About this file

PD10WRGBGBEA34 Revision C dated 12 Dec 2011

View the file

Other files for this federal contract opportunity

Other files attached to B-1 Advanced Radar/Electronic Warfare Test Stations (ARTS) Synopsis, newest first.
File Type Posted
QA 17 Jan 12.doc DOC document
DWG 3203044 Sheet 21.pdf PDF
FA853311R31160______0004.pdf PDF
Q A 12 Jan 12.doc DOC document
QA 9 Jan 12.doc DOC document
Training Materials.pdf PDF
FA853311R31160______0003.pdf PDF
LCU_interlock info.pdf PDF
TMCR.pdf PDF
Attachment_6_Quantity_Ranges.doc DOC document
Attachment 1--legacy LRU blower_SCD pg16.pdf PDF
9579776_98752.pdf PDF
QA RFP.doc DOC document
Document request.doc DOC document
VDATS_Wrapper_Style_Guide.pdf PDF
FA853311R31160_C002_Data_Accession_List.pdf PDF
FA853311R31160_B005_Engineering_Change_Proposal.pdf PDF
FA853311R31160_C001_Request_for_Nomenclature.pdf PDF
FA853311R31160_C008_Computer_Software_Product_End_Items.pdf PDF
FA853311R31160_B-1-Weapon-System-Program-Security-Classification-Guide-Section-XIII.pdf PDF
FA853311R31160_A005_Engineering_Support_Data.pdf PDF
FA853311R31160_A004_Design_Review_Information_Package.pdf PDF
FA853311R31160_E002_Supplemental_Data_for_Provisioning.pdf PDF
FA853311R31160_C007_Calibration_Measurements_Requirements.pdf PDF
FA853311R31160_C006_Firmware_Support_Manual.pdf PDF
FA853311R31160_F001_Product_Drawings.pdf PDF
FA853311R31160_Attachment_5_Subcontractor_Consent_Form.doc DOC document
FA853311R31160_A006_Training_Materials.pdf PDF
FA853311R31160_A002_Test_Inspection_Report.pdf PDF
FA853311R31160_Attachment_3_Transmittal_Letter.doc DOC document
FA853311R31160_B006_Request_for_Deviation.pdf PDF
FA853311R31160_B003_Conference_Agenda.pdf PDF
FA853311R31160_E001_LMI_Data_Products.pdf PDF
FA853311R31160_D001_TMCR.pdf PDF
FA853311R31160_B-1-Weapon-System-Program-Security-Classification-Guide_Section-IX.pdf PDF
FA853311R31160_ARTSSOW.docx DOCX document
FA853311R31160_Attachment_1_FACTS_Sheet.pdf PDF
FA853311R31160_AFMC158.pdf PDF
Questions and Answers_14 Nov 2011.doc DOC document
B-1 Weapon System Program Security Classification Guide Section XIII.pdf PDF
B-1 Weapon System Program Security Classification Guide Section IX.pdf PDF
DD Form 254.pdf PDF
QA response to DRFP FA8533-11-R-31160.doc DOC document
Q A and Reminder--DRFP.doc DOC document
Information--DRFP.doc DOC document
L409C2011.pdf PDF
Q A DRFP.doc DOC document
ARTS SOW_30 Mar 11.pdf PDF
Draft of RFP Schedule.pdf PDF
PD10WRGBGBEA34 rev A_R3.pdf PDF
Show all 50

B-1 Advanced Radar/Electronic Warfare Test Stations (ARTS) Synopsis has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PD10WRGBGBEA34, Rev C

CAGE 98752

12 December 2011

PURCHASE DESCRIPTION (PD)

Advanced Radar/Electronic Warfare Test Station (ARTS)

The Revision C to the PD serves to incorporate changed pages:

And to add page 43A, continuation page.

Programmable voltage with over-voltage protection output through full range to its maximum limit.

Programmable current limit with over-current protection.

Front panel indication of output status for normal operation or fault occurrence.

Provide the amount of current draw via software to the test executive described in paragraph 3.2.6.2.

The ARTS shall provide, at a minimum, the AC power stimuli as described in Table 3-2 below. Table 3-2 provides the minimum performance parameters of the AC power stimuli that are required for power input to the LRUs listed in Table 2-1. Note that only one LRU will be tested at a time on ARTS. All specified parameters shall be verified at the ICA.

Parameter Requirement

AC1 Voltage (programmable) 0 to 230 Vrms Programmable Resolution 1 Vrms Voltage Accuracy ± 2.5 % of output voltage Frequency (programmable) 60 Hz to 400 Hz Programmable Resolution 1 Hz Frequency Accuracy ± 5 % Number of Phases 3-phase : ØA, ØB, ØC Programmable Phase

Resolution

1.0 degree

Programmable Phase Accuracy 1% per 100 Hz Max Current 10 A per phase Output Power 6900 VA

AC2 Voltage (programmable) 0 to 100 Vrms Programmable Resolution 1 Vrms Voltage Accuracy ± 5 % of output voltage Frequency (programmable) 60 Hz to 400 Hz Programmable Resolution 1 Hz Frequency Accuracy ± 5 % Number of Phases 3-phase : ØA, ØB, ØC Programmable Phase

Resolution

1.0 degree

Programmable Phase Accuracy 1% per 100 Hz Max Current 3.5 A per phase Output Power 1050 VA

Table 3-2 AC Power Stimulus

2.4 GHz processor (min)

B RAM (min) 80 GB Hard Disk Drive (min) – Each ARTS shall contain two (2) removable

HDDs; one for classified and one for non-classified material Display pointer control –mouse, trackball, or other device (PS/2 or USB) Keyboard – Standard 101/102 Key (min) (PS/2 or USB) Monitor – 19”, 256-color, 1152x864 resolution (min) Printer – 8 ppm (min) (USB or parallel) Ethernet Interface – data rate 100/1000 Mbps (min) Speakers – standard 2-speaker system CD/DVD-ROM – qty of one (1) Peripheral Interface Devices – Sufficient type and quantity of peripheral interface devices to support data/control bus with ATE instruments (ex: PCI-based IEEE-

488 CCA)

Video Graphics CCA – integrated (on motherboard) or auxiliary (i.e. PCIe, PCI, AGP, etc.) to support graphic requirements of ARTS.

USB Interface – min of 4 extra or vacant (not already used) USB ports

The main operator interface shall be the PC keyboard, display monitor, pointer control (mouse, trackball, etc.) and printer. This interface shall provide the operator interface for the normal on-station activities such as TPS integration, debug, test and UUT testing actions. This interface shall also provide the operator interface for ATE maintenance activities such as confidence testing, self-test, and calibration.

This operator terminal/interface shall be packaged in a mobile crate or on a mobile work stand to facilitate movement to different locations around the station. This mobility requirement is for operator convenience in performing manual intervention actions and troubleshooting during TPS integration and UUT testing.

3.3.2 Input Power Requirements. The primary power for the ARTS shall accommodate both 120/208 VAC ± 10% with 70 amperes per phase, and 277/480 VAC ± 10% with 56 amperes per phase, at 50/60 Hz ± 5%, 3-phase, 4-wire, wye-connected, with a separate safety ground. It shall be consistent with the requirements listed in MIL- PRF-28800F and MIL-STD-1332B, and subject to the examination and test methods noted therein, as specified in section 4.3.2. It shall be equipped with a master power ON/OFF switch and indicator, an emergency power shut down switch (located on the front panel) and an elapsed time indicator. It shall also contain a power-monitoring device to analyze input power parameters and provide operator notification if an out of tolerance condition is detected. Automatic and operator initiated shutdown shall provide an orderly, sequential system shutdown to preclude ATE or UUT damage and shall not degrade the ATE hardware or software. All facility power inputs and internal power supplies shall be equipped with circuit breakers to minimize damage to ATE assets and UUTs.

The ARTS shall provide six 115 VAC, 15A convenience receptacles located on the front of the station to provide power for general purpose electrical equipment.

PD10WRGBGBEA34 Rec C Face page
PD10WRGBGBEA34 Rev C Page 11
PD10WRGBGBEA34 Rev C Page 43 and 43A