COLLECTIVE TRAINING FACILITY (CTF)
VIRGINIA ARMY NATIONAL GUARD
FORT PICKETT – BLACKSTONE, VIRGINIA
PROJECT # 510307
TOILET COMPARTMENTS 102113 - 1
SECTION 102113 - TOILET COMPARTMENTS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Solid-polymer toilet compartments configured as toilet enclosures and urinal screens.
1.2 SUBMITTALS
A. Product Data: For each type of product indicated.
B. LEED Submittals:
1. Product Data for Credit MR 4.1 and Credit MR 4.2: For products having recycled content, documentation indicating percentages by weight of postconsumer and preconsumer recycled content. Include statement indicating costs for each product having recycled content.
C. Shop Drawings: For toilet compartments. Include plans, elevations, sections, details, and attachments to other work.
D. Samples for each exposed product and for each color and texture specified.
E. Product certificates.
F. Maintenance data.
1.3 QUALITY ASSURANCE
A. Surface-Burning Characteristics: As determined by testing identical products according to ASTM E 84, or another standard acceptable to authorities having jurisdiction, by a qualified testing agency. Identify products with appropriate markings of applicable testing agency.
1. Flame-Spread Index: 75 or less.
2. Smoke-Developed Index: 450 or less.
B. Regulatory Requirements: Comply with applicable provisions in the U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA) and Architectural Barriers Act (ABA) Accessibility Guidelines for Buildings and Facilities" and ICC/ANSI A117.1 for toilet compartments designated as accessible.
TOILET COMPARTMENTS 102113 - 2
PART 2 - PRODUCTS
2.1 MATERIALS
A. Steel Sheet: Commercial steel sheet for exposed applications; mill phosphatized and selected for smoothness.
1. Electrolytically Zinc Coated: ASTM A 879/A 879M, 01Z (03G).
2. Hot-Dip Galvanized: ASTM A 653/A 653M, either hot-dip galvanized or galvannealed.
B. Zamac: ASTM B 86, commercial zinc-alloy die castings.
2.2 SOLID-POLYMER UNITS
A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
1. Accurate Partitions Corporation.
2. Ampco, Inc.
3. Bradley Corporation; Mills Partitions.
4. Comtec Industries/Capitol Partitions.
5. General Partitions Mfg. Corp.
6. Global Steel Products Corp.
7. Hadrian Manufacturing Inc.
8. Knickerbocker Partition Corporation.
9. Metpar Corp.
10. Partition Systems Incorporated of South Carolina.
11. Rockville Partitions Incorporated.
12. Santana Products, Inc.
13. Sanymetal; a Crane Plumbing company.
14. Weis-Robart Partitions, Inc.
B. Toilet-Enclosure Style: Overhead braced.
C. Urinal-Screen Style: Wall hung.
D. Door, Panel, and Pilaster Construction: Solid, high-density polyethylene (HDPE) or polypropylene (PP) panel material, not less than 1 inch (25 mm) thick, seamless, with eased edges, no-sightline system, and with homogenous color and pattern throughout thickness of material.
1. Integral Hinges: Configure doors and pilasters to receive integral hinges.
2. Heat-Sink Strip: Manufacturer's standard continuous, strip fastened to exposed bottom edges of solid-polymer components to prevent burning.
3. Polymer Panel Finish: One color and pattern in each room.
a. Color and Pattern: As selected by Architect from manufacturer's full range.
TOILET COMPARTMENTS 102113 - 3
E. Pilaster Shoes and Sleeves (Caps): Manufacturer's standard design; stainless steel.
F. Urinal-Screen Post: Manufacturer's standard post design of material matching the thickness and construction of pilasters; with shoe matching that on the pilaster.
G. Brackets (Fittings):
1. Full-Height (Continuous) Type: Manufacturer's standard design; extruded aluminum.
2.3 ACCESSORIES
A. Hardware and Accessories: Manufacturer's standard design, heavy-duty operating hardware and accessories.
1. Material: Clear-anodized aluminum.
2. Hinges: Manufacturer's standard paired, self-closing type that can be adjusted to hold doors open at any angle up to 90 degrees.
3. Latch and Keeper: Manufacturer's standard surface-mounted latch unit designed for emergency access and with combination rubber-faced door strike and keeper. Provide units that comply with regulatory requirements for accessibility at compartments designated as accessible.
4. Coat Hook: Manufacturer's standard combination hook and rubber-tipped bumper, sized to prevent in-swinging door from hitting compartment-mounted accessories.
5. Door Bumper: Manufacturer's standard rubber-tipped bumper at out-swinging doors.
6. Door Pull: Manufacturer's standard unit at out-swinging doors that complies with regulatory requirements for accessibility. Provide units on both sides of doors at compartments designated as accessible.
B. Overhead Bracing: Manufacturer's standard continuous, extruded-aluminum head rail with antigrip profile and in manufacturer's standard finish.
C. Anchorages and Fasteners: Manufacturer's standard exposed fasteners of stainless steel or chrome-plated steel or brass, finished to match the items they are securing, with theft-resistant-type heads. Provide sex-type bolts for through-bolt applications. For concealed anchors, use stainless steel, hot-dip galvanized steel, or other rust-resistant, protective-coated steel.
2.4 FABRICATION
A. Overhead-Braced Units: Provide manufacturer's standard corrosion-resistant supports, leveling mechanism, and anchors at pilasters to suit floor conditions. Provide shoes at pilasters to conceal supports and leveling mechanism.
B. Urinal-Screen Posts: Provide manufacturer's standard corrosion-resistant anchoring assemblies with leveling adjustment at bottoms of posts. Provide shoes at posts to conceal anchorage.
C. Door Size and Swings: Unless otherwise indicated, provide 24-inch- (610-mm-) wide, in-swinging doors for standard toilet compartments and 36-inch- (914-mm-) wide, out-swinging doors with a minimum 32-inch- (813-mm-) wide, clear opening for compartments designated as accessible.
TOILET COMPARTMENTS 102113 - 4
PART 3 - EXECUTION
3.1 INSTALLATION
A. General: Comply with manufacturer's written installation instructions. Install units rigid, straight, level, and plumb. Secure units in position with manufacturer's recommended anchoring devices.
B. Clearances: Maximum 1/2 inch (13 mm) between pilasters and panels; 1 inch (25 mm) between panels and walls.
3.2 ADJUSTING
A. Hardware Adjustment: Adjust and lubricate hardware according to hardware manufacturer's written instructions for proper operation. Set hinges on in-swinging doors to hold doors open approximately 30 degrees from closed position when unlatched. Set hinges on out-swinging doors to return doors to fully closed position.
END OF SECTION 102113
| PART 1 - GENERAL |
| 1.1 SUMMARY |
| A. Section Includes: |
| 1. Solid-polymer toilet compartments configured as toilet enclosures and urinal screens. |
| 1.2 SUBMITTALS |
| A. Product Data: For each type of product indicated. |
| B. LEED Submittals: |
| 1. Product Data for Credit MR 4.1 and Credit MR 4.2: For products having recycled content, documentation indicating percentages by weight of postconsumer and preconsumer recycled content. Include statement indicating costs for each product having re... |
| C. Shop Drawings: For toilet compartments. Include plans, elevations, sections, details, and attachments to other work. |
| D. Samples for each exposed product and for each color and texture specified. |
| E. Product certificates. |
| F. Maintenance data. |
| 1.3 QUALITY ASSURANCE |
| A. Surface-Burning Characteristics: As determined by testing identical products according to ASTM E 84, or another standard acceptable to authorities having jurisdiction, by a qualified testing agency. Identify products with appropriate markings of ... |
| 1. Flame-Spread Index: 75 or less. |
| 2. Smoke-Developed Index: 450 or less. |
B. Regulatory Requirements: Comply with applicable provisions in the U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA) and Architectural Barriers Act (ABA) Accessibility Guidelines for Buildings an...
| PART 2 - PRODUCTS |
| 2.1 MATERIALS |
| A. Steel Sheet: Commercial steel sheet for exposed applications; mill phosphatized and selected for smoothness. |
| 1. Electrolytically Zinc Coated: ASTM A 879/A 879M, 1T01Z1T4T (03G)4T. |
| 2. Hot-Dip Galvanized: ASTM A 653/A 653M, either hot-dip galvanized or galvannealed. |
B. Zamac: ASTM B 86, commercial zinc-alloy die castings.
| 2.2 SOLID-POLYMER UNITS |
| A. Manufacturers: Subject to compliance with requirements, provide products by one of the following: |
| 1. Accurate Partitions Corporation. |
| 2. Ampco, Inc. |
| 3. Bradley Corporation; Mills Partitions. |
| 4. Comtec Industries/Capitol Partitions. |
| 5. General Partitions Mfg. Corp. |
| 6. Global Steel Products Corp. |
| 7. Hadrian Manufacturing Inc. |
| 8. Knickerbocker Partition Corporation. |
| 9. Metpar Corp. |
| 10. Partition Systems Incorporated of South Carolina. |
| 11. Rockville Partitions Incorporated. |
| 12. Santana Products, Inc. |
| 13. Sanymetal; a Crane Plumbing company. |
| 14. Weis-Robart Partitions, Inc. |
| B. Toilet-Enclosure Style: Overhead braced. |
| C. Urinal-Screen Style: Wall hung. |
| D. Door, Panel, and Pilaster Construction: Solid, high-density polyethylene (HDPE) or polypropylene (PP) panel material, not less than 1T1 inch1T4T (25 mm)4T thick, seamless, with eased edges, no-sightline system, and with homogenous color and patter... |
| 1. Integral Hinges: Configure doors and pilasters to receive integral hinges. |
| 2. Heat-Sink Strip: Manufacturer's standard continuous, strip fastened to exposed bottom edges of solid-polymer components to prevent burning. |
| 3. Polymer Panel Finish: One color and pattern in each room. |
| a. Color and Pattern: As selected by Architect from manufacturer's full range. |
| E. Pilaster Shoes and Sleeves (Caps): Manufacturer's standard design; stainless steel. |
| F. Urinal-Screen Post: Manufacturer's standard post design of material matching the thickness and construction of pilasters; with shoe matching that on the pilaster. |
| G. Brackets (Fittings): |
| 1. Full-Height (Continuous) Type: Manufacturer's standard design; extruded aluminum. |
| 2.3 ACCESSORIES |
| A. Hardware and Accessories: Manufacturer's standard design, heavy-duty operating hardware and accessories. |
| 1. Material: Clear-anodized aluminum. |
| 2. Hinges: Manufacturer's standard paired, self-closing type that can be adjusted to hold doors open at any angle up to 90 degrees. |
| 3. Latch and Keeper: Manufacturer's standard surface-mounted latch unit designed for emergency access and with combination rubber-faced door strike and keeper. Provide units that comply with regulatory requirements for accessibility at compartments ... |
| 4. Coat Hook: Manufacturer's standard combination hook and rubber-tipped bumper, sized to prevent in-swinging door from hitting compartment-mounted accessories. |
| 5. Door Bumper: Manufacturer's standard rubber-tipped bumper at out-swinging doors. |
| 6. Door Pull: Manufacturer's standard unit at out-swinging doors that complies with regulatory requirements for accessibility. Provide units on both sides of doors at compartments designated as accessible. |
| B. Overhead Bracing: Manufacturer's standard continuous, extruded-aluminum head rail with antigrip profile and in manufacturer's standard finish. |
| C. Anchorages and Fasteners: Manufacturer's standard exposed fasteners of stainless steel or chrome-plated steel or brass, finished to match the items they are securing, with theft-resistant-type heads. Provide sex-type bolts for through-bolt applic... |
| 2.4 FABRICATION |
| A. Overhead-Braced Units: Provide manufacturer's standard corrosion-resistant supports, leveling mechanism, and anchors at pilasters to suit floor conditions. Provide shoes at pilasters to conceal supports and leveling mechanism. |
| B. Urinal-Screen Posts: Provide manufacturer's standard corrosion-resistant anchoring assemblies with leveling adjustment at bottoms of posts. Provide shoes at posts to conceal anchorage. |
| C. Door Size and Swings: Unless otherwise indicated, provide 1T24-inch-1T4T (610-mm-)4T wide, in-swinging doors for standard toilet compartments and 1T36-inch-1T4T (914-mm-)4T wide, out-swinging doors with a minimum 1T32-inch-1T4T (813-mm-)4T wide, c... |
| PART 3 - EXECUTION |
| 3.1 INSTALLATION |
| A. General: Comply with manufacturer's written installation instructions. Install units rigid, straight, level, and plumb. Secure units in position with manufacturer's recommended anchoring devices. |
| B. Clearances: Maximum 1T1/2 inch1T4T (13 mm)4T between pilasters and panels; 1T1 inch1T4T (25 mm)4T between panels and walls. |
| 3.2 ADJUSTING |
| A. Hardware Adjustment: Adjust and lubricate hardware according to hardware manufacturer's written instructions for proper operation. Set hinges on in-swinging doors to hold doors open approximately 30 degrees from closed position when unlatched. S... |