PD_Rev_C.pdf

PDF 27 KB Posted

Attached to
B-1 Advanced Radar/Electronic Warfare Test Stations (ARTS) Synopsis
Solicitation number
FA8533-11-R-31160
Issued by

About this file

PD10WRGBGBEA34 Revision C dated 12 Dec 2011

View the file

Other files

File Type Posted
Drawing 3202300 Sheets 24 25.pdf PDF
QA 17 Jan 12.doc DOC document
FA853311R31160______0004.pdf PDF
DWG 3203044 Sheet 21.pdf PDF
PD10WRGBGBEA34_Rev_E.doc DOC document
Q A 12 Jan 12.doc DOC document
QA 9 Jan 12.doc DOC document
FA853311R31160______0003.pdf PDF
Training Materials.pdf PDF
PD10WRGBGBEA34_Rev_D.pdf PDF
QA 6 Jan 12.doc DOC document
LCU_interlock info.pdf PDF
LCU_fitting_info.pdf PDF
QA 22 Dec 11.doc DOC document
QA 16 Dec 11.doc DOC document
FA853311R31160______0002.pdf PDF
Attachment_6_Quantity_Ranges.doc DOC document
TMCR.pdf PDF
9626025_98752.pdf PDF
Attachment 1--legacy LRU blower_SCD pg16.pdf PDF
9579776_98752.pdf PDF
9579777_98752.pdf PDF
QA RFP.doc DOC document
Document request.doc DOC document
Wrapper Common SRS 20110405.pdf PDF
FA853311R31160______0001.pdf PDF
VDATS_Wrapper_Style_Guide.pdf PDF
VDATS_Wrapper_Style_Guide.pdf PDF
FA853311R31160_E001_LMI_Data_Products.pdf PDF
FA853311R31160_B004_Conference_Minutes.pdf PDF
FA853311R31160_App-C.doc DOC document
FA853311R31160_A003_Technical_Report-Study_Services.pdf PDF
FA853311R31160_C003_Computer_Software_Flowchart.pdf PDF
FA853311R31160_C002_Data_Accession_List.pdf PDF
FA853311R31160_B005_Engineering_Change_Proposal.pdf PDF
FA853311R31160_A006_Training_Materials.pdf PDF
FA853311R31160_A002_Test_Inspection_Report.pdf PDF
FA853311R31160_C001_Request_for_Nomenclature.pdf PDF
FA853311R31160_B-1-Weapon-System-Program-Security-Classification-Guide-Section-XIII.pdf PDF
FA853311R31160_C008_Computer_Software_Product_End_Items.pdf PDF
FA853311R31160_A004_Design_Review_Information_Package.pdf PDF
FA853311R31160_A005_Engineering_Support_Data.pdf PDF
FA853311R31160_Attachment_3_Transmittal_Letter.doc DOC document
FA853311R31160_E002_Supplemental_Data_for_Provisioning.pdf PDF
FA853311R31160_B006_Request_for_Deviation.pdf PDF
FA853311R31160_B003_Conference_Agenda.pdf PDF
FA853311R31160.RTF RTF text file
FA853311R31160_C007_Calibration_Measurements_Requirements.pdf PDF
FA853311R31160_C006_Firmware_Support_Manual.pdf PDF
FA853311R31160_Appendix_B_13Oct11_7pages.doc DOC document
Show 40 more

Latest 50 of 87 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PD10WRGBGBEA34, Rev C

CAGE 98752

12 December 2011

PURCHASE DESCRIPTION (PD)

Advanced Radar/Electronic Warfare Test Station (ARTS)

The Revision C to the PD serves to incorporate changed pages:

And to add page 43A, continuation page.

Programmable voltage with over-voltage protection output through full range to its maximum limit.

Programmable current limit with over-current protection.

Front panel indication of output status for normal operation or fault occurrence.

Provide the amount of current draw via software to the test executive described in paragraph 3.2.6.2.

The ARTS shall provide, at a minimum, the AC power stimuli as described in Table 3-2 below. Table 3-2 provides the minimum performance parameters of the AC power stimuli that are required for power input to the LRUs listed in Table 2-1. Note that only one LRU will be tested at a time on ARTS. All specified parameters shall be verified at the ICA.

Parameter Requirement

AC1 Voltage (programmable) 0 to 230 Vrms Programmable Resolution 1 Vrms Voltage Accuracy ± 2.5 % of output voltage Frequency (programmable) 60 Hz to 400 Hz Programmable Resolution 1 Hz Frequency Accuracy ± 5 % Number of Phases 3-phase : ØA, ØB, ØC Programmable Phase

Resolution

1.0 degree

Programmable Phase Accuracy 1% per 100 Hz Max Current 10 A per phase Output Power 6900 VA

AC2 Voltage (programmable) 0 to 100 Vrms Programmable Resolution 1 Vrms Voltage Accuracy ± 5 % of output voltage Frequency (programmable) 60 Hz to 400 Hz Programmable Resolution 1 Hz Frequency Accuracy ± 5 % Number of Phases 3-phase : ØA, ØB, ØC Programmable Phase

Resolution

1.0 degree

Programmable Phase Accuracy 1% per 100 Hz Max Current 3.5 A per phase Output Power 1050 VA

Table 3-2 AC Power Stimulus

2.4 GHz processor (min)

B RAM (min) 80 GB Hard Disk Drive (min) – Each ARTS shall contain two (2) removable

HDDs; one for classified and one for non-classified material Display pointer control –mouse, trackball, or other device (PS/2 or USB) Keyboard – Standard 101/102 Key (min) (PS/2 or USB) Monitor – 19”, 256-color, 1152x864 resolution (min) Printer – 8 ppm (min) (USB or parallel) Ethernet Interface – data rate 100/1000 Mbps (min) Speakers – standard 2-speaker system CD/DVD-ROM – qty of one (1) Peripheral Interface Devices – Sufficient type and quantity of peripheral interface devices to support data/control bus with ATE instruments (ex: PCI-based IEEE-

488 CCA)

Video Graphics CCA – integrated (on motherboard) or auxiliary (i.e. PCIe, PCI, AGP, etc.) to support graphic requirements of ARTS.

USB Interface – min of 4 extra or vacant (not already used) USB ports

The main operator interface shall be the PC keyboard, display monitor, pointer control (mouse, trackball, etc.) and printer. This interface shall provide the operator interface for the normal on-station activities such as TPS integration, debug, test and UUT testing actions. This interface shall also provide the operator interface for ATE maintenance activities such as confidence testing, self-test, and calibration.

This operator terminal/interface shall be packaged in a mobile crate or on a mobile work stand to facilitate movement to different locations around the station. This mobility requirement is for operator convenience in performing manual intervention actions and troubleshooting during TPS integration and UUT testing.

3.3.2 Input Power Requirements. The primary power for the ARTS shall accommodate both 120/208 VAC ± 10% with 70 amperes per phase, and 277/480 VAC ± 10% with 56 amperes per phase, at 50/60 Hz ± 5%, 3-phase, 4-wire, wye-connected, with a separate safety ground. It shall be consistent with the requirements listed in MIL- PRF-28800F and MIL-STD-1332B, and subject to the examination and test methods noted therein, as specified in section 4.3.2. It shall be equipped with a master power ON/OFF switch and indicator, an emergency power shut down switch (located on the front panel) and an elapsed time indicator. It shall also contain a power-monitoring device to analyze input power parameters and provide operator notification if an out of tolerance condition is detected. Automatic and operator initiated shutdown shall provide an orderly, sequential system shutdown to preclude ATE or UUT damage and shall not degrade the ATE hardware or software. All facility power inputs and internal power supplies shall be equipped with circuit breakers to minimize damage to ATE assets and UUTs.

The ARTS shall provide six 115 VAC, 15A convenience receptacles located on the front of the station to provide power for general purpose electrical equipment.

PD10WRGBGBEA34 Rec C Face page
PD10WRGBGBEA34 Rev C Page 11
PD10WRGBGBEA34 Rev C Page 43 and 43A

File details come from the government source that posted it. Updated .