Development of an instant freezing sample preparation system for cryo-EM
Ended Project Grant Awarded Last action
- Award ID
- R43GM145044
- Recipient
-
Hummingbird Precision Machine CO. UEI YL5LGSA9X7N3
- Awarding agency
-
National Institute of General Medical Sciences
National Institutes of Health, Department of Health and Human Services
- Obligated
- $474,610
Award facts
- Assistance listing
- 93.859 Biomedical Research and Research Training
- Completion date
- Originally
- Place of performance
- Washington, USA
Award details come from USAspending.gov.
Description
- Abstract
- Project title: development of an instant freezing sample preparation system for CRYO-EM company name: hummingbird precision machine CO., DBA hummingbird scientific principal investigator: norman salmon summary: the field of cryogenic electron microscopy (CRYO-EM) has rapidly been gaining traction as a structural characterization technique for proteins. Sample preparation for CRYO-EM is advantageous over other proven techniques like X-RAY crystallography as proteins do not need to be crystallized for high-resolution structural analysis. While the CRYO-EM sample preparation technique keeps proteins in their native form, CRYO-EM suffers from a bottleneck in both quality and throughput of samples. Recent advances in the field have focused on increasing sample throughput through automated preparation techniques. However, the more important problem in CRYO-EM samples now has become protein damage from the air-water interface. Before vitreous freezing, proteins in the sample droplet collide and stick to the droplet surface, where they denature to form an unraveled monolayer. The more time the sample is exposed before freezing, the more time proteins have time to interact with the surface and denature. Current commercial systems fail to directly address the problems associated with the interface, focusing instead on the automated production of samples with thin, vitreous ICE. While these improvements are valuable to the overall goals of reducing ICE thickness, they ignore damage to the sample molecules themselves, preventing users from repeatably obtaining high-resolution structures. The proposed project aims to revolutionize sample preparation techniques for CRYO-EM by exploring a method of generating higher quality samples that exhibit significantly less damage from the air-water interface. The proposed system aims to limit sample exposure to the air-water interface by reducing the rate of freezing by an order of magnitude. In order to reduce damage from the air-water interface with high quality samples, the system will aim to vitrify samples in less than 10 MS with a large percentage of ICE suitable for high-resolution imaging. This "fast freezing" system also is also conceived to populate sample grids with consistently thin ICE by reducing the amount of excess water that is frozen on the grid, creating larger areas of uniform ICE and biomolecular sample per grid. Hummingbird scientific aims to develop and test the theory behind the system in phase I.
Transactions
| Action | Obligated | Date |
|---|---|---|
| Amendment | $0 | |
| Amendment | $0 | |
| Amendment | $237,305 | |
| Original award | $237,305 |
Quick answers
Who received award R43GM145044?
R43GM145044 was awarded to Hummingbird Precision Machine CO. by National Institute of General Medical Sciences (National Institutes of Health) on August 1, 2022.
How much is award R43GM145044 worth?
$474,610 has been obligated on R43GM145044.
On GovTribe
See this award's full record
- Every transaction and subaward
- The recipient's other awards and teaming partners
- Similar grant awards
- Ask GovTribe AI about this award