Determining reliability and efficacy of intraoperative sensors to reduce structural damage during cochlear implantation

Ended Project Grant Awarded Last action

Award ID
R43DC021397
Recipient
Awarding agency
Obligated
$274,937

Award facts

Completion date
Place of performance
Pennsylvania, USA

Award details come from USAspending.gov.

Description

Abstract
HL is a leading cause of disability worldwide, responsible for an estimated $981B in global costs. When acoustic amplification of hearing aids is no longer an effective treatment, patients can receive a cochlear implant (CI). Currently, the surgeon threads the electrode array into the spiral cochlea, risking structural damage that destroys residual acoustic hearing and impacts overall hearing outcomes. Consequently, adoption rates remain extremely low: 5% of the eligible population in the US. Advanced optronics (AO) is developing a novel surgeon guidance system using a microelectromechanical system (mems) sensor array that will be seamlessly integrated with existing CI electrode array designs to detect bending and forces acting on the array to warn surgeons of potential risks. Using advanced polymer microfabrication techniques, AO has produced ultra-thin and flexible sensors that can be incorporated into CI electrodes with minimal impact on the CI electrode size or mechanics. This phase i proposal will demonstrate the feasibility of the system from a fabrication, usability, and regulatory perspective. The phase i results will pave the way for clinical translation during phase II. The specific aims for the phase i project are: specific aim 1: determining sensor reliability with a cochlear implant electrode: the complete system (CI + sensor) will be iteratively improved for robustness and reliability to maximize two key metrics: 1. Measurement reliability, and 2. Attachment robustness. Specific aim 2: demonstrating sensor effectiveness to improve surgeon technique: the system's efficacy will be validated via surgeon insertion in 3D printed cochlear models. Surgeons will systematically vary insertion technique and data collected in these trials will be evaluated to show that real-time feedback allows surgeons to minimize insertion forces. Specific aim 3: determining regulatory pathway and requirements: a detailed regulatory proposal will be prepared to cover intended use, regulatory descriptions of hardware and software components, and studies to support safety and effectiveness. A pre-submission briefing document will be prepared for an early and comprehensive FDA discussion on product development and registration strategies.

Transactions

Action Obligated Date
Amendment $0
Original award $274,937

Quick answers

Who received award R43DC021397?

R43DC021397 was awarded to Advanced Optronics Inc. by National Institute on Deafness and Other Communincation Disorders (National Institutes of Health) on August 10, 2023.

How much is award R43DC021397 worth?

$274,937 has been obligated on R43DC021397.

On GovTribe

See this award's full record

  • Every transaction and subaward
  • The recipient's other awards and teaming partners
  • Similar grant awards
  • Ask GovTribe AI about this award