Part_10_-_Toe_Seep_Modifications_Plans_and_Specs_4-7-2015.pdf
PDF 2 MB Posted
- Solicitation number
- DQ1 FAAA FEEA2015000000000001 4
- Issued by
- Rio Grande County, Denver City, Colorado
About this file
This file is a maintenance and technical specifications document for XBT display units and SSI Technologies pressure transducers, not a state and local contract opportunity document. The file contains operational maintenance procedures and periodic check points for XBT GT5000/6000/7000 series touchscreen display panels, including instructions for regular cleaning, gasket replacement and inspection, and backlight replacement protocols. Operating specifications require temperatures between 0°C to 50°C, humidity levels between 10% to 90% RH, input voltage between 19.2 to 28.8 VDC, and a corrosive gas-free atmosphere. The document includes detailed safety warnings regarding hot backlight areas, exposed electrical components, and fragile glass components, with instructions to disconnect all power and communication cables before servicing. The file also references SSI Technologies' product line of bulk micro-machined absolute and gage pressure transducers and transmitters.
This document does not contain information typical of a state and local contract opportunity, such as pricing terms, contract awards, set asides, incumbent contractors, funding sources, or contract terms and renewal options. The file appears to be a product maintenance manual and technical specification sheet rather than a procurement document or contract opportunity notice.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Maintenance
198 35010372 9/2007
Regular Cleaning
Cleaning the display
When the surface or the frame of the display gets dirty, soak a soft cloth in water with a neutral detergent, wring the cloth tightly, and wipe the display.
Do not use hard or pointed objects to operate the touch-screen panel, since it can damage the panel surface.
Do not use paint thinner, organic solvents, or a strong acid compound to clean the unit.
Cleaning the Gasket
The gasket protects the unit and improves its water resistance.
Change the gasket at least once a year, or as soon as scratches or dirt become visible.
During normal maintenance and reinstallation, check the gasket for dirt and scratches.
Inserting the Gasket
The gasket must be inserted correctly into the groove to comply with IP65.
The upper surface of the gasket should protrude approximately 2 mm [0.08 inch] out from the groove. Verify that the gasket is correctly inserted before installing the unit into a panel.
Note: Be sure the gasket's seam is inserted into the straight bottom section of the groove. Inserting it into a corner may lead to eventual tearing.
35010372 9/2007 199
Periodic Check Points
Operation Environment
The operating temperature should be within the allowable range (0 °C to 50 °C) (32 °F to 122 °F).
The operating humidity should be within the specified range (10 %RH to 90 %RH), dry bulb temperature of 39 °C (102 °F) or less.
The operating atmosphere should be free of corrosive gases.
Electrical Specifications
The input voltage should be within 19.2 to 28.8 VDC.
Related Items Are all power cords and cables connected properly? Have any become loose?
Are all mounting brackets holding the unit securely?
Are there many scratches or traces of dirt on the installation gasket?
200 35010372 9/2007
Replacing the Backlight
Introduction The following maintenance applies only to the XBT GT5000/6000/7000 series units.
There are no serviceable parts inside the XBT GT1000/2000/4000 and the XBT GK series.
The XBT GT5000/6000/7000 series units’ backlight can be replaced by the customer. Please see the Instruction Sheet that comes with replacement backlights for details on how to replace the backlight. Contact your local distributor for more information.
If the unit's backlight burns out and the unit is not set to standby mode, the panel remains active.
BACKLIGHT AREA IS HOT
Let the product cool down for 10 minutes before removing the backlight.
Wear gloves to touch the inner components.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
EXPOSED ELECTRICAL COMPONENTS
Remove power cords and disconnect all cables, including communication cables, before opening the product.
Do not open the product for any reason except backlight replacement.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
BACKLIGHT IS FRAGILE
Do not touch the glass directly.
Do not try to remove the power cord.
Failure to follow these instructions can result in injury or equipment damage.
WARNING
WARNING
CAUTION
35010372 9/2007 201
How to Determine if the Backlight is Burned Out
If your unit's backlight suddenly turns OFF, use the following steps to determine if the backlight is actually burned out:
If the unit's Backlight Control is not set and the screen has gone blank, your backlight is burned out.
If the unit's Backlight Control is set to standby mode, the screen has gone blank, and touching the screen or performing another input operation does not cause the display to reappear, your backlight is burned out.
SSI TECHNOLOGIES, INC.
P. O. Box 5011 3200 Palmer Drive Janesville, WI 53547-5011 Phone: (608)757-2000 Fax: (608)757-2009
SSI Technologies MediaSensor� Absolute & Gage Pressure Transducers
Product Overview
Product Description SSI�s line of bulk micro-machined, absolute & gage pressure transducers and transmitters for both harsh and benign media with the superior accuracy of <±0.5% represents a significant cost savings over currently available pressure transducers. These compact, robust sensors measure pressures from 15 Psi to 3,000 Psi and are well suited for a variety of automotive, industrial and commercial applications. SSI, a leading OEM supplier of automotive sensors � having delivered more than 100 million sensors to its customers, offers the MediaSensor�, targeted at industrial and commercial applications where cost, size, and performance are critical.
Typical Applications Refrigeration Fuel Cells Pumps Hydraulics Process Control Spraying Systems
Pneumatics Compressors Flow Robotics Agriculture Hydrogen Storage
Standard Full Scale Pressure Ranges
15, 50, 75, 100, 200 and 300 Psig
500, 750, 1000, 1500, 2000, and 3000 Psis
15, 50, 75, 100, 200, 300, 500, 750, 1000, 1500, 2000, and 3000 Psia
Improved Accuracy Lower Pressure Ranges M12 & Mini DIN Connectors
MediaSensor� with integrated signal conditioning
(shown with Packard Connector and Integral Harness)
Special Features Superb Accuracy - <±0.5% Robust Package - All laser-welded stainless steel design for optimal media isolation Maximum Flexibility - Custom ASIC provides signal conditioning for calibration and temperature compensation.
Standard and custom options available Compact size, excellent price/performance ratio 5 Volt input with 0.5 � 4.5 Volt output 8 - 30 Volt input with 4 � 20 mA & 1 � 5 Volt output
Call us at (888) 477-4320 or visit our Web Site: http://ssitechnologies.com
SSI TECHNOLOGIES, INC.
Corporate Headquarters 3200 Palmer Drive Janesville, WI 53547-5011 Phone: (608)757-2000 Fax: (608)757-9019
SSI Technologies Media Sensor� Absolute & Gage Pressure Transducers
Product Overview
Performance Specifications (all values at 22oC unless noted otherwise)
Output Type 0.5 to 4.5 Volts 4 � 20 mA 1 � 5 Volts
Accuracy1 < 0.50% FS < 0.50% FS < 0.50% FS Zero & Span Error < 0.25% FS < 0.25% FS < 0.25% FS Thermal Error (-40oC to 105oC) < 0.50% FS < 0.50% FS < 0.50% FS Total Error < 1.0% FS < 1.0% FS < 1.0% FS Stability (Typical) < 0.25% FS / Year < 0.25% FS / Year < 0.25% FS / Year Zero Pressure Offset 2 0.50 V 4.0 mA 1.0 V Full Scale Output3 4.5 V 20 mA 5.0 V Operating Temperature -40 to 105oC -40 to 105oC -40 to 105oC Storage Temperature -40 to 105oC -40 to 105oC -40 to 105oC Proof Pressure 3 X FS 3 X FS 3 X FS Burst Pressure Absolute Pressure Transducers
10 X FS or 15,000 Psia (whichever is less)
10 X FS or 15,000 Psia (whichever is less)
10 X FS or 15,000 Psia (whichever is less)
Burst Pressure Gage Pressure Transducers
3 X FS 3 X FS 3 X FS
Electrical Specifications
Output Type 0.5 to 4.5 Volts 4 � 20 mA 1 � 5 Volts
Supply Voltage 5 +/- 0.5 8 to 30 Volts 8 to 30 Volts Supply Current < 6 mA Not Applicable < 3 mA Output Current 0.45mA Max
(Sink or Source) Not Applicable 0.45mA Max
(Sink or Source)
Response Time < 1 ms < 1 ms < 1ms
Reliability and Environmental Performance
Test Conditions Value Units
Wetted Materials 304L & 316L Stainless Steel - - Pressure/Temperature Cycles4 0 to FS @ 8Hz; and �40oC to 105oC >1.8x106 Cycles Thermal Shock 105oC to �40oC, 0.5 hr soaks at Temp. (2s Transfer) 250 Cycles Vibration 10 to 2050 Hz, 20 Sinusoidal, 3 Axes 144 Hours EMC Compatibility5 10 Volts/meter per EN 61000-4-3 Humidity 85oC and 90% to 95% R. H. 250 Hours Weight Model 41 with M12 x 1.5 6g 304L Stainless Port 85 Grams 1Includes hysteresis, repeatability, & non-linearity (BFSL) 4Pressure cycling performed at rated full scale pressure.
2Transducer output @ 0 Psia, 0 Psig, or 0 Psis(consult factory for other options)
5Higher levels of EMC Compatibility are available upon request.
3Transducer output @ Pressure Range + 14.5 Psia
Watertronics Pressure Transducer P/N 69-20-1740
Transducer label
SUMMITVILLE DAM IMPOUNDMENT DRAFT PUMP STATION STANDARD OPERATING PROCEDURES
DAMID: 210103
APPENDIX B
ELECTRICAL EQUIPMENT OPERATION AND MAINTENANCE MANUAL
ONE HUNDRED YEARS IN BUSINESS
12150 East 112th Avenue, Henderson, CO 80640 p 303.286.8000 f 303.286.1811 www.sturgeonelectric.com
Summitville MineSummitville Mine
Water Treatment Plant
Magnetic Flow Meter - November 2012
8119 Shaffer Parkway, Unit C Browns Hill Engineering and Controls
PROVIDED BY:
Magnetic Flow Meter November 2012
Project Manager: Lino A Alvarez Job Id: 10-164
8119 Shaffer Parkway, Unit C
Operations & Maintenance Manual
Littleton, Colorado 80127 720.344.7771
Flow Flow Duration V target V meas. o.r.* Outp.** [%] [l/s] [s] [mA] Tolerance limit: ±0.5% o.r.* ± Zero stability
40.2 10.1 30.1 10.42
100.5 25.3 30.1 20.07
*o.r.: of rate
**Calculated value (4 - 20 mA)
Flow
100%)
20925075-2854010
1000202150 FCP-7.1.2
Calibration rig
25.1327 l/s
-0.06
[l]
-0.02
Purchase order number
Service interface
Water temperatureTag Nº
Order code
Order Nº/Manufacturer
Transmitter/Sensor
Serial Nº
US-3004885701-10 / Endress+Hauser Flowtec AG
50W80-HRGA1AK5BAAA
19.09.2012
-1
-1.5
Measured error % o.r.
Calibrated full scale
Calibrated output
79.5 °F Zero point
50 60
Page 1 / 1
1.0153 Calibration factor
F-68700 Cernay / CH-4153 Reinach
Rue de l'Europe 35 / Kägenstrasse 7
Date of calibration
Endress+Hauser Flowtec AG
Endress+Hauser Flowtec operates ISO/IEC 17025 accredited calibration facilities in Reinach (CH), Cernay (FR), Greenwood (USA), Traceability to the national standard for all test instruments used for the calibration is guaranteed.
à Aurangabad (IN) and Suzhou (CN).
PROMAG 50 W 3"
[l]
F8197919000
760.048
303.615 303.567
759.565
303.613 0.02 10.4340.2 10.1 30.1 303.556
100 [%]
0.5
30 80
1.5
- - - - - -0.5
J. Breda Operator
Certified acc. to
ISO 9001
For detailed data concerning output specifications of the unit under test, see Technical Information (TI), chapter Performance characteristics.
20 9040
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .