BQ_012_123-00-001_-_Answered_1-11-18_Redacted.pdf

PDF 21 KB Posted

Attached to
USS SAMPSON 8C1 DSRA
Solicitation number
N4523A-18-R-0550
Issued by

View the file

Other files

File Type Posted
N4523A-18-R-0550_Amendment_0019.pdf PDF
N4523A-18-R-0550_Amendment_0018.pdf PDF
N4523A-18-R-0550_Amendment_0017.pdf PDF
N4523A-18-R-0550_Amendment_0016.pdf PDF
BQ_029_-_J-14_Section_B_Note_A_Redacted.pdf PDF
N4523A-18-R-0550_Amendment_0015.pdf PDF
N4523A-18-R-0550_Amendment_0014.pdf PDF
N4523A-18-R-0550_Amendment_0013.pdf PDF
DDG-102_SA_288K_HAZMINCEN_POAM.PDF PDF
SA_82710K_HED_Notional_POAM_from_DDG_101_-_HED_MSProj_19Jan16.pdf PDF
USS_Sampson_IMO_IMS_J._Fagnant_2017-12-12.pdf PDF
J-18_Access_and_User_Agreement_rev_003_02122018.pdf PDF
N4523A-18-R-0550_Amendment_0012.pdf PDF
N4523A-18-R-0550_Amendment_0011.pdf PDF
BQ_028_PPT_HED_Informational_Brief_for_DDG_102.pptx PPTX presentation
262-8749116_Rev_A,_HYBRID_ELEC_DRIVE_PIPING_-_OIL_SYS_MODS_&_ML.pdf PDF
235-8749114_Rev_A,_HYBRID_ELEC_DRIVE_CONSOLIDATED_ELEC_MODS_&_ML.pdf PDF
182-8749113_Rev_A,_HYBRID_ELEC_DRIVE_HULL_OUTFIT,_STRUCT_&_FDN_MODS_&_ML.pdf PDF
555-8749121_Rev_A,_HYBRID_ELEC_DRIVE_PIPING_-_FIRE_PROTN_MODS_&_ML.pdf PDF
551-8749120_Rev_A,_HYBRID_ELEC_DRIVE_PIPING_-AIR_SYS_MODS_&_ML.pdf PDF
BQ_028_980-90-007_clarification_Redacted.pdf PDF
N4523A-18-R-0550_Amendment_0010.pdf PDF
N4523A-18-R-0550_Amendment_0009.pdf PDF
DDG_102_DSRA_A-7_4720_Report_dtd_18_DEC_17.pdf PDF
BQ_027_4720_request_Redacted.pdf PDF
N4523A-18-R-0550_Amendment_0008.pdf PDF
N4523A-18-R-0550_J-12_PPI_Q_010_Redacted.pdf PDF
J-1_Work_Package_ERRATA_6.pdf PDF
644-8718346-ARR03_REV-A_SANITARY_ARR_MODS.pdf PDF
BQ_026_Missing_Refs-Answered_Redacted.pdf PDF
BQ_025_Missing_Refs-Answered_Redacted.pdf PDF
505-8718348-PIPE20_REV-A_SANITARY_PIPE_MODS.pdf PDF
512-8718350-VENT52_REV-A_VENTILATION_MANUFACTURING_DETAILS.pdf PDF
512-8718344-VENT10_REV-A_BERTHING_VENT_MODS.pdf PDF
331-8718345-ELEC30_REV-A_BERTHING_ELEC_MODS.pdf PDF
640-8718343-ARR01_REV-A_BERTHING_ARR_MODS.pdf PDF
512-8718347-VENT12_REV-A_SANITARY_VENT_MODS.pdf PDF
331-8718349-ELEC32_REV-A_SANITARY_ELEC_MODS.pdf PDF
BQ_024_Missing_Ref_-_Redacted.pdf PDF
BQ_007_437-012-001_Para_3.2_-_Redacted.pdf PDF
BQ_022_980-90-007_References-Redacted.pdf PDF
BQ_21_123-21-001_-_Redacted.pdf PDF
BQ_005_437-012-001_Missing_Drawings_-_Redacted.pdf PDF
BQ_023_Missing_Refs_-_Redacted.pdf PDF
BQ_018_123-10-001_-_Redacted.pdf PDF
BQ_016_588-21-001_-_Redacted.pdf PDF
BQ_019_123-10-001_-_Redacted.pdf PDF
BQ_009_Clarification_-_Redacted.pdf PDF
BQ_015_588-21-001_-_Redacted.pdf PDF
N4523A-18-R-0550_Amendment_0007.pdf PDF
Show 40 more

Latest 50 of 183 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment J-12

N4523A-18-R-0550 Pre-Proposal Information (PPI) Form

One question per form

DATE OF REQUEST: 1/10/18 QUESTION NO: 012

SHIP/HULL NO: 102 WORK ITEM/CSWT NO: 123-00-001

CONTRACTOR: CONTRACTOR POC & PHONE:

PARA. NO: 3.1.3 PAGE NO: ATTACH. NO:

CONTRACTOR QUESTION:

Paragraph 3.1.3 of item 123-00-001 Tank and Void Open, Pump, Clean and Gas Free has the KTR accomplishing 009-05 access cuts.

Access cuts are not typically needed in order to accomplish cleaning and pumping of tanks. If access cuts are required, please indicate how many access cuts will be required for this item.

DO NOT WRITE BELOW THIS LINE

(FOR GOVERNMENT USE ONLY)

Refer to FY-18 CH-2 NAVSEA Standard Item 009-05 Paragraph 3.1 Submit one legible drawing or sketch of each proposed temporary access cut to the ship structure or engine enclosure and a list of each proposed bolted/riveted access removal to the SUPERVISOR 3 days prior to making the cuts or removing the bolted/riveted access. For a nuclear-powered vessel, submit drawing/sketch of each proposed temporary access cut to the SUPERVISOR 5 days prior to making cut or removing the bolted/riveted access.

Manhole Covers and HVAC (aka Butterworth) Covers are bolted accesses to tanks, voids, and compartments.

PLANNER

REVIEW

N/A DATE: N/A SUPERVISOR REVIEW: D Richey DATE: 1/11/18

CODE 230

REVIEW: N/A DATE: N/A ADV PLAN REVIEW: N/A DATE: N/A

SPEC CHG: Y/N N/A DWG/REF CHG. Y/N N/A RQMTS CHG: Y/N N/A MAT'L CHG: Y/N N/A

RESPONSE TO SEA 02:

File details come from the government source that posted it.