Trace matters scientific LLC proposes to design, develop, and prototype a miniature ambient desorption, ionization, and extraction source (MADIE) as a compact all-in-one instrument for operation under…
Ended Training Grant Awarded Last action
- Contract number
- 80NSSC18K0207
- Awardee
-
Trace Matters Scientific LLC UEI WT5JQNJFD7J9
- Awarding agency
-
Shared Services Center
National Aeronautics and Space Administration
- Obligated
- $32,799
Award facts
- Contract value 100% obligated
- $32,799.15 Current and potential, with all options
- Completion date 100% complete
- Current and potential, with all options
- NAICS code
- Not on record
- Set-aside
- No set-aside
- Competition
- Full and Open Competition Basic Research
- Pricing
- Other
- Place of performance
- Houston, TX 77002, USA
Award details come from SAM.gov/FPDS.
Transactions
| Action | Obligated | Date |
|---|---|---|
| Funding Only Action | -$0 | |
| Other Administrative Action | $0 | |
| Original award | $32,800 |
Description
Trace matters scientific LLC proposes to design, develop, and prototype a miniature ambient desorption, ionization, and extraction source (MADIE) as a compact all-in-one instrument for operation under the ambient martian environment to sequentially desorb, ionize, and extract analytes from martian samples. The MADIE will enable in situ interrogation of the martian mineralogical samples with no sample preparation and/or separation when coupled to a mass spectrometer. At the core of the proposed MADIE will be a self-tuning plasma ionization module for sample ionization, consisting of an ambient carbon dioxide plasma source and a tuning circuit; an ION funnel module for efficient ION extraction; and a laser diode module for time resolved sample desorption. The ambient plasma source will utilize the martian atmosphere, which is mainly composed of carbon dioxide, to form a reduced pressure carbon dioxide inductively coupled plasma (ICP) to ionize the plume of sampled analytes. The tuning circuit will compensate any plasma variation and maintain the plasma source at resonance during operation. The ION funnel module, which will be derived by a radio frequency power supply, will efficiently extract the ions and guide them into the mass spectrometer to increase sensitivity. The laser diode module will produce a plume of sample analytes from the sample surface with high spatial resolution at both ultraviolet (UV) and infrared (IR) wavelengths. During phase I, the self-tuning plasma ionization module will be designed and constructed, and the ION funnel will be designed and simulated with simion and then prototyped. Commercially available laser modules at various wavelengths will be selected and experimentally validated. These modules will then be pieced together to develop a breadboard prototype of the MADIE by the conclusion of phase I. Preliminary experiments will be conducted to test the efficiency of the MADIE.
Quick answers
Who was awarded contract 80NSSC18K0207?
80NSSC18K0207 was awarded to Trace Matters Scientific LLC by Shared Services Center (National Aeronautics and Space Administration) on November 28, 2017.
How much is contract 80NSSC18K0207 worth?
The government has obligated $32,799 on 80NSSC18K0207.
Was contract 80NSSC18K0207 competed?
The extent of competition for 80NSSC18K0207 was full and open competition.
On GovTribe
See this award's full record
- Every transaction and funding action
- The awardee's other awards and teaming partners
- Similar awards and recompete opportunities
- Ask GovTribe AI about this award