Am_0004-Vol II-MPF-DWG.pdf

PDF 121 KB Posted

Attached to
B-21 MPF/FTD Construction Federal contract opportunity
Solicitation number
W9128F21R0032
Issued by
Department of the Army Corps of Engineers Engineering District Omaha

About this file

This document contains construction plans and specifications for a federal solicitation. The solicitation seeks a contractor to construct a B-21 Mission Operations Planning Facility and Field Detachment Training Facility at Ellsworth Air Force Base in South Dakota. The MPF will provide approximately 47,113 square feet of secure operations planning space, while the FTD will provide approximately 57,328 square feet of secure maintenance training and classroom space to support B-21 operations at the base and across the Air Force. The projects include spaces built to Intelligence Community Directive/Intelligence Community Standard 705 secure area standards and associated site work, utilities, and infrastructure for B-21 operations planning. The solicitation also includes options for fixtures, furnishings and equipment, intrusion detection and access control systems, an uninterruptted power supply, and closed-circuit television. The construction plans provide technical details for electrical power and communication device locations.

View the file

Other files for this federal contract opportunity

Other files attached to B-21 MPF/FTD Construction, newest first.
File Type Posted
Am_0012.pdf PDF
Am_0011.pdf PDF
Am_0010_Dwgs_FTD.pdf PDF
Am_0010.pdf PDF
Am_0010_Dwgs_MPF.pdf PDF
Am_0009.pdf PDF
Am_0009.pdf PDF
Am_0008.pdf PDF
EAFB B-21 FTD AM-0008 Dwgs_Vol2.pdf PDF
EAFB B-21 MPF AM-0008 Dwgs_Vol2.pdf PDF
Am_0007.pdf PDF
EAFB B-21 FTD AM-0007 Dwgs_Vol2.pdf PDF
EAFB B-21 FTD AM-0007 Dwgs_Vol1.pdf PDF
EAFB B-21 MPF AM-0007 Dwgs_Vol2.pdf PDF
Am_0006.pdf PDF
EAFB B-21 FTD AM-0006 Dwgs_Vol1.pdf PDF
EAFB B-21 FTD AM-0006 Dwgs_Vol2.pdf PDF
Am_0005.pdf PDF
Am_0005-Vol II-MPF-DWG.pdf PDF
Am_0005-Vol II-FTD-DWG.pdf PDF
Am_0004.pdf PDF
Am_0004-Vol II-FTD-DWG.pdf PDF
Am_0003.pdf PDF
Am_0002.pdf PDF
Am_0001.pdf PDF
95-Percent_DWGS_VOL2_W9128F21R0080_B21-FTD.pdf PDF
W9128F-21-R-0032_VOL3 - FTD Only Specs.pdf PDF
00 21 00 AT2 FTD Site Photo Survey (under separate cover_electronic only - 1 of 1).zip ZIP file
W9128F-21-R-0032_VOL1-Front End and Site Specs.pdf PDF
95-Percent_DWGS_VOL1_W9128F21R0080_B21-FTD.pdf PDF
W9128F-21-R-0032_VOL2 - MPF Only Specs.pdf PDF
Show all 31

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GL-129-1-10

GFI

FRIDGE

48" AFF

GL-129-1-20

GFI

FRIDGE

48" AFF

GL-129-1-16

GFI

MIC

42" AFF

GL-129-1-18

GFI

MIC

60" AFF

GL-129-1-14

GFI

COFFEE

42" AFF

GL-129-1-12

GFI

GL-129-1-12

GFI

42" AFF

GL-129-1-12

GFI

42" AFF

GL-108-1-7

GFI

GL-108-1-5

GFI

MICROWAVE

42" AFF

GL-108-1-35

GFI

FRIDGE

GL-108-1-7

GFI

42" AFF

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

M R

IV

E

R S

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

M

IS

S

IO

N

O P

E R

A T

IO

N

S P

L A

N N

IN

G

F A

C

IL

IT

Y

M

P F

N

O V

E M

B E

R

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

MPF

EP301

P O

W E

R E

L E

V A

T

IO

N P

L A

N S

W S

C H

W E

IT

Z

E R

D B

R A

D L E

Y

T M

O R

G A

N

SCALE: 1/2" = 1'-0"

K1

POWER ELEVATION - BREAK 121

0 4' 8' 16'

GENERAL SHEET NOTES

1. REFER TO E-001 AND E-002 FOR LEGEND, SYMBOLS, AND

GENERAL NOTES.

2. REFER TO SHEET EP601 FOR POWER DISTRIBUTION ONE

LINE DIAGRAM.

3. PROVIDE DEDICATED NEUTRAL CONDUCTORS FOR ALL

LIGHTING AND POWER BRANCH CIRCUITS REQUIRING A

NEUTRAL CONDUCTOR. SHARED NEUTRALS WILL NOT BE

ALLOWED EXCEPT WHERE NOTED FOR FURNITURE

CONNECTIONS.

4. COMMUNICATION DEVICES SHOWN AS GRAYSCALE ARE

FOR COORDINATION PURPOSES. DEVICES SHALL BE

INSTALLED SUCH THAT THEY ARE ADJACENT TO THE

COMMUNICATION DEVICE.

5. PROVIDE 4" MINIMUM HOUSEKEEPING PAD UNDER ALL

FLOOR MOUNTED ELECTRICAL EQUIPMENT. SEE

STRUCTURAL DRAWINGS FOR DETAILS.

6. TYPICAL ALL RECESSED DEVICES IN STC RATED WALLS,

REFER TO EP503 FOR INSTALLATION REQUIREMENTS.

7. REFER TO LIFE SAFETY DRAWINGS FOR FIRE AND SMOKE

RATED WALL LOCATIONS. REFER TO ARCHITECTURAL

DRAWINGS FOR STC RATED WALL LOCATIONS.

8. ASHRAE 90.1, AUTOMATIC RECEPTACLE CONTROL, REFER

TO EL604 LIGHTING CONTROL SCHEDULES AND DETAIL

A9/EL602 FOR RECEPTACLE CONTROL REQUIREMENTS.

9. REFER TO MECHANICAL/ELECTRICAL CONNECTION

SCHEDULE FOR MECHANICAL EQUIPMENT CONNECTION

REQUIREMENTS, SHEET EP710.

SCALE: 1/2" = 1'-0"

E1

POWER ELEVATION - MOTHERS 104

0 4' 8' 16'

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

N O

V

A

M E

N D

M E

N T

D E

C

Sheets
EP301 - POWER ELEVATION PLANS

File details come from the government source that posted it. Updated .