Low-loss bidirectional THZ couplers to enable affordable MAS-DNP-NMR abstract transformational advances for solid-state NMR (SSNMR) are crucial for both structural biology research, biomedical…
Active Grant Awarded
- Award ID
- R44GM156167
- Recipient
-
Doty Scientific Inc. UEI ZEWHLT5Y7H33
- Awarding agency
-
National Institute of General Medical Sciences
National Institutes of Health, Department of Health and Human Services
- Obligated
- $994,403
Award facts
- Assistance listing
- 93.859 Biomedical Research and Research Training
- Completion date 7% complete
- Place of performance
- Columbia, SC 29229, USA
Award details come from USAspending.gov.
About this award
The National Institute of General Medical Sciences, within the National Institutes of Health and the Department of Health and Human Services, awarded Doty Scientific Inc. of Columbia, South Carolina, $994,403 under Grant R44GM156167 on September 7, 2026, through the Biomedical Research and Research Training program (CFDA 93.859). The grant funds development of low-loss bidirectional terahertz couplers for affordable magic angle spinning dynamic nuclear polarization (MAS-DNP) NMR. The source states that current high-field MAS-DNP systems require gyrotrons, which add $2-9M to system cost and have narrow bandwidth. The project pursues cavity-based designs that use microwave power more efficiently, combined with ultra-low-temperature operation, to enable MAS-DNP on low-cost solid-state sources. The source projects that this would let more than 1000 NMR laboratories without funding or space for a gyrotron add DNP, with a 100X gain in signal-to-noise. Technical work includes minimizing reflected waves, which could destroy a solid-state microwave source, and tuning and matching a THz cavity in a cold MAS-DNP probe. The period of performance runs through August 31, 2029. Work is performed in Columbia, South Carolina 29229. The source identifies no sub-recipients. The assistance type is a grant.
Description
Low-loss bidirectional THZ couplers to enable affordable MAS-DNP-NMR abstract transformational advances for solid-state NMR (SSNMR) are crucial for both structural biology research, biomedical research in general, and for progress in curing alzheimer's disease, cancer, and other diseases involving cell cycle regulation and signal pathways. The critical importance of SSNMR was demonstrated, for example, by yielding the first atomic-resolution structures of the a40 and a42 amyloid fibrils that play a crucial role in alzheimer's disease (ad). Key to that structure determination was a technique denoted as dynamic NU- clear polarization (DNP) with magic angle spinning (MAS). Despite the potential of MAS-DNP, its adoption rate has been limited. All high-field (>11 T) MAS-DNP systems thus far require the level of microwave power that is only avail- able from expensive gyrotrons. Many crowded NMR laboratories do not have space to accommodate a gyrotron. Moreover, gyrotrons have a narrow bandwidth, so current-art MAS-DNP requires an NMR magnet with super- conducting sweep coils. Thus, directly and indirectly, gyrotrons add $2-9M to the system cost, and current DNP methods are limited by the poor frequency agility of gyrotrons. Only 1-9% the incident microwave power is dissipated within the lossy sample in the best published MAS- DNP designs thus far. However, novel designs that incorporate cavities will allow much more efficient use of available microwave power. That combined with ultra-low-temperature operation will enable MAS-DNP using low-cost solid-state sources, allowing 1000+ NMR labs that do not have funding or space to accommodate a gyrotron to add DNP to their tool mix with its 100X gain in S/N. Such, however, would require a means to minimize the reflected wave, which otherwise could quickly destroy a solid-state microwave source. Tuning and matching a THZ cavity in a cold MAS-DNP probe requires a low-loss high-directivity HE11 bidirectional coupler (BDC), and such are not available. Available bdcs have ~6 DB loss at 328 GHZ. Using such would mean throw- ING away 75% of available microwave power, which would render high-field DNP impossible with solid-state sources for the foreseeable future. The phase I demonstrated novel high-directivity THZ bdcs from 270-370 GHZ with loss below 1 DB and directivity an order-of-magnitude higher than reported for any prior HE11 coupler. This proposed phase-II will test the phase-I couplers, driven by a 90-MW 328-GHZ source, on a modified ultra-low-temperature (ULT) DNP probe that is under development under a separate effort. The phase-II will also develop and test low-loss high-directivity bdcs and other associated low-loss THZ components for the other common DNP frequencies from 197 GHZ to 527 GHZ. IT is expected that these novel THZ bdcs, in combination with several other technological advances being pursued in other projects, will enable MAS-DNP to be added to existing SSNMR high-field systems without the requirement of either a specialized magnet or a gyrotron and thus will make IT affordable for most SSNMR research groups. In addition, the availability from this project of enabling THZ bdcs and low-reflectivity HE11 launchers and power sensors will have a far reaching transformative impact on the broader THZ field.
Quick answers
Who received award R44GM156167?
R44GM156167 was awarded to Doty Scientific Inc. by National Institute of General Medical Sciences (National Institutes of Health) on September 7, 2026.
How much is award R44GM156167 worth?
$994,403 has been obligated on R44GM156167.
On GovTribe
See this award's full record
- Every transaction and subaward
- The recipient's other awards and teaming partners
- Similar grant awards
- Ask GovTribe AI about this award