100%
Skip to main content
Platform
GovTribe AI
AI-powered insights to accelerate your government contracting workflow.
MCP Server
Connect GovTribe to your AI tools.
Beacon
Find and connect with key government decision-makers.
Profiles
Federal Agencies
Federal Contract Vehicles
Federal Grant Programs
Major Defense Acquisition Programs
NAICS Categories
PSC Categories
States
Jurisdictions
NIGP Categories
UNSPSC Categories
Vendors
Enrichment By Clearbit
Reports
New Entrants
Funding Analysis
Vehicle Analysis
Groups
Capture
Pipelines
Pursuits
Alerts
Teaming
Data
Awards
Forecasts
Federal Opportunities
State & Local Opportunities
Files
Prime and Subcontractors
Activity
Search
Exports
Solutions
Use Case
Opportunity Identification
Capture Management
Competitive Intelligence
Teaming & Partner Identification
Proposal Management
Strategic Leadership
Go-to-Market Strategy
Industry
Federal Contractors
State & Local Contractors
Grant Seekers
Government Agencies
Research & Consulting
Pricing
More
About Us
Features
Get A Demo
Sign Up
Blog
User Guide
Data Model
GovTribe for Agents
Login
Contact sales
Try for free
Login
Contact sales
Try for free
All Federal Contract Awards
Definitive Contract W9128F09C0042
Award Date
9/15/09
Potential Completion Date
5/10/11
Potential Value
$8.7M
Overview
Contacts
Activity
22
Transactions
22
Subawards
Opportunity Stack
Similar Awards
Federal Agency
ENDIST Omaha
Awardee
Bison Constructors Inc. FBJKEU5EK5P5
Ultimate Awardee
Not listed
NAICS Category
236220 - Commercial and Institutional Building Construction
PSC Category
Y299 - Contruct/All Other Non-Bldg Facs
Federal Contract Vehicle
Not listed
Set-Aside Type
Total Small Business
Extent Competed
Full and Open Competition after exclusion of sources
Major Defense Program
Not listed
Pricing Type
Firm Fixed Price
Place of Performance
Fort Hood, TX 76544, USA
Solicitation Procedures
Negotiated Proposal / Quote
Number Of Offers Received
10
Legislative Mandate
Davis Bacon Act
National Interest Action
Not listed
Research Type
Not listed
Primary Consortia Member
Not listed
Update #1
Update #2
M - JAGC, FT. HOOD, TEXAS - PROJECT NO:32078
Posted 9/15/09
5
1
Name
Description
Solicitation Number
FederalAgency
Type
PostedDate
Joint Air Ground Center, Ft. Hood, Texas
Added: Jun 19, 2009 10:55 am SOLICITATION NO. W9128F-09-R-0070On or about 10 July 2009, this office will issue Request for Proposals for construction of the Joint Air Ground Center (PN: ACC093010), Fort Hood, TX. The solicitation will close on or about 14 August 2009. This solicitation is RESTRICTED TO SMALL BUSINESS PARTICIPATION.The North American Industry Classification System code for this project is 236220 with a size standard of $33,500,000 in average gross annual receipts for the past 3 fiscal years.A site visit date will be scheduled and shown in the RFP documents. See Section 00 21 00, Paragraph SITE VISIT for a listing of date, time, place of assembly and required paper work to access Fort Hood. See Obtaining Solicitation Documents below.Project Description (Approximate Quantities):This is a Fully-Designed Project. The work consists of constructing a 37,000 SF two-story facility for the 9th Air Support Operations Squadron located at Fort Hood, TX. The Joint Air Ground Center will consist of the following building materials and site work:The new Joint Air Ground Center will provide administrative offices, training and operations offices, assembly area, telecommunications, storage, showers and locker rooms, and vehicle and radio maintenance work areas. Structure will consist of spread footings, slab on grade, metal framing, cast-in-place and CMU bearing walls, metal decking, open web steel joist, rigid insulation and SSMR. Architectural exterior will have face brick, translucent fiberglass panels, precast sills, glazing and hollow metal doors with metal frames and overhead coiling doors. Architectural interior will contain metal studs, gypsum wallboard and acoustical batt insulation, ACT, lighting fixtures, paint, tile, carpet and trim work. Interior mechanical will include general plumbing, HVAC, EMCS, fire suppression, compressed air systems, and ventilation systems. Interior electrical power will include electrical service to panels for building use on lighting fixtures, outlets and alarms. Communications work will require fiber optics and copper for LAN and phone. Site work includes clearing and grubbing, grading, asphalt and concrete for parking lots and HUMVEE hardstand area, exterior lighting, gas, water, transformers, underground electrical, and communications (fiber and copper). Vehicle hardstand area will include 52 vehicle parking stalls with enclosed storage units (approx. 100 SF w/block and LWC precast roof)) for each vehicle. HUMVEE parking will consist of 260 SF parking stall in front of each storage unit. Units will have overhead coiling doors. Overall vehicle storage units and parking stalls will be covered with a separate metal roofing system. RFP Evaluation CriteriaFirms participating in the solicitation will submit technical requirements in accordance with Section 00 22 00: PROPOSAL SUBMISSION REQUIREMENTS, INSTRUCTIONS AND EVALUATION. Submissions will be evaluated based on a best value approach considering technical elements for evaluation (i.e., Construction Experience, Construction Past Performance and Key Construction and Design Personnel). An adjectival method of evaluation will be used to evaluate all technical factors. Price will be evaluated separately for reasonableness and realism. A Best Value will be considered after reviewing technical factors and price.The estimated construction cost of this project is between $7,500,000 and $10,000,000.Bidders (Offerors): Please be advised of on-line registration requirement in Central Contractor Registration (CCR) database http://www.ccr.gov/ and directed solicitation provisions concerning electronic annual On-line Representations and Certifications (ORCA) at http://orca.bpn.gov. Representations and certifications are required to be updated annually as a minimum to keep information current, accurate and complete. The electronic annual representations and certifications are effective until one year from date of submission or update to ORCA.Obtaining Solicitation Documents: Solicitation documents will be posted to the web via Federal Business Opportunities (www.fbo.gov). Registering is required to access solicitation documents. Federal Business Opportunities provides secure access to acquisition-related information, synopsis or pre-solicitation notices and amendments. Summary of access requirements to solicitations is as follows:1. Find solicitation announcement in Fed Biz Opps (www.fbo.gov)2. If you are a first time user, you will have to register** (see info included below); Otherwise, enter username and password. 3. Click on Opportunities hyperlink at top of the fbo.gov.4. Enter solicitation number of project in Keywords/SOL # box and click on Go button.5. Click on link to solicitation or amendment.6. If you want other vendors, sub-contractors or contractors to contact you, click on Add me to Interested Vendors link. 7. Click on Packages link.8. To access solicitation documents, Central Contractor Registration Marketing Partnering Identification Number (MPIN) and solicitation number are required. Click on Go button. Follow the on-screen requirements to access and download the solicitation documents or amendments.**Registration: The information listed below is required to register.1. Central Contractor Registration (CCR) Marketing Partner Identification Number (MPIN)2. DUNS Number or CAGE code3. Telephone Number4. E-Mail address
W9128F09R0070
Department of the Army Corps of Engineers Engineering District Omaha
Award Notice 1/1
6/19/09, 10:55 AM
5
1
2
3
4
5
Mod #
Description
ReasonForModification
Federal Obligation
Date
A00019
CONTRACT FOR CONSTRUCT A JOINT AIR GROUND CENTER PN093010 AT FORT HOOD, TEXAS. REFERENCE NO. R00021 MG051 CHILLER HAIL GUARDS - COR #62 SEE PAGE 2. A. SCOPE OF WORK MG051 CHILLER HAIL GUARDS - COR #62 FURNISH AND INSTALL HAIL GUARDS ON THE CHILLER (CH-1) TO PROTECT THE EXPOSED RADIATORS.
Supplemental Agreement for work within scope
$3.6k
5/18/11
A00018
CONTRACT FOR CONSTRUCT A JOINT AIR GROUND CENTER PN093010 AT FORT HOOD, TEXAS. REFERENCE NO. R00020 MG050 RELOCATION OF CONDENSER ACCU-1 - COR 66 SUMMARY OF CHANGES A. SCOPE OF WORK: MG050 RELOCATION OF CONDENSER ACCU-1 - COR 66 PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY TO PERFORM THE FOLLOWING SCOPE OF WORK: MECHANICAL WORK 1) REMOVE ACCU-1 FROM OUTSIDE, CAP AND SEAL PIPING JUST ABOVE SLEEVE. INSTALL A METAL COVER OVER TOP OF SLEEVE AND CAULK AND SECURE. 2) INSIDE MECHANICAL ROOM, CAP AND SEAL PIPING JUST ABOVE SLEEVE. INSTALL A METAL COVER OVER TOP OF SLEEVE, CAULK AND SECURE. 3) REMOVE REFRIGERANT PIPE FOR AC 1, 2, 3 FROM RACK GOING UP WALL AND OVER THE TOP OF AHU-1. 4) RELOCATE AND INSTALL ACCU-1 INSIDE THE MECHANICAL ROOM ON THE FAR SIDE OF AHU-1, JUST BELOW THE CHASE TO SECOND FLOOR. A. SUPPLY DUCT PLENUM. (SEE ATTACHMENT A). B. THE UNIT WILL FIT IN SIDEWAYS WITH SUCTION SIDE NEAR WALL SEPARATING MECHANICAL ROOM AND ROOM NUMBER 114. C. DISCHARGE WOULD PARALLEL AHU-1 AND NON SERVICE SIDE WOULD FACE HALLWAY WALL. D. THIS WOULD ALLOW FOR FULL ACCESS AND MEET ALL MINIMUM CLEARANCES. (SEE ATTACHMENT D). 5) INSTALL ACCU-1 ON TOP OF 36" TALL ANGLE FRAME STAND BOLTED TO FLOOR WITH UNIT BOLTED TO STAND THREW DRAIN PAN. (SEE ATTACHMENT B). 6) INSTALL DRAIN PAN ON TOP OF FRAME UNDER UNIT AND RUN DRAIN LINE OUT SIDE UNDER AHU-1 DUCT WORK TO FLOOR DRAIN. (SEE ATTACHMENT C). 7) RECONNECT REFRIGERANT LINES IN NEW LOCATION TO CURRENT REVISED PIPE AT CHASE BOTTOM. INSTALL WITH SOFT COPPER AND LARGE RADIUS BENDS. 8) FURNISH AND INSTALL A 6" SPIRAL DUCT TAPPED INTO EF-3, JUST OVER THE TOP OF AHU-1. RUN DOWN JUST IN FRONT ABOVE ACCU-1 DISCHARGE SIDE AND TERMINATED WITH A SCREEN. 9) RESET CFM MAX COOL SET POINT ON VAV 1-08 TO 1350 CFM TO COMPENSATE FOR HEAT LOAD INCREASE. 10) INSULATE LINES AS REQUIRED PER SPECIFICATIONS. ELECTRICAL WORK 1) FURNISH AND INSTALL NEW POWER AND CONTROL WIRE TO NEW CONDENSER LOCATION PER SPECIFICATIONS. 2) REMOVE AND DISPOSE OF ABANDONED ELECTRICAL SERVICE.
Supplemental Agreement for work within scope
$14.7k
4/20/11
A00017
CONTRACT FOR CONSTRUCT A JOINT AIR GROUND CENTER PN093010 AT FORT HOOD, TEXAS.REFERENCE NO. R00019MG043ADDITIONAL FIRE HYDRANT PER FHFDMG046-1REVISION TO DETAIL C3/A-511 - COR 60MG046-2LOUVERS NOT INCLUDED IN BID - COR 61MG047-1EXT. WIRING CREDIT - COR-63MG047-2ADDED SPRINKLER HEADS PER FM COR #54MG048-1BRACKETS TO SUPPORT 28V DC EQUIP - COR64- PROJECT NO:32078 A. SCOPE OF WORK MG043 ADDITIONAL FIRE HYDRANT PER FHFD FURNISH AND INSTALL ONE (1) ADDITIONAL FIRE HYDRANT. (1) PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY TO COMPLETE THIS SCOPE OF WORK. (2) PROVIDE ALL EXCAVATION, BACKFILL, SITE RESTORATION, SEEDING AND MULCHING. (3) PROVIDE ALL NECESSARY TESTING AND DISINFECTION PER AMERICAN WATER STANDARDS. (4) ALL PIPING MATERIALS AND THE HYDRANT INSTALLED ARE TO MEET OR EXCEED AMERICAN WATER SPECIFICATIONS. (5) ANY DAMAGE DONE TO THE EXISTING UTILITIES OR PARKING LOT, WHILE COMPLETING THIS SCOPE OF WORK, WITH BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE GOVERNMENT. (6) DELETE TWO (2) EACH PARKING SPACES AS SHOWN ON THE ATTACHED SKETCH. PAINT DIAGONAL LINES THROUGH SPACES. (7) SEE ATTACHED SKETCH SK-MG043 FOR ADDITIONAL INFORMATION. MG046-1 REVISION TO DETAIL C3/A-511 - COR 60 IN LIEU OF INSTALLING THE L3X3X3/16 ANGLE CLIPS AS SHOWN ON DETAIL C3/A-511, PROVIDE L6X4X5/16 ANGLE CLIPS. MG046-2 LOUVERS NOT INCLUDED IN BID - COR 61 FURNISH AND INSTALL ALL LOUVERS AS INDICATED ON THE "M" SHEETS. MG047-1 EXT. WIRING CREDIT - COR-63 PROVIDE CREDIT FOR USING TYPE THHN WIRE FOR EXTERIOR AND BELOW GRADE WIRING INSTEAD OF USING XHHN WIRE AS SPECIFIED. MG047-2 ADDED SPRINKLER HEADS PER FM COR #54 FURNISH AND INSTALL TWO (2) EACH, ADDITIONAL FIRE SPRINKLER HEADS IN THE SOFFIT ABOVE THE NORTH ENTRANCE TO ROOM 210. MG048-1 BRACKETS TO SUPPORT 28V DC EQUIP - COR64 FURNISH AND INSTALL BRACKETS, SIMILAR THOSE USED TO SUPPORT THE INTERIOR TRANSFORMERS, TO SUPPORT THE 28V DC GENERATORS USED IN THE MAINTENANCE BAY. TWO LOCATIONS TYPICAL. MG048-2 PROVIDE PWR FEED TO FP CONTROLLER- COR65 FURNISH AND INSTALL A POWER FEED TO THE FIRE PUMP CONTROLLER. PROVIDE DEDICATED LINE FROM PANEL P1A. MG049THIRTY (30) DAY CONTRACT EXTENSION THE CONTRACT COMPLETION DATE FOR THIS CONTRACT HAS BEEN EXTENDED 30 DAYS. THE REVISED COMPLETION DATE IS NOW 10 MAY 2011.
Supplemental Agreement for work within scope
$22.3k
4/12/11
A00016
CONTRACT FOR CONSTRUCT A JOINT AIR GROUND CENTER PN093010 AT FORT HOOD,TX.REF R00018 MG044-1GLASS FOR MID DOOR TRANSOMS - COR #47MG044-2CHANGES PER COORD. STUDY - COR #50MG044-3POWER TO HEAT TRACE RFI 144 - COR #53MG044-4POWER TO AUTOMATIC LAV FAUCETS - COR #55MG044-5 MISCELLANEOUS POWER FEEDS - COR 56RMG044-6REVISED SPRNET ROUTING - COR 57 A. SCOPE OF WORK
Supplemental Agreement for work within scope
$1.7k
3/23/11
A00015
TAS::57 3300::TAS:: CONTRACT FOR CONSTRUCT A JOINT AIR GROUND CENTER PN093010 AT FORT HOOD, TEXAS. REFERENCE NO. R00017 MG040STAIRWELL FIRE RATING WORK MG041-1 ELECTRICAL FEED TO DDC CABINET (COR 44) MG041-2 ELECTRICAL FEED TO ELEV. SHUNT (COR 45) MG041-3 PWR FEED TO RELIEF FAN ON AHU (COR 46R) A. SCOPE OF WORK MG040 STAIRWELL FIRE RATING WORK PER THE ATTACHED SKETCHES (#1 - #8, DATED 12/1/10) FROM LEO DALY, PERFORM THE FOLLOWING WORK ASSOCIATED WITH ESTABLISHING THE REQUIRED ONE HOUR FIRE RATING IN THE NORTH AND SOUTH STAIRWELLS. 1) FURNISH AND INSTALL ALL LIGHT GAUGE METAL FRAMING, DRYWALL, TAPING AND PAINTING AS INDICATED OR REQUIRED. 2) FURNISH AND INSTALL ALL SHAFT WALL SYSTEMS AS INDICATED OR REQUIRED. 3) FURNISH AND INSTALL ALL INTUMESCENT PAINTING AS REQUIRED. 4) PROVIDE ALL HVAC, SPRINKLER, AND ELECTRICAL MODIFICATIONS AS INDICATED. 5) FURNISH AND INSTALL ALL MINERAL WOOL AND FIRE SEALING AS INDICATED OR REQUIRED. 6) FURNISH AND INSTALL ALL SHEET METAL ANGLES AS INDICATED OR REQUIRED. 7) MODIFY EXISTING METAL STUD WALL FRAMING AS INDICATED. MG041-1 ELECTRICAL FEED TO DDC CABINET (COR 44) FURNISH AND INSTALL A NEW ELECTRICAL CIRCUIT FROM ELECTRICAL PANEL P1A TO THE DDC CABINET PER THE RESPONSE FROM AE TO RFI #132 TO PROVIDE POWER TO THE CABINET. MG041-2 ELECTRICAL FEED TO ELEV. SHUNT (COR 45) FURNISH AND INSTALL A NEW ELECTRICAL CIRCUIT FROM ELECTRICAL PANEL P1A TO THE SHUNT TRIP IN THE ELEVATOR MACHINE ROOM TO PROVIDE POWER TO THE SHUNT TRIP AND MEET THE REQUIRED TEXAS STATE ELECTRICAL CODE. MG041-3 PWR FEED TO RELIEF FAN ON AHU (COR 46R) FURNISH AND INSTALL A NEW ELECTRICAL CIRCUIT FROM THE RELIEF FAN LOCATED ON AHU-1 TO THE CLOSEST AVAILABLE ELECTRICAL PANEL TO PROVIDE POWER TO THE FAN.
Supplemental Agreement for work within scope
$41.7k
1/6/11