION LOADS ARE IN ADDITION
TO THE EXISTING POSTED LOAD LIMITS.
3. TEMPORARY BELOW-DECK WORK PLATFORM:
A. THE CONTRACTOR MAY SUPPORT A TEMPORARY BELOW-DECK PLATFORM
FROM THE TRUSS SPAN. THE WIDTH OF THE PLATFORM SHALL NOT EXCEED
THE OUT-TO-OUT WIDTH OF THE BRIDGE PLUS 5-FEET ON EITHER SIDE. SEE
NOTE F FOR BELOW-DECK PLATFORM LIMITS ALONG THE LENGTH OF THE
BRIDGE.
B. THE TOTAL WEIGHT OF THE BELOW-DECK PLATFORM (SELF WEIGHT, PLUS
IMPOSED LOADS) SHALL NOT EXCEED 20 PSF BASED ON A 30'-8" PLATFORM
WIDTH .
C. WHILE THE BELOW-DECK WORK PLATFORM IS IN PLACE, THE TRIBUTARY
WEIGHT OF ABOVE-DECK CONSTRUCTION LOADS TO ANY OF THE LOWER
PANEL POINTS, WITHIN THE CORRESPONDING CONSTRUCTION LOADING
ZONE, SHALL NOT EXCEED 2500 POUNDS.
D. THE PLATFORM MAY BE SUSPENDED FROM THE FLOOR BEAMS. IMPOSED
POINT LOADS SHALL NOT EXCEED 2500 LBS AND BE NO CLOSER THAN 5' ON
CENTER.
E. THE PLATFORM MAY BE SUSPENDED FROM THE TRUSS IF SUPPORT POINTS
ARE LOCATED AT THE LOWER PANEL POINTS ONLY. NO ATTACHMENT SHALL
BE MADE TO TRUSS MEMBERS BETWEEN PANEL POINTS.
F. PRIOR TO ALL STRENGTHENING BEING COMPLETE, THE LENGTH OF THE
BELOW DECK PLATFORM IS LIMITED TO 2 PANELS (SEE PLAN VIEW FOR PANEL
DEFINITIONS.)
G. AFTER ALL STRENGTHENING IS COMPLETE, THE BELOW DECK PLATFORM MAY
BE PLACED ALONG THE ENTIRE LENGTH OF THE BRIDGE.
4. THE MAXIMUM REACTION AT ANY PANEL POINT ATTACHMENT SHALL NOT
EXCEED 5,000 POUNDS.
5. ATTACHMENT TO THE BRIDGE SHALL BE MADE WITH CLAMP OR PADDED WRAP
TYPE CONNECTORS. HOLES SHALL NOT BE MADE IN BRIDGE MEMBERS. NO
WELDING TO BRIDGE IS ALLOWED. METHODS OF ATTACHMENT TO THE BRIDGE
SHALL BE SUBMITTED IN ACCORDANCE WITH THE STANDARD SPECIFICATION
SECTION 6-07.3(2)F. CONTRACTOR TO SUBMIT ATTACHMENT PLAN. PLAN
SHALL INCLUDE CALCULATIONS SIGNED BY A PROFESSIONAL ENGINEER IN
THE STATE OF WASHINGTON DEMONSTRATING CONNECTORS WILL NOT
DAMAGE BRIDGE MEMBERS LOCALLY.
6. WORKING DRAWINGS AND CALCULATIONS (TYPE 2E) SHALL BE SUBMITTED IN
ACCORDANCE WITH STANDARD SPECIFICATION SECTION 1-05.3. WORKING
DRAWINGS AND CALCULATIONS SHALL SHOW THAT ALL THE ABOVE
CONSTRAINTS HAVE BEEN MET. CONSTRUCTION LOADS SHALL NOT BE PLACED
ON THE BRIDGE UNTIL THE ASSOCIATED WORKING DRAWINGS AND
CALCULATIONS HAVE BEEN REVIEWED AND ACCEPTED BY THE ENGINEER.
7. REMOVED PAINT, DEBRIS AND SPENT ABRASIVE BLAST MEDIA SHALL BE
COLLECTED AND REMOVED FROM THE BRIDGE DAILY, AT A MINIMUM, IN
ACCORDANCE WITH STANDARD SPECIFICATION 6-07.3(10)F.
8. VERTICAL COMPONENTS OF THE CONTAINMENT SYSTEM (TARPS) SHALL BE
REMOVED WHEN WIND SPEEDS (GUST) EXCEED OR ARE FORECASTED TO
EXCEED 50 MILES PER HOUR OR 1" PRECIPITATION OF RAIN IS FORECASTED
OVER A 24-HR PERIOD. SEE SPECIAL PROVISIONS FOR WEATHER SOURCE
REQUIREMENTS.
9. DURING HEAT STRAIGHTENING OF THE BOTTOM CHORD, ONLY ONE LANE OF
TRAFFIC ON THE OPPOSITE TRUSS SIDE OF THE HEAT STRAIGHTENING
LOCATION SHALL BE ALLOWED.
10. NO VEHICLE SHALL EXCEED THE CURRENT POSTED LIMITS UNTIL AFTER ALL
CONSTRUCTION ACTIVITIES ARE COMPLETE.
CONSTRUCTION LOADING NOTES FOR TRUSS SPAN:
19'-4" CL TO CL TRUSS
EXISTING (10) 6x16
TIMBER STRINGERS
EXISTING 2x6
TIMBER BRACE
AT MIDSPAN
EXISTING 2 1/2" TIMBER
SHIM BETWEEN STRINGERS
AND FLOOR BEAM
EXISTING STEEL
I20x81.4 FLOOR BEAM
CONTAINMENT
AND WORK LIMITS,
SEE NOTE 8
LIMITS OF BELOW-DECK WORK
PLATFORM (SEE NOTE 3A)
5' -0
M
A X
5'-0"
MAX, TYP
3' -0
M A
X , T
Y P
RIGID WALLS EACH
PHASE, TYP
5'-0" 2'-0" 10'-0"
TEMPORARY
BARRIER
WEST WORK ZONE AND CONTAINMENT SHOWN,
EAST WORK ZONE AND CONTAINMENT SIMILAR.
APPROX EL 845.3
ABOVE DECK CONSTRUCTION
LOADS ZONE, SEE NOTE 2
BRIDGE SECTION DURING CONSTRUCTION
SCALE: 1/2" = 1'-0"
PHASE 1: INSTALL BELOW DECK WORK
PLATFORM, PERFORM STEEL REPAIRS, AND
PROVIDE LOCALIZED CONTAINMENT AS
REQUIRED FOR STEEL REPAIRS
OPEN ROADWAY
PHASE 2: REPLACE BRIDGE DECK.
BRIDGE CLOSED TO ALL TRAFFIC.
DECK REPLACEMENT AREA
PHASE 3: INSTALL CONTAINMENT FOR WEST
WORK ZONE AND PAINT WEST SIDE OF TRUSS
OPEN ROADWAY
PHASE 4 INSTALL CONTAINMENT FOR EAST
WORK ZONE AND PAINT EAST SIDE OF TRUSS
OPEN ROADWAY
CONSTRUCTION SEQUENCE
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:3 8:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
5_ C o ns tr uc tio n
S eq ue nc e.
d w g
08-28-20269
CONSTRUCTION SEQUENCE
S5
EXAMPLE OF PRIMARILY SHEAR
EXAMPLE OF
PRIMARILY TENSION
EXAMPLE OF TENSION
& SHEAR
RIVET LOADING CONDITION - PRIMARILY SHEAR
A
D
A
H
D
H
RIVET LOADING CONDITION PRIMARILY
TENSION, TENSION & SHEAR, OR UNKNOWN
5/8"
LOADING: TENSION & SHEAR,
TENSION OR UNKNOWN
MINIMUM RIVET DIMENSIONS
LOADING: PRIMARILY
SHEAR
RIVET SHANK
DIAMETER "D"
MINIMUM HEAD
DIAMETER "A"
MINIMUM HEAD
HEIGHT "H"
MINIMUM HEAD
DIAMETER "A"
MINIMUM HEAD
HEIGHT "H"
3/4"
7/8"
7/8"
1"
1 1/8"
3/16"
1/4"
3/8"
1"
1 1/8"
1 1/4"
3/8"
7/16"
9/16"
ORIGINAL RIVET HEAD
PROFILE, TYP
CORRODED RIVIT
HEAD PROFILE, TYP
RIVETED PARTS
RIVET, TYP
RIVET, TYP
RIVET, TYP
dd
ORIGINAL RIVET HEAD
PROFILE, TYP
CORRODED RIVET HEAD
PROFILE, TYP
RIVETED PARTS
dd
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:3 9:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
6_ R iv et
In sp ec tio n.
d w g
08-28-2026
1. EXISTING RIVETS TO REMAIN ON MEMBERS AND/OR GUSSETS SHALL BE EVALUATED
AFTER FIELD PREPARATION FOR PAINTING AND PRIMING IS COMPLETED AND SHALL BE
REMOVED AND REPLACED IN ACCORDANCE WITH THE RIVET EVALUATION CRITERIA
SHOWN ON THIS SHEET. NEW H.S. BOLTS SHALL BE INSTALLED AND TENSIONED IN
ACCORDANCE WITH WSDOT STANDARD SPECIFICATION SECTION 6-03.3(33), AND
PREPARED FOR PAINT IN ACCORDANCE WITH SECTION 6-07.3(11)A.
2. BOLTS SHALL CONFORM TO ASTM F3125 GR A325 AND SHALL BE GALVANIZED. BOLTS
REPLACING RIVETS SHALL HAVE A DIAMETER MATCHING THE DIAMETER OF THE RIVET
THEY REPLACE. EXISTING HOLES MAY BE REAMED TO THE RIVET DIAMETER PLUS 1/8"
MAXIMUM TO FACILITATE BOLT INSTALLATION IF NEEDED.
3. UNLESS OTHERWISE SHOWN IN THE PLANS OR APPROVED BY THE ENGINEER, ONLY ONE
RIVET MAY BE REMOVED AND REPLACED AT A TIME AT ANY MEMBER CONNECTION. THE
REPLACEMENT BOLT SHALL BE FULLY INSTALLED AND TENSIONED BEFORE THE NEXT
RIVET MAY BE REMOVED.
4. PRIOR TO STARTING ANY RIVET REMOVAL, THE CONTRACTOR SHALL SUBMIT AT TYPE 2
WORKING DRAWING DETAILING PROPOSED RIVET REMOVAL METHODS TO THE ENGINEER.
ACCEPTANCE WILL REQUIRE DEMONSTRATION BY THE CONTRACTOR TO ENSURE NO
DAMAGE WILL OCCUR TO THE EXISTING MEMBER TO REMAIN. NO FLAME CUTTING
METHODS WILL BE PERMITTED.
5. ALL RIVETS SHALL BE REPLACED AT L4 AND L8 GUSSET PLATES ON BOTH SIDES OF THE
TRUSS. ANY REMAINING RIVETS WHICH DO NOT MEET THE RIVET EVALUATION CRITERIA
SHALL ALSO BE REMOVED AND REPLACED WITH HIGH-STRENGTH BOLTS.
6. EXISTING RIVETS ARE ASSUMED TO BE 3/4" DIAMETER. CONTRACTOR TO FIELD-VERIFY
EXISTING RIVET DIMENSIONS AND CONTACT ENGINEER IF OTHERWISE.
RIVET INSPECTION AND REPLACEMENT NOTES:
RIVETS SHALL BE REPLACED IF THEY FAIL TO MEET ANY ONE OF THESE CRITERIA.
1. REPLACE RIVET IF THERE IS SEPARATION BETWEEN THE SOUND METAL
SURFACES OF EITHER RIVET HEAD AND THE RIVETED PARTS. (SEE SYMBOL dd )
2. REPLACE RIVET IF THE RIVET VISUALLY APPEARS TO BE LOOSE FOR ANY REASON.
RIVETS VISUALLY SUSPECT OF BEING LOOSE SHALL BE CONFIRMED LOOSE IF IT
CAN BE FELT TO MOVE AFTER BEING STRUCK ON THE SIDE OF THE HEAD IN A
DIRECTION APPROXIMATELY PERPENDICULAR TO ITS SHANK WITH A 40 OZ
HAMMER.
3. REPLACE RIVET IF SECTION LOSS IS EQUAL TO OR GREATER THAN THE DIAGRAM
SHOWN BELOW. THE ENGINEER SHALL BE CONSULTED IF UNCLEAR AS TO THE
RIVET LOADING CONDITION OR USE THE SECTION LOSS CRITERIA FOR
"UNKNOWN" LOADING CONDITION. FOR RIVETS WITH IRREGULAR SECTION LOSS,
CONTACT THE ENGINEER FOR DIRECTION.
RIVET EVALUATION CRITERIA:
RIVET INSPECTION
S6
A S8
BOTTOM CHORD
STRENGTHENING ELEVATION
SCALE: 1" = 1'-0"
BOTTOM CHORD STRENGTHENING PLAN (TOP VIEW)
SCALE: 1" = 1'-0"
EXISTING SIDE
GUSSET PLATE
SPLICE PL 12x31 2x6'-0" ±
SHIM PL 3
16 BETWEEN
EXISTING BOTTOM GUSSET
AND SPLICE PLATE, TYP
1 12"
TYP
SPLICE PLATE
EXISTING C10x15.3
BOTTOM CHORD STRENGTHENING PLAN (VIEW FROM BELOW)
SCALE: 1" = 1'-0"
EXISTING C10x15.3
EXISTING BOTTOM
GUSSET PLATE
(8) 58" BOLTS, TYP
EXISTING SIDE
GUSSET PLATE, TYP
BOLSTER PLATE
(10) 5/8" BOLTS THROUGH
SHIM AND EXISTING
BOTTOM GUSSET PL
BOLSTER
PL 12x8x13'-8"
BOLSTER
PL 12x103
4x13'-8"±
BOLSTER END PL 12x8x2'-0"
BOLSTER END PL 12x103 4x2'-0"
CL START/END
JOINT
3'-0"
31 2"
3" TYP
(8) 58" BOLTS, TYP
EXISTING SIDE
GUSSET PLATE, TYP
BOLSTER PLATE
BOLSTER PLATE
SPLICE PLATE
1 2"
BOLSTER PLATE OR
EXISTING BOLSTER
(L8B-L10B ONLY)
SPLICE PLATE
5" 5" 5" 5"
EXISTING SIDE
GUSSET PLATE, TYP
BOLSTER PLATE
SPLICE PLATE
CL INTERIOR
JOINT
SPLICE PL 12
SPLICE PL 12
CONTINUE
BOLSTER PER S2
REPLACE RIVETS WITH
HS BOLTS AT L4 AND L8
CL START/END
JOINT
CL INTERIOR
JOINT
3 4"
TY
P CONTINUE
BOLSTER PER S2
EXISTING BOTTOM
GUSSET PLATE
(8) 58" BOLTS, TYP
BOLSTER PLATE , TYP
1'-6" 1'-6" 1'-6" 1'-6"
3'-0"
B S8
3'-0"
CL START/END
JOINT
CL INTERIOR
JOINT
EXISTING SIDE
GUSSET PLATE, TYP
(8) 58" BOLTS, TYP
BOLSTER PLATE , TYP
SPLICE PL 12
3'-0"
1 12"
TYP
1 12"
TYP
3" TYP
3 4"
TY
P
1 12"
TYP
1 12"
TYP
31 2"
3" TYP
3 4"
TY
P
1 12"
TYP
5" 5" 5" 5"
1 12"
TYP
3" TYP
3 4"
TY
P
1 12"
TYP
1 2"
CONTINUE
BOLSTER PER S2
BOLSTER PLATE OR
EXISTING BOLSTER
(L8B-L10B ONLY)
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:4 0:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
7_ B o t
C h o rd
R ep ai r
D et ai ls
.d w g
08-28-2026
1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO
DRILLING BOLT HOLES IN BOLSTER PLATE.
2. PROVIDE MINIMUM (3) HANDHOLES TOP AND BOTTOM AT 3'-0" MINIMUM O.C.
IN TOP AND BOTTOM BOLSTER PLATES. SEE HANDHOLE DETAIL
CONSTRUCTION NOTES:
BOTTOM CHORD REPAIR DETAILS 1
S7
NEW 58" BOLT , TYP
NEW BOLSTER PL 12
NEW SPLICE PL 12
EXISTING C10x15.3
CL BOTTOM CHORD
CL NEW PLATE
BOTTOM CHORD
STRENGTHENING SPLICE SECTION A
S7SCALE: 3" = 1'-0"
1/4
1/4
NEW STEEL SHIM
PL 3
16x31 2x2'-0"
EXISTING C10x15.3
BOTTOM CHORD STRENGTHENING
SPLICE SECTION AT GUSSET PLATES B
S7SCALE: 3" = 1'-0"
NEW SPLICE PL 12
EXISTING BOTTOM
LATERAL GUSSET
PLATE
EXISTING SIDE
GUSSET PLATE, TYP
NEW SPLICE PL 12"
EXISTING L3x2 12x
15, TYP
HANDHOLE DETAIL C
S7SCALE: 3" = 1'-0"
8"
4"
TOP OR BOTTOM
BOLSTER PLATE
HANDHOLE, SEE
SHEET S7 NOTE 2
FOR SPACING
CL BOLSTER
CL HANDHOLE
2"
TYP
1/4
1/4
BOTTOM CHORD L6-L8 EAST - EXISTING CONDITION A
-NTS
L6-L8 EAST REPAIR PLAN
SCALE: 1" = 1'-0"
HEAT-STRAIGHTEN EXISTING
C10x15.3 WITHIN TOLERANCE
NOTED IN SPECIAL PROVISIONS
AND ENOUGH TO ALLOW FOR
STRENGTHENING WORK
3'-0" MIN 3'-0" MIN
MINIMUM HORIZONTAL EXTENTS OF MT.
SEE HEAT-STRAIGHTENING NOTE 3.
CL EXISTING BATTEN PLATE
TO BE REMOVED PRIOR TO
HEAT-STRAIGHTENING, TYP
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:4 1:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
8_ B o t
C h o rd
R ep ai r
D et ai ls
.d w g
08-28-2026
1. REMOVE PAINT ON CHANNEL SURFACES TO BE HEATED DURING HEAT-STRAIGHTENING.
SEE SPECIAL PROVISIONS FOR MORE INFORMATION. PROVIDE LOCALIZED
CONTAINMENT AS NEEDED.
2. REMOVE BATTEN PLATES.
3. MAGNETIC PARTICLE TEST CHANNEL SURFACES PRIOR TO AND AFTER
HEAT-STRAIGHTENING. SEE PLANS FOR MINIMUM HORIZONTAL EXTENTS. IF DEFECTS
ARE STILL DETECTED BEYOND THE INDICATED EXTENTS, CONTINUE TESTING UNTIL
SOUND MATERIAL IS FOUND. SUBMIT TEST REPORTS TO THE ENGINEER FOR REVIEW
AND APPROVAL.
4. HEAT-STRAIGHTEN CHANNEL IN ACCORDANCE WITH SPECIAL PROVISIONS.
HEAT-STRAIGHTENING SEQUENCING:
BOTTOM CHORD REPAIR DETAILS 2
BOTTOM CHORD L8-L10 WEST - EXISTING CONDITION B
-NTS
BOTTOM CHORD L10-L12 EAST - EXISTING CONDITION A
-NTS
L10-L12 EAST REPAIR PLAN
SCALE: 1" = 1'-0"
EXISTING BOTTOM
LATERAL GUSSET PLATE
HEAT-STRAIGHTEN EXISTING
C10x15.3 WITHIN TOLERANCE
NOTED IN SPECIAL PROVISIONS
AND ENOUGH TO ALLOW FOR
STRENGTHENING WORK
3'-0" MIN
CL EXISTING BATTEN PLATE,
(TOP AND BOTTOM) TO BE
REMOVED PRIOR TO HEAT
STRAIGHTENING, TYP
EXISTING SIDE
GUSSET PLATE
L8-L10 WEST REPAIR PLAN
SCALE: 1" = 1'-0"
HEAT-STRAIGHTEN EXISTING
C10x15.3 WITHIN TOLERANCE
NOTED IN SPECIAL PROVISIONS
AND ENOUGH TO ALLOW FOR
STRENGTHENING WORK
3'-0" MINTI
LT
O N
R
IV
E R
3'-0" MIN
EDGE OF EXISTING
SIDE GUSSET PLATE
MINIMUM HORIZONTAL EXTENTS OF MT.
SEE HEAT-STRAIGHTENING NOTE 3.
MINIMUM HORIZONTAL EXTENTS OF MT.
SEE HEAT-STRAIGHTENING NOTE 3.
CL EXISTING BATTEN PLATE,
(TOP AND BOTTOM) TO BE
REMOVED PRIOR TO HEAT
STRAIGHTENING, TYP
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:4 2:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
9_ B o t
C h o rd
R ep ai r
D et ai ls
.d w g
08-28-202613
BOTTOM CHORD REPAIR DETAILS 3
S9
1. SEE NOTES ON S8.
HEAT-STRAIGHTENING SEQUENCING:
TYPICAL LATERAL GUSSET REPAIR A
S13NTS
EXISTING BOTTOM CHORD
EXISTING 3/8" GUSSET PLATE TO BE
HEAT-STRAIGHTENED ENOUGH TO
ALLOW FOR LATERAL REPLACEMENT
ALIGN CL ANGLE WITH
CORNER OF GUSSET,
TYP BOTH SIDES NEW L3 12x2 12x
16 BRACE, TYP
EXISTING STRINGER
L3 12x2 12x
16 BRACE, TYP
TYPICAL NEW LATERAL BRACE CONNECTION B
S13NTS
CL PLATE
C L
P
LA
TE
PL 38x12x0'-9"
NS & FS
NS & FS
2" M
IN
FIELD WELD BOTH
SIDES OR BOLT USING
EXISTING HOLES, TYP
FIELD WELD BOTH
SIDES OR BOLT USING
EXISTING HOLES, TYP
LOWER LATERAL BRACING - EXISTING CONDITION 1
-NTS
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:4 5:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
_L at er al B ra ci ng R ep ai r D et ai ls .d w g
08-28-202614
LATERAL BRACING REPAIR DETAILS
S10
1. REMOVE LATERAL BRACING WITHIN ONE PANEL AT A TIME.
2. REFER TO SPECIAL PROVISIONS FOR HEAT-STRAIGHTENING REQUIREMENTS.
3. CONTRACTOR SHALL FIELD-VERIFY EXISTING CONDITIONS PRIOR TO DRILLING BOLT
HOLES IN BRACING.
NOTES:
EXISTING LACING
EXISTING C10x15.3
CL TOP CHORD
CL NEW PLATE
TOP CHORD
STRENGTHENING SECTION A
-SCALE: 3" = 1'-0"
EXISTING PL 5
BOLSTER PL
8" BOLT, TYP
3"
7'-3"
7'-3"
3"
8" BOLTS, (28) SPACES @ 6" = 14'-0"
CL EXISTING
RIVETS
EXISTING PL 5
EXISTING C10x15.3
L4-U4, L6-U6 OR L8-U8
BOLSTER
PL 12x10x14'-6"
TYPICAL TOP CHORD STRENGTHENING ELEVATION
SCALE: 1" = 1'-0"
EXISTING RIVETS 58" BOLTS BOLSTER PLEXISTING PL 5
CL EXISTING MEMBER
CL NEW PLATE
TYPICAL TOP CHORD STRENGTHENING PLAN
SCALE: 1" = 1'-0"
A
EXISTING RIVETS
VARIES
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:4 6:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
_T o p
C h o rd
R ep ai r
D et ai ls
.d w g
08-28-202615
TOP CHORD REPAIR DETAILS
S11
2" TYP
COVER
EXISTING
BACKWALL
ELEVATION: EAST END OF
NORTH ABUTMENT
SCALE: 1" = 1'-0"
A
3'-0"
2' -6
2'-0"±
4' -1
1"
EXISTING #6 @ 12"
MAX, FIELD VERIFY
EXTENT OF
CONCRETE REMOVAL
NOTES:
1. FIELD VERIFY DIMENSIONS SHOWN ABOVE
TO MATCH EXISTING WEST ABUTMENT.
NOTES:
1. FIELD VERIFY DIMENSIONS SHOWN ABOVE TO MATCH EXISTING
WEST ABUTMENT.
2. DRILL AND EPOXY NEW BARS INTO EXISTING CONCRETE TO A
MINIMUM EMBEDMENT DEPTH OF 6" USING HIT-RE 500 OR SET-3G
EPOXY OR APPROVED EQUAL.
3. VERTICAL SAW CUT 1/2" DEEP AND 1" BEYOND DAMAGED CONCRETE.
EXISTING DAMAGED
WINGWALL TO BE
REMOVED AND
REPLACED AS SHOWN
#6@12" MAX BOTH WAYS,
SPLICE WITH EXISTING
HORIZONTAL BARS,
SEE NOTE 2
2" T
YP
C
O
VE
R
DAMAGED WINGWALL SECTION A
-SCALE: 1" = 1'-0"
8"±
WINGWALL EXISTING CONDITION
SCALE: NTS
DRILL AND EPOXY NEW
BARS INTO EXISTING
CONCRETE, SEE NOTE 2
6" MIN
TYP
CUT EXISTING REBAR AT
CONCRETE SURFACE
SAW CUT 1/2" DEEP AND
SAND BLAST EXISTING
CONCRETE TO CREATE A
CLEAN, SOUND SURFACE
PER 5-01.3(5) PRIOR TO
CASTING NEW CONCRETE
VARIES
(SEE NOTE 3)
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:4 7:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
_A b ut
R ep ai r
D et ai ls
.d w g
08-28-202616
ABUTMENT REPAIR DETAILS
S12
8"
STRINGER SPLICE DETAIL 2
-SCALE: 1 1/2"=1'-0"
HMA OVERLAY
DECK PLANK
3/4" THROUGH-BOLT,
(1) PER SPLICE
2x6 TIMBER SHIM
CENTERED ON
FLOOR BEAM
3/4"x 8" COUNTERSUNK
LAG BOLTS, 1 PER
DECK PLANK
BULL RAIL ATTACHMENT ELEVATION 3
-SCALE: 1 1/2"=1'-0"
4'-0" MAX O.C.
4x6x6" TIMBER BULL
RAIL SUPPORT
3/4"x12" LAG BOLT
CENTERED ON
SUPPORT, TYP
DECK PLANK, TYP
TIMBER BULL RAIL
3/4" THROUGH-BOLT,
(2) PER SPLICE,
OFFSET 1' FROM CL
FLOOR BEAM EACH
DIRECTION
EXTERIOR
STRINGER
SPLICE
40D NAIL, TYP BOTH SIDES,
CENTERED ON FLOOR BEAM
WATERPROOF
MEMBRANE
TIMBER BRACE ATTACHMENT DETAIL 4
-SCALE: 1 1/2"=1'-0"
NEW 2x6 TIMBER BRACE
3/4"x6" LAG BOLTS,
(1) PER STRINGER,
CENTERED ON BRACE
AND STRINGER
TIMBER BULL RAIL
EXTERIOR TIMBER
STRINGER
TIMBER BULL RAIL
SUPPORT
INTERIOR TIMBER
STRINGERS
EXISTING STEEL
FLOOR BEAM
4x6 TIMBER BULL
RAIL SUPPORT, TYP
2 12" HMA OVERLAY TO
MATCH EXISTING
(15) 6x16 TIMBER
STRINGERS
(SEE NOTE 2)
TYPICAL DECK REPLACEMENT DETAILS 1
-SCALE: 1/2" = 1'-0"
17'-0" MIN
4x12 DECK PLANKS
4x6 TIMBER
BULL RAIL, TYP
2x6 TIMBER SHIM
WATERPROOF
MEMBRANE
18'-0"
1'-9" MAX
1'-3" MAX UNO
'-4
C
L
C L
TR
U
S S
E Q
(1 5)
T
IM
B E
R S
TR
IN
G E
R S
P E
R P
A N
E L
EXISTING FLOOR BEAM
STEEL CROSS BRACE, TYP
REPLACEMENT BELOW DECK FRAMING PLAN
8'4'2'0
1/4 inch = 1 foot
12' (48)
B4"
TYP
A 2x6 TIMBER BRACE
3'-0"
TYP
S10
S10
6x16 EXTERIOR
STRINGER SPLICE, TYP
PANEL 1 PANEL 2 PANEL 3 PANEL 4 PANEL 5 PANEL 6
E Q
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:4 8:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
_D ec k
R ep la ce m en t D et ai ls .d w g
08-28-202617
NOTES:
1. TIMBER STRINGERS, DECK, AND BULL RAIL TO BE DOUGLAS FIR
GRADE NO. 1 OR BETTER.
2. STAGGER STRINGERS AT FLOOR BEAMS WHERE SPLICES ARE
REQUIRED. TYPICAL REPLACEMENT STRINGER SPACING IS 1'-3"
ON CENTER. LIMIT STRINGER SPACING TO 1'-9" ON CENTER AT
EXTERIOR STRINGERS.
3. ALL TIMBER TO BE TREATED WITH AZCA PER AWPA STANDARDS
WITH USE CATEGORY OF UC4A.
DECK REPLACEMENT DETAILS
S13
EXISTING TIMBER STRINGER
TO BE REMOVED
EXISTING TIMBER DECK
PLANKS TO BE REMOVED
EXISTING CONCRETE
ABUTMENT TO REMAIN
EXISTING EXPANSION JOINT
ASSEMBLY TO BE REMOVED
EXISTING EXPANSION JOINT DETAILS 1
-NTS
CLEAN AS NEEDED
TO FACILITATE
PLACEMENT OF
NEW JOINT
6"
3"
21 4"
1"
6"
3" 2"
1 1
2 "
EXISTING CONCRETE
ABUTMENT AND STEEL
ANGLE TO REMAIN
PL 34x10
3/4"x 3"
COUNTERSUNK
LAG SCREW
CUT 6" WIDE GROOVE IN TOP OF
DECK PLANK SUCH THAT TOP OF
DECK PLANK IS FLUSH WITH
BOTTOM OF STEEL ANGLE LEG
NEW TIMBER
DECK PLANK
NEW TIMBER
STRINGER
CUT 4" WIDE GROOVE
IN TOP OF STRINGERS
SUCH THAT TOP OF
PLATE IS FLUSH WITH
TOP OF STRINGERS
4" BOLT, TYP
CL
PLA
TE
CL
HOLE
CL SCREW
EXPANSION JOINT
REPLACEMENT DETAIL 2
-NTS
SILICONE JOINT SEALANT
BACKER ROD
PL 12x5
STRINGER
CONNECTION PL 12
1/4 1/4
EXPANSION JOINT -
EXISTING CONDITION 3
-(SOUTH END)
45°
HMA OVERLAY
PL 12x4
PL 12x5
1/4
EXPANSION JOINT -
EXISTING CONDITION 4
-(NORTH END)
EXISTING HMA
OVERLAY WATERPROOF
MEMBRANE
AT SOUTH END, SAWCUT AT PLATE EDGE.
AT NORTH END, SAWCUT 1'-0" BEYOND
EDGE OF CONCRETE. TAPER NEW HMA
OVERLAY AS REQUIRED TO MATCH
SAWCUT 1 INCH BUTT JOINT
AND SEAL PER WSDOT
STANDARD PLAN A-40.20-04
PL 12x5
18'-1"
PL 34x10 COUNTERSUNK HOLES FOR
LAG SCREWS, TYP
STRINGER
CONNECTION
PL 12, TYP
EXPANSION JOINT REPLACEMENT PLAN 5
-SCALE: 1"=1'-0"
10 SPA AT 1'-21
2" = 12'-1"
TIMBER
STRINGER, TYP
3 SPA AT 1'-3" = 3'-9" 2'-21
2"
3"
TYP
2" 31
2"
57 W. MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
FAX # (360) 740-2719
DESIGNED BY : AGC
DRAWN BY : TLP
CHECKED BY : AJG
DATE : 09-02-2026
NO. DATE BY APP.
COUNTY ROAD PROJECT NO: 2198DAVISON RD MP 0.01
BRIDGE REHABILITATION
REVISION
OF "It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center18 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.comN am e:
k yl e.
h ar ve y D at e:
A ug
1, 6-
:4 9:
p m F ile : V
(D av is o n
R d
B ri d g e R eh ab
_D es ig n
(v
D R
B -S
_E xp J t R ep la ce m en t
D et ai ls
.d w g
08-28-202618
EXPANSION JOINT REPLACEMENT DETAILS
S14
| DRB-G1_Cover Sheet-Layout1 |
| DRB-G2_Legend & Quantities-Layout1 |
| DRB-C1_MOT Plan 1 |
| DRB-C2_MOT Plan 2 |
| DRB-S1_Plan and Elevation-Layout1 |
| DRB-S2_Truss Repair Elevation-Layout1 |
| DRB-S3_Truss Repair Plan-Layout1 |
| DRB-S4_Typical Section-Layout1 |
| DRB-S5_Construction Sequence-Layout1 |
| DRB-S6_Rivet Inspection-Layout1 |
| DRB-S7_Bot Chord Repair Details 1-Layout1 |
| DRB-S8_Bot Chord Repair Details 2-Layout1 |
| DRB-S9_Bot Chord Repair Details 3-Layout1 |
| DRB-S10_Lateral Bracing Repair Details-Layout1 |
| DRB-S11_Top Chord Repair Details-Layout1 |
| DRB-S12_Abut Repair Details-Layout1 |
| DRB-S13_Deck Replacement Details-Layout1 |
| DRB-S14_Exp Jt Replacement Details-Layout1 |
File details come from the government source that posted it. Updated .