This solicitation is for construction services to replace medium voltage switchgear at the New Power Plant in Sault Sainte Marie, Michigan. The scope of work includes replacing existing 5kV switchgear and dry type transformers, along with associated cabling, generator transformers, benchboard modifications, new metering and control devices, protective relaying revisions, surge arrestors, and interface wiring. The project aims to increase reliability by replacing outdated equipment. Being waterbound, all mobilization must be via over-water transport provided by the Government or contractor. This is a full and open procurement requiring the HUBZone 10% price evaluation preference. The estimated cost is between $1-5 million. The NAICS code is 238210. Individual site visits will be scheduled between November 18, 2020 from 0700-1530 Eastern per the contact in FAR 52.236-27. Offerors must be SAM registered and the contractor must self-perform 25% of work.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C T S

PPT

U3A EXCITER

U3A PPT FUSE CUBICLE

PPT3A-Q1,2,3-SP3A

3AG1

SCALE: 3/16" = 1'-0"

PLAN - AUXILIARY TURBINE LEVEL, EL 587.50

KEY PLAN

F L

O W

F L

O W

STEEL FLOOR GRATE

NOTE 3

ENCLOSURE

NEW UL LISTED

NOTE 2

NOTE 5

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

D E

T R

O

IT

M

IC

H

IG

A N

D E

T R

O

IT

D

IS

T R

IC

P O

W E

R H

O U

S E

S A

IN

T M

A R

Y S F

A L L S C

A N

A L

S M

P -5 -6 -1 -A -0

/1

D

D

IN

H U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

E-101

B

M A

S O

U M

P A

N A

H

E

V A

U G

H N

IN

S

T A

L L

A N

S I

D

NOTES:

REFERENCES:

N

S M

P -5 .0

E -1

X X

X .d g n

N

K

V S

W

IT

C H

G E

A R T

R A

N S

F O

R M

E R T

A

A U

X

IL

IA

R Y T

U R

B

IN

E P

L A

N V

IE

W E

L

.5

K

V S

W

IT

C H

G E

A R

S A

IN

T M

A R

Y S R

IV

E R

W

X K -2

-R -0

/0

/1

S T

E V

E N R

M

IL

E S P .E

CABLING.

5. REPLACE U3A CURRENT TRANSFORMERS AND ASSOCIATED

DESIGN AND MANUFACTURED EQUIPMENT DIMENSIONS.

4. LAYOUT SHOWN IS CONCEPTUAL AND SUBJECT TO CONTRACTOR

GENERATOR HOUSING.

3. REPLACE U3A CABLES UP TO FIRST TERMINATION INSIDE

2. REPLACE GROUND CABLE FROM U3A.

1. ITEMS IN BOLD/RED INDICATE EQUIPMENT TO BE INSTALLED.

D A

T E

A

M E

N D

M E

N T

A D

D E

D

N O

T E R

E F

D W

G

U3A NEUTRAL CTS

CONDUIT AND EQUIPMENT INCLUDING D1557605

AUX. TURBINE LEVEL EL 587.505KV SWGR NEW.dgn

TITLEDRAWING NUMBER

NOTES:

REFERENCE DRAWINGS:

RELAY BOARD ELEVATIONDC-179-35-01

TITLEDRAWING NUMBER

RTAC

UNIT 10 FDR

13.8KV FDR BKR CNTRL

PANEL 6

13.8KV FDR 4

4KV FEEDERS

4KV XFMRS

PANEL 5

13.8KV BUS TIE 2

13.8KV FDR 3

GENERATOR 3

PANEL 3

13.8/4KV XFMR

4KV BUS

GENERATOR 3A

PANEL 4

13.8KV FDR 2

GENERATOR 2

PANEL 2

13.8KV BUS TIE 1

13.8KV FDR 1

GENERATOR 1

PANEL 1

TRIM

TRIM

TRIM

"2' 0"1' 6"1' 6"1' 6"1' 6"1' 6"1' 6"

3"11' 0"

11' 6"

3"

NP67

NP70

NP63

TS TS

NP68 NP69

TS TS

NP71 NP72

TS TS

NP64 NP65

NP-BG NP-BH

NP-BI NP-BJ

NP-BE NP-BF

NP66

87B

DIFFERENTIAL

4KV BUS

SEL-587Z

DIFFERENTIAL

CANAL FEEDER 1

SEL-387L

DIFFERENTIAL

CANAL FEEDER 2

SEL-387L

RELAYS

DIFFERENTIAL

4KV

PANEL 0

NP60

NP59

NP61

NP62

VOLTMETER

DC BUS

YOKAGAWA DX2030

VOLTMETER

DETECTOR

GROUND

DC BUS

ELEVATION - RELAY BOARD FRONT VIEW

TS

TS

TS

TSTS

TS TS

TS TS

TSTS

TS TS

TSTS

TS

TS

TS

TS

TS

TS

TS

TS

TS

TS TS

TSTS

TS TS

TSTS

TS TS

TSTS

TS TS

TSTS

TS TS

TSTS

TS TS

TSTS

TS TS

TSTS

TS TS

TSTS

5C15C2

86B186B2

REMOTE I/O

FDR 4

REMOTE I/O

FDR 3

REMOTE I/O

FDR 2

REMOTE I/O

FDR 1

REMOTE I/O

UNIT 3

REMOTE I/O

UNIT 3A

NP1

NP2

NP3

NP4

NP5

NP6 NP7

NP-A NP-B

NP8 NP9

NP-DNP-C

NP10

NP11 NP12

NP6 NP7

NP-E NP-F

NP8 NP9

NP-G NP-H

NP13 NP14

NP15 NP16

NP-I NP-J

NP17 NP18

NP-K NP-L

NP19 NP20

NP21

NP22

NP23

NP24

NP-M

NP-N

NP-O

NP25

NP6 NP7

NP8 NP9

NP26

NP-P NP-Q

NP-R NP-S

NP15 NP16

NP17 NP18

NP-T NP-U

NP-WNP-V

NP27 NP28

NP29

NP22 NP23

NP24 NP30

NP-X NP-Y

NP-Z

NP31

NP6 NP7

NP8 NP9

NP32

NP15

NP16

NP17

NP33 NP34

NP35 NP36

NP37

NP22 NP23

NP24 NP30

NP38

NP6 NP7

NP8 NP9

NP39

NP15

NP16

NP17

NP40 NP41

NP42 NP43

NP44

NP45

NP46

NP6 NP7

NP8 NP9

NP15

NP16

NP17

NP22 NP23

NP24 NP30

NP47

NP48 NP49

NP50 NP51

NP52

1 2 3 4 5 6

10 11

12 11

9 9

12 12

9 9

12 12

14 15

12 11

18 15

12 11

10 11

12 11

10 10

10 10

10 10

18 15

14 15

15 18

14 15

10 10

12 11

10 10

12 11

NP-AA

NP-AB NP-AC

NP-AD NP-AE

NP-AF

NP-AG

NP-AH

NP-AI NP-AJ

NP-AK NP-AL

NP-AM NP-AN

NP-AO NP-AP

NP-AQ

NP-AR

NP-AS

NP-AT NP-AU

NP-AV NP-AW

NP-AX

NP-AY

NP-AZ

NP-BA NP-BB

NP-BC NP-BD

NP53 NP54 NP55 NP57NP56 NP58

CS4

87L

BF2

3A

5C 5C3

CS3

87L

CS2

87L

BF1

RS3A

RS3

RS2

CS1

87L

RS1

SS

XFMR

H&V

XFMR

4KV

FDR 1

4KV

FDR 2

U10

FDR

RTAC FDR 4

U3A U3

XFMR

TA

BUS

TIE 2

BUS

TIE 1

FDR 3 FDR 2 FDR 1

U2 U1

REM I/O

U10 FDR

(FUTURE)

SEL-751

COMP

WORKS

1. ITEMS IN BOLD/RED INDICATE EQUIPMENT TO BE INSTALLED.

2 WORK TO BE PERFORMED ACCORDING TO THE SEQUENCE OF WORK SPECIFICATION.

3. RENAME SEL-751 RELAY FOR COMP WORKS USE.

4. DEVICE NAMEPLATE INFORMATION WILL BE PROVIDED BY FIELD PERSONNEL

POST AWARD FOR CONTRACTOR TO FURNISH AND INSTALL.

5. ADD TERMINAL STRIPS FOR NEW TERMINATIONS AS REQUIRED AT REAR OF RELAY BOARD AT A

LOCATION APPROVED BY COR

SEE NOTE 7

SEE NOTES 4, 5 (TYP.)

SEE NOTE 8

8. PROVIDE NEW HINGED PANEL FRONT.

62-64" ABOVE FINISHED FLOOR.

7. LOCATE REINSTALLED YOKAGAWA DEVICE AT APPROXIMATELY

FOR NON-BIDDABLE INFORMATION REQUIRED FOR AS-BUILTS.

6. CONTRACTOR TO REQUEST DIGITAL SOURCE DRAWING FILES POST-AWARD

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

CERTIFIED FINAL - READY TO ADVERTISE

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

W

X K -2

-R -0

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

D E

T R

O

IT

M

IC

H

IG

A N

D E

T R

O

IT

D

IS

T R

V S

W

IT

C H

G E

A R

P O

W E

R H

O U

S E

S A

IN

T M

A R

Y S R

IV

E R

S A

IN

T M

A R

Y S F

A L L S C

A N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

IN

S

T A

L L

R E

L A

Y B

O A

R D L

A Y

O U

T

E L E

V A

T

IO

N

G P

Y L E

D

D

IN

H

A N

S I

D

E

V A

U G

H N

E-205

S M

P -5 .0

E -2

X X

X .d g n

S T

E V

E N R

M

IL

E S P .E

/0

/1

S M

P -5 -6 -1 -A -4

/7

/2

/2

A M

E N

D M

E N

T

C L

A R

IF

IE

D P

A N

E L R

E P

L A

C E

M E

N T S

C O

P E

STATION SERVICE

REFERENCE DRAWINGS:

NOTES:

FUTURE

128.6 RPM

pf = 0.91

4.16kV

2747 KVA

UNIT 3A

R = 2.32 OHM

4.16/240

5 KVA

CABLE

3/c 400 MCM

EG

480V BUS

SERVICE

STATION

4.16KV

480/

300KVA

(BOTH SS & HV)

300KVA

BUS

ASSM. B

ANN.

RTD

3A

TH

RTD

Y

Y

BUS TIE

VENTILATING.

INITIAL

HEATING &

480V BUS

CABLE

3/C-350KCMIL

#2FEEDER

CANAL

A

WH

VAR

A

A

CANAL

FEEDER #1

3/C-350KCMIL

CABLE

A

WH

VAR

W

WASAS

4160V BUS

3AG1

DEMAND FEATURE

WHM WITH

STATION SERVICE

V

VS

2400/4160-120V

WH

W

WH

Y

TRIPS ACB-3AG2

ANNUNCIATOR

T

A

150-5/5 (3Y)

3AG2

400/5 (3Y)

4200/120V

400/5A

TO

ABB EXC

PANEL

WT

A

AS

WH VAR W

V

VS

FSS

2400/4160-120V

5C 700G

SEL

SEL

SEL

SEL

SEL

SEL

RELAYS

TO 4.16KV

GB

AS

SEL

WORKS

TO COMP

A

AA

4.16/13.6kV

3000 KVA

TA

3Y

PPTPPT

EXCITER

TRANSF.

SPARE

(3Y)

3TA1

400/5 (3Y)

800/5 (3Y)

587Z

SEL

800/5 (3Y)

400/5 (3Y)

800/5 (3Y) 800/5 (3Y) 800/5 (3Y) 800/5 (3Y) 800/5 (3Y) 800/5 (3Y)

400/5 (3Y)

500/5 (3Y) 500/5 (3Y)

100/5 (3Y)

50/5 (3Y)50/5 (3Y)50/5 (3Y)

800/5 (3Y)

CF1CF2SP CW SS HV

AND RELAYBOARD DEVICE REPLACEMENT.

2. REFER TO DRAWINGS E-204 AND E-205 FOR BENCHBOARD

1. BOLD/RED INDICATE ITEMS TO BE INSTALLED.

RELAYBOARD LAYOUT INSTALLE-205

BENCHBOARD PNELS 4-7 INSTALLE-204

UNKNOWNDC-179-63 REV. 3

TITLEDRAWING NUMBER

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

CERTIFIED FINAL - READY TO ADVERTISE

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

W

X K -2

-R -0

E-601

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

D E

T R

O

IT

M

IC

H

IG

A N

D E

T R

O

IT

D

IS

T R

V S

W

IT

C H

G E

A R

P O

W E

R H

O U

S E

S A

IN

T M

A R

Y S R

IV

E R

S A

IN

T M

A R

Y S F

A L L S C

A N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

S M

P -5 .0

E -6

X X

X .d g n

IN

S

T A

L L

M A

IN

O

N E -L

IN

E D

IA

G R

A M

G P

Y L E

D

D

IN

H

A N

S I

D

E

V A

U G

H N

S T

E V

E N R

M

IL

E S P .E

/0

/1

S M

P -5 -6 -1 -A -2

/5

A

D D

E D N

O T

E A

N D R

E F

E R

E N

C E D

R A

W

IN

G S E -2

E -2

/1

/2

G

A

SC4-v1-RP4

3AV7

3AV8

3AV9

3AV0

3ASNL1/(YEL)

SC4-c1-RP4

64F3A

3APS

3APS31/(BLU)

3ANS/(ORG)

3ANS/5C3A-B4-

3APS31/5C3A-C1C

A3A-u1-PR3A

PART OF

3AG1P/TS3-9

3AG1T/TS3-11

3AG1P/TBR-16

3AG1T/TBR-14

3AG1P/700G3A-A06

3AG1T/700G3A-A05

C W

RP4-fo1-RP2 (2 FIBER PATCH CORD)

SSTT/[RP5]TBR-10

HTT/[RP5]TBR-7

CF1T/[RP5]TBR-13

CF2T/[RP5]TBR-16

SSTT/[RP2]2505U3A-25

HTT/[RP2]2505U3A-28

CF1T/[RP2]2505U3A-31

CF2T/[RP2]2505U3A-34

3AG2T/[RP2]2505U3A-37 3AG2T/[RP3]TS3-18

RP4-u1-RP6 (EIA-232 TO RTAC)

3AZ1/TS4-17

3AZP/TS4-19

TRBL/TS2-17

3AGFSP/TS2-13

3AGFSN/TS2-15

TRBL/TS2-19

TRBL/700G3A-D01

TRBL/700G3A-D02

TRBL/(TO SCADA)

TRBL/(TO SCADA)

3AGFSP/TBR-31

3AGFSN/TBR-32

3APS/TS3-1

3ANS/TS3-3

3A20/TS3-5

3APS/TS3-1

3AJ31/TS1-11 3AK31/TS2-11

5C3AST/TS4-3

3AG1a1/TS4-1

3AJ11/TS1-3

3AJ12/TS1-1

3AJ21/TS1-7

3AJ22/TS1-5

3AJ32/TS1-9

3AK11/TS2-3

3AK12/TS2-1

3AK21/TS2-7

3AK22/TS2-5

3AK32/TS2-9

3AV7/TS1-13

3AV8/TS1-15

3AV9/TS1-17

3APS3/TS3-7 3A21/TS4-7

3ANS/TS3-3

3ASNL1/TS4-9

64F3A/TS4-5

3AV0/TS1-19

GND BUS

GND BUS

3AJ0/TBR-9

3AN0/TBR-5

3AK3/TBR-6

3AK2/TBR-7

3AK1/TBR-8

3AJ3/TBR-10

3AJ2/TBR-11

3AJ1/TBR-12

3APS/TBL-26

3ANS/TBL-27

3A20/TBL-23

3A20/5C3A-B3+

3AG1a1/TBR-17

3AZ1/TBL-28

5C3AST/5C3A-F1C

3APS3/5C3A-C1

3AJ11/700G3A-E01

3AJ12/700G3A-E02

3AJ21/700G3A-E03

3AJ22/700G3A-E04

3AJ31/700G3A-E05

3AJ32/700G3A-E06

3AK11/700G3A-Z01

3AK12/700G3A-Z02

3AK21/700G3A-Z03

3AK22/700G3A-Z04

3AK31/700G3A-Z05

3AK32/700G3A-Z06

3APS/700G3A-D10

3APS/700G3A-A01

3ANS/700G3A-D13

3ANS/700G3A-A02

3A20/700G3A-A03

3APS3/700G3A-A09

3AZP/700G3A-D04

3AZ1/700G3A-D05

3AG1a1/700G3A-D09

5C3AST/700G3A-A10

64F3A/700G3A-A12

3A21/700G3A-D12

3ASNL1/700G3A-D14

3AV8/700G3A-Z10

3AV9/700G3A-Z11

3AV7/700G3A-Z09

3AV0/700G3A-Z12

3AGFSP/700G3A-E11

3AGFSN/700G3A-E12

3A21/TBL-24

CW1a/TS5-3

CW1b/TS5-1

CW2a/TS5-7

CW2b/TS5-5

CW3a/TS5-11

CW3b/TS5-9

3AMP1/TS5-13

3AMP2/TS5-15

3AMP3/TS5-17

3AMP0/TS5-19

3AMP1/751CW-Z09

3AMP2/751CW-Z10

3AMP3/751CW-Z11

3AMP0/751CW-Z12

CW1/TBR-2

CW2/TBR-3

CW3/TBR-4

CW0/TBR-1

3AMP0/TS2-20

3AMP3/TS2-18

3AMP2/TS2-16

3AMP1/TS2-14

CWP/TBR-26

CWN/[RP2]2505U3A-20

CWa/[RP2]2505U3A-19

SZP/751CW-D04

SZP/TS6-19

CWZ1/TS6-17

CWa1/TS6-7

CWN/TS6-3

CWP/TS6-1

CWN/TS6-3

CWT/TS6-5

RP4-u2-RP6 (EIA-232 TO RTAC)

CWT/751CW-A03

CWN/751CW-A02

CWN/751CW-D10

CWP/751CW-A01

CWT/TBR-28

CWN/TBR-27

CW-TRBL/751CW-D01

CW-TRBL/751CW-D02 CW-TRBL/(TO SCADA)

CW-TRBL/(TO SCADA)

CW-TRBL/TS6-13

CW-TRBL/TS6-15

CWZ1/751CW-D05

CWa1/751CW-D09

CW3a/751CW-Z05

CW3b/751CW-Z06

CW2a/751CW-Z03

CW2b/751CW-Z04

CW1a/751CW-Z01

CW1b/751CW-Z02

3APS/5C3A-F1

3AG1P/5C3A-E2

3AG1T/5C3A-E2C

3AG2T/TS11-6

3AZP/5C3A-F2

[RP5]SZP/TBR-22

CWT/TS6-6

CWT/TS8-2

CWT/[RP2]2505U3A-40

NOTE 5

CWZ/TBR-27

R E

L A

Y B

O A

R D P

A N

E L

T O

P

T S

T S

T S

T S

T S

T S

T S

T S

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

CERTIFIED FINAL - READY TO ADVERTISE

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

W

X K -2

-R -0

E-708

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

D E

T R

O

IT

M

IC

H

IG

A N

D E

T R

O

IT

D

IS

T R

V S

W

IT

C H

G E

A R

P O

W E

R H

O U

S E

S A

IN

T M

A R

Y S R

IV

E R

S A

IN

T M

A R

Y S F

A L L S C

A N

N

S I

D

E

V A

U G

H N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

S M

P -5 .0

E -7

X X

X .d g n

IN

S

T A

L L

P A

N E

L

T O

P

R E

L A

Y B

O A

R D W

IR

IN

G D

IA

G R

A M

G P

Y L E

D

D

IN

H

NOTES:

5. RELABEL CABLE.

4. DEVICE LAYOUT IS TO BE AS SHOWN ON DWG. E-201, NOT OFFSET AS SHOWN HERE.

TO SCADA ARE PERFORMED BY CONTRACTOR.

3. SCADA DRAWING TO BE PROVIDED TO CONTRACTOR POST-AWARD. TERMINATIONS

2. CABLE A3A-u1-PR3A IS RELOCATED FROM THE BREAKER FAILURE CABINET.

1. BOLD/RED INDICATES ITEMS TO BE INSTALLED.

S T

E V

E N R

M

IL

E S P .E

/0

/1

S M

P -5 -6 -1 -A -4

/1

A

M E

N D

M E

N T

R E

V

IS

E D N

O T

E

/2

/2

E-101
E-205
E-601
E-708