This document is a Bid Specification for the State of California's Department of Forestry and Fire Protection (CAL FIRE) for fixed Self-Contained Breathing Apparatus (SCBA) compressor units. The compressor units will be used to fill air containers for SCBA systems employed by CAL FIRE personnel in Immediately Dangerous to Life or Health (IDLH) environments. The units must meet various technical requirements, including NFPA standards, a minimum SCFM and horsepower, ASME storage tanks, and NFPA blast-protected refilling cabinets. The bid specification outlines three different power circuit options for the compressor units - phased power, three-phase power, and high-yield. This bid opportunity is related to a state and local contract for SCBA compressors that includes Riverside County and Palo Alto City as the participating jurisdictions. The IFB indicates that there will be a bidder's conference held as part of this solicitation.
The bid specification does not provide details on pricing, funding sources, or set asides. It also does not mention any incumbent contractors or the current environment for this type of equipment. The key requirements focus on the technical specifications and performance capabilities of the SCBA compressor units.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 0000030124_Att_1_Pricing_Worksheet.xlsx | XLSX spreadsheet | |
| 0000030124_IFB_SCBA_Compressors_Addendum_2.docx | DOCX document | |
| 0000031024_APP_Cover_Page.docx | DOCX document | |
| 0000030124_Att_3_IFB_Narrative_Response.docx | DOCX document | |
| Addendum_2_-_Cover_Sheet.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
State of California Bid Specification
FIXED SELF-CONTAINED BREATHING
APPARATUS (SCBA) COMPRESSOR
UNITS
4210-0301845_1, R0 Event ID: 0000030124
Attachment 2
Minton, W. Page 1 of 3 2/13/2024
Document Summary Detail Type Detail Event ID 0000030124 Commodity FIXED SELF-CONTAINED BREATHING APPARATUS (SCBA)
COMPRESSOR UNITS
Attachment 2 Bid Specification 4210-0301845_1 Revision Date 2/13/2024 Agency Name Department of Forestry and Fire Protection
Revision History Rev Level
Revision Date
Author Summary of Changes
0 2/13/2024 William Minton Initial Release
1.0 SCOPE
This specification describes the requirements for fixed Self-Contained Breathing Apparatus (SCBA) compressor units to be purchased for the CAL FIRE training centers and stations statewide. These fixed SCBA compressor units will be used to fill air containers for use with SCBA systems which will be employed in Immediately Dangerous to Life or Health (IDLH) environments by CAL FIRE personnel. The compressor units shall include all required components necessary for installation at the time of delivery. All equipment provided shall meet form, fit, function and performance.
The units shall be supplied with all equipment and accessories indicated as standard equipment in the manufacturer’s published literature. Optional equipment necessary to meet the minimum requirements of this specification shall be installed.
All necessary equipment and parts not specifically mentioned which form part of the completed units required for its function shall be provided and installed, and shall conform in design, strength, quality of materials, and workmanship to the highest standards of engineering practices. No prototypes shall be offered to bid.
2.0 APPLICABLE LAWS and INDUSTRY STANDARDS
Specifications, standards, and codes referenced in this document in effect on the opening of the ‘Invitation for Bid’, form a part of this specification.
2.1 National Fire Protection Association (NFPA)
FIXED SELF-CONTAINED BREATHING
APPARATUS (SCBA) COMPRESSOR
UNITS
4210-0301845_1, R0
Minton, W. Page 2 of 3 2/13/2024
2.2 American Society of Mechanical Engineers (ASME)
3.0 TECHNICAL REQUIREMENTS
3.1 General Requirements for Fixed SCBA Compressor Units
3.1.1 Compressor, cylinders and fill station shall be mounted on an enclosed single platform
3.1.2 National Fire Protection Association (NFPA) 1901-2016 standard sealed unit
3.1.3 National Fire Protection Association (NFPA) 1989 Grade E air purification system
3.1.4 6000 Pounds per Square Inch, Gauge (PSIG)
3.1.5 Carbon Monoxide (CO) monitor included
3.1.6 Moisture monitor included
3.1.7 A minimum of one quick connect fill hose of each type listed below for each fill valve in the refilling cabinet. (Adapters are acceptable if required)
3.1.7.1 3,000 pound cylinders
3.1.7.2 4,500 pound cylinders
3.1.7.3 Self-Contained Underwater Breathing Apparatus (SCUBA) tanks
3.1.8 Optional Compressor Specifications
3.1.8.1 100 foot quick connect hose reel unregulated with CGA 677 connection rated for 6000 PSIG
3.1.8.1.1 separately wall mounted or integrated (Only a single continuous run of hose shall be accepted)
3.2 Fixed SCBA Compressor Units- Phased Power Circuits
3.2.1 A minimum of 13 Standard Cubic Feet per Minute (SCFM)
3.2.2 A minimum of 10 horsepower (HP) Available with single phase and three phase, dependent upon the location requirements
3.2.2.1 Single phase 230 Volt
3.2.2.2 Three phase voltages (208 Volt, 230 Volt, and 460 Volt)
3.2.3 Two (2) American Society of Mechanical Engineers (ASME) storage tanks with one certified pressure relief Kunkle valve per cylinder
3.2.4 An NFPA blast-protected refilling cabinet with the capacity to refill a minimum of two
(2) cylinders at once.
3.2.4.1 Adjustable height to allow for different sizes of cylinders ranging from 20 inches to 31 inches
FIXED SELF-CONTAINED BREATHING
APPARATUS (SCBA) COMPRESSOR
UNITS
4210-0301845_1, R0
Minton, W. Page 3 of 3 2/13/2024
3.3 Fixed SCBA Compressor Units-Three Phase Power Circuits
3.3.1 A minimum of 18 Standard Cubic Feet per Minute (SCFM)
3.3.2 A minimum of 15 horsepower (HP) for three phase voltages (208 Volt, 230 Volt, and 460 Volt)
3.3.3 Four (4) American Society of Mechanical Engineers (ASME) storage tanks with one certified pressure relief Kunkle valve per cylinder
3.3.4 An NFPA blast-protected refilling cabinet with the capacity to refill a minimum of two
(2) cylinders at once.
3.3.4.1 Adjustable height to allow for different sizes of cylinders ranging from 20
3.4 Fixed SCBA Compressor Units-High Yield
3.4.1 A minimum of 33 Standard Cubic Feet per Minute (SCFM)
3.4.2 A minimum of 25 horsepower (HP) for three phase voltages (208 Volt, 230 Volt, and 460 Volt)
3.4.3 Four (4) American Society of Mechanical Engineers (ASME) storage tanks with one certified pressure relief Kunkle valve per cylinder
3.4.4 An NFPA blast-protected refilling cabinet with the capacity to refill a minimum of three
(3) cylinders at once.
3.4.4.1 Adjustable height to allow for different sizes of cylinders ranging from 20
| Document Summary |
| 1.0 SCOPE |
| 2.0 APPLICABLE LAWS and INDUSTRY STANDARDS |
| Specifications, standards, and codes referenced in this document in effect on the opening of the ‘Invitation for Bid’, form a part of this specification. |
| 3.0 TECHNICAL REQUIREMENTS |
| 3.1.1 Compressor, cylinders and fill station shall be mounted on an enclosed single platform |
| 3.1.2 National Fire Protection Association (NFPA) 1901-2016 standard sealed unit |
| 3.1.3 National Fire Protection Association (NFPA) 1989 Grade E air purification system |
| 3.1.4 6000 Pounds per Square Inch, Gauge (PSIG) |
| 3.1.5 Carbon Monoxide (CO) monitor included |
| 3.1.6 Moisture monitor included |
| 3.1.7 A minimum of one quick connect fill hose of each type listed below for each fill valve in the refilling cabinet. (Adapters are acceptable if required) |
| 3.1.8 Optional Compressor Specifications |
| 3.1.8.1 100 foot quick connect hose reel unregulated with CGA 677 connection rated for 6000 PSIG |
| 3.1.8.1.1 separately wall mounted or integrated (Only a single continuous run of hose shall be accepted) |
| 3.2.1 A minimum of 13 Standard Cubic Feet per Minute (SCFM) |
| 3.2.2 A minimum of 10 horsepower (HP) Available with single phase and three phase, dependent upon the location requirements |
| 3.2.3 Two (2) American Society of Mechanical Engineers (ASME) storage tanks with one certified pressure relief Kunkle valve per cylinder |
| 3.2.4 An NFPA blast-protected refilling cabinet with the capacity to refill a minimum of two (2) cylinders at once. |
| 3.2.4.1 Adjustable height to allow for different sizes of cylinders ranging from 20 inches to 31 inches |
| 3.3.1 A minimum of 18 Standard Cubic Feet per Minute (SCFM) |
| 3.3.2 A minimum of 15 horsepower (HP) for three phase voltages (208 Volt, 230 Volt, and 460 Volt) |
| 3.3.3 Four (4) American Society of Mechanical Engineers (ASME) storage tanks with one certified pressure relief Kunkle valve per cylinder |
| 3.3.4 An NFPA blast-protected refilling cabinet with the capacity to refill a minimum of two (2) cylinders at once. |
| 3.3.4.1 Adjustable height to allow for different sizes of cylinders ranging from 20 inches to 31 inches |
| 3.4.1 A minimum of 33 Standard Cubic Feet per Minute (SCFM) |
| 3.4.2 A minimum of 25 horsepower (HP) for three phase voltages (208 Volt, 230 Volt, and 460 Volt) |
| 3.4.3 Four (4) American Society of Mechanical Engineers (ASME) storage tanks with one certified pressure relief Kunkle valve per cylinder |
| 3.4.4 An NFPA blast-protected refilling cabinet with the capacity to refill a minimum of three (3) cylinders at once. |
| 3.4.4.1 Adjustable height to allow for different sizes of cylinders ranging from 20 inches to 31 inches |
File details come from the government source that posted it. Updated .