Part_8_-_Toe_Seep_Modifications_Plans_and_Specs_4-7-2015.pdf
PDF 2 MB Posted
- Solicitation number
- DQ1 FAAA FEEA2015000000000001 4
- Issued by
- Rio Grande County, Denver City, Colorado
About this file
This file is a technical specifications document for XBT GT and XBT GK human-machine interface (HMI) touch panel units, not a state or local contract opportunity document. The document provides detailed part identification, functions, and technical specifications for multiple series of industrial control panels manufactured by Schneider Electric, including the XBT GT1100, GT1005, GT2000, GT4000, GT5000, GT6000, and GT7000 series, as well as the XBT GK2000 series. Each series features variations in display capabilities, communication interfaces (including serial, Ethernet, and USB connectivity), power specifications, and expansion capabilities. The document includes comprehensive diagrams and descriptions of component locations and functions for front, rear, left, and right panel orientations across all model variations, with detailed explanations of status LEDs, terminal blocks, CF card slots, and interface ports specific to each series.
The specifications document contains no pricing information, contract terms, set-asides, award dates, response deadlines, site visits, or bidding procedures. This appears to be a technical reference manual or product specification sheet included as supporting documentation rather than the primary contract solicitation materials. The document does not reference any procurement requirements, funding sources, or contract award information relevant to a state or local government contracting opportunity.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specifications
35010372 9/2007 61
Input Circuit
Output Circuit
24 VDC
5.4 k
1.2 k
24 VDC
10 k
470 pF
Load+
62 35010372 9/2007
3.4 Part Numbers and Functions
At a Glance
Overview This section presents the Part Number and Functions of XBT GT and XBT GK units.
What's in this Section?
This section contains the following topics:
Topic Page Parts Identification and Functions 63
Terminal Configuration Switches 90
35010372 9/2007 63
Parts Identification and Functions
XBT GT1100 and XBT GT1130 Side XBT GT1100 XBT GT1130
Front
Rear
Bottom
A,B
G
C
A,B
G
C
F F
H E D DEHI
64 35010372 9/2007
Part Description A Display: displays user created screens and remote equipment variables.
B Touch panel: performs screen change operations and sends data to the host
(PLC).
C Status LED
D Power input Terminal block: connects the XBT GT power cable’s input and ground wires to the XBT GT.
E Serial I/F (host I/F 8 pin RJ45): connects a RS-232C or RS485 (serial) cable (from the host/PLC) to the XBT GT (Y port).
F Tool port connector: connects the Data Transfer Cable to the XBT GT.
G Function switches (R1 to R6): used for function keys.
H RS485 Line Polarization Selector Switch.
I Ethernet Interface (except for XBT GT1100): permits to connect the XBT GT unit (X port) to PLC from a Ethernet cable.
35010372 9/2007 65
XBT GT1005
Series Side XBT GT1105 XBT GT1135/1335
Front
Rear
Bottom
A,BC A,BC
F F
DE G DEH G
66 35010372 9/2007
Part Description A Display: displays user created screens and remote equipment variables.
B Touch panel: performs screen change operations and sends data to the host
(PLC).
C Status LED
D Power input Terminal block: connects the XBT GT power cable’s input and ground wires to the XBT GT.
E Serial I/F (host I/F 8 pin RJ45): connects a RS-232C or RS485 (serial) cable (from the host/PLC) to the XBT GT (Y port).
F USB interface (USB1.1): connects a data transfer cable or peripherals or PLC USB terminal port to XBT GT.
G RS485 Line Polarization Selector Switch.
H Ethernet interface (LAN) (10Base-T/100Base-TX): RJ-45 connector is used, and the LED turns ON or OFF to indicate the current status.
Green ON: data transmission available.
Green OFF: no connection or subsequent transmission failure.
Yellow ON: data transmission is occurring.
Yellow OFF: no data transmission.
35010372 9/2007 67
XBT GT2000
Series Side XBT GT2000 series Part Identification
Front
Rear
Left and Right
A,B
C
D
E
H
I
G J
F
K
Left Right
68 35010372 9/2007
CF Card Cover Open
Part Description A Display: displays user created screens and remote equipment variables.
B Touch panel: performs screen change operations and sends data to the host
(PLC).
C Status LED:
Green (steady): normal operation (power is ON) or OFFLINE operation.
Orange (steady): backlight burnout is detected.
Orange (blinking): during software startup.
Red (steady): when power is turned ON.
Not lit: power is OFF.
D Expansion unit interface: connects expansion units with communication features.
E CF card access lamp (except XBT GT2110):
Green ON: the CF card is inserted and the cover is closed, or the CF card is being accessed.
Green OFF: the CF card is not inserted or is not being accessed.
F Ethernet interface (10Base-T/100Base-TX) (except XBT GT2110/2120): RJ-45 connector is used, and the LED turns ON or OFF to indicate the current status.
Green ON: data transmission available.
Green OFF: no connection or subsequent transmission failure.
Yellow ON: data transmission is occurring.
Yellow OFF: no data transmission.
G Power input terminal block: connects the XBT GT power cable’s input and ground wires to the XBT GT.
H USB interface (USB1.1): connects a data transfer cable or peripherals or PLC USB terminal port to XBT GT.
I Serial interface COM1: connects a RS-232C or RS422-485 (serial) cable (from the host/PLC) to the XBT GT (COM1 port).
J Serial interface COM2: connects a RS485 (serial) cable (from the PLC) to the XBT GT (COM2 port).
K RS485 line polarization switch selector.
Side XBT GT2000 series Part Identification
M
L
35010372 9/2007 69
XBT GT4000
Series
L CF card cover: covers the CF card slot. This cover must be closed when accessing the CF card (except XBT GT2110) (see p. 90).
M CF card socket: permits insertion of the CF card.
Part Description
Side XBT GT4000 series Part Identification
Front
Rear
A,B
C
D
E
70 35010372 9/2007
Left and Right
CF Card Cover
Part Description
A Display: displays user created screens and remote equipment variables.
B Touch Panel: performs screen change operations and sends data to the host
(PLC).
C Status LED:
Green (steady): normal operation (power is ON) or OFFLINE operation.
Orange (steady): backlight burnout is detected.
Orange (blinking): during software startup.
Red (steady): when power is turned ON.
Not lit: power is OFF.
D Expansion unit interface: connects expansion units with communication features.
Side XBT GT4000 series Part Identification
H
I
G
JF
K
Left Right
L
M N O
35010372 9/2007 71
E CF card access lamp:
Green ON: the CF Card is inserted and the Cover is closed, or the CF Card is being accessed.
Green OFF: the CF Card is not inserted or is not being accessed.
F Auxiliary input/output/voice output interface (AUX). This interface is used for:
External reset Alarm output Buzzer output Sound output
G Audio input interface (L-IN/MIC): this interface is used to connect a microphone (use mini jack connector of 3.5 mm) (XBT GT4340 only).
H Video input interface: this interface is used to connect a video camera NTSC (59.9 Hz)/PAL (5 0Hz). Use with the RCA convertor 75 ) (XBT GT4340 only).
I Power plug connector: the power cable is connected through this connector.
J Serial interface COM1: connects a RS232C or RS422-485 (serial) cable (from the host/PLC) to the XBT GT (COM1 port).
K Serial interface COM2: connects a RS485 (serial) cable (from the PLC) to the XBT GT (COM2 port).
L RS485 line polarization selector switch.
M Ethernet interface (10Base-T/100Base-TX) (except XBT GT2110/2220): RJ-45 connector is used, and the LED turns ON or OFF to indicate the current status.
Green ON: data transmission available.
Green OFF: no connection or subsequent transmission failure.
Yellow ON: data transmission is occurring.
Yellow OFF: no data transmission.
N USB host interface (USB1.1): connects a data transfer cable or peripherals or PLC USB terminal port to XBT GT.
O CF card cover: covers the CF card slot. This cover must be closed when accessing to the CF card (see p. 90).
Part Description
72 35010372 9/2007
XBT GT5230
Side XBT GT5230 Part Identification Front
Rear
A,B
C
G H
I J
35010372 9/2007 73
Left and Right
CF Card Cover Open
Side XBT GT5230 Part Identification
D
Left Right
E F
ML P Q R
74 35010372 9/2007
XBT GT5330 and 5340 Parts Identification Side XBT GT5330 and 5340 Part Identification
Front
Rear
A,B
C
G H
ML O P
35010372 9/2007 75
Left and Right
CF Card Cover Open
Part Description
A Display: displays user created screens and remote equipment variables.
B Touch panel: performs screen change operations and sends data to the host
PLC.
C Status LED:
Green (steady): normal operation (power is ON) or OFFLINE operation.
Orange (steady): backlight burnout is detected.
Orange (blinking): during software startup.
Red (steady): when power is turned ON Not lit: power is OFF
Side XBT GT5330 and 5340 Part Identification
D
F
E
RightLeft
I N O
76 35010372 9/2007
D Expansion unit interface: connects expansion units with communication features.
E Ethernet interface (LAN) (10Base-T/100Base-TX): RJ-45 connector is used, and the LED turns ON or OFF to indicate the current status.
Green ON: data transmission available.
Green OFF: no connection or subsequent transmission failure.
Yellow ON: data transmission is occurring.
Yellow OFF: no data transmission.
F USB host interface (USB1.1) (x2): connects a data transfer cable, USB-compatible printer, peripherals, or a PLC USB terminal port to the XBT GT. The maximum communication distance is 5 m.
G Expansion unit interface (EXT1): connects expansion units with communication features.
H Expansion unit interface (EXT2): extends a display function
I Auxiliary input/output/voice output interface (AUX): this interface is used for:
External reset Alarm output Buzzer output Sound output
J Expansion memory interface cover
K CF card access lamp:
Green ON: the CF card is inserted and the cover is closed, or the CF card is being accessed.
Green OFF: the CF card is not inserted or is not being accessed.
L Power plug connector: power cable is connected to this connector.
M CF card cover: the CF card I/F and DIP Switches are located in the CF card cover (they are accessible when the card cover is open). This cover must be closed when accessing the CF card (see p. 90.)
N Audio input interface (L-IN/MIC): this interface is used to connect a microphone (use mini jack connector of 3.5 mm) (XBT GT5340 only).
O Video input interface: this interface is used to connect a video camera NTSC (59.9 Hz)/PAL (50 Hz). Use with the RCA convertor 75 ) (XBT GT5340 only).
P Serial interface COM1: connects a RS232C or RS422-485 (serial) cable (from the host PLC) to the XBT GT (COM1 port).
Q Serial interface COM2: connects a RS485 (serial) cable (from the host PLC) to the XBT GT (COM2 port).
R RS485 line polarization selector switch
35010372 9/2007 77
XBT GT6000
Series Side XBT GT6000 series Part Identification
Front
Rear
Left and Right
A,B
C
G H
K
JI
78 35010372 9/2007
CF Card Cover Open
Part Description
A Display: displays user created screens and remote equipment variables.
B Touch panel: performs screen change operations and sends data to the host
PLC.
C Status LED:
Green (steady): normal operation (power is ON) or OFFLINE operation.
Orange (steady): backlight burnout is detected.
Orange (blinking): during software startup.
Red (steady): when power is turned ON Not lit: power is OFF
D Expansion unit interface: connects expansion units with communication features.
E Ethernet interface (LAN) (10Base-T/100Base-TX): RJ-45 connector is used, and the LED turns ON or OFF to indicate the current status.
Green ON: data transmission available.
Green OFF: no connection or subsequent transmission failure.
Yellow ON: data transmission is occurring.
Yellow OFF: no data transmission.
F USB host interface (USB1.1) (x2): connects a data transfer cable, USB-compatible printer, peripherals, or a PLC USB terminal port to the XBT GT. The maximum communication distance is 5 m.
G Expansion unit interface (EXT1): connects expansion units with communication features.
H Expansion unit interface (EXT2): extends a display function
I Auxiliary input/output/voice output interface (AUX): this interface is used for:
External reset Alarm output Buzzer output Sound output
Side XBT GT6000 series Part Identification
N O
35010372 9/2007 79
J Expansion memory interface cover
K CF card access lamp:
Green ON: the CF card is inserted and the cover is closed, or the CF card is being accessed.
Green OFF: the CF card is not inserted or is not being accessed.
L Power plug connector: the power cable is connected through this connector.
M CF card cover: the CF card I/F and DIP switches are located in the CF card cover (they are accessible when the card cover is open). This cover must be closed when accessing the CF card (see p. 90.)
N Audio input interface (L-IN/MIC): this interface is used to connect a microphone (use mini jack connector of 3.5 mm) (XBT GT6340 only).
O Video input interface: this interface is used to connect a video camera NTSC (59.9 Hz)/PAL (50 Hz). Use with the RCA convertor 75 ) (XBT GT6340 only).
P Serial interface COM1: connects a RS232C or RS422-485 (serial) cable (from the host PLC) to the XBT GT (COM1 port).
Q Serial interface COM2: connects a RS485 (serial) cable (from the host PLC) to the XBT GT (COM2 port).
R RS485 line polarization selector switch
80 35010372 9/2007
XBT GT7000
Series Side XBT GT7000 series Part Identification
Front
Rear
A,B
C
G H
K
JI
35010372 9/2007 81
Left and Right
CF Card Cover
Part Description
A Display: displays user created screens and remote equipment variables.
B Touch panel: performs screen change operations and sends data to the host
PLC.
C Status LED:
Green (steady): normal operation (power is ON) or OFFLINE operation.
Orange (steady): backlight burnout is detected.
Orange (blinking): during software startup.
Red (steady): when power is turned ON Not lit: power is OFF
Side XBT GT7000 series Part Identification
D
F
E
RightLeft
N O
82 35010372 9/2007
D Expansion unit interface: connects expansion units with communication features.
E Ethernet interface (LAN) (10Base-T/100Base-TX): RJ-45 connector is used, and the LED turns ON or OFF to indicate the current status.
Green ON: data transmission available.
Green OFF: no connection or subsequent transmission failure.
Yellow ON: data transmission is occurring.
Yellow OFF: no data transmission.
F USB host interface (USB1.1) (x2): connects a data transfer cable, USB-compatible printer, peripherals, or a PLC USB terminal port to the XBT GT. The maximum communication distance is 5 m.
G Expansion unit interface (EXT1): connects expansion units with communication features.
H Expansion unit interface (EXT1): extends a display function
I Auxiliary input/output/voice output interface (AUX): this interface is used for:
External reset Alarm output Buzzer output Sound output
J Expansion memory interface cover
K CF card access lamp:
Green ON: the CF card is inserted and the cover is closed, or the CF card is being accessed.
Green OFF: the CF card is not inserted or is not being accessed.
L Power plug connector: power cable is connected to this connector.
M CF card cover: the CF card I/F and DIP switches are located in the CF card cover (they are accessible when the card cover is open). This cover must be closed when accessing the CF card (see p. 90.)
N Audio input interface (L-IN/MIC): this interface is used to connect a microphone (use mini jack connector of 3.5 mm) (XBT GT7340 only).
O Video input interface: this interface is used to connect a video camera NTSC (59.9 Hz)/PAL (50 Hz). Use with the RCA convertor 75 ) (XBT GT7340 only).
P Serial interface COM1: connects a RS232C or RS422-485 (serial) cable (from the host PLC) to the XBT GT (COM1 port).
Q Serial interface COM2: connects a RS485 (serial) cable (from the host PLC) to the XBT GT (COM2 port).
R RS485 line polarization selector switch.
35010372 9/2007 83
XBT GK2000
Series Side XBT GK2000 series Part Identification
Front
Part Description
A Display: displays user created screens and remote equipment variables.
B Touch panel: performs screen change operations and sends data to the host
PLC
C Status LED:
Green (steady): normal operation (power is ON) or OFFLINE operation.
Orange (steady): backlight burnout is detected.
Orange (blinking): during software startup.
Not lit: power is OFF
D Function keys (R1 to R10, R21 to R24, F1 to F10): used for function keys.
E System keypad: controls various system operations.
F Alphanumeric keypad: enables the user to input characters or numeric values.
G Mouse pointer: the pointer moves the cursor and the buttons activate objects and enable data inputs.
A,B
C
E D
F G
84 35010372 9/2007
Side XBT GK2000 series Part Identification Rear
Left and Right
H I
J
K
L
Left Right
N
O P
M Q
35010372 9/2007 85
CF Card Cover Open
Part Description H Expansion unit interface (EXT1): connects expansion units with communication features.
I Ethernet indicator: the LED turns ON or OFF to indicate the current status.
Green ON: Data transmission available.
Green OFF: No connection or subsequent transmission failure.
Yellow ON: Data transmission is occurring.
Yellow OFF: No data transmission.
J CF card cover: the CF card socket and DIP Switches are located under the CF card cover (they are accessible when the card cover is open). This cover must be closed when accessing the CF card (see p. 90.)
K CF card access lamp:
Green ON: the CF card is inserted and the cover is closed, or the CF card is being accessed.
Green OFF: the CF card is not inserted or is not being accessed.
L Serial interface COM1: connects a RS232C or RS422-485 (Serial) cable (from the host PLC) to the unit (COM1 port).
M Power input terminal block: connects the units power cable’s input and ground wires to the unit.
N Serial interface COM2: connects a RS485 (serial) cable (from the host PLC) to the unit (RS485 port).
O Ethernet interface (10Base-T/100Base-TX) (except XBT GK2120): RJ-45 connector is used.
P USB host interfaces (USB1.1): connects a data transfer cable, USB-compatible printer, peripherals, or a PLC USB terminal port to the XBT GK.
The maximum communication distance is 5 m.
Q RS485 line polarization selector switch.
Side XBT GK2000 series Part Identification
J
File details come from the government source that posted it. Updated .