Native hemodynamic measurement as feedback control for mechanical cardiac support
Ended Grant Awarded Last action
- Award ID
- R44HL145847
- Recipient
-
Bridgesource Medical, Corp. UEI TJWEFWAH8JK6
- Awarding agency
-
National Heart Lung and Blood Institute
National Institutes of Health, Department of Health and Human Services
- Obligated
- $1,688,217
Award facts
- Assistance listing
- 93.837 Cardiovascular Diseases Research
- Completion date
- Originally
- Place of performance
- Texas, USA
Award details come from USAspending.gov.
Description
- Abstract
- Temporary mechanical circulatory support (MCS) devices have been an effective means of temporary support in patients for two indications: acute myocardial infarction (MI) with or without cardiogenic shock (CS), and acute decompensated heart failure (HF). These ailments strike the elderly the hardest and are simultaneously more prevalent as age progresses. Cardiogenic shock after MI is more common in elderly patients than in the young, and HF has increasing prevalence with age (60-79, 6% have HF, for over 80, 10% have HF). In these patients, a short- term MCS device is a catheter delivered pump that can be placed in the LV, and pump blood across the aortic valve, to help maintain forward flow while unloading the failing heart. The key metric for optimizing the use of these devices includes a combination of pressure, and volume measurement. While pressure is already commonly measured on-device, MCS devices on the market today cannot estimate the total cardiac output of the heart, a key component of cardiac power output (CPO, CO X mean aortic pressure) which is now well accepted as the single most important correlate of mortality in cardiogenic shock. Optimization of ongoing treatment as well as when to wean the patient from the MCS device to transition them to recovery (or a more permanent device) currently lacks a real-time, accurate measure of CO (necessary to calculate CPO). We propose integrating a proven LV volume measurement (admittance-based technology) capable of determining CO directly onto the MCS device, allowing the device to actively change pump speed (and therefore effect CPO) to respond to changing patient condition. In this phase 2 effort, bridgesource medical will demonstrate how admittance-based technology can be redeveloped for application on existing MCS device platforms.
Transactions
| Action | Obligated | Date |
|---|---|---|
| Amendment | $0 | |
| Amendment | $0 | |
| Amendment | $1,189,622 | |
| Original award | $498,595 |
Quick answers
Who received award R44HL145847?
R44HL145847 was awarded to Bridgesource Medical, Corp. by National Heart Lung and Blood Institute (National Institutes of Health) on June 14, 2022.
How much is award R44HL145847 worth?
$1,688,217 has been obligated on R44HL145847.
On GovTribe
See this award's full record
- Every transaction and subaward
- The recipient's other awards and teaming partners
- Similar grant awards
- Ask GovTribe AI about this award