0172-0544 TRC Investigation Report Groton Maintenance Salt Shed June 2026.pdf
PDF 4 MB Posted
- Solicitation number
- 0172-0544
- Issued by
- New London County, Connecticut
About this file
This is a pre-demolition investigative survey report prepared by TRC for the Connecticut Department of Transportation regarding hazardous building materials at the Groton Maintenance Facility Salt Shed located at 150 Welles Road, Groton, Connecticut (Project No. 172-544). The survey was conducted on May 22, 2026 and June 4, 2026 by licensed asbestos inspectors Andrew Smith (License #1137) and Tyler Noll (License #1053), with lead paint inspections performed by Andrew Smith (License #2316) and Alexa Knight. The facility has no historic significance designation. The investigation focused on identifying asbestos-containing materials, lead paint, and other hazardous building materials present at the salt shed facility prior to any demolition activities. The report includes comprehensive sampling and analysis across multiple tables documenting bulk samples of suspect materials, identified and confirmed non-asbestos-containing materials, lead paint XRF measurements, and composite building material waste characterization.
The survey findings indicate that no asbestos-containing materials were identified in the subject area, and lead paint testing results were all below one percent thresholds. The report documents general building material hazardous waste present at the facility and provides detailed laboratory analysis data, site photographs, site sketches, inspector certifications, and laboratory accreditations as supporting documentation. The investigation was conducted under TRC Project No. 501871.8360.0710, with the Connecticut Department of Transportation project manager Benjamin Silverman overseeing the assignment. The report was issued in June 2026 and includes inventory of additional hazardous and regulated materials identified during the site inspection.
View the file
Other files
Show 40 more
Latest 50 of 87 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SURVEY REPORT
PRE-DEMOLITION
INVESTIGATIVE SURVEY FOR HAZARDOUS
BUILDING MATERIALS
GROTON MAINTENANCE FACILITY
SALT SHED
150 WELLES ROAD
GROTON, CONNECTICUT
Project No.172-544
Prepared for
State of Connecticut Department of Transportation
Newington, Connecticut
Prepared by
TRC
Windsor, Connecticut
Issued
June 2026
PRE-DEMOLITION
INVESTIGATIVE SURVEY FOR
HAZARDOUS BUILDING MATERIALS
GROTON MAINTENANCE FACILITY
SALT SHED
150 WELLES ROAD
GROTON, CONNECTICUT
Project No.172-544
Prepared for
Department of Transportation Newington, Connecticut
Prepared by
TRC
Windsor, Connecticut
Stephen R. Arienti, CHMM SIH New England Regional Area Leader – Engineer in Charge
Erik R. Plimpton, P.E., CHMM, CMC Vice President SIH – Engineer in Charge
TRC Project No. 501871.8360.0710
Issued-June 2026
TRC
21 Griffin Road North Windsor, Connecticut 06095 Telephone (860) 298-9692
TABLE OF CONTENTS
PROJECT OUTLINE
TABLES
1 BULK SAMPLE SUMMARY OF SUSPECT ASBESTOS CONTAINING
MATERIALS
2 IDENTIFIED ASBESTOS CONTAINING MATERIALS
3 CONFIRMED NON-ASBESTOS CONTAINING MATERIALS
4 SUMMARY OF LEAD PAINT XRF MEASUREMENTS
5 SUMMARY OF COMPOSITE BUILDING MATERIAL WASTE CHARACTERIZATION
6 INVENTORY OF ADDITIONAL HAZARDOUS/REGULATED MATERIALS, WASTES
AND ITEMS IDENTIFIED
APPENDICES
A SITE PHOTOS
B SITE SKETCH
C CONNECTICUT STATE HISTORICAL PRESERVATION OFFICE SITE REVIEW
D TRC INSPECTORS LICENSES/CERTIFICATIONS
E LABORATORY ACCREDITATIONS
F ASBESTOS PLM LABORATORY ANALYSIS DATA
G ASBESTOS TEM LABORATORY ANALYSIS DATA
H LEAD PAINT XRF MEASUREMENT TABLE
I CTDEEP/EPA MEMO OF JANUARY 26, 2004
J RELATED CORRESPONDENCE
PROJECT OUTLINE
DOT Project No.:
Assignment No.:
DOT Project Manager:
Site Address:
TRC Project No.:
Asbestos Inspector(s):
Lead Inspector:
Date(s) of Inspection:
Historic Significance:
Asbestos Identified:
Lead Paint Identified:
Gen. Bldg. Mat. Haz Waste:
172-544
524-8360
Benjamin Silverman
150 Welles Road Groton, Connecticut 06355
501871.8360.0710
Andrew Smith (LIC #1137) Tyler Noll (LIC #1053) Alexa Knight
Andrew Smith (LIC #2316)/Alexa Knight
May 22, 2026 & June 4, 2026
None
None
Yes, however all XRF readings tested <1.0 mg/cm2
No, per EPA/CTDEEP memo dated January 26, 2004
Add’l Haz./Reg. Mat./Waste/Items: Yes (See Table 6)
Additional Notes:
The salt shed building is located at the Groton Maintenance Facility, 150 Welles Road in Groton, Connecticut. The building is scheduled for future demolition as part of site-wide renovations.
TABLES
ND Asbestos was not detected Trace Asbestos was observed at a level of 1% or less NA/PS Not Analyzed/Positive Stop + Although found to be negative by analysis, material is homogeneous to a determined ACM and therefore must be considered positive 1 NOB Result confirmed by TEM analyses
* Quantified by EPA 400 Point Count Method
TABLE 1
BULK SAMPLE SUMMARY OF SUSPECT ASBESTOS CONTAINING MATERIALS
GROTON MF SALT SHED
150 WELLES ROAD
GROTON, CONNECTICUT
Sample No. Sample Location Type of Homogeneous Material % and Type Asbestos
1 A side electrical panel conduit EP 1 - Black electrical puddy on conduit penetrations
ND1
2 A side electrical panel conduit EP 1 - Black electrical puddy on conduit penetrations
ND
3 A side interior VB1 - Black vapor barrier behind interior plywood panels
ND1
4 B side interior VB1 - Black vapor barrier behind interior plywood panels
ND
5 B side exterior C1 - Grey exterior caulk ND1
6 D side exterior C1 - Grey exterior caulk ND
7 C side exterior C2 - Red louvre caulk ND1
8 C side exterior C2 - Red louvre caulk ND
9 C side exterior VB2 - Black vapor barrier under exterior shakes
ND1
10 B side exterior VB2 - Black vapor barrier under exterior shakes
ND
11 B side interior C3 - Black support beam base caulk ND1
12 D side interior C3 - Black support beam base caulk ND
13 D side roof RS1 - Grey rubber roof membrane sealant
ND1
14 B side roof RS1 - Grey rubber roof membrane sealant
ND
15 D side roof G1 - Yellow rubber membrane glue on gypsum roof boards
ND1
16 B side roof G1 - Yellow rubber membrane glue on gypsum roof boards
ND
17 D side roof SHR1 - Grey gypsum roof board ND
18 B side roof SHR1 - Grey gypsum roof board ND
19 D side roof VB3 - Blue vapor barrier paper between gypsum roof board and plywood roof deck
ND1
20 B side roof VB3 - Blue vapor barrier paper between gypsum roof board and plywood roof deck
ND
ND Asbestos was not detected Trace Asbestos was observed at a level of 1% or less NA/PS Not Analyzed/Positive Stop + Although found to be negative by analysis, material is homogeneous to a determined ACM and therefore must be considered positive 1 NOB Result confirmed by TEM analyses
* Quantified by EPA 400 Point Count Method
TABLE 1
BULK SAMPLE SUMMARY OF SUSPECT ASBESTOS CONTAINING MATERIALS
GROTON MF SALT SHED
150 WELLES ROAD
GROTON, CONNECTICUT
Sample No. Sample Location Type of Homogeneous Material % and Type Asbestos
21 D side roof IN1 - White roof insulation under rubber room membrane
ND
22 B side roof IN1 - White roof insulation under rubber room membrane
ND
AHERA Categories = thermal system insulation (TSI), surfacing material or miscellaneous NESHAP Categories = friable, category I non-friable or category II non-friable Friable = crumbled, pulverized or reduced to powder by hand pressure when dry Category I Non-friable = packings, gaskets, resilient floor covering and asphalt roofing Category II Non-friable = all non-friable that is not Category I
TABLE 2
IDENTIFIED ASBESTOS CONTAINING MATERIALS (>1%)
GROTON MF SALT SHED
150 WELLES ROAD
GROTON, CONNECTICUT
Material Sampled/ Assumed (mo/yr)
General Location NESHAP Category
AHERA
Category
Estimated Quantity
No asbestos-containing materials were identified in the subject area.
TABLE 3
CONFIRMED NON-ASBESTOS CONTAINING MATERIALS (<1%)
GROTON MF SALT SHED
150 WELLES ROAD
GROTON, CONNECTICUT
Material General Location
EP1 - Black electrical puddy on conduit penetrations A side electrical panel conduit VB1 - Black vapor barrier behind interior plywood panels Behind plywood panels on interior
C1 - Grey exterior caulk B & D side exterior C2 - Red louvre caulk C side exterior VB2 - Black vapor barrier under exterior shakes Under exterior shakes C3 - Black support beam base caulk Interior around base of beam supports RS1 - Grey rubber roof membrane sealant Roof G1 - Yellow rubber membrane glue on gypsum roof boards On gypsum roof boards
SHR1 - Grey gypsum roof board Roof VB3 - Blue vapor barrier paper between gypsum roof board and plywood roof deck Between gypsum roof board and plywood roof deck
IN1 - White roof insulation under rubber roof membrane Under rubber roof membrane
TABLE 4
SUMMARY OF LEAD PAINT XRF MEASUREMENTS
GROTON MF SALT SHED
150 WELLES ROAD
GROTON, CONNECTICUT
Structure No. of Measurements Calibrations Void Lead
Detected No Lead Detected
Groton MF Salt Shed 30 7 3 3 17
See Lead Paint XRF Measurement Table in Appendix H.
TABLE 5
SUMMARY OF COMPOSITE BUILDING MATERIAL WASTE CHARACTERIZATION
GROTON MF SALT SHED
150 WELLES ROAD
GROTON, CONNECTICUT
Waste Stream Metal mg/L Leachate Hazardous/Non-Hazardous
Salt Shed Bldg. Material
Composite (Excluding metal substrates and clean concrete/brick)
No TCLP sample for Lead warranted as XRF readings on non-metallic components were all below 1.0 mg/cm2 and therefore the debris is presumed as non-hazardous per
CTDEEP/USEPA clarification memo of January 26, 2004.
Note: Any metal components should be recycled to promote waste minimization efforts, rather than disposed of, and the recycling operation is exempt from the USEPA RCRA and CTDEEP Hazardous Waste regulations.
See Appendix I for CTDEEP/USEPA clarification memo of January 26, 2004.
CRW- Connecticut Regulated Waste – PCBs (CR01), Oils (CR02/CR03), waste chemical liquids - antifreeze, latex & solvent paints, sludges, etc. (CR04), waste chemical solids (CR05)
UW- Universal Waste (batteries, thermostat ampoules, fluorescent lamps, used electronics) IH- Inhalation hazard (silicas, etc.)
I- Ignitable - may contain ingredients which are ignitable (materials which have a flashpoint <140oF) (D001) C- Corrosive - may contain ingredients which are alkaline or acidic (materials with a PH<2 or >12.5) (D002) T- Toxic - may contain ingredients which are harmful if swallowed or which release vapors that can cause irritation R- Reactive – may contain ingredients which are unstable, react violently with water or are explosive (D003)
TABLE 6
INVENTORY OF ADDITIONAL HAZARDOUS/REGULATED
MATERIALS, WASTES AND ITEMS IDENTIFIED
GROTON MF SALT SHED
150 WELLES ROAD
GROTON, CONNECTICUT
Quantity Size Material/Item General Location Potential Hazard
1 Motion Sensors/Heat Sensors Salt shed UW - Circuit boards 1 Magnesium chloride tank Salt shed CRW - Waste Chemical Liquid
APPENDIX A
SITE PHOTOS
CTDOT
Groton MF Salt Shed
TRC# 501871-8360-0710
PHOTO 1
Salt Shed Exterior
PHOTO 2
PHOTO 3
PHOTO 4
Salt Shed Interior
PHOTO 5
Salt Shed Interior
PHOTO 6
Salt Shed Roof
APPENDIX B
SITE SKETCH
APPENDIX C
CONNECTICUT STATE HISTORICAL
PRESERVATION OFFICE SITE REVIEW
APPENDIX D
TRC INSPECTORS LICENSES/CERTIFICATIONS
Lookup Detail View Name
Name
ANDREW J SMITH
License Information lookup
License Type License Number
Expiration Date
Granted Date
License Name
License Status
Licensure Actions or Pending Charges
Asbestos Consultant- Inspector
1137 08/31/2026 11/22/2022 ANDREW
J SMITH
ACTIVE CURRENT None
Generated on: 12/19/2025 12:46:10 PM
12/19/25, 12:46 PM Print Lookup Details https://www.elicense.ct.gov/Lookup/PrintLicenseDetails.aspx?cred=2425922&contact=2746664 1/1
Lookup Detail View Name
TYLER J NOLL
License Information lookup
6/8/2026 10:05:20 AM
License Type Asbestos Consultant-Inspector
License Number
Expiration Date 05/31/2027
Granted Date 10/18/2019
License Name
TYLER J NOLL
License Status
ACTIVE
CURRENT
Licensure Actions or Pending Charges None
APPENDIX E
LABORATORY ACCREDITATIONS
State of Connecticut, Department of Public Health Approved Environmental Laboratory
THIS IS TO CERTIFY THAT THE LABORATORY DESCRIBED BELOW HAS BEEN APPROVED BY THE STATE DEPARTMENT OF PUBLIC HEALTH PURSUANT TO APPLICABLE PROVISIONS OF THE PUBLIC HEALTH CODE AND GENERAL STATUTES OF CONNECTICUT, FOR MAKING THE EXAMINATIONS, DETERMINATIONS OR TESTS SPECIFIED BELOW WHICH HAVE BEEN AUTHORIZED IN WRITING BY THAT DEPARTMENT.
TRC ENVIRONMENTAL CORPORATION
LOCATED AT 21 Griffin Road North IN Windsor, CT 06095 AND REGISTERED IN THE NAME OF Stephen Arienti THIS CERTIFICATE IS ISSUED IN THE NAME OF Kathleen Williamson WHO HAS BEEN DESIGNATED BY THE REGISTERED OWNER/AUTHORIZED AGENT TO BE IN CHARGE OF THE LABORATORY WORK COVERED BY THIS CERTIFICATE OF
APPROVAL AS FOLLOWS:
Examination For:
ASBESTOS FIBERS – PCM
ASBESTOS IN BULK – PLM
SEE CERTIFIED PARAMETER LIST FOR SPECIFIC TESTS APPROVED
EFFECTIVE RENEWAL DATE April 1, 2026 THIS CERTIFICATE EXPIRES March 31, 2028 AND IS REVOCABLE FOR CAUSE BY THE STATE DEPARTMENT OF PUBLIC HEALTH
DATED AT HARTFORD, CONNECTICUT, THIS 4th DAY OF March, 2026
Registration No.
PH–0426 Lisa Michelle Morrissey, MPH Deputy Commissioner
Rev. Feb. 2023
STATE OF CONNECTICUT
DEPARTMENT OF PUBLIC HEALTH
ENVIRONMENTAL LAB CERTIFICATION PROGRAM
(ELCP)
CERTIFIED ANALYTES REPORT FOR ALL MATRICES
TRC-Environmental Corporation
PH-0426
21 GRIFFIN ROAD NORTH
ANY QUESTIONS CONCERNING THIS DOCUMENT SHOULD BE ADDRESSED TO THE
ENVIRONMENTAL LABORATORY CERTIFICATION PROGRAM AT (860) 509-7389
REVIEWED BY 2/13/2026 9:46:46 AM
LABORATORY REGISTRATION EXPIRATION DATE :
LABORATORY STATUS :
03/31/2028
APPROVED
WINDSOR, CT 06095
Dawn Shaban
PHONE :
REGISTERED OWNER / AUTHORIZED AGENT :
DIRECTOR :
CO DIRECTOR(S) :
(860) 298-6308
Stephen Arienti
Kathleen Williamson
LABORATORY REGISTRATION EFFECTIVE DATE : 04/01/2026
CT REGISTRATION NUMBER :
APPROVED BY
Lisa Michelle Morrissey, MPH Deputy Commissioner
Connecticut Department of Public Health
Laboratory Consultant
Report Printed on: 2/13/2026 9:46:46 AM Page 1 of 4 TRC-Environmental Corporation
3/4/2026
AIR
STATUS REPORTED ON 2/13/2026
ANALYTE NAME
ASBESTOS
Asbestos Fibers (PCM) NIOSH 7400
Report Printed on: 2/13/2026 9:46:46 AM Page 2 of 4
CONSTRUCTION, RENOVATION & DEMO BLDG
MATERIALS
STATUS REPORTED ON 2/13/2026
ANALYTE NAME
ASBESTOS
Asbestos in Bulk Materials (PLM) 40 CFR Part 763, Subpart E, Appendix E Asbestos in Bulk Materials (PLM) EPA-600-R-93-116
Report Printed on: 2/13/2026 9:46:46 AM Page 3 of 4
THIS IS THE LAST PAGE OF THE REPORT
Report Profile: Lab Name : TRC-Environmental Corporation
Test Name : *
Matrix Name : *
Matrix Selection = ALL OR SOME MATRICES SELECTED
Certifications approved or provisional on 2/13/2026
Report Printed on: 2/13/2026 9:46:46 AM Page 4 of 4
United States Department of Commerce National Institute of Standards and Technology
Certificate of Accreditation to ISO/IEC 17025:2017
NVLAP LAB CODE: 101424-0
TRC Environmental Corporation Windsor, CT is accredited by the National Voluntary Laboratory Accreditation Program for specific services, listed on the Scope of Accreditation, for:
Asbestos Fiber Analysis
2025-07-01 through 2026-06-30 Effective Dates For the National Voluntary Laboratory Accreditation Program
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communique on ISO/IEC 17025).
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
For the National Voluntary Laboratory Accreditation Program
Effective
National Voluntary Laboratory Accreditation Program
2025-07-01 through 2026-06-30
TRC Environmental Corporation 21 Griffin Road North Windsor, CT 06095
Ms. Kathleen Williamson Phone: 860-298-6392 Fax: 860-298-6214
Email: kwilliamson@trccompanies.com www.trccompanies.com/
ASBESTOS FIBER ANALYSIS NVLAP LAB CODE 101424-0
Bulk Asbestos Analysis
Code Description 18/A01 EPA -- 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of
Asbestos in Bulk Insulation Samples
18/A03 EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials
State of Connecticut, Department of Public Health Approved Environmental Laboratory
THIS IS TO CERTIFY THAT THE LABORATORY DESCRIBED BELOW HAS BEEN APPROVED BY THE STATE DEPARTMENT OF PUBLIC HEALTH PURSUANT TO APPLICABLE PROVISIONS OF THE PUBLIC HEALTH CODE AND GENERAL STATUTES OF CONNECTICUT, FOR MAKING THE EXAMINATIONS, DETERMINATIONS OR TESTS SPECIFIED BELOW WHICH HAVE BEEN AUTHORIZED IN WRITING BY THAT DEPARTMENT.
EMSL ANALYTICAL, INC. – CARLE PLACE
LOCATED AT 528 Mineola Avenue IN Carle Place, NY 11514
AND REGISTERED IN THE NAME OF Nicholas Straccione
THIS CERTIFICATE IS ISSUED IN THE NAME OF Daniel Clarke WHO HAS BEEN DESIGNATED BY THE REGISTERED OWNER/AUTHORIZED AGENT TO BE IN CHARGE OF THE LABORATORY WORK COVERED BY THIS CERTIFICATE OF
APPROVAL AS FOLLOWS:
DRINKING WATER, NON-POTABLE WATER/
ASBESTOS
ENVIRONMENTAL HEALTH & HOUSING
WASTEWATER
Examination For:
BACTERIA & LEGIONELLA
LEAD
Examination For:
FIBERS – PCM, TEM
BULK – PLM, TEM
DRINKING WATER - TEM
Examination For:
LEAD IN PAINT CHIPS
LEAD IN DUST WIPES
LEAD IN SOIL
SEE CERTIFIED PARAMETER LIST FOR SPECIFIC TESTS APPROVED
EFFECTIVE RENEWAL DATE April 1, 2025
THIS CERTIFICATE EXPIRES March 31, 2027
AND IS REVOCABLE FOR CAUSE BT THE STATE DEPT OF PUBLIC HEALTH
DATED AT HARTFORD, CONNECTICUT, THIS 26th DAY OF February, 2025
Registration
PH–0249
Lisa Michelle Morrissey, MPH Deputy Commissioner
REV. FEB 2023
STATE OF CONNECTICUT
DEPARTMENT OF PUBLIC HEALTH
ENVIRONMENT LAB CERTIFICATION PROGRAM (ELCP)
CERTIFIED ANALYTES REPORT FOR ALL MATRICES
EMSL Analytical, Inc.-Carle Place
PH-0249
528 MINEOLA AVE.
ANY QUESTIONS CONCERNING THIS DOCUMENT SHOULD BE ADDRESSED TO THE
ENVIRONMENTAL LABORATORY CERTIFICATION PROGRAM AT (860) 509-7389
REVIEWED BY 2/26/2025 2:07:43 PM
LABORATORY REGISTRATION EXPIRATION DATE :
LABORATORY STATUS :
03/31/2027
APPROVED
CARLE PLACE, NY 11514
Mike Mitchell
PHONE :
REGISTERED OWNER / AUTHORIZED AGENT :
DIRECTOR :
CO DIRECTOR(S) :
(516) 997-7251
Nicholas Straccione
Daniel Clarke
LABORATORY REGISTRATION EFFECTIVE DATE : 04/01/2025
CT REGISTRATION NUMBER :
APPROVED BY
Lisa Michelle Morrissey, MPH Deputy Commissioner
Connecticut Department of Public Health
Laboratory Consultant
Report Printed on: 2/26/2025 2:07:43 PM Page 1 of 6 EMSL Analytical, Inc.-Carle Place
AIR
STATUS REPORTED ON 2/26/2025
ANALYTE NAME
ASBESTOS
ASBESTOS FIBERS (PCM) NIOSH 7400 ASBESTOS FIBERS (TEM) 40 CFR Part 763, Subpart E, Appendix A
Report Printed on: 2/26/2025 2:07:44 PM Page 2 of 6
CONSTRUCTION, RENOVATION & DEMO BLDG
MATERIALS
STATUS REPORTED ON 2/26/2025
ANALYTE NAME
ASBESTOS
ASBESTOS IN BULK MATERIALS (PLM) EPA-600-R-
93-116
ASBESTOS IN BULK MATERIALS (TEM) EPA-600-R-
93-116
Report Printed on: 2/26/2025 2:07:44 PM Page 3 of 6
DRINKING WATER (SDWA)
ANALYTE NAME
MICROBIOLOGY/BACTERIA
Heterotrophic plate count SM9215B Legionella CDC ELITE
METALS
Lead EPA 200.8
ASBESTOS
ASBESTOS IN WATER (TEM) EPA 100.2
Report Printed on: 2/26/2025 2:07:44 PM Page 4 of 6
NON-POTABLE WATER/ WASTEWATER (CWA)
ANALYTE NAME
MICROBIOLOGY/BACTERIA
Heterotrophic plate count SM9215B Legionella CDC ELITE
Report Printed on: 2/26/2025 2:07:44 PM Page 5 of 6
THIS IS THE LAST PAGE OF THE REPORT
Report Profile: Lab Name : EMSL Analytical, Inc.-Carle Place
Test Name : *
Matrix Name : *
Matrix Selection = ALL OR SOME MATRICES SELECTED
Certifications approved or provisional on 2/26/2025
Report Printed on: 2/26/2025 2:07:44 PM Page 6 of 6
United States Department of Commerce National Institute of Standards and Technology
Certificate of Accreditation to ISO/IEC 17025:2017 is accredited by the National Voluntary Laboratory Accreditation Program for specific services, listed on the Scope of Accreditation, for:
Effective Dates For the National Voluntary Laboratory Accreditation Program
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communique on ISO/IEC 17025).
APPENDIX F
ASBESTOS PLM LABORATORY ANALYSIS DATA
Industrial Hygiene Laboratory 21 Griffin Road North Windsor, CT 06095
(860) 298-6308
69664.CT-DOT.doc
Lab Log #: 0069664
Maintenance Facility Salt Shed, 150 Welles Road, Groton, CT
CLIENT: CT Department of Transportation
Site:
Date Analyzed:
Date Received:
05/26/2026
05/22/2026
Project #: 501871.8360.0710
BULK ASBESTOS ANALYSIS REPORT
Asbestos Type
Other Matrix MaterialsSample No.
Asbestos
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
Sample Location Homogeneous
Material Description
A side electrical panel conduits - - - None1 NDBlack EP 1 - electrical puddy on conduit penetrations
A side electrical panel conduits - - - None2 NDBlack EP 1 - electrical puddy on conduit penetrations
A side interior - - - None3 NDBlack VB1 - vapor barrier behind interior plywood panels
B side interior - - - None4 NDBlack VB1 - vapor barrier behind interior plywood panels
B side exterior - - - None5 NDGrey C1 - exterior caulk
D side exterior - - - None6 NDGrey C1 - exterior caulk
C side exterior - - - None7 NDRed C2 - louvre caulk
C side exterior - - - None8 NDRed C2 - louvre caulk
C side exterior cellulose None9 ND80%Black VB2 - vapor barrier under exterior shakes
B side exterior cellulose None10 ND80%Black VB2 - vapor barrier under exterior shakes
B side interior - - - None11 NDBlack C3 - support beam base caulk
D side interior - - - None12 NDBlack C3 - support beam base caulk
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0
RI #PLM00007 TX #300354
CO# AL-21772
AIHA LAP #100122
VT #An-000020
LA#05011
CT #PH-0426
VA #3333 000283
PA#68-03387
NY #10980
NV #CT00004
WA #C1071
WV #000622
CA #2907
ME LB-0071
AZ #AZ0944
PHIL#ALL-461
MA #AA000052
HI #L-09-004
21 Griffin Road North Windsor, CT 06095
(860) 298-6308
69664.CT-DOT.doc
Asbestos Type
Other Matrix MaterialsSample No.
Asbestos
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
Sample Location Homogeneous
Material Description
Trace - asbestos was observed at level of 1% or less - This is the reporting limit NA/PS - Not Analyzed / Positive Stop SNA - Sample Not Analyzed- See Chain of Custody for details Notes: Asbestos-Containing Material (ACM) is any material containing more than 1% asbestos
The Laboratory at TRC follows 18/01A EPA -- 40 CFR Appendix E to subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples and 18/A03 EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials which utilize polarized light microscopy (PLM). Our analysts have completed an accredited course in asbestos identification. TRC's Laboratory is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), for Bulk Asbestos Fiber Analysis, NVLAP Code 101424-01. TRC is accredited by the AIHA Laboratory Accreditation Programs AIHA LAP (ID: LAP-100122) in the Industrial Hygiene Program (IHLAP) for PLM. Asbestos content is determined by visual estimate unless otherwise indicated. Quality Control is performed in-house on at least 10% of samples and QC data related to the samples is available upon written request from client.
This report shall not be reproduced, except in full, without the written approval of TRC. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report relates only to the items tested, as received by the laboratory.
ND - asbestos was not detected
Note: Polarized-light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. In those cases, EPA recommends, and certain states (e.g. NY) require, that negative results be confirmed by quantitative transmission electron microscopy.
Analyzed by: Reviewed by Date Issued
05/26/2026Najaat Bhura, Approved SignatoryKathleen Williamson, Laboratory Manager
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0
RI #PLM00007 TX #300354
CO# AL-21772
AIHA LAP #100122
VT #An-000020
LA#05011
CT #PH-0426
VA #3333 000283
PA#68-03387
NY #10980
NV #CT00004
WA #C1071
WV #000622
CA #2907
ME LB-0071
AZ #AZ0944
PHIL#ALL-461
EMSL
528 Mineola Ave, Carle Place, NY 11514 TEM Bulk Chain of Custody Record
Date: 05/26/2026
PO#: C501871 Analysis Type: TEM EPA N.O.B Client: CT DOT Client Job#: 501871.8360.0710 Client Job Ref./Loc. Maintenance Salt Shed, Groton, CT Relinquished by: K. Williamson Received by:
Report to: KWilliamson@trccompanies.com; SArienti@trccompanies.com EPlimpton@trccompanies.com
DCarillo@trccompanies.com KGraff@trccompanies.com NBhura@trccompanies.com GKaczynski@trccompanies.com Sampler’s Name: A. Smith
Turnaround Time: <12 Hour <24 Hour <48 Hour <3 Day 5 Day Other:
For Lab Use Only
Client ID # Lab ID# Description Location Acceptable on Receipt
Comments
1 69664 Puddy See COC 3 69664 Vapor Barrier 5 69664 Caulk 7 69664 Caulk 9 69664 Vapor Barrier 11 69664 Caulk
For Lab Use Only # Spies Total Client # Batch # Results Reported Comments mailto:KWilliamson@trccompanies.com mailto:SArienti@trccompanies.com mailto:EPlimpton@trccompanies.com mailto:DCarillo@trccompanies.com mailto:KGraff@trccompanies.com mailto:NBhura@trccompanies.com mailto:GKaczynski@trccompanies.com
21 Griffin Road North Windsor, CT 06095
(860) 298-6308
69742.CT-DOT.doc
Lab Log #: 0069742
Maintenance Facility Salt Shed, 150 Welles Road, Groton, CT
CLIENT: CT Department of Transportation
Site:
Date Analyzed:
Date Received:
06/04/2026
06/04/2026
Project #: 501871.8360.0710
BULK ASBESTOS ANALYSIS REPORT
Asbestos Type
Other Matrix MaterialsSample No.
Asbestos
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
Sample Location Homogeneous
Material Description
D side roof - - - None13 NDGrey RS1 - rubber roof membrane sealant
B side roof - - - None14 NDGrey RS1 - rubber roof membrane sealant
D side roof - - - None15 NDYellow G1 - rubber membrane glue on gypsum roof boards
B side roof - - - None16 NDYellow G1 - rubber membrane glue on gypsum roof boards
D side roof cellulose None17 ND5%Grey SHR1 - gypsum roof board
B side roof cellulose None18 ND5%Grey SHR1 - gypsum roof board
D side roof - - - None19 NDBlue VB3 - vapor barrier paper between gypsum roof board and plywood roof deck
B side roof - - - None20 NDBlue VB3 - vapor barrier paper between gypsum roof board and plywood roof deck
D side roof synthetic fiber None21 ND90%White IN1 - roof insulation under rubber room membrane
B side roof synthetic fiber None22 ND90%White IN1 - roof insulation under rubber room membrane
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0
RI #PLM00007 TX #300354
CO# AL-21772
AIHA LAP #100122
VT #An-000020
LA#05011
CT #PH-0426
VA #3333 000283
PA#68-03387
NY #10980
NV #CT00004
WA #C1071
WV #000622
CA #2907
ME LB-0071
AZ #AZ0944
PHIL#ALL-461
21 Griffin Road North Windsor, CT 06095
(860) 298-6308
69742.CT-DOT.doc
Asbestos Type
Other Matrix MaterialsSample No.
Asbestos
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
Sample Location Homogeneous
Material Description
Trace - asbestos was observed at level of 1% or less - This is the reporting limit NA/PS - Not Analyzed / Positive Stop SNA - Sample Not Analyzed- See Chain of Custody for details Notes: Asbestos-Containing Material (ACM) is any material containing more than 1% asbestos
The Laboratory at TRC follows 18/01A EPA -- 40 CFR Appendix E to subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples and 18/A03 EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials which utilize polarized light microscopy (PLM). Our analysts have completed an accredited course in asbestos identification. TRC's Laboratory is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), for Bulk Asbestos Fiber Analysis, NVLAP Code 101424-01. TRC is accredited by the AIHA Laboratory Accreditation Programs AIHA LAP (ID: LAP-100122) in the Industrial Hygiene Program (IHLAP) for PLM. Asbestos content is determined by visual estimate unless otherwise indicated. Quality Control is performed in-house on at least 10% of samples and QC data related to the samples is available upon written request from client.
This report shall not be reproduced, except in full, without the written approval of TRC. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report relates only to the items tested, as received by the laboratory.
ND - asbestos was not detected
Note: Polarized-light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. In those cases, EPA recommends, and certain states (e.g. NY) require, that negative results be confirmed by quantitative transmission electron microscopy.
Analyzed by: Reviewed by Date Issued
06/04/2026Najaat Bhura, Approved SignatoryKathleen Williamson, Laboratory Manager
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0
RI #PLM00007 TX #300354
CO# AL-21772
AIHA LAP #100122
VT #An-000020
LA#05011
CT #PH-0426
VA #3333 000283
PA#68-03387
NY #10980
NV #CT00004
WA #C1071
WV #000622
CA #2907
ME LB-0071
AZ #AZ0944
PHIL#ALL-461
EMSL
528 Mineola Ave, Carle Place, NY 11514 TEM Bulk Chain of Custody Record
Date: 06/04/2026
PO#: C501871 Analysis Type: TEM EPA N.O.B Client: CT DOT Client Job#: 501871.8360.0710 Client Job Ref./Loc. Maintenance Facility Salt Shed, Groton, CT Relinquished by: K. Williamson Received by:
Report to: KWilliamson@trccompanies.com; SArienti@trccompanies.com EPlimpton@trccompanies.com
DCarillo@trccompanies.com KGraff@trccompanies.com NBhura@trccompanies.com GKaczynski@trccompanies.com Sampler’s Name: T. Noll
Turnaround Time: <12 Hour <24 Hour <48 Hour <3 Day 5 Day Other:
For Lab Use Only
Client ID # Lab ID# Description Location Acceptable on Receipt
Comments
13 69742 Roof Membrane Sealant See COC 15 69742 Roof Membrane Glue 19 69742 Vapor Barrier
For Lab Use Only # Spies Total Client # Batch # Results Reported Comments mailto:KWilliamson@trccompanies.com mailto:EPlimpton@trccompanies.com mailto:DCarillo@trccompanies.com mailto:KGraff@trccompanies.com mailto:NBhura@trccompanies.com mailto:GKaczynski@trccompanies.com
APPENDIX G
ASBESTOS TEM LABORATORY ANALYSIS DATA
EMSL Analytical, Inc.
528 Mineola Avenue Carle Place, NY 11514
Tel/Fax: (516) 997-7251 / (516) 997-7528 http://www.EMSL.com / carleplacelab@emsl.com
EMSL Order: 062605633
Customer ID: TRC51
Customer PO: C501871
Project ID:
Attention: Kathleen Williamson Phone: (860) 298-9692
TRC Environmental Consultants Fax: (860) 298-6399
21 Griffin Road North Received Date: 05/27/2026 10:05 AM
Windsor, CT 06095 Analysis Date: 05/29/2026
Collected Date: 05/22/2026
501871.8360.0710, ConnDOT- Groton Maintenance, Facility Salt Shed, 150 Welles Rd, Groton CTProject:
Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by TEM via
EPA/600/R-93/116 Section 2.5.5.1
Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types
062605633-0001
A Side Electrical Panel
Conduits - EP 1- Black
Electrical Puddy on
Conduit Penetrations
Brown/Black
Non-Fibrous
Heterogeneous
100.0 None No Asbestos DetectedOther
062605633-0002
A Side Interior - VB1-
Black Vapor Barrier
Behind Interior Plywood
Panels
Black
Non-Fibrous
Heterogeneous
100.0 None No Asbestos DetectedOther
062605633-0003
B Side Exterior - C1- Grey
Exterior Caulk
Gray
Non-Fibrous
Heterogeneous
100.0 None No Asbestos DetectedOther
062605633-0004
C Side Exterior - C2 - Red
Louvre Caulk
Brown
Non-Fibrous
Homogeneous
100.0 None No Asbestos DetectedOther
062605633-0005
C Side Exterior - VB2 -
Black Vapor Berrier
Under Exterior Shakes
Black
Fibrous
Heterogeneous
100.0 None No Asbestos DetectedOther
062605633-0006
B Side Interior - C3 -
Black Support Beam
Base Caulk
Black
Non-Fibrous
Homogeneous
100.0 None No Asbestos DetectedOther
Analyst(s)
Cristhian Granda (6) Daniel Clarke, Asbestos Laboratory Manager or other approved signatory
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. EMSL recommends that samples reported as none detected or < 1% undergo additional analysis via PLM to avoid the possibility of false negatives.
Samples analyzed by EMSL Analytical, Inc. Carle Place, NY
Initial report from: 05/30/2026 10:37:24
ASB_PLMEPANOB_0012_0002 Printed 5/30/2026 10:38:50AM Page 1 of 1
OrderID: 062605633
OrderID: 062605633
EMSL Analytical, Inc.
528 Mineola Avenue Carle Place, NY 11514
Tel/Fax: (516) 997-7251 / (516) 997-7528 http://www.EMSL.com / carleplacelab@emsl.com
EMSL Order: 062605992
Customer ID: TRC51
Customer PO: 501871.8360.07
Project ID:
Attention: Kathleen Williamson Phone: (860) 298-9692
TRC Environmental Consultants Fax: (860) 298-6399
21 Griffin Road North Received Date: 06/05/2026 10:54 AM
Windsor, CT 06095 Analysis Date: 06/06/2026
Collected Date: 06/04/2026
501871.8360.0710; ConnDOT - Groton Maintenance Facility Salt Shed, 150 Welles Rd, Groton, CTProject:
Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by TEM via
EPA/600/R-93/116 Section 2.5.5.1
Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types
062605992-0001
D Side Roof - RS1 - Grey
Rubber Roof Membrane
Sealant
White/Black
Non-Fibrous
Heterogeneous
100.0 None No Asbestos DetectedOther
062605992-0002
D Side Roof - G1 - Yellow
Rubber Membrane Glue on Gypsum Roof Boards
Green/Beige
Non-Fibrous
Heterogeneous
100.0 None No Asbestos DetectedOther
062605992-0003
D Side Roof - VB3 - Blue
Vapor Barrier Paper
Gypsum Roof Board and
Plywood Roof Deck
White/Blue
Non-Fibrous
Heterogeneous
100.0 None No Asbestos DetectedOther
Analyst(s)
Luisa Vargas (3) Daniel Clarke, Asbestos Laboratory Manager or other approved signatory
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. EMSL recommends that samples reported as none detected or < 1% undergo additional analysis via PLM to avoid the possibility of false negatives.
Samples analyzed by EMSL Analytical, Inc. Carle Place, NY
Initial report from: 06/06/2026 13:03:50
ASB_PLMEPANOB_0012_0002 Printed 6/6/2026 1:05:22PM Page 1 of 1
APPENDIX H
LEAD PAINT XRF MEASUREMENT TABLE
Device(s) : Niton XLP301-A (Serial #22323) X Ray Fluorescence (XRF) Spectrum Analyzer Client : ConnDOT Site : Groton MF Salt Shed Project # : 501871.8360.0710 Date(s) : 5/22/2026 Inspector : Andrew Smith (LIC#2316)/Alexa Knight
1 Shutter Calibration 1.6 0.0 230.4 5/22/2026 9:28 2 0.0 Calibration 0.0 0.0 1.0 1.8 5/22/2026 9:32 3 1.6 Calibration 1.6 0.2 1.2 4.4 5/22/2026 9:33 4 0.7 Calibration 0.7 0.1 1.1 12.2 5/22/2026 9:34 5 Exterior A Pillar Metal Yellow 0.5 0.3 10.0 25.8 5/22/2026 9:38 6 Exterior A Pillar Metal Yellow 0.4 0.4 10.0 30.4 5/22/2026 9:40 7 Exterior A Siding Wood Brown 0.0 0.0 1.0 1.4 5/22/2026 9:44 8 Exterior A Siding Wood Brown 0.0 0.0 1.0 2.4 5/22/2026 9:44 9 Exterior A Electrical Box Metal Brown 0.0 0.0 1.0 2.5 5/22/2026 9:45 10 Exterior A Door Casing Wood White 0.0 0.0 1.0 1.6 5/22/2026 9:46 11 Exterior A Door Casing Wood White 0.0 0.0 1.0 0.4 5/22/2026 9:46 12 Exterior A Door Casing Wood White 0.0 0.0 1.0 1.4 5/22/2026 9:47 13 Exterior B Siding Shakes Brown 0.0 0.0 1.0 2.2 5/22/2026 9:48 14 Exterior B Siding Shakes Brown 0.0 0.0 1.0 2.5 5/22/2026 9:48 15 Exterior B Soffit Wood Brown 0.0 0.0 1.0 2.4 5/22/2026 9:50 16 Exterior B Soffit Wood Brown 0.0 0.0 1.0 1.3 5/22/2026 9:50 17 Exterior C Soffit Wood Brown 0.0 0.1 1.0 0.3 5/22/2026 9:52 18 Exterior C Soffit Wood Brown 0.0 0.0 1.0 1.3 5/22/2026 9:52 19 Exterior C Siding Shakes Brown 0.0 0.0 1.0 2.2 5/22/2026 9:53 20 Exterior D Siding Shakes Brown 0.0 0.0 1.0 2.2 5/22/2026 9:54 21 Exterior D Soffit Shakes Brown 0.0 0.0 1.0 2.0 5/22/2026 9:55 22 Exterior D Light Fixture Metal Black 0.0 0.1 1.4 0.3 5/22/2026 9:57 23 Exterior D Light Fixture Metal Black 0.1 0.3 2.7 0.4 5/22/2026 9:57
Lead Based Paint Measurement Summary Table
Date/TimeColor Reading (mg/cm2)
Precision (mg/cm2)
Depth Index
Duration (sec)Number Floor Side Structure Feature Material
Lead paint includes paint found to contain any detectable amount of lead by Atomic Absorption Spectrophotometry (AAS) or X-Ray Fluorescence (XRF). Side A = Street side; Sides B,C,D follow clockwise
Device(s) : Niton XLP301-A (Serial #22323) X Ray Fluorescence (XRF) Spectrum Analyzer Client : ConnDOT Site : Groton MF Salt Shed Project # : 501871.8360.0710 Date(s) : 5/22/2026 Inspector : Andrew Smith (LIC#2316)/Alexa Knight
Lead Based Paint Measurement Summary Table
Date/TimeColor Reading (mg/cm2)
Precision (mg/cm2)
Depth Index
Duration (sec)Number Floor Side Structure Feature Material
24 Void 25 Exterior D Light Fixture Metal Black 0.0 0.1 4.4 2.5 5/22/2026 9:58 26 Void 27 Void 28 0.0 Calibration 0.0 0.0 1.0 1.4 5/22/2026 10:54 29 1.6 Calibration 1.5 0.3 1.1 2.7 5/22/2026 10:54 30 0.7 Calibration 0.6 0.1 1.0 6.6 5/22/2026 10:55
Lead paint includes paint found to contain any detectable amount of lead by Atomic Absorption Spectrophotometry (AAS) or X-Ray Fluorescence (XRF). Side A = Street side; Sides B,C,D follow clockwise
APPENDIX I
COMPOSITE BUILDING MATERIAL
WASTE CHARACTERIZATION DATA
APPENDIX J
RELATED CORRESPONDENCE
This is an External email. Do not click links or open attachments unless you validate the sender and know the content is safe.
ALWAYS hover over the link to preview the actual URL/site and confirm its legitimacy.
From: Arienti, Stephen To: Imig, Daniel R.
Cc: Plimpton, Erik; Gentile, Jonathan; Kaczynski, Gregory; Silverman, Benjamin L.
Subject: RE: [EXTERNAL] Scope Change for 0172-0544 Groton/Stonington Maintenance Facility Date: Tuesday, May 26, 2026 8:53:39 AM Attachments: image001.png image002.png image003.png
Morning Dan, All went well.
No issues.
We held off on touching the roof which sounds like was the right move according to Mike Strong.
We will get the other samples in for now.
Thank you, SIH New England Regional Area Leader Environmental, Health, Safety, and Sustainability (EHS&S)
21 Griffin Road North, Windsor, CT 06095 T 860.298.9692 | C 860.508.9240 | sarienti@trccompanies.com LinkedIn | Instagram | TRCcompanies.com
From: Imig, Daniel R. <Daniel.Imig@ct.gov> Sent: Tuesday, May 26, 2026 8:51 AM To: Arienti, Stephen <SArienti@trccompanies.com> Cc: Plimpton, Erik <EPlimpton@trccompanies.com>; Gentile, Jonathan <JGentile@trccompanies.com>; Kaczynski, Gregory <GKaczynski@trccompanies.com>; Silverman, Benjamin L. <Benjamin.Silverman@ct.gov> Subject: RE: [EXTERNAL] Scope Change for 0172-0544 Groton/Stonington Maintenance Facility
Good morning - How did it go on Friday?
Daniel Imig, P.E.
Supervising Engineer Environmental Compliance Section Connecticut Department Of Transportation 2800 Berlin Turnpike Newington, CT 06131 P: 860.594.3455 mailto:Daniel.Imig@ct.gov mailto:EPlimpton@trccompanies.com mailto:JGentile@trccompanies.com mailto:GKaczynski@trccompanies.com mailto:Benjamin.Silverman@ct.gov mailto:sarienti@trccompanies.com http://www.linkedin.com/company/trc-companies-inc https://www.instagram.com/trc_companies/ http://www.trccompanies.com/
This is an External email. Do not click links or open attachments unless you validate the sender and know the
ALWAYS hover over the link to preview the actual URL/site and confirm its legitimacy.
From: Arienti, Stephen <SArienti@trccompanies.com> Sent: Thursday, May 21, 2026 4:09 PM To: Imig, Daniel R. <Daniel.Imig@ct.gov>; Silverman, Benjamin L. <Benjamin.Silverman@ct.gov> Cc: Plimpton, Erik <EPlimpton@trccompanies.com>; Gentile, Jonathan <jgentile@trccompanies.com>; Kaczynski, Gregory <gkaczynski@trccompanies.com>
EXTERNAL EMAIL: This email originated from outside of the organization. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
Sounds good.
Yeah we would want to get destructive to see all the layers. I was just thinking the edges since the roof looks to be homogeneous and the edges might be a better spot since it wouldn’t be over the salt.
Sent: Thursday, May 21, 2026 4:01 PM To: Arienti, Stephen <SArienti@trccompanies.com>; Silverman, Benjamin L. <Benjamin.Silverman@ct.gov> Cc: Plimpton, Erik <EPlimpton@trccompanies.com>; Gentile, Jonathan <JGentile@trccompanies.com>; Kaczynski, Gregory <GKaczynski@trccompanies.com>
Assume you are doing the destructive testing near the edges. Not sure how long the salt shed will stay up. I will do some reaching out and be in touch if we want to back off and not do it.
Environmental Compliance Section Connecticut Department Of Transportation 2800 Berlin Turnpike
From: Arienti, Stephen <SArienti@trccompanies.com> Sent: Thursday, May 21, 2026 3:44 PM To: Imig, Daniel R. <Daniel.Imig@ct.gov>; Silverman, Benjamin L. <Benjamin.Silverman@ct.gov> mailto:SArienti@trccompanies.com mailto:Daniel.Imig@ct.gov mailto:Benjamin.Silverman@ct.gov mailto:EPlimpton@trccompanies.com mailto:jgentile@trccompanies.com mailto:gkaczynski@trccompanies.com mailto:sarienti@trccompanies.com https://urldefense.com/v3/__http:/www.linkedin.com/company/trc-companies-inc__;!!EAPaXxOOW7smCwU!ksHtIJJRbZH4RqY8ebCHwr1PerqY-Yy8qvrSIdZmw6LavDWe7zKuXRtY9NxZHomtXVawKlAs2Zoe6DF5BgD8ErY$ https://urldefense.com/v3/__https:/www.instagram.com/trc_companies/__;!!EAPaXxOOW7smCwU!ksHtIJJRbZH4RqY8ebCHwr1PerqY-Yy8qvrSIdZmw6LavDWe7zKuXRtY9NxZHomtXVawKlAs2Zoe6DF5_fo3VFI$ https://urldefense.com/v3/__http:/www.trccompanies.com/__;!!EAPaXxOOW7smCwU!ksHtIJJRbZH4RqY8ebCHwr1PerqY-Yy8qvrSIdZmw6LavDWe7zKuXRtY9NxZHomtXVawKlAs2Zoe6DF5bTt7aWc$ mailto:Daniel.Imig@ct.gov mailto:SArienti@trccompanies.com mailto:Benjamin.Silverman@ct.gov mailto:EPlimpton@trccompanies.com mailto:JGentile@trccompanies.com mailto:GKaczynski@trccompanies.com mailto:SArienti@trccompanies.com mailto:Benjamin.Silverman@ct.gov
This is an External email. Do not click links or open attachments unless you validate the sender and know the
ALWAYS hover over the link to preview the actual URL/site and confirm its legitimacy.
Cc: Plimpton, Erik <EPlimpton@trccompanies.com>; Gentile, Jonathan <jgentile@trccompanies.com>; Kaczynski, Gregory <gkaczynski@trccompanies.com>
EXTERNAL EMAIL: This email originated from outside of the organization. Do not click any links or open any attachments unless you trust the sender
Thank you.
Lastly, I wanted to ask about sampling the roof for asbestos. The report indicts that a new roof was put on the salt shed back in 2019 and has a warranty on it. I know we get no asbestos letters for the products when they do those projects too. We can cut into the roof near the edges to inspect for suspect materials and try our best to patch those areas, but just wanted to run it by Ben and you.
I know eventually it is going to be demolished but I assume it might not be for a while.
Sent: Thursday, May 21, 2026 3:27 PM To: Arienti, Stephen <SArienti@trccompanies.com>; Silverman, Benjamin L. <Benjamin.Silverman@ct.gov> Cc: Plimpton, Erik <EPlimpton@trccompanies.com>; Gentile, Jonathan <JGentile@trccompanies.com>; Kaczynski, Gregory <GKaczynski@trccompanies.com>
Should be fine. I sent an email to the GS and left him a vm so he knows you are coming.
Environmental Compliance Section Connecticut Department Of Transportation 2800 Berlin Turnpike
Sent: Thursday, May 21, 2026 2:47 PM To: Silverman, Benjamin L. <Benjamin.Silverman@ct.gov> mailto:EPlimpton@trccompanies.com mailto:jgentile@trccompanies.com mailto:gkaczynski@trccompanies.com mailto:sarienti@trccompanies.com https://urldefense.com/v3/__http:/www.linkedin.com/company/trc-companies-inc__;!!EAPaXxOOW7smCwU!hQ2lfrrkDNMsXmD6q17VF0vjHdBCCESfotUyiQyp64mHWgIV5-wILtqr00DeSrs3s1zORKhBFXKhGIFsaANrbJ4$ https://urldefense.com/v3/__https:/www.instagram.com/trc_companies/__;!!EAPaXxOOW7smCwU!hQ2lfrrkDNMsXmD6q17VF0vjHdBCCESfotUyiQyp64mHWgIV5-wILtqr00DeSrs3s1zORKhBFXKhGIFsNLP2-hY$ https://urldefense.com/v3/__http:/www.trccompanies.com/__;!!EAPaXxOOW7smCwU!hQ2lfrrkDNMsXmD6q17VF0vjHdBCCESfotUyiQyp64mHWgIV5-wILtqr00DeSrs3s1zORKhBFXKhGIFsTog_67U$ mailto:Daniel.Imig@ct.gov mailto:SArienti@trccompanies.com mailto:Benjamin.Silverman@ct.gov mailto:EPlimpton@trccompanies.com mailto:JGentile@trccompanies.com mailto:GKaczynski@trccompanies.com mailto:Benjamin.Silverman@ct.gov
This is an External email. Do not click links or open attachments unless you validate the sender and know the
ALWAYS hover over the link to preview the actual URL/site and confirm its legitimacy.
Cc: Plimpton, Erik <EPlimpton@trccompanies.com>; Gentile, Jonathan <jgentile@trccompanies.com>; Kaczynski, Gregory <gkaczynski@trccompanies.com>; Imig, Daniel R. <Daniel.Imig@ct.gov>
EXTERNAL EMAIL: This email originated from outside of the organization. Do not click any links or open any attachments unless you trust the sender
Afternoon Ben, We plan to send a crew out tomorrow to the Groton Salt Shed, if that works for everyone.
Let us know.
From: Silverman, Benjamin L. <Benjamin.Silverman@ct.gov> Sent: Wednesday, May 20, 2026 11:00 AM To: Arienti, Stephen <SArienti@trccompanies.com> Cc: Plimpton, Erik <EPlimpton@trccompanies.com>; Gentile, Jonathan <JGentile@trccompanies.com>; Kaczynski, Gregory <GKaczynski@trccompanies.com>; Imig, Daniel R. <Daniel.Imig@ct.gov>
Good morning, Please see the attached plan showing the final condition after the salt shed is demolished. I’ve also attached the most recent inspection report for the building. That’s all we have. Is this enough for you to complete the inspection?
Ben Silverman Transportation Engineer 2 Connecticut Department of Transportation Environmental Compliance Unit Office: 860-594-2763 Cell: 774-249-1753 benjamin.silverman@ct.gov
Sent: Tuesday, May 19, 2026 11:18 AM To: Silverman, Benjamin L. <Benjamin.Silverman@ct.gov> Cc: Plimpton, Erik <EPlimpton@trccompanies.com>; Gentile, Jonathan <jgentile@trccompanies.com>; Kaczynski, Gregory <gkaczynski@trccompanies.com>; Imig, Daniel R. <Daniel.Imig@ct.gov> Subject: RE: [EXTERNAL] Scope Change for 0172-0544 Groton/Stonington Maintenance Facility mailto:EPlimpton@trccompanies.com mailto:jgentile@trccompanies.com mailto:gkaczynski@trccompanies.com mailto:Daniel.Imig@ct.gov mailto:sarienti@trccompanies.com https://urldefense.com/v3/__http:/www.linkedin.com/company/trc-companies-inc__;!!EAPaXxOOW7smCwU!iOqQAvIGqUnuzlsvk7NKm0P0DXCbBQwH1VoF_HGWvO6fVXP1WplATqqq89xXbwDueAJNuJCa1CrXKGJxeD7cQvQ$ https://urldefense.com/v3/__https:/www.instagram.com/trc_companies/__;!!EAPaXxOOW7smCwU!iOqQAvIGqUnuzlsvk7NKm0P0DXCbBQwH1VoF_HGWvO6fVXP1WplATqqq89xXbwDueAJNuJCa1CrXKGJx4Rj69bE$ https://urldefense.com/v3/__http:/www.trccompanies.com/__;!!EAPaXxOOW7smCwU!iOqQAvIGqUnuzlsvk7NKm0P0DXCbBQwH1VoF_HGWvO6fVXP1WplATqqq89xXbwDueAJNuJCa1CrXKGJxwbUnqpM$ mailto:Benjamin.Silverman@ct.gov mailto:SArienti@trccompanies.com mailto:EPlimpton@trccompanies.com mailto:JGentile@trccompanies.com mailto:GKaczynski@trccompanies.com mailto:Daniel.Imig@ct.gov mailto:benjamin.silverman@ct.gov mailto:SArienti@trccompanies.com mailto:Benjamin.Silverman@ct.gov mailto:EPlimpton@trccompanies.com mailto:jgentile@trccompanies.com mailto:gkaczynski@trccompanies.com
This is an External email. Do not click links or open attachments unless you validate the sender and know the
ALWAYS hover over the link to preview the actual URL/site and confirm its legitimacy.
EXTERNAL EMAIL: This email originated from outside of the organization. Do not click any links or open any attachments unless you trust the sender
No problem. We still have some funds left under 524-8360 for Task 710/720 that we should be able to make work.
I tried to get into Compass for the project and it says no access. Anything you can find will be helpful.
Thanks, From: Silverman, Benjamin L. <Benjamin.Silverman@ct.gov> Sent: Tuesday, May 19, 2026 10:56 AM To: Arienti, Stephen <SArienti@trccompanies.com> Cc: Plimpton, Erik <EPlimpton@trccompanies.com>; Gentile, Jonathan <JGentile@trccompanies.com>; Kaczynski, Gregory <GKaczynski@trccompanies.com>; Imig, Daniel R. <Daniel.Imig@ct.gov> Subject: [EXTERNAL] Scope Change for 0172-0544 Groton/Stonington Maintenance Facility Importance: High
Hi Steve, Busy times… I was just informed the project has added the demolition of the salt shed in Groton to their scope. They’ve asked for the supporting inspection to be completed ASAP. I have reached out for any helpful, tangible information (such as plans) and if I get anything I will forward it to you. Do you need a Mod for this effort? Please let me know.
Thanks, Ben Silverman Transportation Engineer 2 Connecticut Department of Transportation Environmental Compliance Unit Office: 860-594-2763 Cell: 774-249-1753 benjamin.silverman@ct.gov mailto:sarienti@trccompanies.com https://urldefense.com/v3/__http:/www.linkedin.com/company/trc-companies-inc__;!!EAPaXxOOW7smCwU!kw8fQwhZ-ebItjabj3K9FZRfMH__7CwJTpy-83UWZyQSx4ALoBo5WuDu-JP6BGNPiMENqKDF6oKbH-m9IF4IYZD78Rhe$ https://urldefense.com/v3/__https:/www.instagram.com/trc_companies/__;!!EAPaXxOOW7smCwU!kw8fQwhZ-ebItjabj3K9FZRfMH__7CwJTpy-83UWZyQSx4ALoBo5WuDu-JP6BGNPiMENqKDF6oKbH-m9IF4IYaXsaUy4$ https://urldefense.com/v3/__http:/www.trccompanies.com/__;!!EAPaXxOOW7smCwU!kw8fQwhZ-ebItjabj3K9FZRfMH__7CwJTpy-83UWZyQSx4ALoBo5WuDu-JP6BGNPiMENqKDF6oKbH-m9IF4IYZ2Qiez0$ mailto:Benjamin.Silverman@ct.gov mailto:SArienti@trccompanies.com mailto:EPlimpton@trccompanies.com mailto:JGentile@trccompanies.com mailto:GKaczynski@trccompanies.com mailto:benjamin.silverman@ct.gov
SIH - WinSIH HBM Survey ConnDOT, Groton Maintenance Facility Salt Shed, 150 Welles Rd Groton CT
6/4/2026, 6:38:49 PM UTC
CREATED
5/22/2026, 1:09:43 PM UTC
by Andrew Smith
UPDATED
6/4/2026, 6:38:49 PM UTC
by Kathleen Williamson
STATUS
Complete
ASSIGNED TO
No Assignment
JOB INFORMATION
Site Name Groton Maintenance Facility Salt Shed
Address 150 Welles Rd Groton CT
TRC Project Number 501871.8360.0710
Project Manager Stephen Arienti, Erik Plimpton
Inspector(s) Andrew Smith, Tyler Noll
Client ConnDOT
Type of Asbestos Survey Reno/Demo
Site Sketch Diagrams
Additional Analysis for NOB Materials (Calc)
TEM NY NOB 198.4
PLM Turnaround Time (TAT) 3-day
TEM Turnaround Time (TAT) 3-day
Date May 22, 2026
General Notes Post at front of shed have metal jacket around concrete. Unable to verify if concrete is painted.
Overview Photo
Options & Other Settings
Use auto-numbering? No
Auto-fill gaps? Yes
Alert user about missing site sketch? Yes
SURVEYS PERFORMED Asbestos, LCP, Hazardous Materials Inventory, Demolition Items
Asbestos Survey
Materials & Samples (11 Items)
Materials & Samples - 1. (2) Samples #1–2: EP 1–Black electrical puddy on conduit penetrations
Sample Information
Asbestos Samples (2 Items)
Asbestos Samples - 1. Sample #1: EP 1…A side electrical panel conduits
Sample Number 1
Sample Location A side electrical panel conduits
Asbestos Bulk Analysis PLM EPA 600/R93/116
Grab or Composite Grab
Date May 22, 2026
Time 10:14
Sample Location Photo
Asbestos Samples - 2. Sample #2: EP 1…A side electrical panel conduits
Sample Number 2
Sample Location A side electrical panel conduits
Asbestos Bulk Analysis PLM EPA 600/R93/116
Grab or Composite Grab
Date May 22, 2026
Time 10:14
Sample Location Photo
Material Information
Sampled or Assumed? Sampled
Material Acronym EP 1
Material Description Black electrical puddy on conduit penetrations
Material Color Black
Representative Photos
Analyze by layer? No
Is material non-friable organically bound (NOB)?
Yes
Homogeneous Area
Total Approximate Quantity
Notes
Materials & Samples - 2. (2) Samples #3–4: VB1–Black vapor barrier behind interior plywood panels
Sample Information
Asbestos Samples (2 Items)
Asbestos Samples - 1. Sample #3: VB1…A side interior
Sample Number 3
Sample Location A side interior
Asbestos Bulk…