Approved N32205R4254 AMEND 004 Approved.docx
DOCX document 874 KB Posted
- Attached to
- SOLICITATION USNS SUPPLY ROH Federal contract opportunity
- Solicitation number
- N3220522R4254
About this file
This document is an amendment to a federal solicitation for ship repair and maintenance work on the USNS Supply. The amendment provides clarification questions and answers from prospective contractors regarding various work items specified in the solicitation. Key details include work items for fire and smoke detection system upgrades, cargo refrigeration plenum repairs, potable water tank preservation, and chain locker painting. Pipe sizes, lengths, and quantities are clarified. Missing technical references and drawings are also provided to support contractor pricing. Water jetting is identified as an acceptable alternative to grit blasting for cleaning chains and anchors.
View the file
Other files for this federal contract opportunity
Show all 34
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N3220522R4254
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION B - SUPPLIES OR SERVICES AND PRICES
The following have been added by full text:
RFC CLARIFICATION QUESTIONS 3.
REQUEST FOR SPECIFICATION CLARIFICATION
1. SPECIFICATION ITEM NO.: 0569
PARAGRAPH / SECTION NO:
TITLE: FIRE AND SMOKE DETECTION AND ALARM SYSTEMS (1YR)(SCSI)
QUESTION: We have been notified by CONSILIUM SAFETY that the system installed on the USNS SUPPLY is no longer supported with parts. An upgrade is recommended. Is this the direction that the Government would like to have priced?
ANSWER: No this is not the direction. WI changes will be handled via change order if required.
2. SPECIFICATION ITEM NO.: 0514
PARAGRAPH / SECTION NO: 3.1, 3.2 & 7.1.6
TITLE: CHT Piping Repairs Rev 30AUG2021 QUESTION: Please provide pipe size, footage & the amount of fittings required per paragraph.
ANSWER: Requested information is in WI specified DWG. Please see image below.
3. SPECIFICATION ITEM NO.: 0535
PARAGRAPH / SECTION NO: 3.1.1 through 3.1.5, 7.3.3 & 7.5
TITLE: PIPING REPAIR VARIOUS
QUESTION: Please provide pipe sizes, footages & the amount of fittings required per para. 3.1.1 through 3.1.5.
ANSWER: Requested information is located in the WI specified DWG.
4. SPECIFICATION ITEM NO.: 0535
PARAGRAPH / SECTION NO: Para. 2.1.1
TITLE: PIPING REPAIR VARIOUS
QUESTION:
1. PARAGRAPH 2.1.1 FIRE MAIN REDUCING ELBOW. Is the reducing elbow 8” to 6”? Is there a flanged connection? If so, are the flanges RFSO, 150 psi?
1. Note 34 references drawing 804 – 1385916 can this be provided?
1. Can pictures of all required work be taken and supplied?
ANSWER: Reducing elbow is 8” to 6”. Additionally, see attached pictures below clarifying flange connection, RFSO and psi requirement. Note (34), and question 3 are addressed as well.
5. SPECIFICATION ITEM NO.: 0548
PARAGRAPH / SECTION NO: 3.1
TITLE: UNREP RECEIVING STATION REPAIR-DFM Rev 1 QUESTION: Paragraph 3.1 states that the work is located on the 01 level but the pictures supplied seem to be of the 02 level. Can the 01 level be verified?
ANSWER: Pictures in the WI are on the 01 Level Main deck.
6. SPECIFICATION ITEM NO.: 0570
PARAGRAPH / SECTION NO: 7.4.1 / 7.4.1a / 7.4.2
TITLE: PORTABLE FIRE EXTINGUISHER SYSTEM (1 YR)
QUESTION: Paragraph 7.4.1 lists 105 cylinders to be examined. Paragraph 7.4.1a identifies 35 cylinders and paragraph 7.4.2 states to replace 35 cylinders. Are these one and the same?
ANSWER: The 35 cylinders to be replaced are the General manufactured model. They cannot be serviced. Yes, they are one and the same.
7. SPECIFICATION ITEM NO.: 0607
PARAGRAPH / SECTION NO: 7.3.3.a-b TITLE: INTERIOR CPC REPLACMENT 30AUG2021 Rev1 QUESTION: Paragraphs 7.3.3.a-b - please provide locations and interferences in way of the requirements of these paragraphs. If not, please provide an expected amount of interferences and expected locations for bidding purposes.
ANSWER: I will provide pictures via DodSafe, showing the location of the requirement. Note space in question is utilized for Medical Services and will need to be well protected and clean.
8. SPECIFICATION ITEM NO.: 0607
PARAGRAPH / SECTION NO: 7.3.3.c TITLE: INTERIOR CPC REPLACMENT 30AUG2021 Rev1 QUESTION: Paragraph 7.3.3.c calls for three drains to be required. What are they required for? Where are they? What size?
ANSWER: Image and dimensions of a Standard Navy Drains see DWG 1385789 Type C 3” will be sent via Dodsafe.
9. SPECIFICATION ITEM NO.: 0607
PARAGRAPH / SECTION NO: 7.3.6.b TITLE: INTERIOR CPC REPLACMENT 30AUG2021 Rev1 QUESTION: Paragraph 7.3.6.b calls for replacing door sills. Does this mean provide and install new door sills or reinstall removed existing door sills? If new sills are required please provide details and amounts.
ANSWER: Sills can be reused or provided by the ship
10. SPECIFICATION ITEM NO.: 0542
PARAGRAPH / SECTION NO: Various TITLE: SSDG HMSO Refurbishment QUESTION: Paragraph 1.1 states to work in conjunction with Work Item 251 (which is overhauling of (5) Woodward governors). Paragraph 7.6 states to refurbish (5) governors. Paragraph 7.6.4 states to package and crate turbochargers, then paragraph 7.6.5 states to transport governors to an OEM repair facility. Please clarify work item. Also, in paragraph 7.1 it talks about cutting accesses to remove governors and HMSO. Is this correct ? Please advise.
ANSWER: Please see correct WI 0542 sent via Dodsafe.
11. SPECIFICATION ITEM NO.: 0536
PARAGRAPH / SECTION NO: 2.2 / 2.5
TITLE: Cargo Refrigeration Plenum Repairs QUESTION: Please provide the following references: 2.2 NAVSEA DWG No. 6361193F COMP ARR A2-015 16 FLAT FR 432-455 (CTR) and 2.5 NAVSEA TM S6260-BJ-GTP-010 Electric Motor Repair ANSWER: Please reference TM S6260-C3-085-8801 provided Dodsafe.
12. SPECIFICATION ITEM NO.: 0574
PARAGRAPH / SECTION NO: 2.1.2 / 2.1.5
TITLE: FIRE DOORS AND SHUTTERS (1YR)
QUESTION: Please provide the following references: 2.1.2 Tech Manual L-T4718-COT-010, 26” W x 54” H Electro-Hydraulic Sliding Watertight Doors for T-AOE 6 Class Ships and 2.1.5 Damage Control Book 800-7096879, AOE 8 Fast Combat Support Ship ANSWER: References for 2.1.2 and 2.1.5 provide via DodSafe.
13. SPECIFICATION ITEM NO.: 0602
PARAGRAPH / SECTION NO: 2.1.1 / 2.2.1
TITLE: LAUNDRY EQUIPMENT SERVICE
QUESTION: Please provide the following references: 2.1.1 NAVSEA Technical Manual S9086-V4-STM-010, NSTM Chapter 655 Shipboard Laundry and 2.2.1 Laundry Equipment List ANSWER: Please see reference provided Dodsafe.
14. SPECIFICATION ITEM NO.: 0105
PARAGRAPH / SECTION NO: 2.3 / 2.5 / 2.6 / 2.7
TITLE: HANGER HEAD DECK REPLACEMENT
QUESTION:
Please provide the following references:
2.3. NAVSEA Drawing No. 8617070_H Assembly Drawing
2.5. NAVSEA Drawing No. 6361895_E OUTFITTING OF SANITARY SPACES MN DK & ABOVE
2.6. NAVSEA Drawing No. 6360462_F Arrangement of Electrical Equipment 02 LVL FR 585 AFT
2.7. MSC Drawing No. 8385011_A Selected Record Drawing Plumbing Soil & Waste Drains System ANSWER: Requested references sent via Dod Safe.
15. SPECIFICATION ITEM NO.: 0106
PARAGRAPH / SECTION NO: 2.3 / 2.5 / 2.6 / 2.7
TITLE: SELF SERVE LAUNDRY DECK REPLACEMENT
QUESTION:
Please provide the following references:
2.3. NAVSEA Drawing No. 8617070_H Assembly Drawing
2.5. NAVSEA Drawing No. 6361895_E OUTFITTING OF SANITARY SPACES MN DK & ABOVE
2.6. NAVSEA Drawing No. 6360462_F Arrangement of Electrical Equipment 02 LVL FR 585 AFT
2.7. MSC Drawing No. 8385011_A Selected Record Drawing Plumbing Soil & Waste Drains System ANSWER: Requested references provided DodSafe.
16. SPECIFICATION ITEM NO.: 0569
PARAGRAPH / SECTION NO: 2.1.4
TITLE: SELF SERVE LAUNDRY DECK REPLACEMENT
QUESTION: Please provide the following reference: 2.1.4 MSC Drawing No. 436-8394042, Fire and Smoke Detection System Installation is missing ANSWER: Requested reference for Fire and Smoke Detection System provided via DodSafe.
17. SPECIFICATION ITEM NO.: 0603
PARAGRAPH / SECTION NO: 7.5 & 7.6
TITLE: ACCOM LADDERS REFURBISH AND WEIGHT TEST
QUESTION: Please clarify the requirement to refurbish as listed in paragraph 7.5 & 7.6
1.1 ANSWER: Completely disassemble ladder, ladder platforms and treads.
1.1.1 For bidding purposes:
a. Assume four (4) electric hoists will require removal, inspection, and weight tests at 125% of reted load.
b. Assume 300 linear inches of aluminum welding is required.
c. Assume 200 Teflon bushings for feathering treads and feathering bar require replacement.
d. Assume replacement of fifty (50) 1/4-inch toggle bolts and lanyards, fifty (50) 3/8-inch toggle bolts and lanyards, (10) 1/2-inch toggle bolts and lanyards and ten (10) 1-inch toggle bolts and lanyards will require replacements.
e. Assume eight (8) each hull mounted vangs for securing lower platform will require replacement. Coordinate work with gas free work under Work Items 020 and 021.
1.2 Refurbish J-davits, outriggers, bail brackets, platforms, ladders, treads, and handrails; re-install on vessel and grease moving parts.
1.3 Refurbish securing pad eyes and bail bracket attachment points, bail bracket latches, and stanchion bolting-in areas on the side shell.
18. SPECIFICATION ITEM NO.: 0510
PARAGRAPH / SECTION NO: 7.1.2
TITLE: Provide Pallet Conveyor Restoration QUESTION: Para. 7.1.2, please provide additional information. Review of 2.2 did not yield any information on bracket fabrication.
ANSWER: Bracket fabrication is located in the Pallet drawing
19. SPECIFICATION ITEM NO.: 0512
PARAGRAPH / SECTION NO: 2.4
TITLE: Renew NR1 SSDG Saltwater Strainer Foundation QUESTION: Please provide the following missing references:
Reference 2.4 DWG 085-8385180 General Arrangement ANSWER: Requested references provided via DodSafe.
20. SPECIFICATION ITEM NO.: 0520
PARAGRAPH / SECTION NO: 2.1 – 2.4
TITLE: Provide Pallet Conveyor Restoration
QUESTION:
Please provide the following references:
2.1 NAVSEA Drawing No. 6359950, Arrangement of Auxiliary Pump Room.
2.2 NAVSEA Drawing No. 6361372, Piping Unit 722 Auxiliary Pump Room.
2.3 NAVSEA Drawing No. 6361373, Structural Unit 722 Auxiliary Pump Room Gratings & Misc Foundations Frame 130-152 (Port)
2.4 MSC Drawing No. 085-8385180, General Arrangement
ANSWER: References provided via DodSafe.
21. SPECIFICATION ITEM NO.: 0535
PARAGRAPH / SECTION NO: Various
TITLE: PIPING REPAIR VARIOUS
QUESTION: Items 3.1.1, 3.1.2, 3.1.3, 3.1.4, & 3.1.5 do not provide any dimensional data for the items described; please provide details such as pipe size, schedule, length, quantities, etc. as applicable per item.
ANSWER:
CHT RM No. 1/FWD MSD RM 3-161-1-Q/3-183-1-Q CHT PMP No. 1 SUCT PRESSUE GA ROOT Contractor Supply
| Two 3inch diameter 90⁰ Sweeping Braze Elbows 400W |
| 1ft length of 3inch diameter CuNi Pipe |
| One 1/2inch CuNi Socket Weld Half Coupling |
| 1ft length of 1/2inch diameter CuNi Pipe |
| One 1/2inch Braze Ball Valve |
CHT/MSD/OVBD Piping Contractor Supply
| 2ft length of 4inch diameter CuNi Pipe |
| Two 4inch diameter CuNi Butt Weld 45⁰ Elbows |
| One 4inch diameter CuNi Butt Weld Tee |
AFT MSD RM 2-667-1-A
AFT CHT/MSD/OVBD Piping Contractor Supply
| 3ft length of 4inch diameter CuNi Pipe |
| One 4inch diameter CuNi Butt Weld Tee |
| One 4inch diameter CuNi Butt Weld 90⁰ Elbow |
| One 1½inch CuNi Clean Out |
| One 1½inch NPT threaded brass cap |
No. 3 MSD Overboard Piping Contractor Supply
| 2ft length of 3/4inch CuNi Pipe |
| One 3/4inch diameter CuNi Braze Union |
| One 3/4inch diameter CuNi 90⁰ Braze Elbow |
| One 3/4inch diameter CuNi Socket Weld Half Coupling |
No. 2 CHT RM 3-605-0-Q CHT/MSD/OVBD Pipping Contractor Supply
| One 4inch diameter CuNi 90⁰ Butt Weld Sweeping Elbow |
| 3ft length of 4inch diameter CuNi Pipe |
No. 3 and No. 4 CHT Pump Discharge Contractor Supply
| 5ft length of 3inch diameter CuNi Pipe |
| Two 3inch diameter 8 bolt Braze Flanges |
| One 3inch diameter CuNi 90⁰ Sweeping Butt Weld Elbow |
| One 3inch diameter CuNi Tee |
| One 3inch to 4inch Butt Weld Concentric Reducer |
| One 4inch 8 bolt Braze Flange |
Vestibule to Berthing No. 9 2-612-1 CHT/MSD/OVBD Pipping Contractor Supply
| 2 4inch diameter CuNi 90⁰ Sweeping Butt Weld Elbows |
| 1ft length of 4inch diameter Pipe |
Crew WC 2-616-0-L MSD to CHT Overflow Pipping Contractor Supply 5ft length of 5inch diameter CuNi Pipe
CHT/MSD/OVBD Pipping Contactor Supply 2ft length of 4inch diameter CuNi Pipe
Locations to be determined for pricing:
30 Feet of 4 inch CUNI pipe 30 Feet of 5 inch CUNI pipe Assume all locations will not require staging.
22. SPECIFICATION ITEM NO.: 0157
TITLE: Potable Water Tank Preservation QUESTION: The item provides capacity and cubic feet (3.1.1) for each tank, but no surface area. Please provide the square footage of each tank listed.
ANSWER: See below Potable Water Tanks
| Description |
| Location |
| 100% Capacity |
(gals) Area (sqft)
| Potable Water Tank |
| 7-477-2-W |
| 22655 |
| 3443 |
| Potable Water Tank |
| 7-488-1-W |
| 19545 |
| 2921 |
| Potable Water Tank |
| 7-488-2-W |
| 19545 |
| 2921 |
| Potable Water Tank |
| 7-499-1-W |
| 16426 |
| 2162 |
23. SPECIFICATION ITEM NO.: 0910
TITLE: CHAIN AND LOCKER PAINTING
QUESTION: Para. 7.2.4 directs to grit blast the chains, anchors, etc. to an SP-10. Due to the cost of dust containment, grit cleanup and interferences with other interfacing hull work could UHP water blasting to a WJ-2M be utilized?
ANSWER: Water jetting is acceptable and preferred