Construction of BAY pines inpatient outpatient improvements, mental health addition at BAY pine, VAMC, project no. 516-005 obli# CO 516X10518

Ended Definitive Contract Awarded Last action

Contract number
VA101CFMC0139
Awardee
Awarding agency
Obligated
$109,327,964

Award facts

Opportunity
Contract value 100% obligated
$109,327,964.00 Current and potential, with all options
Completion date 100% complete
Current and potential, with all options
Contracting staff
Set-aside
No set-aside
Competition
Full and Open Competition · 10 offers Negotiated Proposal / Quote
Pricing
Firm Fixed Price
Place of performance
Bay Pines, FL 33744, USA
Legislative mandates

Award details come from SAM.gov/FPDS.

Transactions

Action Obligated Date
Supplemental Agreement for work within scope P00390 · Settlement of bonding and PCI 5588 credit $82,379
Supplemental Agreement for work within scope P00389 · Settlement of claim numbers 6 and 7 $6,975,000
Supplemental Agreement for work within scope P00388 $3,525,000
Supplemental Agreement for work within scope P00387 · Misc masonry changes with three pcis are bundled to resolve in this modification action. Pcis 5168, 5353,5462 are resolved. $12,885
Supplemental Agreement for work within scope P00386 · Misc. Small changes are bundled that resolves PCI 5374.1, PCI 5416, PCI 5223, PCI5211, PCI 5428. For PCI 5374.1- CO P00202 was issued for $3,266 which is… $15,094
Supplemental Agreement for work within scope P00385 · Add power for dock leveler and scissor lift at MHA loading dock and lighting on the loading dock associated with RFI 5253. Refer to drawing EL 101-4 and EP… $30,000
Supplemental Agreement for work within scope P00383 · This modification P00383 definitizes P00097 for the ceiling height revisions in the CEP as detailed in ASI-003D $33,302
Supplemental Agreement for work within scope P00381 · Add ramp at CEP generator building, at dining courtyard. Install powder coated handrails. $50,687
Supplemental Agreement for work within scope P00373 · Changes per ASI-003G which included demo existing CEP precast. A unilateral change order P00099 was issued so the contractor could performed the work while… $30,783
Supplemental Agreement for work within scope P00372 · Alteration and modification to storm drain system and roofing system directed by RFI 5698. This modification definitizes unilateral modification P00300. $5,000
Supplemental Agreement for work within scope P00382 · The original contract documents showed 2 separate steam condensate pipes going from the new MHA to the existing condensate receiver in the CEP. There was not… $1,400
Supplemental Agreement for work within scope P00379 · This modification is for the resolution of pcis 5382, 5452, 5512, 5564 and 5591. The work includes -concrete piers at pedway footing, revision of pedway… $78,542
Supplemental Agreement for work within scope P00380 · Provide IT tririga support from contractor to the SRE office due to the VA change in online systems not provided for in the contract. $22,757
Supplemental Agreement for work within scope P00378 · This bilateral agreement definitizes P00189 with the remaining amount of $665 for providing surveying services to determine the height of tower cranes on the… $665
Supplemental Agreement for work within scope P00377 · This supplemental agreement definitizes P00182 to cover the remaining cost of $3,506 for changes to the EJ at gridline 22.8 between P.7 and P.9 $3,506
Supplemental Agreement for work within scope P00376 · Provide additional fire pump churn tests requested by SEM as noted in PCI-5541R2 and delete fire pump testing requirements.as noted in PCI-5563. -$7,700
Supplemental Agreement for work within scope P00375 · The following pcis have been negotiated, some definitized from unilateral to included in this modification PCI 5106,5322, 5389, 5398, 5418, 5508. $45,640
Change Order P00374 · RFQ-012 was issued for the deletion of eight balancing valve per RFI-0669 and PCI 5592 is to provide power for temperature sensors required for balancing valves… $0
Supplemental Agreement for work within scope P00370 · This supplemental agreement definitizes unilateral modification P00342. To compensate contractor for the additional work resulting from the commissioning… $26,035
Supplemental Agreement for work within scope P00368 · The location for the terminal cabinet D-TC1 for grounding and control wiring was not specified for connecting to automatic transfer switches and substations… $3,268
Supplemental Agreement for work within scope P00369 · Reroute and extend existing 6-inch steam safety relief valve vent piping located above the existing building 100 central energy plant to avoid conflict with new… $2,736
Supplemental Agreement for work within scope P00371 · Installation of bahama shutters at MHA $210,902
Supplemental Agreement for work within scope P00363 · Adjust the casework in room 1G-405 due to the expansion of a faux column to cover additional in wall plumbing. $1,982
Supplemental Agreement for work within scope P00367 · Delete all work necessary to tie-in the new MHA nurse call head end to the existing building 100 nurse call system. -$583
Supplemental Agreement for work within scope P00365 · Add phone line for MHA service and passenger elevators which were omitted from the contract drawings. $4,130
Supplemental Agreement for work within scope P00308 · Settlement of various pcis. $21,073
Supplemental Agreement for work within scope P00366 · To compensate contractor for additional work associated with design AE revisions included in ASI-003C and definitize unilateral modification P00096 $1,068
Supplemental Agreement for work within scope P00362 · P00362 definitizes CO P00007 for the reinforcing bldg 101 roof for support of steam pipe. $53,557
Supplemental Agreement for work within scope P00364 · SA P00364 definitizes CO P00139 PCI 5351R1 to raise existing piping to clear ceiling at CEP in room 1F-223 $2,163
Supplemental Agreement for work within scope P00361 · An enclosure around the pneumatic tube riser is required to prevent potential hazard to patients on the 3RD floor psychiatric ward. $1,934
Supplemental Agreement for work within scope P00360 · This modification resolves 11 drywall and framing-related modifications and contractor PCI proposals for various wall and soffit revisions in the mental… $72,502
Supplemental Agreement for work within scope P00359 · This modification resolves 22 electrical-related modifications and contractor PCI proposals for various electrical revisions in the mental health addition, CEP,… $44,464
Supplemental Agreement for work within scope P00358 · This modification is to blank off washer dryer plumbing fixture receptacle openings due to lack of coordination between plumbing and electrical drawings. $923
Change Order P00357 · This modification is to revise the MHA 480V life safety branch conduit riser protection originally shown as concrete due to structural issues with the weight of… $0
Supplemental Agreement for work within scope P00348 · This modification addresses revised telecom provisions resultant from adding a telecom room in the 2ND floor of the CEP, and replacing undersized existing… $2,509
Supplemental Agreement for work within scope P00355 · This modification addresses revisions to fuel oil PIT to facilitate the installation of the double wall underground piping up through the floor in the CEP. $0
Change Order P00356 · This modification is to remove sixteen (16) orifice plates and four (4) check valves from twenty locations in the CEP expansion chilled water and condenser… $44,714
Supplemental Agreement for work within scope P00352 · This modification adds precast architectural concrete (PAC) sills at the CEP and the warehouse, and revised warehouse louvers sill from solid CMU to PAC sill in… $14,660
Supplemental Agreement for work within scope P00353 · This modification adds six additional led light fixtures to increase the warehouse site lighting to meet the required lighting. $0
Supplemental Agreement for work within scope P00354 · This modification addresses the permanent rerouting of the medical gas alarm wiring to building 71 from building 101 on the new south pedway, and the revision… -$137
Supplemental Agreement for work within scope P00350 · This modification replaces two sets of double doors that were specified to be 6'-6" tall which does not meet life safety code, and swap two wood veneer doors in… $11,327
Supplemental Agreement for work within scope P00349 · There were numerous revisions of the warehouse and CEP CMU control joint locations resultant from correction of design errors and omissions. $80,264
Change Order P00333 · This modification provides further pacs and CCTV modification related to the previous SA P00268 ASI 003L revisions to connect the MHA security system to the… $33,994
Supplemental Agreement for work within scope P00345 · As a result of AE markups of the contractor's CEP rebar submittals, additional rebar requirements were added. $57,521
Supplemental Agreement for work within scope P00347 · This modification is to add a concrete curb for the omitted code provision of transformer oil containment. $2,000
Change Order P00346 · This modification addresses revised fire sprinkler monitoring requirements resultant from submittal revisions. $1,578
Supplemental Agreement for work within scope P00343 · This modification addresses the installation of additional support steel for CEP piping resultant from rfis 5164, 5184, 5203, and 5212. $28,516
Supplemental Agreement for work within scope P00344 · This modification is for several changes to the MHA courtyards including stucco and deletion of a fountain and conversion into a planter. $6,203
Change Order P00342 · This modification implements additional electrical commissioning requirements resultant from scope revisions to the original commissioning agent scope. $9,096
Supplemental Agreement for work within scope P00341 · This modification addresses revised telecom provisions resultant from adding a telecom room in the 2ND floor of the CEP, and making this room the new CEP MDF in… $3,055
Show 40 more

Latest 50 listed here. See the rest on GovTribe.

About this award

This is a $109,327,964.00 firm fixed price construction contract awarded by the VA Office of Construction and Facilities Management to Archer Western-Demaria JV 11 for the construction of improvements and a mental health addition at the Bay Pines VAMC in Florida. The contract, which does not have a set-aside designation, includes work such as inpatient and outpatient facility upgrades, as well as a new mental health wing. Major subcontractors include W.H. Reynolds Distributor, Kelley Equipment Co of Florida, Stabil Concrete Products, and others providing various construction and building services. This contract supports the VA's mission to provide high-quality healthcare facilities and infrastructure to serve the needs of veterans.

Quick answers

Who was awarded contract VA101CFMC0139?

VA101CFMC0139 was awarded to Archer Western-Demaria JV 11 by VA Office of Construction and Facilities Management (Headquarters) on March 31, 2011.

How much is contract VA101CFMC0139 worth?

The government has obligated $109,327,964 on VA101CFMC0139.

Was contract VA101CFMC0139 competed?

The extent of competition for VA101CFMC0139 was full and open competition. The government received 10 offers.

On GovTribe

See this award's full record

  • Every transaction and funding action
  • The awardee's other awards and teaming partners
  • Similar awards and recompete opportunities
  • Ask GovTribe AI about this award