Question__26_Comparison_of_listed_properties.pdf

PDF 44 KB Posted

Attached to
MATOC DPW - USAG Hawaii Federal contract opportunity
Solicitation number
W912CN18R0012
Issued by
Department of the Army Materiel Command Expeditionary Contracting Command Regional Contracting Office Hawaii 413th CSB

About this file

This document provides details on a federal contract opportunity for real property repair, maintenance and minor construction services on the islands of Oahu and Hawaii. The solicitation will result in multiple award task order contracts with a minimum of four awards set aside for women-owned small businesses. The contracts will have a one year base period plus four one-year options, with a minimum guarantee of $20,000 for each contract holder during the base and option periods. Bids must include a minimum guarantee of $3,000,000 to be eligible for award. The total value of task orders awarded to any one contractor cannot exceed $92,400,000. The solicitation is expected to be released by the Department of the Army Materiel Command Expeditionary Contracting Command Regional Contracting Office Hawaii under NAICS code 236220 for commercial and institutional building construction.

Attachment to Question #26

View the file

Other files for this federal contract opportunity

Other files attached to MATOC DPW - USAG Hawaii, newest first.
File Type Posted
18-R-0012__0005__SF30__Amendment.pdf PDF
18-R-0012__0005__Conformed_Solicitation.pdf PDF
18-R-0012__0004__SF30__Amendment.pdf PDF
Floor_mount_receptacle_cover.pptx PPTX presentation
ATTACHMENT_4a_COVER_LETTER_REVISED.pdf PDF
18-R-0012__0004__Conformed_Solicitation.pdf PDF
SB_488_LBP_lab_analysis.pdf PDF
Question__26_SIGNA_cut-sheet.pdf PDF
18-R-0012__0003__Conformed_Solicitation.pdf PDF
SB_488_ASB_lab_analysis.pdf PDF
2a_-_Exh_2_Revised_SOW__Bldg_488_SB.PPT PPT presentation
Window_Supplier_BLDG_488_Weight_Room.pdf PDF
Question__26_HERCULAN_MF_System_cut-sheet.pdf PDF
DPW_Design_guidelines_for_AC.DOC DOC document
Question__26_SIGNA_Floor.pdf PDF
18-R-0012__0003__SF30__Amendment.pdf PDF
SIGNA_Floor.docx DOCX document
Question__26_HERCULAN_MF_7+2_Specs.pdf PDF
85532017_-_As_Builts.pdf PDF
Drain_Cover_Specification.pdf PDF
87279002_-_As_Builts.pdf PDF
ATTACHMENT_4a_COVER_LETTER.pdf PDF
18-R-0012__0001__Conformed_Solicitation.pdf PDF
18-R-0012__0002__Conformed_Solicitation.pdf PDF
18-R-0012__0001__SF30__Amendment.pdf PDF
18-R-0012__0002__SF30__Amendment.pdf PDF
18-R-0012.pdf PDF
ATTACHMENT_3_PAST_PERFORMANCE_INFORMATION.docx DOCX document
Attachment_1.A_COST_ESTIMATE_SUMMARY_SHEET.xlsx XLSX spreadsheet
ATTACHMENT_4._PAST_PERFORMANCE_EVALUATION_QUESTIONNAIRE.docx DOCX document
ATTACHMENT_1.__PROPOSAL_COST_BREAKDOWN_INSTRUCTIONS.docx DOCX document
Attachment_2_SOW_Bldg_488_SB_(Seed_Project).PPT PPT presentation
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Comparison of listed properties:

Signaflor 9mm standard thickness pad-n-pour system from Signature Sports Flooring

TECHNICAL SPECIFICATIONS

Shore A hardness 80 Tensile strength DIN 53504 N/mm 2 7.0 Elongation at break DIN 53504 150%

Shock Absorbtion min. 51 (Cat. 1) min. 45 (Cat. 2):

7mm = 28%, 9mm = 32%, 4mm+14%

Rolling Load 1000 N Remaining indentation max. 0.5mm 7mm+0.17, 9mm = 0.37, 4mm = 0.21 Ball rebound min. 90% 99.0% (4,7, and 9) Sliding coefficient 0.4-0.6mm 7mm=0.50, 9mm=0.44, 4mm=0.43

Herculan 7+2 multipurpose floor system (9mm)—taken from attached cut-sheet

MF Surface Hardness (DIN 53505, ASTM D-2240) Shore A=82 +/- Impact Resistance (EN 1517-1999, DIN 18032) 11Nm Resistance - Static Load (24 Hrs) 25 Kg/cm sq Tensile Strength (EN ISO 527-1, DIN 53455) 8.3 N/mm sq Elongation at Break (EN ISO 527-1, DIN 54455) 140% Tear Strength (DIN 53515) 23 N/mm Friction (DIN 18032) 0.46

As you can see, the measured characteristics of the Signaflor are matched or exceeded in the Herculan system.