JPRA White Bluff Generator Repair and Installation

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
FA462024QA105
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Spokane, Washington 99224, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This solicitation seeks generator repair and installation services at the Joint Personnel Recovery Agency White Bluff facility located in Spokane, Washington. The Department of the Air Force Air Mobility Command requires a contractor to diagnose and repair an existing 750kW generator and utilize a government furnished generator and automatic transfer switch to design, inspect, and install a standby power system for Building 35. The contractor must complete repairs to the first generator within seven days of award and have the second generator operational by March 1, 2024. Proposals are due by January 22, 2024.

The requirement is set aside as a total small business opportunity under NAICS code 811310 with a size standard of $12.5M. The contractor shall provide all labor, materials, equipment and tools required to diagnose and repair the first generator and inspect, design, and install the second generator and transfer switch at the Joint Personnel Recovery Agency White Bluff facility located in Spokane, Washington, to be completed between January and March 2024. Pricing shall be provided using the schedule included as an attachment, and the government may negotiate miscellaneous labor and parts up to $10,000 and $4,000 respectively.

Notice text

5 versions

Update #5 · Latest ·

This requirement is for the repair of GENERATOR 1 and installation services for GENERATOR 2 located at the JPRA White Bluff location in Spokane, WA. Contractor shall diagnosis and repair GENERATOR 1. Contractor shall utilize government furnished GENERATOR 2 and Transfer Switch in order to inspect, design, and install equipment for an operational stand-by power generator system for Bldg. 35 at the Joint Personnel Recovery Agency - White Bluff location (11604 W Newkirk Rd, Spokane).

Amendment 0001

The purpose of this Amendment is to:

1.  Extend the due date for proposals

2.  Update Addendum FAR 52.212-1, Instructions to Offerors– Commercial Products and Commercial Services to incorporate a change in date for the Site Visit

The due date for proposals is changed from 12 January 2024, 2:00PM PT to 17 January 2024, 2:00PM PT.

The site visit date is changed from 8 January 2024, 9:00AM PT to 11 January 2024, 9:00AM PT.

The due date for questions is changed from 9 January at 1:00PM PT to 12 January 2024, 1:00PM PT.

All changes are incorporated in attached Combo Synopsis/Solicitation FA462024QA105; changes annotated in red.

Amendment 0002

The purpose of this Amendment is to:

1. Add Attach. 1 SOW (Rev. 1) 12Jan24 JPRA White Bluff Generator Repair and Installation
2. Add Attach. 4 Questions and Government Responses

Amendment 0003

The purpose of this amendment is to:

1. Extend the due date for proposals

2. Replace Attachment 4 with 'Attach. 4 Questions and Government Responses (Rev.01_16Jan24)'

The due date for proposals is changed from 17 January 2024, 2:00PM PT to 22 January 2024, 2:00PM PT.

Amendment 0004

The purpose of this Amendment is to:

1. Update Questions and Government Answers document with additional questions [(Attach 4 Questions and Government Responses (Rev.02_17Jan24)]

Questions and answers added are as follows:

Q: Is the normal power from the pad mount transformer to the main switchboard MDP1 ran through the can that is located where the ATS with be installed?

A: Yes

Q: Is there enough existing wire to be able to reuse to hook up the ATS?

A: There is enough to connect to the ATS and a 50/50 chance that there may be enough to get back to the MDP1. It is advised to err on the side of caution with the assumption that it may need to be replaced; therefore, if there isn’t enough you are covered.

Update #4 ·

This requirement is for the repair of GENERATOR 1 and installation services for GENERATOR 2 located at the JPRA White Bluff location in Spokane, WA. Contractor shall diagnosis and repair GENERATOR 1. Contractor shall utilize government furnished GENERATOR 2 and Transfer Switch in order to inspect, design, and install equipment for an operational stand-by power generator system for Bldg. 35 at the Joint Personnel Recovery Agency - White Bluff location (11604 W Newkirk Rd, Spokane).

Amendment 0001

The purpose of this Amendment is to:

1.  Extend the due date for proposals

2.  Update Addendum FAR 52.212-1, Instructions to Offerors– Commercial Products and Commercial Services to incorporate a change in date for the Site Visit

The due date for proposals is changed from 12 January 2024, 2:00PM PT to 17 January 2024, 2:00PM PT.

The site visit date is changed from 8 January 2024, 9:00AM PT to 11 January 2024, 9:00AM PT.

The due date for questions is changed from 9 January at 1:00PM PT to 12 January 2024, 1:00PM PT.

All changes are incorporated in attached Combo Synopsis/Solicitation FA462024QA105; changes annotated in red.

Amendment 0002

The purpose of this Amendment is to:

1. Add Attach. 1 SOW (Rev. 1) 12Jan24 JPRA White Bluff Generator Repair and Installation
2. Add Attach. 4 Questions and Government Responses

Amendment 0003

The purpose of this amendment is to:

1. Extend the due date for proposals

2. Replace Attachment 4 with 'Attach. 4 Questions and Government Responses (Rev.01_16Jan24)'

The due date for proposals is changed from 17 January 2024, 2:00PM PT to 22 January 2024, 2:00PM PT.

Update #3 ·

This requirement is for the repair of GENERATOR 1 and installation services for GENERATOR 2 located at the JPRA White Bluff location in Spokane, WA. Contractor shall diagnosis and repair GENERATOR 1. Contractor shall utilize government furnished GENERATOR 2 and Transfer Switch in order to inspect, design, and install equipment for an operational stand-by power generator system for Bldg. 35 at the Joint Personnel Recovery Agency - White Bluff location (11604 W Newkirk Rd, Spokane).

Amendment 0001

The purpose of this Amendment is to:

1.  Extend the due date for proposals

2.  Update Addendum FAR 52.212-1, Instructions to Offerors– Commercial Products and Commercial Services to incorporate a change in date for the Site Visit

The due date for proposals is changed from 12 January 2024, 2:00PM PT to 17 January 2024, 2:00PM PT.

The site visit date is changed from 8 January 2024, 9:00AM PT to 11 January 2024, 9:00AM PT.

The due date for questions is changed from 9 January at 1:00PM PT to 12 January 2024, 1:00PM PT.

All changes are incorporated in attached Combo Synopsis/Solicitation FA462024QA105; changes annotated in red.

Amendment 0002

The purpose of this Amendment is to:

1. Add Attach. 1 SOW (Rev. 1) 12Jan24 JPRA White Bluff Generator Repair and Installation
2. Add Attach. 4 Questions and Government Responses

Update #2 ·

This requirement is for the repair of GENERATOR 1 and installation services for GENERATOR 2 located at the JPRA White Bluff location in Spokane, WA. Contractor shall diagnosis and repair GENERATOR 1. Contractor shall utilize government furnished GENERATOR 2 and Transfer Switch in order to inspect, design, and install equipment for an operational stand-by power generator system for Bldg. 35 at the Joint Personnel Recovery Agency - White Bluff location (11604 W Newkirk Rd, Spokane).

Amendment 01

The purpose of this Amendment is to:

1.  Extend the due date for proposals

2.  Update Addendum FAR 52.212-1, Instructions to Offerors– Commercial Products and Commercial Services to incorporate a change in date for the Site Visit

The due date for proposals is changed from 12 January 2024, 2:00PM PT to 17 January 2024, 2:00PM PT.

The site visit date is changed from 8 January 2024, 9:00AM PT to 11 January 2024, 9:00AM PT.

The due date for questions is changed from 9 January at 1:00PM PT to 12 January 2024, 1:00PM PT.

All changes are incorporated in attached Combo Synopsis/Solicitation FA462024QA105; changes annotated in red.

Update #1 ·

This requirement is for the repair of GENERATOR 1 and installation services for GENERATOR 2 located at the JPRA White Bluff location in Spokane, WA. Contractor shall diagnosis and repair GENERATOR 1. Contractor shall utilize government furnished GENERATOR 2 and Transfer Switch in order to inspect, design, and install equipment for an operational stand-by power generator system for Bldg. 35 at the Joint Personnel Recovery Agency - White Bluff location (11604 W Newkirk Rd, Spokane).

Files

Show all 15

Notice history

Notice Type Posted
JPRA White Bluff Generator Repair and Installation Award Award Notice
This notice Latest solicitation Solicitation
Sources Sought for Generator Repair Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Johnston Ridge Observatory Backup Generator Repairs Gifford Pinchot National Forest Toutle, Washington 98649, United States · NAICS 238290 Region 6 - Pacific Northwest Region Total Small Business
J061--Thompson Power Generator Service RFI Intent to Sole Source Department of Veterans Affairs Tennessee Valley Healthcare System Tvhs Murfreesboro, Tennessee 37129, United States · NAICS 333120 Veterans Integrated Service Network 9 Service-Disabled Veteran-Owned Small Business Sole Source
Generator, aircraft, , in repair/modification of NAICS 333998 Naval Supply Systems Command No set-aside
Generator, alternati, in repair/modification of NAICS 335312 Naval Supply Systems Command No set-aside
Replace DSN-HDD Generator for 78th Signal Battalion, Camp Zama, Japan. Kanagawa Japan · NAICS 335312 Pacific Air Forces No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity