Integration of sotair with capnography for standardizing manual ventilation technique and improving patient outcomes
Active Project Grant Awarded Last action
- Award ID
- SB1HL182470
- Recipient
-
Safebvm Corp. UEI U5AEE4JR6QD9
- Awarding agency
-
National Heart Lung and Blood Institute
National Institutes of Health, Department of Health and Human Services
- Obligated
- $499,932
Award facts
- Assistance listing
- 93.837 Cardiovascular Diseases Research
- Completion date 57% complete
- Originally
- Place of performance
- Boston, MA 02109, USA
Award details come from USAspending.gov.
About this award
The National Heart, Lung, and Blood Institute awarded $499,932 to Safebvm Corp. on September 17, 2025, under the Cardiovascular Diseases Research program (CFDA 93.837) to integrate capnography sensing into the SOTAIR device for standardizing manual ventilation technique and improving patient outcomes.
SOTAIR is a lightweight (14 grams), battery-free attachment device compatible with all commercially available bag-valve masks that employs flow-blocking and pressure-control mechanisms to automatically restrict unsafe flow rates exceeding 55 liters per minute while providing real-time audiovisual feedback to guide provider technique. The integrated capnography enhancement will enable real-time end-tidal CO2 monitoring and ventilation control, reducing workflow complexity and dead space while addressing the prevalence of incorrect manual ventilation delivery in emergency settings and associated complications including gastric insufflation, aspiration pneumonia, and acute lung injury or acute respiratory distress syndrome.
Safebvm Corp., a minority-owned small disadvantaged business based in Boston, Massachusetts, is the recipient. Performance occurs in Boston, MA, with a period of performance extending through August 31, 2027. This is a Small Business Innovation Research (SBIR) Project Grant.
Description
- Abstract
- Safebvm is transforming emergency ventilation through our innovative sotair device, addressing the widespread risks of improper manual ventilation. Manual ventilation remains a gold standard of emergency and critical care, yet IT is often delivered incorrectly, up to 81% of the time in emergency settings. Unsafe manual ventilation leads to severe complications such as gastric insufflation, aspiration pneumonia, risk of acute lung injury (ALI) and acute respiratory distress syndrome (ARDS), which have hefty treatment costs ranging from $36,000 to $140,000 per patient. These preventable outcomes highlight the critical need for a device that ensures safe and guideline- compliant manual ventilation. The sotair addresses these challenges through a flow-blocking and pressure- control mechanism which automatically restricts unsafe flow rates exceeding 55 L/min. IT also provides real-time audiovisual feedback, guiding providers to adjust their technique for safe and effective ventilation. At just 14 grams, sotair is lightweight, compatible with all commercially available bag-valve masks and airway devices, and requires no external power source. Its integration into emergency workflows will facilitate personalized ventilation while significantly reducing complications. Based on both studies in the literature and discussions with EMS personnel and key opinion leaders (KOLS), further improvements in ventilation could be gained by integrating a capnography sensor into the sotair, enabling real-time end-tidal CO₂ (etco₂) monitoring as well as ventilation control while also reducing workflow complexity and minimizing dead space. By combining ventilation control with real-time etco₂ monitoring, this novel device will not only simplify emergency airway management but also result in further improvements in patient outcomes, reducing life-threatening complications associated with improper manual ventilation. The specific aims of this project are as follows: aim 1) design, engineering, and prototyping of the sotair + capnography integrated device. Aim 2) testing and preparation of filing for regulatory approval. These efforts will result in the preparation of a comprehensive submission for FDA clearance and will pave the way for successful commercialization of the sotair device. This innovation positions sotair as the new gold standard for manual ventilation, enabling safer and more effective care even in resource- limited emergency environments.
Transactions
| Action | Obligated | Date |
|---|---|---|
| Amendment | $0 | |
| Original award | $499,932 |
Quick answers
Who received award SB1HL182470?
SB1HL182470 was awarded to Safebvm Corp. by National Heart Lung and Blood Institute (National Institutes of Health) on September 17, 2025.
How much is award SB1HL182470 worth?
$499,932 has been obligated on SB1HL182470.
On GovTribe
See this award's full record
- Every transaction and subaward
- The recipient's other awards and teaming partners
- Similar grant awards
- Ask GovTribe AI about this award