This document is an attachment to a Request for Proposal (RFP) for a Multiple Award Construction Contract (MACC) Indefinite Delivery/Indefinite Quantity (IDIQ) contract for general construction requirements at Moody Air Force Base and other locations in Georgia and Florida. The estimated total MACC IDIQ value shall not exceed $150,000,000, with a single five-year ordering period and two one-year option periods. Individual task orders are estimated to range from $2,000 to $7,000,000 and may be subject to statutory cost limitations. This is a competitive set-aside for 8(a), HUBZone, and Small Businesses, with the intent to award nine contracts - three each in the 8(a), HUBZone, and Small Business categories. Offerors must submit the required documentation and complete the Representations and Certifications in Section K, as well as be registered and active in the System for Award Management.
View the file
Other files for this federal contract opportunity
Show all 50
Multiple Award Construction Contract (MACC), Moody AFB has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Moody Air Force Base
Architecture / Engineering Design Guide
Published: July 2016
RFP FA483024R0007
Attachment 1c
INTRODUCTION
Moody’s’ Impact
The local economy benefits from Moody AFB expenditures for salaries, contracts, construction, retirement pay, tuition aid to schools, health insurance payments, and off-installation accommodations for travelers. Moody AFB employed 6,066 military, civilian, and other personnel in fiscal year 2010, with an annual payroll of approximately $300 million. Through service and construction contracts, including primary and secondary employment and payrolls, it is estimated that the total economic impact of Moody AFB on the city of Valdosta and the local area amounts to approximately $448 million annually.
The Guide
This guide contains design checklists to be used in developing functional, aesthetically pleasing, reliable, and maintainable facilities and systems constructed by and for the Air Force. The generic guide will help personnel in charge of the planning, designing, constructing, operating, and maintaining Moody Air Force real property.
This contains guidance that applies to all new construction and to major rehabilitation, alterations, and repair of existing facilities and systems. It applies to all facilities constructed on Moody AFB, Grassy Pond recreation area and Avon Park FL installation.
This guide is intended to serve as a convenient guide to be used in the review and checking of plans and specifications for construction projects. This guide should also be utilized in the early planning stages to determine if all Sustainment Repair and Maintenance (SRM) requirements are being considered for the project. Its main usefulness is to identify and highlight the most prevalent omissions and discrepancies in facility designs.
A secondary feature of this guide provides a feedback system from the field on “lessons learned.” A “lesson learned” is any experience of value having applicability in furthering the goals of the SRM facility program. Lessons may depict successes on innovative techniques, or they may depict deficiencies or problems to be avoided in future designs.
This generic guide is not intended to cover every situation; it is a tool to aid the planner, designer, contactor and maintainer to focus on materials, methods, and system components to enhance Reliability and Maintainability throughout the life of each facility.
The submittal of “lessons learned” from the users, craftsmen, technicians, designers, and construction managers is highly encouraged. This provides a means for continual improvement and refinement, thereby increasing the future value and usefulness of the guide. Handwritten forms and freehand sketches are acceptable.
POC’s:
23D Civil Engineer Squadron Base Architect 23CES/CENMP Victor C. Bivins Chief, Design & Construction 23CES/CENM C. Anthony Payton Chief, Engineer 23CES/CEN William S. Bryan
Table of Contents
CHAPTER 1 GENERAL
1.1 Construction Documents
1.1.1 Specifications
1.1.2 Tri-Service Standard
1.1.3 Drawings Requirements
1.1.4 Drawing Format
1.1.5 As Builts
1.2 Exterior Signage
1.2.1 General
1.2.2 Building Identification
1.2.3 Other Identification Signage
1.2.4 Informational Signs
1.2.5 Directional Signs
1.2.6 Street Name Signs
1.2.7 Graphics
1.2.8 Regulatory Signs
CHAPTER 2
ARCHITECTURAL COMPATIBILITY
2.1 Visual Areas
2.1.1 Admin - Community
2.1.2 Site Planning
2.1.3 Building Form
2.1.4 Roofs
2.1.5 Exterior Walls
2.1.6 Trim
2.1.7 Doors and Windows
2.2 Unaccompanied Recreation Area
2.2.1 Site Planning
2.2.2 Building Form
2.2.3 Roof
2.2.4 Exterior Walls
2.2.5 Trim
2.2.6 Doors and Windows
2.3 Flight Line Industrial Area
2.3.1 Site Planning
2.3.2 Building Form
2.3.3 Roofs
2.3.4 Exterior Walls
2.3.5 Trim
2.3.6 Doors and Windows
2.4 Family Housing
2.5 Undeveloped Areas
2.5.1 Grassy Pond
2.5.2 Cabins and Pavilions
2.5.3 Picnic Shelters
2.5.4 Permanent Buildings & Restrooms
CHAPTER 3 CIVIL
3.1 Curb and Gutter, Sidewalk
3.2 Asphalt and Airfield Pavements
3.3 Site Design
3.4 Site Work
3.5 Utilities
3.5.1 Site
3.5.2 Effective Site Planning/Design
3.5.3 Vehicular Circulation
3.6 Parking
3.6.1 Siting
3.6.2 Screening
3.6.3 Services
3.7 Pedestrian Circulation
3.7.1 Paths
3.7.2 Sidewalks
3.7.3 Special Purpose Lighting
3.7.4 Fences and Screens
3.7.4.1 Screening
3.7.4.2 Fences
3.7.5 Site Components
3.7.5.1 Site Furniture
3.7.5.2 Material and Colors
3.7.5.3 Location
3.7.5.4 Maintenance
3.7.5.5 Mailboxes
3.7.6 Infrastructure
3.7.6.1 Color
3.7.6.2 Screening
3.7.6.3 Lighting
3.7.6.4 Fuel / Water Storage Tanks
3.7.6.5 Security
3.7.6.6 Fire Protection
3.7.6.7 Sewer
3.7.6.8 Efficient Use of Utilities
3.8 Regional Design
3.8.1 Existing Conditions
3.8.2 Surface Runoff
3.8.3 Energy Conservation
3.8.4 Street Trees
3.8.5 Planting Design
3.8.6 Parking Lot Landscaping
3.8.7 Visual Screening
3.8.8 Maintenance
3.8.9 Plant Materials
3.8.10 Landscape materials
3.8.11 Courtyard and Entrances
3.9 Structural
3.9.1 Wind Speed Design
3.9.2 Roof Live Load
3.9.3 Wind Rating
3.9.4 Seismic Zone 1
3.9.5 Foundation
3.9.6 Materials
3.9.7 Code Compliance
CHAPTER 4 ARCHITECTURAL
4.1 Interior Signs
4.1.1 General
4.1.2 Information Signs
4.1.3 Regulatory Signs
4.1.4 Directional Signs
4.1.5 Identification Signs
4.2 Architectural
4.2.1 Design Criteria
4.2.2 Architectural Review
4.2.3 Additions
4.3 Force Protection/Anti-Terrorism
4.4 Site Planning
4.4.1 General
4.4.2 Environmental Stewardship
4.4.3 Visually Objectionable Items
4.4.4 Site development Pattern
4.4.5 Future Development
4.5 Building Form
4.6 Roofs
4.6.1 Forms
4.6.2 Roof Material
4.6.3 Slope
4.6.4 Roof Warranties
4.6.5 Clearstories
4.6.6 Gutters and Downspouts
4.6.7 Rooftop Equipment
4.7 Entrances
4.7.1 Visibility
4.7.2 Entry Sequence
4.7.3 Protective Cover
4.8 Fascia and Soffits
4.8.1 Soffits
4.8.2 Fascial and Trim
4.9 Exterior Walls
4.9.1 Materials and Colors)
4.9.2 Materials (by location/area)
4.9.3 Detailing
4.9.4 Wall Construction
4.10 Windows and Doors
4.10.1 Design
4.10.2 Materials
4.11 Finish Hardware
4.12 Medical Buildings
4.13 Outdoor Pavilions and picnic Shelters
3.14 Metal Buildings
4.14.1 Location
4.14.2 Material/Finishes
4.14.3 Site Justification
4.15. Interior Design-General
4.16. Permanent Finishes
4.16.1 Other Permanent Finishes
4.16.2 Coloring
4.17 Non-Permanent Finishes
4.18 Finishes and Treatments
4.18.1 Carpet
4.18.2 Hard Surface Flooring
4.18.3 Laminates and Solid Surfacing
4.18.4 Vinyl or Rubber Base and Carpet Base
4.18.5 Paint
4.18.6 Wainscot and Chair Rail
4.18.7 Doors and Frames
4.18.8 Window Blinds
4.18.9 Ceilings
4.18.10 Systems/Pre-wire Workstations/Modular
Furniture
CHAPTER 5 MECHANICAL
5.1 General
5.2 Controls
5.3 Mechanical Room Documentation
5.4 Water, Gas & Fuel Systems
5.5 Equipment Rooms
5.6 HVAC
5.6.1 Design Criteria
5.6.2 Air Cooled Condensers
5.6.3 Ductwork
5.6.4 Air handlers, Water Heaters, Pumps
5.6.5 Louvers, Dampers, Mixing Boxes
5.6.6 Coils
5.7 Refrigerant Equipment
5.7.1 General Refrigerant Compression
5.7.2 Insulation
5.7.3 HVAC Refrigerant Systems
5.8 Piping
5.8.1 Chilled and Hot Water
5.8.2 Refrigeration Piping
5.8.3 Piping Identification
5.8.4 Installations and Repairs
5.9 Plumbing
5.9.1 PVC/CPVC Piping Systems
5.9.2 Copper Piping
5.9.3 Sterilization
5.9.4 Pressure Testing
5.9.5 Valve Installation
5.9.6 Installing for Servicing and Cleaning
5.9.7 Prefabrication & Sterilizing
5.9.8 Sewage Lift Stations
5.9.9 Water Distribution System
5.9.10 General – Check
5.9.11 Tracer Wire/Warning Tape
CHAPTER 6 FIRE PROTECTION
6.1 Design
6.1.1 Civil Plans
6.1.2 Architectural
6.1.3 Mechanical Plans
6.1.4 Electrical Plans
6.1.5 Fire Suppression Plans
6.1.6 Fire Alarm Plans
6.2 Specifications
6.2.1 Fire Suppression
6.2.2 Foam System
6.2.3 Fire Alarm
6.2.4 Knox Box
6.3 Testing
CHAPTER 7 ELECTRICAL
7.1 Standards
7.1.1 Drawings
7.1.2 Load Levels
7.2 Power System Protection
7.2.1 Motors
7.3 Exterior Power
7.4 Exterior Lighting General
7.4.1 Exterior Lighting Sports
7.5 Lighting Protections System
7.6 System Grounding
7.6.1 Switchboards, Panelboards
7.7 Generators, Transfer Switches
7.8 Interior Power
7.9 Interior Lighting
7.10 Emergency and Exit Lighting
7.11 Fire Detection, Alarms, Mass Notification
System
7.12 Site Lighting
7.12.1 General Design
CHAPTER 8 COMMUNICATIONS
8.1 Guidance for New Buildings
8.1.1 References
8.1.2 Building Entrance Facilities
8.1.3 Communication Equipment Room
8.1.4 Telecommunications Closet
8.1.5 Cabling
8.1.6 Identify Cabling to be Installed
8.1.7 Communication Outlets Identification
8.2 Full Spectrum Threat Response Mass
Notification System (FSTR/MNS)
8.2.1 General
8.2.2 Exist FSTR/MNS Control Stations
8.2.3 Existing Alarm System
8.2.4 Points of Contact
8.3 Lighting Protection
8.3.1 Copper Lighting Protection
8.3.2 Ground Impedance
8.3.3 Roof Mounted Grounding System
CHAPTER 9 ENVIRONMENTAL
9.1 Environmental Management System
(EMS)
9.2 Hazardous Materials
9.2.1 Asbestos and Lead Paint
9.3 Permits
9.4 Off Base Waste Material Disposal
9.4.1 Environmental Standards
9.5 Tree Protections
9.6 Historic Buildings
9.7 Monitoring Well and Plumes
(Restoration)
1.0 GENERAL
Moody Air Force Base, Georgia
The following guidance is provided for the design and construction of new facilities and the remodeling of existing facilities on Moody Air Force Base. All engineers and planners shall use this guidance in the preparation of their design documents and shall provide this information to Architect-Engineering firms that are preparing project designs for the base.
These guidelines are intended to show the minimum acceptable standards.
1.1 Construction Documents
1.1.1. Specifications:
Specifications for each project shall conform to the CSI standard. Designers shall use editing software to manipulate UFC specifications as listed below or use Moody Air Force Base, Specifications Guide.
Specifications shall be based on the Unified Facilities Guide (UFC) specifications. (See web site below.)
http://www.wbdg.org/ccb/browse_org.php?o=70
1.1.2. Tri-Service Standard: Drawings shall
conform to Tri-Service Standards.
1.1.3. Drawing Requirements: The following are
the minimum drawings required for a project
Title sheet, to include:
the title of the project the project number index of drawings Base map vicinity plan Base map, with the project location and the Civil Engineering, the Contract Management, and the Contracting office locations Moody AFB title block with the appropriate information Each specification sheet and/or individual drawing submittal shall be identified by Title. (i.e. “35% Submittal,” “65% Submittal,” etc.)
Existing and proposed Site Plan (except for projects for interior renovations only) Demolition drawings (if necessary) Foundation/footing Plan Existing and final Floor Plan with Code Analysis
Reflected Ceiling Plan - Include HVAC diffusers and returns, the drop in fluorescent light locations, and heat detectors, to ensure proper layout of all disciplines
Roof Plan (if necessary)
Elevations
Wall and Building Sections
Elevation Details, Window and Door Schedules
Plumbing Plan and Riser Diagrams
HVAC Plan and Schedules
Mechanical Schedules and Details - Include all set points, flow rates, control and riser diagrams, electrical voltage ratings, current requirements and equipment schedules.
Lighting Plan and Fixture Schedule
Power Plan and Riser Diagrams - Include Communication Systems
Electrical Schedules and Details
Fire Detection/Protection Plan
1.1.4. Drawing Format
All final drawings shall use the CSI format
All drawings should be on 24"x36" standard size or 30"x42" sheets.
Each sheet will be numbered in sequence and referenced in the legend on the cover sheet.
Drawings will be submitted in electronic format in uncondensed form, .PDF files and .DWG files in AutoCAD 2014. The Base Civil Engineer representative will provide guidance regarding file names.
1.1.5 As Builts
Designer shall require one complete set of Contract Documents to remain on site to be updated daily of any conditions that deviate from the original Contract Documents. Electronic CADD and PDF as Built drawings shall be turned over to the owner as part of the close out documents.
1.2. EXTERIOR SIGNAGE
The UFC 3-120-01, Air Force Sign Standard establishes guidance for all exterior signs used on Moody AFB. Its purpose is to manage the quality, placement, and number of signs on the installation and to ensure attractive, professional, easy to read, RFP FA483024R0007 http://www.wbdg.org/ccb/browse_org.php?o=70 well maintained, and uniform sign standards throughout the installation. Proper use of signs has a major effect on the appearance of our base and will professionally communicate direction and location of those functions and activities that truly warrant identification. This instruction will specify materials, construction, and methods, to ensure signs are easy to maintain and easy to change.
(ACCI 32-1054 and Moody Supplement must also be used for signage.)
1.2.1 General
All exterior signs will be consistent throughout each installation. Do not use moving signs. LED signage can be used if design has been reviewed and approved by the Base Architect.
Location and content of all exterior signs shall be subject to approval of the Base Civil Engineer. The number of signs will be held to a minimum. Site signage must provide clear, consistent, and necessary direction or information. Correctly designed and controlled signs can be a positive aspect of the installation’s overall professional image.
Signs shall be designed in accordance with UFC-3- 120-01. Lettering shall be Helvetica Medium type style, except Helvetica Regular type style shall be used for subordinate information on building and organization identification signs.
Organization names should normally be shortened to the minimum required to describe the function, for example, “Self-Help Store,” not “Civil Engineering Squadron Self-Help Store” or “Moody AFB Self- Help Store.”
Signage for facilities that house the command section of an organization should include the number of the squadron preceding the organization, for example, “3rd Flying Training Squadron.” Only commonly understood abbreviations will be used.
Monument signs are discouraged but may be authorized and must have approval from the Base Architect. (Figure 1-2d)
1-1a Squadron Identification.
Limit signs to function identification and address, and ensure they are easily readable from the street;
avoid miscellaneous emblems, logos, and direct-paint applications.
1.2.2 Building Identification Signs:
Building and street address numbers shall be used to identify all facilities.
Two options for building ID signs are signs attached to the building and stand-alone signs.
Use only one sign per building except for customer service facilities or large buildings where more than one function is present.
Street addresses will be displayed only on the main entry door.
For entryway bronze Helvetica letter above entrance. (Figure 1-2c)
All facilities shall be identified with three dimensional numbers mounted on the corner most visible from the nearest primary road.
The numbers shall be non-ferrous material, dark bronze in color. Height of numbers shall be selected based on viewing distance and building size.
Individual Air Force bronze anodized Helvetica style aluminum letters shall be used for identification signs on facility walls.
The use of freestanding building identification signs shall be allowed only when building-mounted signage is not feasible.
If a freestanding sign is required, it shall be designed in accordance with UFC 3-120-01, Chapter 4 – Exterior Identification Signs, Type B3 with the following modifications:
Signs shall be aluminum post and panel design with 3-inch square posts.
Only use ACC and wing decals when using Type B2 signs with decals.
Finish shall be fluoropolymer (Kynar 500) coating, or equal.
Locate organization identification in upper left corner, and street address in lower left corner.
Building number may be included but shall be distinguishable from the street address.
1-2b Dark bronze dimensional numerals identify facility number
1-2c Entry way designation above entrance
1-2d Base Ops free-standing identification sign
1.2.3 Other Identification Signage
Additional identification signage may be required on important buildings, such as headquarters, or facilities with significant visitor use (Hospital Administration Moody Field Club, etc.). Base Civil Engineering will evaluate each facility individually.
Individual dimensional letters shall be fabricated from dark bronze non-ferrous material, using uppercase Helvetica Medium type style.
Height of the letters shall be selected based on building size and viewing distance (Figures 1-2e & 1-2f).
Organizations wishing to identify their facilities with a group or squadron patch will be permitted to do so with the approval of the 23 WING.
Patches shall be no larger than four feet at the widest point.
Patches shall be constructed on a raised surface and attached to the facility wall and must present a professionally designed appearance.
Wing/Group level organizations may identify their headquarters buildings with monument type signs or building-mounted plastic letters affixed to the structure.
Identify obscure buildings (well houses, sewage lift stations, etc.) with no more than a building number.
Service or commercial activities (Commissary, BX, snack bars, etc.) shall use building mounted signs with individual letter.
Commercial signature brands may use their signature logos and may display only one sign per building.
Water/POL tanks shall be painted simply in earth tone colors.
The AF symbol with “U.S. Air Force” shall be applied.
No other decals, graphics, or lettering such as shields, mottos, or emblems are authorized.
AAFES/DeCA/Commercial signs shall comply with the following:
Format shall be AAFES logo (where applicable) followed by facility name
1-2e Building Mounted Identification Signage
1-2f Building Mounted Identification Signage
Logo and facility name shall be the same height and positioned on one continuous horizontal line wherever possible
Facility name shall be spelled out completely with individual letters
Logo and letters shall be mounted directly to the building fascia or exterior wall adjacent to the facility’s main entrance. The back edge of logo and letters shall be ¼ inch from the face of the wall for fascia.
Logo and letters shall be light or dark bronze anodized aluminum or other non-corrosive material in a light or dark bronze color.
Logo and letters shall be available in even height increments from 2 to 16 inches. Choose appropriate size and color for each facility and location.
The ratio of height to depth of logo and letters shall be approximately 8 to 1.
When night visibility is functionally required, use external flood or spot lights that illuminate both the sign and the adjacent landscape/building instead of using internally lighted signs, which give a commercial impression.
1.2.4 Information and Motivational Signs
Placement and content of these signs shall be reviewed on an individual basis by the Base Civil Engineer, with an emphasis on maintaining a unified image for the base.
1.2.5 Directional Signs
Directional Signs should follow UFC 3-120-01, Chapter 5 – Direction Signs.
Vehicular directional signs shall be designed in accordance with UFC 3-120-01, Type D2 with the following modifications:
Use white reflective letters on brown background with posts.
Signs shall match construction of existing directional signs at Moody (Figure 1-2g) and shall be constructed of aluminum plate with treated wood 4 x 4 posts. Posts and sign back shall be painted dark brown.
Mounting height shall match height of existing directional signs on base.
Signs shall be located to maintain clear sight lines at intersections, parking lot entrances, etc. (Figure 1-2h)
Install directional signs only where frequently needed to guide visitors and new base personnel.
Exception: destinations which might otherwise be difficult to locate.
No more than four entries shall be displayed on each sign.
1.2.6 Street Name Signs
Street name signs shall have a brown background with white letters and brown posts.
Each sign plate will have a height of 6 inches, and length will be dependent upon the number of letters used, with a maximum length of 30 inches.
Street name letters and numbers will be 4-inch upper case.
The bottom of each sign will be mounted no more than seven feet above the ground.
There shall be a street name sign for each street at intersections.
1-2g Directional Sign
1-2h Street sign at intersection
1.2.7 Graphics
To reduce visual clutter, do not use super graphics, poorly designed signs, and outdated information.
Design graphics to function – define entrances, identify building numbers, and conceal clutter.
Use graphics to relate buildings to each other instead of making a building prominent.
Avoid using high-color contrasting bands and stripes on new buildings or painting structural columns and beams.
Limit unique signing to high-visibility locations where highlights are required to support the architectural theme.
Except for painted masonry and metal buildings, identification signage should only be located in adjacent landscaped space at eye level rather than being attached to walls or fascia.
1.2.8 Regulatory Signs
Posts for all regulatory signs shall be galvanized steel.
Exception: Signposts at Grassy Pond Recreational area may be preservative-treated wood (Figure 2-2i).
All posts and sign backs shall have brown finish to match building identification and directional signage.
Traffic regulation signs (Figure 1-2k) shall be designed in accordance with the Manual of Uniform Traffic Control Devices (MUTCD) published by the Federal Highway Administration.
Base warning signs shall comply with UFC 3- 120-01.
Parking regulation signage shall comply with UFC 3-120-01. Where post-mounted signs are used, posts shall be located to avoid vehicle damage. Handicapped accessible parking spaces shall be identified with a post mounted international symbol of accessibility in compliance with the Architectural Barriers Act.
Reduce the number of parking signs by strictly limiting reserved parking, including temporary reserved parking.
Reserved parking signs shall comply with AFI 31- 204 Moody Sup 1, including paragraph 4.8.2.1 and 4.8.3.4.
Work area and personnel safety regulation signs shall comply with OSHA requirements and applicable Air Force regulations.
Condense and consolidate information to minimize the number of signs.
2-2i Sign posted at Grassy Pond
2-2j Parking sign at Grassy Pond
2-2k Examples of Regulatory signs
2.1 Visual Areas
The Moody Architectural/Engineering Design Guide organizes the physical environment of the base into six visual areas. There are three zones within the main cantonment area of the base: Admin/Community, Unaccompanied Housing, and the Flight Line/Mission Area.
The Family Housing zone is separated from the rest of the base by Bemiss Road. The Open Space zone includes undeveloped land on the east side of the base. Grassy Pond is a recreational area located 27 miles southwest of the base.
Each area is defined by land use and the proposed palette of building materials.
Design recommendations for each area are coordinated to allow facilities to harmonize with the immediate surroundings, as well as support the overall design goals for the base.
1-1 Visual Zone Map
2.1.1 Admin-Community Area
The Admin-Community Area is the core of the cantonment area. Facilities in this zone include headquarters buildings, community center, shopping, recreation, medical and worship facilities. Located near the north gate, it is a public-oriented area and the first image of the base for most visitors
A variety of materials and colors exist on the buildings in this zone. There are different colors of wood siding, some stucco buildings or stucco used as accent with other materials, and approximately six different colors of brick.
Most buildings have sloped roofs with either dark bronze metal roofing or asphalt shingles. An effort has been made to renovate many of the flat roofs with sloped roofs, but a few flat roofs remain.
2.1.1 Administrative-Community Visual Area
The medical buildings create a small campus within the Admin-Community area. These buildings stand out as a group from the surrounding structures due to the use of burnt orange/tan brick, wide stucco fascia’s and similar precast concrete accents.
Because there is such a variety of materials and colors existing within this zone it is necessary to have guidelines that will create overall visual unity rather than small-scale compatibility between adjacent buildings.
To establish a unified image for the area, future facilities will be designed with sloped roofs, dark bronze metal roofing, and brick shall match adjacent structures and shall be approved by the Base Architect during design.
2.1.2 Site Planning
Focus on pedestrian circulation. Provide safe, convenient paths linking administrative areas with popular destinations.
Site new facilities in accordance with the Moody AFB General Plan.
2.1.3 Building Form
Maximum height for all buildings is two stories unless a variance is requested.
Building entrances should be easily visible from the street and parking areas.
Arrange building forms to create easy pedestrian flow from adjacent structures.
2.1.4 Roofs
Dark bronze standing seam metal roofs with minimum 3:12 pitch.
2.1.5 Exterior Walls
Split faced CMU, scored CMU and brick with off-white mortar. All color shall be approved by the Base Architect during design.
Brick detailing such as soldier courses, reveals and special brick shapes are encouraged.
2.1.6 Trim
Metal fascia and gutters shall match metal roof color.
Downspouts typically shall match color of adjacent wall surface or roof color.
2.1.7 Doors and Windows
Aluminum operable windows shall be double insulated, blast resistant and anodized dark bronze.
Primary entrance shall be storefront, blast resistant and shall be dark bronze anodized.
Secondary doors shall be hollow metal; color shall match adjacent wall surface.
2.2 Unaccompanied-Recreation Areas
There are two Unaccompanied-Recreation areas on base that are separated by the Admin-Community zone. The North Unaccompanied Housing area is defined by Coney Street, Burrell Street, and Robinson Road. The South Unaccompanied Housing area is defined by Robbins Road, Davis Street, George Street, and Schrader Street.
Facilities in these areas include Airman Living Quarters, Visiting Officer’s Quarters, Visiting Enlisted Quarters, Fitness Center, recreation fields, Dining Hall, and Bowling Center.
2.2a. Unaccompanied-Recreation Visual Area
Most buildings in this visual area are constructed of red brick with dark bronze metal roofs. Some of the dormitories have concrete exterior stairs with a beige stucco finish. A few buildings such as the Housing Office and Linen Exchange building are brick that has a range of colors from cream to dark brown and large beige stucco fascia’s. One building in the North Unaccompanied Housing area is beige brick with a low sloping asphalt shingle roof.
2.2.1 Site Planning
Focus on pedestrian circulation. Provide safe, convenient paths linking living areas with popular destinations (Figure 2.2.2c).
Site new facilities in accordance with the Moody AFB General Plan.
2.2.2 Building Form
Maximum height for all buildings except dormitories is two stories. Dormitories may be three stories (Figure 2.2.2b).
Building entrances should be easily visible from the street and parking areas.
Arrange building forms to create pedestrian spaces such as arcades and courtyards.
Walkways shall be provided to allow appropriate pedestrian traffic to adjacent facilities.
2.2.3 Roofs
Dark bronze standing seam metal roofs with minimum 3:12 pitch (Figure 2.2.2d).
2.2.4 Exterior Walls
Red brick with off-white mortar. Brick color shall match the dormitory at 7251 Woolsey Street (Figure 1.2.2a).
Brick detailing such as soldier courses, reveals and special brick shapes is encouraged.
2.2.5 Trim
Metal fascia and gutters typically will match metal roof color.
Downspouts shall match color of adjacent wall surface or roof color.
2.2.6 Doors and Windows
Aluminum windows and storefront shall be dark bronze anodized.
Secondary doors shall be hollow metal; color shall match adjacent wall surface.
2.2b Dormitory, Berger Street
2.2c Convenient, well-lit paths encourage pedestrian circulation.
2.2d Red brick and dark bronze metal roof on the Library/Education Center
2.3 Flight Line-Industrial Area
The Flight Line-Industrial visual area comprises the largest developed area on base. It consists of facilities adjacent to the runways and aprons, including Knights Way and Werewolf Run. Facilities in this zone range from relatively small storage, training, and operations buildings, to large warehouses and hangars. The Weapons Storage Area, southeast of the main runways, is also included in this visual area.
A variety of building materials exist in the area. Materials on the buildings near the southern end of the flight line are a mixture of metal panels, exposed aggregate concrete panels, concrete masonry units, and tilt up precast panels.
Some older buildings use high-maintenance wood siding as an exterior finish.
2.3a Flight Line-Industrial Visual Area
The buildings in the Weapons Storage Area are metal storage buildings and bermed facilities.
The C-130 complex, located west of the runways, and the 71st Air Control Squadron, sited east of the airfield, use a similar palette of materials but are distinctive in their detailing. Beige split-face concrete masonry is the dominant wall material, with light brown ribbed concrete masonry units used as accents. The buildings in the C-130 area use beige metal wall panels above the masonry base.
Dark bronze metal roofing is the standard for all the buildings.
2.3.1 Site Planning
Site buildings in functional groups.
Use building forms, landscaping, and masonry enclosures to screen outdoor storage/equipment areas from primary streets.
Eliminate on-street parking where possible.
Avoid locating parking between the building and the primary street.
2.3.2 Building Form
Use simple, functional forms for industrial /operational buildings.
Except on completely utilitarian structures, building entrances should be easily identifiable from the street and from parking areas.
On more people-oriented facilities, arrange building forms to create pedestrian spaces.
2.3.3 Roofs
Dark bronze standing seam metal roofs with minimum 3:12 pitch. Lesser pitch may be used on large buildings with approval of the Base Architect.
For new roofs or major roof replacement projects, meet or exceed the following Solar Reflectance Index (SRI) for a minimum of 75% of the roof surface: SRI > 78 for low slope roofs (< 2: 12); SRI > 29 for high slope roofs (> 2:
12). (Ref: Cool Roof Rating Council; and LEED for New Construction v.2.2, SS Credit 7.2) Comply with published ACC and base architectural policies regarding roofing.
2.3.4 Exterior Walls
Predominant wall material shall be split-face concrete masonry units. Color shall match “Moody Tan” by Scruggs Concrete Co. (Figures 2.3b, 2.3c).
Other concrete masonry textures may be used as accents.
Color shall match “Brown” by Scruggs Concrete Co.
(Figures 2.3b, 2.3c).
Pre-finished metal wall panels may be used on hangars and large industrial buildings with approval of the Base Architect. Metal buildings shall have a split face concrete masonry base with the height proportional to the building size, but not less than four feet high. Color of metal panels shall match adjacent buildings as approved by Base Architect (Figures 2.3a, 2.3b, 2.2.3c).
2.3b Rescue Squadron Building 663
2.3c Wash Rack in C-130 Building 642
2.3.5 Trim
Metal fascia and gutters shall match metal roof color.
Downspouts shall match color of adjacent wall surface or color of metal roofing (Figure 2.3d).
2.3.6 Doors and Windows
Aluminum windows and storefront shall be dark bronze anodized (Figure 2.3a).
Secondary doors shall be hollow metal, color shall match adjacent wall surface.
2.3d Buildings in the C-130 Complex use concrete masonry base with beige metal wall panels above, and dark bronze metal roofing.
2.3e Building 730. Downspout color matches roof color.
2.4.4 Family Housing
2.4a
The Family Housing Visual Area is separated from the main base by State Highway 125 (Bemiss Road). Facilities include family housing, the golf course, recreational facilities, and ball fields. The absence of operations and administrative functions in the Family Housing area helps create the character of a private-sector suburban neighborhood.
Moody Family Housing is privatized. All non-housing facilities built within this zone must follow the guidelines for construction within the Admin/Community zone.
1.2.4a Family Housing Visual Area
The majority of the housing units are one story brick with gently sloping asphalt shingle roofs, a small section of houses is two story with brick base and vinyl siding.
Six different colors of brick, from light gray to red, create variety within the area. Light colored vinyl siding is used on many units as a secondary wall material. Many homes have carports with wood columns and pitched asphalt shingle roofs. The recreational facilities are beige concrete masonry with brown concrete masonry accents and a dark bronze metal roof.
Both areas are managed by an independent contractor.
2.5 Undeveloped Visual Area
The Undeveloped visual area includes more than 5,500 acres of land located east of the runways, and a small land area south of the runways. With the exception of the Grand Bay Weapons Range, which occupies 450 acres, the land is managed as a fish and wildlife conservation area by the Georgia Department of Natural Resources. A large portion is wetlands, the largest inland waterfowl resting area in south-central Georgia. This land is primarily used for outdoor recreation such as hunting, fishing and camping.
2.2.5a Undeveloped Visual Area
Significant future development in the Undeveloped Area is not anticipated.
Industrial or mission-related buildings constructed within the zone should conform to the standards established for the Flight Line- Industrial Area (refer to Section 1.9.0).
Areas indicated in white below, represent Undeveloped Visual Areas.
2.5.1 Grassy Pond
Owned by Moody AFB, Grassy Pond Recreational Area is located approximately 27 miles southwest of the base. Its 489 acres of land is available for outdoor recreational activities such as camping, canoeing, mountain biking, and hiking. There are two lakes; Grassy Pond and Lot Pond, which cover approximately 217 and 44 acres, respectively (Figure 2.5b).
The overall image of the area is that of a well-maintained state park. Existing rental cabins and pavilions are constructed of wood frame with painted plywood siding, wood trim, and asphalt shingle roofs (Figures 2.5b, 2.5c).
Modular buildings with vinyl siding are also used as cabins. The concessions/administration building is a prefabricated metal building with a large adjacent wood deck overlooking Grassy Pond.
Existing picnic shelters are log frame construction with asphalt shingle roofing (Figure 2.5c). Exterior walls of recently constructed restroom facilities are beige split-face concrete masonry with dark bronze metal roofing and trim. Asphalt paving is located in high traffic areas, but most vehicular circulation is on gravel or crushed limestone roads.
2.2.5b Main lodge and play area at Grassy Pond
2.5c Lakeside screened pavilion
2.5d Entrance road to Grassy Pond recreation area
Facilities design and site planning shall enhance the “state park” image of the area. Site buildings to take advantage of views and prevailing breezes. Minimize impact on the natural environment.
2.5.2 Cabins and Pavilions
For economy and compatibility with the existing rustic context (Figure 2.5e), rental cabins and outdoor pavilions shall be constructed using wood siding, wood trim, and asphalt shingle & metal roofing. Base Civil Engineering design guidance for cabins requires use of simple hip roof forms, with screened porches, double-hung windows, and board and batten wood siding (Figure 2.5f).
2.5e Rental cabins
2.5f Rental Cabin – Prototypical Elevation
2.5.3 Picnic Shelters
New shelters shall be similar to existing log frame structures with brown asphalt shingle roofs (Figure 2.5g). It is recommended that exposed wood be finished/treated to allow wood to appear as if unfinished. Stain is preferable to paint. If painting is required, exposed wood should be painted dark brown to blend with the natural landscape.
2.5.4 Permanent Buildings and
Restrooms
Future concessions administrative buildings and public restroom facilities will be constructed of split-face concrete masonry and dark brown metal roofing to match the existing restrooms in the park.
Use simple hip or gabled roof forms with 3:12 pitch. Metal fascia and gutters shall match roof color; downspouts shall match adjacent wall color (Figure 2.5h).
2.5g Restroom facility
3.0 CIVIL
3.1 Curb and Gutter, and Sidewalk:
Unless directed otherwise by Base Civil Engineering, specify valley gutter (rollover curb) where site conditions do not require a vertical curb face for drainage capacity.
Where adding to or patching existing curb, match existing curb type.
Standard sidewalk design, provide 5’ wide and 4” thick sidewalks, unless directed otherwise by base Civil Engineering.
All valleys, gutters, and sidewalks shall be Class “A” Portland cement concrete and meet Georgia DOT specifications, construction standards, and details.
The Portland cement concrete valleys, gutters, and sidewalks shall meet a minimum of 3000 psf compressive strength at 28 days.
3.2 Asphalt and Airfield Pavements:
The asphalt for roads, streets, and parking lots shall meet Georgia DOT specifications.
For primary streets that are asphalt use 6” granite aggregate base (Group 2 under GA DOT) and 4” pavement.
For secondary streets use 6” aggregate base (Group 2 under GA DOT) and 2” pavement.
For parking lots use 6” aggregate base and 2” pavement.
Do not use dolomite limestone for concrete aggregate. Aggregate must be Group 2, GA DOT.
To allow for drainage, provide a minimum of 1% slope on asphalt pavement, and 0.5% slope on concrete pavement.
Pavement markings shall follow Military Traffic Management Command (MTMC).
Standard street design, provide 12’ wide lanes.
Provide 90 degree parking and 9’-6” x 18’-6” parking spaces. Aisle widths shall be 25’.
When this is not feasible and angled parking must be used, the angle of the parking shall be 60 degrees with an aisle width of 16’.
Airfield pavements shall be designed according to Unified Facilities Criteria (UFC).
3.3 Site Design
The areas in-between and around buildings need to be as well thought out as buildings. Well-designed outdoor spaces help create friendly, inviting, walk able communities. Site selection and design are important to achieve compatibility with the Base General Plan. The following guidelines will help contribute to this compatibility.
Coordinate with Base Civil Engineering personnel during the initial programming phase of the project for force protection/anti-terrorism requirements.
Moody AFB will be developed in a manner which maximizes mission accomplishment, optimizes use of existing facilities, and provides the most efficient, safe, pleasant, and professional surroundings possible.
3.4 Site Work
Sidewalks that can be driven on should be of sufficient thickness to support vehicle loads.
Pole type light fixtures in parking lots should be placed on concrete pedestals to avoid damage to the poles by vehicles.
Sodding is to be used for established turf areas.
Ensure that all areas drain satisfactorily away from the facility.
Refuse collection pads with privacy screen are to be sized and provided with necessary access to accommodate the large pickup vehicles and are to be located the correct distance away from the facility.
On gutter less roof lines provide a gravel or crushed stone splash area in the design to prevent mud splatter on lower outside walls.
Site design shall conform to the requirements of
ABA.
3-4a Siting of trees to provide adequate shading of buildings and other areas
3.5 UTILITY
Use concrete storm drainage pipes in lieu of metal or polyethylene/plastic pipe.
Utilities shall be bored under streets.
Cut sidewalks at expansion joints.
The fill material shall be free from rock, roots, silts, and other debris.
Restore areas disturbed during construction with centipede grass block sod.
Seed with centipede grass for large areas (>0.5 acres)
3.5.1 Site
Locate buildings in supporting common functions such as civil engineering, administrative, or flying functions in complexes in order to share a common infrastructure of roads, parking, utilities, and security.
Where possible, integrate new buildings into existing groupings.
After positive drainage away from buildings has been developed, use existing or natural grades and contours to avoid excessive cut and fill operations.
Sites shall allow minimum setbacks from other structures such as buildings, roads, and parking.
Keep setbacks consistent with buildings and other structures in the area.
Refer to DOD Minimum Antiterrorism Standards for building setback requirements.
3.5.2 Effective Site Planning and Design
Site buildings in accordance with appropriate laws and directives, etc.
Design new buildings to be compatible w/ local architectural standards, etc.
Ensure energy conservation is considered in design.
Provide functional layouts that are logical and satisfy users’ needs as well as layouts that are able to accommodate other future users. Anticipate and plan for expansion.
3.5.3 Vehicular Circulation
When existing traffic patterns are changed by new construction proposals, provide adequate traffic alternatives to coincide with the construction for the new project. Locate buildings so that workers can walk between buildings in a functional group. Only encourage driving when walking cannot be accommodated.
Develop streetscapes by providing street lighting, sidewalks, and street trees (Figure 3-3b). Provide curb and gutter at all new pavement. Separate vehicular and pedestrian circulation.
Locate utilities underground where feasible
Provide maintenance vehicle access to building mechanical rooms where feasible. Pavement or reinforced sidewalks are acceptable for vehicle access.
Ensure handicapped access is provided at intersections and crosswalks.
Site design shall comply with USAF Installation Force Protection guidelines. Coordinate requirements with Base Civil Engineering representative prior to the start of a project.
Ensure handicapped access is provided at intersections, crosswalks and wherever ABA require them to be.
3-5b Street lighting and sidewalks improve safety and appearance.
3.6 PARKING
Design parking areas to provide a safe, functional layout and reduce the visual impact of parked cars
Use drop-off areas at high-use facilities to decrease close-in parking as required by ATFP.
Curb all parking lots and avoid wheel stops. Use raised parking islands to break up parking areas.
Use size, location, and screening to prevent parking from becoming a dominant feature.
Use consistent angles and stall sizes in all parking areas.
Subdivide large parking areas into lots of 40-50 cars or less, where feasible.
Small parking areas shall be designed to meet ATFP requirements and reduce the negative visual impact and allow opportunity for additional landscaping.
3.6.1 Siting
Site parking areas around the perimeter of building groups. Plan the site to locate parking behind buildings when possible.
Avoid locating parking between a building and the main viewing street (Figure 3-6a).
Avoid letting parking occupy pedestrian spaces between buildings in a group.
Provide safe pedestrian paths from parking to building entrances.
Provide handicap accessible parking spaces and accessible routes to the building in conformance with
ABA. Motorcycle parking shall be provided for each structure, and shall be concrete not asphalt.
Parking areas should be set back from streets.
Setbacks a minimum of 20 feet wide will allow adequate space to incorporate planting for effective screening.
Parking shall be as required by the UFC or as follows.
Occupied structures shall have a minimum 25 meters to parking, unoccupied structures shall have a minimum 12 meters to parking.
Eliminate on-street parking where possible. Do not locate parking directly in front of buildings or entrances. Locate parking behind buildings.
3-6a Sidewalks leading from parking lot to the main building across the street.
3-6b Parking lot connected by crosswalks and sidewalks to the building across the street.
3-6c Landscaping screens parking lot from adjacent roadway.
3.6.2 Screening
Use buildings, natural topography and landscaping to screen parking from the primary street (Figures 3- 6c).
When developing parking areas, try to save as many desirable existing trees and shrubs as possible.
Consider building shape and relationship to other buildings to provide as much screening as possible.
3.6.3 Services
Separate service/ dumpster locations from pedestrian circulation. Ensure turnaround space for fire trucks and service vehicles.
Access to dumpsters must be adequate to accommodate a 40’ long dump truck with 60’ turn radius. Truck cannot back into traffic flow.
Locate dumpsters to remote/hidden areas on site.
3.7 PEDESTRIAN CIRCULATION
3.7.1 Paths
Provide safe, convenient paths to encourage bicycle and pedestrian circulation.
Use concrete walkways at least 60 inches wide to link facilities and promote pedestrian use.
Design continuous paths linking buildings, courtyards, parks, and other activity nodes.
Provide walkways between buildings with users of organizations that work together.
Provide paths with the roadway or create separate jogging trails. Separate vehicular and pedestrian circulation.
If used exterior water fountains shall be freeze proof.
Locate seating areas or stopping points along paths.
Illuminate walkways used heavily at night.
Provide walkways on at least one side of every street and between all facilities.
3.7.2 Sidewalks
Provide sidewalks on at least one side of every street and between all facilities.
Set sidewalks back an appropriate distance from the curb edge to allow for landscaping and maintenance.
Promote security: Configure paths and design landscaping to permit surveillance of pedestrian circulation routes (Figure 3-7a).
Provide low-maintenance, vandal resistant seating and water fountains at intervals along paths.
Landscape walkways, and provide shade trees along paths.
3-7a Well lighted paths encourage pedestrian circulation.
3-7b Covered walkway connecting the new gymnasium building to the old gym.
3.7.3 Special Purpose and Other Lighting
Use architectural lighting of landmark buildings to aid way-finding and accentuate important structures.
Coordinate proposed lighting scheme with Base Civil Engineering.
Use of lighted bollards along high-use walkways and for low level path lighting is suggested.
Bollard (cylindrical top-lit post) fixtures should be dark bronze metal finish (Figure 3-7a), extruded aluminum, 36” high, 7” diameter, 70W LED lamp, individually fused, and photo control.
Solar lighting shall be considered in remote areas only.
Paths should be well lit for safety and to promote pedestrian circulation 3.7a.
3.7a Bollard lighting fixtures in Unaccompanied Housing Area.
3.7.4 FENCES AND SCREENS
3.7.4.1 Screening
Provide screening around mechanical equipment, storage areas, trash dumpsters and other visually objectionable items. Limit use of screen walls in accordance with UFC 4-010-01 the USAF Installation Force Protection Guide.
Dumpster bollards shall not be placed more than 6’ apart.
Mechanical equipment enclosures shall match adjacent building materials (Figures 3.7c); materials other than those that match the adjacent building shall be approved by the Base Architect. Masonry walls are preferred.
The use of open panel block is allowed when enclosing electrical substations, transformers, or switches for proper heat dissipation.
Equipment screens shall allow required clearance for equipment maintenance, removal, and airflow.
Provide vehicle access to mechanical equipment areas where necessary. Pavement or reinforced sidewalks are acceptable for vehicle access.
Enclosure walls shall be 6’ high, unless the enclosed object is greater than 6’ tall, in which case the enclosure walls should be 6” higher than the tallest object being concealed. Enclosure shall be large enough for 2 (two) dumpsters.
Provide concrete slab and 6” diameter concrete filled pipe bollards to prevent damage to walls (Figure 3- 7d).
Dumpsters shall be screened with 3-sided masonry enclosures (Figure 3-7d), vinyl or metal panel fence. Slope dumpster pad to provide positive drainage.
Provide gates for trash enclosures or where accessibility or serviceability is an issue of concern/function.
3.7.4.2 Fences
Use masonry walls or metal panel privacy fences to screen storage areas. Metal fence shall have factory finish with 20-year warranty.
3-7c Screen matches adjacent building in Admin/Community Area.
3.7d Dumpster enclosure, plan view.
3-7e Dumpster enclosure matches masonry of nearby buildings.
Color shall be Brown, Fed. Std. 595b #30051 with semi-gloss finish.
Use of chain link fencing shall be limited to high security functions. Prior approval of Base Architect is required. Fabric or privacy slats shall not be used in chain link fencing.
3.7.5 Site components
Develop a coordinated base wide approach to site components. This includes all site furniture, mailboxes, drinking fountains, flagpoles, picnic shelters, newspaper vending machines, planters, smoking receptacles, and other equipment in design plans.
Encourage attention to detail concerning each of these site components. Work to reduce visual clutter, unnecessary signs, receptacles, etc. Include all applicable standards including force protection/anti-terrorism.
The design of site should respond to the local climate and cultural influences.
Site components shall be accessible to the handicapped and comply with the requirements of
ABA.
Flag poles should be located in accordance with AFR 900-3.
Morale flags are not allowed in accordance with AFI 84-105.
3.7.5.1 Site Furniture
Site furniture is defined as furniture or other accessories provided in outdoor areas for the comfort or convenience of personnel.
Site furniture includes benches, picnic tables, litter receptacles, ash cans, and bicycle racks.
Furniture shall be comfortable,…