01_SCCP_BID_SET_DRAWINGS_Part3~3.pdf
PDF 27 MB Posted
- Attached to
- Class 6 Cargo Truck Purchase
- Solicitation number
- S-177000-00008330
- Issued by
- Marion County, Oregon
About this file
This document is a comprehensive set of construction bid drawings and specifications for the Santa Clara Community Park Phase I project in Eugene, Oregon, involving multiple design disciplines including structural, architectural, plumbing, mechanical, and electrical systems. The project encompasses the construction of a pedestrian bridge, a 980 square-foot restroom and service building, and associated site improvements including lighting, drainage, and utilities. The bid set includes detailed structural drawings for a contractor-designed steel-framed pedestrian bridge with concrete end panels and wing walls, foundation plans for a concrete slab-on-grade restroom building with concrete masonry unit (CMU) walls, and comprehensive MEP (mechanical, electrical, plumbing) coordination drawings. The restroom building includes three family restrooms, a service core with storage, and a service chase, with specifications for concrete strength (4,000 PSI), reinforcing steel details, and construction sequences. The document package includes foundation and floor plans, roof framing plans, interior and exterior elevations, detailed sections, and equipment schedules for all building systems.
Pricing for this project will be based on lump-sum or unit pricing as established through the competitive bidding process, with contractors responsible for all substructure installation, metering equipment, and service laterals including trenching, conduit installation, and electrical connections. The specifications require compliance with the Oregon Structural Specialty Code (OSSC), AASHTO guidelines for pedestrian bridge design, and current building codes including ASHRAE 90.1-2019 for energy efficiency. Key design criteria include an H10 design vehicle load for the bridge, a 90 PSF pedestrian live load, and 150 PCF concrete self-weight. Contractors must submit shop drawings, concrete mix designs, and delegated design submittals bearing professional engineer seals for approval prior to fabrication. The project includes special inspection requirements for structural masonry and concrete placement, with the Structural Engineer of Record performing observations at critical construction stages. No specific funding source or budget ceiling is identified in the drawings, though the scope suggests a substantial capital project involving coordination between landscape architecture, civil, structural, and building system designers.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 20028_Truck ITB 2024_Final.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AS NOTED
K:\2022\10022200439\Drafting\10022200439_S0-01.dwg Anthony Do 9/25/2023 2:52 PM
DateRev. # By
SA
N
TA
C
LA
R
A C
O M
M U
N
IT
Y
PA
R K
- P H
AS
E
I
10022200439
09/29/2023DATE:
SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT #:
AT
AD
SF
111 SW Fifth Ave., Suite 2600 Portland, OR 97204
O: 503.227.3251 F: 503.227.7980 www.kpff.com
DRAWING INDEX
AND GENERAL
STRUCTURAL
NOTES
S0.01
GENERAL
STRUCTURAL DRAWINGS ARE A PART OF THE CONTRACT DOCUMENTS AND ARE COMPLEMENTARY TO THE LANDSCAPE ARCHITECTURE AND CIVIL DRAWINGS, THE SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE REQUIREMENTS FROM THE CONTRACT DOCUMENTS INTO THEIR SHOP DRAWINGS AND WORK. AS REQUIRED BY THE GENERAL CONDITIONS, THE CONTRACTOR SHALL PROMPTLY REPORT TO THE CITY PROJECT MANAGER ANY ERRORS, INCONSISTENCIES, OR OMISSIONS IN THE CONTRACT DOCUMENTS
DISCOVERED BY OR MADE KNOWN TO THE CONTRACTOR.
THE GENERAL STRUCTURAL NOTES SUPPLEMENT THE PROJECT SPECIFICATIONS. REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER THE GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE GIVEN, CONSTRUCTION SHALL BE AS SHOWN FOR SIMILAR WORK. WHERE CONFLICT EXISTS, THE MORE STRINGENT OR
RESTRICTIVE REQUIREMENT SHALL GOVERN UNITL CLARIFICATION IS REQUESTED.
CODE REQUIREMENTS:
CONFORM TO THE AASHTO LRFD GUIDE SPECIFICATIONS FOR THE DESIGN OF PEDESTRIAN BRIDGES, 2ND EDITION.
TEMPORARY CONDITIONS:
THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE
CONTRACTOR'S CONSTRUCTION METHODS AND/OR SEQUENCES UNTIL COMPLETION.
CONTRACTOR'S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER THE EFFECTS OF
THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PERIOD.
ASSUMED FUTURE CONSTRUCTION:
VERTICAL: NONE
HORIZONTAL: NONE
DESIGN CRITERIA
DESIGN WAS BASED ON THE STRENGTH AND DEFLECTION CRITERIA OF THE OSSC. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS AND ALLOWABLES WERE USED FOR DESIGN, WITH LIVE LOADS (L.L.) REDUCED PER OSSC:
GRAVITY SYSTEM CRITERIA
OCCUPANCY OR USE UNIFORM LOAD CONCENTRATED LOAD
PEDESTRIAN 90 PSF L.L. -
SERVICE VEHICLE - H10 DESIGN VEHICLE
CONCRETE SELF-WEIGHT 150 PCF D.L. -
SOIL SELF-WEIGHT 120 PCF D.L. -
STRUCTURAL OBSERVATIONS
THE STRUCTURAL ENGINEER OF RECORD (SEOR) WILL PERFORM STRUCTURAL OBSERVATIONS BASED ON THE REQUIREMENTS OF THE OSSC AT THE STAGES OF CONSTRUCTION LISTED BELOW. CONTRACTOR SHALL PROVIDE SUFFICIENT ADVANCED NOTICE AND ACCESS FOR THE SEOR TO PERFORM THESE OBSERVATIONS.
ITEM COMMENTS
PRIOR TO FIRST CONCRETE POUR AFTER REBAR PLACEMENT
AS REQUIRED TO ADDRESS STRUCTURAL ISSUES
A FIELD REPORT WILL BE SUBMITTED TO THE BUILDING DEPARTMENT FOLLOWING EACH SITE VISIT.
STRUCTURAL OBSERVATION IS FOR THE GENERAL CONFORMANCE OF THE STRUCTURAL DRAWINGS AND DOES NOT
ALLEVIATE ANY SPECIAL INSPECTION REQUIREMENTS.
SPECIAL INSPECTIONS AND TESTING
SPECIAL INSPECTION WILL BE PROVIDED BY THE OWNER BASED ON THE REQUIREMENTS OF THE OSSC. CONTRACTOR SHALL PROVIDE SUFFICIENT NOTICE AND ACCESS FOR THE SPECIAL INSPECTOR TO PERFORM THESE INSPECTIONS.
SUBMITTALS
SUBMIT SHOP DRAWINGS AND OTHER SUBMITTALS TO THE ARCHITECT AND ENGINEER PRIOR TO FABRICATION AND CONSTRUCTION OF STRUCTURAL ITEMS. IF THE SUBMITTALS DIFFER FROM OR ADD TO THE STRUCTURAL CONTRACT DOCUMENTS, THEY SHALL BEAR THE SEAL AND SIGNATURE OF A STRUCTURAL ENGINEER REGISTERED IN THE STATE OF OREGON. ANY CHANGES TO THE STRUCTURAL DRAWINGS SHALL BE SUBMITTED TO THE PROJECT MANAGER AND ARE SUBJECT
TO REVIEW AND ACCEPTANCE BY THE SEOR.
FIELD ENGINEERED DETAILS DEVELOPED BY THE CONTRACTOR THAT DIFFER FROM OR ADD TO THE STRUCTURAL DRAWINGS SHALL BEAR THE SEAL AND SIGNATURE OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF OREGON AND SHALL BE
SUBMITTED TO THE ARCHITECT PRIOR TO CONSTRUCTION.
THE USE OF REPRODUCTIONS OR PHOTOCOPIES OF THE CONTRACT DRAWINGS SHALL NOT BE PERMITTED. WHEN CAD OR REVIT FILES ARE PROVIDED TO THE CONTRACTOR OR SUBCONTRACTORS, IT IS THE RESPONSIBILITY OF THE CONTRACTOR/SUBCONTRACTOR TO REMOVE ALL INFORMATION NOT DIRECTLY RELEVANT TO THE SCOPE OF THE SUBMITTAL
AS WELL AS ALL REFERENCES TO OUTSIDE SOURCE FILES.
DELEGATED DESIGN SUBMITTALS SHALL INCLUDE DESIGN DRAWINGS AND CALCULATIONS FOR ITEMS THAT ARE DESIGNED BY OTHERS. DELEGATED DESIGN SUBMITTALS SHALL BEAR THE SEAL AND SIGNATURE OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF OREGON ON EVERY DRAWING SHEET AND ON THE CALCULATION COVER SHEET, AND SHALL BE SUBMITTED TO THE PROJECT MANAGER AND ENGINEER PRIOR TO FABRICATION. CALCULATIONS AND DETAILS SHALL BE INCLUDED FOR ALL CONNECTIONS TO THE STRUCTURE, CONSIDERING LOCALIZED EFFECTS ON STRUCTURAL ELEMENTS.
DESIGN SHALL BE BASED ON THE REQUIREMENTS OF THE OSSC AND AS NOTED UNDER "DESIGN CRITERIA".
SUBMITTALS
SUBMITTALS AND DELEGATED DESIGN SUBMITTALS SHALL INCLUDE THE FOLLOWING:
ITEM SUBMITTAL
DELEGATED
DESIGN
SUBMITTAL
COMMENTS
CONTRACTOR DESIGNED PEDESTRIAN BRIDGE X
CONCRETE MIX DESIGNS X
CONCRETE REINFORCEMENT X
CONCRETE ANCHORAGES X
EMBEDDED STEEL ITEMS X
CONSTRUCTION JOINT LAYOUT X
CONCRETE MIX DESIGNS
CONCRETE WORK SHALL CONFORM TO CHAPTER 19 OF THE OSSC. CONCRETE STRENGTHS SHALL BE VERIFIED BY STANDARD CYLINDER TESTS PER ASTM C39. CONCRETE MIX TO BE DESIGNED AND PROPORTIONED BY THE CONTRACTOR IN ACCORDANCE WITH ACI 318-14 CHAPTER 26, ACI 301-16
CHAPTER 4 AND THE FOLLOWING INFORMATION:
USE f'c
(PSI)
TEST AGE
(DAYS)
MAX. W/CM
RATIO
MAX. AGG.
SIZE EXPOSURE CLASS
ALL CONCRETE 4,000 28 0.45 3/4" F2 S0 W1 C1
TABLE NOTES:
1. REF. ACI 318-14 TABLE 19.3.2.1 FOR ADDITIONAL MIX REQUIREMENTS SPECIFIC TO EXPOSURE CLASS.
2. ALL CONCRETE MIXES TO BE NORMAL WEIGHT CONCRETE, U.N.O.
3 ESTABLISH WATER-CEMENTITIOUS MATERIAL RATIO PER ACI 301-16 CHAPTER 4.
8. VERIFY WATER-CEMENTITIOUS MATERIAL RATIO WITH FLOOR COVERING MANUFACTURER FOR CONCRETE FLOORS WITH MOISTURE
SENSITIVE FLOOR COVERINGS.
9. REFERENCE SLABS EXPOSED TO VIEW GENERAL NOTES FOR ADDITIONAL MIX REQUIREMENTS.
PORTLAND CEMENT CONTENT MAY BE REPLACED WITH FLY ASH CONFORMING TO ASTM C618 (INCLUDING TABLE 2A) TYPE F OR TYPE C, SLAG CEMENT CONFORMING TO ASTM C989, AND SILICA FUME CONFORMING TO ASTM C1240 PROVIDED THAT THE MIX STRENGTH IS SUBSTANTIATED BY TEST DATA.
FOR MIX DESIGNS WITH f'c = 5,000 PSI OR LESS, SLAG CEMENT MAY BE SUBSTITUTED FOR FLY ASH AT A 1:1 RATIO WITHOUT TEST DATA. WHEN SLAG CEMENT IS SUBSTITUTED IN HIGHER STRENGTH MIXES OR AT A DIFFERENT RATIO, THE MIX STRENGTH MUST BE SUBSTANTIATED BY TEST DATA.
LIMITS ON CEMENTITIOUS MATERIALS FOR CONCRETE
ASSIGNED TO EXPOSURE CLASS F3
CEMENTITIOUS MATERIALS MAXIMUM PERCENT OF TOTAL CEMENTITIOUS
MATERIALS BY MASS
FLY ASH OR OTHER POZZOLANS CONFORMING TO ASTM C618 25%
SLAG CEMENT CONFORMING TO ASTM C989 50%
SILICA FUME CONFORMING TO ASTM C1240 10%
TOTAL OF FLY ASH OR OTHER POZZOLANS AND SILICA FUME 35%
TOTAL OF FLY ASH OR OTHER POZZOLANS, SLAG CEMENT, AND SILICA FUME 50%
ALL CONCRETE SUBJECT TO EXPOSURE CLASSES F1, F2 OR F3 SHALL BE AIR ENTRAINED. AIR-ENTRAINING AGENTS SHALL CONFORM TO ASTM C260. THE AMOUNT OF ENTRAINED AIR SHALL BE ACCORDING TO ACI 318-14 TABLE 19.3.3.1 AS INDICATED BELOW WITH A FIELD TOLERANCE OF ± 1.5 PERCENT BY VOLUME. THE AMOUNT OF ENTRAINED AIR SHALL BE MEASURED IN THE FIELD AT THE DISCHARGE FROM THE TRUCK.
CONCRETE MIX AIR CONTENT
MAX. AGGREGATE SIZE CONCRETE SUBJECT TO CONT. MOISTURE AND/OR DEICING CHEMICALS
(EXPOSURE CLASS F2 AND F3)
3/8" 7.5%
1/2" 7.0%
3/4" 6.0%
1" 6.0%
1-1/2" 5.5%
CONCRETE MIX AIR CONTENT MAY BE REDUCED BY 1.0% FOR f'c > 5,000 psi.
THE CONTRACTOR SHALL SUBMIT CONCRETE MIX DESIGNS ALONG WITH TEST DATA COMPLIANT WITH ACI 301-16 AND ACI 318-14 A MINIMUM OF TWO WEEKS PRIOR TO PLACING CONCRETE. NO WATER MAY BE ADDED TO CONCRETE IN THE FIELD UNLESS SPECIFICALLY APPROVED IN WRITING BY THE
CONCRETE SUPPLIER AND SEOR IN CONJUNCTION WITH THE CONCRETE MIX DESIGN.
DRAWING INDEX
S0.01 DRAWING INDEX AND GENERAL
STRUCTURAL NOTES
S0.02 GENERAL STRUCTURAL NOTES
S2.01 PLAN AND ELEVATION
S5.01 DETAILS
S5.02 DETAILS
S6.01 BRIDGE DETAILS
H10 DESIGN VEHICLE
4 KIPS 16 KIPS
4 KIPS 8 KIPS
2 KIPS 8 KIPS
6' -0
14'-0"
12/31/23
AS NOTED
K:\2022\10022200439\Drafting\10022200439_S0-02.dwg Anthony Do 9/25/2023 2:52 PM
DateRev. # By
SA
N
TA
C
LA
R
A C
O M
M U
N
IT
Y
PA
R K
- P H
AS
E
I
10022200439
09/29/2023DATE:
SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT #:
AT
AD
SF
111 SW Fifth Ave., Suite 2600 Portland, OR 97204
O: 503.227.3251 F: 503.227.7980 www.kpff.com
GENERAL
STRUCTURAL
NOTES
S0.02
CONCRETE REINFORCING STEEL
CONCRETE REINFORCEMENT SHALL BE ASTM A615 UNCOATED.
ALL REINFORCING STEEL SHALL BE SECURELY TIED IN PLACE WITH #16 ANNEALED IRON WIRE. BARS IN BEAMS AND SLABS SHALL BE SUPPORTED ON WELL-CURED CONCRETE BLOCKS OR APPROVED METAL OR PLASTIC CHAIRS, AS SPECIFIED BY THE CRSI MANUAL OF STANDARD PRACTICE, MSP-1. REINFORCING STEEL SHALL BE DETAILED IN ACCORDANCE WITH ACI MNL-66 "ACI DETAILING MANUAL". SHOP DRAWINGS SHALL INCLUDE
ELEVATIONS OF ALL BEAMS, WALLS AND COLUMNS SHOWING BAR LOCATIONS.
REINFORCING BARS SHALL NOT BE BENT OR STRAIGHTENED IN THE FIELD WITHOUT APPROVAL OF THE SEOR. PREHEATING METHODS SHALL BE
SUBMITTED TO THE SEOR FOR APPROVAL PRIOR TO BENDING OF BARS #6 OR LARGER.
LAP ALL REINFORCING BARS PER THE TYPICAL LAP SPLICE LENGTH SCHEDULES, EXCEPT AS NOTED ON DRAWINGS. USE LAP LENGTH FOR SMALLER BAR WHEN SPLICING DIFFERENT BAR SIZES. BARS SPLICED WITH NONCONTACT LAPS SHALL BE SPACED NO FARTHER THAN 1/5TH THE LAP LENGTH OR 6 INCHES. MECHANICAL SPLICES NOTED ON THE PLANS SHALL BE DAYTON SUPERIOR BAR-LOCK OR TAPER-LOCK COUPLERS (UES ER-319) OR
APPROVED EQUAL WITH A CURRENT EVALUATION REPORT.
TYP. WALL AND SLAB LAP SPLICE LENGTH SCHEDULE (IN.) - 60 KSI
BAR
SIZE
ALL REINFORCING STEEL
4,000
PSI
#3 16
#4 26
#5 32
#6 38
TABLE NOTES:
1. SPLICE LENGTHS ARE FOR MEMBERS THAT ARE NOT PART OF THE SFRS. REFERENCE PLANS AND ELEVATIONS FOR LAP SPLICES LENGTHS
AT SFRS ELEMENTS.
2. SPLICE LENGTHS APPLY TO ASTM A615 OR ASTM A706 GRADE 60 DEFORMED REINFORCING BARS ONLY.
3. SPLICE LENGTHS ARE BASED ON THE CLEAR COVER AND MINIMUM BAR CLEAR SPACING INDICATED BELOW.
4. SPLICE LENGTHS APPLY TO NORMAL WEIGHT CONCRETE ONLY. MULTIPLY TABLE VALUES BY 1.3 FOR LIGHT-WEIGHT CONCRETE.
5. SPLICE LENGTHS APPLY TO UNCOATED BARS ONLY. MULTIPLY TABLE VALUES BY 1.5 FOR EPOXY-COATED BARS.
6. COMBINATIONS OF EFFECTS DUE TO CONCRETE STRENGTH, CONCRETE WEIGHT, AND EPOXY COATING ARE CUMULATIVE.
7. SLAB, FOUNDATION AND MAT TOP BARS ARE BARS CAST ABOVE MORE THAN 12" OF FRESH CONCRETE. ALL OTHER SLAB BARS MAY BE
CONSIDERED BOTTOM BARS.
REINFORCING STEEL SHALL HAVE PROTECTION AND SPACING AS FOLLOWS:
CONCRETE COVER
USE CLEAR COVER MIN. CLEAR SPACING
CONCRETE CAST AGAINST AND EXPOSED TO EARTH 3" 3db OR 1"
ALL OTHER CONCRETE 2" 3db OR 1"
10 20 300-10-20-30
60" DEEP TRUSS FROM
TOP OF DECK
18" TOP OF DECK TO
BOTTOM OF STRUCTURE
CONCRETE FOOTING
TYP. EACH END OF BRIDGE
1/4"=1'-0"1 PLAN
1/4"=1'-0"2 ELEVATION
APPROXIMATE
EXISTING GRADE
-40
42" HIGH PEDESTRIAN RAIL
S5.01
'-0
" I N
SI
D
E
FA
C E
O F
R
AI
L
TO
IN
SI
D E
FA
C
E O
F R
AI
L
55'-0' CL BEARING TO CL BEARING CONTRACTOR DESIGNED,
STEEL FRAMED PEDESTRIAN BRIDGE
CL. BRIDGE
CONCRETE END PANEL
CONCRETE END PANEL
WING WALL
WING WALL
BOTTOM OF THE
FOOTING EL. 371.5
TOP OF PATHWAY
EL. 379
TOP OF PATHWAY
EL. 379
BOTTOM OF THE FOOTING
EL. 371.5
S5.02
S5.01
CL ABUTMENT 1
S6.01
CL ABUTMENT 2
S5.02
WING WALL
WING WALL
REF. S5.01
2' -0
M
IN
S6.01
REF. S5.01
1' -0
" M
IN
C
LE
AR
AN
C
E U
N D
ER
BR
ID
D
G E
TYP.
TYP.
NOTE:
REF. LANDSCAPE DRAWINGS FOR
BRIDGE LOCATION.
AS NOTED
K:\2022\10022200439\Drafting\10022200439_S2-01.dwg Anthony Do 9/25/2023 2:52 PM
DateRev. # By
SA
N
TA
C
LA
R
A C
O M
M U
N
IT
Y
PA
R K
- P H
AS
E
I
10022200439
09/29/2023DATE:
SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT #:
AT
AD
SF
SCALE
1 INCH = 50 FEET
50 100
111 SW Fifth Ave., Suite 2600 Portland, OR 97204
O: 503.227.3251 F: 503.227.7980 www.kpff.com
PLAN AND
ELEVATION
S2.01
1 1/2"=1'-0"1 SECTION AT ABUTMENT
1 1/2"=1'-0"2 DETAIL
1' -6
8"
#4 @ 6" o.c. 90°
HOOK STAND
#6 HORIZ.8"
#4 @ 12" o.c.
STIRRUPS
#4 @ 6" o.c.
1' -0
S5.01
S5.02
#4 @ 6" o.c.
90° HOOK EACH END
#4 @ 12" o.c. HORIZ.
EACH WAY
#4 @ 6" o.c. HORIZ. w/
90° HOOK EACH END
ABOVE BRIDGE DECK
#8 @ 12" o.c.
#4 @ 6" o.c.
4" 4"
2 MAX.
EXTEND OF
CRUSHED ROCK
#4 @ 6" o.c. 90° HOOK
EACH END
#4 @ 12" o.c. 90° HOOK
EACH END
2'-3"
4'-0"3'-0"
9"9"
2'-3"
1' -6
4'
-6
1' -6
FINISH GRADE
90° HOOK EACH END
#4 @ 12" o.c. TYP.
PROVIDE 3/4" CHAMFER
ON ALL EXPOSED
CORNERS TYP.
#4 @ 6" o.c. w/
90° HOOK
1'-0"
1/4" GAP AND FILL
FLEXIBLE SEALANT
8'-0"
3" C
O
VE
R
TY
P.
LA
P
SP
LI
C E
LE
N
G
TH
TY
P.
NATIVE UNDISTRIBUTED
MATERIAL
FILL SIDECREEK SIDE
3" M
IN
C O
VE
R
BRIDGE FINISH
ANCHORS BY BRIDGE
MANUFACTURER
L
C BENT &
WASHER AND DOUBLE
NUTS, TYP. BY
PEDESTRIAN BRIDGE
MANUFACTURER
L
CONCRETE DECK
C BEARING
ABUTMENT
BACKWALL
END VERT. OF TRUSS BY
PEDESTRIAN BRIDGE
MANUFACTURER
BASE PLATE BY
PEDESTRIAN BRIDGE
MANUFACTURER
SETTING PLATE BY
PEDESTRIAN BRIDGE
MANUFACTURER
BOND BREAKER ROD
PROVIDE 316" TO 14"
CHAMFER
NOTE:
CONTRACTOR TO
COORDINATE BASE
PLATE AND SETTING
PLATE TYPE, SIZE AND
LOCATION WITH
PEDESTRIAN BRIDGE
MANUFACTURER.
1/2" GAP. PROVIDE
NON-SLIP DIAMOND
PLATE BY BRIDGE
MANUFACTURER
ANCHOR ROD, TYP.
BY PEDESTRIAN
BRIDGE
MANUFACTURER
1 1/2"=1'-0"3 ANCHOR ROD DETAIL
5"
6" TO
CL. POST
6" TO
CL. POST
GUARDRAIL
POST GUARDRAIL
POST
NON-SHRINK
GROUT, TYP.
5"
CRUSHED ROCK MAX. 1 1/2"
WITH LESS THAN 5% PASSING
U.S. NO. 200 SIEVE PLACE IN
MAX. 95% OF MAX. DRY
DENSITY PER ASTM D7557
POURED JOINT SEAL
BRIDGE, ANCHOR BOLTS
AND CONNECTION TO
ABUTMENT BY BRIDGE
MANUFACTURER
AS NOTED
K:\2022\10022200439\Drafting\10022200439_S5-01.dwg Anthony Do 9/25/2023 2:52 PM
DateRev. # By
SA
N
TA
C
LA
R
A C
O M
M U
N
IT
Y
PA
R K
- P H
AS
E
I
10022200439
09/29/2023DATE:
SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT #:
AT
AD
SF
111 SW Fifth Ave., Suite 2600 Portland, OR 97204
O: 503.227.3251 F: 503.227.7980 www.kpff.com
FOUNDATION
DETAILS
S5.01
6"
TYP.
4" 4"
1"=1'-0"2 TYP. WING WALL SECTION
4" MIN. CRUSHED ROCK
MAX. 1 1/2" w/ LESS THAN
5% PASSING U.S. NO. AND
COMPACT TO MIN. 95% OF
MAX. DRY DENSITY PER
ASTM D1557
FINISH GRADE
#4 @ 6" o.c.
#4 @ 6" o.c. HORIZ.
FILL SIDE CREEK SIDE
GRANULAR
STRUCTURAL
BACKFILL
1'-9"1'-9"
BRIDGE
CL.
CL. BEARING
3"
COVER
TYP.
8' -0
8'
-0
PROVIDE 3/4" CHAMFER AT
ALL EXPOSED CORNERS
MIDDLE OF POSTS
AT EACH END TYP.
1"=1'-0"1 ABUTMENT PLAN VIEW
6"
TO CL. OF
POST
9" 2'-3"
TYP.
FILL SIDE CREEK SIDE
S6.01
6"
TO CL.
OF POST
TYP.
FOUNDATION
LINE
S5.02
S5.01
CL OF RAILING POST
SHOULD BE ON CL OF
THE BRIDGE RAILING
POSTS
CL OF RAILING POST
SHOULD BE ON CL OF
THE BRIDGE RAILING
POSTS
6' -0
6'
-0
2" 2"
8'-0"
TYP.
8'-0"
AS NOTED
K:\2022\10022200439\Drafting\10022200439_S5-02.dwg Anthony Do 9/25/2023 2:52 PM
DateRev. # By
SA
N
TA
C
LA
R
A C
O M
M U
N
IT
Y
PA
R K
- P H
AS
E
I
10022200439
09/29/2023DATE:
SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT #:
AT
AD
SF
111 SW Fifth Ave., Suite 2600 Portland, OR 97204
O: 503.227.3251 F: 503.227.7980 www.kpff.com
FOUNDATION
DETAILS
S5.02
6'-0" 6'-0"
CL BRIDGE
CL UTILITY
4' -0
#5 @ 1'-0" o.c.
EACH WAY
CL PROFILE GRADE,
WATER LINE,
AND PIVOT POINT
1' -4
M
AX
KICK PL
1 12%1 12%
4" M
AX
C
LR
. T
YP
5"
1" TY
P.
STAY-IN-PLACE METAL
DECKING SHALL BE
DESIGNED BY PEDESTRIAN
BRIDGE DESIGNER
4" CONT. BENT PL, TYP.
EACH SIDE OF DECK BY
PEDESTRIAN BRIDGE
DESIGNER
CONCRETE DECK DESIGN
BY KPFF (EOR) REF.
GENERAL STRUCTURAL
NOTES FOR BASIS OF
DESIGN
FOR TRUSS AESTHETICS,
REF SPECIAL PROVISION
00561.
21 2"
4" CAP PL TYP.
3"
TYP.
1" C
LR
2" D
EC
KI
N G
AS
SU
M
ED
, T O
BE
D
ES
IG
N
ED
BY
B
R
ID
G E
M
FR
INTERMEDIATE STEEL
SAFETY RAIL
1"=1'-0"1 TYPICAL BRIDGE SECTION
2"Øx3" WELDED HEADED
STUDS @ 4'-0" o.c. TYP.
2" Ø VENTS
2" Ø VENTS
RAIL POST
TYP.
INTERMEDIATE RAIL TYP.
@ 4" O.C. TO MATCH
AESTHETICS AND GEOMETRY
OF BRIDGE INTERMEDIATE
STEEL SAFETY RAIL.
COORDINATE w/ BRIDGE
MANUFACTURER.
REF. PROJECT PLANS FOR SPECIAL
PANEL AS REQUIRED AT BRIDGE ENDS
4'-0" MAX. 1'-0"
MAX.
4"
4' -0
1"=1'-0"2 ELEVATION OF RAILING
S6.01
S6.01
4" MAXIMUM GAP
TO BRIDGE RAIL
1'-0"
MAX. TYP.
BRIDGE RAIL
S6.01
S6.01
SPLICE TOP AND BOTTOM
RAILS AT LOCATION TO
FROM TYPICAL PANEL
(REF. DETAIL 4/S6.01)
S6.01
RAILING SHALL BE DESIGNED BY THE
PEDESTRIAN BRIDGE DESIGNER AND
SHALL CONFORM TO THE STRENGTH
AND GEOMETRIC REQUIREMENTS PER
AASHTO GUIDE SPEC. FOR PEDESTRIAN
BRIDGES.
TYP. EA.
SIDE &
OUTSIDE
CORNER
RAIL POST
HORIZONTAL RAIL
(2 REQUIRED PER POST)
8" Ø HOLE
2"R., TYP.
PL1
GENERAL NOTES
1. PROVIDE RECTANGULAR STRUCTURAL STEEL TUBING ACCORDING TO ASTM A847.
2. PROVIDE HSS 21
2 x 11
2 x 14 FOR ANCHOR POST.
3. PROVIDE HSS 21
2 x 1 x 0.083 (14 GAUGE) OR HSS 21
2 x 1 x 0.125 (11 GAUGE) FOR HORIZONTAL
TOP AND BOTTOM RAILS AND TERMINAL END VERTICALS.
4. PROVIDE ALL OTHER STRUCTURAL STEEL CONFORMING TO AASHTO M222 (ASTM A588).
5. WELDING ELECTRODES TO BE USED ON WEATHERING STEEL SHALL HAVE THE CHEMISTRY AND
WEATHERING PROPERTIES TO PROVIDE UNIFORM APPEARANCE AND WEATHERING
PERFORMANCE WITH WEATHERING BASE MATERIAL.
6. CONSTRUCT RAILING CONFORMING TO THE HORIZONTAL AND VERTICAL ALIGNMENT OF THE
STRUCTURE.
7. INSTALL POSTS NORMAL TO GRADE IN THE LONGITUDINAL DIRECTION AND VERTICAL IN THE
TRANSVERSE DIRECTION.
8. PROVIDE CONTINUOUS TOP HORIZONTAL RAIL ELEMENTS OVER A MINIMUM OF TWO POSTS
UNLESS SHOWN OTHERWISE ON DETAIL PLANS. PROVIDE A MINIMUM OF TWO ANCHOR POSTS
PER RAIL PANEL.
9. AFTER FABRICATION, EXPOSE RAIL TO ELEMENTS TO UNIFORMLY MAXIMIZE ESTABLISHMENT
OF CONSISTENT PATINA PRIOR TO INSTALLATION.
2" NORMAL
4" Ø VENT IN PL 316
PL 5 8X 21
8X 6" LONG STEEL BAR FOR
HSS21
2X 1X 0.125 RAILS OR PL 11
16X
16X 6" LONG STEEL BAR FOR HSS21
2X
1X 0.083 RAIL INCREASE LENGTH OF
BAR TO 8" AT EXPANSION JOINTS.
16" Ø x 12" DEEP HOLE FOR 316" Ø x 5 8"
LONG STAINLESS STEEL ROLL PIN.
INSTALL BAR PIN SIDE DOWN BOTH RAILS
(CENTER PIN BOTH WAYS ON BAR).
2" Ø VENT
2" Ø VENT1
2" Ø VENT
(2" MAX. AT EXP. JTS.
REF. BRIDGE PLANS)
AT RAIL END: MITER JOINTS
TOP & BOTTOM RAIL MEMBERS.
WELD & GRIND SMOOTH.
2"
6" FOR 6" BAR
(4" FOR 8" BAR)
PL 5 8 x 21 8 x 6" LONG STEEL BAR
FOR HSS 21
2 x 1x 0.125 RAILS OR
PL 11
16 x 23
16 x 6" LONG STEEL BAR
FOR HSS 21
2 x 1 x 0.083 RAIL
INCREASE LENGTH OF BAR TO 8" AT
EXPANSION JOINTS.
2"
5"
2"
21 4"
4"
INTERMEDIATE RAIL TO MATCH
AESTHETICS AND GEOMETRY OF
BRIDGE INTERMEDIATE STEEL
SAFETY RAIL COORDINATE w/
BRIDGE MANUFACTURER
3"=1'-0"3 RAIL POST WELD
G
3"=1'-0"4 RAIL SPLICE
G
3"=1'-0"5 INTERMEDIATE RAIL WELD
G
3"=1'-0"6 CORNER DETAIL
3"=1'-0"7 DETAIL
2" Ø VENT
3"=1'-0"8 PLATE WASHER
AS NOTED
K:\2022\10022200439\Drafting\10022200439_S6-01.dwg Anthony Do 9/25/2023 2:52 PM
DateRev. # By
SA
N
TA
C
LA
R
A C
O M
M U
N
IT
Y
PA
R K
- P H
AS
E
I
10022200439
09/29/2023DATE:
SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT #:
AT
AD
SF
111 SW Fifth Ave., Suite 2600 Portland, OR 97204
O: 503.227.3251 F: 503.227.7980 www.kpff.com
BRIDGE DETAILS
S6.01
P:\2022\22013 Santa Clara Community Park\10 Drawings\CAD\22013_E0.01.dwg Walker Frank 9/28/2023 2:14 PM
DateRev. # By
SA
N
TA
C
LA
R
A C
O M
M U
N
IT
Y
PA
R K
- P H
AS
E
I
915572
09/29/2023DATE:
SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT #:
WWF
WWF
RLH
ENGINEERING
REYES
PASSION CREATIVITY
SUSTAINABILITY
OREGON
100615PE
E0.01
ABBREVIATIONS,
LEGENDS, &
LUMINAIRE
SCHEDULE
NTS
Know what's below.
before you dig.Call
R
ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center.
Those rules are set forth in OAR 952-001-0010 through OAR 952-00-0090. You may obtain copies of these rules from the Center by calling (503) 232-1987. If you have any questions about these rules, you may contact the call Center.
AutoCAD SHX Text M
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text
OS
AutoCAD SHX Text
EMERGENCY GENERATOR
AutoCAD SHX Text G
AutoCAD SHX Text A
AutoCAD SHX Text
VOLT METER, AMP METER
AutoCAD SHX Text V
AutoCAD SHX Text
GROUND ROD
AutoCAD SHX Text T
AutoCAD SHX Text
DESIGNATES LUMINAIRE TYPE (SEE LUMINAIRE SCHEDULE)
AutoCAD SHX Text
INGRADE WALLWASH LUMINAIRE
AutoCAD SHX Text
OCCUPANCY SENSOR: INFRARED, ULTRASONIC.
AutoCAD SHX Text
TRANSFER SWITCH
AutoCAD SHX Text
XFSW
AutoCAD SHX Text
KILOVOLT AMP
AutoCAD SHX Text
KVA
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
AMPERE (AMP)
AutoCAD SHX Text
CIRCUIT BREAKER
AutoCAD SHX Text
CURRENT TRANSFORMER
AutoCAD SHX Text
ARCHITECT / ARCHITECTURAL
AutoCAD SHX Text
AUTOMATIC TRANSFER SWITCH
AutoCAD SHX Text
CLOSED CIRCUIT TELEVISION
AutoCAD SHX Text
EMERGENCY
AutoCAD SHX Text
EXPLOSION PROOF
AutoCAD SHX Text
EMERGENCY POWER OFF
AutoCAD SHX Text
ELECTRIC WATER COOLER
AutoCAD SHX Text
FIRE ALARM
AutoCAD SHX Text
FULL LOAD AMPS
AutoCAD SHX Text
FLUORESCENT
AutoCAD SHX Text
ELECTRIC METALLIC TUBING
AutoCAD SHX Text
ALTERNATE
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
CIRCUIT
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
KILOWATT HOUR
AutoCAD SHX Text
KILOWATT
AutoCAD SHX Text
KILOVOLT
AutoCAD SHX Text
GROUND FAULT INTERRUPTER
AutoCAD SHX Text
GROUND FAULT CIRCUIT INTERRUPTER
AutoCAD SHX Text
GALVANIZED RIGID CONDUIT
AutoCAD SHX Text
HORSEPOWER
AutoCAD SHX Text
HIGH PRESSURE SODIUM
AutoCAD SHX Text
HIGH VOLTAGE
AutoCAD SHX Text
ISOLATED GROUND
AutoCAD SHX Text
HERTZ
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
ATS
AutoCAD SHX Text
HP
AutoCAD SHX Text
KW
AutoCAD SHX Text
KWH
AutoCAD SHX Text
KV
AutoCAD SHX Text
HV
AutoCAD SHX Text
HZ
AutoCAD SHX Text
IG
AutoCAD SHX Text
HPS
AutoCAD SHX Text
GFCI
AutoCAD SHX Text
GRC
AutoCAD SHX Text
GRD
AutoCAD SHX Text
GFI
AutoCAD SHX Text
FLUOR
AutoCAD SHX Text
FA
AutoCAD SHX Text
FLA
AutoCAD SHX Text
EP
AutoCAD SHX Text
EPO
AutoCAD SHX Text
EWC
AutoCAD SHX Text
EMERG
AutoCAD SHX Text
EMT
AutoCAD SHX Text
CLG
AutoCAD SHX Text
DN
AutoCAD SHX Text
CT
AutoCAD SHX Text
CCTV
AutoCAD SHX Text
CKT
AutoCAD SHX Text
CB
AutoCAD SHX Text C
AutoCAD SHX Text
ALT
AutoCAD SHX Text
ARCH
AutoCAD SHX Text
AFF
AutoCAD SHX Text A
AutoCAD SHX Text
POLYVINYL CHLORIDE CONDUIT
AutoCAD SHX Text
TELEPHONE TERMINAL BOARD
AutoCAD SHX Text
UNINTERRUPTIBLE POWER SUPPLY
AutoCAD SHX Text
TRANSIENT VOLTAGE SURGE SUPPRESSION
AutoCAD SHX Text
TELEPHONE TERMINAL CABINET
AutoCAD SHX Text
VAPOR PROOF
AutoCAD SHX Text
WEATHER PROOF
AutoCAD SHX Text
TRANSFORMER
AutoCAD SHX Text
UNDERGROUND
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
VOLT AMPERES
AutoCAD SHX Text
VOLTAGE
AutoCAD SHX Text
WP
AutoCAD SHX Text
XFMR
AutoCAD SHX Text
VP
AutoCAD SHX Text W
AutoCAD SHX Text
WATTS
AutoCAD SHX Text
UPS
AutoCAD SHX Text
VA
AutoCAD SHX Text V
AutoCAD SHX Text
UG
AutoCAD SHX Text
TYP
AutoCAD SHX Text
SOLENOID VALVE
AutoCAD SHX Text
STARTER
AutoCAD SHX Text
TAMPERPROOF
AutoCAD SHX Text
TVSS
AutoCAD SHX Text
TTC
AutoCAD SHX Text
TTB
AutoCAD SHX Text
SW
AutoCAD SHX Text
TP
AutoCAD SHX Text
SV
AutoCAD SHX Text
STR
AutoCAD SHX Text
SWITCH
AutoCAD SHX Text
PANELBOARD
AutoCAD SHX Text
SUB-DISTRIBUTION PANEL
AutoCAD SHX Text
PUBLIC ADDRESS
AutoCAD SHX Text
POWER FACTOR
AutoCAD SHX Text
PHOTO ELECTRIC CELL
AutoCAD SHX Text
NIGHT LIGHT CIRCUIT
AutoCAD SHX Text
PF
AutoCAD SHX Text
PWR
AutoCAD SHX Text
SDP
AutoCAD SHX Text
PNL
AutoCAD SHX Text
PVC
AutoCAD SHX Text
POWER
AutoCAD SHX Text
PA
AutoCAD SHX Text
PE
AutoCAD SHX Text
NL
AutoCAD SHX Text
MAIN LUGS ONLY
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
MANUAL TRANSFER SWITCH
AutoCAD SHX Text
MAIN DISTRIBUTION PANEL
AutoCAD SHX Text
MINIMUM CIRCUIT AMPS
AutoCAD SHX Text
MAIN CIRCUIT BREAKER
AutoCAD SHX Text
MOTOR CONTROL CENTER
AutoCAD SHX Text
MECH
AutoCAD SHX Text
MTS
AutoCAD SHX Text
MLO
AutoCAD SHX Text
MDP
AutoCAD SHX Text
MCC
AutoCAD SHX Text
MCB
AutoCAD SHX Text
MCA
AutoCAD SHX Text
%%UA
AutoCAD SHX Text U
AutoCAD SHX Text
AutoCAD SHX Text
SWITCH: MANUAL MOTOR SWITCH WITH THERMAL OVERLOAD
AutoCAD SHX Text
WALL SWITCH: 1 POLE, 2 POLE
AutoCAD SHX Text
WALL SWITCH: KEY LOCK, MOMENTARY
AutoCAD SHX Text
WALL SWITCH: 3 WAY, 4 WAY
AutoCAD SHX Text
WALL SWITCH: LOW VOLTAGE, PILOT
AutoCAD SHX Text
POLE MOUNTED LUMINAIRE
AutoCAD SHX Text
MASTER ANTENNA TELEVISION
AutoCAD SHX Text
LIGHTNING ARRESTOR
AutoCAD SHX Text
LIGHTING
AutoCAD SHX Text
LOW VOLTAGE
AutoCAD SHX Text
KILOVOLT AMPS REACTIVE
AutoCAD SHX Text
LTG
AutoCAD SHX Text
LV
AutoCAD SHX Text
MATV
AutoCAD SHX Text
LA
AutoCAD SHX Text
KVAR
AutoCAD SHX Text
CONDUIT ELL: UP, DN.
AutoCAD SHX Text
HOME RUN DESTINATION SHOWN
AutoCAD SHX Text
CLOCK HANGER RECEPTACLE
AutoCAD SHX Text
CONTACTOR, RELAY, SOLENOID
AutoCAD SHX Text
PUSH BUTTON STATION
AutoCAD SHX Text
PEDESTAL OUTLET: POWER, SIGNAL, COMBINATION
AutoCAD SHX Text
SURFACE OUTLET STRIP: DIMENSION AS SHOWN
AutoCAD SHX Text
WIRING CONCEALED IN FLOOR OR UNDERGROUND
AutoCAD SHX Text
DISCONNECT SWITCH: FUSED, NON-FUSED
AutoCAD SHX Text
MOTOR STARTER: MAGNETIC, COMBINATION
AutoCAD SHX Text
WIRING CONCEALED IN CEILING OR WALL
AutoCAD SHX Text
TELEPOWER POLE, POWER, COMBINATION
AutoCAD SHX Text
FLUSH IN-FLOOR OUTLET: DUPLEX, COMBINATION, SIGNAL
AutoCAD SHX Text
SPECIAL PURPOSE OUTLET AS NOTED, EMERGENCY
AutoCAD SHX Text
MOTOR CONNECTION
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text
JUNCTION BOX
AutoCAD SHX Text
CEILING RECEPTACLE: DUPLEX
AutoCAD SHX Text
DENOTES RECEPTACLE ABOVE COUNTER
AutoCAD SHX Text
WALL RECEPTACLE: SINGLE, DUPLEX, EMERGENCY, 4-PLEX
AutoCAD SHX Text
WALL RECEPTACLE: EMERGENCY, 4-PLEX
AutoCAD SHX Text
SHEET NOTE
AutoCAD SHX Text
EXISTING TO BE RELOCATED
AutoCAD SHX Text
NEW
AutoCAD SHX Text
EXISTING TO REMAIN
AutoCAD SHX Text
EQUIPMENT DESIGNATOR SEE SCHEDULE.
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text S
AutoCAD SHX Text Y
AutoCAD SHX Text M
AutoCAD SHX Text B
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text S
AutoCAD SHX Text
EXISTING TO BE REMOVED
AutoCAD SHX Text P
AutoCAD SHX Text O
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
XXXX
AutoCAD SHX Text T
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text M
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text Q
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text
CIRCUIT BREAKER
AutoCAD SHX Text
BUSS
AutoCAD SHX Text
METER
AutoCAD SHX Text
AUTOMATIC SWITCH
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
FEEDER CALLOUT
AutoCAD SHX Text
SWITCH, FUSED SWITCH
AutoCAD SHX Text
TRANSFORMER
AutoCAD SHX Text
EQUIPMENT WITH GROUND
AutoCAD SHX Text
ELECTRICAL EQUIPMENT
AutoCAD SHX Text
CABINET: SURFACE, RECESSED
AutoCAD SHX Text
PANELBOARD: SURFACE, RECESSED
AutoCAD SHX Text
CURRENT TRANSFORMER
AutoCAD SHX Text
CABLE TRAY
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text
ASD
AutoCAD SHX Text F
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text X
AutoCAD SHX Text R
AutoCAD SHX Text N
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
OS
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text K
AutoCAD SHX Text S
AutoCAD SHX Text K
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text S
AutoCAD SHX Text
LV
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
OL
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
FSD
AutoCAD SHX Text
FIRE SMOKE DAMPER
AutoCAD SHX Text P
AutoCAD SHX Text
PULL BOX
AutoCAD SHX Text S
AutoCAD SHX Text
PULL BOX
AutoCAD SHX Text V
AutoCAD SHX Text
VAULT
AutoCAD SHX Text
%%USHEET INDEX
AutoCAD SHX Text
ABBREVIATIONS, LEGENDS, & LUMINAIRE SCHEDULE
AutoCAD SHX Text E0.01
AutoCAD SHX Text E1.01
AutoCAD SHX Text
ONE-LINE DIAGRAM AND SCHEDULES
AutoCAD SHX Text E2.01
AutoCAD SHX Text
RECESSED WALL MOUNTED WALLWASH LUMINAIRE
AutoCAD SHX Text
LED LINEAR CHANNEL LUMINAIRE
AutoCAD SHX Text
AC
AutoCAD SHX Text
IRRIGATION CONTROLLER
AutoCAD SHX Text Y
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text
NEW
AutoCAD SHX Text
UNDERGROUND CONDUIT
AutoCAD SHX Text
ELECTRICAL SITE PLAN
AutoCAD SHX Text THIS IS A STANDARD LEGEND SHEET, SOME SYMBOLS MAY APPEAR ON THIS SHEET THAT DO NOT APPEAR ON THE DRAWINGS.
AutoCAD SHX Text
BID
AutoCAD SHX Text
SET
AutoCAD SHX Text
ELECTRICAL DETAILS
AutoCAD SHX Text E3.01
AutoCAD SHX Text *A LIGHTING CUTSHEET PACKAGE WILL BE SUPPLIED AS A SEPARATE PART OF BID DOCUMENTS.
RIVER LOOP 2
MADISON MIDDLE SCHOOL
RIVER LOOP 2
SCALE:
SITE PLAN - ELECTRICAL
1/64"= 1'
P:\2022\22013 Santa Clara Community Park\10 Drawings\CAD\22013_E1.01.dwg Walker Frank 9/28/2023 2:15 PM
DateRev. # By
SA
N
TA
C
LA
R
A C
O M
M U
N
IT
Y
PA
R K
- P H
AS
E
I
915572
09/29/2023DATE:
SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT #:
WWF
WWF
RLH
ENGINEERING
REYES
PASSION CREATIVITY
SUSTAINABILITY
OREGON
100615PE
E1.01
ELECTRICAL SITE
PLAN
1/64" = 1'
SCALE:
ENLARGED SITE PLAN - ELECTRICAL
1/64"= 1'
AutoCAD SHX Text Xref .\Xrefs\X_Ross_Rec\PLAYGROUND.dwg
AutoCAD SHX Text P01C
AutoCAD SHX Text P01D
AutoCAD SHX Text P01C
AutoCAD SHX Text
SPRAY PLAY CONTROLLER. CONTROL PANEL LOCATED IN RESTROOM BUILDING.
AutoCAD SHX Text
EXISTING EWEB UTILITY POLE '#1086 45 1987'
AutoCAD SHX Text
NEW EWEB POLE MOUNTED 12KV-120/240V 25KVA TRANSFORMER
AutoCAD SHX Text PANEL 2NR1 AND LOCATION OF LIGHTING CONTROL NEMA 1 ENCLOSURE AND IRRIGATION CONTROLLER.
AutoCAD SHX Text
EWEB UTILITY METER MOUNTED ON EXTERIOR WALL OF BUILDING.
AutoCAD SHX Text M
AutoCAD SHX Text P02
AutoCAD SHX Text P02
AutoCAD SHX Text P02
AutoCAD SHX Text P02
AutoCAD SHX Text P01B
AutoCAD SHX Text P02
AutoCAD SHX Text P02
AutoCAD SHX Text P02
AutoCAD SHX Text P02
AutoCAD SHX Text P02
AutoCAD SHX Text P01D
AutoCAD SHX Text P01C
AutoCAD SHX Text
CONTRACTOR INSTALLED SECONDARY PULLBOX. SIZE PER EWEB REQUIREMENTS.
AutoCAD SHX Text
EXISTING MAINTENANCE BUILDING.
AutoCAD SHX Text J
AutoCAD SHX Text P01C
AutoCAD SHX Text P01D
AutoCAD SHX Text P01C
AutoCAD SHX Text P01C
AutoCAD SHX Text P01D
AutoCAD SHX Text P02
AutoCAD SHX Text
2NR1-35,37
AutoCAD SHX Text
2NR1-35,37
AutoCAD SHX Text
2NR1-35,37
AutoCAD SHX Text
2NR1-35,37
AutoCAD SHX Text
2NR1-35,37
AutoCAD SHX Text
2NR1-35,37
AutoCAD SHX Text
2NR1-35,37
AutoCAD SHX Text
2NR1-31,33
AutoCAD SHX Text
2NR1-31,33
AutoCAD SHX Text
2NR1-31,33
AutoCAD SHX Text
2NR1-31,33
AutoCAD SHX Text
2NR1-31,33
AutoCAD SHX Text
2NR1-31,33
AutoCAD SHX Text
2NR1-35,37
AutoCAD SHX Text P02
AutoCAD SHX Text
2NR1-29
AutoCAD SHX Text
CONTRACTOR INSTALLED SECONDARY PULLBOX. SIZE PER EWEB REQUIREMENTS.
AutoCAD SHX Text P02
AutoCAD SHX Text P02
AutoCAD SHX Text P02
AutoCAD SHX Text P02
AutoCAD SHX Text P02
AutoCAD SHX Text P02
AutoCAD SHX Text A. FOR ELECTRICAL LEGEND AND ABBREVIATIONS SEE DRAWING E0.01. FOR ELECTRICAL LEGEND AND ABBREVIATIONS SEE DRAWING E0.01. B. UNLESS OTHERWISE NOTED ALL UNDERGROUND LIGHTING CONDUITS UNLESS OTHERWISE NOTED ALL UNDERGROUND LIGHTING CONDUITS SHALL BE 1" PVC SCHEDULE 40 MINIMUM AND BE A MINIMUM OF 30" BELOW FINISH GRADE. LIGHTING CONDUITS ENTERING CONCRETE FOUNDATIONS SHALL BE 1" RIGID CONDUIT. COORDINATE ALL CONDUIT WITH OTHER UTILITIES AND TRADES. AVOID ROUTING THROUGH PLAYGROUND AREAS WHEN AT ALL POSSIBLE. C. UNLESS OTHERWISE NOTED PROVIDE (2) 8 AWG CU AND (1) 8 AWG CU UNLESS OTHERWISE NOTED PROVIDE (2) 8 AWG CU AND (1) 8 AWG CU GND FOR ALL SITE LIGHTING CIRCUITS. D. ROUTE ALL CONDUIT UNDER PAVED AREA UNLESS CONDUIT GOES ROUTE ALL CONDUIT UNDER PAVED AREA UNLESS CONDUIT GOES DIRECTLY TO GROUND MOUNTED DEVICE. E. SPLASH PAD ELECTRICAL CONNECTIONS AND GROUNDING SYSTEM SHALL SPLASH PAD ELECTRICAL CONNECTIONS AND GROUNDING SYSTEM SHALL MEET NEC ARTICLE 680. F. SEE LANDSCAPE ARCHITECTURAL DRAWINGS FOR ADDITIONAL SEE LANDSCAPE ARCHITECTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS AND EXACT LOCATIONS OF LUMINAIRES. G. SEE LANDSCAPE ARCHITECTURAL DRAWINGS FOR LIGHTING POLE BASE SEE LANDSCAPE ARCHITECTURAL DRAWINGS FOR LIGHTING POLE BASE DETAILS. H. PROVIDE GROUND ROD WITH BARE COPPER AND BOND TO GROUND PROVIDE GROUND ROD WITH BARE COPPER AND BOND TO GROUND TERMINAL AT EACH LIGHTING POLE. I. CONTRACTOR IS RESPONSIBLE FOR ALL SUBSTRUCTURE INSTALLATION, CONTRACTOR IS RESPONSIBLE FOR ALL SUBSTRUCTURE INSTALLATION, METERING EQUIPMENT, AND SERVICE LATERALS (TRENCHING, SECONDARY PULLBOX, ALL CONDUIT INCLUDING THE FIRST 10' OF THE SECONDARY DIP AND ELBOWS PER EWEB STANDARDS, SERVICE LATERAL CONDUIT, AND WIRE INSTALLATION). J. ALL ELECTRICAL EQUIPMENT SHALL REMAIN AT LEAST 3 INCHES ABOVE ALL ELECTRICAL EQUIPMENT SHALL REMAIN AT LEAST 3 INCHES ABOVE THE FLOOD ELEVATION AS SPECIFIED BY THE CIVIL DRAWINGS.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
KEY NOTES
AutoCAD SHX Text
BID
AutoCAD SHX Text
SET
AutoCAD SHX Text
AutoCAD SHX Text
1. PROVIDE ADEQUATELY SIZED LIGHT POLE JUNCTION BOX. JUNCTION BOX PROVIDE ADEQUATELY SIZED LIGHT POLE JUNCTION BOX. JUNCTION BOX SHALL BE NEMA 3R RATED AND LOCKABLE. SEE DETAIL 2/E3.01. 2. PROVIDE WORKING CLEARANCES FOR UTILITY METER GEAR PER EWEB PROVIDE WORKING CLEARANCES FOR UTILITY METER GEAR PER EWEB REQUIREMENTS. REFER TO ONE-LINE DIAGRAM FOR DETAILS. 3. SEE REFERENCED SHEET FOR RESTROOM BUILDING ELECTRICAL DESIGN. SEE REFERENCED SHEET FOR RESTROOM BUILDING ELECTRICAL DESIGN. 4. ELECTRICAL CONTRACTOR TO INTERCEPT EXISTING MAINTENANCE ELECTRICAL CONTRACTOR TO INTERCEPT EXISTING MAINTENANCE BUILDING RECEPTACLE AND LIGHTING CIRCUITS INTO NEW EXTERIOR BUILDING MOUNTED JUNCTION BOX. EXISTING CIRCUITS SHALL BE TIED TO NEW CIRCUITS FED OVERHEAD FROM NEW RESTROOM POWER PANEL. 5. PROVIDE 2" LIGHTING CONDUIT STUB OUT FOR FUTURE PARKING LOT PROVIDE 2" LIGHTING CONDUIT STUB OUT FOR FUTURE PARKING LOT DEVELOPMENT. 6. ARROW INDICATES LUMINAIRE AIM. TYPICAL FOR ALL SIMILAR. ARROW INDICATES LUMINAIRE AIM. TYPICAL FOR ALL SIMILAR. 7. COORDINATE WITH SHELTER STRUCTURE MANUFACTURER TO ROUTE COORDINATE WITH SHELTER STRUCTURE MANUFACTURER TO ROUTE LIGHTING CONDUIT/WIRING INTERNALLY THROUGH THE SHELTER STRUCTURE. 8. PROVIDE LIGHTCLOUD WIRELESS CONTROL SYSTEM TO CONTROL SHELTER PROVIDE LIGHTCLOUD WIRELESS CONTROL SYSTEM TO CONTROL SHELTER LIGHTING AND RECEPTACLES. COORDINATE WITH LIGHTCLOUD REPRESENTATIVE TO MOUNT LIGHTCLOUD CONTROLLER WITHIN THE LOCKABLE SPRAY PLAY CONTROLLER CABINET TO PROVIDE ENVIRONMENTAL PROTECTION. 9. CIRCUIT SPRAY PLAY CONTROLLER TO 2NR1-25. INSTALL PER CIRCUIT SPRAY PLAY CONTROLLER TO 2NR1-25. INSTALL PER MANUFACTURER'S REQUIREMENTS. 10. PULLBOX SHALL HAVE AN OPEN OR PERFORATED BOTTOM FILLED WITH PULLBOX SHALL HAVE AN OPEN OR PERFORATED BOTTOM FILLED WITH GRAVEL TO RESIST BUOYANCY DURING A FLOOD. CONFIRM PULLBOX LOCATION WITH EWEB PRIOR TO INSTALLATION.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SEE 2/E1.01 FOR CONTINUATION
AutoCAD SHX Text
SEE 1/E1.01 FOR CONTINUATION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
P:\2022\22013 Santa Clara Community Park\10 Drawings\CAD\22013_E2.01.dwg Walker Frank 9/28/2023 2:15 PM
DateRev. # By
SA
N
TA
C
LA
R
A C
O M
M U
N
IT
Y
PA
R K
- P H
AS
E
I
915572
09/29/2023DATE:
SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT #:
WWF
WWF
RLH
ENGINEERING
REYES
PASSION CREATIVITY
SUSTAINABILITY
OREGON
100615PE
E2.01
ONE-LINE DIAGRAM
AND SCHEDULES
NTS
AutoCAD SHX Text
2 #12 CU THWN, 1 #12 CU GRD IN 1/2"C.
AutoCAD SHX Text 20A-2
AutoCAD SHX Text
COPPER FEEDER SCHEDULE
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
LOAD SUMMARY
AutoCAD SHX Text
SHEET NOTES
AutoCAD SHX Text
AutoCAD SHX Text SEE RESTROOM BUILDING ELECTRICAL DRAWINGS FOR CIRCUITS CONTAINED INSIDE DASHED AREA.
AutoCAD SHX Text
1. FOR ELECTRICAL SYMBOLS LEGEND AND ABBREVIATIONS FOR ELECTRICAL SYMBOLS LEGEND AND ABBREVIATIONS SEE DRAWING E0.01.
AutoCAD SHX Text 400A-U
AutoCAD SHX Text E2.01
AutoCAD SHX Text
AutoCAD SHX Text
PANEL SCHEDULE
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text 400A-2
AutoCAD SHX Text
EMPTY 3"C PVC WITH PULL STRING (PER EWEB REQUIREMENTS)
AutoCAD SHX Text LOAD - 120/240V, 1PH, 3W, 400AMP BUS LIGHTING: 3.81 KVA 3.81 KVA KVA RECEPTACLES: 26.3 KVA 26.3 KVA KVA RESISTIVE LOADS: 32 KVA 32 KVA KVA MISC. LOADS: 3.5 KVA 3.5 KVA KVA TOTAL LOAD: 65.61 KVA65.61 KVAKVA
AutoCAD SHX Text
BID
AutoCAD SHX Text
SET
AutoCAD SHX Text M
AutoCAD SHX Text
GROUND RODS
AutoCAD SHX Text E2.01
AutoCAD SHX Text
AutoCAD SHX Text
ONE-LINE DIAGRAM
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
COLD
AutoCAD SHX Text
WATER
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
PANEL 2NR1
AutoCAD SHX Text 120/240V
AutoCAD SHX Text
SPD
AutoCAD SHX Text
LIGHTING
AutoCAD SHX Text
CONTROL
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
CONFIRM CONDUIT SIZE WITH EWEB BEFORE INSTALLATION
AutoCAD SHX Text
#3 BARE CU GROUND TO GROUND GRID
AutoCAD SHX Text
EXISTING EWEB POLE
AutoCAD SHX Text
PROVIDE EUSERC EWEB N3R UTILITY METER PER EWEB REQUIREMENTS
AutoCAD SHX Text T
AutoCAD SHX Text NEW EWEB POLE MOUNTED 12KV-120/240V 25KVA TRANSFORMER AVAILABLE FAULT CURRENT AT SECONDARY BUSHINGS OF TRANSFORMER: 9,180A
AutoCAD SHX Text
320A METER
AutoCAD SHX Text E2.01
AutoCAD SHX Text
AutoCAD SHX Text
LIGHTING CONTROL SCHEDULE
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text E2.01
AutoCAD SHX Text
AutoCAD SHX Text
VOLTAGE DROP CALCULATIONS
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text 20A-2
AutoCAD SHX Text 400A-2
AutoCAD SHX Text 400A-U
AutoCAD SHX Text
2 500KCMIL CU THWN-2, 1 #3 CU GRD IN 3"C.
FOUNDATION PLAN VIEW
12'
4' DEPTH
3" MIN.
CLEARANCE
(TYP.)
30" MIN. DIA.
TYPICAL FOOTING
LIGHT CONFIGURATION
KIM LIGHTING FIXTURE - RA172-36L-350-3K7-*-CLR-BC
· WHERE * IS THE LIGHTING PATTERN TYPE AS SHOWN ON
LIGHT FIXTURE SCHEDULE.
· PROVIDE 1 PHOTO CELL OPTION PER CIRCUIT.
POLE CONFIGURATION
KIM LIGHTING POLE - KRS-(12, 14, 16)-4120-PT-PT-BLS-BC-ABT
· POLE TO BE 11 GA. ROUND STEEL NON-TAPERED POLE.
· SEE PLANS OR SPECIAL PROVISIONS FOR POLE HEIGHT.
TOP 12" OF CONCRETE FOUNDATION SHALL
BE ROUND
ARM CONFIGURATION
KIM LIGHTING POST TOP SWEPT CAST ARM - HA03S-TM1/BL
1" RIGID CONDUIT
(IN FOUNDATION AND ELBOWS)
MANUFACTUER-SUPPLIED ANCHOR (J) BOLTS AND
HOLD DOWN/ LEVELING NUTS AND WASHERS. SIZE
VARIES BASED ON POLE HEIGHT
(8) #5 BARS
#4 HOOPS ON 12" CENTERS
COMMERCIAL GRADE CONCRETE
HAND HOLE, MIN 3" X 5", ENGINEERED-
TO-ORDER AT TOP OF POLE
GROUT BED
HOLD DOWN AND LEVELING NUTS
GROUND BUSHINGS
SIDEWALK OR CONCRETE PAD, SEE PLANS
WIRE, SIZE PER PLANS
GROUND LUG
FUSE HOLDER AND
MIN. 2 FT. SLACK IN WIRE
(REQUIRED)
"J" HOOK
CABLE GRIP
KIM LIGHTING
PROVIDED WIRE
LUMINAIRE
ARM
ED
G
E O
F
PA
TH
ORIENT LUMINAIRE ARM
PERPENDICULAR TO PATH OR AS
DIRECTED AT INTERSECTIONS
FOOTING
8-#5 VERTICAL
#4 HOOPS @ 12" SPACING
OVERLAP IF NOT WELDED.
(4) MANUFACTURER-SUPPLIED
ANCHOR (J) BOLTS AND HOLD
DOWN/ LEVELING NUTS AND
WASHERS. SIZE VARIES BASED
ON POLE HEIGHT.
NOTE:
1. DRAWING NOT TO SCALE, DIMENSIONS ± 1/2"
2. 5/8" DIA. X 8' GROUND ROD COPPERWELD WITH AN ACCESSIBLE
CLAMP SHALL BE INSTALLED IN THE FOUNDATION.
90°
MIN. 24" EXTRA WIRE
(AT EACH CONDUIT)
GROUND ROD
WIRE SPLICE
WIRE EXIT
SUPPLY WIRING
WIRING TO LIGHT
COMPACTED
SUBGRADE
LOCKABLE AND VANDAL RESISTANT
JUNCTION BOX. SEE TM472
GROUND LUG
AND WIRE
TS
COIL
N2NR1-27.
SPARE
2NR1-5.
2NR1-35,37.
2NR1-31,33. POLE LIGHTS
POLE LIGHTS
LIGHTING CONTACTOR
ELECTRICALLY HELD, 20A, 120V
CONTACTS.
TIME SWITCH, 24HR FORMAT
PROGRAMMABLE ELECTRONIC WITH
BATTERY BACKUP, 120V.
PROVIDE NEMA 1 LOCKABLE
ENCLOSURE WITH HINGED INNER
DOOR. BYPASS SWITCHES TO BE
MOUNTED ON INNER DOOR.
PROVIDE ENGINEERED LABEL.
SPARE
SPST 20A NEMA 3R
TOGGLE SWITCH
#10, 1" RGS
RESTROOM EXTERIOR
SPARE
P:\2022\22013 Santa Clara Community Park\10 Drawings\CAD\22013_E3.01.dwg Walker Frank 9/28/2023 2:15 PM
DateRev. # By
SA
N
TA
C
LA
R
A C
O M
M U
N
IT
Y
PA
R K
- P H
AS
E
I
915572
09/29/2023DATE:
SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT #:
WWF
WWF
RLH
ENGINEERING
REYES
PASSION CREATIVITY
SUSTAINABILITY
OREGON
100615PE
E3.01
ELECTRICAL
DETAILS
NTS
AutoCAD SHX Text E3.01
AutoCAD SHX Text
AutoCAD SHX Text
%%ULIGHT POLE AND FOOTING
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text E3.01
AutoCAD SHX Text
AutoCAD SHX Text
%%ULIGHTING JUNCTION BOX AND WIRE LAYOUT
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text E3.01
AutoCAD SHX Text
AutoCAD SHX Text
%%ULIGHTING CONTROL DIAGRAM
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
BID
SET
`Know what's below.
before you dig.Call
R
ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center.
Those rules are set forth in OAR 952-001-0010 through OAR 952-00-0090. You may obtain copies of these rules from the Center by calling (503) 232-1987. If you have any questions about these rules, you may contact the call Center.
W009
W326C-3
W326C-2
W326-1
W200
W071
W093
W280
W280
W280
W280
W280
W071
W006C
W200
CODE SUMMARY
CHAPTER 3 - USE & OCCUPANCY
OCCUPANCY: GROUP S-1
CHAPTER 5 - GENERAL BUILDING HEIGHTS & AREAS
ALLOWABLE STORIES: 1
ALLOWABLE SF PER STORY: 9,000 SF
PROPSED : 980 SF, 1 STORY
CHAPTER 6 TYPES OF CONSTRUCTION
CONSTRUCTION TYPE: 5B
FIRE SPRINKLERS: NS
FIRE ALARM SYSTEM: NS
CHAPTER 8 - INTERIOR FINISHES
CLASS 'C' INTERIOR FINISHES ALLOWABLE PER TABLE 803.13
CHAPTER 9 - FIRE PROTECTION SYSTEMS
PER 903 - NO AUTOMATIC FIRE SPRINKLER SYSTEM REQUIRED.
PROVIDE 2A10BC BRACKET MOUNT FIRE EXTINGUISHERS, MAX 48" AFF
CHAPTER 10 - MEANS OF EGRESS
OCCUPANCY COUNT: 2
MAX. COMMON PATH OF TRAVEL (1006.2.1): 100'
PROPOSED: 29'-0"
MAX. TRAVEL DISTANCE (1006.3.3(2)): 75'
PROPOSED: 40'-6"
SUMMARY OF WORK
NEW 980 SF RESTROOM, SERVICE, & STORAGE BUILDING. WORK
INCLUDES CONCRETE, FOUNDATION, CMU BLOCK, WOOD FRAMING,
WOOD ROOF, FINISHES, ELECTRICAL, PLUMBING, AND MECHANICAL.
CHAPTER 11 - ACCESSIBILITY AMENDMENT
NEW ITEMS MEET THE REQUIREMENTS OF THIS SECTION. ITEMS
ARE NEW AND IN COMPLIANCE.
CHAPTER 29 - PLUMBING SYSTEMS
BUILDING OCCUPANTS: 2
REQUIRED: 1 TOILET & 1 LAV
PROPOSED: 3 TOILETS & 3 LAVS
ASHRAE 90.1-2019 SUMMARY
CLIMATE ZONE 4C
NEW BUILDING THERMAL ENVELOPE COMPONENTS SHALL MEET
THE REQUIREMENTS OF A SEMI-HEATED BUILDING PER ASHRAE 90.1
WALLS (INSULATED WOOD FRAMED): MIN R-13
ROOF: MIN R-10 CONTINUOUS INSULATION ENTIRELY ABOVE DECK
SWINGING DOORS: U-0.370
A1.20
PARK DESIGN BY OTHERS
RIVER LOOP 2
EXISTING MAINTENANCE BUILDING
FIRE APPARATUS ACCESS
ROAD, 20'W
N | 904595.8607
E | 4233213.4126
N | 904557.3755
E | 4233233.3292
COORDINATE LOCATION OF BUILDING W/
LANDSCAPE PLANS
NEW WALL PARTITION, SEE WALL
TYPES THIS SHEET
DOOR, FRAME, & HARDWARE, SEE
ALSO DOOR SCHEDULE, SHEET
A5.21
1.
2.
3.
4.
GENERAL NOTES
DIMENSIONS TO FACE OF FINISH, UON - FIELD VERIFY,
REPORT DISCREPANCIES TO ARCH PRIOR TO WORK
CLEAN PARTITION CAVITIES PRIOR TO ENCLOSING
REFER TO MECHANICAL, ELECTRICAL, AND PLUMIBNG
DRAWINGS/SPECIFICATIONS FOR ADDITIONAL SCOPE OF
WORK
DO NOT SCALE DRAWINGS. COORDINATE DIMENSIONS
SHOWN ON DRAWINGS WITH ACTUAL FIELD
MEASUREMENTS. NOTIFY ARCHITECT OF DISCREPANCIES
LEGEND
OCCUPANCY SENSOROS
A
1X4 SURFACE MOUNT LIGHT FIXTURE
ELECTRICAL PANEL
± APPROXIMATELY
CENTERLINE
A
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
AL ALUMINUM
B
BD BOARD
C
CLR CLEAR
CONC CONCRETE
CONT CONTINUOUS
D
DBL DOUBLE
DIA DIAMETER
DIM DIMENSION
DS DOWNSPOUT
E
(E) EXISTING
EA EACH
ELEV ELEVATION
EP ELECTRICAL PANEL
EQ EQUAL
F
F.D. FLOOR DRAIN
FE FIRE EXTINGUISHER
FIN FINISH
FL FLOOR
FT FOOT OR FEET
G
GA GAUGE
GALV GALVANIZED
GYP GYPSUM
H
HDWE HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
ABBREVIATIONS
M
MAX MAXIMUM
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
N
(N) NEW
N.I.C. NOT IN CONTRACT
NTS NOT TO SCALE
O
OC ON CENTER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
P
PREFIN PREFINISHED
R
(R) RELOCATE
REQ REQUIRED
S
SIM SIMILAR
SM SHEET METAL
SQ SQUARE
STD STANDARD
T
TYP TYPICAL
V
VERT VERTICAL
V.I.F. VERIFY IN FIELD
W
W/ WITH
WD WOOD
W/O WITHOUT
WRB WEATHER RESISTANT BARRIER
CL
PROJECT CONTACTS
OWNER:
CITY OF EUGENE PUBLIC WORKS,
ENGINEERING DIVISION
24 E BROADWAY
EUGENE, OR 97401
TEL: (541) 682-5560
POC: MARINA WRENSCH
EMAIL: mwrensch@eugene-or.gov
ARCHITECT:
GMA ARCHITECTS
860 W. PARK STREET
EUGENE, OREGON 97401
TEL: 541.344.9157
PA: JOSEPH E MOORE, AIA
EMAIL: jmoore@gma-arch.com
PM: BAILEY BERNHEINE
EMAIL: bbernheine@gma-arch.com
STRUCTURAL:
MORTIER ANG ENGINEERS
1355 OAK ST., SUITE 200
EUGENE, OR 97401
TEL: (541) 484-9080
ATTN: JOK ANG, PE SE
EMAIL: joka@mortierang.com
MECHANICAL, ELECTRICAL, PLUMBING:
SYSTEMS WEST ENGINEERS
725 A ST.
SPRINGFIELD, OR 97477
TEL: (541) 342-7210
ATTN: NATE JENKINS, PE
EMAIL: njenkins@SystemsWestEngineers.com
SHEET INDEX
VICINITY MAP
NOT TO SCALE
RIVER LOOP 2
WILKES DR
R
IV
E R
L O
O P
W
IL
LA
M
ET
TE
R
IV
ER
MADISON MIDDLE SCHOOL
AREA OF WORK
COMMUNITY PARK NORTH
SITE - PHASE 01
NORTH
2x6 MIN. NOMINAL
PRESSURE TREATED WOOD
STUDS @16" OC
R-21 UNFACED FIBERGLASS
BATT INSULATION, TYP UON
VAPOR RETARDER
5/8" TYPE 'X' MMR GYPSUM
BOARD
WALL TYPE A
A
WALL TYPE B
B
WALL TYPE C
C
5/8" TYPE 'X' MMR GYPSUM
BOARD
WALL TYPE D
D
15/32" APA RATED SHEATHING.
ATTACH W/ .131" DIA x 2-1/2" NAILS
@ 6" OC PANEL EDGES & @ 12" OC
FIELD, BLOCK PANEL EDGES AS REQ'D
WEATHER BARRIER, TYP
HORIZONTAL FIBER CEMENT BOARD
SIDING
2x6 PT SILL ATTACHED TO TOP OF
CMU WALLS W/5/8" DIA. AB @ 32"
OC W/ 12" MIN. EMBED
8" CMU WALL, SEE
ALSO STRUCTURAL
CMU TO BE FULLY
GROUTED W/
SMOOTH FACE, TYP
UON
SEE WALL SECTIONS
& DETAILS FOR
BELOW GRADE REQ'S
SEE BLDG
SECTION
2x6 PT SILL PLATE
-FASTEN W/ .12"x3" MIN
POWDER ACTUADED FASTNER
@ 12" OC MAX
CONCRETE SLAB ON GRADE FLOOR
STRUCTURE
TOP PLATE AND BEVELED
TOP PLATE AS REQ'S FOR
ROOF SUPPORT
2x6 NOM WD DF-L#2 STUDS @ 24" OC
WALL TYPE F
F
5/8" TYPE 'X' MMR
GYPSUM BOARD
ALIGN FACE W/ CMU
WALL ASSY BELOW
ADJACENT WALL ASSEMBLY
5/8" TYPE 'X' MMR
GYPSUM BOARD
FUR AS REQ'D TO
ALIGN FACE/WALL W/
CMU WALL BELOW,
BOTH SIDES
ALIGN FACE W/ CMU
WALL ASSY BELOW
ALIGN FACE W/ CMU WALL ASSY
BELOW
A1 -6" WIDE CMU BLOCK IN LIEU OF 8"
-#5 VERTS @ 16" OC & (2) #4 HORIZ @ TOP & BTM OF
WALL & @ 48" OC MAX
ADJACENT WALL ASSEMBLY
OMIT GYPSUM BOARD B1
15/32" APA RATED SHEATHING.
ATTACH W/ .131" DIA x 2-1/2"
NAILS @ 6" OC PANEL EDGES &
@ 12" OC FIELD, BLOCK PANEL
EDGES AS REQ'D
D1 -OMIT PLYWD SHEATHING
-DBL PT SILL PLATE. OMIT ANCHOR BOLTS WHERE GLASS
BLOCK OPENING OCCURS BELOW SILL
TOP PLATE & BEVELED TOP PLATE AS
REQ'D
-SEE ALSO ROOF FRAMING PLAN AND
STRUCTURAL FOR DOUBLE TOP PLATE
REQ'S
TOP PLATE & BEVELED TOP
PLATE AS REQ'D
-SEE ALSO ROOF FRAMING
PLAN AND STRUCTURAL
FOR DOUBLE TOP PLATE
REQ'S
C1 -3/4" PLYWOOD IN LIEU OF GYPSUM BOARD
WOOD DECKING
-NAIL DECKING TO SUPPORTS USING .131" DIA x 3" NAILS @ 6" OC
VAPOR BARRIER
R-15 CONTINUOUS
RIGID INSULATION
WEATHER BARRIER
STANDING SEAM 24 GA. PRE-FIN METAL PANEL
ROOF ASSEMBLY - R1
R1
ROOF SHEATHING, SEE
ALSO STRUCTURAL
LIGHT STEEL TROWEL FINISH W/ CLEAR
CONCRETE FLOOR SEALANT THROUGHOUT
-SEE FLOOR PLAN FOR SLOPE
4" CONCRETE SLAB ON GRADE W/ #4 STEEL
REINFORCING @ 18" OC EACH WAY
15 MIL VAPOR BARRIER
STRUCTURAL FILL PER GEOTECH REPORT
SECTION 5.5
FLOOR ASSEMBLY - F1
F1
DIMENSION TO FACE OF FINISH,
FACE OF CONCRETE, GRID
LINE, OR AS NOTED.
DRAWING REVISION
DOOR TAG
CALLOUT
DRAWING NUMBER
DRAWING NUMBER
EXTERIOR ELEVATION
DOOR NUMBER -
REF DOOR SCH
SHEET NUMBER
KEYNOTE
BUILDING SECTION
SHEET NUMBER
ROOM TAG
INTERIOR ELEVATION
1"
A101
SIM
DRAWING NUMBER
SHEET NUMBER
ROOM NUMBER
Room name
SYMBOL LEGEND
A101
SIM
A3.00
A3.00
A WALL TAG
DATE:
BID
SET
SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT #:
Rev. # Date By
BIM 360://22452 Santa Clara Community Park Restrooms/22452 Santa Clara Community Park Restrooms_Phase 05.rvt9/29/2023 10:06:28 AM
As indicated
COVER
915572
S A
N T
A C
L A
R A
C O
M M
U N
IT
Y
P A
R K
P
H A
S E
I
9/29/2023
A0.01
JM
BB
JM
1" = 80'-0"1
OVERALL SITE PLAN
NORTH
GENERAL INFORMATION
A0.01 COVER
ARCHITECTURAL
A1.20 FOUNDATION & FLOOR PLANS
A1.40 RCP & ROOF PLANS
A2.10 INTERIOR ELEVATIONS
A3.10 ELEVATIONS
A4.10 SECTIONS
A5.20 DETAILS
A5.21 DETAILS
STRUCTURAL
S1.1 STRUCTURAL GENERAL NOTES
S1.2 STRUCTURAL GENERAL NOTES
S3.1 STRUCTURAL DETAILS
PLUMBING
P0.01 LEGEND, GENERAL NOTES & SHEET INDEX
P1.21 PLUMBING FLOOR PLAN
P5.01 DETAILS
MECHANICAL
M0.01 LEGEND, SCHEDULE, GENERAL NOTES &
SHEET INDEX
M1.21 MECHANICAL FLOOR PLAN
ELECTRICAL
E5.01 LEGEND, GENERAL NOTES & SHEET INDEX
E6.01 ELECTRICAL PLANS
E7.01 SCHEDULES
1 1/2" = 1'-0"4
WALL ASSEMBLIES
1 1/2" = 1'-0"3
ROOF ASSEMBLIES
1 1/2" = 1'-0"2
FLOOR ASSEMBLIES
FD
FD
A4.10
A4.10
A3.10
A3.10 4
A3.10
A3.102
43' - 4"
4' - 0" CLR 8' - 8" CLR
C
LR
FAMILY
RESTROOM
FAMILY
RESTROOM
FAMILY
RESTROOM
SERVICE
CORE
103REC
STORAGE
16' - 6"
105A
104A
104B
D1
F
B1
ABV
ABV
ABV
CLR
± 3' - 0"
C
LR
FE
FE
A 2.
SERVICE
CHASE
C
24 24
D
ABV
102A 101A
103A
4 44
B1
B
B1
ABV
ABV
ABV
D ABV
D1
ABV
A
D ABV
A D1
ABV
8' - 8" CLR9' - 4"8' - 8" CLR
1' - 4"
A2.10
1DED
TYP
18 18
11 11
DED
B1
ABV
A2.10
A2.10
TYP
2 2
W H
CC
C
CC
C
C1
A
A
A
A
A
A
A1
A
A
A1 A1
A1
SIM
A
A A1
A1
C
C
C
TYP
A
TYP
C1
1' - 2"
5' - 4" 8' - 8"
9' - 4"10' - 8"9' - 4"
43' - 4"
TYP
TYP
F1
TYP
TYP
TYP
TYP
TYP
9" MIN
TYP
TYP @ INTERIOR
PERIMETER/SERVICE
CORE
KEYNOTES
1 2'-0"W x 12"D CONCRETE FTG W/ (2) #5 BARS
CONTINUOUS
SEE A210 FOR TYPICAL RESTROOM FLOOR PLAN AND
INTERIOR ELEVATIONS
SEE ELECTRICAL FOR PANELS & CONTROLS
S-1 HEAVY DUTY STORAGE STEEL SHELVING, 24x48x84, ANCHOR W/ (2) WASHERED FASTENERS TO SOLID
BLOCKING NEAR TOP/UNIT
CHAINLINK FENCE TO STRUCTURE ABOVE W/ SWINGING
GATE, SEE ALSO DOOR SCHEDULE
TRENCH DRAIN, SEE ALSO PLUMBING
-BLOCK OUT SLAB AS REQ'D
FLOOR DRAIN, SEE ALSO PLUMBING AND FOUNDATION
PLAN FOR ADDITIONAL INFORMAION
METAL SECURE PASS THROUGH DOOR
DASHED LINES INDICATE ADA CLEARANCES
HOSE REEL, SEE PLUMBING
SS CORNER GUARD, +54" AFF
6" RESILIENT COVE BASE @ SERVICE CORE & REC
STORAGE, SEAL TO WALL AND FLOOR
PAINT SYSTEM FINISH @ SERVICE & STORAGE WALLS
MOP SINK, SEE PLUMBING
LOW CMU WALL, SEE ELEVATIONS
EXPOSED PLUMBING AT SERVICE SIDE, SEE PLUMBING
HATCH INDICATES ACCESS CLEARANCE SAFETY STRIPING
@ FLOOR, PS-7
PLUMBING FIXTURE, SEE ALSO TYPICAL RESTROOM
FLOOR PLAN AND PLUMBING
PROVIDE CONCRETE TURNED DOWN SLAB AT EXTERIOR
OPENEINGS, TYP
16" HT CMU STEMWALL
-(2) COURSES/8x8x16 CMU
-GROUT CELLS BELOW GRADE
HOSE BIB, SEE PLUMBING
T/FTG TO BE APPROX. 16" BELOW GRADE. BTM FTG TO
BE 26" MINIMUM TO FINISHED GRADE
SLAB CONTROL JT W/ TWO-PART SEMI-RIGID EPOXY
JOINT FILLER, COLOR TO MATCH CONCRETE.
S-2 STORAGE LOCKER,24x36x90 DOUBLE TIER GALV W/
WELDED WIRE TOP, ANCHOR W/ (2) WASHERED
FASTENERS THROUGH SS MESH TO SOLID BLOCKING
NEAR TOP/UNIT
RECEPTACLE W/ VANDAL RESISTANT LOCKABLE COVER,
SEE ELECTRICAL
APPROX LOCATION/MASONRY CONTROL JOINT, SEE
ALSO ELEVATIONS
ARROW INDIACTES DIRECTION OF SLOPE @ CONCRETE
SLAB, SLOPE TO DRAIN, MAX 1/4:12
DOWNSPOUT CONNECTION TO BELOW GRADE PIPE, SEE
ALSO PLUMBING
OPENINGS ABOVE, SEE ALSO ELEVATIONS
WATER HEATER, SEE PLUMBING
DEPRESSED SLAB AREA FOR EMBEDDED URINAL, SEE
DETAILS
FRP WALL PANEL, 2'W X 4'H, AT EA SIDE/MOP SINK,
COORDINATE WITH WALL ITEMS, CONTIN. FULL
DEPTH/RECESSED WALL AREAS @ SILL & JAMBS, SET
EDGES IN SEALANT @ TRANSITION MOLDINGS
PLUMBING PENETRATIONS SHOWN FOR REFERENCE,
COORDINATE LOCATION WITH STUD WALL
R-10 SLAB ON GRADE FOUNDATION INSULATION, SEE
DETAILS
CLEAN OUT TROUGH DRAIN, SEE PLUMBING
CLEAN OUT, SEE PLUMBING
DATE:
BID
SET
SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT #:
Rev. # Date By
BIM 360://22452 Santa Clara Community Park Restrooms/22452 Santa Clara Community Park Restrooms_Phase 05.rvt9/28/2023 4:57:36 PM
1/4" = 1'-0"
FOUNDATION &
FLOOR PLANS
915572
S A
N T
A C
L A
R A
C O
M M
U N
IT
Y
P A
R K
P
H A
S E
I
9/29/2023
A1.20
JM
BB
JM
1/4" = 1'-0"2
FLOOR PLAN
1/4" = 1'-0"1
FOUNDATION PLAN
NORTH
NORTH
0' 2' 8' 16'4'
4' - 6"
1' - 1"
9' - 1" 4' - 6"
1' - 5"
TYP
TYP
B M
-1
B M
-1
B M
-1
B M
-1
B M
-1
B M
-1
B M
-1
BM-1
BM-2BM-2BM-2
BM-3 BM-4BM-4BM-4
B M
-4
D N
1' - 0"
TYP
D N
A5.20
A5.20
A5.20
R1
TYP
KEYNOTES
1 NOT USED
2x6 T&G DECKING, SEE ALSO RCP AND ROOF ASSEMBLIES
NOT USED
NOT USED
INDICATES ROOF SLOPE
CONTINUOUS GALVANIZED 10 GAUGE GUTTER, SLOPE TO
DRAIN
DOWNSPOUT LOCATION, SEE ELEVATIONS
PROVIDE SHIM PLATE AS REQ'D FOR BEAM BEARING.
ATTACH ROOF BEAM TO TRANSFER BEAM W/ SIMPSON
H2.5A CLIP
DASHED LINE INDICATES EXTERIOR FACE/ WALL BELOW
DBL TOP PLATE AND BEVELED TOP PLATE EA SIDE/BEAM
AS REQ'S FOR ROOF SUPPORT, SEE ALSO STRUCTURAL
NOT USED
DBL TOP PLATE AND BEVELED TOP PLATE FOR BEAM
SUPPORT, SEE ALSO STRUCTURAL
PROVIDE (2) SIMPSON H2.5A CLIPS @…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .