Demo_1_Off_Base_O&M_Manual_&_Drawings.pdf

PDF 34 MB Posted

Attached to
(IDIQ) for Remediation Services Contract for Joint Base Cape CodBourne, Massachusetts
Solicitation number
W912WJ18R0002
Issued by

About this file

Demo 1 Off Base O&M Manual & Drawings

View the file

Other files

File Type Posted
Amendment_0005.pdf PDF
Attachment_I-1_-_Prime_Binding_Rates_Rev_3-15-2018.xlsx XLSX spreadsheet
Attachment_I-2_-_Subcontractor_Binding_Rates_Rev_3-15-2018.xlsx XLSX spreadsheet
Amendment_0004.pdf PDF
Attachment_I-4_-_Seed_Task_Order_Rates_for_Subcontractor_Rev_3-15-2018.xlsx XLSX spreadsheet
Attachment_I-3_-_Seed_Task_Order_Rates_for_Prime_Rev_3-15-2018.xlsx XLSX spreadsheet
Demo_1_Decision_Document_2006.pdf PDF
J-3_Range_Decision_Document_2015_.pdf PDF
Demo_1_Decision_Document_Addendum_No._1_2009.pdf PDF
J-2_Range_Decision_Document_2013.pdf PDF
Demo_1_Decision_Document_Addendum_No.2_2013.pdf PDF
CIA_Decision_Document_2012.pdf PDF
IAGWSP_cameras_locations.pdf PDF
Amendment_0003.pdf PDF
J-1_Range_Decision_Document_2011.pdf PDF
Amendment_0002_.pdf PDF
Final_J-1_Range_South_RRA_SPM_Plan_2007.pdf PDF
J-3_Range_O&M_Manual_&_Drawings.pdf PDF
Attachment_I-4_-_Seed_Task_Order_Rates_for_Subcontractor_JM_Rev1.xlsx XLSX spreadsheet
Demo_1_Pew_Rd_&_Base_Boundary_O&M_Manual.pdf PDF
Attachment_I-1_-_Prime_Binding_Rates_Rev2.xlsx XLSX spreadsheet
CIA_1&2_O&M_Manual_&_Drawings.pdf PDF
Final_J-3_Range_RRA_SPEIM_Plan_2006.pdf PDF
Attachment_I-2_-_Subcontractor_Binding_Rates_Rev2.xlsx XLSX spreadsheet
Final_SPEIM_Plan_RRA_Systems_Demo_1_Groundwater_OU_2005.pdf PDF
QAPP_Appendix_D_Files.pdf PDF
Attachment_I-3_-_Seed_Task_Order_Rates_for_Prime_JMRev1.xlsx XLSX spreadsheet
SIR-110-Spec-Sheet.pdf PDF
J-1_North_O&M_Manual_&_Drawings_.pdf PDF
JBCC_GAC_Sample_Non-HazManifest-BOL.PDF PDF
PWS_JBCC_ID-IQ_Seed_Task_Order_3-5-2018_Rev.pdf PDF
Demo_1-Base_Boundary_GWT-_Drawings.pdf PDF
Final_J-2_Range_East_SPM_Plan_2008.pdf PDF
CIA_3_Leading_Edge_O&M_Manual_&_Drawings.pdf PDF
Final_J-2_North_RRA_PME_Plan.pdf PDF
Demo_1_Pew_Road_RRA_Plan_Nov2003.pdf PDF
Demo_1_Frank_Perkins_Road_O&M_Manual.pdf PDF
J-2_East_O&M_Manual.pdf PDF
Final_J-2_North_O&M_Manual_&_Drawings.pdf PDF
Final_J-1_SE_RRA_Eng_Specs_&_Drawings.pdf PDF
Demo_1_Leading_Edge_MTU.pdf PDF
CIA3_Range_MTU.pdf PDF
JBCC_camera_spec_sheet.pdf PDF
J2_Range_North_Treatment_Facility.pdf PDF
Amendment_0001.pdf PDF
Demo_1_Base_Boundary_MTU.pdf PDF
J2_Range_North_MTUs.pdf PDF
J1_Range_South_and_J2_Range_East.pdf PDF
J1_Range_North.pdf PDF
J3_Range.pdf PDF
Show 40 more

Latest 50 of 77 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Operations and Maintenance Manual

Joint Base Cape Cod – Demolition – Area 1

Impact Area Groundwater Study Program

Groundwater Treatment System – Off - Base

Camp Edwards, Massachusetts

Prepared by:

Prepared for:

Enclosures: Employee Contact Information Description of Water Treatment System Water Treatment System Figures Operations and Maintenance of Water Treatment System Equipment Cut Sheets Material Safety Data Sheets

Employee Contact Information

Employee Contact Information

If there are any questions or concerns regarding the system, please contact one of the following:

Phone List LRT Contact Cell

John Briggs 774-239-5714 Bryan Watkins 774-239-5783 Tony Zina 508-410-1440 Paul Lockwood 508-450-8802

Description of Water Treatment Systems

Description of Water Treatment System

This Mobile Treatment Unit (MTU) was constructed by Lockwood Remediation Technologies, LLC (LRT) on behalf of Tantara Corporation (Tantara) for the project referred to as Demolition Area 1 Groundwater Treatment System – located off base at The Massachusetts Military Reservation in Cape Cod, Massachusetts.

The mobile treatment unit (MTU) is capable of treating water at a flow rate of up to 125 gpm.

Groundwater is pumped to the MTU by one (1) 7.5 HP submersible pump (supplied by others) installed in extraction well No. 1 (supplied by others). The pump is controlled by a dedicated variable frequency drive (VFD) contained in Main Control Panel (MCP) located within the MTU. In the event of an alarm condition (i.e. low water pressure or flow from each well exceeding the specification error tolerance) the pump automatically shut down requiring manual restart.

From the pump, water enters a bag filter manifold with three (3) No. 2 single bag filters plumbed in parallel such that two bag filter vessel can be operated while the other remains on standby. During a bag filter change out, one vessel is removed from service while the other two remain in operation so that the MTU never needs to be shut down. Each bag filter housing is included with isolation valves, sample ports and pressure gauges on the influent and effluent piping so that it is clear when a bag filter change out is required. Bag filter housings are aluminum with each rated for maximum flow rate of 100 gpm and 125 PSI for cumulative flow rate of 300 gpm with two bag filter vessels online. From the bag filters, water is discharged to three vessels plumbed in series, the first containing 60 cubic feet (cuft) of ion exchange resin and the second and third containing 2,200 pounds of acid washed virgin liquid phase carbon. Each media vessel is rated for a maximum flow rate of 150 gpm and 75 PSI; for a total maximum cumulative flow rate of 150 gpm. From the MTU water is directed to a recharge gallery (installed by others).

The MTU is enclosed in steel container 40 feet long, 8 feet wide and 9.5 feet tall. This enclosure is fully heated, insulated and provided with lighting. There is also one courtesy outlet for 1-phase 110V within the treatment enclosure.

Water Treatment System Figures

P R

O

JE

C T

N o.

-1

Lockwood Remediation Technologies, LLC 89 Crawford Street Leominster, MA 01453 Office: 774-450-7177

DESIGNED BY: LRT DRAWN BY: B.Watkins

CHECKED BY: P. Lockwood DATE: Apri l 15, 2016

Demolition - Area 1 Groundwater Treatment System Site Plan

The Massachusetts Military Reservation Camp Edwards - Central Impact Area Cape Cod, Massachusetts

Tantara Corporation 54 Mason Street Worcester, Massachusetts 01610

F

IG

U R

E N o.

Source: Demolition – Area 1 – Off-Base Groundwater Treatment System Overall Site Plan Demo 1 Extraction Well by Tetra Tech dated June 12, 2015

O

JE

C T

N o.

-1

Lockwood Remediation Technologies, LLC 89 Crawford Street Leominster, MA 01453 Office: 774-450-7177

DESIGNED BY: LRT DRAWN BY: B.Watkins

CHECKED BY: P. Lockwood DATE: Apri l 15, 2016

Demolition – Area 1 Groundwater Treatment System Side View

The Massachusetts Military Reservation Camp Edwards - Central Impact Area Cape Cod, Massachusetts

Tantara Corporation 54 Mason Street Worcester, Massachusetts 01610

F

IG

U R

E

D ou bl e

D oo r

Man Door

Railing

Roof Hatches

Ladder

O

JE

C T

N o.

-1

Lockwood Remediation Technologies, LLC 89 Crawford Street Leominster, MA 01453 Office: 774-450-7177

DESIGNED BY: LRT DRAWN BY: B.Watkins

CHECKED BY: P. Lockwood DATE: Apri l 15, 2016

Demolition – Area 1 Groundwater Treatment System Schematic – 125 gpm

The Massachusetts Military Reservation Camp Edwards - Central Impact Area Cape Cod, Massachusetts

Tantara Corporation

54 Mason Street

Worcester, Massachusetts 01610

F

IG

U R

E

P

P

P

P

P

P

P P P

P P

Bag Filtration

Resin Vessel 1 Carbon Vessel 1 Carbon Vessel 2

Heaters

Overhead Lighting

Control Panel Man Door

Cargo Door

Influent

Discharge to

Recharge Gallery

Light

Switch &

Thermostat

Dehumidifier

Key

Check Valve

Sample Port/Air Release Valve

Ball Valve

Flow Meter

Pressure Gauge

Siphon Break

Operations and Maintenance of Water Treatment Systems

Water Treatment System Start Up Check List

Before Starting System:

• Check bag filters and change if needed.

• Open shutoff valves on influent and effluent side of bag filters.

• Open shutoff valves on the Resin and Carbon vessels.

• Open valve on the discharge line leading to the recharge gallery.

• Close all sample ports and bleeder valves.

• Pull out all emergency stop buttons.

To activate the MTU:

• Turn on control power to MCP.

• On the system screen touch menu button and go to the overview screen.

• On the overview screen turn the well pump to auto mode.

• Verify set point for pump flow rate.

• To change flow rate, touch target button on PID screen to pull up set point screen. Then enter the desired flow rate and touch the enter button.

• The Pump will start at a preset minimum of 30 Hz then gradually increase until reaching the set point pump.

After System is Operating:

• Open bleeder valve on the top of each bag filter housing until all air is removed.

• Open bleeder valve on the top of each resin vessel until all air is removed.

• Open bleeder valve on the top of each carbon vessel until all air is removed.

• Check system pressure. Ideal operating pressure is less than 35 PSI. IF OPERATING

PRESSURES EXCEED 60 PSI, SHUT SYSTEM DOWN UNTIL OPERATING

PRESSURE IS REDUCED.

• Pump flow should stabilize to set point within 10 minutes.

• Bag filters should be changed when the pressure differential exceeds 5 PSI.

• Media vessels should be backwashed if the pressure differential exceeds 5 PSI.

Main Control Panel Operations

The main control system is accessed via a touch screen on the panel. In order to change any set point on the system through the touch screen, the password below must be entered.

Password: 12345

Once the main control system is accessed, the following screens will be used to interact with the extraction well system.

Screen #1 – Main Menu

The main menu contain five (5) possible options which allow the operator to access live data as well as change various system variables.

Screen #2 – System Overview

The system overview screen allows the operator to place the well pump in “hand” or “auto” as well as set multiple set points for the system. “Hand” mode runs the pump manually. “Auto” mode runs the pump with the specified flow in place. All system set points can be manually altered to maintain ideal system operating conditions.

Screen #3 – Alarms

The Alarms screen logs alarm history detailing the alarm type as well as the time activated/deactivated.

This allows the operator to view a system alarm history.

Screen #4 – Flow, Pressure and Differential Trend

The flow/pressure/differential trend screen allows the operator to view historic system data (flow/pressure/differential) over time in the form of a line graph.

Water Treatment System Shutdown Procedures

To turn off system from the MCP, go to the system overview screen and touch the off button.

In an emergency situation the system can be shut down by pushing the emergency stop buttons located on the control panel.

Operations and Maintenance of Water Treatment System

Submersible Pump:

The operator will need to check the submersible pump to ensure smooth operation. The pump should be running continuously as long as it is energized. If flow becomes slow and turbulent, the operator should check the pumps for sediment buildup in the bottom screens.

Bag Filters:

Three (3) No 2 filter housings will be plumbed in parallel such that two bag filter vessels can be operated while one remains on standby. Each bag filter vessel is rated to 100 gpm (400 gpm total) and 125 PSI and include isolation valves, sample ports and pressure gauges on the influent and effluent piping so that it is clear when a bag filter change out is required. When there is a differential pressure of no more than 5 PSI, the operator will need to complete a bag filter change out. During a bag filter change out, two vessels are opened while one is closed so that water treatment never needs to be shut down. The bag filters are a one-time use only and should be properly disposed of after use.

Resin Vessels:

One (1) resin vessel will contain 60 cuft of Resin Tech SIR-100-HP ion exchange resin. The vessel is rated for 150 gpm and 75 PSI and includes isolations valves, sample ports and pressure gauges on the influent and effluent piping so that it is clear when backwashing is required. When there is a pressure differential of 5 PSI, backwashing should occur. Backwashing is completed by reversing the flow direction at a rate of 200 gpm for 0.5 hours per vessel or when the backwash water is clear. The operator must use a clean water source for backwashing (i.e. a fire hydrant). A resin change out is necessary when breakthrough begins to occur at the effluent sampling port of the resin vessel.

Carbon Vessels:

Two (2) carbon vessels will contain 2,200 pounds of reactivated liquid phase reactivated carbon. The vessels are rated for 150 gpm and 75 PSI (and include isolation valves, sample ports and pressure gauges on the influent and effluent piping so that it is clear when backwashing is required. When there is a pressure differential of 5 PSI, backwashing should occur. Backwashing is completed by reversing the flow direction at a rate of 200 gpm for 0.5 hours per vessel or when the backwash water is clear. The operator must use a clean water source for backwashing (i.e. a fire hydrant). A carbon change out is necessary when breakthrough begins to occur at the effluent sampling port of the carbon vessel.

Equipment Cut Sheets

Controls

DANGER!

UPS VOLTAGE PRESENT

WHEN POWER IS OFF.

Contact may cause Electrical Shock or Burn.

Turn off UPS Output Power Before Servicing.

! WARNING

G �G �

SURGE TRAP® DIN RAIL TVSS

DIN RAIL TVSS (ThERmALLy PRoTEcTED)

The Surge Trap® TVSS from Ferraz Shawmut is an innovative enhancement to the existing TPMOV® (Thermally Protected MOV) Product line. The Surge-Trap provides a patented, thermally protect-ed MOV that does not require additional overcurrent protection, due to the high interrupting rating.

It also offers the flexibility to be connected indi-vidually or ganged together. Each individual mode has a visual and remote indicator to provide status to critical control circuits.

APPLIcATIoN:

Transient Voltage Surge Suppressors AC/DC Distribution High Voltage Power Supplies Telecom Motor Control Systems PLC Applications Power Transfer Equipment

MCOV 150 to 550

50kA 8/20us Capacity per mode

Ratings Approvals

Features/Benefits High Energy Capacity

Din-Rail Mountable (35mm)

IP20 - Fingersafe

Built in Visual/Remote Indication

Built in Thermal Protection

100kA Interrupting Rating

➤Dimensions

SURGE SUPPRESSIoN

UL 1449 file E210793 Second Edition 2005 Component Recognition

RoHs Compliant

Gross Automation (877) 268-3700 · www.ferrazshawmutsales.com · sales@grossautomation.com

G

G �

G

G �

SURGE TRAP® DIN RAIL TVSS SURGE SUPPRESSION

Surge Trap Selection guide:

STEP 1: Select electrical voltage configuration from first column STEP 2: Select proper modes of protection from third column STEP 3: Select corresponding catalog number from fourth column STEP 4: Add an M to the catalog number if you require remote indication

Single Phase 2 Wire + Ground

Split Phase 3 Wire + Ground

3 Phase Wye 4 Wire + Ground

3 Phase Delta 3 Wire + Ground

A B C D E

Gross Automation (877) 268-3700 · www.ferrazshawmutsales.com · sales@grossautomation.com glangley Rectangle

2880 North Plaza Drive • Rapid City, SD 57702

(800) 843-8848 • (605) 348-5580 • FAX (605) 348-5685

www.symcominc.com • email: sales@symcominc.com

Features

Model

460-XXX-SP

Single-Phase

Voltage Monitor

Engineered Protection

Microcontroller

Based

Universal range from 95-120 or 190-240VAC, 50/60 Hz provides the versatility needed to handle global applications.

Two adjustment pots provide versatility for all kinds of applications.

Diagnostic LEDs indicate trip status and provide simple troubleshooting.

Microcontroller-based circuitry provides better accuracy and higher reliability than analog designs.

Transient protection meets IEEE and IEC standards to allow operation under tough conditions.

The Model 460-XXX-SP protects single-phase motors from damage caused by low and high voltage and rapid cycling. Controls are provided to set the nominal voltage (190-240VAC) and the desired restart delay time (1-500 sec.).

A unique microcontroller-based, voltage-sensing circuit constantly monitors the voltage to detect harmful power line conditions. When a harmful condition is detected, the MotorSaver's output relay is deactivated after a specified trip delay. The output relay reactivates after power line conditions return to an acceptable level for a specified amount of time (restart delay). The restart delay is also a power-up delay and can be utilized to stagger-start motors on the same system. The trip delay prevents nuisance tripping due to rapidly fluctuating power line conditions.

Protects Single-Phase Motors From:

• Low voltage

• High voltage

• Rapid cycling

Additional Features:

• Compact design

• Standard 1-500 sec.

variable restart delay

• Standard surface or

DIN rail mountable

• Finger-safe terminals

• One 10 Amp general purpose Form C relay

• Optional manual reset

• UL and cUL listed

• CE compliant

• 5-year warranty

• Made in USA

VOLTAGE ADJ. (VAC) RESTART (SEC)

MODEL

460-XXX-SP

230 20 250

LED STATUSRUN

RESTART DELAY

HIGH / LOW VOLTAGE

GREEN

GREEN

RED

4 5 6

10/05

2880 North Plaza Drive • Rapid City, SD 57702

(800) 843-8848 • (605) 348-5580 • FAX (605) 348-5685

www.symcominc.com • email: sales@symcominc.com

SymCom warrants its microcontroller based products against defects in material or workmanship for a period of five (5) years from the date of manufacture. All other products manufactured by SymCom shall be warranted against defects in material and workmanship for a period of two (2) years from the date of manufacture.

For complete information on warranty, liability, terms, returns, and cancellations, please refer to the SymCom Terms and Conditions of Sale document.

Specifications

Operating Points

Special Options

Specifications Single-Phase Line Voltage

460-100-SP ............................................95-120VAC

460-200-SP ............................................190-240VAC

Frequency ..............................................50*/60 Hz Low Voltage (% of setpoint) •Trip ........................................................90% ±1% •Reset......................................................93% ±1% High Voltage (% of setpoint) •Trip ........................................................110% ±1% •Reset......................................................107% ±1% Trip Delay Time •Low or High Voltage ..............................4 seconds Restart Delay Time •After a Fault ..........................................1-500 seconds adjustable •After a Complete Power Loss ................1-500 seconds adjustable Output Contact Rating •1-Form C................................................10 A General Purpose @ 240VAC ................................................................Pilot Duty 480VA @ 240VAC, B300 Power Consumption ............................6 Watts (max.)

Weight ..................................................14 oz.

Enclosure ..............................................Polycarbonate Terminal Torque ....................................6 in.-lbs.

Wire Type................................................Stranded or solid 12-20 AWG, one per terminal Safety Marks

•UL ..........................................................UL508

•CE ..........................................................IEC 60947-6-2

Standards Passed •Electrostatic Discharge (ESD) ..............IEC 1000-4-2, Level 3, 6kV contact, 8kV air •Radio Frequency Immunity, Radiated....150 MHz, 10V/m •Fast Transient Burst ..............................IEC 1000-4-4, Level 3, 3.5 kV input power & controls Surge •IEC ........................................................IEC 1000-4-5, Level 3, 4kV line-to-line;

................................................................Level 4, 4kV line-to-ground •ANSI/IEEE ............................................C62.41 Surge and Ring Wave Compliance ................................................................to a level of 6kV line-to-line •Hi-potential Test ....................................Meets UL508 (2 x rated V +1000V for 1 minute)

Environmental Temperature Range ................................Ambient Operating: -20° to 70° C (-4° to 158°F) ................................................................Ambient Storage: -40° to 80° C (-40° to 176°F) Class of Protection..................................IP20, NEMA 1 (finger safe) Relative Humidity ....................................10-95%, non-condensing per IEC 68-2-3 Special Options Manual Reset ..........................................External momentary pushbutton required.

*Note: 50 Hz will increase all delay timers by 20%

10/05

VOLTAGE ADJ. (VAC) RESTART (SEC)

MODEL 460-SP

230 20 250

LED STATUSRUN

RESTART DELAY

HIGH / LOW VOLTAGE

GREEN

GREEN

RED

Model 460-XXX-SP Single-Phase

Voltage Monitor

FRONT VIEW

BOTTOM VIEW

SIDE VIEW

TYPICAL WIRING DIAGRAM

https://www.phoenixcontact.com/us/products/2902994

12/04/2015 Page 1 / 6

Power supply unit - UNO-PS/1AC/24DC/90W/C2LPS - 2902994 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download)

Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/90 W

Product Description UNO POWER power supplies with basic functionality Thanks to their high power density, compact UNO POWER power supplies are the ideal solution for loads up to 100 W, particularly in compact control boxes. The power supply units are available in various performance classes and overall widths. Their high degree of efficiency and low idling losses ensure a high level of energy efficiency.

Product Features

Flexible mounting by simply snapping onto the DIN rail

More space in the control cabinet with up to 20 % higher power density

Maximum energy efficiency, thanks to over 90 % efficiency and extremely low idling losses under 0.3 W

Key Commercial Data Packing unit 1 pc

Weight per Piece (excluding packing) 400.0 g

Custom tariff number 85044030

Country of origin Germany

Technical data

Dimensions Width 55 mm

Height 90 mm

Depth 84 mm

Ambient conditions Degree of protection IP20

Ambient temperature (operation) -25 °C ... 70 °C (> 55° C derating : 2.5%/K)

12/04/2015 Page 2 / 6

Power supply unit - UNO-PS/1AC/24DC/90W/C2LPS - 2902994 Technical data

Ambient conditions Ambient temperature (storage/transport) -40 °C ... 85 °C

Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)

Noise immunity EN 61000-6-2:2005

Input data Nominal input voltage range 100 V AC ... 240 V AC

Input voltage range 85 V AC ... 264 V AC

AC frequency range 45 Hz ... 65 Hz

Inrush surge current < 40 A (typical)

Power failure bypass > 25 ms (120 V AC)

> 100 ms (230 V AC)

Input fuse 3.15 A (slow-blow, internal)

Choice of suitable circuit breakers 6 A ... 16 A (Characteristics B, C, D, K)

Type of protection Transient surge protection

Protective circuit/component Varistor

Output data Nominal output voltage 24 V DC ±1 %

Nominal output current 3.75 A Uin = 85 V AC ... 264 V AC (-25°C ... 55°C)

Derating 55 °C ... 70 °C (2.5%/K)

Connection in parallel No

Connection in series No

Control deviation < 1 % (change in load, static 10 % ... 90 %)

< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)

< 0.1 % (change in input voltage ±10 %)

Residual ripple < 45 mVPP (with nominal values)

Output power 90 W

Typical response time < 1 s

Maximum power dissipation in no-load condition < 0.5 W

Power loss nominal load max. < 12 W

General Net weight 0.34 kg

Efficiency > 88.5 % (for 230 V AC and nominal values)

Insulation voltage input/output 4 kV AC (type test)

3 kV AC (routine test)

Protection class II (in closed control cabinet)

MTBF (IEC 61709, SN 29500) > 1159000 h (40°C)

Mounting position horizontal DIN rail NS 35, EN 60715

12/04/2015 Page 3 / 6

Power supply unit - UNO-PS/1AC/24DC/90W/C2LPS - 2902994 Technical data

General Assembly instructions Alignable: 0 mm horizontally, 30 mm vertically

Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC

Low Voltage Directive Conformance with LV directive 2006/95/EC

Standard – Electrical equipment of machines EN 60204-1

Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)

Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)

Standard - Safe isolation DIN VDE 0100-410

Standard – Limitation of mains harmonic currents EN 61000-3-2

Approval - requirement of the semiconductor industry with regard to mains voltage dips EN 61000-4-11

Information technology equipment - safety (CB scheme) CB Scheme

UL approvals UL/C-UL listed UL 508

UL/C-UL Recognized UL 60950

NEC Class 2 as per UL 1310

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)

Connection data, input Connection method Screw connection

Conductor cross section solid min. 0.2 mm²

Conductor cross section solid max. 2.5 mm²

Conductor cross section flexible min. 0.2 mm²

Conductor cross section flexible max. 2.5 mm²

Conductor cross section AWG min. 24

Conductor cross section AWG max. 14

Stripping length 8 mm

Screw thread M3

Connection data, output Connection method Screw connection

Conductor cross section solid min. 0.2 mm²

Conductor cross section solid max. 2.5 mm²

Conductor cross section flexible min. 0.2 mm²

Conductor cross section flexible max. 2.5 mm²

Conductor cross section AWG min. 24

Conductor cross section AWG max. 14

Stripping length 8 mm

12/04/2015 Page 4 / 6

Power supply unit - UNO-PS/1AC/24DC/90W/C2LPS - 2902994 Technical data

Connection data, output Screw thread M3

Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC

Shock 30g in each direction, according to IEC 60068-2-27

Noise immunity EN 61000-6-2:2005

Connection in acc. with standard CUL

Standards/regulations EN 61000-4-3

EN 61000-4-4

EN 61000-4-6

Standard – Electrical equipment of machines EN 60204-1

Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)

Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)

Standard - Safe isolation DIN VDE 0100-410

Standard – Limitation of mains harmonic currents EN 61000-3-2

UL approvals UL/C-UL listed UL 508

UL/C-UL Recognized UL 60950

NEC Class 2 as per UL 1310

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)

Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)

Low Voltage Directive Conformance with LV directive 2006/95/EC

Approval - requirement of the semiconductor industry with regard to mains voltage dips EN 61000-4-11

Information technology equipment - safety (CB scheme) CB Scheme

Classifications eCl@ss eCl@ss 4.0 27040702 eCl@ss 4.1 27040702 eCl@ss 5.0 27049002 eCl@ss 5.1 27049002 eCl@ss 6.0 27049002 eCl@ss 7.0 27049002 eCl@ss 8.0 27049002 eCl@ss 9.0 27040701

12/04/2015 Page 5 / 6

Power supply unit - UNO-PS/1AC/24DC/90W/C2LPS - 2902994 Classifications

ETIM

ETIM 3.0 EC001039

ETIM 4.0 EC002540

ETIM 5.0 EC002540

UNSPSC

UNSPSC 6.01 30211502

UNSPSC 7.0901 39121004

UNSPSC 11 39121004

UNSPSC 12.01 39121004

UNSPSC 13.2 39121004

Approvals

Approvals

Approvals

UL Recognized / UL Listed / cUL Recognized / cUL Listed / IECEE CB Scheme / cULus Recognized / cULus Listed

Ex Approvals

UL Listed / cUL Listed / cULus Listed

Approvals submitted

Approval details

UL Recognized

UL Listed cUL Recognized

12/04/2015 Page 6 / 6

Power supply unit - UNO-PS/1AC/24DC/90W/C2LPS - 2902994 Approvals cUL Listed

IECEE CB Scheme cULus Recognized cULus Listed

Drawings

Block diagram

N

L +

Phoenix Contact 2015 © - all rights reserved http://www.phoenixcontact.com

Getting started Installing the software and configuring the C-more panel is simple. You will need the following to successfully connect, configure and send a project to the panel:

• C-more touch panel - 6”, 8”, 10”, 12” or 15” model

• C-more Programming Software, p/n EA9-PGMSW

• C-more programming cable, USB or Ethernet

• 12-24 VDC switching power supply or the optional C-more AC Power Adapter, p/n EA-AC

• Personal Computer - to run C-more programming software

• PLC communications cable (serial or Ethernet) to connect the C-more Touch Panel to your controller

C-more Operator Panels Overview

Part Number Description Price

EA9-T6CL-R

C-more EA9 series touch screen interface panel, 6-inch color TFT (5.7 inch viewable screen), base model, 64k colors, 320 x 240 pixel QVGA screen resolution, 800 MHz CPU, 12-24 VDC powered, NEMA 4/4X, IP65 (when mounted correctly; for indoor use only), non-replaceable LED backlight. Includes (1) serial port, USB 2.0 Type A and B ports, supports SD memory card, no Ethernet support.

Compatible with EA9-PGMSW programming software version 5.0 or later.

$499.00

EA9-T6CL

C-more EA9 series touch screen interface panel, 6-inch color TFT (5.7 inch viewable screen), 64k colors, 320 x 240 pixel QVGA screen resolution, 800 MHz CPU, 12-24 VDC powered, NEMA 4/4X, IP65 (when mounted correctly; for indoor use only), non-replaceable LED backlight. Includes (3) serial ports, USB 2.0 Type A and B ports and Ethernet port; supports SD memory card. Compatible with EA9-PGMSW programming software version 5.0 or later.

$699.00

EA9-T8CL

C-more EA9 series touch screen interface panel, 8-inch color TFT (8.4 inch viewable screen), 64k colors, 800 x 600 pixel SVGA screen resolution, 800 MHz CPU, 12-24 VDC powered, NEMA 4/4X, IP65 (when mounted correctly; for indoor use only), non-replaceable LED backlight. Includes (3) serial ports, USB 2.0 Type A and B ports and Ethernet port; supports SD memory card. Compatible with EA9-PGMSW programming software version 5.0 or later.

$999.00

EA9-T10CL

C-more EA9 series touch screen interface panel, 10-inch color TFT (10.4 inch viewable screen), 64k colors, 800 x 600 pixel SVGA screen resolution, 800 MHz CPU, 12-24 VDC powered, NEMA 4/4X, IP65 (when mounted correctly; for indoor use only), non-replaceable LED backlight. Includes (3) serial ports, USB 2.0 Type A and B ports and Ethernet port; supports SD memory card. Compatible with EA9-PGMSW programming software version 5.0 or later.

$1,290.00

EA9-T12CL

C-more EA9 series touch screen interface panel, 12-inch color TFT (12.1 inch viewable screen), 64k colors, 800 x 600 pixel SVGA screen resolution, 800 MHz CPU, 12-24 VDC powered, NEMA 4/4X, IP65 (when mounted correctly; for indoor use only), non-replaceable LED backlight. Includes (3) serial ports, USB 2.0 Type A and B ports and Ethernet port; supports (2) SD memory cards. Includes HDMI video out. Compatible with EA9-PGMSW programming software version 5.0 or later.

$1,790.00

EA9-T15CL

C-more EA9 series touch screen interface panel, 15-inch color TFT (15 inch viewable screen), 64k colors, 1024 x 768 pixel XGA screen resolution, 800 MHz CPU, 12-24 VDC powered, NEMA 4/4X, IP65 (when mounted correctly; for indoor use only), non-replaceable LED backlight. Includes (3) serial ports, USB CR-272.0 Type A and B ports and Ethernet port; supports (2) SD memory cards. Includes HDMI video out. Compatible with EA9-PGMSW programming software version 5.0 or later.

$1,999.00

EA9-PGMSW

C-more Windows-based programming software on CD for the C-more EA9 series touch panels. Requires Windows XP Pro 32-bit, Windows 7 (Pro, Ultimate, 32 or 64-bit) or Windows 8 (Pro, Ultimate, 32 or 64-bit). Requires USB or Ethernet connection to touch panel.

Cables sold separately. (Does not support C-more EA7 series panels.)

$99.00

USB-CBL-AB3

Standard 3-ft. (0.9m) USB 2.0 cable, A-type connector to B-type connector, used to connect personal computer to any C-more touch panel for setup and programming. (Note: Touch panels require a power source for configuration and operation.)

$7.50

USB-CBL-AB6

Standard 6-ft. (1.8m) USB 2.0 cable, A-type connector to B-type connector, used to connect personal computer to any C-more touch panel for setup and programming. (Note: Touch panels require a power source for configuration and operation.)

$9.50

USB-CBL-AB10

Standard 10-ft (3 meter) USB 2.0 cable, A-type connector to B-type connector, used to connect personal computer to any C-more touch panel for setup and programming. (Note: Touch panels require a power source for configuration and operation.)

$18.00

USB-CBL-AB15

Standard 15-ft. (4.6m) USB 2.0 cable, A-type connector to B-type connector, used to connect personal computer to any C-more touch panel for setup and programming. (Note: Touch panels require a power source for configuration and operation.)

$22.50 w w w . a u t o m a t i o n d i r e c t . c o m / C - m o r e eCR-27 Book 1 (14.3)

Prices as of April 15, 2015. Check Web site for most current prices.

C-more Operator Touch Panels

Company Information

Control Systems Overview

CLICK PLC

Do-More PLCs Overview

Do-More H2

PLC

Do-More T1H

PLC

DirectLOGIC PLCs Overview

DirectLOGIC

DL05/06

DirectLOGIC

DL105

DirectLOGIC

DL205

DirectLOGIC

DL305

DirectLOGIC

DL405

Productivity Controller Overview

Productivity

Universal Field I/O

Software

C-More

HMI

C-More Micro

HMI

ViewMarq Industrial Marquees

Other HMI

Communications

Appendix Book 1

Terms and Conditions http://www.automationdirect.com/pn/USB-CBL-AB10 http://www.automationdirect.com/pn/USB-CBL-AB15 http://www.automationdirect.com/pn/USB-CBL-AB3 http://www.automationdirect.com/pn/USB-CBL-AB6 http://www.automationdirect.com/pn/EA9-T6CL-R http://www.automationdirect.com/pn/EA9-PGMSW http://www.automationdirect.com/pn/EA9-PGMSW http://www.automationdirect.com/pn/EA9-PGMSW http://www.automationdirect.com/pn/EA9-PGMSW http://www.automationdirect.com/pn/EA9-T10CL http://www.automationdirect.com/pn/EA9-PGMSW http://www.automationdirect.com/pn/EA9-T12CL http://www.automationdirect.com/pn/EA9-PGMSW http://www.automationdirect.com/pn/EA9-T15CL http://www.automationdirect.com/pn/EA9-PGMSW http://www.automationdirect.com/pn/EA9-PGMSW http://www.automationdirect.com/pn/EA9-T6CL http://www.automationdirect.com/pn/EA9-T8CL http://www.automationdirect.com/pn/EA-AC

Model 6” TFT color w/ base features

6” TFT color w/ full features

8” TFT color w/ full features

10” TFT color w/ full features

12” TFT color w/ full features

15” TFT color w/ full featuresSpecification

Part Number EA9-T6CL-R EA9-T6CL EA9-T8CL EA9-T10CL EA9-T12CL EA9-T15CL

Price $499.00 $699.00 $999.00 $1,290.00 $1,790.00 $1,999.00

Display Actual Size and Type 5.7” TFT color 8.4” TFT color 10.4” TFT color 12.1” TFT color 15.0” TFT color

Display Viewing Area 4.54” x 3.40” [115.2 mm x 86.4 mm]

6.71” x 5.03” [170.4 mm x127.8mm]

8.31” x 6.24” [211.2 mm x 158.4 mm]

9.69” x 7.26” [246.0 mm x 184.5 mm]

11.97” x 8.98” [304.1 mm x 228.0 mm]

Weight 1.56 lb [710g] 1.59 lb [720g] 2.93 lb [1330g] 4.19 lb [1900g] 4.89 lb [2200g] 6.50 lb [2950g]

Screen Pixels 320 x 240 (QVGA) 800 x 600 (SVGA) 1024 x 768 (XGA)

Display Brightness 280 nits (typ) 310 nits (typ) 280 nits (typ)

LCD Panel Dot Pitch 0.18 mm x 0.18 mm 0.213 mm x 0.213 mm 0.264 mm x 0.264 mm 0.3075 mm x 0.3075 mm 0.297 mm x 0.297 mm

Color Scale 65,536 colors

Backlight Average Lifetime* 50,000 hours @ 25°C

Touch Panel Type** Four-wire analog resistive, single touch

Project Memory 26MB 82MB

Number of Screens Up to 999 screens – limited by project memory

Realtime Clock Realtime Clock Built into panel, backed up for 30 days at 25°C

Calendar - Month / Day / Year Yes - monthly deviation 60 sec (Reference)

Serial Port 1 15-pin D-sub female - RS232C, RS-422/485

Serial Port 2 N/A 3-wire terminal block - RS-485

Serial Port 3 N/A RJ-12 modular jack - RS-232C

USB Port - Type B USB 2.0 High speed (480 Mbps) Type B - Download/Program

USB Port - Type A USB 2.0 High speed (480 Mbps) Type A -for USB device options

Ethernet Port N/A Ethernet Port Ethernet 10/100 Base-T, auto MDI/MDI-X

Audio Line Out N/A 3.5 mm mini jack – requires amplifier and speaker(s)

Mic In (Future) N/A 3.5 mm mini jack

SD Card Slot 1 slot supports max 2 GB (SD,) max 32 GB (SDHC) 2 slots support max 2 GB (SD), max 32 GB (SDHC)

HDMI Video Out N/A Yes

HDMI Supported Resolution N/A 800 x 600 (SVGA) 1024 x 768 (XGA)

Supply Power 10.2-26.4 VDC Class 2, or use the AC/DC Power Adapter, EA-AC, to power the touch panel from a 100-240 VAC, 50/60 Hz power source.

Reverse Polarity Protected

Power Consumption

16.0 W

1.30 A @ 12VDC

0.66 A @ 24VDC

18.0 W

1.50 A @ 12VDC

0.75 A @ 24VDC

18.0 W

1.50 A @ 12VDC

0.75 A @ 24VDC

21.0 W

1.75 A @ 12VDC

0.88 A @ 24VDC

29.0 W

2.40 A @ 12VDC

1.20 A @ 24VDC

Internal Fuse (non-replaceable) 4.0 A 6.3 A

Operating Temperature 0 to 50 °C (32 to 122 °F) Maximum surrounding air temperature rating: 50°C (122°F) IEC 60068-2-14 (Test Nb, Thermal Shock)

Storage Temperature –20 to +60°C (–4 to +140 °F) IEC 60068-2-1 (Test Ab, Cold) IEC 60068-2-2 (Test Bb, Dry Heat) IEC 60068-2-14 (Test Na, Thermal Shock)

Humidity 5–95% RH (non-condensing)

Environment For use in Pollution Degree 2 environment, no corrosive gases permitted

Noise Immunity NEMA ICS3-304 ( EN61131-2 ) RFI, (145MHz, 440Mhz 10W @ 10cm)

Impulse 1000V @ 1mS pulse EN61000-4-2 (ESD), EN61000-4-3 (RFI) EN61000-4-4 (FTB) EN61000-4-5 (Serge) EN61000-4-6 (Conducted)

EN61000-4-8 (Power frequency magnetic field immunity) Withstand Voltage 1000 VAC, 1 min. (FG to Power supply )

Insulation Resistance > 10M ohm @ 500VDC (FG to Power supply )

Vibration IEC60068-2-6 (Test Fc)

Shock IEC60068-2-27 (Test Ea)

Emission EN55011 Class A (Radiated RF emission)

Enclosure NEMA 250 type 4/4X indoor use only UL50 type 4X indoor use only IP-65 indoor use only (When mounted correctly)

Agency Approvals

UL508, E157382

CE (EN61131-2), RoHS (2011/65/EU) CUL Canadian C22.2

NOTES: *The backlight average lifetime is defined as the average usage time it takes before the brightness becomes 50% of the initial brightness. The lifetime of the backlight depends on the ambient temperature. The lifetime will decrease under low or high temperature usage.

**The touchscreen is designed to respond to a single touch. If it is touched at multiple points at the same time, an unexpected object may be activated.

C-more Selection Guide & Specifications

1 - 8 0 0 - 6 3 3 - 0 4 0 5eCR-28 Book 1 (14.3)

Prices as of April 15, 2015. Check Web site for most current prices.

C-more Operator Touch Panels http://www.automationdirect.com/pn/EA9-T6CL-R http://www.automationdirect.com/pn/EA9-T10CL http://www.automationdirect.com/pn/EA9-T12CL http://www.automationdirect.com/pn/EA9-T15CL http://www.automationdirect.com/pn/EA9-T6CL http://www.automationdirect.com/pn/EA9-T8CL http://www.automationdirect.com/pn/EA-AC

C-more 8” TFT Color Touch Panel - Full Model

C-more EA9 series touch screen interface panel, 8-inch color TFT (8.4 inch viewable screen), 64k colors, 800 x 600 pixel SVGA screen resolution, 800 MHz CPU, 12-24 VDC powered, NEMA 4/4X, IP65 (when mounted correctly; for indoor use only), non-replaceable LED backlight. Includes (3) serial ports, USB 2.0 Type A and B ports and Ethernet port; supports SD memory card. Compatible with EA9-PGMSW programming software version 5.0 or later.

Part No. EA9-T8CL

Features

• 8.4” diagonal color TFT (Thin Film

Transistor) LCD display with 64K colors

• 800 x 600 pixel resolution

• 310 NITS display brightness

• 50,000 hour average backlight half-life

• Analog resistive (1024 X 1024) touch screen allowing unlimited touch areas

• USB port B (program/download) and USB port A (USB device options)

• Ethernet 10/100 Base-T port (program/download & PLC communication)

• Remote Internet Access

• Serial PLC interface (RS-232/422/485)

• One built-in SD memory card slot

• 12–24 VDC powered, 110VAC power adapter (optional)

• Audio Line Out, stereo - requires amplifier and speaker(s)

• 26MB project memory

• Data logging

• 0 to 50°C [32 to 122°F] operating temperature range

• NEMA 4/4X, IP65 compliant when mounted correctly, indoor use only

• Slim design saves panel space

• UL, cUL & CE agency approvals

• 2-year warranty from date of purchase

$999.00

Function Available Ethernet Yes

USB Yes SD Card Yes

Audio Out Yes HDMI Video Out No

ULC USR

Mounting Cutout inches / [mm] Dimensions w w w . a u t o m a t i o n d i r e c t . c o m / C - m o r e eCR-31 Book 1 (14.3)

Prices as of April 15, 2015. Check Web site for most current prices.

C-more Operator Touch Panels

Company Information

Control Systems Overview

CLICK PLC

Do-More PLCs Overview

Do-More H2

PLC

Do-More T1H

PLC

DirectLOGIC PLCs Overview

DirectLOGIC

DL05/06

DirectLOGIC

DL105

DirectLOGIC

DL205

DirectLOGIC

DL305

DirectLOGIC

DL405

Productivity Controller Overview

Productivity

Universal Field I/O

Software

C-More

HMI

C-More Micro

HMI

ViewMarq Industrial Marquees

Other HMI

Communications

Appendix Book 1

Terms and Conditions http://www.automationdirect.com/pn/EA9-PGMSW http://www.automationdirect.com/pn/EA9-T8CL

USB Port - Type B Programming

2 1

3 4

Pin Signal

1 N.C.

D–

D+

GND

ShieldShell

USB Port - Type A USB Device Options

Pin Signal

1 Vbus

D–

D+

GND

ShieldSHELL

Ethernet 10/100 Base-T PLC Communications, Programming/Download

1 8

Pin Signal

1 TD+

TD–

RD+

do not use

Pin Signal

5 do not use

RD–

N.C.

N.C.

Network Speed LED (Yellow)

On 100M

10MOff

SD Card Slot 1

SD Card Slot 2

HDMI Port Video Out

Note: Device is not available on Base Feature touch panel EA9-T6CL-R

8 1

15 9

Port 1 PLC Serial Communications

RS-232C / RS-485

Pin Signal

1 Frame GND

TXD (232C)

RXD (232C)

VCC

(Supplies +5VDC)

5 Logic GND

Pin Signal Pin Signal

6 LE (for DH485)

CTS (232C)

RTS (232C)

RXD+ (422/485)

10 RXD– (422/485)

11 TXD+ (422/485)

TXD– (422/485)

Term. Resistor

N.C.

15 N.C.

1 6

Pin Signal

1 0V

N.C.

RXD

TXD

Supplies +5VDC5

0V6

Port 3 RJ12 Serial Communication

RS-232C

Logic Ground

Port 2 Serial Communication

RS-485

Note: Device is only available on touch panels EA9-T12CL and EA9-T15CL.

Link Status LED (Green)

On Ethernet Linked

No Ethernet Comm.Off

Comm. ActivityBlinking Green

C-more Communication Ports

Ethernet Port The Ethernet port has several uses:

• Download program to panel

• Communicate to PLCs/PCs

• Send e-mail

• Access FTP server

• Act as a Web server

• Remote Internet Access

The Ethernet port has an RJ-45 8-wire modular connector with green and yellow LEDs.

• The yellow LED indicates network speed;

off for a 10 Mbps connection and illuminated for a 100 Mbps connection.

• The green LED indicates link status and illuminates when a link is established.

Note: The base panels (-R part numbers) do not include an Ethernet port, and do not have these capabilities.

Sound Interface (Audio Line Out) When attached to an amplifier and speaker(s), C-more can play warning sounds or pre-recorded messages such as: “conveyor is jammed”. C-more supports WAV type files. The output is stereo.

Serial Port Port 1 - Connect to your serial controller network via Port 1. Port 1 is a 15-pin port that supports RS-232 or RS-422/485.

Port 2 - Connect your RS-485 network via Port 2. Port 2 is provided with a 3-wire removable terminal block.

Port 3 - Connect to your RS-232C device via Port 3. Port 3 is an RJ12 connection.

HDMI Video Out EA9-T12CL and EA9-T15CL include an HDMI Type A port to provide video output to a projector or remote monitor.

USB Port B Program C-more via the USB program-ming port. It’s fast and easy, with no baud rate settings, parity, or stop bits to worry about. We stock standard USB cables for your convenience. USB Port B can be used to upload or download projects to and from a PC.

USB Port A The Universal Serial Bus (USB) Port A is a standard feature for all models and can be used to connect various USB HID (Human Input Device) devices to the panel, such as:

• USB pen drives, (USB-FLASH)

• USB keyboards

• USB barcode scanners

• USB card scanners

C-more can log data to the USB pen drive as well as load projects to the panel from the pen drive. You can also back up project files and panel firmware.

w w w . a u t o m a t i o n d i r e c t . c o m / C - m o r e eCR-35 Book 1 (14.3)

Prices as of April 15, 2015. Check Web site for most current prices.

C-more Operator Touch Panels

Company Information

Control Systems Overview

CLICK PLC

Do-More PLCs Overview

Do-More H2

PLC

Do-More T1H

PLC

DirectLOGIC PLCs Overview

DirectLOGIC

DL05/06

DirectLOGIC

DL105

DirectLOGIC

DL205

DirectLOGIC

DL305

DirectLOGIC

DL405

Productivity Controller Overview

Productivity

Universal Field I/O

Software

C-More

HMI

C-More Micro

HMI

ViewMarq Industrial Marquees

Other HMI

Communications

Appendix Book 1

Terms and Conditions http://www.automationdirect.com/pn/EA9-T6CL-R http://www.automationdirect.com/pn/EA9-T12CL http://www.automationdirect.com/pn/EA9-T15CL http://www.automationdirect.com/pn/EA9-T12CL http://www.automationdirect.com/pn/EA9-T15CL http://www.automationdirect.com/pn/USB-FLASH

C-more Communication Protocols & Cables Compatibility Table

PLC Family Model Protocols

Allen-Bradley

MicroLogix 1000, 1100, 1200, 1400, 1500, SLC 5-/01/02/03 DH485/AIC/AIC+

MicroLogix 1000, 1100, 1200, 1400 and 1500 DF1 Half Duplex; DF1 Full DuplexSLC 5-/03/04/05

ControlLogix™, CompactLogix™, FlexLogix™ PLC-5 DF1 Full Duplex ControlLogix, CompactLogix, FlexLogix - Tag Based DF1 Half Duplex; DF1 Full Duplex ControlLogix, CompactLogix, FlexLogix - Generic I/O Messaging EtherNet/IP Server

ControlLogix, CompactLogix, FlexLogix - Tag Based

EtherNet/IP Client Micrologix 1100, 1400 & SLC5/05, all via native Ethernet port MicroLogix 1000, 1100, 1200, 1400,1500 & SLC 5-03/04/05, all via ENI Adapter

Micro 800 series Modbus RTU Modbus TCP

Modbus RTU Modbus RTU devices Modbus RTU Modbus TCP/IP Modbus TCP/IP devices Modbus TCP/IP GE 90/30, 90/70, Micro 90, VersaMax Micro SNPX

Mitsubishi

FX Series FX Direct

Q02, Q02H, Q06H, Q12H, Q25H Q CPU

Q, QnA Serial QnA Serial Q, QnA Ethernet QnA Ethernet

Omron C200 Adapter, C500 Host Link CJ1/CS1 Serial, CJ1/CS1 Ethernet FINS

Modicon 984 CPU, Quantum 113 CPU, AEG Modicon Micro Series 110 CPU: 311-xx, 411-xx, 512-xx, 612-xx Modbus RTU

Siemens S7-200 CPU, RS-485 Serial PPI

S7-200 CPU, S7-300 CPU, S7-400, S7-1200 CPU;

Ethernet Ethernet ISO over TCP

Productivity Series all

AutomationDirect P3000 Serial AutomationDirect P3000 Ethernet

Do-more all Do-more Serial Do-more Ethernet

CLICK all AutomationDirect Modbus (CLICK)

Direct LOGIC

DL05/DL06

all

K-Sequence Direct NET Modbus (Koyo addressing)

H0-ECOM/H0-ECOM100 Direct LOGIC Ethernet DL105 all K-Sequence

DL205

D2-230 K-Sequence

D2-240 K-Sequence Direct NET

D2-250/D2-250-1/D2-260 K-Sequence Direct NET Modbus (Koyo addressing)

D2-240/D2-250-1/D2-260 using D2-DCM

Direct NET Modbus (Koyo addressing)

H2-ECOM/H2-ECOM100 Direct LOGIC Ethernet

DL305

D3-330/330P (Requires the use of a Data Communications Unit)

Direct NET

D3-340 Direct NET

D3-350 K-Sequence Direct NET Modbus (Koyo addressing)

D3-350 using D3-DCM Direct NET Modbus (Koyo addressing)

DL405

D4-430 K-Sequence Direct NET

D4-440 K-Sequence Direct NET

D4-450 K-Sequence Direct NET Modbus (Koyo addressing)

All with D4-DCM Direct NET Modbus (Koyo addressing)

H4-ECOM/H4-ECOM100 Direct LOGIC Ethernet H2-WinPLC (Think & Do) Live V5.2 or later and Studio any version

Think & Do Modbus RTU (serial port)

H2-WinPLC (Think & Do) Live V5.5.1 or later and Studio V7.2.1 or later

Think & Do Modbus TCP/IP (Ethernet port)

EA-2CBL

EA-2CBL-1

Cable Description

Cable Part Number Price

AutomationDirect Productivity Series, Do-more, CLICK, Direct LOGIC PLC RJ-12 port, DL05, DL06, DL105, DL205, D3-350, D4-450 & H2-WinPLC (RS-232C)

EA-2CBL $20.00

Direct LOGIC (VGA Style) 15-pin port, DL06, D2-250

(250-1), D2-260 (RS-232C)

EA-2CBL-1 $20.00

Direct LOGIC PLC RJ-11 port, D3-340 (RS-232C) EA-3CBL $20.00

Direct LOGIC DL405 PLC 15-pin D-sub port, DL405

(RS-232C)

EA-4CBL-1 $20.00

Direct LOGIC PLC 25-pin D-sub port, DL405, D3-350, DL305 DCU and all DCM’s (RS-232C)

EA-4CBL-2 $20.00

Allen-Bradley MicroLogix 1000, 1100, 1200, 1400 & 1500

(RS-232C)

EA-MLOGIX-CBL $30.00

Allen-Bradley SLC 5-03/04/05 ControlLogix, CompactLogix, FlexLogix, DF1 port (RS-232C)

EA-SLC-232-CBL $20.00

Allen-Bradley PLC-5 DF1 port

(RS-232C)

EA-PLC5-232-CBL $20.00

Allen-Bradley SLC 500 DH485 port

(RS-485A)

EA-DH485-CBL $20.00

GE 90/30, 90/70, Micro 90, VersaMax Micro 15-pin D-sub port (RS-422A)

EA-90-30-CBL $20.00

MITSUBISHI FX Series 25-pin port

(RS-422A)

EA-MITSU-CBL $20.00

MITSUBISHI FX Series 8-pin mini-DIN

(RS-422A)

EA-MITSU-CBL-1 $20.00

OMRON Host Link C200 Adapter, C500

(RS-232C)

EA-OMRON-CBL $20.00

Example Cables:

1 - 8 0 0 - 6 3 3 - 0 4 0 5eCR-36 Book 1 (14.3)

Prices as of April 15, 2015. Check Web site for most current prices.

C-more Operator Touch Panels http://www.automationdirect.com/pn/EA-PLC5-232-CBL http://www.automationdirect.com/pn/EA-SLC-232-CBL http://www.automationdirect.com/pn/EA-MITSU-CBL-1 http://www.automationdirect.com/pn/EA-MLOGIX-CBL http://www.automationdirect.com/pn/EA-DH485-CBL http://www.automationdirect.com/pn/EA-90-30-CBL http://www.automationdirect.com/pn/EA-MITSU-CBL http://www.automationdirect.com/pn/EA-OMRON-CBL http://www.automationdirect.com/pn/H0-ECOM100 http://www.automationdirect.com/pn/H2-ECOM100 http://www.automationdirect.com/pn/H4-ECOM100 http://www.automationdirect.com/pn/EA-2CBL-1 http://www.automationdirect.com/pn/EA-2CBL-1 http://www.automationdirect.com/pn/EA-4CBL-1 http://www.automationdirect.com/pn/EA-4CBL-2 http://www.automationdirect.com/pn/D2-250-1 http://www.automationdirect.com/pn/D2-250-1 http://www.automationdirect.com/pn/H0-ECOM http://www.automationdirect.com/pn/H2-ECOM http://www.automationdirect.com/pn/H4-ECOM http://www.automationdirect.com/pn/EA-2CBL http://www.automationdirect.com/pn/EA-2CBL http://www.automationdirect.com/pn/EA-3CBL http://www.automationdirect.com/pn/D2-230 http://www.automationdirect.com/pn/D2-240 http://www.automationdirect.com/pn/D2-260 http://www.automationdirect.com/pn/D2-240 http://www.automationdirect.com/pn/D2-260 http://www.automationdirect.com/pn/D2-DCM http://www.automationdirect.com/pn/D3-330 http://www.automationdirect.com/pn/D3-340 http://www.automationdirect.com/pn/D3-350 http://www.automationdirect.com/pn/D3-350 http://www.automationdirect.com/pn/D3-DCM http://www.automationdirect.com/pn/D4-430 http://www.automationdirect.com/pn/D4-440 http://www.automationdirect.com/pn/D4-450 http://www.automationdirect.com/pn/D4-DCM http://www.automationdirect.com/pn/D3-350 http://www.automationdirect.com/pn/D4-450 http://www.automationdirect.com/pn/D2-260 http://www.automationdirect.com/pn/D3-340 http://www.automationdirect.com/pn/D3-350

Using the C-more Programming Software EA9-PGMSW for project development, the touch panel can be connected to a PC (personal computer) in one of several ways:

• Connect a USB Programming Cable such as (USB-CBL-AB15) from a USB port type A on the PC to the USB type B programming port on the C-more touch panel. The USB connection is for direct connection only and does not support USB hubs.

• Connect the C-more touch panel to a PC with a Cat5 Ethernet cable via an Ethernet switch.

Multiple panels can be programmed in this configuration.

Following are the minimum system requirements for running C-more Programming Software, p/n EA9-PGMSW, on a PC:

• USB or Ethernet connection to touch panel (cables sold separately).

• Operating System - Windows 7 (Pro, Ultimate, 32 or 64-bit) or Windows 8 (Pro, Ultimate, 32 or

64-bit)

USB-CBL-ABxx USB Cable

PC C-more Touch Panel

USB

Port

USB

Port

USB Connectivity

Stride™ Ethernet Switch 10/100 Base-T

(such as SE-SW5U)PC

C-more Touch Panel

Ethernet Port

Ethernet CAT5 Cable Auto MDI / MD-X

Ethernet Port

Ethernet Connectivity via a Hub or Switch

Ethernet CAT5 Cable

C-more Touch Panel

Ethernet Port

PC

Auto MDI / MD-X Ethernet Port

Ethernet Direct Connection

Message in from a device

Message is sent out only from the port connected to destination device

Part No. SE-SW5U

Stride™ Ethernet Switch

USB Programming Cable

Part No. USB-CBL-AB15

C-more Computer Programming Connections

$22.50

$99.00

Other lengths available see

USB-CBL-AB3, USB-CBL-AB6, USB-CBL-AB10

NOTE: Regarding Ethernet access to a C-more panel.

If you intend to take advantage of the methods of remote access to the panel, including the web server, PC remote access, FTP, iPhone or iPad app, you need to consider the security exposure in order to minimize the risks to your process and your C-more panel.

Security measures may include password protection, changing the ports exposed on your network, including a VPN in your network, and other methods. Security should always be carefully evaluated for each installation.

w w w . a u t o m a t i o n d i r e c t . c o m / C - m o r e eCR-37 Book 1 (14.3)

Prices as of April 15, 2015. Check Web site for most current prices.

C-more Operator Touch Panels

Company Information

Control Systems Overview

CLICK PLC

Do-More PLCs Overview

Do-More H2

PLC

Do-More T1H

PLC

DirectLOGIC PLCs Overview

DirectLOGIC

DL05/06

DirectLOGIC

DL105

DirectLOGIC

DL205

DirectLOGIC

DL305

DirectLOGIC

DL405

Productivity Controller Overview

Productivity

Universal Field I/O

Software

C-More

HMI

C-More Micro

HMI

ViewMarq Industrial Marquees

Other HMI

Communications

Appendix Book 1

Terms and Conditions http://www.automationdirect.com/pn/USB-CBL-AB15 http://www.automationdirect.com/pn/USB-CBL-AB15 http://www.automationdirect.com/pn/USB-CBL-AB10 http://www.automationdirect.com/pn/USB-CBL-AB3 http://www.automationdirect.com/pn/USB-CBL-AB6 http://www.automationdirect.com/pn/EA9-PGMSW http://www.automationdirect.com/pn/EA9-PGMSW http://www.automationdirect.com/pn/SE-SW5U http://www.automationdirect.com/pn/SE-SW5U

Providing Power to the Touch Panel

• Connect a dedicated 12–24 VDC Class 2 power supply to the DC connector on the rear of the C-more…

This is the start of the file's text. The full file is on GovTribe.