Medical device identifier to improve emergency triage

Active Grant Awarded

Award ID
SB1AG102150
Recipient
Awarding agency
Obligated
$1,511,003

Award facts

Assistance listing
93.866 Aging Research
Completion date 11% complete
Place of performance
Austin, TX 78731, USA

Award details come from USAspending.gov.

About this award

The Department of Health and Human Services National Institutes of Health National Institute on Aging awarded Bridgesource Medical, Corp. $1.511 million on September 17, 2026, under the Aging Research program (CFDA 93.866) through Grant SB1AG102150. The award funds a portable handheld device that identifies cardiovascular implantable electronic devices (CIEDs), such as permanent pacemakers and implantable defibrillators, from any manufacturer, either in the emergency department or in transit to it. The device mimics the "wakeup call" communication of the five major CIED programmers in sequence and identifies each device by analyzing the CIED's response. The proposed device is intended to eliminate the time-consuming X-ray reads and database searches that can take from 30 minutes to hours during emergency triage, and to enable first-line medical personnel to identify devices.

Performance runs from the September 17, 2026 award date through an ultimate completion date of May 31, 2028, with place of performance in Austin, TX 78731, USA. The recipient's UEI is TJWEFWAH8JK6.

Description

Abstract
Cardiovascular implantable electronic devices (CIEDS) like a permanent pacemaker or implantable defibrillator are implanted in over 3 million americans, with the average age of implantation in the 60S, 40% ≥ 70 years old, and 28% ≥ 80 years old. When a patient presents to the emergency department (ED) with an unknown cied, reprogramming of the device is often necessary for their treatment. Every patient should know their device type and manufacturer. This information is particularly important, as every device can be interrogated only by a programmer (a custom computer and magnetic wand) from the cied's specific manufacturer. However, in emergency situations, older patients may not have their device information or may be unable to communicate with hospital personnel, leading to delays in proper treatment. The current standard of care to identify the device can stretch from 30 minutes through to hours overnight, exacerbating emergency department crowding and creating unnecessary distress for patients. Standard of care techniques include attempting to read X-rays, time consuming database searches, and attempting to call family members or implanting clinicians. To facilitate prompt and thorough patient treatment, cied manufacturers typically provide personnel who are on call in or near medical facilities to assist with any device-related issues. To solve this problem, bridgesource medical proposes a portable handheld device that can identify CIEDS from any manufacturer either in the ED, or in transit to the ED, eliminating the need for a time-consuming and unnecessary X-RAY, and enabling first-line medical personnel. The proposed device identifier works by mimicking the "wakeup call" communication of the five major cied programmers in sequence and would identify each device by analyzing the response from the cied.

Quick answers

Who received award SB1AG102150?

SB1AG102150 was awarded to Bridgesource Medical, Corp. by National Institute on Aging (National Institutes of Health) on September 17, 2026.

How much is award SB1AG102150 worth?

$1,511,003 has been obligated on SB1AG102150.