Real-time continuous troponin monitoring: a breakthrough in personalized cardiovascular risk assessment and management - cardiovascular diseases (CVDS) remain the leading cause of death globally, with…
Ended Project Grant Awarded Last action
- Award ID
- R43HL182540
- Recipient
-
Actiox LLC UEI DWURXY4NS9R6
- Awarding agency
-
National Heart Lung and Blood Institute
National Institutes of Health, Department of Health and Human Services
- Obligated
- $699,468
Award facts
- Assistance listing
- 93.837 Cardiovascular Diseases Research
- Completion date
- Originally
- Place of performance
- La Jolla, CA 92093, USA
Award details come from USAspending.gov.
About this award
The National Heart, Lung, and Blood Institute awarded Actiox LLC $699,468 on September 10, 2025, under the Cardiovascular Diseases Research program (CFDA 93.837) for development of a wearable microneedle-based biosensor for continuous cardiac troponin I monitoring. The assistance type is a Project Grant.
Actiox will develop and optimize an electrochemical aptamer-based sensor integrated with microneedle arrays capable of real-time, ultra-sensitive monitoring of cardiac troponin I in interstitial fluid. The project comprises three specific aims: Aim 1 focuses on sensor development and optimization, including aptamer selection and functionalization, microneedle array integration, and antifouling coating optimization for signal stability in interstitial fluid. Aim 2 validates analytical performance—sensitivity, specificity, and multi-day stability—in contrived interstitial fluid and human serum under physiologically relevant conditions. Aim 3 evaluates clinical feasibility (description truncated in source). The wearable device is intended to enable earlier detection of ischemic events and personalized therapeutic interventions by providing clinicians continuous insights into troponin kinetics, addressing gaps in current high-sensitivity cardiac troponin assays that rely on intermittent blood sampling and frequently fail to detect transient or silent ischemic events.
Performance location is La Jolla, California. The period of performance runs through October 31, 2026.
Description
Real-time continuous troponin monitoring: a breakthrough in personalized cardiovascular risk assessment and management - cardiovascular diseases (CVDS) remain the leading cause of death globally, with acute coronary syndromes (ACS) and myocardial infarctions (MIS) representing major clinical and economic challenges. Current diagnostic methods, such as high-sensitivity cardiac troponin (HS-CTN) assays, rely on intermittent blood sampling and often fail to detect transient or silent ischemic events, leading to delayed diagnosis and suboptimal treatment. This diagnostic GAP highlights the need for continuous, real-time biomarker monitoring to improve outcomes for patients at risk of ACS. Addressing this need, we propose the development of a wearable microneedle-based biosensor for continuous cardiac troponin I (CTNI) monitoring. The overall goal of this project is to demonstrate the feasibility of a transformative biosensor capable of real-time, reversible, and ultra-sensitive monitoring of CTNI in interstitial fluid (ISF). The proposed sensor integrates microneedle technology with aptamer-based electrochemical biosensing to achieve high sensitivity, specificity, and long-term stability in complex biofluid environments. This wearable device will provide clinicians with actionable insights into troponin kinetics, enabling earlier detection of ischemic events and personalized therapeutic interventions. The project is structured around three specific aims: in aim 1, the electrochemical aptamer-based sensor for CTNI detection will be developed and optimized. This includes the selection and functionalization of aptamers, integration with microneedle arrays, and optimization of antifouling coatings to ensure robust signal stability in ISF. Aim 2 validates the sensor's analytical performance in contrived ISF and human serum. This will include assessing sensitivity, specificity, and stability over multi-day operation in physiologically relevant conditions. Finally, aim 3 evaluates the biocompatibility and sterility of the microneedle sensor to ensure safe, extended skin contact. The sensor will be tested for cytotoxicity and sterility using ISO-compliant protocols to prepare IT for future human applications. This project also addresses the longstanding challenge of integrating biomarker diagnostics with wearable technologies, bridging the GAP between laboratory-grade accuracy and real-world usability. The proposed research will establish the feasibility of a novel wearable CTNI monitoring platform, addressing critical gaps in cardiac diagnostics and advancing precision medicine. The device's modular design allows integration with complementary biomarkers such as NT-probnp, enabling comprehensive cardiac health profiling. Furthermore, its affordability and scalability will support widespread adoption, transforming cardiac care in both resource-limited and high-resource settings. Beyond individual benefits, this technology has the potential to reduce unnecessary hospitalizations, optimize resource utilization, and democratize access to advanced diagnostics in underserved settings. By focusing on continuous cardiac biomarker monitoring, this project aligns with the national heart, lung, and blood institute's (NHLBI) mission to promote innovative technologies that improve health outcomes and reduce the burden of cardiovascular diseases.
Transactions
| Action | Obligated | Date |
|---|---|---|
| Amendment | $0 | |
| Amendment | $349,734 | |
| Original award | $349,734 |
Quick answers
Who received award R43HL182540?
R43HL182540 was awarded to Actiox LLC by National Heart Lung and Blood Institute (National Institutes of Health) on September 10, 2025.
How much is award R43HL182540 worth?
$699,468 has been obligated on R43HL182540.
On GovTribe
See this award's full record
- Every transaction and subaward
- The recipient's other awards and teaming partners
- Similar grant awards
- Ask GovTribe AI about this award