This document is a Questions and Answers (Q&A) file for Solicitation 0012352348, dated 9/11/2025, related to a Tronair Hydraulic Power Unit (HPU). The Q&A provides technical specifications for the HPU, including power requirements of 208 to 240 V +10%/-15%, 3-phase, 50/60 Hz, with a full load input current of 107 to 93 A for UH60L & M models. Additionally, the document specifies that the unit requires MIL-PRF-83282 fluid, indicating this is a military or aerospace-related procurement for specialized equipment.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOLICITATION 0012352348 QUESTIONS AND ANSWERS
9/11/2025
1. Can you provide your facility’s 3ph facility power voltage needed for the HPU?
-Input: 208 to 240 V +10%/-15%, 3-phase, 50/60 Hz; full load input current 107 to 93 A respectively -all connections for uh60L & M models
2. Please provide me the manufacture name of this solicitation
TRONAIR
3. What fluid does this unit require?
Fluid required is MIL-PRF-83282