A wearable magnetocardiography imaging system

Ended Project Grant Awarded Last action

Award ID
R43HL165987
Recipient
Awarding agency
Obligated
$1,991,560

Award facts

Assistance listing
93.837 Cardiovascular Diseases Research
Completion date
Originally
Funding
  • $1,493,670.00 Federal
  • $497,890.00 Non-federal
Place of performance
Colorado, USA

Award details come from USAspending.gov.

Description

Abstract
Recent studies have shown radiation therapy (RT) ablation to be a highly promising alternative therapy for patients with drug-refractory VT who are unable to undergo catheter-based ablation. Ideally, RT ablation is performed in conjunction with noninvasive electrophysiology (EP) imaging, such as ECG imaging (ecgi), so that the entire procedure is noninvasive; however, currently noninvasive EP imaging is much less accurate than RT and needs to be significantly improved to realize the full potential of RT ablation. In this project, we propose to utilize magnetocardiography (MCG) to develop an MCG imaging (mcgi) system. In comparison to ECG, MCG provides fundamental advantages for source localization and imaging due to the favorable transmission properties of magnetic signals. From a practical standpoint, MCG is more convenient because IT is a contactless technique, whereas ecgi requires application of a large array of electrodes. The proposed system will be based on a revolutionary type of magnetic sensor, known as an optically-pumped magnetometer (OPM), which was first brought to market by our company. Opms are far more practical than squid magnetometers because they are smaller, less expensive, and operate at room temperature. This will enable construction of an mcgi system with a conformal sensor array that covers the entire torso. The overall goal is to construct an mcgi system with improved accuracy and ease-of-use, compared to current ecgi/mcgi systems. The phase i aims are to 1) determine an optimal sensor configuration for the mcgi system based on analysis of the spatial properties of the signal, 2) design a compact magnetic shield that is patient-friendly and minimizes the space requirements of the system, 3) devise a strategy for rapid, accurate digitization of the sensor locations, and 4) demonstrate the feasibility of key aspects of the proposed techniques in a small study of normal subjects.

Transactions

Action Federal Non-federal Date
Amendment $0 $0
Amendment $0 $0
Amendment $497,890 $0
Amendment $497,890 $497,890
Original award $497,890 $0

Quick answers

Who received award R43HL165987?

R43HL165987 was awarded to Quspin Inc. by National Heart Lung and Blood Institute (National Institutes of Health) on September 1, 2022.

How much is award R43HL165987 worth?

$1,991,560 has been obligated on R43HL165987: $1,493,670 in federal funding and $497,890 in non-federal funding.

On GovTribe

See this award's full record

  • Every transaction and subaward
  • The recipient's other awards and teaming partners
  • Similar grant awards