Project Grant R41DE029727

Award Date 9/21/21
Completion Date 9/21/23
Dollars Obligated $665K
Federal Grant Program
93.121
Assistance Type
Project Grant
Place of Performance
St. Louis, MO 63108, USA
Similar Awards
This $536,954 Project Grant awarded by the National Institute of Biomedical Imaging and Bioengineering (NIBIB) under the Discovery and Applied Research for Technological Innovations to Improve Human Health program (CFDA 93.286) will fund research and development of a novel ultra-high-spatial resolution computed tomography (UHR-CT) system using photon-counting detectors and multiple x-ray focal spots. The research aims to overcome limitations of current high-resolution CT systems by developing...
The National Institute of Dental and Craniofacial Research (NIDCR) awarded a $150,989 Project Grant under the Oral Diseases and Disorders Research (CFDA 93.121) program to The Research Foundation for The State University of New York, doing business as Stony Brook University. The goal of this 2-year project is to develop an automated tool to detect and characterize arterial calcifications in dental cone beam computed tomography (CBCT) scans. This research aims to establish quantifiable imaging...
The National Institute of Biomedical Imaging and Bioengineering (NIBIB) awarded a $719,124 Cooperative Agreement under the Discovery and Applied Research for Technological Innovations to Improve Human Health program (CFDA 93.286) to The Johns Hopkins University on July 15, 2025. The project aims to develop the next generation of photon counting detectors (PCDs) with multi-energy inter-pixel coincidence counter (MEICC) and digital pulse energy correction (DPEC) functionality for X-ray computed...
This Project Grant award from the National Institute of Biomedical Imaging and Bioengineering (NIBIB), under the Discovery and Applied Research for Technological Innovations to Improve Human Health program (CFDA 93.286), provides $616,033 to the University of California, Davis to develop and validate a PET-enabled dual-energy CT (DECT) imaging method. The goal is to create a technique that can derive a high-energy gamma-ray CT (GCT) image from standard PET/CT emission data, and combine it with...
This federal Project Grant award of $306,633, provided by the National Institute of Dental and Craniofacial Research (NIDCR) under the Oral Diseases and Disorders Research (CFDA 93.121) program, is funding the development of CRANIAMAP, a software suite for automated segmentation and landmarking of cone-beam computed tomography (CBCT) scans. The award recipient, Ther-Ai LLC, aims to create a robust, comprehensive solution to enhance the speed and accuracy of critical diagnostic processes in...
This Project Grant award from the National Institute of Dental and Craniofacial Research (NIDCR), under the Oral Diseases and Disorders Research program (CFDA 93.121), aims to develop a multifunctional, 3D-printed dental implant capable of preventing peri-implantitis, a common and challenging implant-related oral infection. The $1,963,287 award to Cleveland State University will fund the development of silver-doped amorphous magnesium phosphate bioceramic particles, which will be incorporated...
This federal Project Grant award from the National Institute of Dental and Craniofacial Research (NIDCR), under the Oral Diseases and Disorders Research program (CFDA 93.121), provides $294,632 to Greenmark Biomedical Inc. to develop an intraoral camera system that can detect and monitor early-stage dental caries (tooth decay) using nanoparticle-enhanced imaging and artificial intelligence (AI) software. The key products to be delivered under this award include a minimally viable prototype of...
This $1.2 million project grant from the National Science Foundation's Division of Computing and Communication Foundations, under the Computer and Information Science and Engineering program (CFDA 47.070), supports the development of novel model-based iterative reconstruction algorithms for high-resolution computed tomography imaging from low-dose X-ray data. The University of Florida will leverage techniques from approximation theory and performance optimization tools to address computational...
This Project Grant award from the National Institute of Dental and Craniofacial Research (NIDCR), under the Oral Diseases and Disorders Research federal grant program (CFDA 93.121), provides $533,675 to the Trustees of Dartmouth College to conduct research on improving bone quality and regeneration in head and neck cancer patients after radiation therapy. The key objectives are to: Develop a combined 3D-printed mineral framework and cryogel scaffold to enhance bone formation and resist...
This Project Grant award of $606,296 from the National Institute of Dental and Craniofacial Research (NIDCR), under the Oral Diseases and Disorders Research program (CFDA 93.121), will develop advanced 3D growth models of the craniofacial complex using state-of-the-art cone-beam computed tomography (CBCT) imaging. The models will incorporate a large, racially/ethnically diverse database of 40,000 CBCT images to analyze craniofacial growth patterns across age, sex, race, ethnicity, facial type,...

SUPER-RESOLUTION DUAL-ENERGY DENTAL CT BASED ON DISTRIBUTED X-RAY SOURCE AND PHOTON COUNTING DETECTOR - ABSTRACT WITH CONE-BEAM CT'S INTRODUCTION IN DENTISTRY, DENTAL CLINICIANS COULD NOT ONLY HAVE PROFOUND KNOWLEDGE OF ORAL PATHOLOGY BUT COULD ALSO ENHANCE THE ACCESS TO A DETAILED VIEW OF THE UNDERLYING STRUCTURES AND THEIR RELATIONS. DENTAL CBCT COULD BE JUSTIFIED FOR PRESURGICAL DIAGNOSIS, PREOPERATIVE PLANNING AND PREOPERATIVE TRANSFER FOR ORAL IMPLANT REHABILITATION. THE IMAGE QUALITY OF CBCT, HOWEVER, IS SUBOPTIMAL AND SUFFERS FROM STRONG IMAGE ARTIFACTS STEMMING FROM EXCESSIVE X-RAY SCATTERING, LIMITED DETECTOR PERFORMANCE. SPATIAL RESOLUTION, THE MOST IMPORTANT PARAMETER OBJECTIVELY DEFINING IMAGE QUALITY, IS INSUFFICIENT FOR MANY DENTAL APPLICATIONS WHERE THE FINE DETAILS OFTEN HAVE TO BE DEPICTED. WE WILL DEVELOP AND VALIDATE A NOVEL DENTAL IMAGING SYSTEM THAT NOT ONLY FUNDAMENTALLY ELIMINATES THE IMAGE QUALITY PROBLEMS AND BUT ALSO CAN PRODUCE SUPERIOR IMAGE RESOLUTION IN 3D IMAGES. THE SUPER-RESOLUTION DUAL-ENERGY TETRAHEDRON BEAM CT (TBCT) EMPLOYS A NOVEL MULTI-PIXEL THERMIONIC EMISSION X-RAY (MPTEX) SOURCE WITH WOBBLING FOCAL SPOTS AS WELL AS AN ENERGY-RESOLVED PHOTON-COUNTING DETECTOR (PCD). TBCT SCANS THE PATIENT WITH A STACK OF FAN BEAMS THAT HAVE A VERY LOW SCATTER-TO-PRIMARY RATIO (SPR); THE PCD DETECTOR CAN COUNT X-RAY PHOTONS WITHOUT ELECTRONICS NOISES, THUS CAN REDUCE RADIATION EXPOSURE AND DENTAL ARTIFACTS DUE TO PHOTON STARVATION; THE DUAL-ENERGY CAPACITY OF PCD FURTHER ELIMINATES BEAM-HARDENING ARTIFACTS AND SUPPORTS MATERIAL DECOMPOSITION; THE FLYING FOCAL SPOTS AND TIME-DELAY-INTEGRATION (TDI) DETECTION WILL COMPENSATE GANTRY MOTION, AND SUPER-RESOLUTION 3D IMAGES CAN BE RECONSTRUCTED WITH OPTICS-MODEL BASED ITERATIVE IMAGE RECONSTRUCTION (IIR). SUPER-RESOLUTION DENTAL TBCT WILL FIT IN THE GAP OF HIGH-PERFORMANCE 3D IMAGING IN DENTISTRY, ALLOW FURTHER ADVANCING THE PRODUCTIVITY AND QUALITY OF CARE IN DENTAL PRACTICE. THE FOLLOWING SPECIFIC AIMS HAVE BEEN DESIGNED TO ACCOMPLISH THIS GOAL: AIM 1: DEVELOP MPTEX SOURCE WITH VARIABLE FOCAL SPOT SIZE AND LOCATION; AIM 2: TO DEVELOP AND VALIDATE A SUPER-RESOLUTION DENTAL TBCT BENCHTOP IMAGING SYSTEM.

Posted 9/21/21