Ftm32Dwgs3-28-24Const_(1).pdf
PDF 10 MB Posted
- Attached to
- Legacy Island Phase II
- Solicitation number
- ITB 26-029
- Issued by
- Lee County, Fort Lauderdale City, Florida
About this file
This construction permit plan document was prepared by HWA Inc., marine engineers and environmental consultants, for the City of Fort Myers, Florida, for the Legacy Island Park Development project located on an island in the Caloosahatchee River upstream of the Business 41 bridge. The project encompasses Phase II development including a five-slip docking facility, an overwater observation pier, two 16' x 16' gazebos, and signage. The construction permit plans consist of 18 sheets detailing bathymetric survey data, existing and proposed site plans for both waterfront and upland areas, detailed drawings of the main dock, observation deck, paddlecraft beaches, cross sections, sign plan, erosion control and stabilization measures, and gazebo specifications. The bathymetric survey was completed on January 3, 2019, with site elevations surveyed on May 13, 2019, using NAVD88 as the vertical datum reference. Mean Low Water elevation is -0.89' NAVD88 with Mean High Water at 0.06' NAVD.
The plans are dated March 26, 2024, and have been digitally signed and sealed by Hans J.M. Wilson, a professional engineer. The project is located in Section 12, Township 44 South, Range 24 East, with the site identified near Doctors Pass. The document includes detailed contour mapping showing water depths ranging from -1 to greater than -10 feet referenced to Mean Low Water, along with wetland limits and site-specific elevations. Erosion control and stabilization measures are incorporated into the design to address environmental considerations at the waterfront location.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Location
Project Location
Location MapAerial Location
SCALE: 1" = 1,000'
Note: The scale of these plans may have changed due to reproduction.
Plans Prepared for:
City of Fort Myers PO Box 2217 Fort Myers, FL 33902
1938 Hill Ave. Ft. Myers, Florida 33901 MARINE ENGINEERS and ENVIRONMENTAL CONSULTANTS
Tel: 239-334-6870 Fax: 239-334-7810
PREPARED BY:
Call 48 Hours before you dig in Florida It's the Law
Sunshine State one call of Florida, Inc Drawing Index:
Page: Drawing:
1 Cover Page 2 Bathymetric Survey 3 Existing Site Plan 4 Proposed Site Plan - Waterfront 5 Detail A - Proposed Main Dock 6 Detail B - Proposed Observation Deck 7 Detail C - Paddlecraft Beaches 8 Cross Sections AA & BB 9 Cross Section CC 10 Cross Section DD 11 Cross Section EE & FF 12 Cross Section GG 13 Proposed Site Plan - Upland 14 Detail D - Upland North 15 Detail E - Upland South 16 Proposed Sign Plan 17 Erosion Control and Stabilization 18 Gazebo Detail
LEGACY ISLAND PARK DEVELOPMENT
FORT MYERS
SCALE: 1" = 2,500'
SECTION: 12
TOWNSHIP: 44 S
RANGE: 24 E
DOCTORS PASS
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
AutoCAD SHX Text
CONSTRUCTION PERMIT PLANS
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
522PHOENIX523PHOENIX
535SEAGRAPE
0.828700
WETLIMITS
0.763701WETLIMITS
0.819702
WETLIMITS
6.797706
WETLIMITS
1.090705
WETLIMITS
Scale 1" = 100'
SECTION: 12
TOWNSHIP: 44 S
RANGE: 24 E
Bathymetric Survey SHEET
City of Fort Myers 3-26-24
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Approximate Mean High Water Line.
Notes: Bathymetric survey completed on 1-3-19 by HWA, Inc. Depths reference Mean Low Water (MLW) El = -0.89' NAVD88. Per DEP Tide Station 872-5520.
Mean High Water @ 0.06' NAVD. Site elevations surveyed by HWA on 5-13-19 reference NAVD88.
Contour Legend
-1 to -2 -2 to -3 -3 to -4 -4 to -5 -5 to -6 -6 to -7 -7 to -8 -8 to -9
-9 to -10 >-10
<0 0 to -1
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
2 /18
CALOOSAHATCHEE RIVER
BUSINESS 41 NORTHBOUND
BUSIN
ESS 41 SO
UTHBO
UN
D
Lee County Aerial 2023
AutoCAD SHX Text -8
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -7
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -4
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -1
AutoCAD SHX Text -1
AutoCAD SHX Text -1
AutoCAD SHX Text -1
AutoCAD SHX Text -1
AutoCAD SHX Text -3
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
CONSTRUCTION PERMIT PLANS
0.828
WETLIMITS
0.763
WETLIMITS
0.819
WETLIMITS
6.797
WETLIMITS
+2
+2
+2
+2
+2
+2 +1
+1
+1
+1
+1 +1
+1
+3 +3+4
+2
1.090
WETLIMITS
+2
+1
+1
+1
SECTION: 12
TOWNSHIP: 44 S
RANGE: 24 E
SHEET
City of Fort Myers
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Existing Site Plan
SCALE: 1" = 60'
Approximate Mean High Water Line (0.06' NAVD).
Existing wetland.
Note: Topographic Survey complete by HWA, Inc. on 5-13-19.
Elevations reference NAVD88, Mean High Water @ +0.06' NAVD.
Zoning - Vacant Governmental /80
3-26-24
/18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Lee County Aerial 2023
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
8-7-2020
SECTION: 12
TOWNSHIP: 44 S
RANGE: 24 E
SHEET
City of Fort Myers
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Proposed Site Plan - Waterfront
SCALE: 1" = 60'
Proposed 5' wide by 180' long access pier.(4) Proposed mooring slips
15' wide by 40' long.
Proposed 10' wide by 20' long observation platform with 4' wide x 80' long access pier.
Proposed 130' living shoreline planted with mangroves to act as wave/wind protection for kayak/canoe landing beach.
Mean high water line.
Proposed 5' wide by 65' long terminal platform
Proposed 493' long by 20' wide rip rap revetment.
Proposed 91' long by 20' wide rip rap/ RCP/stabilization.
Proposed sand beach augmentation.
Sand beach augmentation.
Proposed 130' living shoreline planted with mangroves to act as wave/wind protection for beach.
D
ET
AI
L
A
DETAIL C
DETA
IL
B
Dedicated emergency vessel mooring, 13' wide by 36' long.
4 /18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
3-26-24
Proposed 239' long by 20' wide rip rap revetment.
Lee County Aerial 2023
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
TOWNSHIP: 44 S
RANGE: 24 E
SHEET
City of Fort Myers
CRY
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Detail A - Proposed Main Dock
SCALE: 1" = 20'
Proposed 5' wide by 180' long (900 sf.) access pier, deck elevation 5' above MHW.
(4) Proposed mooring slips 15' wide by 40' long.
Proposed16' x 16' entrance gazebo.
Approximate mean high water line.
Proposed 5' wide by 65' long (325 sf.)
terminal platform, deck elevation 3' above
MHW.
Clear 22,947 sf.
(0.53 ac.) invasive exotics from interior of island.
Proposed 6' wide improved foot trails.
A
A
BB
Proposed 20' wide rip rap stabilization.
DD
(12) Proposed 12" dia.
mooring piles (typ.)
Slip
Slip
E
E
Slip
Slip
Place 85 cy. clean Ortona sand to amend sandy beach.
180'
5'
5'
65'
Note: Bathymetric Survey complete by HWA, Inc. on 1-3-19. Elevations reference mean low water per DEP Tidal Station 872-5520.
Dedicated 13' wide x 36' long vessel mooring (temporary).
5 /18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
GG
3-23-24
Slip
Proposed Dock @ 1,225 sf.
Proposed Mooring Pilings @ 12.
Proposed cross bracing (7 bents on access & 4 bents on the terminal / finger pier)
Handrail, 110' each side.
Lee County Aerial 2023
Ramp down @ 20:1Ramp up @ 20:1
AutoCAD SHX Text -6
AutoCAD SHX Text -6
AutoCAD SHX Text -5
AutoCAD SHX Text -5
AutoCAD SHX Text -4
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -2
AutoCAD SHX Text -1
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
RANGE: 24 E
SHEET
City of Fort Myers
CRY
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Detail B - Proposed Pier
SCALE: 1" = 10'
Proposed 4' wide by 80' long access pier, deck elevation 5' above MHW.
Proposed 10' wide by 20' long observation platform, deck elevation 5' above MHW.
Approximate mean high water line.
Proposed 6' wide foot trails.
Clear 22,947 sf.
(0.53 ac.) invasive exotics from interior of island.
A
A
CCFF
Proposed 20' wide rip rap stabilization.
Proposed 20' wide rip rap stabilization.
10'
20'
4'
80'
6'
Note: Bathymetric Survey complete by HWA, Inc. on 1-3-19. Elevations reference mean low water per DEP Tidal Station 872-5520.
6 /18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
GG
3-23-24
Proposed handrail both sides of access and around the terminal platform (215lf total)
Proposed cross bracing (3 bents on access & across the waterward face of the terminal platform
Lee County Aerial 2023
30' ramp down @ 12:1
AutoCAD SHX Text -2
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
AutoCAD SHX Text %%ODavid E. McKee
AutoCAD SHX Text
REGISTERED PROFESSIONAL ENGINEER
AutoCAD SHX Text
FLORIDA REGISTRATION NO. 38347
AutoCAD SHX Text
DATE:____________________
AutoCAD SHX Text
CA. LIC. NO. 8519
RANGE: 24 E
SHEET
City of Fort Myers
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Detail C- Paddlecraft Beaches
SCALE: 1" = 20'
Proposed RCP planted with red mangrove seedlings to create habitat and protect beach landing area.
Approximate mean high waterline.
Proposed 6' wide foot trail.
Proposed 20' wide rip rap stabilization.
Place 62 cy. of clean Ortona sand for paddle craft landing.
Place 48 cy. of clean Ortona sand for recreational beach area.
Proposed Reef Balls.
Proposed 20' wide rip rap stabilization.
E E20'
Note: Bathymetric Survey complete by HWA, Inc. on 1-3-19. Elevations reference mean low water per DEP Tidal Station 872-5520.
Proposed 16' x 16' gazebo.
7 /18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
G
G
3-26-24
Lee County Aerial 2023
AutoCAD SHX Text -5
AutoCAD SHX Text -4
AutoCAD SHX Text -3
AutoCAD SHX Text -3
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -2
AutoCAD SHX Text -1
AutoCAD SHX Text -1
AutoCAD SHX Text -3
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
AutoCAD SHX Text %%ODavid E. McKee
AutoCAD SHX Text
REGISTERED PROFESSIONAL ENGINEER
AutoCAD SHX Text
FLORIDA REGISTRATION NO. 38347
AutoCAD SHX Text
DATE:____________________
AutoCAD SHX Text
CA. LIC. NO. 8519
RANGE: 24 E
Cross Sections
SHEET
City of Fort Myers
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Cross Section A-A
SCALE: 1" = 2'
Note: Bathymetric Survey complete by HWA, Inc. on 1-3-19.
Elevations reference mean low water per DEP Tidal Station 872-5520.
Cross Section B-B
SCALE: 1" = 8'
Proposed 3" x 10" double cap boards with (2) 5/8" dia. thru bolts, per pile and chamfered, not to extend past outer alignment of piles.
5'
Existing grade, varies.
MLW @ -0.89' NAVD
MHW @ 0.06' NAVD
MLW @ -0.89' NAVD
MHW @ 0.06' NAVD
Proposed 10" dia. wood piling (typ.) with tip penetration minimum of 40% of overall pile length (10' min.) PVC wrapped from one foot above MHW to two feet below mudline, typical.
Proposed 5 8 " dia. thru bolt, countersunk.
5.0' NAVD
3.0' NAVD
Proposed 3" x 8" stringers installed 17" on centers max.
12" Mooring pile w/ pile cap and line hook. Tip penetration minimum of 40% of overall pile length (10' min. ) Typical.
Existing grade.
4.5' Typical
Proposed pile wrap from one foot above MHW to two feet below mudline, typical.
+9.5' NAVD
4.5'
5'15'
20:1
8 /18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Proposed cross bracing, alternating bents.
Proposed cross bracing, alternating bents.
Proposed cross bracing, alternating bents on terminal platform.
3-26-24
Proposed 3" x 8" horizontal boards (3) to allow fire boat to moor/push.
Proposed 2" x 6" composite decking with 1
2 " spacing.
42"
Proposed handrail, typical.
Proposed handrail, typical.
3"
5"
5"
5"
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
AutoCAD SHX Text
CONSTRUCTION PERMIT PLANS
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
RANGE: 24 E
SHEET
City of Fort Myers
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Note: Bathymetric Survey complete by HWA, Inc. on 1-3-19.
Elevations reference mean low water per DEP Tidal Station 872-5520.
Cross Section C-C
SCALE: 1" = 4'
Proposed horizontal 2" x 6" side rail (4) each typical.
MLW @ -0.89' NAVD
MHW @ 0.06' NAVD
Proposed 4" x4" posts, 5' on center.
Proposed horizontal 2" x 6" top rail, angle in @ 30°.
Proposed 3" x 10" double cap boards with
(2) 5/8" dia. thru bolts, per pile and chamfered, not to extend past outer alignment of piles.
Proposed 5 8 " dia.
bolt thru stringer and piling.
5' o.c. typ.
9 /18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Proposed cross bracing, alternating bents.
3-26-24
Proposed 10" dia. wood piling (typ.) with tip penetration minimum of 40% of overall pile length (10' min.) PVC wrapped from one foot above MHW to two feet below mudline, typical.
Proposed 2" x 6" composite decking
5'
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
AutoCAD SHX Text
CONSTRUCTION PERMIT PLANS
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text 0'
AutoCAD SHX Text 2'
4'
PADDLE CRAFT ONLY
TOWNSHIP: 44 S
RANGE: 24 E
SHEET
City of Fort Myers
CRY
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Note: Bathymetric Survey complete by HWA, Inc. on 1-3-19.
Elevations reference mean low water per DEP Tidal Station 872-5520.
Cross Section D-D
SCALE: 1" = 6'
MLW @ -0.89' NAVD
MHW @ 0.06' NAVD
Proposed 3" x 10" double cap boards with (2) 5/8" dia. thru bolts, per pile and chamfered, not to extend past outer alignment of piles.
Proposed 5 8 " dia.
bolt thru stringer and piling.
Proposed amendment of 85 CY of Ortona sand.
Existing grade.
Proposed 16' by 16' gazebo (See Detail) .
Proposed 6" of crushed shell placed on existing grade.
10/18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Proposed RCP with red mangrove seedlings plantedat +1.0' MHW, to create habitat and protect beach landing area.
Proposed Reef balls to create habitat and protect beach landing area.
20:1
3-23-24
Proposed 10" dia. wood piling (typ.) with tip penetration minimum of 40% of overall pile length (10' min.) PVC wrapped from one foot above MHW to two feet below mudline, typical.
No slope on 1st section
NO MOORING
NO MOORING SIGN
MLW
MHW
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
AutoCAD SHX Text
CONSTRUCTION PERMIT PLANS
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text 0'
AutoCAD SHX Text 3'
AutoCAD SHX Text 6'
AutoCAD SHX Text Signs shall be constructed from 0.08 aluminum with engineer grade reflective sheeting, white background with black lettering.
NOT TO SCALE
RANGE: 24 E
Cross Sections
SHEET
City of Fort Myers
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Note: Bathymetric Survey complete by HWA, Inc. on 1-3-19.
Elevations reference mean low water per DEP Tidal Station 872-5520.
Cross Section E-E
Proposed RCP with red mangrove seedlings planted at +1.0' MHW, to create habitat and protect beach landing area.
Existing grade, varies from -1.8' to +1.0' MLW.
Cross Section F-F
SCALE: 1" = 4'
MLW @ -0.89' NAVD
MHW @ 0.06' NAVD
Proposed Bay ball, sand filled 6"-12" .
MLW @ -0.89' NAVD
MHW @ 0.06' NAVD
Proposed handrail with (4) each 2" x 6" side rails and (1) each 2" x 6" top rail.
5' typical
42"
Proposed 3" x 10" double cap boards with (2) 5/8" dia. thru bolts, per pile and chamfered, not to extend past outer alignment of piles.
Proposed 5 8 " dia. bolt thru stringer and pile.
12:1 max slope
Proposed 20' wide rip rap stabilization.
Existing grade.
Proposed 6' wide crushed shell foot trail.
1'
1.5" min.
11/18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Proposed 3" x 10" double cap boards to retain upland ramp crushed shell.
+2.0' NAVD
Average 36" diameter toe boulder.
Min. sand fill 6".
3-26-24
Proposed 10" dia. wood piling (typ.) with tip penetration minimum of 40% of overall pile length (10' min.) PVC wrapped from one foot above MHW to two feet below mudline, typical.
SCALE: 1" = 4'
Add fascia board across end of stringers to contain foot trail fill.
Proposed filter fabric to run up end of pier and beneath fill.
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
AutoCAD SHX Text
CONSTRUCTION PERMIT PLANS
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
RANGE: 24 E
SHEET
City of Fort Myers
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Note: Bathymetric Survey complete by HWA, Inc. on 1-3-19.
Elevations reference mean low water per DEP Tidal Station 872-5520.
Cross Section G-G
SCALE: 1" =4'
MLW @ -0.89' NAVD
MHW @ 0.06' NAVD
12/18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Proposed 20' wide rip rap stabilization.
Average 36" diameter toe boulder, 30% total volume.
Proposed filter fabric.
10' 10'
Mean High Water Line.
Minimum 24" diameter riprap, 50% total volume.
Average 12" diameter riprap, 20% total volume.
2.9' NAVD Minimum top elevation of revetment.
12" minimum tuck or embedment of filter fabric.
12" minimum tuck or embedment of filter fabric.
3-26-24
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
AutoCAD SHX Text
CONSTRUCTION PERMIT PLANS
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
WETLIMITS
0.763
WETLIMITS
0.819
WETLIMITS
6.797
WETLIMITS
1.090
WETLIMITS
SECTION: 12
TOWNSHIP: 44 S
RANGE: 24 E
SHEET
City of Fort Myers
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Proposed Site Plan - Upland
SCALE: 1" = 60'
Proposed 16' x 16' gazebo
Proposed 16' x 16' gazebo
Approximate mean high water line.
Clear 22,947 sf. (0.53 ac.) invasive exotics from interior of island.
Proposed 6' wide x 450' long improved foot trails.
M at ch lin e
DETAIL E
DETAIL D
Lee County Aerial 2023
13/18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
3-27-24
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
0.828700
WETL
IM
ITS
0.763701
WETL
IM
ITS
0.819702
WETL
IM
ITS
6.797706
WETL
IM
ITS
1.090705
WET
LIM
ITS
SECTION: 12
TOWNSHIP: 44 S
RANGE: 24 E
SHEET
City of Fort Myers
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Detail D - Upland North
SCALE: 1" = 20'
Proposed 16' x 16' gazebo (See Detail).
Mean High Water Line.
Clear 22,947 sf.
(0.53 ac.) invasive exotics from interior of island.
Lee County Aerial 2023
Proposed 6' wide foot trails, total 450 linear feet.
Proposed rip rap stabilization.
M at ch lin e
Proposed rip rap stabilization.
Proposed rip rap stabilization.
Proposed future sandy beach.
Proposed future living shoreline.
17' gazebo set back
Existing wetland to remain.
14/18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
3-28-24
Proposed future sandy beach.
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
RANGE: 24 E
SHEET
City of Fort Myers
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Detail E - Upland South
SCALE: 1" = 20'
Proposed16' x 16' entrance gazebo.
Approximate mean high water Line.
Clear 22,947 sf. (0.53 ac.) invasive exotics from interior of island.
Lee County Aerial 2023
Proposed 6' wide improved foot trails, 450 linear feet total.
Proposed future 20' wide rip rap stabilization.
M at ch lin e
Approximate mean high water Line.
Proposed future sandy beach.
Proposed living shoreline.
17.5' gazebo set back
15/18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
3-28-24
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
0.828700
WETL
IM
ITS
0.763701
WETL
IMITS
0.819702
WETL
IMITS
6.797706
WETLIM
ITS
1.090705
WETL
IM
ITS
SECTION: 12
TOWNSHIP: 44 S
RANGE: 24 E
SHEET
City of Fort Myers
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Proposed Sign Plan
SCALE: 1" = 50'
Lee County Aerial 2023
No Fishing Signs, one (1) each side of access, one (1) on T-dock, three (3) total.
No Fishing Signs, one (1) each side mid-dock, one (1) on T-dock, three (3) total.
(1) Save Dolphins, Sea Turtles, Sawfish and Manta Ray Signs at the base of the access pier.
Save Dolphins, Sea Turtles, Sawfish and Manta Ray Sign, one (1) each. Proposed 16' x 16' gazebo
Proposed 16' x 16' gazebo
Proposed observation platform.
No Mooring Signs, one (1) each side of access pier.
(1) Paddle Craft Only, No Motorized Vessels.
Paddle Craft Only
16/18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
3-28-24
Emergency Use Only sign.
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
WETLIMITS
0.763
WETLIMITS
0.819
WETLIMITS
6.797
WETLIMITS
1.090
WETLIMITS
SECTION: 12
TOWNSHIP: 44 S
RANGE: 24 E
SHEET
City of Fort Myers
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Erosion Control and Stabilization
SCALE: 1" = 60'
Proposed observation platform.
Proposed 130' living shoreline.
Approximate mean high water line.
Proposed Main Dock.
Proposed 845' long by 20' wide rip rap stabilization.
Proposed 91' long by 20' wide rip rap stabilization.
Proposed sand beach augmentation.
Sand beach augmentation.
Proposed 130' living shoreline.
Existing wetland, to remain.
Barge with excavator or crane for material transfer, example.
Proposed turbidity screen to be deployed during all work in or over the water.
Proposed silt fence offset 5' from project clearing limits.
Proposed silt fence offset 5' from project clearing limits.
5'
5'
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
3-28-24
17/18
Proposed turbidity curtains to be deployed during all work in or over the water. Curtains to be adjusted along shoreline based on working areas.
AutoCAD SHX Text
FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
RANGE: 24 E
Gazebo Details
SHEET
City of Fort Myers
HJMW
1938 Hill Avenue, Fort Myers, Florida 33901 Office: 239-334-6870 Fax: 239-334-7810 MARINE and ENVIRONMENTAL CONSULTANTS
Gazebo Cross Section
SCALE: 1" = 5'
Gazebo Plan View
SCALE: 1" = 5'
NOTES:
1. THIS DRAWING DOES NOT INTEND
TO SHOW TRUSS QUANTITIES
2. GENERAL CONTRACTOR IS
RESPONSIBLE FOR ALL TEMPORARY
BRACING.
3. IF TRUSS UPLIFT CONDITIONS
EXCEED STRAPPING SPECIFICATIONS,
THE CONTRACTOR MUST NOTIFY THE
DESIGNER PRIOR TO INSTALLATION
OF THE TRUSSES.
3. TRUSSES ARE DESIGNED TO MEET
ALL LOAD INTERACTION, UPLIFT, AND
LATERAL LOAD REQ'S. ALONG W/ THE
INFORMATION PROVIDED ON THIS
DRAWING.
4. CONTRACTOR TO COORDINATE
ALL TEMPORARY BRACING WITH H1B
91 SPECS.
5. PROVIDE GROUP 2 LUMBER FOR
RAFTERS.
CONNECTION SCHEDULE
MARK MANUFACTURER NO. TYPE UPLIFT CAP. NOTES/FASTENERS
NOTE: IF ANY OF THE CONNECTORS SHOWN ARE NOT OBTAINABLE,
IT IS ACCEPTABLE THAT AN EQUAL CONNECTOR IS USED AND HANS
WILSON & ASSOCIATES IS NOTIFIED OF THE CHANGE.
1 SIMPSON LS70 560 10 - 10D NAILS
2 SIMPSON H16S 1470 10 - 10D NAILS
3 SIMPSON HCP1.81 605 6 - 10D NAILS
2 3
# DENOTES TYPICAL CONNECTOR FOR SIMILAR SITUATIONS UNLESS OTHERWISE NOTED
2"X10" HIP JACK RAFTER
2" X 8" COMMON RAFTER
AT 16" ON CENTER
PROVIDE ROOF PITCH OF 6:12
2"X10" FASCIA BOARD
PURLINS NOT SHOWN
4 SIMPSON HRC22 480 6 - 10D NAILS
2"X10" PT WOOD RIDGE BOARD
2"X8" PT WOOD COMMON RAFTER @ 16" ON CENTER
2"X4" PT WOOD PURLINS AT 16" ON CENTER
GALV. RIBBED METAL ROOF SHEATHING
PURLINS TO BE SCREWED TO RAFTERS WITH MIN
4 "X3" ZINC WOOD SCREWS - (2) PER CONNECTION
ROOF DECKING TO BE ATTACHED IN ACCORDANCE TO
SECTION 1507.5 2001 FBC, ASTM A 653 G-90 ZINC COATED
AND INSTALLED PER MANUFACTURERS SPECIFICATIONS
12" PILING BY OTHERS INSTALLED
TO PROVIDE MINIMUM OF
2000 LB UPLIFT RESISTANCE
(2) 5
8 " GALV BOLTS, NUTS AND
WASHERS THRU PILING AND
(2) 2"X12" BEAM. BEAM TO BE
#2 SYP PT AND STAGGERED AT
MID SPAN 24" PILING TO BE
NOTCHED TO ACCEPT
(2) 2"X12" BEAM AS REQUIRED
2"X10" PT WOOD
FASCIA WITH
2" GALV. DRIP EDGE
DESIGN WIND SPEED 160 MPH (3 SEC GUST)
BASIC WIND SPEED 110 MPH
WIND IMPORTANCE FACTOR 1.0
WIND EXPOSURE D
ADJUSTMENT FACTOR
INTERNAL PRESURE COEFFICIENT N/A
COMPONENTS AND CLADDING
INTERIOR ROOF +16.0PSF / -27.0 PSF
EDGE ROOF +16.0 PSF / -53.3 PSF
CORNER ROOF +16.0 / -53.3 PSF
WINDOWS AND DOORS - N/A
16' 16"16"
18/18
This item has been digitally signed and sealed by Hans J.M. Wilson on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
3-28-24
H16S TWIST STRAPS AT
EACH RAFTER TO BEAM
CONNECTION
7'6"
14'
6. Alternative 16' by 16' gazebo, SRP SQUARE 16 by Superior Recreational Products, previously approved by the City of Fort Myers. Design per 2017 FLORIDA BUILDING CODE, 6th Edition, referenced as an attachment.
18"
OVERHANG
AutoCAD SHX Text March 26, 2024 4:20:04 p.m.
AutoCAD SHX Text Drawing: FTM32MASTERCONST.DWG
| Sheets and Views |
| Ftm32MasterConst-1FtmCover Page |
| OLE1 |
| Ftm32MasterConst-2Bathy 11x17 |
| OLE1 |
| Ftm32MasterConst-3FtmExistSitePlan |
| OLE1 |
| Ftm32MasterConst-4FtmProSitePlanWater |
| OLE1 |
| Ftm32MasterConst-5FtmDetail A |
| OLE1 |
| Ftm32MasterConst-6FtmDetail B |
| OLE1 |
| Ftm32MasterConst-7FtmDetail C |
| OLE1 |
| Ftm32MasterConst-8FtmXsect AA-BB |
| OLE1 |
| Ftm32MasterConst-9FtmXsect CC |
| OLE1 |
| Ftm32MasterConst-10FtmXsect DD |
| OLE1 |
| Ftm32MasterConst-11FtmXsectEE-FF 11x17 |
| OLE1 |
| Ftm32MasterConst-12FtmXsect GG |
| OLE1 |
| Ftm32MasterConst-13FtmProSitePlanLand |
| OLE1 |
| Ftm32MasterConst-14FtmDetail D |
| OLE1 |
| Ftm32MasterConst-15FtmDetail E |
| OLE1 |
| Ftm32MasterConst-167Ftm Pro Sign Plan |
| OLE1 |
| Ftm32MasterConst-17FtmErosionControl |
| OLE1 |
| Ftm32MasterConst-18GazeboDetail |
| OLE1 |
File details come from the government source that posted it. Updated .