100%
Skip to main content
Platform
GovTribe AI
AI-powered insights to accelerate your government contracting workflow.
MCP Server
Connect GovTribe to your AI tools.
Beacon
Find and connect with key government decision-makers.
Profiles
Federal Agencies
Federal Contract Vehicles
Federal Grant Programs
Major Defense Acquisition Programs
NAICS Categories
PSC Categories
States
Jurisdictions
NIGP Categories
UNSPSC Categories
Vendors
Enrichment By Clearbit
Reports
New Entrants
Funding Analysis
Vehicle Analysis
Groups
Capture
Pipelines
Pursuits
Alerts
Teaming
Data
Awards
Forecasts
Federal Opportunities
State & Local Opportunities
Files
Prime and Subcontractors
Activity
Search
Exports
Solutions
Use Case
Opportunity Identification
Capture Management
Competitive Intelligence
Teaming & Partner Identification
Proposal Management
Strategic Leadership
Go-to-Market Strategy
Industry
Federal Contractors
State & Local Contractors
Grant Seekers
Government Agencies
Research & Consulting
Pricing
More
About Us
Features
Get A Demo
Sign Up
Blog
User Guide
Data Model
GovTribe for Agents
Login
Contact sales
Try for free
Login
Contact sales
Try for free
All Federal Contract Awards
Definitive Contract W52P1J14C5007
Award Date
6/9/14
Potential Completion Date
8/25/14
Potential Value
$292K
Overview
Contacts
Activity
1
Transactions
1
Subawards
Opportunity Stack
Similar Awards
Funding Federal Agency
Southwest Region
Contracting Federal Agency
Joint Munitions Command
Awardee
JIM Giese Commercial Roofing Inc. NEYFK5AKKV15
Ultimate Awardee
Not listed
NAICS Category
238160 - Roofing Contractors
PSC Category
5650 - Roofing And Siding Materials
Set-Aside Type
Total Small Business
Federal Contract Vehicle
Not listed
Extent Competed
Full and Open Competition after exclusion of sources
Major Defense Program
Not listed
Pricing Type
Firm Fixed Price
Place of Performance
Rock Island, IL 61299, USA
Solicitation Procedures
Negotiated Proposal / Quote
Number Of Offers Received
8
Legislative Mandate
Davis Bacon Act
National Interest Action
Not listed
Research Type
Not listed
Primary Consortia Member
Not listed
Description
RE-ROOF BUILDING 107
Posted 5/23/14
5
1
Name
Description
Solicitation Number
FederalAgency
Type
PostedDate
Re-roofing building 107 at Rock Island Arsenal, Rock Island, IL
Added: Feb 25, 2014 11:56 am This pre-solicitation synopsis is notice regarding solicitation W52P1J-14-R-5005 for re-roofing building 107 at the Rock Island Arsenal, Rock Island, IL. This requirement will be a total small business set aside, NAICS code 238160. This solicitation is expected to be posted on or around March 11, 2014. Work includes re-roofing approximately 21,000 square feet, focusing on complete demolition, removal of all debris and replacement of entire existing roofing assembly with installation of a new complete roofing assembly (roof insulation, roof boards, fully adhered, single ply Ethylene Propylene Diene Monomer (EPDM) roofing membrane, all required flashing/counter-flashing, and roof drains) on the main and low roof sections of building 107. The entire existing roofing system is to be removed and replaced with a complete new single ply 60 mil. EPDM roofing assembly. Contractor shall establish a complete water tight roofing system as an integral part of the base project bid. Work will include providing new flashing and counter-flashing, per roofing manufactures details and specifications, at all existing roof ventilation devices, all similar tough roof penetrations, curbs and parapet walls, adjacent wall surfaces, all riglet devices and at any construction or expansion joints. Included in the base project is removal of all existing tapered roof insulation and quote mark roof boards, and their replacements and new quote mark roof boards (Dens-Deck or approved equal) and new tapered isocyanurate (ISO) insulation (3 quote mark min. thickness). The new tapered ISO insulation boards and roof boards will have to be adhered to the roof structure per the roofing system manufactures details and recommendations. The installed, new tapered insulation boards will have to maintain a minimum 1/8 quote mark per foot slope to the new roof drains. Several pieces of active ACC/HVAC equipment (3), various piping runs, a satellite dish, numerous curbs, etc. are presently installed on building 107's roofs. It is the Contractor's responsibility to raise, dismount/remount and accommodate any such existing equipment or obstructions, as necessary, to assure the final water tight integrity of the new roofing system assembly installation. Work will include any replacement and/or repair of the existing structural wood decking material (installed over the former sky light openings in the concrete roof decking), found to be damaged or deteriorated after removal of the existing roof assembly. Replacement and/or repair of the existing structural concrete roof decking material found to be damaged or deteriorated after removal of the existing roofing assembly. Work will also include the removal and replacement of all existing roof drains and any curbs found to be damaged or deteriorated after removal of the existing roofing assembly. Contractor will supply and install two steel roof access ladders. Contractor shall provide all services, labor, materials, supervision, equipment, tools, etc. necessary to accomplish the work described in this Scope of Work (SOW). The above noted square footage of existing roof area to be repaired is included only to provide the Contractor with a general, order of magnitude idea as to the approximate scale of the project. The Contractor is solely responsible for the accuracy of all necessary material take-offs, measurements and calculations necessary to accommodate the requirements of this project that will be described in a SOW. The Contractor shall be required to complete the entire work and have it ready for use not later than 75 days after award of contract. The roofing design and construction shall be in accordance with the current edition of the United Facilities Criteria (UFC) 3-110-03: Roofing, the Rock Island Arsenal Installation Design Guide (RIA IDG) Appendix T-Engineering Standards and the RIA Master Specifications. Contractor shall comply with RIA-DWP Master Specifications pertaining to this project, in particular, Elastomeric Roofing (EPDM) Specification 07530. The applicable codes and standards shall include, but not be limited to those indicated in the UNIFIED FACILITIES CRITERIA (UFC): 1-200-01 GENERAL BUILDING REQUIREMENTS, dated 16 August 2010, including revisions 28 November 2011. This documents can be found at the following internet site: http://www.wbdg.org/ccb/DOD/UFC/ufc_1_200_01.pdf
W52P1J14R5005
Department of the Army Materiel Command Joint Munitions Command
Award Notice 1/1
2/25/14, 11:56 AM
5
1
Mod #
Description
ReasonForModification
Federal Obligation
Date
Not listed
RE-ROOF BUILDING 107
Not listed
$291.9k
5/23/14