Lead_Survey_Report.pdf

PDF 2 MB Posted

Attached to
Haven on Vine Renovation Project State and local contract opportunity
Solicitation number
RFP2025-010
Issued by
Polk County, Lake Harbor CDP, Florida

About this file

The document is a Lead-Containing Paint Survey Report prepared by GLE Associates, Inc. for the City of Kissimmee, Florida, focusing on the Haven on the Vine property located at 1815 W. Vine Street. The survey was conducted on July 21, 2023, by Mr. Zac Klarich, who collected nine paint samples from Buildings 1, 2, and the Gym to identify potential lead-containing paint. The investigation was performed to provide information needed to comply with OSHA's Lead Exposure in Construction standards and to support future demolition or renovation activities.

The analytical results from EMSL Analytical, Inc. revealed that none of the nine paint samples tested contained lead concentrations above the laboratory's detection limits. All samples from interior and exterior surfaces of the buildings, including common walls, ceilings, bathrooms, gym, and reception areas, showed lead concentrations less than 0.021% by weight. The report includes a disclaimer that due to the inaccessibility of some building elements, not all potential lead-containing paint may have been located and identified. The survey was part of the broader due diligence process for the Haven on the Vine Renovation Project, which aims to transform a former Super 8 hotel into affordable housing units.

View the file

Other files for this state and local contract opportunity

Other files attached to Haven on Vine Renovation Project, newest first.
File Type Posted
abstract._RFP2025-010_Haven_on_Vine_Project_Renovation_Project.pdf PDF
Addendum_2_RFP2025-010_Haven_on_Vine_Restoration_Project.pdf PDF
2025-05-07_REV_1_Sheets.dwf.pdf PDF
E001_-_ELECTRICAL_-_GENERAL.pdf PDF
Addendum_2_RFP2025-010_Haven_on_Vine_Restoration_Project.pdf PDF
Mailboxes.pdf PDF
2025-05-07_REV_1_Sheets.dwf.pdf PDF
Mailboxes.pdf PDF
Addendum_2_RFP2025-010_Haven_on_Vine_Restoration_Project.pdf PDF
E001_-_ELECTRICAL_-_GENERAL.pdf PDF
E801_-_ELECTRICAL_SCHEDULES_AND_DIAGRAMS.pdf PDF
Super_8_Hotel_Structural_Inspection_Report_S&S.pdf PDF
Addendum_1_RFP2025-010_Haven_on_Vine_Restoration_Project.pdf PDF
Addendum_1_RFP2025-010_Haven_on_Vine_Restoration_Project.pdf PDF
LMA_Report.pdf PDF
Addendum_1_RFP2025-010_Haven_on_Vine_Restoration_Project.pdf PDF
LMA_Report.pdf PDF
Super_8_Hotel_Structural_Inspection_Report_S&S.pdf PDF
LMA_Report.pdf PDF
Super_8_Hotel_Structural_Inspection_Report_S&S.pdf PDF
1815_W_Vine_St___Sewer_Inspection.pdf PDF
Super_8_Hotel_Structural_Inspection_Report_S&S.pdf PDF
1815_W_Vine_St___Sewer_Inspection.pdf PDF
Attachment_H_-_Phase_2A_–_Energy_Conservation_Checklist-2A-022025-Signed.pdf PDF
Attachment_I_-_Phase_2B_–_Office_Building_Renovation.pdf PDF
Attachment_D_-_Phase_1A_–_43-Efficiency_Studio_Apartment_Units.pdf PDF
Attachment_L_-_General_Wage_Decision_3.29.24.pdf PDF
Attachment_M_-_Project_Location.pdf PDF
Attachment_K_–_Specifications.pdf PDF
Attachment_L_-_General_Wage_Decision_3.29.24.pdf PDF
Attachment_F_-_Phase_1B_–_Ten_Fourplex_Apartment_Building_Renovation.pdf PDF
Attachment_G_-_Phase_2A_–_40-Efficiency_Studio_Apartment_Units.pdf PDF
Attachment_H_-_Phase_2A_–_Energy_Conservation_Checklist-2A-022025-Signed.pdf PDF
Attachment_F_-_Phase_1B_–_Ten_Fourplex_Apartment_Building_Renovation.pdf PDF
Attachment_G_-_Phase_2A_–_40-Efficiency_Studio_Apartment_Units.pdf PDF
Attachment_D_-_Phase_1A_–_43-Efficiency_Studio_Apartment_Units.pdf PDF
Attachment_E_-_Phase_1A_–_Energy_Cals.pdf PDF
Attachment_F_-_Phase_1B_–_Ten_Fourplex_Apartment_Building_Renovation.pdf PDF
Attachment_J_-_Phase_2B_–_Energy_Conservation_Checklist-2B-022025-Signed.pdf PDF
Attachment_K_–_Specifications.pdf PDF
Attachment_E_-_Phase_1A_–_Energy_Cals.pdf PDF
Attachment_G_-_Phase_2A_–_40-Efficiency_Studio_Apartment_Units.pdf PDF
Attachment_K_–_Specifications.pdf PDF
Attachment_M_-_Project_Location.pdf PDF
RFP20205-010_HAVEN_ON_VINE_-_Renovation_Project.pdf PDF
Attachment_E_-_Phase_1A_–_Energy_Cals.pdf PDF
Attachment_M_-_Project_Location.pdf PDF
RFP20205-010_HAVEN_ON_VINE_-_Renovation_Project.pdf PDF
Attachment_L_-_General_Wage_Decision_3.29.24.pdf PDF
Attachment_L_-_General_Wage_Decision_3.29.24.pdf PDF
Show all 50

Haven on Vine Renovation Project has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1155 South Semoran Boulevard, Suite 3-1111 Winter Park, Florida 32792

407-658-4151 • Fax 407-658-4410

LEAD-CONTAINING PAINT SURVEY REPORT

Haven on the Vine Buildings 1, 2, & Gym 1815 W. Vine Street

Kissimmee, Florida 34741

GLE Project No.: 23000-28136

Prepared for:

Mr. Robert Masiku City of Kissimmee

101 Church Street, Suite 301 Kissimmee, Florida 34741

August 2023

Prepared by:

GLE Associates, Inc.

1155 S. Semoran Boulevard, Suite 3-1111 | Winter Park, Florida 32792 | 407-658-4151 | Fax: 407-658-4410 Tampa | Ft. Lauderdale | Miami | Jacksonville | Gainesville | Atlanta | Nashville

Architecture AR 0007729 • Engineer RY 5483 • Asbestos ZA 0000034 • Geology PG 1737

August 10, 2023

Mr. Robert Masiku City of Kissimmee 101 Church Street, Suite 301 Kissimmee, Florida 34741

RE: Lead-Containing Paint Survey Report Haven on the Vine Buildings 1, 2, & Gym 1815 W. Vine Street Kissimmee, Florida 34741

GLE Project No.: 23000-28136

Dear Mr. Masiku:

GLE Associates, Inc. (GLE) performed a survey to identify lead-containing paint on July 21, 2023, at Haven on the Vine buildings 1, 2, & Gym, located in Kissimmee, Florida. The survey was performed by Mr. Zac Klarich with GLE. This report outlines the sampling and testing procedures, and presents the results along with our conclusions and recommendations.

GLE appreciates the opportunity to work with you on this project. Should you have questions regarding any of the information contained in this report, please do not hesitate to contact our office.

Sincerely, GLE Associates, Inc.

Zac Klarich Robert B. Greene, PE, PG, CIH, LEED AP Junior Project Manager President

ZK/PSZ/RBG/jl

I:\Work\Asb\'23\23000\28136.City Of Kissimmee.Super 8.Bulk ACM.LMA.LBP\Report\LBP\Lead Survey Report.doc

TABLE OF CONTENTS

1.0 EXECUTIVE SUMMARY 1

1.1 Introduction 1

1.2 Facility Description 1

2.0 RESULTS 1

2.1 Lead Survey Procedures 1

2.2 Identified Suspect Lead-Containing Paint 2

Table 2.2-1 — Summary of Analytical Results

3.0 CONCLUSIONS AND RECOMMENDATIONS 4

4.0 LIMITATIONS AND CONDITIONS 4

APPENDICES

Appendix A – Analytical Results and Chain of Custody Appendix B – Personnel and Laboratory Qualifications

1.0 EXECUTIVE SUMMARY

1.1 INTRODUCTION

On July 21, 2023, a lead-containing paint survey was conducted at Haven on the Vine buildings 1, 2, & Gym, located in Kissimmee, Florida. The survey was performed by Mr. Zac Klarich with

GLE.

1.2 FACILITY DESCRIPTION

A summary of the facility investigated is outlined in the table below.

Facility Type: Apartments Construction Date: 1972-1974 Number of Floors: 2

Exterior Floor Support: Concrete Wall Support: Concrete Masonry Units (CMU) Exterior Finish: Stucco, Paint Roof System Type: Roofing Shingles

Interior Wall Substrate: Drywall, CMU Wall Finishes: Paint, Cove Base Floor Finishes: Carpet, Vinyl Floor Tile, Sheet Vinyl Flooring, Ceramic Ceiling System: Drywall Ceiling Finishes: Drywall

2.0 RESULTS

2.1 LEAD SURVEY PROCEDURES

It is GLE’s understanding that the survey was conducted to provide information needed to comply with 29 CFR Part 1926 “Lead Exposure in Construction; Interim Final Rule” for future demolition and/or renovation activities. The Scope of the “Lead Exposure in Construction;

Interim Final Rule” “…applies to all occupational exposure to lead in all construction work in which lead, in any amount, is present in an occupationally related context.” Due to the lack of a firm correlation between lead levels in paint and airborne lead levels during construction activities, OSHA has developed task-related triggers that require the implementation of the provisions required in 29 CFR Part 1926. Demolition and/or renovation activities involve tasks covered under this standard.

The survey was performed by observing and testing accessible painted component surfaces of the building. The sampling protocol used in this lead paint survey is a modified version of the survey methodology established by HUD. The protocol was modified to conform to the specific parameters of this project.

After the overall visual survey was completed, an inventory of painted surfaces was developed.

The surveyor then subdivided the areas into homogeneous areas of apparent similar paint history.

Sampling of the paint surfaces was performed by collecting representative paint chips. All samples were submitted to EMSL Analytical, Inc., an accredited laboratory recognized under EPA’s National Lead Laboratory Accreditation Program (NLLAP), located in Orlando, Florida.

These samples were analyzed by EPA Method SW 846 3050B/7000B and the results are reported in percentage of lead by weight of the paint sample (% Wt).

2.2 IDENTIFIED SUSPECT LEAD-CONTAINING PAINT

A total of nine samples of suspect lead-containing paint were collected from the facility during the survey. The results of the laboratory analyses are included in Appendix A.

A summary of the paint chip sample analytical results is outlined in the following table:

TABLE 2.2-1: SUMMARY OF ANALYTICAL RESULTS

HAVEN ON THE VINE-KISSIMMEE FL

SAMPLE

# BUILDING INTERIOR OR

EXTERIOR LOCATION LEAD CONCENTRATION (% BY WEIGHT)

L-1 Building 1 Interior Common Walls Bld. 1 Interior <0.013 % wt L-2 Building 1 Interior Ceilings, Bld. 1 Interior <0.0080 % wt L-3 Building 1 Interior Bathrooms, Bld. 1 Interior <0.021 % wt L-4 Building 1, Gym Interior Gym, Bld. 1 Interior <0.0094 % wt L-5 Building 1 Interior Reception Bathroom <0.017 % wt L-6 Building 2 Interior Building 2 Common Walls Interior <0.0080 % wt L-7 Buildings 1, 2, Gym Exterior All Buildings Exterior <0.0080 % wt L-8 Buildings 1, 2, Gym Exterior All Buildings Exterior <0.0080 % wt L-9 Buildings 1, 2, Gym Exterior All Buildings Exterior <0.0080 % wt

1 BOLD result indicates lead-containing paint.

2 The requirements of the OSHA Lead in Construction Standard 29CFR 1926.62 are invoked if any amount of lead is present in the sample; there is no minimum concentration.

3.0 CONCLUSIONS AND RECOMMENDATIONS

Analytical results indicate that Nine of the Nine painted surfaces tested did not contain concentrations (% by weight) of lead within the paint greater than the laboratory’s detection limits.

4.0 LIMITATIONS AND CONDITIONS

Due to the inaccessibility of some building elements, it is conceivable that all potential lead-containing paint within the extents of this survey may not have been located and identified. We do warrant, however, that the investigations and methodology reflect our best efforts based upon the prevailing standard of care in the environmental industry.

APPENDIX A

Analytical Results and Chain of Custody

Client Sample Description ConcentrationLab ID Analyzed Weight Lead

Collected

EMSL Analytical, Inc.

3303 PARKWAY CENTER COURT, Orlando, FL 32808 Phone/Fax: (407) 599-5887 / (407) 599-9063 http://www.EMSL.com orlandolab@emsl.com

Attn: Zac Klarich GLE Associates 1155 South Semoran Boulevard Suite 3-1111 Winter Park, FL 32792

Received: 7/21/2023 05:03 PM

City Of Kissimmee 1815 W. Vine Street

Fax: (407) 658-4410 Phone: (407) 658-4151

Project:

7/21/2023Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

342316339 CustomerID: GLEA51D CustomerPO: 23000-28136 ProjectID:

EMSL Order:

0.1509 Site: Common Walls Bld. 1 Interior 342316339-0001L-1 <0.013 % wt7/24/2023 g7/21/2023

0.2682 Site: Ceilings, Bld. 1 Interior 342316339-0002L-2 <0.0080 % wt7/24/2023 g7/21/2023

0.0944 Site: Bathrooms, Bld. 1 Interior 342316339-0003L-3 <0.021 % wt7/24/2023 g7/21/2023

0.2125 Site: Gym, Bld. 1 Interior 342316339-0004L-4 <0.0094 % wt7/24/2023 g7/21/2023

0.1152 Site: Bld 1, Reception Bathroom 342316339-0005L-5 <0.017 % wt7/24/2023 g7/21/2023

0.2601 Site: Building 2 Common Walls Interior 342316339-0006L-6 <0.0080 % wt7/24/2023 g7/21/2023

0.2669 Site: All Buildings Exterior 342316339-0007L-7 <0.0080 % wt7/24/2023 g7/21/2023

0.2989 Site: All Buildings Exterior 342316339-0008L-8 <0.0080 % wt7/24/2023 g7/21/2023

0.2565 Site: All Buildings Exterior 342316339-0009L-9 <0.0080 % wt7/24/2023 g7/21/2023

Heather Ohye, Metals Manager or other approved signatory

Test Report ChmSnglePrm/nQC-7.32.3 Printed: 7/27/2023 5:05:57 PM

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

* Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Orlando, FL AIHA LAP, LLC-ELLAP Accredited #163563

Initial report from 07/27/2023 17:05:57 http://www.EMSL.com mailto:orlandolab@emsl.com

OrderID: 342316339

OrderID: 342316339

APPENDIX B

Personnel and Laboratory Qualifications

GLE Associates, Inc.

has fulfilled the requirements of the Toxic Substances Control Act (TSCA) Section 402, and has received certification to conduct lead-based paint activities pursuant to 40 CFR Part 745.226

All EPA Administered Lead-based Paint Activities Program States, Tribes and Territories

This certification is valid from the date of issuance and expires March 02, 2024

Certification #

LBP-2060-2

Issued On

January 05, 2021

Michelle Price, Chief

Lead, Heavy Metals, and Inorganics Branch

AIHA Laboratory Accreditation Programs, LLC acknowledges that

EMSL Analytical, Inc.

3303 Parkway Center Ct Orlando, FL 32808-1040

Laboratory ID: LAP-163563 along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation Programs (AIHA LAP), LLC accreditation to the ISO/IEC 17025:2017 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following:

LABORATORY ACCREDITATION PROGRAMS

INDUSTRIAL HYGIENE Accreditation Expires: February 01, 2024

ENVIRONMENTAL LEAD Accreditation Expires: February 01, 2024

ENVIRONMENTAL MICROBIOLOGY Accreditation Expires: February 01, 2024

FOOD Accreditation Expires:

UNIQUE SCOPES Accreditation Expires:

BERYLLIUM FIELD/MOBILE Accreditation Expires:

Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC 17025:2017 and AIHA LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA LAP, LLC website (www.aihaaccreditedlabs.org) for the most current Scope.

Revision19.1: 07/28/2021

Cheryl O Morton Managing Director, AIHA Laboratory Accreditation Programs, LLC

Date Issued: 01/31/2022

Effective: 07/29/2021 Revision: 8.1

AIHA Laboratory Accreditation Programs, LLC

SCOPE OF ACCREDITATION

EMSL Analytical, Inc. Laboratory ID: LAP-163563

3303 Parkway Center Ct Orlando, FL 32808-1040 Issue Date: 01/31/2022

The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory's current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.

The EPA recognizes the AIHA LAP, LLC ELLAP program as meeting the requirements of the National Lead Laboratory Accreditation Program (NLLAP) established under Title X of the Residential Lead-Based Paint Hazard Reduction Act of 1992 and includes paint, soil and dust wipe analysis. Air and composited wipes analyses are not included as part of the

NLLAP.

Environmental Lead Laboratory Accreditation Program (ELLAP)

Initial Accreditation Date: 09/01/2007

Component, parameter or characteristic tested

Technology sub-type/Detector Method Method Description

(for internal methods only)

Airborne Dust AA NIOSH 7082 N/A

EPA SW-846 3050B N/A

EPA SW-846 3051A N/APaint AA

EPA SW-846 7000B N/A

EPA SW-846 3050B N/A

EPA SW-846 3051A N/ASettled Dust by Wipe AA

EPA SW-846 7000B N/A

EPA SW-846 3050B N/A

EPA SW-846 3051A N/ASoil AA

EPA SW-846 7000B N/A

A complete listing of currently accredited ELLAP laboratories is available on the AIHA LAP, LLC website at: http:// www.aihaaccreditedlabs.org

August 2023
Table 2.2-1 — Summary of Analytical Results
APPENDICES
Appendix A – Analytical Results and Chain of Custody
4.0 LIMITATIONS AND CONDITIONS
APPENDIX A
Analytical Results and Chain of Custody
APPENDIX B

Personnel and Laboratory Qualifications