Revised Attachment_5_Price_List_and_Scope_of_Work(1).xls
XLS spreadsheet 112 KB Posted
- Attached to
- Answer Questions
- Solicitation number
- HQ0034-12-R-0006
- Issued by
-
DOD Washington Headquarters Service
About this file
Revised Attachment 5 to the solicitation.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Base Year
| BASE YEAR - PRICE LIST AND SCOPE OF WORK | ||||
| Projects ending in .30 should be completed in 30 days, .60 in 60 days, .35 in 35 days | ||||
| DESCRIPTION | POP CALENDAR DAYS | LEASED FACILITY PRICE | PENTAGON PRICE | |
| Item No. | I. Main Entry Zone Packages: | |||
| I.1.30 | Item I.1.30 (Main Entry-Expedited): Install one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) AMAG exterior reader, (1) AMAG interior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch. Complete in 30 days | |||
| I.1.60 | Item I.1.60 (Main Entry-Standard) Install one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) AMAG exterior reader, (1) AMAG interior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch. Complete in 60 days | |||
| I.2.30 | ISSC Item I.2.30 (Main Entry-Expedited) AMAG FIPS 201_Panel_ACS_IDS_Mortise (one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) |
exterior reader, (1) interior reader, (1) alarm status indicator, (1) mortise lock, (1) Infrared motion sensor, and (1) balanced magnetic switch. Complete in 30 days I.2.60 ISSC Item I.2.60 (Main Entry-Standard) AMAG FIPS 201_Panel_ACS_IDS_Mortise (one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) exterior reader, (1) interior reader, (1) alarm status indicator, (1) mortise lock, (1) Infrared motion sensor, and (1) balanced magnetic switch.) Complete in 60 days I.3.30 ISSC Item I.3.30 (Main Entry-Expedited) AMAG FIPS 201_Panel_ACS_IDS_No Lock (one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) exterior reader, (1) interior reader, (1) alarm status indicator, (1) Infrared motion sensor, and (1) balanced magnetic switch.) Complete in 30 days I.3.60 ISSC Item I.3.60 (Main Entry-Standard) AMAG FIPS 201_Panel_ACS_IDS_No Lock (one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) exterior reader, (1) interior reader, (1) alarm status indicator, (1) Infrared motion sensor, and (1) balanced magnetic switch.) Complete in 60 days I.4.30 ISSC Item I.4.30 (Main Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_ No Lock ((1) exterior reader, (1) interior reader, (1) alarm status indicator, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
I.4.60 ISSC Item I.4.60 (Main Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_No Lock ((1) exterior reader, (1) interior reader, (1) alarm status indicator, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
I.5.30 ISSC Item I.5.30 (Main Entry-Expedited) HID FIPS 201_Panel_ACS_IDS_Electric Strike (one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) HID exterior reader, (1) HID interior reader, (1) alarm status indicator) I.5.60 ISSC Item I.5.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_Electric Strike (one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) HID exterior reader, (1) HID interior reader, (1) alarm status indicator.)
I.6.30 ISSC Item I.6.30 (Main Entry-Expedited) HID FIPS 201_Panel_ACS_IDS_Mortise (one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) HID exterior reader, (1) HID interior reader, (1) alarm status indicator) I.6.60 ISSC Item I.6.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_Mortise (one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) HID exterior reader, (1) HID interior reader, (1) alarm status indicator) I.7.30 ISSC Item I.7.30 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_No Lock (one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) exterior reader, (1) interior reader, (1) alarm status indicator, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
I.7.60 ISSC Item I.7.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_No Lock (one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) exterior reader, (1) interior reader, (1) alarm status indicator, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
I.8.30 ISSC Item I.8.30 (Main Entry): HID FIPS 201 Reader-ACS IDS-NO lock or panel ((1) exterior reader, (1) interior reader, (1) alarm status indicator, (1) Infrared motion sensor, and (1) balanced magnetic switch..)
I.8.60 ISSC Item I.8.60 (Main Entry): HID FIPS 201 Reader-No Panel-ACSIDS- No Lock ((1) exterior reader, (1) interior reader, (1) alarm status indicator, (1) Infrared motion sensor, and (1) balanced magnetic switch..)
| II. Secondary Zone Packages: | |
| II.1.30 | ISSC Item II.1.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_Electric Strike (one (1) exterior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit |
sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
II.1.60 ISSC Item II.1.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_Electric Strike (one (1) exterior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
II.2.30 ISSC Item II.2.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_Mortise ((1) exterior reader, (1) alarm status indicator, (1) mortise lock, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
II.2.60 ISSC Item II.2.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_Mortise ((1) exterior reader, (1) alarm status indicator, (1) mortise lock, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
II.3.30 ISSC Item II.3.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_ No Lock ((1) exterior reader, (1) alarm status indicator, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
II.3.60 ISSC Item II.3.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_No Lock ((1) exterior reader, (1) alarm status indicator, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
II.4.30 ISSC Item II.4.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_Electric Strike (one (1) exterior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
II.4.60 ISSC Item II.4.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_Electric Strike (one (1) exterior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
II.5.30 ISSC Item II.5.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_Mortise ((1) exterior reader, (1) alarm status indicator, (1) mortise lock, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
II.5.60 ISSC Item II.5.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_Mortise ((1) exterior reader, (1) alarm status indicator, (1) mortise lock, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
II.6.30 ISSC Item II.6.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_ No Lock ((1) exterior reader, (1) alarm status indicator, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
II.6.60 ISSC Item II.6.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_No Lock ((1) exterior reader, (1) alarm status indicator, (1) Infrared motion sensor, and (1) balanced magnetic switch.)
| III. Access Control Only Packages: | |
| III.1.30 | ISSC Item III.1.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_ES (one (1) exterior reader, (1) request to exit sensor, (1) electric strike, and (1) balanced |
magnetic switch.)
III.1.60 ISSC Item III.1.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_ES (one (1) exterior reader, (1) request to exit sensor, (1) electric strike, and (1) balanced magnetic switch.)
| III.2.30 | ISSC Item III.2.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_Mortise 9(1) exterior reader, (1) mortise lock, and (1) balanced magnetic switch) |
| III.2.60 | ISSC Item III.2.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_Mortise ((1) exterior reader, (1) mortise lock, and (1) balanced magnetic switch) |
| III.3.30 | ISSC Item III.3.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_ No Lock ((1) exterior reader and (1) balanced magnetic switch) |
| III.3.60 | ISSC Item III.3.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_No Lock ((1) exterior reader and (1) balanced magnetic switch) |
| III.4.30 | ISSC Item III.4.30 (Access Control Only Entry-Expedited) HID FIPS 201_No Panel_ACS_ES (one (1) exterior reader, (1) request to exit sensor, (1) electric strike, and (1) balanced |
magnetic switch.)
III.4.60 ISSC Item III.4.60 (Access Control Only Entry-Standard) HID FIPS 201_No Panel_ACS_ES (one (1) exterior reader, (1) request to exit sensor, (1) electric strike, and (1) balanced magnetic switch.)
| III.5.30 | ISSC Item III.5.30 (Access Control Only Entry-Expedited) HID FIPS 201_No Panel_ACS_Mortise 9(1) exterior reader, (1) mortise lock, and (1) balanced magnetic switch.) |
| III.5.60 | ISSC Item III.5.60 (Access Control Only Entry-Standard) HID FIPS 201_No Panel_ACS_Mortise ((1) exterior reader, (1) mortise lock, and (1) balanced magnetic switch.) |
| III.6.30 | ISSC Item III.6.30 (Access Control Only Entry-Expedited) HID FIPS 201_No Panel_ACS_ No Lock ((1) exterior reader and (1) balanced magnetic switch) |
| III.6.60 | ISSC Item III.6.60 (Access Control Only Entry-Standard) HID FIPS 201_No Panel_ACS_No Lock ((1) exterior reader and (1) balanced magnetic switch) |
| IV. Egress Door: | |
| IV.1.30 | ISSC Item IV.1.30 (Egress Door)- Expedited ((1) passive infrared motion sensor, (1) piezo buzzer, and (1) balanced magnetic switch.) |
| IV.1.60 | ISSC Item IV.1.60 (Egress Door) - Standard 9(1) passive infrared motion sensor, (1) piezo buzzer, and (1) balanced magnetic switch.) |
| DRS-OPR-65-05 | |
| V. Additional Devices: | |
| These devices below are strictly for adding to packages, I‐III above. | |
| V.1.30 | ISSC Item V.1.30 (Additional PIR) - Expedited (install (1) passive infrared motion sensor to an ordered package) |
| V.1.60 | ISSC Item V.1.60 (Additional PIR) - Standard (install (1) passive infrared motion sensor to an ordered package) |
| V.2.30 | ISSC Item V.2.30 (Additional Duress) - Expedited (install (1) duress button to an ordered package) |
| V.2.60 | ISSC Item V.2.60 (Additional Duress) - Standard (install (1) duress button to an ordered package) |
| V.3.30 | ISSC Item V.3.30 (Additional IDRS) - Expedited (1) integrated door release system with (2) release buttons to an ordered package) |
| V.3.60 | ISSC Item V.3.60 (Additional IDRS) - Standard ((1) integrated door release system with (2) release buttons to an ordered package) |
| V.4.30 | ISSC Item V.4.30 (Additional IDRS Button) - Expedited ((1) additional release button for an existing integrated door release system for an ordered |
package.)
V.4.60 ISSC Item V.4.60 (Additional IDRS Button) - Standard ((1) additional release button for an existing integrated door release system for an ordered package.)
V.5.30 ISSC Item V.5.30 (Additional IDRS Piezo) - Expedited ((1) additional piezo chime usually located in the back of the space for the integrated door release system for an ordered package.)
V.5.60 ISSC Item V.5.60 (Additional IDRS Piezo) - Standard ((1) additional piezo chime usually located in the back of the space for the integrated door release system for an ordered package.)
| V.6.30 | ISSC Item V.6.30 (Additional Mortise lock) - Expedited (1) mortise lock to an ordered package.) |
| V.6.60 | ISSC Item V.6.60 (Additional Mortise lock) - Standard (1) mortise lock to an ordered package.) |
| V.7.30 | ISSC Item V.7.30 (Additional BMS) - Expedited ((1) additional balanced magnetic switch to an ordered package.) |
| V.7.60 | ISSC Item V.7.60 (Additional BMS) - Standard ((1) additional balanced magnetic switch to an ordered package.) |
| V.8.30 | ISSC Item V.8.30 (Additional Glass Break) - Expedited ((1) additional glass break sensor to an ordered package.) |
| V.8.60 | ISSC Item V.8.60 (Additional Glass Break) - Standard ((1) additional glass break sensor to an ordered package.) |
| V.9.30 | ISSC Item V.9.30 (Additional Aiphone Door Video Unit) - Expedited ((1) new additional Aiphone camera) |
| V.9.60 | ISSC Item V.9.60 (Additional Aiphone Door Video Unit) - Standard ((1) new additional Aiphone camera)) |
| V.10.30 | ISSC Item V.10.30 (Additional Aiphone Sub - Desk Unit) - Expedited ((1) new Aiphone Sub desk unit.) |
| V.10.60 | ISSC Item V.10.60 (Additional Aiphone Sub - Desk Unit) - Standard ((1) new Aiphone Sub desk unit.) |
| V.11.30 | ISSC Item V.11.30 (Additional M2100 DCU & IO Boards) 9install (1) DCU Board & (2) I/O Boards.) |
| V.12.30 | ISSC Item V.12.30 (Additional M2150 DC & IO Boards) (install (1) DCU Board & (2) I/O Boards.) |
| VI. AMAG M2100 /M2150 Alarm Control Panel Accessories: | |
| VI.1.30 | ISSC Item VI.1.30 (Additional M2100 DCU & IO Boards to Existing Panel) ((1) DCU Board & (2) I/O Boards.) |
| VI.2.30 | ISSC Item VI.2.30 (Additional M2150 DC & IO Boards) - Expedited ((1) DCU Board & (2) I/O Boards.) |
| DRS-OPR-65-05 | |
| VII. New Installation of Devices to existing panels: | |
| VII.1.30 | ISSC Item VII.1.30 (New Individual PIR) - Expedited (1) new passive infrared motion sensor.) |
| VII.1.60 | ISSC Item VII.1.60 (New Individual PIR) - Standard ((1) new passive infrared motion sensor.) |
| VII.2.30 | ISSC Item VII.2.30 (New Individual BMS) - Expedited ((1) new balanced magnetic switch.) |
| VII.2.60 | ISSC Item VII.2.60 (New Individual BMS) – Standard (1) new balanced magnetic switch.) |
| VII.3.30 | ISSC Item VII.3.30 (New Individual Glass Break) - Expedited (1) new glass break sensor.) |
| VII.3.60 | ISSC Item VII.3.60 (New Individual Glass Break) - Standard (1) new glass break sensor.) |
| VII.4.30 | ISSC Item VII.4.30 (New Electric Strike) - Expedited (1) new electric strike.) |
| VII.4.60 | ISSC Item VII.4.60 (New Electric Strike) - Standard ((1) new electric strike.) |
| VII.5.35 | ISSC Item VII.5.35 (New Duress Button) (1) new duress button. |
| VII.6.35 | ISSC Item VII.6.35 (New IDRS) install (1) new integrated door release system with (2) release buttons. |
| VII.7.35 | ISSC Item VII.7.35 (New IDRS Button) (1) new release button for an existing integrated door release system. |
| VII.8.35 | ISSC Item VII.8.35 (New IDRS Piezo) (1) new interior piezo chime usually located in the back of the space for the integrated door |
release system.
| VII.9.30 | ISSC Item VII.9.30 (Aiphone Door Video System w/ Desk Master Unit) - Expedited (1) new Aiphone system that consist of (1) camera and (1) Master desk unit.) |
| VII.9.60 | ISSC Item VII.9.60 (Aiphone Door Video System w/ Desk Master Unit) - Standard (1) new Aiphone system that consist of (1) camera and (1) Master desk unit.) |
| VII.10.30 | ISSC Item VII.10.30 (New Aiphone Door Video Unit to Existing System) - Expedited (install (1) new additional Aiphone camera.) |
| VII.10.60 | ISSC Item VII.10.60 (New Aiphone Door Video Unit to Existing System) - Standard(install (1) new additional Aiphone camera.) |
| VII.11.30 | ISSC Item VII.11.30 (Additional Aiphone Sub Desk Unit to Existing System)-Expedited (install (1) new Aiphone Sub desk unit.) |
| VII.11.60 | ISSC Item VII.11.60 (Additional Aiphone Sub Desk Unit to Existing System) - Standard (install (1) new Aiphone Sub desk unit.) |
| VII.12.30 | ISSC Item VII.12.30 New Door Box Device Rough In) rough in (3) door boxes per door for devices |
| VIII. Miscellaneous Items | |
| VIII.1.30 | ISSC Item VIII.1.30 (Decommissioning One Zone or Subzone) Removal of all Equipment from zone, inventory the removed equipment, dispose of cabling, mark the zone or subzone off-line on the server, deliver the equipment to the warehouse, and submit a summary of the devices that were removed in the CDRL submittal |
| VIII.2.30 | ISSC Item VIII.2.30 (Relocate One IDRS Button) (relocate (1) release button for an existing integrated door release system.) |
| IX. Permits | |
| IX.1.30 | ISSC Item IX.1.30 (Building Permit) 1st Floor with the first door locking device (Provide and close (1) Building Permit to include one floor and the first door with a locking device.) |
| DRS-OPR-65-05 | |
| IX.2.30 | ISSC Item IX.2.30 (Building and Low Voltage Permit) 1st Floor, First Door Locking Device, 1st group of 4-devices, & wiring. (Provide and close (1) Building & Low Voltage Permit to include: one floor, the first door with a locking device, |
and low voltage wiring with the first four devices.)
| IX.3.30 | ISSC Item IX.3.30 (Low Voltage Permit) 1st group of 4-devices & wiring. (Provide and close (1) Low Voltage Permit to includes: low voltage wiring with the first four devices) | ||
| IX.4.30 | ISSC Item IX.4.30 (Low Voltage Permit-Each Additional 4-Devices over base permit) 4-devices & wiring. (This proposal is to provide for additional devices for a quantity of 4 each over a base low voltage permit.0 | ||
| IX.5.30 | ISSC Item IX.5.30 (Building Permit-Each Additional Locking Door) This proposal is for additional locking doors over the base building permit. | ||
| TOTAL | |||
| Multiply the total by 10 for evaluation purposes. | x10 | x10 | |
| Subtotal | |||
| Add $2 Million for non-priced items | $ 2,000,000.00 | $ 2,000,000.00 | |
| Grand Total | |||
| Note 1: The Price List will be reviewed annually before the option is exercised and revised as necessary by mutual agreement. | |||
| Note 2: Additional Devices and New Installation of Devices shall be compatible with the existing AMAG systems. | |||
| GOVERNMENT PROVIDED ITEMS | |||
| 2. The Government will provide necessary power and connectivity that will be installed within three feet of the devices that is represented in the system requirements matrix. | |||
| 3. If a magnetic lock is requested the Government will provide an independent fire alarm dry contact relay within three feet of the AMAG alarm control panel. | |||
| 4. All door hardware, doors, and frames will be provided by the Government. | |||
| 5. The Government will provide necessary AMAG servers and software as the current limitation is 64 panels/nodes per communications client server. |
Option Year 1
| OPTION YEAR 1 - PRICE LIST AND SCOPE OF WORK | ||||
| DESCRIPTION | POP CALENDAR DAYS | LEASED FACILITY PRICE | PENTAGON PRICE | |
| Item No. | I. Main Entry Zone Packages: | |||
| I.1.30 | Item I.1.30 (Main Entry-Expedited): Install one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) AMAG exterior reader, (1) AMAG interior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch. Complete in 30 days | |||
| I.1.60 | Item I.1.60 (Main Entry-Standard) Install one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) AMAG exterior reader, (1) AMAG interior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch. Complete in 60 days | |||
| I.2.30 | ISSC Item I.2.30 (Main Entry-Expedited) AMAG FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.2.60 | ISSC Item I.2.60 (Main Entry-Standard) AMAG FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.3.30 | ISSC Item I.3.30 (Main Entry-Expedited) AMAG FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.3.60 | ISSC Item I.3.60 (Main Entry-Standard) AMAG FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.4.30 | ISSC Item I.4.30 (Main Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_ No Lock | |||
| I.4.60 | ISSC Item I.4.60 (Main Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_No Lock | |||
| I.5.30 | ISSC Item I.5.30 (Main Entry-Expedited) HID FIPS 201_Panel_ACS_IDS_Electric Strike | |||
| I.5.60 | ISSC Item I.5.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_Electric Strike | |||
| I.6.30 | ISSC Item I.6.30 (Main Entry-Expedited) HID FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.6.60 | ISSC Item I.6.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.7.30 | ISSC Item I.7.30 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.7.60 | ISSC Item I.7.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.8.30 | ISSC Item I.8.30 (Main Entry): HID FIPS 201 Reader-ACS IDS-NO lock or panel | |||
| I.8.60 | ISSC Item I.8.60 (Main Entry): HID FIPS 201 Reader-No Panel-ACSIDS- No Lock | |||
| II. Secondary Zone Packages: | ||||
| II.1.30 | ISSC Item II.1.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.1.60 | ISSC Item II.1.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.2.30 | ISSC Item II.2.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.2.60 | ISSC Item II.2.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.3.30 | ISSC Item II.3.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_ No Lock | |||
| II.3.60 | ISSC Item II.3.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_No Lock | |||
| II.4.30 | ISSC Item II.4.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.4.60 | ISSC Item II.4.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.5.30 | ISSC Item II.5.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.5.60 | ISSC Item II.5.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.6.30 | ISSC Item II.6.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_ No Lock | |||
| II.6.60 | ISSC Item II.6.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_No Lock | |||
| III. Access Control Only Packages: | ||||
| III.1.30 | ISSC Item III.1.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_ES | |||
| III.1.60 | ISSC Item III.1.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_ES | |||
| III.2.30 | ISSC Item III.2.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_Mortise | |||
| III.2.60 | ISSC Item III.2.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_Mortise | |||
| III.3.30 | ISSC Item III.3.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_ No Lock | |||
| III.3.60 | ISSC Item III.3.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_No Lock | |||
| III.4.30 | ISSC Item III.4.30 (Access Control Only Entry-Expedited) HID FIPS 201_No Panel_ACS_ES | |||
| III.4.60 | ISSC Item III.4.60 (Access Control Only Entry-Standard) HID FIPS 201_No Panel_ACS_ES | |||
| III.5.30 | ISSC Item III.5.30 (Access Control Only Entry-Expedited) HID FIPS 201_No Panel_ACS_Mortise | |||
| III.5.60 | ISSC Item III.5.60 (Access Control Only Entry-Standard) HID FIPS 201_No Panel_ACS_Mortise | |||
| III.6.30 | ISSC Item III.6.30 (Access Control Only Entry-Expedited) HID FIPS 201_No Panel_ACS_ No Lock | |||
| III.6.60 | ISSC Item III.6.60 (Access Control Only Entry-Standard) HID FIPS 201_No Panel_ACS_No Lock | |||
| IV. Egress Door: | ||||
| IV.1.30 | ISSC Item IV.1.30 (Egress Door)- Expedited | |||
| IV.1.60 | ISSC Item IV.1.60 (Egress Door) - Standard | |||
| DRS-OPR-65-05 | ||||
| V. Additional Devices: | ||||
| These devices below are strictly for adding to packages, I‐III above. | ||||
| V.1.30 | ISSC Item V.1.30 (Additional PIR) - Expedited | |||
| V.1.60 | ISSC Item V.1.60 (Additional PIR) - Standard | |||
| V.2.30 | ISSC Item V.2.30 (Additional Duress) - Expedited | |||
| V.2.60 | ISSC Item V.2.60 (Additional Duress) - Standard | |||
| V.3.30 | ISSC Item V.3.30 (Additional IDRS) - Expedited | |||
| V.3.60 | ISSC Item V.3.60 (Additional IDRS) - Standard | |||
| V.4.30 | ISSC Item V.4.30 (Additional IDRS Button) - Expedited | |||
| V.4.60 | ISSC Item V.4.60 (Additional IDRS Button) - Standard | |||
| V.5.30 | ISSC Item V.5.30 (Additional IDRS Piezo) - Expedited | |||
| V.5.60 | ISSC Item V.5.60 (Additional IDRS Piezo) - Standard | |||
| V.6.30 | ISSC Item V.6.30 (Additional Mortise lock) - Expedited | |||
| V.6.60 | ISSC Item V.6.60 (Additional Mortise lock) - Standard | |||
| V.7.30 | ISSC Item V.7.30 (Additional BMS) - Expedited | |||
| V.7.60 | ISSC Item V.7.60 (Additional BMS) - Standard | |||
| V.8.30 | ISSC Item V.8.30 (Additional Glass Break) - Expedited | |||
| V.8.60 | ISSC Item V.8.60 (Additional Glass Break) - Standard | |||
| V.9.30 | ISSC Item V.9.30 (Additional Aiphone Door Video Unit) - Expedited | |||
| V.9.60 | ISSC Item V.9.60 (Additional Aiphone Door Video Unit) - Standard | |||
| V.10.30 | ISSC Item V.10.30 (Additional Aiphone Sub - Desk Unit) - Expedited | |||
| V.10.60 | ISSC Item V.10.60 (Additional Aiphone Sub - Desk Unit) - Standard | |||
| V.11.30 | ISSC Item V.11.30 (Additional M2100 DCU & IO Boards) | |||
| V.12.30 | ISSC Item V.12.30 (Additional M2150 DC & IO Boards) | |||
| VI. AMAG M2100 /M2150 Alarm Control Panel Accessories: | ||||
| VI.1.30 | ISSC Item VI.1.30 (Additional M2100 DCU & IO Boards to Existing Panel) | |||
| VI.2.30 | ISSC Item VI.2.30 (Additional M2150 DC & IO Boards) - Expedited | |||
| DRS-OPR-65-05 | ||||
| VII. New Installation of Devices to existing panels: | ||||
| VII.1.30 | ISSC Item VII.1.30 (New Individual PIR) - Expedited | |||
| VII.1.60 | ISSC Item VII.1.60 (New Individual PIR) - Standard | |||
| VII.2.30 | ISSC Item VII.2.30 (New Individual BMS) - Expedited | |||
| VII.2.60 | ISSC Item VII.2.60 (New Individual BMS) – Standard | |||
| VII.3.30 | ISSC Item VII.3.30 (New Individual Glass Break) - Expedited | |||
| VII.3.60 | ISSC Item VII.3.60 (New Individual Glass Break) - Standard | |||
| VII.4.30 | ISSC Item VII.4.30 (New Electric Strike) - Expedited | |||
| VII.4.60 | ISSC Item VII.4.60 (New Electric Strike) - Standard | |||
| VII.5.35 | ISSC Item VII.5.35 (New Duress Button) | |||
| VII.6.35 | ISSC Item VII.6.35 (New IDRS) | |||
| VII.7.35 | ISSC Item VII.7.35 (New IDRS Button) | |||
| VII.8.35 | ISSC Item VII.8.35 (New IDRS Piezo) | |||
| VII.9.30 | ISSC Item VII.9.30 (Aiphone Door Video System w/ Desk Master Unit) - Expedited | |||
| VII.9.60 | ISSC Item VII.9.60 (Aiphone Door Video System w/ Desk Master Unit) - Standard | |||
| VII.10.30 | ISSC Item VII.10.30 (New Aiphone Door Video Unit to Existing System) - Expedited | |||
| VII.10.60 | ISSC Item VII.10.60 (New Aiphone Door Video Unit to Existing System) - Standard | |||
| VII.11.30 | ISSC Item VII.11.30 (Additional Aiphone Sub Desk Unit to Existing System)-Expedited | |||
| VII.11.60 | ISSC Item VII.11.60 (Additional Aiphone Sub Desk Unit to Existing System) - Standard | |||
| VII.12.30 | ISSC Item VII.12.30 New Door Box Device Rough In) | |||
| VIII. Miscellaneous Items | ||||
| VIII.1.30 | ISSC Item VIII.1.30 (Decommissioning One Zone or Subzone) Removal of all Equipment from zone | |||
| VIII.2.30 | ISSC Item VIII.2.30 (Relocate One IDRS Button) | |||
| IX. Permits | ||||
| IX.1.30 | ISSC Item IX.1.30 (Building Permit) 1st Floor with the first door locking device | |||
| DRS-OPR-65-05 | ||||
| IX.2.30 | ISSC Item IX.2.30 (Building and Low Voltage Permit) 1st Floor, First Door Locking Device, 1st group of 4-devices, & wiring. | |||
| IX.3.30 | ISSC Item IX.3.30 (Low Voltage Permit) 1st group of 4-devices & wiring. | |||
| IX.4.30 | ISSC Item IX.4.30 (Low Voltage Permit-Each Additional 4-Devices over base permit) 4-devices & wiring. | |||
| IX.5.30 | ISSC Item IX.5.30 (Building Permit-Each Additional Locking Door) $69.75 | |||
| TOTAL | ||||
| Multiply the total by 10 for evaluation purposes. | x10 | x10 | ||
| Subtotal | ||||
| Add $2 Million for non-priced items | $ 2,000,000.00 | $ 2,000,000.00 | ||
| Grand Total | ||||
| Note 1: The Price List will be reviewed annually before the option is exercised and revised as necessary by mutual agreement. | ||||
| Note 2: Additional Devices and New Installation of Devices shall be compatible with the existing AMAG systems. | ||||
| GOVERNMENT PROVIDED ITEMS | ||||
| 2. The Government will provide necessary power and connectivity that will be installed within three feet of the devices that is represented in the system requirements matrix. | ||||
| 3. If a magnetic lock is requested the Government will provide an independent fire alarm dry contact relay within three feet of the AMAG alarm control panel. | ||||
| 4. All door hardware, doors, and frames will be provided by the Government. | ||||
| 5. The Government will provide necessary AMAG servers and software as the current limitation is 64 panels/nodes per communications client server. |
Option Year 2
| OPTION YEAR 2 - PRICE LIST AND SCOPE OF WORK | ||||
| DESCRIPTION | POP CALENDAR DAYS | LEASED FACILITY PRICE | PENTAGON PRICE | |
| Item No. | I. Main Entry Zone Packages: | |||
| I.1.30 | Item I.1.30 (Main Entry-Expedited): Install one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) AMAG exterior reader, (1) AMAG interior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch. Complete in 30 days | |||
| I.1.60 | Item I.1.60 (Main Entry-Standard) Install one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) AMAG exterior reader, (1) AMAG interior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch. Complete in 60 days | |||
| I.2.30 | ISSC Item I.2.30 (Main Entry-Expedited) AMAG FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.2.60 | ISSC Item I.2.60 (Main Entry-Standard) AMAG FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.3.30 | ISSC Item I.3.30 (Main Entry-Expedited) AMAG FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.3.60 | ISSC Item I.3.60 (Main Entry-Standard) AMAG FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.4.30 | ISSC Item I.4.30 (Main Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_ No Lock | |||
| I.4.60 | ISSC Item I.4.60 (Main Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_No Lock | |||
| I.5.30 | ISSC Item I.5.30 (Main Entry-Expedited) HID FIPS 201_Panel_ACS_IDS_Electric Strike | |||
| I.5.60 | ISSC Item I.5.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_Electric Strike | |||
| I.6.30 | ISSC Item I.6.30 (Main Entry-Expedited) HID FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.6.60 | ISSC Item I.6.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.7.30 | ISSC Item I.7.30 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.7.60 | ISSC Item I.7.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.8.30 | ISSC Item I.8.30 (Main Entry): HID FIPS 201 Reader-ACS IDS-NO lock or panel | |||
| I.8.60 | ISSC Item I.8.60 (Main Entry): HID FIPS 201 Reader-No Panel-ACSIDS- No Lock | |||
| II. Secondary Zone Packages: | ||||
| II.1.30 | ISSC Item II.1.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.1.60 | ISSC Item II.1.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.2.30 | ISSC Item II.2.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.2.60 | ISSC Item II.2.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.3.30 | ISSC Item II.3.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_ No Lock | |||
| II.3.60 | ISSC Item II.3.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_No Lock | |||
| II.4.30 | ISSC Item II.4.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.4.60 | ISSC Item II.4.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.5.30 | ISSC Item II.5.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.5.60 | ISSC Item II.5.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.6.30 | ISSC Item II.6.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_ No Lock | |||
| II.6.60 | ISSC Item II.6.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_No Lock | |||
| III. Access Control Only Packages: | ||||
| III.1.30 | ISSC Item III.1.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_ES | |||
| III.1.60 | ISSC Item III.1.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_ES | |||
| III.2.30 | ISSC Item III.2.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_Mortise | |||
| III.2.60 | ISSC Item III.2.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_Mortise | |||
| III.3.30 | ISSC Item III.3.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_ No Lock | |||
| III.3.60 | ISSC Item III.3.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_No Lock | |||
| III.4.30 | ISSC Item III.4.30 (Access Control Only Entry-Expedited) HID FIPS 201_No Panel_ACS_ES | |||
| III.4.60 | ISSC Item III.4.60 (Access Control Only Entry-Standard) HID FIPS 201_No Panel_ACS_ES | |||
| III.5.30 | ISSC Item III.5.30 (Access Control Only Entry-Expedited) HID FIPS 201_No Panel_ACS_Mortise | |||
| III.5.60 | ISSC Item III.5.60 (Access Control Only Entry-Standard) HID FIPS 201_No Panel_ACS_Mortise | |||
| III.6.30 | ISSC Item III.6.30 (Access Control Only Entry-Expedited) HID FIPS 201_No Panel_ACS_ No Lock | |||
| III.6.60 | ISSC Item III.6.60 (Access Control Only Entry-Standard) HID FIPS 201_No Panel_ACS_No Lock | |||
| IV. Egress Door: | ||||
| IV.1.30 | ISSC Item IV.1.30 (Egress Door)- Expedited | |||
| IV.1.60 | ISSC Item IV.1.60 (Egress Door) - Standard | |||
| DRS-OPR-65-05 | ||||
| V. Additional Devices: | ||||
| These devices below are strictly for adding to packages, I‐III above. | ||||
| V.1.30 | ISSC Item V.1.30 (Additional PIR) - Expedited | |||
| V.1.60 | ISSC Item V.1.60 (Additional PIR) - Standard | |||
| V.2.30 | ISSC Item V.2.30 (Additional Duress) - Expedited | |||
| V.2.60 | ISSC Item V.2.60 (Additional Duress) - Standard | |||
| V.3.30 | ISSC Item V.3.30 (Additional IDRS) - Expedited | |||
| V.3.60 | ISSC Item V.3.60 (Additional IDRS) - Standard | |||
| V.4.30 | ISSC Item V.4.30 (Additional IDRS Button) - Expedited | |||
| V.4.60 | ISSC Item V.4.60 (Additional IDRS Button) - Standard | |||
| V.5.30 | ISSC Item V.5.30 (Additional IDRS Piezo) - Expedited | |||
| V.5.60 | ISSC Item V.5.60 (Additional IDRS Piezo) - Standard | |||
| V.6.30 | ISSC Item V.6.30 (Additional Mortise lock) - Expedited | |||
| V.6.60 | ISSC Item V.6.60 (Additional Mortise lock) - Standard | |||
| V.7.30 | ISSC Item V.7.30 (Additional BMS) - Expedited | |||
| V.7.60 | ISSC Item V.7.60 (Additional BMS) - Standard | |||
| V.8.30 | ISSC Item V.8.30 (Additional Glass Break) - Expedited | |||
| V.8.60 | ISSC Item V.8.60 (Additional Glass Break) - Standard | |||
| V.9.30 | ISSC Item V.9.30 (Additional Aiphone Door Video Unit) - Expedited | |||
| V.9.60 | ISSC Item V.9.60 (Additional Aiphone Door Video Unit) - Standard | |||
| V.10.30 | ISSC Item V.10.30 (Additional Aiphone Sub - Desk Unit) - Expedited | |||
| V.10.60 | ISSC Item V.10.60 (Additional Aiphone Sub - Desk Unit) - Standard | |||
| V.11.30 | ISSC Item V.11.30 (Additional M2100 DCU & IO Boards) | |||
| V.12.30 | ISSC Item V.12.30 (Additional M2150 DC & IO Boards) | |||
| VI. AMAG M2100 /M2150 Alarm Control Panel Accessories: | ||||
| VI.1.30 | ISSC Item VI.1.30 (Additional M2100 DCU & IO Boards to Existing Panel) | |||
| VI.2.30 | ISSC Item VI.2.30 (Additional M2150 DC & IO Boards) - Expedited | |||
| DRS-OPR-65-05 | ||||
| VII. New Installation of Devices to existing panels: | ||||
| VII.1.30 | ISSC Item VII.1.30 (New Individual PIR) - Expedited | |||
| VII.1.60 | ISSC Item VII.1.60 (New Individual PIR) - Standard | |||
| VII.2.30 | ISSC Item VII.2.30 (New Individual BMS) - Expedited | |||
| VII.2.60 | ISSC Item VII.2.60 (New Individual BMS) – Standard | |||
| VII.3.30 | ISSC Item VII.3.30 (New Individual Glass Break) - Expedited | |||
| VII.3.60 | ISSC Item VII.3.60 (New Individual Glass Break) - Standard | |||
| VII.4.30 | ISSC Item VII.4.30 (New Electric Strike) - Expedited | |||
| VII.4.60 | ISSC Item VII.4.60 (New Electric Strike) - Standard | |||
| VII.5.35 | ISSC Item VII.5.35 (New Duress Button) | |||
| VII.6.35 | ISSC Item VII.6.35 (New IDRS) | |||
| VII.7.35 | ISSC Item VII.7.35 (New IDRS Button) | |||
| VII.8.35 | ISSC Item VII.8.35 (New IDRS Piezo) | |||
| VII.9.30 | ISSC Item VII.9.30 (Aiphone Door Video System w/ Desk Master Unit) - Expedited | |||
| VII.9.60 | ISSC Item VII.9.60 (Aiphone Door Video System w/ Desk Master Unit) - Standard | |||
| VII.10.30 | ISSC Item VII.10.30 (New Aiphone Door Video Unit to Existing System) - Expedited | |||
| VII.10.60 | ISSC Item VII.10.60 (New Aiphone Door Video Unit to Existing System) - Standard | |||
| VII.11.30 | ISSC Item VII.11.30 (Additional Aiphone Sub Desk Unit to Existing System)-Expedited | |||
| VII.11.60 | ISSC Item VII.11.60 (Additional Aiphone Sub Desk Unit to Existing System) - Standard | |||
| VII.12.30 | ISSC Item VII.12.30 New Door Box Device Rough In) | |||
| VIII. Miscellaneous Items | ||||
| VIII.1.30 | ISSC Item VIII.1.30 (Decommissioning One Zone or Subzone) Removal of all Equipment from zone | |||
| VIII.2.30 | ISSC Item VIII.2.30 (Relocate One IDRS Button) | |||
| IX. Permits | ||||
| IX.1.30 | ISSC Item IX.1.30 (Building Permit) 1st Floor with the first door locking device | |||
| DRS-OPR-65-05 | ||||
| IX.2.30 | ISSC Item IX.2.30 (Building and Low Voltage Permit) 1st Floor, First Door Locking Device, 1st group of 4-devices, & wiring. | |||
| IX.3.30 | ISSC Item IX.3.30 (Low Voltage Permit) 1st group of 4-devices & wiring. | |||
| IX.4.30 | ISSC Item IX.4.30 (Low Voltage Permit-Each Additional 4-Devices over base permit) 4-devices & wiring. | |||
| IX.5.30 | ISSC Item IX.5.30 (Building Permit-Each Additional Locking Door) $69.75 | |||
| TOTAL | ||||
| Multiply the total by 10 for evaluation purposes. | x10 | x10 | ||
| Subtotal | ||||
| Add $2 Million for non-priced items | $ 2,000,000.00 | $ 2,000,000.00 | ||
| Grand Total | ||||
| Note 1: The Price List will be reviewed annually before the option is exercised and revised as necessary by mutual agreement. | ||||
| Note 2: Additional Devices and New Installation of Devices shall be compatible with the existing AMAG systems. | ||||
| GOVERNMENT PROVIDED ITEMS | ||||
| 2. The Government will provide necessary power and connectivity that will be installed within three feet of the devices that is represented in the system requirements matrix. | ||||
| 3. If a magnetic lock is requested the Government will provide an independent fire alarm dry contact relay within three feet of the AMAG alarm control panel. | ||||
| 4. All door hardware, doors, and frames will be provided by the Government. | ||||
| 5. The Government will provide necessary AMAG servers and software as the current limitation is 64 panels/nodes per communications client server. |
Option Year 3
| OPTION YEAR 3 - PRICE LIST AND SCOPE OF WORK | ||||
| DESCRIPTION | POP CALENDAR DAYS | LEASED FACILITY PRICE | PENTAGON PRICE | |
| Item No. | I. Main Entry Zone Packages: | |||
| I.1.30 | Item I.1.30 (Main Entry-Expedited): Install one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) AMAG exterior reader, (1) AMAG interior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch. Complete in 30 days | |||
| I.1.60 | Item I.1.60 (Main Entry-Standard) Install one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) AMAG exterior reader, (1) AMAG interior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch. Complete in 60 days | |||
| I.2.30 | ISSC Item I.2.30 (Main Entry-Expedited) AMAG FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.2.60 | ISSC Item I.2.60 (Main Entry-Standard) AMAG FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.3.30 | ISSC Item I.3.30 (Main Entry-Expedited) AMAG FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.3.60 | ISSC Item I.3.60 (Main Entry-Standard) AMAG FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.4.30 | ISSC Item I.4.30 (Main Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_ No Lock | |||
| I.4.60 | ISSC Item I.4.60 (Main Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_No Lock | |||
| I.5.30 | ISSC Item I.5.30 (Main Entry-Expedited) HID FIPS 201_Panel_ACS_IDS_Electric Strike | |||
| I.5.60 | ISSC Item I.5.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_Electric Strike | |||
| I.6.30 | ISSC Item I.6.30 (Main Entry-Expedited) HID FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.6.60 | ISSC Item I.6.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.7.30 | ISSC Item I.7.30 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.7.60 | ISSC Item I.7.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.8.30 | ISSC Item I.8.30 (Main Entry): HID FIPS 201 Reader-ACS IDS-NO lock or panel | |||
| I.8.60 | ISSC Item I.8.60 (Main Entry): HID FIPS 201 Reader-No Panel-ACSIDS- No Lock | |||
| II. Secondary Zone Packages: | ||||
| II.1.30 | ISSC Item II.1.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.1.60 | ISSC Item II.1.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.2.30 | ISSC Item II.2.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.2.60 | ISSC Item II.2.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.3.30 | ISSC Item II.3.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_ No Lock | |||
| II.3.60 | ISSC Item II.3.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_No Lock | |||
| II.4.30 | ISSC Item II.4.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.4.60 | ISSC Item II.4.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.5.30 | ISSC Item II.5.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.5.60 | ISSC Item II.5.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.6.30 | ISSC Item II.6.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_ No Lock | |||
| II.6.60 | ISSC Item II.6.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_No Lock | |||
| III. Access Control Only Packages: | ||||
| III.1.30 | ISSC Item III.1.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_ES | |||
| III.1.60 | ISSC Item III.1.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_ES | |||
| III.2.30 | ISSC Item III.2.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_Mortise | |||
| III.2.60 | ISSC Item III.2.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_Mortise | |||
| III.3.30 | ISSC Item III.3.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_ No Lock | |||
| III.3.60 | ISSC Item III.3.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_No Lock | |||
| III.4.30 | ISSC Item III.4.30 (Access Control Only Entry-Expedited) HID FIPS 201_No Panel_ACS_ES | |||
| III.4.60 | ISSC Item III.4.60 (Access Control Only Entry-Standard) HID FIPS 201_No Panel_ACS_ES | |||
| III.5.30 | ISSC Item III.5.30 (Access Control Only Entry-Expedited) HID FIPS 201_No Panel_ACS_Mortise | |||
| III.5.60 | ISSC Item III.5.60 (Access Control Only Entry-Standard) HID FIPS 201_No Panel_ACS_Mortise | |||
| III.6.30 | ISSC Item III.6.30 (Access Control Only Entry-Expedited) HID FIPS 201_No Panel_ACS_ No Lock | |||
| III.6.60 | ISSC Item III.6.60 (Access Control Only Entry-Standard) HID FIPS 201_No Panel_ACS_No Lock | |||
| IV. Egress Door: | ||||
| IV.1.30 | ISSC Item IV.1.30 (Egress Door)- Expedited | |||
| IV.1.60 | ISSC Item IV.1.60 (Egress Door) - Standard | |||
| DRS-OPR-65-05 | ||||
| V. Additional Devices: | ||||
| These devices below are strictly for adding to packages, I‐III above. | ||||
| V.1.30 | ISSC Item V.1.30 (Additional PIR) - Expedited | |||
| V.1.60 | ISSC Item V.1.60 (Additional PIR) - Standard | |||
| V.2.30 | ISSC Item V.2.30 (Additional Duress) - Expedited | |||
| V.2.60 | ISSC Item V.2.60 (Additional Duress) - Standard | |||
| V.3.30 | ISSC Item V.3.30 (Additional IDRS) - Expedited | |||
| V.3.60 | ISSC Item V.3.60 (Additional IDRS) - Standard | |||
| V.4.30 | ISSC Item V.4.30 (Additional IDRS Button) - Expedited | |||
| V.4.60 | ISSC Item V.4.60 (Additional IDRS Button) - Standard | |||
| V.5.30 | ISSC Item V.5.30 (Additional IDRS Piezo) - Expedited | |||
| V.5.60 | ISSC Item V.5.60 (Additional IDRS Piezo) - Standard | |||
| V.6.30 | ISSC Item V.6.30 (Additional Mortise lock) - Expedited | |||
| V.6.60 | ISSC Item V.6.60 (Additional Mortise lock) - Standard | |||
| V.7.30 | ISSC Item V.7.30 (Additional BMS) - Expedited | |||
| V.7.60 | ISSC Item V.7.60 (Additional BMS) - Standard | |||
| V.8.30 | ISSC Item V.8.30 (Additional Glass Break) - Expedited | |||
| V.8.60 | ISSC Item V.8.60 (Additional Glass Break) - Standard | |||
| V.9.30 | ISSC Item V.9.30 (Additional Aiphone Door Video Unit) - Expedited | |||
| V.9.60 | ISSC Item V.9.60 (Additional Aiphone Door Video Unit) - Standard | |||
| V.10.30 | ISSC Item V.10.30 (Additional Aiphone Sub - Desk Unit) - Expedited | |||
| V.10.60 | ISSC Item V.10.60 (Additional Aiphone Sub - Desk Unit) - Standard | |||
| V.11.30 | ISSC Item V.11.30 (Additional M2100 DCU & IO Boards) | |||
| V.12.30 | ISSC Item V.12.30 (Additional M2150 DC & IO Boards) | |||
| VI. AMAG M2100 /M2150 Alarm Control Panel Accessories: | ||||
| VI.1.30 | ISSC Item VI.1.30 (Additional M2100 DCU & IO Boards to Existing Panel) | |||
| VI.2.30 | ISSC Item VI.2.30 (Additional M2150 DC & IO Boards) - Expedited | |||
| DRS-OPR-65-05 | ||||
| VII. New Installation of Devices to existing panels: | ||||
| VII.1.30 | ISSC Item VII.1.30 (New Individual PIR) - Expedited | |||
| VII.1.60 | ISSC Item VII.1.60 (New Individual PIR) - Standard | |||
| VII.2.30 | ISSC Item VII.2.30 (New Individual BMS) - Expedited | |||
| VII.2.60 | ISSC Item VII.2.60 (New Individual BMS) – Standard | |||
| VII.3.30 | ISSC Item VII.3.30 (New Individual Glass Break) - Expedited | |||
| VII.3.60 | ISSC Item VII.3.60 (New Individual Glass Break) - Standard | |||
| VII.4.30 | ISSC Item VII.4.30 (New Electric Strike) - Expedited | |||
| VII.4.60 | ISSC Item VII.4.60 (New Electric Strike) - Standard | |||
| VII.5.35 | ISSC Item VII.5.35 (New Duress Button) | |||
| VII.6.35 | ISSC Item VII.6.35 (New IDRS) | |||
| VII.7.35 | ISSC Item VII.7.35 (New IDRS Button) | |||
| VII.8.35 | ISSC Item VII.8.35 (New IDRS Piezo) | |||
| VII.9.30 | ISSC Item VII.9.30 (Aiphone Door Video System w/ Desk Master Unit) - Expedited | |||
| VII.9.60 | ISSC Item VII.9.60 (Aiphone Door Video System w/ Desk Master Unit) - Standard | |||
| VII.10.30 | ISSC Item VII.10.30 (New Aiphone Door Video Unit to Existing System) - Expedited | |||
| VII.10.60 | ISSC Item VII.10.60 (New Aiphone Door Video Unit to Existing System) - Standard | |||
| VII.11.30 | ISSC Item VII.11.30 (Additional Aiphone Sub Desk Unit to Existing System)-Expedited | |||
| VII.11.60 | ISSC Item VII.11.60 (Additional Aiphone Sub Desk Unit to Existing System) - Standard | |||
| VII.12.30 | ISSC Item VII.12.30 New Door Box Device Rough In) | |||
| VIII. Miscellaneous Items | ||||
| VIII.1.30 | ISSC Item VIII.1.30 (Decommissioning One Zone or Subzone) Removal of all Equipment from zone | |||
| VIII.2.30 | ISSC Item VIII.2.30 (Relocate One IDRS Button) | |||
| IX. Permits | ||||
| IX.1.30 | ISSC Item IX.1.30 (Building Permit) 1st Floor with the first door locking device | |||
| DRS-OPR-65-05 | ||||
| IX.2.30 | ISSC Item IX.2.30 (Building and Low Voltage Permit) 1st Floor, First Door Locking Device, 1st group of 4-devices, & wiring. | |||
| IX.3.30 | ISSC Item IX.3.30 (Low Voltage Permit) 1st group of 4-devices & wiring. | |||
| IX.4.30 | ISSC Item IX.4.30 (Low Voltage Permit-Each Additional 4-Devices over base permit) 4-devices & wiring. | |||
| IX.5.30 | ISSC Item IX.5.30 (Building Permit-Each Additional Locking Door) $69.75 | |||
| TOTAL | ||||
| Multiply the total by 10 for evaluation purposes. | x10 | x10 | ||
| Subtotal | ||||
| Add $2 Million for non-priced items | $ 2,000,000.00 | $ 2,000,000.00 | ||
| Grand Total | ||||
| Note 1: The Price List will be reviewed annually before the option is exercised and revised as necessary by mutual agreement. | ||||
| Note 2: Additional Devices and New Installation of Devices shall be compatible with the existing AMAG systems. | ||||
| GOVERNMENT PROVIDED ITEMS | ||||
| 2. The Government will provide necessary power and connectivity that will be installed within three feet of the devices that is represented in the system requirements matrix. | ||||
| 3. If a magnetic lock is requested the Government will provide an independent fire alarm dry contact relay within three feet of the AMAG alarm control panel. | ||||
| 4. All door hardware, doors, and frames will be provided by the Government. | ||||
| 5. The Government will provide necessary AMAG servers and software as the current limitation is 64 panels/nodes per communications client server. |
Option Year 4
| OPTION YEAR 4 - PRICE LIST AND SCOPE OF WORK | ||||
| DESCRIPTION | POP CALENDAR DAYS | LEASED FACILITY PRICE | PENTAGON PRICE | |
| Item No. | I. Main Entry Zone Packages: | |||
| I.1.30 | Item I.1.30 (Main Entry-Expedited): Install one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) AMAG exterior reader, (1) AMAG interior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch. Complete in 30 days | |||
| I.1.60 | Item I.1.60 (Main Entry-Standard) Install one AMAG alarm control panel: (1) DCU board (2) I/O Board, (1) 4-amp power supply, (1) AMAG exterior reader, (1) AMAG interior reader, (1) alarm status indicator, (1) electric strike, (1) request to exit sensor, (1) Infrared motion sensor, and (1) balanced magnetic switch. Complete in 60 days | |||
| I.2.30 | ISSC Item I.2.30 (Main Entry-Expedited) AMAG FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.2.60 | ISSC Item I.2.60 (Main Entry-Standard) AMAG FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.3.30 | ISSC Item I.3.30 (Main Entry-Expedited) AMAG FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.3.60 | ISSC Item I.3.60 (Main Entry-Standard) AMAG FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.4.30 | ISSC Item I.4.30 (Main Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_ No Lock | |||
| I.4.60 | ISSC Item I.4.60 (Main Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_No Lock | |||
| I.5.30 | ISSC Item I.5.30 (Main Entry-Expedited) HID FIPS 201_Panel_ACS_IDS_Electric Strike | |||
| I.5.60 | ISSC Item I.5.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_Electric Strike | |||
| I.6.30 | ISSC Item I.6.30 (Main Entry-Expedited) HID FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.6.60 | ISSC Item I.6.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_Mortise | |||
| I.7.30 | ISSC Item I.7.30 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.7.60 | ISSC Item I.7.60 (Main Entry-Standard) HID FIPS 201_Panel_ACS_IDS_No Lock | |||
| I.8.30 | ISSC Item I.8.30 (Main Entry): HID FIPS 201 Reader-ACS IDS-NO lock or panel | |||
| I.8.60 | ISSC Item I.8.60 (Main Entry): HID FIPS 201 Reader-No Panel-ACSIDS- No Lock | |||
| II. Secondary Zone Packages: | ||||
| II.1.30 | ISSC Item II.1.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.1.60 | ISSC Item II.1.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.2.30 | ISSC Item II.2.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.2.60 | ISSC Item II.2.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.3.30 | ISSC Item II.3.30 (Secondary Entry-Expedited) AMAG FIPS 201_No Panel_ACS_IDS_ No Lock | |||
| II.3.60 | ISSC Item II.3.60 (Secondary Entry-Standard) AMAG FIPS 201_No Panel_ACS_IDS_No Lock | |||
| II.4.30 | ISSC Item II.4.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.4.60 | ISSC Item II.4.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_Electric Strike | |||
| II.5.30 | ISSC Item II.5.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.5.60 | ISSC Item II.5.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_Mortise | |||
| II.6.30 | ISSC Item II.6.30 (Secondary Entry-Expedited) HID FIPS 201_No Panel_ACS_IDS_ No Lock | |||
| II.6.60 | ISSC Item II.6.60 (Secondary Entry-Standard) HID FIPS 201_No Panel_ACS_IDS_No Lock | |||
| III. Access Control Only Packages: | ||||
| III.1.30 | ISSC Item III.1.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_ES | |||
| III.1.60 | ISSC Item III.1.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_ES | |||
| III.2.30 | ISSC Item III.2.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_Mortise | |||
| III.2.60 | ISSC Item III.2.60 (Access Control Only Entry-Standard) AMAG FIPS 201_No Panel_ACS_Mortise | |||
| III.3.30 | ISSC Item III.3.30 (Access Control Only Entry-Expedited) AMAG FIPS 201_No Panel_ACS_ No Lock |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .