For other functions contractor shall replace existing ceiling cove, cold cathode (2) lamp strip fixtures to new fluorescent (2) lamp strip fixtures in the following judges chamber rooms: judges smith:…
Ended Purchase Order Awarded Last action
- Contract number
- GS09P13WPM0008
- Awardee
-
Williams & Maher, Inc. UEI UW5AM98EMFM3
- Awarding agency
-
Region 9
Public Buildings Service, General Services Administration
- Obligated
- $22,500
Award facts
- Contract value 100% obligated
- $22,500.00 Current and potential, with all options
- Completion date 100% complete
- Current and potential, with all options
- Funding agency
- Administrative Office of the U.S. Courts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Set-aside
- No set-aside
- Competition
- Competed under SAP · 3 offers Simplified Acquisition
- Pricing
- Firm Fixed Price
- Place of performance
- Santa Ana, CA 92701, USA
- Legislative mandates
-
- Davis-Bacon Act FAR subpart 22.4
Award details come from SAM.gov/FPDS.
Transactions
| Action | Obligated | Date |
|---|---|---|
| Other Administrative Action | $0 | |
| Original award | $22,500 |
Description
For other functions contractor shall replace existing ceiling cove, cold cathode (2) lamp strip fixtures to new fluorescent (2) lamp strip fixtures in the following judges chamber rooms: judges smith: 5041, 5043 and 5047 judge albert: 5086, 5088, and 5092 judge clarkson: 5131, 5133 and 5137 judge bauer: 5166, 5168 and 5172 2. Contractor to rework all fixtures ballasts/replace and wiring to fixtures to be used with new fluorescent lighting. Each room will be rewired from the existing cold cathode ballast wiring to the new 120 volt wiring needed for the new fluorescent fixtures. Contractor shall utilize (2) lamp strip fixtures at various lengths (8',4',3',2') for a proper fit at ceiling lighting cove. 3. Contractor shall furnish and install all hardware, brackets, supports, etc. Necessary for a complete installation of all work. 4. All work shall be done in accordance with the national electric code (NEC) and with local governing codes. 5. All wiring shall be installed in electrical metallic tubing (EMT) conduit. 6. Any damages to adjacent surfaces or other materials caused by the contractor's work shall be satisfactorily replaced. 7. Working hours: all work to be completed after normal business hours or weekends. Access at other than the noted, shall be through prior arrangements between the contractor and the COR and the agency contact. 8. Contractor to develop project schedule for the government's approval.
Quick answers
Who was awarded contract GS09P13WPM0008?
GS09P13WPM0008 was awarded to Williams & Maher, Inc. by Region 9 (Public Buildings Service) on December 20, 2012.
How much is contract GS09P13WPM0008 worth?
The government has obligated $22,500 on GS09P13WPM0008.
Which agency awarded contract GS09P13WPM0008?
Region 9 (Public Buildings Service) awarded GS09P13WPM0008, with funding from Administrative Office of the U.S. Courts.
Was contract GS09P13WPM0008 competed?
The extent of competition for GS09P13WPM0008 was competed under sap. The government received 3 offers.